4 Electrics for Rolling Stock
Catalogue F184 :: Multipole switchgear, SD, SE, SDE, SCO series
IndexCatalogue F184 :: Multipole switchgear, SD, SE, SDE, SCO series 1
SD, SE, SDE, SCO Multipole switchgear for voltages up 600 kV to 3 kV 2
Applications 2
Standards 2
Features 3
Ordering code 3
Specifications 4
Switching chamber 5
Switching chamber Disconnecting, change-over, earthing 5
Switching chamber Earthing 5
SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram 6
SD/SE/SDE/SCO 03 MG xxx xx Dimension diagram 6
SD/SE/SDE/SCO 03 ML xxx xx Dimension diagram 7
SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram 7
SE 03 MA xxx xx Dimension diagram 8
SE 01 MA xxx xx Dimension diagram 8
Mounting instructions, start up 9
Maintenance instructions 9
Safety instructions 9
Electrical Components and Systems for Railway Engineering and Industrial Applications 10
SD, SE, SDE, SCO series
Multipole switchgear for rail vehicles:
Disconnecting switches, Earthing Switches,
Disconnector with Earthing Switches, Change-Over-Switches
600 V to 3 kV
Catalogue F184.en
2
M MM M
AUX AUX
2 4 3 1 35
Train line
Supply25 kV 50 Hz /
15 kV 162/3 Hz
Line contactor
Main transformer
Traction 1
Traction 2
Subject to change
Applications
The switches of series SD, SE, SDE and SCO have a modular design and can be used for the function disconnect, earthing, disconnect and earthing as well as switching between two circuits (change-over).Switching between the individual switch positions is permissible without load only.
The number of circuits can be individually adapted to the respective require-ments. A combination of the above-mentioned functionalities within one device is simple to implement. The modularity is given not only to the num-ber and functions of the switching chambers, but also to the possibilities of actuation by drive units.
Switchgear for rolling stock
Standards
SD, SE, SDE, SCO Multipole switchgear for voltages up 600 kV to 3 kV
Use of functions disconnect, earthing, and change over-switching in railway applications for all rolling stock for voltage range up to 3 kV max:
● Traction inverter
● Auxiliary inverter
● Train power supply lines
● EN 50155: Railway applications – Electronic equipment used on rolling stock
● EN 50121-3-2: Railway applications – Electromagnetic compati-bility – Part 3-2: Rolling stock – Apparatus
● EN 50124-1: Railway applications – Insulation coordination – Part 1: Basic requirements – Clearances and creepage distances for all electrical and electronic equipment
● EN 61373: Railway applications – Rolling stock equipment – Shock and vibration tests
Normen
● EN 60077-1: Railway applications – Electric equipment for rolling stock – Part 1: General service conditions and general rules
● EN 60077-2: Railway applications – Electric equipment for rolling stock – Part 2: Electrotechnical components – General rules
● EN 45545: Railway applications – Fire protection on railway vehicles.
● NF 16101/NF 16102: Fire test to railway components
1 DC link: interconnection of traction converters in the event of a fault
2 Transformer switch: switch for changing over from 25 kV 50 Hz auf 15 kV 162/3 Hz on main transformer
3 Disconnector and change over switch: changes output of a traction inverter to the auxiliary loads (if auxiliary inverter is broken)
4 Disconnecting and earthing of high voltage busbar(s)
5 Earthing of circuits inside inverters
Further configurations: disconnecting and earthing of various cir-cuits inside inverters according to customer requirements!
3
Subject to change
Features
Ordering code
Do you need support for a special application? Please contact us! We would be glad to assist you in the selection of the contactor that suits your application best.
The multipole switchgear on this catalogue are individual configurable for your application, but based on standard components.
● Modular, compact and rugged design
● Switching to different switching positions allowed without load only
● Nominal voltage 600 V DC up to 3 kV DC
● Conventional thermal current 500 A per switching chamber, parallel switching of switching chambers is possible for higher rated currents
● Configurable up to 10 switching chambers
● 2, 3 or 4 switching positions can be implemented, for variant linear motor maximal 3 positions
● Key locking systems by means of a key switches, square keys and/or padlocks are possible
● Auxiliary switches for all positions are provided
● Detection and indication of high voltage by means of HV sensor, optional
● Optional integrated high voltage sensors detects and indicates if high voltage circuit is under load by flashing of 3 red LEDs. It indicates AC and DC voltages from 40 V to 4.2 kV
● Mechanical interfaces such as front panel, housing and so on can be adapted to installation conditions of the E-containers, racks, etc.
● Easy and low cost maintenance: ● Easy inspection and low life cycles cost (LCC) ● Preventive maintenance – a proper greasing is required only.
