X NAME NAME xxxxc- xxx. dgn x: 1 GENERAL NOTES ELECTRICAL INDEX MDB ELECTRICAL LEGEND SYMBOL DESCRIPTION SUB DISTRIBUTION BOARD MDB (MAIN DISTRIBUTION BOARD) ELECTRICAL OUTLET, 13AMP, 220V, 50HZ STEEL FRAME PROTECTION CEILING FAN REGULATOR CEILING FAN EXHAUST FAN EMERGENCY EXIT SIGN & LIGHT, CADMIUM BATTERY BACKUP WITH BATTRY BACKUP FOR 90min, 220V,50Hz INDOOR LIGHT 220V, 50Hz, 36W, WATER PROOF R ELECTRICAL SWITCH, 10A, 220V, 50HZ, BY 2 ELECTRICAL SWITCH, 10A, 220V, 50HZ EXIT x x E-001 NAME 2 ELECTRI CAL LEGEND, GENERAL NOTES, AND I NDEX ELECTRICAL SWITCH, 10A, 220V, 50HZ, THREE WAY WATER, SPACE HEATER & AIR CONDITIONING ELECTRICAL POINT OF CONNECTION, 220V, 50 Hz OUTDOOR LIGHT 220V,50Hz,400W WEATHER PROOF, 100m OUTWARD DISTANCE 120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS, 72W, WITH COVER AND EMERGENCY BATTERY PACK 120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS, 72W, WITH COVER 120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS 72 W, WEATHER PROOF COVER (60X60) cm, ELECTRICAL MANHOLE, SEE SHEET E-503 FOR DETAIL GROUND ROD, SEE SHEET E-502 FOR DETAIL AIR TERMINAL FOR LIGHTNING PROTECTION SYSTEM SEE SHEET E-503 FOR DETAIL DOWN CONDUCTOR FOR LIGHTNING PROTECTION SYSTEM, SEE SHEET E-504 FOR CONNECTION SCHEME ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE 2005 NEC. LIGHTING SWITCHES, CEILING FAN REGULATORS AND EXHAUST FAN SWITCHES SHALL BE MOUNTED AT 1.2m ABOVE FINISHED FLOOR LEVEL AND 10cm FROM DOOR OPENING. ALL EXTERNAL ELECTRICAL SOCKETS SHALL BE MOUNTED AT 60cm ABOVE FINISHED GRADE, HAVE GFCI PROTECTION AND A WEATHER PROOF COVER. MINIMUM WIRE SIZE FOR POWER AND LIGHTING SHALL BE 4mm COPPER. OUTLETS IN BATHROOMS SHALL BE MOUNTED AT 1.2m ABOVE FINISHED FLOOR LEVEL. ALL OTHER OUTLETS SHALL BE MOUNTED AT 0.45m ABOVE FINISHED FLOOR LEVEL. OUTLETS SHALL BE PROTECTED BY GROUND FAULT CIRCUIT INTERUPTER (GFCI) IN BATHROOMS AND WET AREAS. SWITCHED OUTLETS FEEDING A/C UNITS SHALL BE MOUNTED IN ACCORDANCE WITH THE INDOOR FAN/COIL UNITS REQUIREMENT. DISTRIBUTION BOARDS SHALL BE MOUNTED AT 1.4m ABOVE FINISHED FLOOR LEVEL. THE MULTICORE CABLE USED SPECIFICATIONS ARE: A. COPPER CONDUCTOR B. PVC INSULATION C. PVC FILTER D. PVC OUTER SHEATH E. MAXIMUM WORKING TEMPERATURE IS 75^C THE SINGLE CORE CABLE USED SPECIFICATIONS ARE: A. COPPER CONDUCTOR B. PVC INSULATION C. MAXIMUM WORKING TEMPERATURE IS 75^C ALL PANEL BOARDS SHALL BE LISTED. INSTALL EMERGENCY EXIT SIGNS IN ARABIC WITH INTERNATIONAL SYMBOLS OVER PRIMARY EXIT FIRE ROUTES ALL CONDUCTORS AND TRANSFORMER WINDINGS SHALL BE COPPER. ALL CONDUIT SHALL BE EXPOSED METALLIC AND AND THE MINIMUM SIZE IS 16mm. UNDERGROUND CABLE MUST BE ARMOURED IF NOT INSTALLED IN PVC CONDUIT. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 E-001 ES101 EG101 EG102 EG103 EL101 EL102 EL103 EL104 EL105 EP101 EP102 EP103 EP104 EP105 EP106 EP107 EP108 EP109 E-501 E-502 E-503 E-504 E-505 E-601 E-602 E-603 E-604 E-605 E-606 E-607 E-608 E-609 ELECTRICAL LEGEND, GENERAL NOTES, AND INDEX EXAMPLE ELECTRICAL SITE PLAN MAIN BUILDING GROUNDING PLAN MAIN BUILDING LIGHTNING PROTECTION PLAN RECEPTION BUILDING GROUNDING PLAN GROUND FLOOR LIGHTING PLAN FIRST FLOOR LIGHTING PLAN ROOF FLOOR LIGHTING PLAN RECEPTION BUILDING GROUND FLOOR LIGHTING PLAN RECEPTION BUILDING ROOF FLOOR LIGHTING PLAN GROUND FLOOR POWER PLAN FIRST FLOOR POWER PLAN ROOF FLOOR POWER PLAN RECEPTION BUILDING POWER PLAN GUARD TOWER LIGHTING AND POWER PLAN GROUND FLOOR EQUIPMENT POWER PLAN FIRST FLOOR EQUIPMENT POWER PLAN ROOF FLOOR EQUIPMENT POWER PLAN RECEPTION BUILDING EQUIPMENT POWER PLAN ELECTRICAL DETAILS I ELECTRICAL DETAILS II ELECTRICAL DETAILS III ELECTRICAL DETAILS IV ELECTRICAL DETAILS V ONE-LINE DIAGRAM PANEL SCHEDULES I PANEL SCHEDULES II PANEL SCHEDULES III PANEL SCHEDULES IV PANEL SCHEDULES V PANEL SCHEDULES VI PANEL SCHEDULES VII PANEL SCHEDULES VIII US Army Corps of Engineers 1 Descr i pti on Dat e Appr . Mar k 2 3 4 5 SHEET NO. OF SEQUENCE NO. er o Acci den t s er o Tol er an ce Fil e Nam e: Pl ot Dat e: Pl ot Scal e: P R O J E C T NO . 1 2 3 4 5 A B C D A/ E FI RM 3 LI NES PROVI DED DESI GN BY: DRAWN BY: REVI EWED BY: S O L / C ON T R A C T NO . D C B A MONTH YEAR U. S. ARMY ENGI NEER DI STRI CT CORPS OF ENGI NEERS GULF REGI ON SOUTH, I RAQ Gulf Region District SMALL POLI CE STATI ON

Upload: hacong

Post on 14-Feb-2018

243 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

GENERAL NOTES ELECTRICAL INDEX

MDB

ELECTRICAL LEGEND

SYMBOL DESCRIPTION

SUB DISTRIBUTION BOARD

MDB (MAIN DISTRIBUTION BOARD)

ELECTRICAL OUTLET, 13AMP, 220V, 50HZ

STEEL FRAME PROTECTION

CEILING FAN REGULATOR

CEILING FAN

EXHAUST FAN

EMERGENCY EXIT SIGN & LIGHT, CADMIUM BATTERY

BACKUP WITH BATTRY BACKUP FOR 90min, 220V,50Hz

INDOOR LIGHT 220V, 50Hz, 36W, WATER PROOF

R

ELECTRICAL SWITCH, 10A, 220V, 50HZ, BY 2

ELECTRICAL SWITCH, 10A, 220V, 50HZ

EXIT

x x

E-001

NA

ME

2

EL

EC

TRIC

AL

LE

GE

ND,

GE

NE

RA

L

NO

TE

S,

AN

D IN

DE

X

ELECTRICAL SWITCH, 10A, 220V, 50HZ, THREE WAY

WATER, SPACE HEATER & AIR CONDITIONING ELECTRICAL POINT OF CONNECTION, 220V, 50 Hz

OUTDOOR LIGHT 220V,50Hz,400WWEATHER PROOF, 100m OUTWARD DISTANCE

120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS,72W, WITH COVER AND EMERGENCY BATTERY PACK

120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS,72W, WITH COVER

120cm FLUORESCENT LIGHT FIXTURE 220V, 2 LAMPS72 W, WEATHER PROOF COVER

(60X60) cm, ELECTRICAL MANHOLE, SEE SHEETE-503 FOR DETAIL

GROUND ROD, SEE SHEET E-502 FOR DETAIL

AIR TERMINAL FOR LIGHTNING PROTECTION SYSTEMSEE SHEET E-503 FOR DETAIL

DOWN CONDUCTOR FOR LIGHTNING PROTECTION SYSTEM, SEE SHEET E-504 FOR CONNECTION SCHEME

ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE 2005 NEC.

