electric on/off & control valves · 2018-02-14 · 1 each for open and close (spdt 250v ac/10a...
TRANSCRIPT
Sealed by O-ring in all interfaces, and double o-ring sealing for IP68(option)
EP type grease, maintenance free service for a long period time
Difference size depending on actuator torque, and knob on hand wheel for easy operation
Precisely machined double worm gear c/w minimum back-lash, low noise, high output torque
Provided by double worm gearing to keep position of valve unchanged against reverse torque fromvalve
Hard anodized Aluminum casting and external epoxy powder coated against severe industrialenvironment.
- To prevent over run of travel angle when limit switch fails
- Standard 2 X PF 3/4 (Max 1 ) cable entry for variouscable gland
- Auto/Manual switch able lever hand wheel engagement foremergency manual operating
- Drive force automatically resorted by motor start unlesslever padlock to prevent it
- Easy machining for step adaption- Standard ISO5211 mounting base (F03 ~ F16)for easy
mounting on valve- Large size drive bushing accept large valve stem
- Specially designed induction motor generate high startingtorque and high efficiency equip with thermal protector toprevent damage from over heating
- Anti-condensation equip with thermal
- Cover bolts are captive type designed to prevent loosing duringmaintenance or installation
- All external bolts are stainless steel for rust prevention
- To protect actuator from damage caused by overload from the driven valve over the whole travel
- High resolution potentiometer and precisely machined gearingare directly engaged with drive shaft to feedback continuousposition of valve
- Directly engaged with driving shaft to set accurate position ofvalve
- 1 ea for each travel end (open/close)- Optional Extra Limit Switches (Max 4 ea for each end)
- Large size position directly engaged with driving shaft for bettervisibility from a distance
- Spring loaded underneath keeps set position unchanged unlessused move it
ModelRatedtorque
Nm
Operatingtime
50/60Hz90
Maxboresizemm
Powerconsum-
ptionWatts
Motorinsulation
class
Rated current (A)50/60Hz
1Phase 3Phase110V 220V 380V 440V Kg
No ofhandleturns90
Weight
ATM0040
ATM0080
40
80
20/14
20/14
17
17
15
15
F
F
0.5
0.95/1.05
0.3
0.50/0.55
OK
OK
NA
NA
9
10
5
7
ATM0100
ATM0160
ATM0240
ATM0350
ATM0500
ATM0800
ATM1100
100
160
240
350
500
800
1100
21/18
26/22
26/22
31/26
31/26
39/32
20/14
23
27
27
42
42
52
52
15
40
40
40
90
180
180
F
F
F
F
F
F
F
0.95/1.05
1.60/1.70
1.62/1.72
1.72/1.80
3.60/3.90
3.80/4.20
3.90/4.30
0.50/0.55
0.85/0.90
0.87/0.92
0.92/0.95
1.30/1.60
2.05/2.20
2.15/2.30
NA
0.30/0.30
0.32/0.32
0.32/0.32
0.52/0.56
0.82/0.88
0.84/0.90
NA
0.30/0.32
0.32/0.34
0.32/0.35
0.55/0.58
0.82/0.85
0.84/0.88
10
12
12
14
14
17
17
7
15
15
20
20
25
25
EnclosureMain Power supplyControl power supplyDuty cycle (on-off)Duty cycle (modulating)MotorLimit switchesTorque switchesStall protection/set temperatureTravel anglePosition indicatorManual overrideSelf lockingMechanical stopperHeaterCable entriesLubricationTerminal blockAmbient temperatureAmbient humidityAnti vibrationExternal coating
Weather poof IP67, NEMA4 and 4X,O-ing sealed (ATM0060 IP66)110/220V AC / 1Ph / 50 / 60Hz, 380/440/VAC/9Ph / 50 / 60 / Hz 10%
110/220V AC / 1Ph / 50 / 60 Hz 10%S2, 20 ~ 50% Max 10Min ~ 30Min
S4, 30 ~ 50%, 300 ~ 1200 start/hourSquirrel caged induction motor
1 each for open and close (SPDT 250V AC/10A rating)1 each for open and close (SPDT 250V AC/10A rating except for ATM0060,0100
Built in thermal protection, High 150 5 , Low 97 1590 5 ( ° 100 )
Plate with indication arrowDe-clutchable (except for ATM0060)
Provided by double worm gearing (no brake)(except for ATM0060)1 each for each travel end (open and close),(external adjustable(ATM0060)
5W (110/220V AC) for anti-condensation2 X PF 3/4 TAP (except for ATM30,60, 2 X PT 1/2 TAP)
EP type greaseScrew and lever push type (spring loaded)
-20 ~ 7090% RH Max (Non-Condensing)XYZ 10g, 02 ~ 34Hz, 30 minutes
Dry power (Polyester)
ATM1500
(ATM0500+AG1/3)
ATM2000
(ATM0800+AG1/3)
ATM3000
(ATM1100+AG1/3)
1500
2000
3000
93/78
117/97
117/97
78
78
78
180
180
180
F
F
F
