electrostatic charge removers
TRANSCRIPT
® ®
ELECTROSTATIC CHARGE REMOVERS
New choices for removing static charges
2
Reliable and efficient removal of static charges.X-rays are what make it possible!
PRINCIPLE OF STATIC CHARGE NEUTRALIZATIONPhotoionization mechanism
1 2 3 4 5Stable atom/molecule
Stable atom/molecule
Positive and negative ions are generated
Soft X-rays
Knocked out electron
Positively charged atom/molecule
Ion
Ion Ion
Ion
e-e-
When soft X-rays are emitted into air, they knock electrons out from stable atoms and molecules in the air leaving positive ions. These knocked out electrons then combine with other stable atoms and molecules to produce negative ions. Ions generated near an electrostatically charged target object are attracted to the target object by static electricity and neutralize the static charges on the target object. Other ions generated during this process return to their original atoms and molecules.
Hamamatsu PhotoIonizers and PhotoIon-Bars are electrostatic charge removers that use “photoionization” to apply low-energy soft X-rays to remove static electricity.Photoionization is an innovative ionization method that utilizes X-ray characteristics to neutralize static charges much more reliably and efficiently than other types of ionizers. Photoionization is effective in neutralizing static charges on objects, in environments, and under conditions that were impossible to treat up until now such as neutralization of static charges on complex structures and simultaneously neutralizing both sides of sheet materials. Since X-rays are emitted in a conical pattern, static charges over a wide area can be neutralized with just a single PhotoIonizer or PhotoIonBar. Hamamatsu PhotoIonizers and PhotoIonBars will completely eliminate static charges that cause serious problems in various manufacturing processes.
Soft X-rays are the type of light with very low energy compared to other X-rays and artificial radiation used for medical diagnostic imaging such as CT (computed tomography), PET (positron emission tomography), and X-ray photography. Soft X-rays are easy to handle and used in a wide variety of applications.
What are soft X-rays?
uuuufffafafafaiiiiiiiinnnnnn
Photoionization constantly generates ions uniformly over the entire range irradiated with soft X-rays. The high density of the generated ions helps remove all static charges very efficiently by neutralizing them to 0 volts.
Because photoionization generates an equal amount of positive and negative ions, there is NO risk of blowing an unbalanced amount of positive and negative ions onto target objects, and NO risk of causing “overshoot” that often occurs with conventional ionizers. So there is absolutely NO need to adjust the ion supply and so NO need to worry about overshoot. Overshoot: Phenomenon in which a target object is charged at an opposite polarity due to an unbalanced amount of positive and negative ions.
There is no need to blow air to move the generated ions to the target objects since ions are also constantly generated in the vicinity of target objects. This means that no dust flies up and there are no bad effects on target objects.Photoionization is also effective in removing static charges from lightweight components and powdery materials.
Photoionization is a clean process for removing static charges. It does not generate dust particles and electrostatic noise which might cause problems such as product defects and malfunctions in peripheral electrical devices.
Unlike corona-discharge ionizers whose discharge electrodes need frequent cleaning and periodic replacement, photoionization requires zero maintenance.The static charge neutralization performance is retained over a long period of time without any troublesome maintenance.
Completely removes all static charges No need for concern about “overshoot”
Needs no air flow that can badly affect the target objects Clean design that does not generate dust
NO maintenance required to keep charge neutralization performance Works great even in various special environmentsPhotoionization works well even in special environments including inert gases, dry air, etc. It eliminates problems at their source which has been impossible up to now
ArN2
0VZERO
NoAir
Clean
No Maintenance
3
Static charge removal or neutralization using conventional corona-discharge ionizers always brings problems such as residual static charges, dust generation, and frequently needed maintenance which are unavoidable due to its principle of neutralizing static charges. Hamamatsu PhotoIonizers and PhotoIonBars do not involve an electrical discharge to generate ions but use photoionization technology that directly ionizes atoms and molecules in the air by irradiating them with soft X-rays. This photoionization technology eliminates all problems associated with conventional ionizers and ensures highly efficient and reliable removal of static charges.