LIGHTING SWITCHES, CEILING FAN REGULATORS AND EXHAUST FAN SWITCHES

SHALL BE MOUNTED AT 1.2m ABOVE FINISHED FLOOR LEVEL AND 10cm FROM

DOOR OPENING.

ALL EXTERNAL ELECTRICAL SOCKETS SHALL BE MOUNTED AT 60cm ABOVE

FINISHED GRADE, HAVE GFCI PROTECTION AND A WEATHER PROOF COVER.

MINIMUM WIRE SIZE FOR POWER AND LIGHTING SHALL BE 4mm COPPER.

OUTLETS IN BATHROOMS SHALL BE MOUNTED AT 1.2m ABOVE FINISHED

FLOOR LEVEL. ALL OTHER OUTLETS SHALL BE MOUNTED AT 0.45m ABOVE

FINISHED FLOOR LEVEL.

OUTLETS SHALL BE PROTECTED BY GROUND FAULT CIRCUIT

INTERUPTER (GFCI) IN BATHROOMS AND WET AREAS.

SWITCHED OUTLETS FEEDING A/C UNITS SHALL BE MOUNTED IN

ACCORDANCE WITH THE INDOOR FAN/COIL UNITS REQUIREMENT.

DISTRIBUTION BOARDS SHALL BE MOUNTED AT 1.4m ABOVE FINISHED

FLOOR LEVEL.

THE MULTICORE CABLE USED SPECIFICATIONS ARE:

A. COPPER CONDUCTOR

B. PVC INSULATION

C. PVC FILTER

D. PVC OUTER SHEATH

E. MAXIMUM WORKING TEMPERATURE IS 75^C

THE SINGLE CORE CABLE USED SPECIFICATIONS ARE:

A. COPPER CONDUCTOR

B. PVC INSULATION

C. MAXIMUM WORKING TEMPERATURE IS 75^C

ALL PANEL BOARDS SHALL BE LISTED.

INSTALL EMERGENCY EXIT SIGNS IN ARABIC WITH INTERNATIONAL SYMBOLS

OVER PRIMARY EXIT FIRE ROUTES

ALL CONDUCTORS AND TRANSFORMER WINDINGS SHALL BE COPPER.

ALL CONDUIT SHALL BE EXPOSED METALLIC AND AND THE MINIMUM SIZE IS 16mm.

UNDERGROUND CABLE MUST BE ARMOURED IF NOT INSTALLED IN PVC CONDUIT.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

E-001

ES101

EG101

EG102

EG103

EL101

EL102

EL103

EL104

EL105

EP101

EP102

EP103

EP104

EP105

EP106

EP107

EP108

EP109

E-501

E-502

E-503

E-504

E-505

E-601

E-602

E-603

E-604

E-605

E-606

E-607

E-608

E-609

ELECTRICAL LEGEND, GENERAL NOTES, AND INDEX

EXAMPLE ELECTRICAL SITE PLAN

MAIN BUILDING GROUNDING PLAN

MAIN BUILDING LIGHTNING PROTECTION PLAN

RECEPTION BUILDING GROUNDING PLAN

GROUND FLOOR LIGHTING PLAN

FIRST FLOOR LIGHTING PLAN

ROOF FLOOR LIGHTING PLAN

RECEPTION BUILDING GROUND FLOOR LIGHTING PLAN

RECEPTION BUILDING ROOF FLOOR LIGHTING PLAN

GROUND FLOOR POWER PLAN

FIRST FLOOR POWER PLAN

ROOF FLOOR POWER PLAN

RECEPTION BUILDING POWER PLAN

GUARD TOWER LIGHTING AND POWER PLAN

GROUND FLOOR EQUIPMENT POWER PLAN

FIRST FLOOR EQUIPMENT POWER PLAN

ROOF FLOOR EQUIPMENT POWER PLAN

RECEPTION BUILDING EQUIPMENT POWER PLAN

ELECTRICAL DETAILS I

ELECTRICAL DETAILS II

ELECTRICAL DETAILS III

ELECTRICAL DETAILS IV

ELECTRICAL DETAILS V

ONE-LINE DIAGRAM

PANEL SCHEDULES I

PANEL SCHEDULES II

PANEL SCHEDULES III

PANEL SCHEDULES IV

PANEL SCHEDULES V

PANEL SCHEDULES VI

PANEL SCHEDULES VII

PANEL SCHEDULES VIII

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 2: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

MDB1-CKT06

MDB1-CKT08

SDB6-CKT09

MDB1-CKT06

MDB1-CKT06

TRENCH D1TRENCH D2

TRENCH D2

TRENCH D3

TRENCH D3

TRENCH D2

EXAMPLE ELECTRICAL SITE PLAN

NOT FOR CONSTRUCTION

X

X X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

ES101

EX

AM

PL

E

EL

EC

TRIC

AL

SIT

E

PL

AN

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

T-Wall

T-W

all

ECP

Reception

GateVehicle

PersonalGate REINFORCED CONCRETE PARKING AREA

REINFORCED CONCRETE PARKING AREA

Fuel

Point

Open Front Maintenance Bay

SepticWater

Generator

REIN

FO

RC

ED

CO

NC

RE

TE

AR

EA

T-

WA

LL

Roof Roof

ELECTRICAL TOWER & TRANSFORMER

15m X 6m

15m X 6m

34

m

X 6

m

T-WALL

Page 3: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

MDB

GENERAL NOTES

1

11

1

BARE COPPER WIRE 70mm

INSTALL 1m OUT FROM BUILDING

AND 1m BELOW FINISHED GRADE

16mm DIAMETER GROUND ROD

BARE COPPER WIRE 70mm

CONNECT TO GROUND RING

2

2

012 4 82 6X

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

MAIN BUILDING GROUNDING PLANSCALE: 20mm = 3m

X

EG101

MAIN

BUIL

DIN

G

GR

OU

NDIN

G

PL

AN

KEYED NOTES

GROUND ROD TRIANGLE SEE SHEET E-502 FOR DETAIL.1.

GROUNDING RING SHALL BE FUSION WELDED TO

BUILDING FOUNDATION STEEL.

A SEPARATE JUMPER SHALL BE INSTALLED

BETWEEN THE GROUNDING TERMINAL ON THE

DEVICE AND THE METALLIC BOX.

INSTALL A GROUNDING CONDUCTOR IN EVERY

RACEWAY.

PROVIDE A SEPARATE GROUND WIRE FOR LIGHT

FIXTURES.

EACH RECEPTACLE BRANCH CIRCUIT SHALL HAVE

AN INDIVIDUAL GROUNDING CONDUCTOR INSTALLED

FOR EACH DEVICE.

CONTRACTOR SHALL VERIFY THAT EARTHING

RESISTANCE IS LESS THAN 25 OHMS.

SEE SHEET E-503 AND E-504 FOR GROUNDING DETAILS.

1.

2.

3.

4.

5.

6.

7.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

EW

H

ARMORYOFFICE-1OFFICE-2OFFICE-3OFFICE-4OFFICE-5

BREAKROOM

CORRIDOR-2

CO

RRID

OR-1

STORAGE-1 KITCHEN

BATHROOM-1

MALE JAIL-2

CORRIDOR-4

FEMALE JAILMALE JAIL-1

INTERVIEW

ROOM-2

INTERVIEW

ROOM-1

CO

RRID

OR-3

UTILIT

Y

RO

OM

ELECTRICAL

ROOM-1

OPEN SPACE

LOBBY

Page 4: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

012 4 82 6

SCALE: 20mm = 3m

MAIN BUILDING LIGHTNING PROTECTION PLANX

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EG102

X

MAIN

BUIL

DIN

G

LIG

HT

NIN

G

PR

OT

EC

TIO

N

PL

AN

5.82m

9.55m

5.30m

3.60m

6.90m

0.60m

0.60m

GENERAL NOTES

1.

2.

3.

4.

5.

