electrical thread conversions for …electromec-uae.com/raxton/raxton catalogue 2009.pdf · thread...

13
ELECTRICAL THREAD CONVERSIONS FOR HAZARDOUS AREAS

Upload: vominh

Post on 24-Apr-2018

262 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

ELECTRICAL THREAD CONVERSIONSFOR HAZARDOUS AREAS

Page 2: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

2 3

Company Overview Contents

EExdAdaptors 4Insulated Adaptors 6Right Angle Adaptors 7Unions 8Male to Male & Female to Female Adaptors 9Reducers 10Stopping Plugs 12Breather Drain Plugs 14Compound Stopper Box/Adaptors 19

EExeAdaptors 5Reducers 11Stopping Plugs 13Breather - Drain Plugs 15Earth Lead Adaptors & Threaded Earth Plates 18

AccessoriesEarth Tags 16Washers 16Locknuts/Lockrings 16Screwed Nippling 17Bushes 17Shrouds 17Serrated (Shakeproof ) Washers 17

Technical InformationThread Dimensions Chart 20Raxton Part Number System 21Hazardous Area Information 22Ingress Protection Information 23

Raxton Limited have been manufacturers of Electrical Thread Adaptors, Reducers, Stopping Plugs and accessories since 1976. Today Raxton remain committed to products designed to solve the fundamental difficulties which exist due to the variety of thread forms currently in use within the electrical industry.

Problems caused by dissimilar threads can occur in both hazardous and industrial environments. Raxton products are fully approved to meet these requirements, being EExd and EExe certified as ATEX, CSA, IECE and GOST Standards.

Many products such as Cable Glands, Drain Plugs, Insulating and Earth devices have been added over the years. Raxton now has a worldwide distribution base for its extensive range.

Experience shows that our customers are unable to cope with extended deliveries. We recognise the need to respond quickly and have established a reputation throughout the industry for prompt despatch of orders, however large or small.

Raxton will continue to offer, alongside its standard range, a bespoke and specials manufacturing service to meet the needs of the market it serves.

Whilst the company continues to expand and develop, Raxton’s principal objective will always be to maintain its high standards of customer satisfaction.

Page 3: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

4 5

Adaptors EExd EExe Adaptors

ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94 M32 26.8 37.59 M40 33.5 47.24 M50 44.0 56.39 M63 55.2 70.10 M75 66.7 80.01

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X

CSA 1003277U

GOST POCC GB.M Л14.B00104

plAtingRaxton Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread variations produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating.

*

** Minimum 8 full threads parallel 5 full

threads taper

typE AB hEX

Raxton EExd Adaptors provide a means of connection between dissimilar thread forms or sizes. Certified Adaptors should be used following the basic rules in line with good engineering practice:- No more than one conversion Adaptor should be used at one time on any given cable entry.

Standard Adaptors have a hexagonal body, where space is a critical factor, Adaptors can be offered with a round body with a diameter equal to the A/F dimension of the standard item.

Raxton Adaptors are marked with the applicable approval number and size.

ThrEAd BOrE BOrE hEAd dIA hEAd A/F FEMALE NYLON METALLIC NYLON MM METALLIC MM M16 8.0 11.0 24.0 20.8 M20 12.5 14.3 27.5 23.4 M25 17.5 20.5 35.5 28.0 M32 24.5 26.8 41.0 37.6 M40 32.5 33.5 50.0 47.2 M50 42.5 44.0 60.0 55.9 M63 53.0 52.2 75.0 70.0 M75 64.0 66.7 85.0 80.0

QuAlitySIRA (0518) 02 ATEX M207

BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11

Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

Nylon: 30% Glass filled Nylon 66

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X

GOST POCC GB.M Л14.B00104

plAtingRaxton Metallic Adaptors are available in a variety of finishes

including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is

therefore not given a temperature rating. Nylon temperature range -20°c to 60°c

'O' ring -50°c to 100°c GF Nylon is UL rated @ H.B. @ 1.5mm

Raxton EExe Adaptors provide a means of connection between dissimilar thread forms or sizes. Certified Adaptors should be used following the basic rules in line with good engineering practice:- No more than one conversion Adaptor should be used at one time on any given cable entry. Stopping Plugs should be fitted directly into unused entries of the equipment and not into an Adaptor.

Metallic Adaptors are supplied with a hexagonal body as standard. Where space is a critical factor Adaptors with a round body can be offered the diameter is equal to the across flat dimensions of the hexagonal body. Nylon Adaptors are produced with a round body.

EExe Adaptors are supplied fitted with an ‘O’ ring to maintain the IP integrity of the installation.

Raxton Adaptors are marked with the applicable approval number and size.

Independently tested to IP68.

