![Page 1: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/1.jpg)
Electricity Generation III GEOS 24705/ ENST 24705
Copyright E. Moyer 2012
![Page 2: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/2.jpg)
Direct current (DC)
Proponent: Edison Advantages: • Understandable • Availabe motors • Charges ba5eries • Available meters
Disadvantages • Cannot transform
voltage easily
Commercializa8on • London 1882 • New York 1882
(both coal) Early DC generator, “long-‐legged Mary Anne”, 1884
Also invented: • Lightbulb
(commercial) • Phonograph • Improved
telegraph
![Page 3: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/3.jpg)
Alternating current (AC) Proponent: Tesla (former Edison engineer) Advantages: • Transforms voltage
easily Disadvantages • No reliable motors
available • No ba5ery charge
Commercializa8on • Ames hydro: 1891 • Chicago coal: 1893 • Niagara hydro: 1895
AC dynamo, Chicago 1893
Also invented: • Induc8on AC motor • Radio communica8on • Wireless energy transmission
![Page 4: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/4.jpg)
Edison vs. Tesla: “war of the currents”
DC Edison’s company: General Electric, founded 1890, now ranked (Forbes, 2009) the largest company in the world. Precursor: Edison Illuminating Co., 1880 Technical achievement: First steam-powered electricity & electric utility, 1882, first U.S. transmission standard, multiple power plants (1.5 mi. transmission) (for lighting only) PR stunt: invented (AC) electric chair, attempted execution, 1890
AC Tesla’s company: Westinghouse Electric Company, founded 1886, now (after purchase of CBS)
knows as CBS Corp. (sold power generation to Siemens, itself provider of first electric street lighting in 1881). Hired first woman electrical engineer in 1890s.
Technical achievement: long-distance transmission of hydropower at Niagara
Falls to factories in Buffalo New York, 1895 (25Hz) PR stunt: lit Chicago World’s Fair, 1893
![Page 5: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/5.jpg)
Electric lighting common only a decade after invention
W.L. Sontag, 1895, "The Bowery at Night"
Individual private grid systems operation on their own standards, DC or AC from 25-133 Hz
![Page 6: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/6.jpg)
Edison vs. Tesla at 1893 Chicago World’s Fair
Tesla’s system already had most characteristics of the modern electricity system in 1893.. World’s Fair + choice at Niagara 2 years later committed us to AC Comparatively little evolution after choice was made – standardization of frequencies.
![Page 7: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/7.jpg)
First commercial AC generating stations
1) Used reciprocating engines rotating at around 2000 rpm (33 Hz)
2) Turn generators via belt drives
3) AC frequency didn’t matter much – each grid was separate, and electricity was used mostly for lighting anyways (where frequency doesn’t matter)
Early commercial AC generating station
![Page 8: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/8.jpg)
Industrial generation design specs
• Generator should be large for heat dissipa8on
• No sliding mechanisms that carry big current: current carried in stator
• Magnet in stator, use electromagnet for bigger B-‐field
• Voltage much higher than 110 V to minimize resis8ve hea8ng
• Many loops to increase voltage and power output
![Page 9: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/9.jpg)
Generators are virtually unchanged in 100 yrs
Stator, 3-phase generator, Brakpan, South Africa, 1897. Photo: Siemens
Stator, 3-phase generator, Wellluck Co., China, 12.5 MW, 2010
![Page 10: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/10.jpg)
Rotor carries electromagnet
Small Hydro Generator rotor - Rotor Assembly Area - Alstom Hydro
Manufacturing site in Galindo (Spain) copyright © 2010 M. Monteaux for Alstom
Old mill rotor (source unknown)
![Page 11: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/11.jpg)
Turbo-generator power grew very quickly (though seems to be leveling off)
From Vaclav Smil, “Energy at the Crossroads”
* Requires growth not just in generators but in turbines that power them * exponential growth in several stages * topping-out of steam P and T ca. 1960
![Page 12: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/12.jpg)
First major hydropower station, Niagara Falls, 1895
Adams power station, 10 5MW AC generators. Photo: Tesla Society
![Page 13: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/13.jpg)
Hoover Dam hydropower station, upgraded 1961
17 generators, average 120 MW. Photo: source unknown
![Page 14: Electricity Generation III GEOS 24705/ ENST 24705geosci.uchicago.edu/~moyer/GEOS24705/2012/Notes/Slides...First commercial AC generating stations 1) Used reciprocating engines rotating](https://reader033.vdocument.in/reader033/viewer/2022051917/6008d66e44107f5e585c8758/html5/thumbnails/14.jpg)
Tesla’s AC is “three-phase”
3-phase generation animation
(http://www.koehler.me.uk/animation/e_and_m_3phase_gen.htm)