DOWN CONDUCTOR

(TYPICAL)

FOR AIR TERMINAL DETAIL SEE SHEET E-503.

FOR DOWN CONDUCTOR CONNECTION SCHEME SEE

SHEET E-504.

MAIN CONDUCTOR CABLE SHALL HAVE A MINIMUM

CROSS SECTION AREA OF 29mm AND MINIMUM

WEIGHT OF .278kg/m.

LIGHTNING PROTECTION SYSTEM SHALL BE

INSTALLED PER NFPA 780.

LIGHTNING PROTECTION SYSTEM SHALL BE CONNECTED

TO THE GROUND RING BY DOWN CONDUCTORS AS

SHOWN ON E-504.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

STORAGE-3

STORAGE-2

CORRIDOR-9

Page 5: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

GENERAL NOTES

2

2

SDB6

1

1

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

RECEPTION BUILDING GROUNDING PLAN SCALE: 20mm = 1m

EG103

012 42

BARE COPPER WIRE 70mm

INSTALL 1m OUT FROM

BUILDING AND 1m BELOW

FINISHED GRADE

BARE COPPER WIRE 10mm

CONNECT TO GROUND RING

16mm DIAMETER GROUND ROD

KEYED NOTES

GROUND ROD TRIANGLE SEE SHEET E-502 FOR DETAILS.1.

RE

CE

PTIO

N

BUIL

DIN

G

GR

OU

NDIN

G

PL

AN

GROUNDING RING SHALL BE FUSION WELDED TO

BUILDING FOUNDATION STEEL.

A SEPARATE JUMPER SHALL BE INSTALLED

BETWEEN THE GROUNDING TERMINAL ON THE

DEVICE AND THE METALLIC BOX.

INSTALL A GROUNDING CONDUCTOR IN EVERY

RACEWAY.

PROVIDE A SEPARATE GROUND WIRE FOR LIGHT

FIXTURES.

EACH RECEPTACLE BRANCH CIRCUIT SHALL HAVE

AN INDIVIDUAL GROUNDING CONDUCTOR INSTALLED

FOR EACH DEVICE.

CONTRACTOR SHALL VERIFY THAT EARTHING

RESISTANCE IS LESS THAN 25 OHMS.

SEE SHEET E-503 AND E-504 FOR GROUNDING DETAILS.

1.

2.

3.

4.

5.

6.

7.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

OFFICE-1

OFFICE-2

BATHROOM

Page 6: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

OFFICE-1

ARMORY

CO

RRID

OR-1

CORRIDOR-2

OFFICE-2OFFICE-3OFFICE-4OFFICE-5

CO

RRID

OR-3

CORRIDOR-4

OPEN SPACE

BATHROOM-1

BREAKROOM

KITCHEN

STORAGE-1

UTILIT

Y

RO

OM

SDB2-08

SDB2-15

SDB1-30SDB1-30

SDB2-03

SDB2-08

SDB2-08

SDB2-12

SDB2-02

SDB2-39

SDB2-06

SDB1-06

SDB2-02

SDB1-01SDB1-02SDB1-35SDB1-04

SDB1-05SDB1-08

SDB1-32

SDB1-32

SDB1-08

SDB1-08

SDB1-31

SDB2-39

SDB2-39

SDB2-15

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EL101

012 4 82 6X

SCALE: 20mm = 3m

GROUND FLOOR LIGHTING PLAN

GR

OU

ND

FL

OO

R

LIG

HTIN

G

PL

AN

MALE JAIL-1 MALE JAIL-2

FEMALE JAIL

INTERVIEW

ROOM-2

INTERVIEW

ROOM-1

ELECTRICAL

ROOM-1WALL MOUNT LIGHT AT

2.5m ABOVE FINISHED

FLOOR OF LANDING

EXIT

EXIT

EXIT

SDB1-05

PHOTOCELL

SYSTEM

SDB2-5

SDB2-7

KEYED NOTES

LIGHTS INSTALLED IN MALE JAIL-1, MALE JAIL-2, AND

FEMALE JAIL MUST HAVE STEEL FRAME PROTECTION.

PHOTOCELL SYSTEM FOR ROOF MOUNTED EXTERIOR

LIGHTS. MOUNT PHOTOCELL ON NORTH FACE OF

BUILDING AT 1.2m ABOVE FINISHED GRADE. SEE SHEET

E-504 FOR DETAIL.

1.

2.

1

1

1

2

GENERAL NOTES

MOUNT ALL EXTERNAL LIGHTS INSIDE THE

OPEN SPACE AT 3.5m ABOVE FINISHED GRADE.

MOUNT OTHER EXTERNAL LIGHTS AT 15cm

ABOVE DOOR.

1.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

EW

H

UP

Page 7: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB3-22

SDB3-36

SDB3-33

SDB3-33

SDB3-19

SDB3-06

SDB3-06

SDB3-06

SDB3-06

SDB4-05

SDB4-06 SDB4-06

SDB3-01

SDB3-01

SDB3-25

SDB4-03SDB4-10

SDB4-18

SDB3-02

SDB3-33SDB3-33

SDB1-32

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EL102

012 4 82 6X

SCALE: 20mm = 3m

FIRST FLOOR LIGHTING PLAN

FIR

ST

FL

OO

R

LIG

HTIN

G

PL

AN

SDB4-4

SDB4-4

DORMITORY-2

DORMITORY-3

BATHROOM-2

EWH

OFFICE-9

OFFICE-7

OFFICE-8

CORRIDOR-6

CORRIDOR-8

CO

RRID

OR-7

CO

RRID

OR-5ELECTRIC

ROOM-2

OFFICE-10

WALL MOUNT LIGHT AT3.5m ABOVE FINSHEDFLOOR OF LANDING

EXIT

EXIT

EXIT

DORMITORY-4

DORMITORY-1

BATHROOM-3

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 8: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB5-2 SDB5-4

SDB5-01

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EL103

012 4 82 6X

SCALE: 20mm = 3m

ROOF FLOOR LIGHTING PLAN

RO

OF

FL

OO

R

LIG

HTIN

G

PL

AN

STORAGE-2

CORRIDOR-9

STORAGE-3

CONTROLLED BY

PHOTOCELL

SDB2-7

CONTROLLED BY

PHOTOCELL

SDB2-5

EXIT

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 9: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB6-01

SDB6-01

SDB6-01

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

SCALE: 20mm = 1m

EL104RECEPTION BUILDING GROUND FLOOR LIGHTING PLAN

RE

CE

PTIO

N

BUIL

DIN

G

GR

OU

ND

FL

OO

R

LIG

HTIN

G

PL

AN

OFFICE-1

OFFICE-2

BATHROOM

012 42

EXIT

EXIT

KEYED NOTES

PHOTOCELL SYSTEM FOR ROOF MOUNTED EXTERIOR LIGHTS.

MOUNT PHOTOCELL ON NORTH FACE OF BUILDING AT 1.2m

ABOVE FINISHED GRADE. SEE SHEET E-504 FOR DETAIL.

1.

1

PHOTO CELL

SYSTEM

SDB6-4

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 10: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

RECEPTION BUILDING ROOF FLOOR LIGHTING PLANSCALE: 20mm = 1m

RE

CE

PTIO

N

BUIL

DIN

G

RO

OF

FL

OO

R

LIG

HTIN

G

PL

AN

EL105

012 42

FROM PHOTOCELL

SDB6-4

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 11: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB2-38

SDB2-37

SDB2-24

SDB2-25

SDB2-22

SDB2-29

SDB2-35

SDB2-18

SDB2-17

SDB2-34

SDB2-33

SDB2-32

SDB2-14

SDB2-13

SDB2-26

SDB1-29

SDB1-36

SDB1-21

SDB1-28

SDB1-27

SDB1-26

SDB1-19

SDB1-25

SDB1-16 SDB1-14

SDB1-24

SDB1-12

SDB1-23

SDB1-10

SDB1-09

SDB1-22

SDB2MDB

SDB1

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP101

012 4 82 6X

SCALE: 20mm = 3m

GROUND FLOOR POWER PLAN

GR

OU

ND

FL

OO

R

PO

WE

R

PL

AN

OFFICE-1 ARMORY

CO

RRID

OR-1

CORRIDOR-2

OFFICE-2OFFICE-3

OFFICE-4

OFFICE-5

CO

RRID

OR-3

CORRIDOR-4

OPEN SPACE

BATHROOM-1

BREAKROOM

KITCHEN

STORAGE-1

MALE JAIL-1 MALE JAIL-2

FEMALE JAIL

ELECTRICAL

ROOM-1

INTERVIEW

ROOM 2

INTERVIEW

ROOM 1

GENERAL NOTES

1.