From static charge neutralization performance to maintainability, “photoionization” completely eliminates the root causes of problems thought impossible to solve up to now!
A great feature of photoionization using soft X-rays is that it can remove static charges from any type of object without any bad effect on the object. Due to high versatility and ease-of-use, Hamamatsu PhotoIonizers and PhotoIonBars are used in a wide range of application fields and help solve the problems caused by static electricity to boost the throughput and yield rate in manufacturing processes.
Effectively removes static charges from any object in any place.Widely used in various application fields due to high versatility and ease-of-use.
4
Liquid crystal and organic EL displaysThe size and resolution of liquid crystal and organic EL displays keep on increasing, so appropriate measures must be taken to remove static charges on a larger surface area. PhotoIonizers and PhotoIonBars cover a wide area to neutralize static charges down to 0 volts to eliminate problems caused by static charges in production processes, including defects caused by particle adhesion and electrostatic discharge (ESD) that may occur during component pickup.
SemiconductorsThe increasing degree of miniaturization and circuit integration of semiconductor devices makes them more vulnerable to static charges. This makes it essential to take measures against static charges since they damage or destroy internal circuitry or cause device defects due to particle adhesion or from electrostatic discharge (ESD) that may occur during pickup.
PrintingStatic electricity charged on paper and films can cause ink to bleed, splatter or spatter as well as particle adhesion and paper alignment errors creating serious printing problems. Hamamatsu PhotoIonizers and PhotoIonBars revolve those problems stemming from static charges and help maintain the desired production efficiency and yield rate in the printing process.
5
PowderElectrostatically charged powder particles tend to easily adhere to nozzles and containers, which prevents packing and conveying powder in uniform amounts and causes serious problems such as drops in production efficiency and yield rates. Photoionization needs no air flow to remove static charges from powder particles and so can solve such problems that were impossible for conventional ionizers to handle.
FilmsStatic electricity accumulates on the surface of films where they repeatedly make and break contact. An especially large amount of static electricity accumulates on films near the feed and take-up rollers. Hamamatsu PhotoIonizers and PhotoIonBars neutralize the stored static charges that might otherwise emit sparks and damage (perforate) films or cause product defects due to particle adhesion or poor conditions in the work environment.
Rechargeable batteriesStatic electricity is likely to occur in a low humidity environments such as dry cleanrooms on production lines for products such as for rechargeable batteries, so sufficient measures must be taken to neutralize static electricity. PhotoIonizers and PhotoIonBars can be used at these places to remove static charges that might damage (perforate) separator films or cause particle adhesion, thus preventing product defects and increasing the yield rate.
Coating/paintingCoating and painting are utilized in countless applications including metal and plastic automotive parts. Static charges on such parts can cause coating materials to bleed, splatter or spatter and also cause particle adhesion, creating problems with coating and painting. PhotoIonizers and PhotoIonBars can prevent such problems and thus improve coating and painting quality.
6
® ®
A wide lineup of electrostatic charge removers
L12645 L9873
Innovative electrostatic charge removers using “photoionization” by low-energy soft X-raysOur lineup includes products with features optimized for various applications so choose the one that best suits your application.
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
7
L11754 L12536
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
8
Standard model having built-in reliability and long record of high performance
The L12645 is a standard model of PhotoIonizer that has eliminated many problems caused by static charges. The L12645 is designed to provide a good balance of charge neutralization speed, installation flexibility, low initial costs, and ease of X-ray shielding, making it ideal for removing static charges from a wide range of objects, in environments, and under conditions.
L12645®
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
9
The C11952 controller is capable of controlling up to 4 PhotoIonizer heads (L9491) at the same time. It is ideal for removing static charges from large objects with large surface areas or for using multiple heads on multiple production lines.