3.60/3.90
3.80/4.20
3.90/4.30
1.30/1.60
2.05/2.20
2.15/2.30
0.52/0.56
0.82/0.88
0.84/0.90
0.55/0.58
0.82/0.85
0.84/0.88
42
52
52
42
52
52
Symbol
DOM
EX
WT
ALS
ATS
EXT
SV
Description
Dome indicator
Explosion proof (Ex d II B(c) T4)
Watertight (IP68)
Auxiliary limit switches (Max 4 for each travel end)
Auxiliary torque switches (Max 4 for each travel end)
Extended travel angle (up to 120°,135°,180°, 270°)
Variation in torque and operating speed
Remark
Except for ATM0060
Except for ATM0060
Except for ATM0060
Except for ATM0060,ATM0100
Except for ATM with gear box
Please consult before order
PK
CT
RPC
Signal
Configuration
RPD
Potentiometer kit (output signal : 0 ~ 1Kohm)
Current transmitter (output : 4 ~ 20mA)
Remote position controller(by input and output signal)
Remote position controller(by input and output signal) with display (LCD)
In put: 4~20mA, 0~10 VDC, 2~10 VDC, 1~5VDC, 0~5VDC
Out put: 4~20mA, 0~10 VDC, 2~10 VDC, 1~5VDC, 0~5VDC
Refer to below signal configuration
LP1
LP2
LM1
LM2
LD
Local position control (Remote/Open/Step/Close without lamps)
Local position control (Remote/Local, Open/Step/Close with lamps)
Integrated motor starter without local control switches (On ~ off only)
Local position control (Remote/Local, Open/Step/Close with lamps)with integrated
Motor starter (Mechanical)
Local position control ((Remote/Local, Open/Stop, Close with lamps)
with Integrated motor starter, monitoring relays)
1) Type : Rotary switch2) Selecting and control:4 steps (Remote/Open/Stop/Close)for on-off only3) No local display
1) Type : Rotary switches with position lamps2) Operating - Selector switch : Remote (with Yellow lamp), Local(with Red lamps)
- Control switch : Open/Stop/Close- Local display : Green lamp at open position, Red lamp at close position
- Integrated 2 magnetic contactors for open and close without control device
1) Type : Rotary switches with position lamps
2) Operating- Selector switch:Remote(With Yellow lamp),Local(With Red lamp)- Control Switch:Open/Step/Close- Integrated 2 magnetic contactors for Open/Close,Power source for control
3) Options for remote monitoring and control- PK(0~1Kohm),CT(4~20mA output signal),RPC(or RPD) for 4-20mA input/output Signal
- Combination of electronic positioner(4~20mA input,proportional control)- Auto-calibration provides the most convenient to user without complicated
set in field
- All adjustable point are parameterized, and big size LCD display panel for indicating current status
1) Type : 2 Magnetic sensors (Rotary type)with status monitoring lamps
2) Operating : Selector switch-Off,Local,Remote(Off : Stop or turn off) Control switch-Local open,Close
3) Local display : Remote/Local,open,close,over torque
4) Remote control- Type : 500V Opto-lsolated, DC24V,AC110 both- Command : Open/Close/Stop/ESD(Emergency shut down)- Output : Relay and direct from switch(Full Open/Full Close)
5) Options- CT(Current transsmitter) : Both sink/Source type,output 4-20mA- RPC(or RPD)for 4-20mA input andoutput signal- Profuse communication : 1.5Mbps, 1 channel,SPC-3
RPC -
CT is basically R/I converter as signal transmitter after positioning of actuator.Potentiometer detects current position of actuator as resistance(0~1Kohm) and CT convert it to currentsignal(4-20mA) and send it back to main controller.Generally, it transmits 4mA at fully closed position, and 20mA at fully open position
1) Model: CT-01-A2) Power : 110V/220VAC 10% 50/60Hz 4VA Max(changeable by DIP switch)3) Output signal: 4~2-mA DC4) Load resistance: 750Ohm Max.5) Resolution : Min. 1 / 10006) Position conversion accuracy : 0.5 ~ 1.5%(Depending on mounting accuracy)7) Ambient temperature: -10oC ~ +60oC8) Ambient humidity: 90% RH Max (Non-condensate)9) Dielectric strength: 1500V AC 1Min (Input to output, Power to Ground)
10) Insulation resistance: Min. 500VDC 30Mohm11) Vibration & Shock (X, Y, Z): 10g(6g based on RMF, Frequency: 0.2 ~ 34Hz, 30Min12) LED signal : Refer to LED signal indication
1) Zero settingPut actuator 50% open position by manual, supply close command from control panel.When actuator fully close, adjust Zero volume until getting correct signal 4mA.