* Minimum length of thread 10mm

*

*

typE AJ rOund

typE AB hEX

typE AJ rOund

Page 4: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

6 7

EExd right Angle Adaptors

ThrEAd ASSEMBLY BOrE MALE BOrE hEIghT MM SIzE MM M16 45 11.0 9 M20 51 14.3 15 M25 57 20.5 20.8 M32 66 26.8 26.8 M40 75 33.5 33.5 M50 86 44.0 44 M63 101.5 55.2 55 M75 119 66.7 66.5

QuAlitySIRA (0518) 02 ATEX M207

BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11

Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Right Angle Adaptors are available in a variety

of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component

and is therefore not given a temperature rating.

Raxton Right Angle Adaptors provide a means of connection where protrusion space is limited whilst simultaneously, if necessary, converting the entry thread to that of a different type or reducing size and/or gender of the female thread.

Right Angle Adaptors can be supplied either with male or female thread entries, or alternatively with female to female thread entries and are marked with the applicable approval number and size.

Protrusion dimensions are shown in the table below.

typE fg MAlE-fEMAlE

typE fn fEMAlE-fEMAlE

* Minimum 6 full threads parallel 5 full threads taper

*

*

insulated Adaptors EExd

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104 Nylon: 30% Glass filled Nylon 66

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Insulated Adaptors are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating. Nylon temperature range max 135°c to -20°c min GF Nylon is UL rated @ H.B. @ 1.5mm

Raxton Insulated Adaptors provide a means to isolate the earth of the supply cable from the load equipment thus reducing the risk of damage to electronic equipment within the enclosure in the event of a short circuit to ground through the enclosure. Insulated Adaptors also reduce the problems of electrical noise on the armour affecting the clean earth required by some sensitive instruments. Single point grounding can reduce the circulating current that can cause heating of high capacity cables.

Cable gland and cable can still be earthed externally with the use of an earth tag fitted between the cable gland and the Insulated Adaptor.

Raxton Insulated Adaptors are marked with the appropriate approval number and size.

typE dB

* Minimum 8 full threads parallel 5 full threads taper

**

ThrEAd prOTruSION MM BOrE dIA MM M16 45 11.0 30 M20 45 14.3 42 M25 45 20.5 47 M32 45 26.8 54 M40 45 33.5 62 M50 45 44.0 77 M63 45 55.2 87 M75 45 66.7 102

Page 5: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

8 9

unions EExd EExd Male to Male andfemale to female Adaptors

QuAlitySIRA (0518) 02 ATEX M207

BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11

Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Male to Male and Female to Female Adaptors are

available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component

and is therefore not given a temperature rating.

Male to Male Adaptors provide a connection between two female threads of the same or dissimilar thread forms.

Female to Female Adaptors provide a connection between two male threads of the same or dissimilar thread forms.

In each case, thread combinations can reduce by one size of the same thread form or to the equivalent of another form. Eg M25 x M20 M25 x 1/2"NPT

Both Male to Male and Female to Female Adaptors are marked with the appropriate approval number and size.

ThrEAd prOTruSION BOrE dIMENSION MM A/F MM M16 53 11.0 30.5 M20 53 14.3 33.0 M25 53 20.5 37.6 M32 53 26.8 47.2 M40 53 33.5 56.0 M50 53 44.0 65.0 M63 53 55.2 80.0 M75 53 66.7 90.0

typE AX rOund

* Minimum 8 full threads parallel 5 full threads taper

* *

ThrEAd LENgTh BOrE dIMENSION MM A/F MM M16 38 11.0 18.0 M20 38 14.3 23.4 M25 38 20.5 28.0 M32 38 26.8 37.6 M40 40 33.5 41.3 M50 40 44.0 53.0 M63 42 55.2 70.0 M75 42 66.7 80.0

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Unions are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating.

Raxton Unions are designed to provide a running joint whilst eliminating exposed threads and are particularly suitable for use where a coupler would be impractical. Unions are available in a variety of thread forms and can be supplied with male to female or female to female thread entries. The female connection thread of the Union shall step not more than one size up from the male connection thread, or equal to one size up in the case of a thread gender change. Eg M20(M) to M25(F) or M20(M) to 3/4 NPT(F).

Raxton Unions are marked with the appropriate approval number and size.

typE fB MAlE-fEMAlE

# Flamepath in accordance with appropriate standard

#

*

*

typE fl fEMAlE-fEMAlE

typE Au hEX

* Minimum 8 full threads parallel 5 full threads taper

NB for chart below. Bore size on female products is root diameter of the thread.

NB for chart below. Bore size on female products is root diameter of the thread.