STATIC CHARGE REMOVAL PERFORMANCE
DIMENSIONAL OUTLINES (Unit: mm)
OPTIONS
Controller: C12646
Accessories
Control cable A9654-10 (10 m)Power cable (2 m)External control connector (15-pin D-sub)
Four-head controller C11952
PhotoIonizer head: L9491
TAPPA0068EE
TAPPA0106EC
20 84
850
1515
96 4.330
16 65
48.5
X-RAY EMITTING WINDOWCONNECTOR (FOR CONNECTION TO CONTROLLER)
1/4-20UNCDEPTH 8
2-M4DEPTH 8
Weight: Approx. 0.35 kg
BOTTOM VIEW
SIDE VIEWFRONT VIEW REAR VIEW
IONON
OFF
ACCESSORY HEADAC IN
MONITOR
REMOTE
I-PRO
POWER
140 8.83
828
120
31.6
5
20.8
EXTERNAL CONTROL TERMINAL (15-PIN D-sub)
CONNECTOR (FOR CONNECTION TO HEAD)
POWER INPUT CONNECTOR
POWER SWITCH ION ON SWITCH
!
Weight: Approx. 0.5 kg
SIDE VIEWFRONT VIEW REAR VIEW
Measurement conditionsStatically charged plate: 150 mm, 20 pFCharging voltage: 1 kV / 100 V Temperature: 25 °CHumidity: 50 %
Within 1 second
Within 2 second
Within 3 second
Within 4 second
Within 5 second
5 seconds or more
500 500
1200
1100
1000
500
900
400
800
300
700
200
600
100
010001000
CHARGE NEUTRALIZATION AREA (mm)
IRR
AD
IAT
ION
DIS
TA
NC
E (
mm
)
10
DC (24 V) model that operates without a dedicated controller
The L9873 is designed for mounting into manufacturing equipment. It operates on power supplied from the manufacturing equipment and is directly controllable by the manufacturing equipment controller or control system. So there is no need to prepare an additional controller and it easily mounts into small spaces.
L9873®
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
11
STATIC CHARGE REMOVAL PERFORMANCE
DIMENSIONAL OUTLINES (Unit: mm)
TAPPA0082JD
Accessories
Plug housing XHP-10Contact pin BXH-001T-P0.6
Measurement conditionsStatically charged plate: 150 mm, 20 pFCharging voltage: 1 kV / 100 V Temperature: 25 °CHumidity: 50 %
Within 1 second
Within 2 second
Within 3 second
Within 4 second
Within 5 second
5 seconds or more
500 500
1200
1100
1000
500
900
400
800
300
700
200
600
100
010001000
CHARGE NEUTRALIZATION AREA (mm)
IRR
AD
IAT
ION
DIS
TA
NC
E (
mm
)
PWR10987654321
ION
ILK
ALT
Weight: Approx. 0.4 kg
20
15
508
106 330
48.5
4-M3 DEPTH 5
X-RAY EMITTING WINDOW
XH CONNECTOR (JST) B10B-XH-A
2-M4 DEPTH 8
28
84
6516
XH CONNECTOR (JST) B4B-XH-A
SIDE VIEW
BOTTOM VIEW
FRONT VIEW REAR VIEW
1/4-20 UNC DEPTH 8
12
High-end model with the highest static charge removal performance
The L11754 PhotoIonizer is designed to boost static charge removal performance up to the maximum. This allows removing static charges on large objects with large surface areas in a short time, leading to big gains in productivity in the manufacturing process. The L11754 is also effective in removing static charges from objects that are heavily charged or moving at high speeds.