2) Span settingRepeat same procedure as Zero setting, but gained signal must be 20mA adjusting Span volume.
3) Repeat above procedure 2~3 times to get correct signal
SpanOpenSetting
ZeroCloseSetting
ZERO CLOSE SETTING
SPAN OPEN SETTING
POWER ON
Indication on PCB
O POW
O FAU
LED
Blue on
Yellow Flicker
Meaning
Power on
Failure in either PK. CT or Wiring
All electrical wiring is done by quick plug-in connectors.
OPTION NAME
MODEL
X mm
Y mm
Z mm
0100
428
172
220
0160/0240
508
229
259
0350/0500
527
244
288
0800/1100
550
284
313
1500
538
293
506
2000/3000
550
312
531
LP2/LM2
OPTION NAME
MODEL
X mm
Y mm
Z mm
ATM0100
316
172
220
CTOPTION NAME
MODEL
X mm
Y mm
Z mm
ATM0100
340
190
220
RPC
OPTION NAME
MODEL
X mm
Y mm
Z mm
0100
419
172
220
0160/0240
499
229
259
0350/0500
518
244
288
0800/1100
541
284
313
1500
529
293
506
2000/3000
541
312
531
LP4/LD1
OPTION NAME
MODEL
X mm
Y mm
Z mm
0100
428
172
220
0160/0240
508
229
259
0350
527
244
288
BP
OPTION NAME
MODEL
X mm
Y mm
Z mm
0160/0240
517
284
259
0350/0500
536
284
288
0800/1100
559
284
313
1500
547
284
506
2000/3000
559
284
531
LD2
AC 110/220V, 50/60Hz, 1Ph(On-off)
AC 380/480V, 50/60Hz, 3Ph(On-Off) AC 110/220V, 50/60Hz, 3Ph(Modulating:RPC)
ATM0040 ATM0080
ATM0080(3Ph) ATM0080(RPC)
AC 110/220V, 50/60Hz, 1Ph(On-off)
AC 110/220V, 50/60Hz, 1Ph(On-off)
AC 380/480V, 50/60Hz, 3Ph(On-Off)
ATM0100 ATM0100(RPC)
ATM0100(3Ph)
AC 110/220V, 50/60Hz, 3Ph(Modulating:RPC)
CLS : Close Limit Switch (250VAC 10A)OLS : Open Limit Switch (250VAC 10A)ACLS : Aux. Close Limit Switch (250VAC 10A)AOLS : Aux. Open Limit Switch (250VAC 10A)ACTS : Aux. Close Torque Switch (250VAC 10A)AOTS : Aux. Open Torque Switch (250VAC 10A) TP : THERMAL PROTECTOR (250VAC 15A OPTION)* Each actuator should be powered through its ownindividual switch or relay contacts to prevent cross feedvetween two or more actuators.
AC 110/220V, 50/60Hz, 1Ph(On-off)
AC 380/480V, 50/60Hz, 3Ph(On-Off)
ATM0160~3000 ATM0160~3000(RPC)
ATM0160~3000(3Ph)
AC 110/220V, 50/60Hz, 3Ph(Modulating:RPC)
CLS : Close Limit Switch (250VAC 10A)OLS : Open Limit Switch (250VAC 10A)ACLS : Aux. Close Limit Switch (250VAC 10A)AOLS : Aux. Open Limit Switch (250VAC 10A)ACTS : Aux. Close Torque Switch (250VAC 10A)AOTS : Aux. Open Torque Switch (250VAC 10A) TP : THERMAL PROTECTOR (250VAC 15A OPTION)* Each actuator should be powered through its ownindividual switch or relay contacts to prevent cross feedvetween two or more actuators.