SDB2-36SDB2-31

UTILIT

YR

OO

M

SDB2-9,10,11

SDB2-30

SDB2-27FOR WATER PUMP

GFCI

GFCI

GFCI

GFCI

ALL EXTERIOR RECEPTACLES MUST HAVE

WEATHER PROOF WHILE IN USE COVER

AND GFCI PROTECTION.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

UP

Page 12: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB3-30

SDB3-29

SDB3-16

SDB3-26SDB3-28

SDB3-27

SDB3-13

SDB3-14

SDB3-20

SDB3-04

SDB3-23

SDB3-24

SDB3-05

SDB4-09

SDB4-29

SDB4-31

SDB4-12

SDB4-15

SDB4-34SDB4-28

SDB4-32SDB4-26

SDB4-01

SDB4-22

SDB4-33SDB4-27SDB4-36

SDB4-35

SDB4-21

SDB4-16

SDB3-31 SDB4SDB3

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP102

012 4 82 6X

SCALE: 20mm = 3m

FIRST FLOOR POWER PLAN

FIR

ST

FL

OO

R

PO

WE

R

PL

AN

DORMITORY-2

DORMITORY-1

DORMITORY-3

DORMITORY-4

BATHROOM-2

EWH

OFFICE-9

OFFICE-7

OFFICE-8

CORRIDOR-6

CORRIDOR-8

CO

RRID

OR-7

CO

RRID

OR-5

ELECTRICROOM-2

OFFICE-10

BATHROOM-3

GFCI

GFCI

GFCI GFCI

GFCI

GFCI

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 13: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB5-07

SDB5-08

SDB5-06

SDB5-09

SDB5

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP103

012 4 82 6X

SCALE: 20mm = 3m

ROOF FLOOR POWER PLAN

RO

OF

FL

OO

R

PO

WE

R

PL

AN

STORAGE-2

CORRIDOR-9

STORAGE-3

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

DN

Page 14: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB6-12

SDB6-06

SDB6-08

SDB6-05

SDB6

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

RECEPTION BUILDING POWER PLANSCALE: 20mm = 1m

RE

CE

PTIO

N

BUIL

DIN

G

PO

WE

R

PL

AN

EP104

OFFICE-1

BATHROOM

OFFICE-2

012 42

SDB6-10

SDB6-7

SDB6-3 FOR WATER PUMP

GFCIWP

GFCI

GFCI

GFCI

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 15: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

GUARD TOWER 1: SDB7-3GUARD TOWER 2: SDB8-3GUARD TOWER 3: SDB9-3GUARD TOWER 4: SDB10-3

GUARD TOWER 1: SDB7-1GUARD TOWER 2: SDB8-1GUARD TOWER 3: SDB9-1GUARD TOWER 4: SDB10-1

GUARD TOWER 1: SDB7GUARD TOWER 2: SDB8GUARD TOWER 3: SDB9GUARD TOWER 4: SDB10

GUARD TOWER 1: SDB7-2GUARD TOWER 2: SDB8-2GUARD TOWER 3: SDB9-2GUARD TOWER 4: SDB10-2

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

GUARD TOWER POWER PLANSCALE: 20mm = 1m

SCALE: 20mm = 1m

GUARD TOWER LIGHTING PLAN

EP105

GU

AR

D

TO

WE

R

PO

WE

R

AN

D

LIG

HTIN

G

PL

AN

012 42

LIGHT SHALL HAVEWEATHER PROOF COVER

GENERAL NOTES

ALL OUTLETS INSTALLED GUARD

TOWERS SHALL HAVE GFCI

PROTECTION AND A WEATHER

PROOF ENCLOSURE.

POWER PANELS SHALL BE RATED

NEMA 3R.

1.

2.

250 WATT(TYPICALFOR GUARDTOWER ONLY)

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 16: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

R

R

R R R R

R

R

R

R

R

R

R

R

R

SDB1-05SDB1-04 SDB1-35

SDB1-02 SDB1-01

SDB1-06

SDB1-06

SDB1-06

SDB1-05

SDB2-06

SDB2-06

SDB2-36

SDB2-36

SDB2-12

SDB2-03

SDB2-15

SDB2-15

SDB1-30

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP106

012 4 82 6X

SCALE: 20mm = 3m

OFFICE-1

ARMORY

CO

RRID

OR-1

CORRIDOR-2

OFFICE-2OFFICE-3OFFICE-4OFFICE-5

CO

RRID

OR-3

CORRIDOR-4

OPEN SPACE

BATHROOM-1

BREAKROOM

KITCHEN

STORAGE-1

UTILIT

Y

RO

OM

MALE JAIL-1 MALE JAIL-2

FEMALE JAIL

INTERVIEW

ROOM-2

INTERVIEW

ROOM-1

ELECTRICAL

ROOM-1

SDB2-1

SDB1-05

GROUND FLOOR EQUIPMENT POWER PLAN

GR

OU

ND

FL

OO

R

EQ

UIP

ME

NT

PO

WE

R

PL

AN

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

UP

Page 17: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

R

R

SDB3-22

SDB3-36

SDB3-36

SDB3-22

SDB3-19

SDB3-19

SDB3-25

SDB3-25

SDB3-01

SDB3-01

SDB4-06

SDB4-06

SDB4-05

SDB3-06

SDB4-03

SDB4-03SDB4-10

SDB4-10

SDB4-18

SDB4-18

SDB3-02

R R R R

R

R

R

R

R RR R

R

R

R

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP107

012 4 82 6X

SCALE: 20mm = 3m

DORMITORY-2

DORMITORY-1

DORMITORY-3DORMITORY-4

BATHROOM-2

EWH

OFFICE-9

OFFICE-7

OFFICE-8

CORRIDOR-6

CORRIDOR-8

CO

RRID

OR-7

CO

RRID

OR-5

ELECTRICROOM-2

OFFICE-10

FIR

ST

FL

OO

R

EQ

UIP

ME

NT

PO

WE

R

PL

AN

FIRST FLOOR EQUIPMENT POWER PLAN

BATHROOM-3

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 18: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB5-04

SDB5-01

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

EP108

012 4 82 6X

SCALE: 20mm = 3m

STORAGE-2

CORRIDOR-9

STORAGE-3

RO

OF

FL

OO

R

EQ

UIP

ME

NT

PO

WE

R

PL

AN

ROOF FLOOR EQUIPMENT POWER PLAN

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

DN

Page 19: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

SDB6-02

SDB6-02

SDB6-02

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

X

SCALE: 20mm = 1m

EP109

OFFICE-1

BATHROOM

OFFICE-2

R

R

RE

CE

PTIO

N

BUIL

DIN

G

EQ

UIP

ME

NT

PO

WE

R

PL

AN

RECEPTION BUILDING EQUIPMENT POWER PLAN

012 42

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 20: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

PVC PIPE

WARNING RED/YELLOWNYLON TAPE 25 cm WIDTH

BACKFILL (90%COMPACTION)

BRICK(8X12X24 cm)

20cm

80cm

30cm

15cm

20cm

80cm

NOT TO SCALE

CABLE TRENCH D1

PVC PIPE

WARNING RED/YELLOWNYLON TAPE 25 cm WIDTH

BACKFILL (90%COMPACTION)

BRICK(8X12X24 cm)

80cm

30cm

15cm

NOT TO SCALE

CABLE TRENCH D2

20cm

80cm

PVC PIPE

WARNING RED/YELLOW

NYLON TAPE 25 cm WIDTH

BACKFILL (90%COMPACTION)

BRICK(8X12X24 cm)

30cm

15cm

NOT TO SCALE

CABLE TRENCH D3

20cm

80cm

80cm

PVC PIPE

WARNING RED/YELLOWNYLON TAPE 25 cm WIDTH

BACKFILL (90%COMPACTION)

BRICK(8X12X24 cm)

30cm

NOT TO SCALE

CABLE TRENCH D4

80cm

80cm

15cm

SMOOTH SANDSMOOTH SAND

SMOOTH SANDSMOOTH SAND

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-501

X

GENERAL NOTES

CONTRACTOR SHALL USE THESE BASIC

TRENCH LAYOUTS WHEN CREATING THE

ELECTRICAL SITE PLAN.

1.