This activity can be performed directly on train, special inspection points on the switching chamber are available
● Corrective maintenance – a service kit consisting 4 different spare parts is sufficient to repair switching chamber and/or active (mo-vable) components
Example: SD 03 MA 00 110 01
Series SD SE
SDE SCO
Disconnecting switch Earthing switch Disconnector and earthing switch, combined Change-over switch
Nominal voltage 03 Un = 3 kV DC
Drive unit / activation unit MA MG ML MP
Manual Motor-driven: motor gear unit Motor-driven: linear motor Pneumatic drive (upon request)
Switching capability, Making 00 Making: Without load
Control voltage 24 / 36 / 72 / 110 V DC
Special design Special design 1 Special design 2 Special design 3 Special design 4 Special design ...
01 02 03 04 ...
Running number of variants; list of special design which are not fixed in ordering code above, like: Design of front panel, different keylock systems,
number and configuration of the switching chambers, different installation variants
on-roof / in-roof, ...
Four different types of drive units are available:
1. Manually operated by lever, mechanical interface on customer request
2. Electrically operated by motor-gear-unit, end positions controlled by digital encoder
3. Electrically operated by linearmotor
4. Pneumatically operated drive (upon request)
Individual assembly of switching chambers / main contacts:
NO – Normally open contact
NC – Normally closed contact
CO – Change-over-switch
4
Subject to change
Specifications SD, SE, SDE, SCO series
Series Switch for
SD Disconnecting
SE Earthing
SDE Disconnecting and earthing
SCO Change-over
Switching chamberType of voltage DC, AC (f < 60 Hz) DC, AC (f < 60 Hz) DC, AC (f < 60 Hz) DC, AC (f < 60 Hz)
Number of fixed contacts, configuration 1 ... 10, NC / NO / CO 1 ... 20, NC / NO / CO 1 ... 20, NC / NO / CO 1 ... 20, NC / NO / CO
Nominal voltage Un 3,000 V 3,000 V 3,000 V 3,000 V
Rated operating voltage Ue 3,600 V 3,600 V 3,600 V 3,600 V
Rated insulation voltage UNm 4,800 V 4,800 V 4,800 V 4,800 V
Rated impulse withstand voltage UNi 25 kV 25 kV 25 kV 25 kV
Pollution degree PD3 PD3 PD3 PD3
Overvoltage category OV3 OV3 OV3 OV3
Conventional thermal current Ith 500 A *1 --- 500 A *1 500 A *1
Component category / class (IEC 60077-2) A4 / C2 A4 / C2 A4 / C2 A4 / C2
Making capacity, breaking capacity without load without load without load without loadRated short-time withstand current Icw T < 100 ms / T < 25 ms
4 kA / 50 kA
4 kA / 50 kA
4 kA / 50 kA
4 kA / 50 kA
Critical current range none none none none
Design
Contact blades, shape Contact blades, material
/ / Cooper, silver plated
/ / Cooper, silver plated
/ / Cooper, silver plated
/ / Cooper, silver plated
Fixed contacts, material Terminals Torque
Cooper, silver plated
Bolt, M820 Nm max.
Cooper, silver plated or stainless steel
Bolt, M820 Nm max.
Cooper, silver plated
Bolt, M820 Nm max.
Cooper, silver plated
Bolt, M820 Nm max.