AC 110/220V, 50/60Hz, 1Ph(CT)
AC 380/480V, 50/60Hz, 3Ph(CT)
ATM0100(CT CARD)
ATM0160~3000(CT CARD)
ATM0160~3000(CT CARD)
AC 110/220V, 50/60Hz, 1Ph(CT)
CLS : Close Limit Switch (250VAC 10A)OLS : Open Limit Switch (250VAC 10A)ACLS : Aux. Close Limit Switch (250VAC 10A)AOLS : Aux. Open Limit Switch (250VAC 10A)ACTS : Aux. Close Torque Switch (250VAC 10A)AOTS : Aux. Open Torque Switch (250VAC 10A) TP : THERMAL PROTECTOR (250VAC 15A OPTION)* Each actuator should be powered through its ownindividual switch or relay contacts to prevent cross feedvetween two or more actuators.
Water Distribution pipes.Industrial Cleaning Machined.SterilizersAir Conditioners, Water FiltersMedical Equipments, Vacuum Packing
Valve Size
Actuator Model
Actuator Type
Electrical
Output Torque
Operating Time
Operating Type
Rotating Angle
Fluid Temperature
Pressure Range
Body Material
ATM01
Electric
AC 95 - 230V (Free Volt)
2Nm
5~7Sec
ON/OFF
90 3
-20 ~ 100
10Kgf/cm2
15A(1/2 ) 20A(3/4 ) 25A(1 )
ModelATM01-15S1ATM01-20S1ATM01-25S1
Size1/23/41
15A20A25A
535353
646464
74.574.578.5
556376
151520
A A1 H L D(mm)
SUS304 / BODY SUS304 / BALL PTFE / SEAT
Water Distribution pipes.Industrial Cleaning Machines.Sterilizers, BoilersAir Conditioners , Water FiltersMedical Equipments, Vacuum Packing
Valve Size
Actuator Model
Actuator Type
Electrical
Output Torque
Operating time
Operating Type
Rotating Angle
Fluid Temp
Pressure Range
Body Material
ATM0040
Electric
110V AC,220V AC,380V AC, 440V AC
40Nm
20/50Hz, 14/60Hz
ON/OFF, Modulating
90 3
-10 ~ 90
10Kgf/cm2
10A(3/8 ) 15A(1/2 ) 20A(3/4 ) 25A(1 ) 32A(1-1/4 ) 40A(1-1/2 50A(2 )
ModelATM0040-10S1ATM0040-15S1ATM0040-20S1ATM0040-25S1ATM0040-32S1ATM0040-40S1ATM0040-50S1
10A15A20A25A32A40A50A
Size3/81/23/41
1-1/41-1/2
2
113.5113.5113.5113.5113.5113.5113.5
A121.8121.8121.8121.8121.8121.8121.8
A1188200220224230246245
H45
56.559717882
100
L7.7
9.2
12.5
15
20
25
32
D(mm)
SUS316 / BODY SUS316 / BALL PTFE / SEAT
Water Distribution pipesIndustrial Cleaning MachinesSterilizers, BoilersAir Conditioners , Water FiltersMedical Equipments, Vacuum Packing
Valve Size
Actuator Model
Actuator Type
Electrical
Output Torque
Operating Type
Rotating Angle
Fluid Temp
Pressure Range
Body Material
Operating time
ATM0040
Electric
110V AC,220V AC,380V AC, 440V AC
60Nm
ON/OFF, Modulating
90 3
-10 ~ 90
10Kgf/cm2
10A(3/8 ) 15A(1/2 ) 20A(3/4 ) 25A(1 ) 32A(1-1/4 ) 40A(1-1/2 50A(2 )
ModelATM0040-08S3ATM0040-10S3ATM0040-15S3ATM0040-20S3ATM0040-25S3ATM0040-32S3ATM0040-40S3ATM0080-50S3
08A10A15A20A25A32A40A50A
Size1/43/81/23/41
1-1/41-1/2
2
113.5113.5113.5113.5113.5113.5113.5160
A121.8121.8121.8121.8121.8121.8121.8121
A1205205205207216227231218
H6060657585
100110130
L0810152025324050
D(mm)
SUS316 / BODY SUS316 / BALL PTFE / SEAT