EL

EC

TRIC

AL

DE

TAIL

S I

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 21: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

2.5m

STEEL CAST CONCRETEINSPECTION PIT WITH COVER

16mm DIAMETERCOPPER GROUND ROD

2

1.83m

NOT TO SCALE

GROUND ROD TRIANGLE DETAIL

NOT TO SCALE

GROUND ROD DETAIL

EARTH TEST BOX

15cm

3cm

3cm

25cm

30cm

31cm

15cm

3cm

GROUND LEVEL

CAST IRON COVER WITH RECESSEDLIFTING HOOK AND ENGRAVEDINSCRIPTION "ELECTRIC EARTH PIT"

CONCRETE WALL

PROTECTIVE CAP FILLED WITHNEUTRAL VASELINE U-BOLTED BRASS CONNECTOR

(SEE DETAIL A)

VIRGIN SOIL

3x25mm COPPER TAPE

50 mm DIAMETER SLEVE

GRAVEL FILLING

COPPER GROUND ROD

GRAVEL FILLING AT DRAIN POINT

NOT TO SCALE

DETAIL A

NOT TO SCALE

EARTH PIT CONSTRUCTION

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-502

X

EL

EC

TRIC

AL

DE

TAIL

S II

1.83m

BARE COPPER CABLE 70 mm

25mm DIAMETER DRAIN(IN AREAS WITH LOWWATER LEVELS THISCAN BE DELETED)

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 22: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

GENERAL NOTES

1.

2.

GROUND BUSNEUTRAL BUS

WATER SERVICE

GROUND RODS

BUILDING STEEL

THE SIZE OF THE CONDUCTOR IS THE SAME SIZEAS THE GROUNDING CONDUCTOR INDICATED ONTHE PANEL SCHEDULE

THE SIZE OF THE CONDUCTOR IS THE SAME SIZEAS THE GROUNDING CONDUCTOR INDICATED ONTHE PANEL SCHEDULE

NOT TO SCALE

SERVICE GROUNDING DETAIL

NOT TO SCALE

AIR TERMINAL DETAIL

COPPERROD

MULTIPLE POINTAIR TERMINAL

CONCRETEBASE

CAST IRON COVER

CONCRETE (1:2:4)

CONCRETE BRICK

WALL

CRUSHED STONE

CEMENT

PLASTERING

1:3

10 cm

15 cm

110 cm

10 cm

60 cm

FRAME ANGLE IRON(5*5) cm

NOT TO SCALE

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-503

X

EL

EC

TRIC

AL

DE

TAIL

S III

MAKE CONNECTION ONLY AT MDB1(THE SIZE OF THE CONDUCTORIS THE SAME SIZE AS THE GROUNDING CONDUCTOR INDICATEDON THE PANEL SCHEDULE)

CONCRETE WITH

THE GROUNDING SYSTEM SHALL COMPLY WITH

NATIONAL ELECTRICAL CODE (NEC) ARTICLE 250.

GROUND ROD ELECTRODES SHALL NOT BE LESS THAN

2.5m IN LENGTH AND 16mm IN DIAMETER IN

ACCORDANCE WITH NEC ARTICLE 250.52.

HANDHOLE DETAIL

FUSION (EXOTHERMAL) WELDING

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 23: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

GENERAL NOTES

50mm

>100mm

60mm

200mm

50mm

250mm

70mm COPPER CABLE

BRASS PLATE

BRASS CONNECTOR

COPPER GROUND ROD16mm DIAMETER

PROTECTIVE PIPEHOLDING CLAMP

CONNECTIONCLAMP

PVC PIPE

GALVANIZED STEELSUPPORT

WALL

DOWN CONDUCTOR

GALVANIZEDPROTECTIVEPIPE

NOT TO SCALE

CONNECTION SCHEMEOF DOWN CONDUCTOR

2

NOT TO SCALE

BONDING BAR DETAIL

CONNECT TO

PERIMETER

GROUND

BOLT TO WALL

BOLT TO WALLCONNECTIONS FOR

MISC. METAL

EQUIPMENT AND

ENCLOSURES

11mm

11mm

13mm

30mm

11mm

NOT TO SCALE

BONDING BAR CABLECONNECTION DETAIL

BONDING BAR

CABLE LUG

COPPER BOLT

COPPERWASHER

5mm

PHOTO CELL

25A, 3 PHASECONTACTOR

NEUTRALEARTH

TO LIGHTING

NOT TO SCALE

PHOTO CELL SYSTEM DETAIL

CIRCUIT ASSHOWN ONPLANS

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-504

X

EL

EC

TRIC

AL

DE

TAIL

S IV

3-6mm 2

ALL INTERNAL METAL EQUIPMENT AND ENCLOSURES SHALL

BE CONNECTED TO THE SERVICE EQUIPMENT GROUNDING

SYSTEM OR THE BONDING BAR BY USING MINIMUM 10mm

STRANDED BARE COPPER CONDUCTORS WITH CRIMPED CABLE

SHOES ON BOTH ENDS. CABLE SHOE BUS-BAR CONNECTIONS

SHALL BE MADE BY BOLT-NUTS.

ALL WATER, FUEL, AND OTHER METALLIC PIPES SHALL BE

BONDED TO EQUIPMENT GROUNDING SYSTEM.

BONDING BAR SHALL BE MADE OF SOLID COPPER (50mm

x 5mm).

1.

2.

3.

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 24: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

NOT TO SCALE

POWER GENERATION PAD DETAIL

KEYED NOTES

1.

LIGHTNING PROTECTION

SEE DETAIL L1

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-505

X

MDB1600A

1

70mm COPPER SINGLE

CORE WIRE

CONNECTION BY WELDING COPPER ROD

MULTIPLE POINT AIR TERMINAL

SURGE PROTECTION SHALL BE PROVIDED BETWEEN THE

AERIAL SURGE ARRESTORS AND GENERATOR OR ON A

BUS FOR SEVERAL GENERATORS. WHERE A GENERATOR

IS CONNECTED TO AN OVERHEAD LINE THROUGH A

TRANSFORMER, PROVIDE A STATION TYPE SURGE ARRESTOR

ON THE HIGH VOLTAGE SIDE OF THE TRANSFORMER.

NOT TO SCALE

DETAIL L1

1.7m 1.8m

4.3m

4.2m

2.5m

11m

250mm

2

300 kVAGENERATOR

300 kVATRANSFORMER

600A4 POLEMTS

IF LOCAL POWER IS AVAILABLE INSTALL 300 kVA TRANSFORMER.

IF LOCAL POWER IS NOT AVAILABLE INSTALL 300 kVA GENERATOR.

EL

EC

TRIC

AL

DE

TAIL

S

V

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 25: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

G

600A

500A 63A 25A

20A

SD

B1

300 kVA

TRANSFORMER600A

1-50mm GND2

2 SETS OF 4-185mm2

2 SETS OF 4-185mm

600A

1-50mm GND

1-50mm GND

2 SETS OF 4-185mm

600A 1-50mm GND2

2 SETS OF 4-185mm2

1-50mm GND22

300 kVA

GENERATOR2

2

2

1-50

mm

GN

D

2

SE

TS

OF 4-185

mm

2

2

1-35

mm

GN

D

2

SE

TS

OF 4-15

0m

m2

2

25A

SP

AR

E

4-25

mm 2

1-6

mm

GN

D

25A

2

1-6

mm

GN

D

25A

2

1-6

mm

GN

D

25A 25A 25A 25A

4-16

mm

2

2

1-6

mm

GN

D

25A

SP

AR

E

25A

SP

AR

E

4-5

0m

m2

2

1-16

mm

GN

D

4-7

0m

m2

2

1-16

mm

GN

D

SD

B2

4-50

mm

2

2

1-16

mm

GN

D

SD

B3

4-7

0m

m2

2

1-16

mm

GN

D

SD

B4

125A

4-6

mm

2

2

1-4

mm

GN

D

SD

B5

63A

SP

AR

E

MDB

LOCATED IN MAIN BUILDING

MDB1

LOCATED NEXT TO

GENERATOR

SD

P6

1-10

mm

GN

D2

2

SD

P8

SD

P9

SD

B7

SD

B10

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-601

X

ON

E-

LIN

E

DIA

GR

AM

SP

AC

E

FO

R

PE

RIM

ET

ER

LT

G

SP

AC

E

FO

R

GE

NE

RA

TO

R

PA

D

LT

G

SP

AC

E

FO

R

PE

RIM

ET

ER

LT

G

1

KEYED NOTES

1.