Auxiliary contacts
Number / type 1 per position / S826 (Schaltbau snap-action switches, see catalogue D26) or *2
Contact material Silver
S826 switching capacity (T = 5 ms) 16 A @ 24 V DC; 13.5 A @ 80 V DC; 7 A @ 110 V DC
Terminals Terminal block, connector or *2
Drive unit
Motor voltage USM 24 / 36 / 72 / 110 V DC
Control voltage encoder USE 24 V DC
Tolerance motor and control voltage -30 % ... +25 % Us
Switching positions Manual: lever or *2 Motor gear unit with digital encoder Linear motor unit with digital encoder
4 max. sequence 1-2-3-4-3-2-1
4 max. sequence 1-2-3-4-1-2-3-4-... 3 max. sequence 1-2-3-2-1
Change over time Motor gear unit with digital encoder Linear motor unit with digital encoder
approx. 3 sec
approx. 3 sec, 8 sec max. *3
Terminals Terminal block, connector or *2
Interlock *2 Key lock switches / square key locks / key multiplier / pad locks / electromagneticMounting Mounting Position
4x Screw M10 or *2 horizontal, vertical
Degree of protection IP00
Mechanical endurance (IEC 60077-2, IEC 60077-2) 125,000 operating cycles
Vibration / Shock (IEC 61373) Category 1, Class BHousing Switching chamber Frame
Fiberglass reinforced plastic
Stainless steel or *2
Ambient conditions Operating temperature Storage temperature Altitude Humidity (EN 50125-1)
Manual: -50 °C … +40 °C / Motor gear unit/linear motor unit: -40 °C … +70 °C Manual: -50 °C … +70 °C / Motor gear unit/linear motor unit: -40 °C … +85 °C
< 2,000 m above sea level< 75 % im yearly average
Weight Manual Motor gear unit Linear motor unit
approx. 25 kg *4 approx. 35 kg *4 approx. 30 kg *4
*1 Per switching chamber *2 Customer specific / upon request *3 Depending on the number of switching chambers *4 Switchgear with 3 switching chambers, each additional plus approx. 3 kg
5
1
2 3
41
2 3
41
2
Contact bladeFixed contactTerminal M8 switching positions...switching positions...switching positions, 1 41 41 2
1
2 3
41
2 3
41
2
Contact bladeFixed contactTerminal M8 earthed position2 earthed position3 earthed position4
1
2
11
22
Contact bladeFixed contactTerminal M8 earthed position2 earthed position2 earthed position2
Subject to change
Switching chamber SD, SE, SDE, SCO seriesSwitching chamber Disconnecting, change-over, earthing SD, SDE, SCO series
Switching chamber Earthing SE series
● Disconnecting, change-over Switching chamber with 2 positions and 4 blade contacts
● Disconnecting, earthing Switching chamber with 2 positions and 4 blade contacts for earthing of 3 circuits
● Earthing Switching chamber with 4 blade contacts for earthing of 4 circuits
● Disconnecting, change-over, earthing Switching chamber with 4 positions and 3 blade contacts for earthing of 2 circuits
● Earthing Switching chamber with 3 blade contacts for earthing of 3 circuits
● Disconnecting, change-over, earthing Switching chamber with 4 positions and 2 blade contacts for earthing of 1 circuit
● Earthing Switching chamber with 2 blade contacts for earthing of 2 circuits
● Disconnecting, change-over Switching chamber with 4 positions and 3 blade contacts
● Disconnecting, change-over Switching chamber with 4 positions and 2 blade contacts
Shown are example configurations We are happy to realize your required switching configuration. Do not hesitate to contact us. Our aim is to implement your switching function by the optimum number of switching chambers.
The requested switching configuration will be realized by the: ● Number of switching chambers ● Number of switching positions ● Number and type of blade contacts ● Type of actuation
6
GROUND
SERVICE
Service position
Handle
4x mounting for screws M8
HV-A swichting chamber
HV-B swichting chamber
4x aux. switchesfeedback switching position(gray code)
Earthing terminal M8
High-voltage terminals M8
12x mounting for screws M6
Ground position
4x high-voltage indicators (LED)
4x high-voltage indicators (LED)
121
85.5
125 125
~265
.5
354
177
122 12210 10
1012
512
510
390
400
~311
.5
350
197
364
4x mounting M10
HV-A swichting chamberHV-B swichting chamberHV-C swichting chamber
4x aux. switchesfeedback switching position(gray code)
Earthing terminal M6
Motor
Gear
High-voltage terminals M8
Digital encoder9 ... 24 V DC
45 5.5
87.5
320
325.
5
312.
5
212.
5
352.
5
551.
2
270
Subject to changeDimensions in mm / Subject to change
SD/SE/SDE/SCO 03 MG xxx xx Dimension diagram SD, SE, SDE, SCO series
● Switchgear with 3 HV switching chambers and motor gear unit
SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram SD, SE, SDE, SCO series
● Switchgear with 2 HV switching chambers, manual actuation and HV indicators (LED)
7
4x mounting for screws M10
HV-A swichting chamberHV-B swichting chamberHV-C swichting chamber
Motor
4x aux. switchesfeedback switching position(gray code)
83 153 18
292
25430
300
20 20
340
320
High-voltage terminals M8
4x mounting for screws M10
2x aux. switchesfeedback switching position
Earthing terminal M6
Earthing terminal M8
Service position
Ground position
HV-A swichting chamber
High-voltage terminals M8
180
180
12
300
20
45°
260
320 213.5
33.5180
340
180
156
Handle. 125 Nm max.