L11754®
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
13
STATIC CHARGE REMOVAL PERFORMANCE
DIMENSIONAL OUTLINES (Unit: mm)
PhotoIonizer head: L11755
Controller: C11756
TAPPA0098EC
TAPPA0099EC
Accessories
Control cable A10885 (20 m)Power cable (2 m)External control connector (25-pin D-sub)
110 169
120
180.8 5
2-M4 DEPTH 8
X-RAY EMITTING WINDOW
36
728
27
80
7.5 20 40 40
2546
.5
34.5 100
19.5 65 65
7-M4 DEPTH 10
Weight: Approx. 1.73 kg
SIDE VIEW
BOTTOM VIEW
FRONT VIEW REAR VIEW
2-M5 (FOR ONE-TOUCH FITTING)
CONNECTOR (FOR CONNECTION TO CONTROLLER)
IONON
High Power PhotoIonizer
F1LIFE TIME
ALERTPREVISION
PROTECTI-PRO OFF
F2
ENT
POWER
OFF
ON
ACCESSORY HEAD AC IN
Weight: Approx. 1.41 kgREAR VIEW
17421
200
SIDE VIEW
216 8.83
24
407.
5
FRONT VIEW
POWER INPUT CONNECTOR
CONNECTOR (FOR CONNECTION TO HEAD)ION ON SWITCHPOWER SWITCH
EXTERNAL CONTROL TERMINAL (25-PIN D-sub)
Measurement conditionsStatically charged plate: 150 mm, 20 pFCharging voltage: 1 kV / 100 V Temperature: 25 °CHumidity: 50 %
Within 1 second
Within 2 second
Within 3 second
Within 4 second
Within 5 second
5 seconds or more
2000 2000
3000
2000
1000
01000
IRR
AD
IAT
ION
DIS
TA
NC
E (
mm
)
300010003000
CHARGE NEUTRALIZATION AREA (mm)
14
Compact highly versatile model linkable with each other
The L12536 PhotoIonBar is a compact unit equipped with a DIN rail bracket allowing a flexible installation layout. A maximum of 10 units can be connected in a daisy chain according to the production process. Besides low cost and low power consumption, the L12536 offers an eco-friendly design using no harmful beryllium, thus making its disposal easy and safe.
L12536®
Low initialcosts
Ease of X-rayshielding
Installationflexibility
Charge neutralization speed
Chargeneutralization
area
TAPPA0103ED
4537
48
92
6016 16
ALERT LED
X-RAY EMITTING WINDOW
Weight: Approx. 0.22 kg
CONNCT CONNCT ALERT
30
4
CONNECTOR (FOR DAISY-CHAIN CONNECTION OR CONNECTION TO CONTROLLER)
CONNECTOR (FOR DAISY-CHAIN CONNECTION OR CONNECTION TO CONTROLLER)
Within 1 second
Within 2 second
Within 3 second
Within 4 second
4 seconds or more
500
600
400
300
200
100
0500400300200100500 400 300 200 100
CHARGE NEUTRALIZATION AREA (mm)
IRR
AD
IAT
ION
DIS
TA
NC
E (
mm
)
Measurement conditionsStatically charged plate: 150 mm, 20 pFCharging voltage: 1 kV / 100 V Distance between each PhotonIonBar: 100 mmTemperature: 25 °CHumidity: 50 %
15
Hamamatsu provides dedicated controllers and all cables needed for supplying power and controlling PhotoIonBars. Select whatever cable and length you need according to the task.