4-16

mm

2

4-16

mm

2

4-16

mm

2

DISCONNECT

SWITCH

DISCONNECT

SWITCH

500A

4-POLE

MTS

IF LOCAL POWER IS AVAILABLE INSTALL 300 kVA TRANSFORMER.

IF LOCAL POWER IS NOT AVAILABLE INSTALL 300 kVA GENERATOR.

125A 150A 130A

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 26: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-602

X

PA

NE

L

SC

HE

DU

LE

S I

FED FROM: MTS

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 3R ENCLOSURE, 600A BUS

2 2

100% NEUTRAL

CONTINUOUS (A): 600

AIC RATING (A): 42000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 7

24-251-10 GND

3 25

8

-- 9

LOAD(VA)

CABLE SIZE: 2 SETS OF 4-185mm, 1-50mm GND

MDB

SDB6

SDB74-161-6 GND

500 278698

20606

3580 -- --

TOTAL CONNECTED LOAD (VA): 302,844 TOTAL DEMAND LOAD (VA): 352,062

TOTAL DEMAND (AMPS): 534.9

LOAD(VA)

4 104-161-6 GND

54-161-6 GND

6 25

11

-- 12

SDB8

SDB9

SPACE4-161-6 GND

3580 -- --

PANEL SCHEDULE MDB1, MCB = 600A

NUMER OF CIRCUITS: 12

SDB10

SPACE FOR PERIMETER LTG

SPACE FOR GENERATOR PAD LTG

SPACE FOR PERIMETER LTG

-- -- --

------

--

--

--

--

--

--

SPACE

SPACE

63

3580

3580

LOCATION: NEXT TO GENERATOR PAD

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 1 ENCLOSURE, 500A BUS

2 2

100% NEUTRAL

CONTINUOUS (A): 500

AIC RATING (A): 42000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 4

24-701-16 GND

3 20

5

-- 6

LOAD(VA)

CABLE SIZE: 2 SETS OF 4-150mm, 1-35mm GND

SDB1

SDB2

SDB54-61-4 GND

125 56844

83508

5330 -- --

TOTAL CONNECTED LOAD (VA): 278,698 TOTAL DEMAND LOAD (VA): 317,136

TOTAL DEMAND (AMPS): 481.8

LOAD(VA)

PANEL SCHEDULE MDB, MCB = 500A

NUMER OF CIRCUITS: 6

LOCATION: ELECTRICAL ROOM GROUND FLOOR

SDB3

SDB4

SPACE

4-501-16 GND

60570 1254-501-16 GND

72446 1304-701-16 GND

150

25

25

2(4-1501-35 GND)

SURFACE MOUNTED

SURFACE MOUNTED

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 27: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-603

X

PA

NE

L

SC

HE

DU

LE

S II

FED FROM: MDB

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 36

CABLE SIZE: 4-50mm, 1-16mm GND

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 1 ENCLOSURE, 125A BUS

LOCATION: ELECTRICAL ROOM GROUND FLOOR2 2

100% NEUTRAL

CONTINUOUS (A): 125

AIC RATING (A): 22000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 448 2758

448

1650

19

2098

5756

5748

5000

5540

5400

6980

5000

2758

540

2760

1980

448

1980

2-41-4 GND

10

22-41-4 GND

10 448

3 10

42-41-4 GND

10 448

52-41-4 GND

10 756

62-41-4 GND

10 748

7 10

82-41-4 GND

10 540

92-41-4 GND

16 1650

102-41-4 GND

16 1980

11 10

122-41-4 GND

16 2640

SPARE

SPARE

ARMORY OUTLETS

ARMORY OUTLETS

SPARE

--

--

--

--

--

--

13 10

142-41-4 GND

16 2310

15 16

162-41-4 GND

16 1980

17 10

18 10

162-41-4 GND

10 20

1650 162-41-4 GND

21

1650 162-41-4 GND

22

5000 32 23

5000 322-101-6 GND

24

5000 322-101-6 GND

25

5000 322-101-6 GND

26

3750 252-101-6 GND

27

5000 322-101-6 GND

28

5000 322-101-6 GND

29

448 102-41-4 GND

30

540 102-41-4 GND

31

450 102-41-4 GND

32

10 33

10 34

448 102-41-4 GND

35

1980 162-41-4 GND

36

SPARE----

OFFICE-1 AIR CONDITIONING

OFFICE-2 AIR CONDITIONING

OFFICE-3 AIR CONDITIONING

OFFICE-4 AIR CONDITIONING

OFFICE-5 AIR CONDITIONING

OFFICE-5 AIR CONDITIONING

ENTRANCE AIR CONDITIONING

ENTRANCE LTG & CEILING FAN

SPARE

SPARE

OFFICE-3 LTG & CEILING FAN

--

--

--

--

2-101-6 GND

LOAD(VA)

ARMORY LTG & EXHAUST/CEILING FAN

CORRIDOR-2/ELEC RM. LTG

19356 19952 17536TOTAL CONNECTEDLOAD (VA)

PANEL SCHEDULE SDB1, MCB = 125A

TOTAL CONNECTED LOAD (VA): 56,844 TOTAL DEMAND LOAD (VA): 65,282 TOTAL DEMAND (AMPS): 99.2

OFFICE-5 LTG & CEILING/EXHAUST FANS

LOAD(VA)

2310 CORRIDOR-1/EXTERIOR OUTLETS

OPEN SPACE LTG

SURFACE MOUNTED

OFFICE-1 LTG & CEILING FANS

OFFICE-2 LTG & CEILING FANS

OFFICE-4 LTG & CEILING FANS

SPARE -- --

SPARE -- --

OFFICE-3 OUTLETS

--

----

--

SPARE

SPARE

OFFICE-5 OUTLETS

OFFICE-1/EXTERIOR OUTLETS

OFFICE-2/CORRIDOR-2 OUTLETS

ELECTRICAL ROOM/CORRIDOR/EXTERIOROUTLETS

OFFICE-5/EXTERIOR/LOBBY OUTLETS

0

CORRIDOR-3/STAIRS LTG + EXIT SIGN

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 28: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-604

X

FED FROM: MDB

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 42

CABLE SIZE: 4-70mm, 1-16mm GND

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 1 ENCLOSURE, 150A BUS

LOCATION: ELECTRICAL ROOM GROUND FLOOR2 2

100% NEUTRAL

CONTINUOUS (A): 150

AIC RATING (A): 22000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 880 3190

540

2940

2310 22

3480

3650

2036

5540

7000

7750

9000

5930

6650

5730

5716

3750

6060

2546

2-41-4 GND

10

22-41-4 GND

10 540

3 10

4 16

5 16

62-41-4 GND

10 716

7 16

82-41-4 GND

10 540

9

10 25

11

122-41-4 GND

10 930

132-41-4 GND

16 1650

142-41-4 GND

16 1980

152-41-4 GND

10 716

16 16

172-41-4 GND

16 2310

182-41-4 GND

16 1650

162-41-4 GND

10 23

1650 162-41-4 GND

24

1980 162-41-4 GND

25

1650 16 26

16 27

10 28

5000 322-101-6 GND

29

3000 202-61-6 GND

30

3750 252-101-6 GND

31

5000 322-101-6 GND

32

5000 322-101-6 GND

33

5000 322-101-6 GND

34

3750 252-101-6 GND

35

32 36

25 37

3750 252-101-6 GND

38

896 102-41-4 GND

39

BREAKROOM AIR CONDITIONING

BREAKROOM AIR CONDITIONING

LOAD(VA)

26820 30520 26168TOTAL CONNECTEDLOAD (VA)

PANEL SCHEDULE SDB2, MCB = 150A

KITCHEN EXHAUST HOOD

PA

NE

L

SC

HE

DU

LE

S III

2-41-4 GND

1290

BREAKROOM LTG & CEILING FANS

EXTERIOR LTS2-61-4 GND

2000

MALE-1/MALE-2/FEMALE JAIL LTG &EXHAUST FANS

KITCHEN/EXTERIOR OUTLETS

INTERVIEW ROOM-2 OUTLETS

2-41-4 GND

SPARE----

MALE JAIL-2 AIR CONDITIONING

WATER HEATER

FEMALE JAIL AIR CONDITIONING

KITCHEN AIR CONDITIONING

MALE JAIL-1 AIR CONDITIONING2-102-6 GND

5000

2-101-6 GND

3750 INTERVIEW ROOM-2 AIR CONDITIONING

INTERVIEW ROOM-1 AIR CONDITIONING

KITCHEN/STORAGE-1 LTG &CEILING FANS

TOTAL CONNECTED LOAD (VA): 83,508 TOTAL DEMAND LOAD (VA): 92,571 TOTAL DEMAND (AMPS): 140.6

LOAD(VA)

