ELECTRIC MOTOR SIZING CHART
up to 25’
6 hp 12 hp 20 hp 40 hp 70 hp 100 hp
2.5 kW 5.1 kW 8.5 kW 17 kW 29.75 kW 42.5 kW
70 amps 106 amps 118 amps 167 amps 275 amps 295 amps
36 vdc 48 vdc 72 vdc 108 vdc 108 vdc 144 vdc
3 4 6 9 9 12
.550 to 1.0 kW 1.1 to 2.0 kW 1.9 to 2.75 kW 9.6 to 14 kW6.6 to 9.0 kW3.8 to 5.5 kW
1500 RPM 1500 RPM 1500 RPM 1500 RPM 1500 RPM 1500 RPM
1800 RPM 1800 RPM 1800 RPM 1800 RPM 1800 RPM 1800 RPM
EP-600
Boat Size 20’-35’
EP-1200
25’-40’
EP-2000
32’-48’
EP-4000
38’-56’
EP-7000
50’-75’
EP-10000
Horsepower diesel equivalency
Kilowatts (maximum fulll power from batteries)
Amps (maximum)
Battery voltage DC
Batteries (minimum required 12 vdc)
Batteries AGM amp/hours1. Day Sailboat2. Cruising Sailboat
Battery Charger (number and size)
1. Day Sailboat2. Continuous Cruise (50% throttle)
3. Continuous Cruise (75% throttle)
Generator size AC or DC for continuous hybrid cruising (50% throttle provides 60% of hull speed)
Generator size AC or DC for continuous hybrid cruising (75% throttle provides 80% of hull speed)
RPM Setting, Full Throttle***
RPM Setting, Power Boost
100 to 200 150 to 220 150 to 220 200 to 240 200 to 240 240
200 to 220 200 to 220 200 to 240 220 to 440* 220 to 440* 220-480*
1 @ 36 vdc 1 @ 48 vdc 1 @ 72 vdc 3 @ 36 vdc 3 @ 36 vdc 4 @ 36 vdc
1 @ 20 amp 1 @ 30 amp 1 @ 30 amp 3 @ 30 amp 3 @ 70 amp 4 @ 80 amp
1 @ 20 amp 1 @ 40 amp 1 @ 60 amp 1 @ 70 amp 3 @ 90 amp 8 @ 80 amp**
1.2 to 2.0 kW 2.5 to 3.5 kW 4.2 to 6.5 kW 8.5 to 13 kW 15 to 20 kW 15 to 25 kW
Elco Electric Motor
Applies to displacement boats only
patent pending877.411.ELCO (3526) | elcomotoryachts.com
* Two banks of batteries in parallel. ** This is a combination of chargers in series parallel in order to increase the current rating, the voltages stay the same. ***RPM default settings, custom settings are available from the factory on special order, or field settable by a trained technician. ˇ Performance is based on battery power only - Run time can be continuous with Generator.