Page 6: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

10 11

reducers EExd

ThrEAd A/F MM

M16 19.0 M20 23.3 M25 28.0 M32 37.6 M40 47.2 M50 55.9 M63 70.0 M75 80.0

EExe reducers

QuAlitySIRA (0518) 02 ATEX M207

BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11

Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

Nylon: 30% Glass filled Nylon 66

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X

GOST POCC GB.M Л14.B00104

plAtingRaxton Metallic Reducers are available in a variety of finishes

including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 22 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component

and is therefore not given a temperature rating.

'O' ring -50°c to 100°c Nylon -20°c to 60°c

Raxton EExe Reducers effectively reduce the threaded entry diameter of an enclosure to accept a gland or fitting with a smaller thread. Reducers may also be supplied to accept smaller glands of alternative threads.

Following the basic rules in line with good engineering practices no more than one Reducer should be used at any one time. Stopping Plugs should be fitted directly into unused entries of the equipment and not into a Reducer.

Brass Reducers are supplied with a hexagonal head as standard where space is a critical factor Adaptors with a circular head can be offered with a diameter equal to the across flats dimension of the hexagonal head.

Nylon Reducers are designed with a circular head.

EExe Reducers are supplied with an ‘O’ ring to maintain the IP integrity of the installation.

Raxton EExe Reducers are marked with the applicable approval number and size.

Independently tested to IP68.

ThrEAd hEAd dIA hEAd A/F FEMALE NYLON MM METALLIC MM M16 22 19.0 M20 25 20.3 M25 30 28.0 M32 38 37.6 M40 46 47.2 M50 56 55.9 M63 70 70.0 M75 81 80.0

typE BJ rOund

typE BB hEX

* Minimum length of thread 10mm

*

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X

CSA 1003277U

GOST POCC GB.M Л14.B00104

plAtingRaxton Reducers are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 22 identifies the standard thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

Raxton EExd Reducers effectively reduce the threaded entry diameter of an enclosure to accept a gland or fitting with a smaller thread. Reducers may also be supplied to accept smaller glands of alternative threads forms.

Following the basic rules in line with good engineering practices no more than one Reducer should be used at any one time.

Standard item has a hexagonal head where space is a critical factor Reducers with a circular head can be offered having a diameter equal to the across flats dimension of the hexagonal head (see table below).

Raxton Reducers are marked with the applicable approval number and size.

typE BJ rOund

* Minimum 8 full threads parallel 5 full threads taper

*

typE BB hEX

NB for chart below. Bore size on female products is root diameter of the thread.

NB for chart below. Bore size on female products is root diameter of the thread.

Page 7: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

12 13

Stopping plugs EExd

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983 British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121 Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6 Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X

CSA 1003277U

GOST POCC GB.M Л14.B00104

plAtingRaxton Stopping Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating.

Raxtons' comprehensive range of Stopping Plugs are designed to close any unused entries in electrical equipment without revoking existing certification.

The range covers four design types:-

tAMpErprOOf plug typE CfTamperproof Plugs are inserted from the outside with the allen key towards the enclosure and then tightened from the inside to leave a flush finish to prevent unauthorised removal.

rX plug typE CBRX Plugs are inserted with the allen key pointing away from the box and tightened from the outside.

hEXAgOn hEAd plug typE CKHexagon Headed Plugs are inserted from the outside and fastened by means of a spanner. (Across flats dimensions are listed below).

ThrEAd rX & Tp dOME hEXAgON hEAd ALLEN kEY ALLEN kEY A/F MM M16 6 6 19.0 M20 10 10 23.3 M25 10 10 28.0 M32 10 10 37.5 M40 10 19 47.0 M50 10 19 56.0 M63 10 19 70.0 M75 10 19 80.0

Following the basic rules in line with good engineering practice Raxton Stopping Plugs should be inserted directly into the unused entry and not into a thread Reducer or thread Adaptor.

They can be fitted with a washer to increase the IP rating of the assembly

* Minimum 8 full threads parallel 5 full threads taper

*

* *

EExe Stopping plugs

QuAlitySIRA (0518) 02 ATEX M207

EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 or ISO 965 Pts 1&3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Mild Steel: BS970 PT3 230M07 Stainless Steel: BS970 PT3 316 S11

Aluminium: BS1474/1 6082 T4 or T6 BS2874:1986 CA104

Nylon: 30% Glass filled Nylon 66

ApprOVAlSSIRA 00ATEX1073U

IECEx SIR07.0010X (metalic only)

GOST POCC GB.M Л14.B00104

plAtingRaxton Metallic Stopping Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated,

Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 22 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component

and is therefore not given a temperature rating.

'O' ring -20°c to 60°c Nylon -50°c to 100°c

Raxton EExe Stopping Plugs are designed to close any unused entries in electrical equipment. Available either with a mushroom head or a hexagonal head they are supplied complete with an ‘O’ ring to ensure that the IP rating of the installation is maintained.