ELECTRIC STOVE4-61-6 GND

4000

4000

4000

19 16

20 16

21 16

10 40

10 41

10 42

--

--

--

--

--

--

--

--

--

--

--

--

SPARE

SPARE

SPARE

SPARE

SPARE

SPARE --

--

--

CORRIDOR-4/UTILITY ROOM LTG

FIRE ALARM CONTROL PANEL2-41-4 GND

1500

EXTERIOR LTS2-61-4 GND

2000

BATHROOM-1 LTG & EXHAUST FANS

INTERVIEW ROOM-1/INTERVIEW ROOM-2 LTG & CEILING FANS

----SPARE

CORRIDOR-1/EXTERIOR/BATHROOM-2 OUTLETS

-- -- SPARE

INTERVIEW ROOM-1/INTERVIEWROOM-2/ OUTLETS

SPACE HEATER BATHROOM-2

2000

SURFACE MOUNTED

STORAGE-1 OUTLETS

BREAKROOM OUTLETS

BREAKROOM OUTLETS

UTILITY ROOM/CORRIDOR-4 OUTLETS

WATER PUMP2-41-4 GND

1320

CORRIDOR-1 LTG + EXIT SIGNS

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 29: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-605

X

PA

NE

L

SC

HE

DU

LE

S IV

FED FROM: MDB

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 36

CABLE SIZE: 4-50mm, 1-16mm GND

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 1 ENCLOSURE, 125A BUS

LOCATION: ELECTRICAL ROOM FIRST FLOOR

SURFCE MOUNTED

2 2

100% NEUTRAL

CONTINUOUS (A): 125

AIC RATING (A): 22000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 758 1654

3088

896 19

3026

7310

6470

716

6250

6250

5000

3750

3750

7640

1320

810

2640

896

2-41-4 GND

10

22-41-4 GND

10 448

3 10

42-41-4 GND

16 2310

52-41-4 GND

16 2310

62-41-4 GND

10 1470

7 10

8 10

9 16

10 16

11 10

12 16

SPARE

SPARE

--

--

--

--

132-41-4 GND

16 2640

142-41-4 GND

16 1320

15 16

162-41-4 GND

16 2640

17 10

18 16

102-41-4 GND

16 20

10 21

716 102-41-4 GND

22

5000 32 23

5000 322-101-6 GND

24

716 102-41-4 GND

25

6250 402-101-6 GND

26

6250 402-101-6 GND

27

5000 322-101-6 GND

28

3750 252-101-6 GND

29

3750 252-101-6 GND

30

5000 322-101-6 GND

31

10 32

10 33

16 34

10 35

896 102-41-4 GND

36

OFFICE-7 AIR CONDITIONING

OFFICE-7 AIR CONDITIONING

OFFICE-7 LTG & CEILING FAN

2-101-6 GND

LOAD(VA)

20676 21718 18176TOTAL CONNECTEDLOAD (VA)

PANEL SCHEDULE SDB3, MCB = 125A

OFFICE-8 LTG & CEILING FAN

OFFICE-7 OUTLETS

CORRIDOR-5/BATHROOM LTG& EXHAUST FANS

SPARE -- --

----SPARE

SPARE -- --

DORMITORY-1 LTG & CEILING FANS

2-41-4 GND

2640

DORMITORY-2 LTG & CEILING FANS

DORMITORY-1 AIR CONDITIONING

DORMITORY-1 AIR CONDITIONING

DORMITORY-1 AIR CONDITIONING

DORMITORY-2 AIR CONDITIONING

DORMITORY-2 AIR CONDITIONING

OFFICE-8 AIR CONDITIONING

2-41-4 GND

810

-- -- SPARE

DORMITORY-1 LTG & CEILING FANS

TOTAL DEMAND LOAD (VA): 70,570TOTAL CONNECTED LOAD (VA): 60,570 TOTAL DEMAND (AMPS): 107.2

LOAD(VA)

DORMITORY-1 OUTLETS

SPARE -- --

OFFICE-10 LTG, CEILING AND EXHAUST FANS

OFFICE-7/OFFICE-10 OUTLETS

SPARE -- --

DORMITORY-1 OUTLETS

ELECTRICAL ROOM OUTLETS

SPARE -- --

DORMITORY-2 OUTLETS

----SPARE

-- -- SPARE

---- SPARE

CORRIDOR-6/CORRIDOR-7/ELECTRICAL ROOM-2 LTG

-- -- SPARE

0

----SPARE

0

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 30: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-606

X

PA

NE

L

SC

HE

DU

LE

S

V

FED FROM: MDB

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 36

CABLE SIZE: 4-70mm, 1-16mm GND

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

NEMA TYPE 1 ENCLOSURE, 130A BUS

LOCATION: ELECTRICAL ROOM FIRST FLOOR2 2

100% NEUTRAL

CONTINUOUS (A): 130

AIC RATING (A): 22000FAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 2640 2640

1650

3536

19

3090

930

758

6250

7640

4646

7500

2310

7500

1250

8890

5640

3750

4466

2-41-4 GND

16

2 16

3 10

42-41-4 GND

10 450

52-41-4 GND

10 930

62-41-4 GND

10 758

7 10

8 10

92-41-4 GND

16 2640

102-41-4 GND

10 896

11 10

12 16

SPARE -- --

13 16

14 16

152-41-4 GND

16 2640

162-41-4 GND

16 2640

17 16

18 10

16

16 20

2640 162-41-4 GND

21

2640 162-41-4 GND

22

10 23

10 24

10 25

6250 402-101-6 GND

26

5000 322-101-6 GND

27

3750 252-61-6 GND

28

7500 452-161-6 GND

29

16 30

7500 452-161-6 GND

31

1250 162-61-6 GND

32

40 33

20 34

25 35

3750 252-101-6 GND

36

LOAD(VA)

23516 21330 27600TOTAL CONNECTEDLOAD (VA)

PANEL SCHEDULE SDB4, MCB = 130A

DORMITORY-4 AIR CONDITIONING

DORMITORY-4 AIR CONDITIONING

OFFICE-9 AIR CONDITIONING

2-101-6 GND

6250

2-61-6 GND

3000

TOTAL DEMAND LOAD (VA): 83,384TOTAL CONNECTED LOAD (VA): 72,446 TOTAL DEMAND (AMPS): 126.7

DORMITORY-4 LTG & CEILING FANS2-41-4 GND

896

CORRIDOR-8 LTG

OFFICE-9 LTG & CEILING FAN

DORMITORY-4 LTG & CEILING FANS

OFFICE-9 OUTLETS2-41-4 GND

2310

SPARE -- --

SPARE -- --

DORMITORY-3 LTG & CEILING FANS2-41-4 GND

716

BATHROOM-2 SPACE HEATER

OFFICE-10 AIR CONDITIONING

DORMITORY-4 AIR CONDITIONING

WATER HEATER

DORMITORY-3 AIR CONDITIONING

DORMITORY-3 AIR CONDITIONING

2-101-6 GND

3750

LOAD(VA)

SPARE-- --

SURFACE MOUNTED

DORMITORY-4/CORRIDOR-8 OUTLETS

2-41-4 GND

1650

BATHROOM-2 LTG & EXHAUST FANS

SPARE

SPARE --

-- --

--

OFFICE-7/OFFICE-9 OUTLETS

CORRIDOR-5/BATHROOM-2/BATHROOM-3OUTLETS

CORRIDOR-7/DORMITORY-2 OUTLETS

SPARE -- --

SPARE----

-- -- SPARE

DORMITORY-3 OUTLETS

DORMITORY-4/DORMITORY-3 OUTLETS

-- -- SPARE

SPARE----

-- -- SPARE

BATHROOM-3 SPACE HEATER

0

SPARE

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 31: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-607