2x Key locks
Subject to changeSubject to change / Dimensions in mm
SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram SD, SE, SDE, SCO series
SD/SE/SDE/SCO 03 ML xxx xx Dimension diagram SD, SE, SDE, SCO series
● Switchgear with 1 HV switching chamber, manual actuation and 2 key switches
● Switchgear with 3 HV switching chambers and linear motor unit
8
4x mounting for screws M10
Earthing terminal M6
2x aux. switchesfeedback switching position
Earthing terminal M8
High-voltage terminals M8HV-A swichting chamber
30
70 70
310 30
370
133.5
238
256
157
280
30
340
4x mounting for screws M10
HV-A swichting chamberHV-B swichting chamberHV-C swichting chamber
2x aux. switchesfeedback switching position
Earthing terminal M8
Service position
Ground position
High-voltage terminals M8
Handle. 250 Nm max.
216
12
240
320
20
45°
260
480
410
418
~300
280
Subject to change
SE 03 MA xxx xx Dimension diagram SE series
SE 01 MA xxx xx Dimension diagram SE series
● Switchgear with 3 HV switching chambers, manual actuation and 5 times key multiplier
● Switchgear with 1 HV switching chambers, manual actuation
9
Subject to change
Mounting instructions, start up SD, SE, SDE, SCO series
Maintenance instructions Safety instructions SD, SE, SDE, SCO series
● Do not exceed the current value stated in data sheet
● Do not operate any handling under electrical load
● Before maintenance operation ensure that the devices is completely deenergized
● Use only original spare parts
For detailed maintenance, safety and mounting instructions please refer to our operating manuals! Defective parts must be replaced immediately!
Start upBefore start up make sure that:
● The switch is properly secured to the chassis of car (check if screws are fixed)
● HV wires are properly connected at HV-contacts/terminals
● Low voltage wires are properly connected
● Earthing wires are properly connected to housing of device
Dimensioning instructions
● For connection of the main contacts with a thermal current of 400 A Schaltbau recommends the use of bus bars or wires with the following dimensioning:
● Cable cross-sectíon > 200 mm2 or ● bus bars with 25 x 8 mm
● Multipole disconnectors with function of earthing switch: Schaltbau recommends a cross-section of 50 mm2 min.
● For earthing of the housing Schaltbau recommends a green-yellow or transparent PE-wire with a minimal cable cross-section of 10 mm2
● The minimum distances to voltage-carrying parts must be observed! The dimension drawings are provided for this purpose. Please refer to our operating manuals.
● Weight of different variants depends on the number of switching chambers – each chamber more/less means higher/lower weight of approx. 3 kg.
● Depth of different variants depends on the number of switching chambers – each chamber more/less means a higher/lower depth of 40 mm.
● Do you need some help? For selecting the disconnector, earthing switch, change-over-switch that suits your application best do not hesitate to ask our advice.
Mounting position
● Horizontal and vertical installation are allowed!
Before energize the HV system, check if configuration of HV-contacts and blades accords with HV electrical schema. Use a multimeter!
with compliments:Schaltbau GmbHFor detailed information on our products and services visit our website – or give us a call!
Schaltbau GmbH Hollerithstrasse 5 81829 Munich Germany
Phone +49 89 9 30 05-0 Fax +49 89 9 30 05-350 Internet www.schaltbau-gmbh.com e-Mail [email protected]
Connectors
■ Connectors manufactured to industry standards
■ Connectors to suit the special requirements of communications engineering (MIL connectors)
■ Charging connectors for battery-powered machines and systems
■ Connectors for railway engineering, including UIC connectors
■ Special connectors to suit customer requirements
Snap-action switches ■ Snap-action switches with positive opening operation
■ Snap-action switches with self-cleaning contacts
■ Enabling switches
■ Special switches to suit customer requirements
Contactors ■ Single and multi-pole DC contactors
■ High-voltage AC/DC contactors
■ Contactors for battery powered vehicles and power supplies
■ Contactors for railway applications
■ Terminal bolts and fuse holders
■ DC emergency disconnect switches
■ Special contactors to suit customer requirements
Electrics for rolling stock
■ Equipment for driver's cab
■ Equipment for passenger use
■ High-voltage switchgear
■ High-voltage heaters
■ High-voltage roof equipment
■ Equipment for electric brakes
■ Design and engineering of train electrics to customer requirements
RoHS2011/65/EC
Schaltbau
Qua
lity y
ou can count on
Schaltbau
Qua
lity y
ou can count on
Schaltbau GmbH manufactures in
compliance with RoHS.
The production facilities of Schaltbau GmbH have been IRIS certified since
2008.
Certified to DIN EN ISO 14001
since 2002. For the most recent certificate visit
our website.
Certified to DIN EN ISO 9001
since 1994. For the most recent certificate visit
our website.
Electrical Components and Systems for Railway Engineering and Industrial Applications
We reserve the right to make technical alterations without prior notice.
For updated product information visit www.schaltbau-gmbh.com. Issued 01-2018F2137/1801/0 Printed in Germany