Raxton Plugs should be fitted directly into any tapped or untapped entry in the enclosure - mushroom headed plugs are fastened by means of an allen key.

Raxton EExe Plugs are marked with the appropriate approval number and size.

Tested to IP68

ThrEAd A/F dOME hEAd dIA MuShrOOM hEX pLug MM ALLEN kEY pLug MM M16 19.0 6 20.5 M20 20.8 10 25.0 M25 28.0 10 30.0 M32 37.6 10 38.0 M40 47.2 19 46.0 M50 55.9 19 56.0 M63 70.0 19 69.0 M75 80.0 19 81.0

*#

#

hEXAgOn hEAd typE CKHexagon Head Plugs are inserted from the outside and tightened with a spanner. They are fitted with an 'O' ring as a norm but can be used with a washer if preferred.

dOME hEAd plug typE CQCan be offered as an alternative to the Hexagon Headed version

dOME hEAd typE CQDome Head Plugs are inserted from the outside using an allen key. They are fitted with an 'O' ring as a norm but can be used with a washer if preferred.

10mm across flats for M16 to M32. 19mm across flats for M40 to M75

* 15mm Standard

Page 8: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

14 15

Breather - drain plugs EExd EExe Breather - drain plugs

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 and ISO 965 Pts 1 & 3 National Pipe Thread (NPT) to ANSI/ASME:1983

MAtEriAlSBrass: BS2874: 1985 CZ121 Stainless Steel: BS970 PT3 316 S11

ApprOVAlSSIRA 00ATEX1288U

IECEx SIR08.0127U

plAtingRaxton Metallic Drain Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

tEMpErAturE-50°c to 230°c

QuAlitySIRA (0518) 02 ATEX M207

BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Nylon: 30% Glass filled Nylon 66 Stainless Steel: BS970 PT3 316 S11

ApprOVAlSSIRA 00ATEX3074U

GOST POCC GB.M Л14.B00104

plAtingRaxton Metallic Drain Plugs are available in a variety of finishes

including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 22 identifies the standard thread

variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component

and is therefore not given a temperature rating.

'O' ring -50°c to 100°c

The Raxton Exd Breather/Drain Plug is designed to: 1) effectively drain moisture from an enclosure, 2) allow air from the enclosure to vent into the surrounding atmosphere thereby minimising moisture build up and 3) provide the explosionproof safety required by a hazardous area environment.

The Plug is fastened to the lowest point of the enclosure by means of a spanner.

The plug is an assembled item and must not be taken apart at any stage of installation.

The 'O' ring will seal against the enclosure face enhancing the I.P. rating of the Plug.

The Breather/Drain Plug has an impact resistance of 20 Nm and can operate at temperatures between -50°c to +230°c

Tested to IP66

Raxton EExe Drain Plugs effectively drain any moisture build-up present within the enclosure whilst allowing air in the enclosure to breathe with the surrounding atmosphere minimising moisture build up within the enclosure.

Fastened by means of an allen key the Drain Plug should be fitted at the lowest point of the enclosure.

The Drain Plug can be fitted:

a) into a chamfered plain hole using drainage washer and locknut or castellated locknut on the inside of the enclosure.

b) directly into a threaded hole provided that, if the thread protrudes, the drainage hole is visible.

The Drain Plug can be supplied with either a serrated washer and locknut allowing the condensation to drain whilst ensuring the Plug is shakeproof or with a castellated locknut.

The Drain Plug is fitted with an ‘O’ ring as standard ensuring that the IP integrity of the installation is maintained.

Raxton Drain Plugs are marked with the appropriate approval number and size.

Tested to IP66

ThrEAd hEX A/F ThrEAd LENgTh OAL M20 27.0 (1.062) 16 31 M25 31.75 (1.25) 16 31 1/2” NPT 27.0 (1.062) 20.0 35 3/4” NPT 27.94 (1.1) 20.0 35

typE CV

typE CtE

* 10mm Standard

*

ThrEAd dIAMETEr ALLEN hEAd MM kEY MM prOTruSION MM M20 25.4 10 14 M25 30.5 10 14 M32 38.0 10 14 1/2” NPT 25.4 10 14 3/4” NPT 30.5 10 14 1” NPT 38.0 10 14

typE CtA

*

* Minimum 8 full threads parallel 5 full threads taper

Page 9: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

16 17

Accessories Accessories

SCrEwEd nippling Supplied 50mm long as standard, alternative lengths can be supplied as required. Available in a variety of thread forms (see page 22). Materials include Brass, Mild Steel, Stainless Steel, Aluminium and Nylon. Metallic finishes can be plated to requirements.