STATIC CHARGE REMOVAL PERFORMANCE
DIMENSIONAL OUTLINES (Unit: mm)
OPTIONS
▲Controller C12537
PLC: Programmable Logic Controller
Controller C12537Connection cables A12538-001/-005/-050/-1004-pin I/O cable A12538-050N/-100N
●Connection cables and 4-pin I/O cables
Type No. Cable lengthConnection
A12538-001
A12538-002
A12538-005
A12538-050
A12538-100
A12538-050N
A12538-100N
100 mm
200 mm
500 mm
5000 mm
10000 mm
5000 mm
10000 mm
PhotoIonBar - PhotoIonBar
PhotoIonBar – Controller C12537
PhotoIonBar – PLC
TAPP1084E01SEPT. 2018 IP
HAMAMATSU PHOTONICS K.K.HAMAMATSU PHOTONICS K.K., Electron Tube Division 314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, NJ 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: [email protected]: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: [email protected]: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: [email protected] Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: [email protected] Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509 031 00, Fax: (46)8-509 031 01 E-mail: [email protected]: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-93 58 17 33, Fax: (39)02-93 58 17 41 E-mail: [email protected]: Hamamatsu Photonics (China) Co., Ltd.: 1201 Tower B, Jiaming Center, 27 Dongsanhuan Beilu, Chaoyang District, 100020 Beijing, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: [email protected]: Hamamatsu Photonics Taiwan Co., Ltd.: 8F-3, No.158, Section2, Gongdao 5th Road, East District, Hsinchu, 300, Taiwan R.O.C. Telephone: (886)03-659-0080, Fax: (886)03-659-0081 E-mail: [email protected]
The L12542 is a VUV Ionizer designed to remove static charges in a vacuum which up to now has been very difficult. “Photoionization” by vacuum ultraviolet light ensures high static charge removal performance even in a vacuum and contributes to a better throughput and yield rate in various types of production processes.
RELATED PRODUCTSElectrostatic charge remover VUV Ionizer L12542
SPECIFICATIONS
PREVENTIVE MEASURES FOR X-RAY EXPOSURE
●Shield thickness
Parameter L12645Soft X-ray tubeDesign life
Input voltage
Power consumption (Max.)Operating temperature rangeStorage temperature rangeOperating humidity rangeStorage humidity range
External control
Applicable standards
NOTE: 1When using the C12537 optional controller, make sure the supply voltage is 100 to 240 VAC, single phase, 50/60 Hz.
Tube voltage (DC)X-ray emission angle
EMCSafety
Environment
AC100 V to AC240 VSingle phase 50 Hz / 60 Hz
11
Ion ON/OFF controlIon ON signal output, Error signals
9.5130
15 000
L9873
DC24 V
7
—
L125364.9120
15 000
DC24 V 1
4
—
UnitkV°h
—
W°C°C——
—
—
L1175415
13020 000
AC100 V to AC240 VSingle phase 50 Hz / 60 Hz
50
Ion ON/OFF controlIon ON signal output, Error signals
0 to +40-10 to +60
Below 60 % (no condensation)Below 85 % (no condensation)
IEC 61326-1:2012, Group 1, Class AIEC61010-1: 2010
RoHS directiveWEEE directive
Shielding material L12645SUS304 stainless steelAluminumPVC (polyvinyl chloride)Acrylic
* To check X-ray leakage from the shield, use a radiation detector such as a survey meter. Please consult us for details.
0.221.32.221.7
L9873 L125360.110.230.653.3
Unit
mm
L117540.47——
Safety precautions· Soft X-rays emitted from this product are harmful to human health. Handle carefully and never allow yourself get exposed to X-rays.· When using this product, place the head unit inside an X-ray shielded area and always install a safety interlock.
Key points for avoiding X-ray exposure are to isolate the X-ray irradiation area and not to enclose it. It is important that operators can visually recognize the X-ray irradiation area but cannot physically enter that area. When these conditions are met, X-ray shielding will prove sufficient even if there is an opening in the irradiation area.To avoid inadvertent exposure to X-rays, be sure to provide a safety interlock function that immediately cuts off X-ray emissions when the X-ray shielding door or panel is opened.
Legal regulations involving this productThis product must be used in compliance with health and safety regulations enforced to prevent bodily harm caused by ionizing radiation.Users of this product must be familiar with applicable laws that regulate use of X-ray emission devices. To obtain more information, refer to international or domestic laws and regulations on ionizing radiation and comply with the required procedures listed there.
Warranty periodThis product is guaranteed for one year from the date of delivery. The warranty is limited to replacement of the product. Even if within the warranty period, the warranty does not cover damage caused by misuse or accidents such as natural disasters.
* and PhotoIonBar are registered trademarks of Hamamatsu Photonics K.K.