ATM0080
100Nm
21/50Hz,
18/60Hz20/50Hz, 14/60Hz
Water distribution pipesIndustrial cleaning machinesSterilizers, Boilers Air conditioners, Water filtersMedical equipments, Vacuum packingFood & Beverage linesVacuum distribution pipes
Valve Size
Actuator Model
Actuator Type
Electrical
Rotating Angle
Operating Type
Fluid Temp
Rating
Body Material
Electric
110V AC,220V AC,380V AC, 440V AC
90 3
ON/OFF, Modulating
-10 ~ 90 (-10 ~ 150 )
JIS10K (20K) (40K) ANSI150# (300#) (600#)
SUS304 (SUS316)/Body SUS304 (SUS316)/Ball PTFE (GRAPHITE)/Seat
( ) Option
15A ~ 350A
ATM0040 ~ ATM3000
Model mm inch A A1 H L G C D t N-H
JIS10K RF (mm)Size
ATM0040-15F 15A 1/2 113.5 121.8 233 108 52 70 95 12 4-15ATM0040-20F 20A 3/4 113.5 121.8 236 117 58 75 100 14 4-15ATM0040-25F 25A 1 113.5 121.8 245 127 70 90 125 14 4-19ATM0040-32F 32A 1-1/4 113.5 121.8 248 140 80 100 135 16 4-19ATM0040-40F 40A 1-1/2 113.5 121.8 269 165 85 105 140 16 4-19ATM0080-50F 50A 2 160 121 256 178 100 120 155 16 4-19ATM0160-65F 65A 2-1/2 338 229 406 190 120 140 175 18 4-19ATM0160-80F 80A 3 38 229 450 203 130 150 185 18 8-19ATM0350-100F 100A 4 357 244 492 229 155 175 210 18 8-19ATM0500-125F 125A 5 357 244 533 356 185 210 250 20 8-23ATM0500-150F 150A 6 357 244 578 394 215 240 280 22 8-23ATM1100-200F 200A 8 357 284 700 457 265 290 330 22 12-23ATM2000-250F 250A 10 357 293 920 533 325 355 400 24 12-25ATM3000-300F 300A 12 357 293 1300 610 375 400 445 24 16-25ATM3000-350F 350A 14 357 293 1350 686 415 445 490 26 16-25
Water distribution pipesIndustrial cleaning machinesSterilizers, Boilers Air ventilationMedical equipments, Vacuum packingAir ventilation systems
Valve Size
Actuator Model
Actuator Type
Electrical
Rotating Angle
Operating Type
Fluid Temp
Rating
Body Material
Electric
110V AC,220V AC,380V AC, 440V AC
90 3
ON/OFF, Modulating
-10 ~ 90 (-10 ~ 150 )
JIS10K Wafer ANSI150# Wafer
FC (SUS304)/Body SUS304 (SUS316)/Disc EPDM (MTFE)/Seat
( ) Option
40A ~ 600A
ATM0040 ~ ATM3000
Model mm inch
JIS10K WAFER (mm)Size
ATM0040-40BF 40A 1-1/2 113.5 121.8 397 58 33 40 86ATM0040-50BF 50A 2 113.5 121.8 412 66.5 43 52 105ATM0080-65BF 65A 2-1/2 160 121 324 71 46 65 114ATM0080-80BF 80A 3 160 121 346 83 46 80 129ATM0100-100BF 100A 4 258 172 528 95 52 100 155ATM0160-125BF 125A 5 338 229 597 110 56 125 180ATM0240-150BF 150A 6 338 229 624 124 56 150 207ATM0350-200BF 200A 8 357 244 740 163 60 198 260ATM0500-250BF 250A 10 357 244 850 227 68 248 331ATM0600-300BF 300A 12 357 244 905 252 78 298 377ATM0800-350BF 350A 14 380 284 968 271 78 327 416ATM1100-400BF 400A 16 380 284 1080 343 102 387 475ATM1500-450BF 450A 18 357 293 1350 366 114 438 535ATM2000-500BF 500A 20 357 293 1490 421 127 477 590ATM3000-600BF 600A 24 357 293 1640 493 154 560 695
A A1 H H1 L d D