COuplErS Available in round or hexagonal. Manufactured in Brass as standard, they can be supplied with either similar or dissimilar threads at each end in a wide combination of thread forms and sizes.

BuShES Male and Female Bushes are available in a variety of thread forms (see page 22). Materials include Brass, Mild Steel, Stainless Steel, Aluminium and may be plated to requirements.

ShrOudS Raxton offer a range of push on Shrouds which are used to minimise the risk of dirt or foreign substances gathering on the cable gland body and /or point of cable to the gland interface. Supplied as standard in black PVC they are suitable for all leading makes of glands.

SErrAtEd (ShAKEprOOf) wAShErS Raxton Serrated Washers are available in both Mild Steel Zinc plated and Stainless Steel and prevent the risk of attachments becoming loose when used in conjunction with a Locknut.

lOCKnutS/lOCKringSRaxton offer a large variety of Locknuts/Lockrings which are often recommended for securing cable glands, thread Adaptors or thread Reducers to a gland plate or into equipment. Locknuts are available in Brass, Mild Steel, Stainless Steel, Aluminium or Nylon.

EArth tAgSRaxton Earth Tags provide a means of connecting a flexible earth bond with the gland, thread Adaptor or thread Reducer in any required position whilst ensuring suitable earth continuity. Available in Brass, Aluminium and Stainless Steel and supplied self colour as standard additional plating is available if required.

wAShErSTo maintain the IP rating of the equipment Raxton offer a wide variety of entry thread sealing Washers and ‘O’ rings. Materials include Nylon, Teflon, Neoprene, Fibre, and Rubber. In addition Raxton can offer a non setting universal jointing sealant.

Page 10: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

18 19

Earth lead Adaptorsthreaded Earth plates EExe

QuAlitySIRA (0518) 02 ATEX M207 BVQI EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3 National Pipe Thread (NPT) to ANSI/ASME:1983

MAtEriAlSBrass: BS2874: 1985 CZ121 Stainless Steel: BS970 PT3 316 S11

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Earth Lead Adaptors/Plates are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not given a temperature rating. 'O' ring -50°c to 100°c

ThrEAd LENgTh EArTh LEAd X EArTh LEAd MM 300MM (MM2) M16 38 2.5 M20 38 2.5 M25 38 4.0 M32 38 6.0 M40 39 10.0 M50 39 16.0 M63 39 25.0 M75 39 25.0

EArth lEAd AdAptOrSRaxton EExe Earth Lead Adaptors allow for earth continuity to be maintained by providing an earth lead which can be terminated inside the enclosure. Earth Lead Adaptors are produced with an undercut and supplied complete with an ‘O’ ring to maintain the IP integrity of the installation. Earth Lead Adaptors are marked with the appropriate approval number and size.

thrEAdEd EArth plAtERaxton EExe Threaded Earth Plates are designed to ensure earth continuity when terminating brass glands into non metallic enclosure. The additional use of a locknut is recommended to ensure pressure is maintained with the wall enclosure. Threaded Earth Plates are marked with the appropriate approval number and size.

typE dg AdAptOrStypE dn rEduCErS

* Minimum length of thread 10mm

*

ThrEAd MATErIAL CABLE X EArTh pLATE SIzE (MM) 300MM (MM2) M16 22 2.5 M20 30.0 2.5 M25 32.0 4.0 M32 38.0 6.0 M40 50.8 10.0 M50 63.5 16.0 M63 76.0 25.0 M75 102.0 25.0

EExd Compound Stopper Box/Adaptor

QuAlitySIRA (0518) 02 ATEX M207

EN ISO 9001: 2000

thrEAd SpECifiCAtiOnIsometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3

Imperial (ET) to BS31:1940 (1979) National Pipe Thread (NPT) to ANSI/ASME:1983

British Standard Pipe (BSP) to BS21:1985 Pg to DIN 40430:1971

MAtEriAlSBrass: BS2874: 1985 CZ121

Stainless Steel: BS970 PT3 316 S11 Aluminium: BS1474/1 6082 T4 or T6

Aluminium Bronze: BS1400 1985 AB2 or BS2874:1986 CA104

ApprOVAlSSIRA 00ATEX1073U

GOST POCC GB.M Л14.B00104

plAtingRaxton Stopper Boxes are available in a variety of finishes

including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.

thrEAd idEntifiCAtiOnSelection Table on page 20 identifies the standard

thread variation produced and is designed to assist the user in the selection process.

tEMpErAturEThe item is classified as a component and is therefore not

given a temperature rating. 'O' ring -50°c to 100°c

Raxton Compound Stopper Box is designed to seal conductors at the entry to the enclosure via conduit or to enable an existing compression gland to be converted to a barrier gland. This is achieved by forming a barrier between the individual insulated conductors within the cable to prevent an explosion within the enclosure. The Compound Stopper Box allows compound to be packed around individual insulated conductors. Assembly of the component compresses the packing material and distributes the compound evenly to effect a barrier at point of entry into the enclosure.