X

PA

NE

L

SC

HE

DU

LE

S

VI

FED FROM: MDB

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

2 2

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 310 1630

1770

990

1320 7

130

990

2-41-4 GND

10

2 10

3 10

42-41-4 GND

10 130

5 10

62-41-4 GND

16 990

162-41-4 GND

16 8

990 162-41-4 GND

9

16 10

10 11

10 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

2-41-4 GND

1320

TOTAL DEMAND LOAD (VA): 5,510

SPARE----

PANEL SCHEDULE SDB5, MCB = 20A

STORAGE-2 LTG & EXHAUST FAN

CORRIDOR-9 LTG2-41-4 GND

450

SPARE -- --

STORAGE-3 LTG & EXHAUST FAN

SPARE -- --

CORRIDOR-9 OUTLET

STORAGE-2 OUTLET

STORAGE-2 OUTLET

STORAGE-3 OUTLET

SPARE----

LOCATION: CORRIDOR-9 ROOF FLOOR

1760 1770 1980

TOTAL CONNECTED LOAD (VA): 5,510

LOAD(VA)

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

CABLE SIZE: 4-25mm, 1-10mm GND

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

RECESS MOUNTED

2 2

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 900 3400

5256

7

3250

1980

5400

10

2 10

3 16

4 16 2000

5 16

6 16 1650

20

32 8

10 9

16 10

16 11

25 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

TOTAL DEMAND LOAD (VA): 22,794 TOTAL DEMAND (AMPS): 34.6

PANEL SCHEDULE SDB6, MCB = 63A

6650 7236 6720

LOCATION: RECEPTION BUILDING OFFICE-1

1980

OFFICE-1 AIR CONDITIONING

1250

TOTAL CONNECTED LOAD (VA): 20,606

LOAD(VA)

EXTERIOR LIGHTS (CONTROLLED BY PHOTOCELL)

SPACE HEATER

--

-- -- SPARE

BATHROOM EXHAUST FAN, OFFICE-1,OFFICE-2 CEILING FANS

256 5000

SPARE--

OFFICE-2 AIR CONDITIONING3750

OFFICE-1, BATHROOM OUTLET

OFFICE-1, OFFICE-2 OUTLET

2500 ELECTRIC WATER HEATER2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-101-10 GND

2-41-4 GND

2-61-6 GND

SPARE------

CABLE SIZE: 4-6mm, 1-4mm GND

BUILDING LTG

SURFACE MOUNTED

TOTAL DEMAND (AMPS): 8.4

NEMA TYPE 1 ENCLOSURE, 20A BUS

CONTINUOUS (A): 20

AIC RATING (A): 10000

NEMA TYPE 1 ENCLOSURE, 63A BUS

CONTINUOUS (A): 63

AIC RATING (A): 10000

WATER PUMP2-41-4 GND

1320 1320

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 32: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-608

X

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 990 990

1250

1340

716

2 16

3 10

4 10

5 10

6 16

--

-- 8

-- 9

-- 10

-- 11

-- 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

TOTAL DEMAND LOAD (VA): 3,580

SPACE----

PANEL SCHEDULE SDB7, MCB = 25A

1250

SPARE -- --

SPACE----

990 1250 1340

TOTAL CONNECTED LOAD (VA): 3,580

LOCATION: GUARD TOWER 1

OUTLETS

SPACE HEATER

LIGHTING 1340

SPARE

SPARE

-- --

-- --

SPACE

SPACE

SPACE

SPACE-- --

--

--

--

--

--

--

--

--

--

TOTAL DEMAND (AMPS): 5.4

LOAD(VA)

2 2CABLE SIZE: 4-16mm, 1-6mm GND

PA

NE

L

SC

HE

DU

LE

S

VII

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 990 990

1250

1340

716

2 16

3 10

4 10

5 10

6 16

--

-- 8

-- 9

-- 10

-- 11

-- 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

TOTAL DEMAND LOAD (VA): 3,580

SPACE----

PANEL SCHEDULE SDB8, MCB = 25A

1250

SPARE -- --

SPACE----

990 1250 1340

TOTAL CONNECTED LOAD (VA): 3,580

LOCATION: GUARD TOWER 2

OUTLETS

SPACE HEATER

LIGHTING 1340

SPARE

SPARE

-- --

-- --

SPACE

SPACE

SPACE

SPACE-- --

--

--

--

--

--

--

--

--

--

TOTAL DEMAND (AMPS): 5.4

LOAD(VA)

2 2CABLE SIZE: 4-16mm, 1-6mm GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

CONTINUOUS (A): 25

AIC RATING (A): 10000

CONTINUOUS (A): 25

AIC RATING (A): 10000

SURFACE MOUNTED

SURFACE MOUNTED

NEMA TYPE 3R ENCLOSURE, 25A BUS

NEMA TYPE 3R ENCLOSURE, 25A BUS

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N

Page 33: ELECTRICAL LEGEND ELECTRICAL INDEX - diyala AL KHIDR LPS-ELECTRICAL 12 ma… · mdb1-ckt06 mdb1-ckt08 sdb6-ckt09 mdb1-ckt06 mdb1-ckt06 trench d1 trench d2 trench d2 trench d3 trench

X

NA

ME

NA

ME

NA

ME

xxxxc-xxx.d

gn

x:1

X

E-609

X

PA

NE

L

SC

HE

DU

LE

S

VIII

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 990 990

1250

1340

716

2 16

3 10

4 10

5 10

6 16

--

-- 8

-- 9

-- 10

-- 11

-- 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

TOTAL DEMAND LOAD (VA): 3,580

SPACE----

1250

SPARE -- --

SPACE----

990 1250 1340

TOTAL CONNECTED LOAD (VA): 3,580

LOCATION: GUARD TOWER 3

OUTLETS

SPACE HEATER

LIGHTING 1340

SPARE

SPARE

-- --

-- --

SPACE

SPACE

SPACE

SPACE-- --

--

--

--

--

--

--

--

--

--

TOTAL DEMAND (AMPS): 5.4

LOAD(VA)

2 2CABLE SIZE: 4-16mm, 1-6mm GND

FED FROM: MDB1

VOLTAGE: 380/220V, 50 Hz, 3 PHASE 4 WIRE

NUMER OF CIRCUITS: 12

MAIN: MAIN BREAKER AT TOP OF PANEL

SPECIAL: PLUG IN BREAKERS

100% NEUTRALFAULT (A):

DESCRIPTIONBREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.PHASE-A PHASE-B PHASE-C DESCRIPTION

BREAKER

(AMPS)

WIRE SIZE

(mm )2

CKT

NO.

1 990 990

1250

1340

716

2 16

3 10

4 10

5 10

6 16

--

-- 8

-- 9

-- 10

-- 11

-- 12

LOAD(VA)

TOTAL CONNECTEDLOAD (VA)

TOTAL DEMAND LOAD (VA): 3,580

SPACE----

1250

SPARE -- --

SPACE----

990 1250 1340

TOTAL CONNECTED LOAD (VA): 3,580

LOCATION: GUARD TOWER 4

OUTLETS

SPACE HEATER

LIGHTING 1340

SPARE

SPARE

-- --

-- --

SPACE

SPACE

SPACE

SPACE-- --

--

--

--

--

--

--

--

--

--

TOTAL DEMAND (AMPS): 5.4

LOAD(VA)

2 2CABLE SIZE: 4-16mm, 1-6mm GND

PANEL SCHEDULE SDB10, MCB = 25A

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

2-41-4 GND

CONTINUOUS (A): 25

AIC RATING (A): 10000

CONTINUOUS (A): 25

AIC RATING (A): 10000

PANEL SCHEDULE SDB9, MCB = 25A

SURFACE MOUNTED

SURFACE MOUNTED

NEMA TYPE 3R ENCLOSURE, 25A BUS

NEMA TYPE 3R ENCLOSURE, 25A BUS

US Army Corps

of Engineers

1

Descriptio

nDate

Appr.

Mark

2 3 4 5

SHEET NO.

OF

SEQUENCE NO.

ero

Accid

ents

ero

Tolerance

File

Na

me:

Plot Date:

Plot Scale:

PR

OJ

EC

T

NO.

1 2 3 4 5

A

B

C

D

A/

E

FIR

M

3

LIN

ES

PR

OVID

ED

DE

SIG

N

BY:

DR

AW

N

BY:

RE

VIE

WE

D

BY:

SO

L/

CO

NT

RA

CT

NO.

D

C

B

A

MO

NT

H

YE

AR

U.S.

AR

MY

EN

GIN

EE

R

DIS

TRIC

T

CO

RP

S

OF

EN

GIN

EE

RS

GU

LF

RE

GIO

N

SO

UT

H, IR

AQ

Gulf Region District

SM

AL

L

PO

LIC

E

ST

ATIO

N