The Compound Stopper Box is supplied with compound in a pack, complete with making off instructions and gloves.

Raxton Compound Stopper Box is marked with the appropriate approval number and size.

typE Eg

* Minimum 8 full threads parallel 5 full threads taper

*

ThrEAd BOrE ThrEAd prOTruSION MIN MM LENgTh MM MM M16 7.20 15 32.0 M20 12.50 15 34.5 M25 18.25 15 34.5 M32 24.30 15 34.5 M40 30.00 17 35.0 M50 41.60 17 37.0 M63 53.25 17 37.0 M75 65.00 17 37.0

typE dK

Page 11: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

20 21

thread dimension Chart raxton part number System

FEMALE ThrEAd

MALE ThrEAd

M16

/5 /8” E

T

M20

/3 /4” E

T

M25

/1” E

T

M32

/11 /4

” ET

M40

/11 /2

” ET

M50

/2” E

T

M63

/21 /2

” ET

M75

/3” E

T

1 /2” N

pT/B

Sp

3 /4” N

pT/B

Sp

1” N

pT/B

Sp

1 1 /4” N

pT/B

Sp

1 1 /2” N

pT/B

Sp

2” N

pT/B

Sp

2 1 /2” N

pT/B

Sp

3” N

pT/B

Sp

3 1 /2” N

pT

4” N

pTThrEAdS pEr INCh pITCh BOrE SIzE

MAXMAJOr

dIAMETErMM

SIzE

16.93 1.5 11.0 16 M16

16.93 1.5 15.0 20 M20

16.93 1.5 20.5 25 M25

16.93 1.5 26.8 32 M32

16.93 1.5 33.5 40 M40

16.93 1.5 44.0 50 M50

16.93 1.5 55.2 63 M63

16.93 1.5 66.7 75 M75

14 1.81 14.3 21.34 1/2” NpT

14 1.81 20.5 26.67 3/4” NpT

111/2 2.20 26.8 33.40 1” NpT

111/2 2.20 33.5 42.16 1 1/4” NpT

111/2 2.20 41.0 48.26 1 1/2” NpT

111/2 2.20 54.0 60.33 2” NpT

8 3.175 64.5 73.03 2 1/2” NpT

8 3.175 79.0 88.90 3” NpT

8 3.175 90.0 101.60 3 1/2” NpT

8 3.175 101.0 114.30 4” NpT

14 1.81 p T 15.5 14.3 20.96 1/2” BSp

14 1.81 17.5 16.3 22.91 5/8” BSp

14 1.81 21.5 20.0 26.44 3/4” BSp

11 2.31 26.8 25.5 33.25 1” BSp

11 2.31 35.0 33.0 41.91 1 1/4” BSp

11 2.31 41.0 39.0 47.80 1 1/2” BSp

11 2.31 53.0 50.0 59.61 2” BSp

11 2.31 66.0 62.0 75.18 2 1/2” BSp

11 2.31 77.0 73.0 87.88 3” BSp

CErTIFIEd reducers Adaptors Not Certified

dIgIT 1+2 COdE

AdApTOrS

M-F hEX AB

M-F rOuNd AJ

M-M AR

F-F hEX AU

F-F rOuNd AX

rEduCErSM-F hEX BB

M-F rOuNd BJ

pLugS

rX CB

TAMpErprOOF CF

hEX hEAd CK

dOME hEAd CQ

SLOTTEd CS

drAIN CV

INSuLATINg ANd

EArThINg

INSuLATEd M x F DB

INSuLATEd M x M DD

INSuLATEd F x F DE

EArTh LEAd M x F DG

EArTh pLATE DK

EArTh TAg DM

CABLE rETENTION

gLANd EB

STOppEr BOX M-F EG

STOppEr BOX F-F EK

AdApTINg AIdS

uNION M-F FB

uNION F-F FL

uNION M-M FE

rIghT ANgLE M-F FG

rIghT ANgLE F-F FN

rIghT ANgLE M-M FK

LOCkINg

LOCkNuTS GA

LOCkrINgS GB

SErrATEd WAShErS GC

LOCkNuT CASTELLATEd GD

I.p. AIdS

WAShErS HA

O rINgS HB

ShrOud HC

ACCESSOrIES

MALE BuSh LONg JA

MALE BuSh ShOrT JB

FEMALE BuSh JC

NIppLE JD

NIppLE LONg JE

NIppLE BArrEL JF

COupLEr rOuNd JG

COupLEr hEX JH

COupLEr FLANgE JJ

dIgIT 3 COdE

BrASS AALuMINIuM B

STEEL CCOppEr & NON-ASB

D

STAINLESS STEEL

E

pVC FNYLON BLACk GNYLON grEY H

SILICONE JNYLON BLuE K

LEAd LgLASS FILLEd

NYLONM

NYLON 66 NrEd FIBrE U

TEFLON PEpdM Q

NYLON WhITE RSpECIAL S

MALE dIgIT 4 + 5 FEMALE dIgIT 6 + 7

ThrEAd rEFErENCES AS TABLE BELOW

ISOMETrIC NpT BSp T BSp p

SIzE COdE SIzE COdE SIzE COdE SIzE COdE

M6 01 1/2" 42 1/2" 52 62

M8 02 3/4" 43 3/4" 53 63

M10 03 1" 44 1" 54 64

M12 04 1 1/4" 45 1 1/4" 55 65

M16 11 1 1/2" 46 1 1/2" 56 66

M20 12 2" 47 2" 57 67

M22 07 2 1/2" 48 2 1/2" 58 68

M24 08 3" 49 3" 59 69

M25 13 3 1/2" 86 4" 79 89

M28 09 4" 87 SpECIAL 50 60

M32 14 5" 88

Normally male thread is specified first (4+5) Female thread second (6+7) with items then both M-M or F-F sets of digits will be used

Pg & ET thread components are still available please consult sales

department for advice.

M38 05

M40 15

M50 16

M63 17

M75 18

M80 80

M90 81

M100 82

SpECIAL 10 SPECIAL 40

dIgIT 8 ApprOVALS

Atex EExde AAtex EExd DAtex EExe E

Mining group 1 M

CSA © Exd11C JCSA (uS) Class

1 zone 1 K

AExd 11C LIECEx Exd

1/11C N

IECEx Exe 1/11 Pgost Exde

11Cu T

gost Exde 1/11Cu U

gost Exd11Cu Vgost Exe11u W

ExAmPLES

PART NUmBER Adaptor Brass 1/2”NPT m20F EExd AB A 42 12 d = ABA4212d

Reducer GF Nylon m50 m 1”NPT F EExe BB M 16 44 E = BBM1644E

Locknut Brass - m63 - gA A 00 17 l = gAA0017

Hex Head Plug ST/ST 2”BSPT - GOST EExd 11CU Ck E 57 00 V = CkE5700V

All codes marked cover products which are not certified or have any associated approvals

Page 12: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

22 23

hazardous Area ingress protection information

firSt nuMBEr - duSt

0 Non-protected

SECOnd nuMBEr - wAtEr

Non-protected

501Protected against solid foreign objects of 50mm ø and greater.

The object probe, sphere of 50mm ø, shall not fully penetrate†

12.52Protected against solid foreign objects of 12.5mm ø and greater.

The object probe, sphere of 12.5mm ø, shall not fully penetrate†

3Protected against solid foreign objects of 2.5mm ø and greater.

The object probe, sphere of 2.5mm ø, shall not fully penetrate† at all.

4Protected against solid foreign objects of 1.0mm ø and greater.

The object probe, sphere of 1.0mm ø, shall not fully penetrate† at all.

5

Dust Protected.

Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of apparatus or to impair safety.

Dust-tight

No ingress of dust

† The full diameter of the object probe shall not pass through an opening of the enclosure

6

0

Protected against vertically falling water drops.

Vertically falling drops shall have no harmful effects.

1

Protected against vertically falling water drops when enclosure tilted up to 15º.

Vertically falling drops shall have no harmful effects when the enclosure is tilted at any angle up to 15º on either side of the vertical.

2

Protected against spraying water.

Water sprayed at an angle up to 60º on either side of the vertical shall have no harmful effects.

3

Protected against splashing water.

Water splashed against the enclosure from any direction shall have no harmful effects.

4

Protected against water jets.

Water projected in jets against the enclosure from any direction shall have no harmful effects.

5

Protected against powered water jets.

Water projected in jets against the enclosure from any direction shall have no harmful effects.

6

15CM MIN

1M

Protected against the effect of temporary immersion in water.

Ingress of water in quantities causing harmful effects shall not be possible when enclosure is temporarily immersed in water under standardised conditions of pressure and time.

7

Protected against the effect of continuous immersion in water.Ingress of water in quantities causing harmful effects shall not be possible when enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7.

8

TEMpErATurE CLASS MAXIMuM SurFACE TEMpErATurE (dEgrEES CELSIuS)

T1 450 T2 300 T3 200 T4 135 T5 100 T6 85

grOuping Of ElECtriCAl AppArAtuS fOr pOtEntiAlly EXplOSiVE AtMOSphErESgrOup i ELECTRICAL APPARATUS FOR MINING, TYPIFIED BY THE GAS METHANE (FIREDAMP) grOup ii ELECTRICAL APPARATUS FOR SURFACE INDUSTRY Group II may be further divided into three gas groups: IIA - Representative Gas Propane IIB - Representative Gas Ethylene IIC - Representative Gas Hydrogen Gas Group IIC covers the most hazardous gases and as such, apparatus marked IIC may be used in IIA and IIB applications.

ClASSifiCAtiOnS

prOtECtiOn COnCEptS

*in some countries the methods of protection a & q are allowed in Zone 1.

tEMpErAturE ClASSExplosion protected electrical apparatus must be designed and tested to ensure that the maximum surface temperature of any part(s) of the products are below the ignition temperature of the explosive atmosphere concerned. Group II electrical apparatus is divided into temperature classes according to the maximum permissible surface temperature of the apparatus. The preferable classification of temperatures is given in the following table:-

Unless otherwise specified the maximum ambient temperature is taken to be 400ºC.

Zone Type of protection allowed European Standard number

0 EEx ia - intrinsically safe apparatus or system EN50020, EN50039 Ex s - special protection (specifically certified for use in Zone 0)

1 Any type of protection suitable for Zone ). EEx d - flameproof enclosure EN50018 EEx ib - intrinsically safe apparatus or system EN50020, EN50039 EEx p - pressurised apparatus EN50016 EEx e - increased safety EN50019 EEx m - encapsulation EN50028

2 Any type of protection suitable for Zone 0 and/or 1. *EEx a - oil immersion EN50015 *EEx q - powder filling EN50017 Ex N - non-sparking ‘EN’ In course of preparation. (pr EN50021) Existing UK Standard is BS6941:1988

StAndArd iEC/En COdE prOtECtiOn COnCEpt ZOnEgAS duSt gAS duSt gAS duSt

60079-0 61241-0 General Requirements60079-1 Ex d Flameproof 1

61241-1 Ex tD Enclosure 20/21/2260079-2 61241-2 Ex p Ex pD Pressurised 1 21/2260079-5 Ex q Powder Filled 160079-6 Ex o Oil Filled 160079-7 Ex e Increased Safety 1

60079-11 61241-11Ex iaEx ib

Ex iaDEx ibD

Intrinsic Safety01

2021

60079-15

Ex nAEx nLEx nREx nCEx nP

Non-sparkingEnergy Limited

Restricted breathingEnclosed breakPressurisation

2

60079-18 61241-18Ex maEx mb

Ex maDEx mbD

Encapsulation01

2021

gAS duSt

ZOnE 0 20 Zone in which an explosive atmosphere is constantly present, or present for long periods. (Rough guide: hazard present for more than 1000 hours/year).

ZOnE 1 21 Zone in which an explosive atmosphere is likely to occur in normal operation. (Rough guide: hazard present between 10 & 1000 hours/year).

ZOnE 2 22Zone in which an explosive atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. (Rough guide: hazard present for less than 10 hours/year). Guidance in the classification of hazardous areas is given in BS EN 60079-10:1996, IEC79-10.

Page 13: ELECTRICAL THREAD CONVERSIONS FOR …electromec-uae.com/Raxton/Raxton Catalogue 2009.pdf · ThrEAd MALE ThrEAd FEMALE ThrEAd MAX BOrE MM A/F dIMENSION MM M20 14.3 23.37 M25 20.5 27.94

raxton limitedWestgate, Aldridge, West Midlands WS9 8FStel: +44 (0) 1922 450400 fax: +44 (0) 1922 450401 Email: [email protected] web site: www.raxton.co.uk

ISSUE 09

A38

A38

A38

A38

A38

A38

A5

A5

A5

A5

A5A5

A5

A452

A452

A452

A452

A454A454

A34A5127

12

10

9

2

1

7

6 8

9

10

6

5 4a

77a 4

8

10a

M6

M6

M6M5

M5

M6

M42

M54

M42

LIChFIELd

ALdrIdgE

BIrMINghAM

dudLEY

WOLVErhAMpTON

WALSALLTAMWOrTh

WestBromwich

SuttonColdfield

Brownhills

Cannock

WALSALL rOAd B4154 pELSALL LANE B4154

B4152

B4152 NOrThgATE B4152

STuBBErS grEEN rOAd LEIghWOOd rd

BArN LANE WESTgATE WhArF ApprOACh

BArNS

LANE

duMBLEdErrY LA pAddOCk LA

A454 ALdrIdgE rd A454 WALSALL rd

A45

4

A454 LITTLE ASTON rd A4

61

LIC

hFIEL

d rOA

d

A46

1

LICh

FIELd

rOAd

A

461

dAW ENd LANE B4154 BOSTY LANE B4154

WITErLEY LANE