elemental analysis of plant material
TRANSCRIPT
1
The Hebrew University of JerusalemThe Faculty of Agricultural, Food and Environmental Quality Sciences
Rehovot, Israel
Vasiliy V. Rosen, Ph.D., ZBM Laboratory [email protected]
Elemental Analysis of Plant Material
2
After Jones, 2001
1. Introduction
3
What do we analyze when we are analyzing plants?
Essential elements (major elements and micronutrients)
Toxic elements
Introduction
4
Essential ToxicMajor Micronutrient
s
Carbon (C)Oxygen (O)
Hydrogen (H)
Nitrogen (N) Phosphorus (P) Potassium (K)
Sodium (Na)Silica (Si)
Calcium (Ca) Magnesium (Mg)
Sulfur (S)
Boron (B), Chlorine (Cl)Copper (Cu)
Iron (Fe)Manganese (Mn)
Molybdenum (Mo) Zinc (Zn)
Nickel (Ni)Cobalt (Co)
Chromium (Cr)Selenium (Se)Vanadium (V)
Silver (Ag)Aluminium (Al)
Arsenic (As)Barium (Ba)
Berillium (Be)Cadmium (Cd)Mercury (Hg)
Lead (Pb)Lithium (Li)
And all micronutrients at
critical concentration
The role of chemical elements in plants (adopted from Munson R., 1997, and Macnicol R., 1985)
Introduction
5
The levels of major elements and micronutrients in mature leaf tissue (after Munson R., 1997)
Introduction
Parts per million = mg/kg
Percent
6
Introduction Concentration UnitsMajor Elements
% of dry weightgram per kilogram (g/kg)
Micronutrients and Toxic Elements
7
2. Analytical Chemistry Basics
Qualitative and quantitative analysis
Calibration and matrix
Limit of Detection and Limit of Quantitation
Accuracy and Precision
Analytical Chemistry Basics
Qualitative and Quantitative Analysis
Is there the analyte in the sample?
If yes, which one?
Qualitative Analysis
How much analyte is there?
Quantitative Analysis
ICP: ATOMIC EMISSION SPECTROMETRYAS QUANTITATIVE ANALYSIS
Unknown Sample
8
ICP : ATOMIC EMISSION SPECTROMETRYAS QUALITATIVE ANALYSIS
9
Analytical Chemistry Basics
Calibration CurveThe calibration curve is a plot of detector response as a function of concentration
(after Munson R., 1997)
10
Analytical Chemistry Basics
Matrix
Cd, 1 mg/L, in weak acid
Cd, 1 mg/L, in base
Analyte concentrations are equal, but intensities are different
11
Analytical Chemistry Basics
Limit of Detection
Limit of Quantitation
LOD is the concentration at which
we can decide whether an element
is present or not (Thomsen, 2003)
LOQ is the lowest concentration at
which a measurement is
quantitatively meaningful (Mitra,
2003)
LOD = 3*SDblank LOQ = 10*SDblank
LOQ = 3.3*LODorSD (or δ) – Standard Deviation
12
Analytical Chemistry Basics
Limit of Detection
Limit of Quantitation
LOD is the concentration at which
we can decide whether an element
is present or not (Thomsen, 2003)
LOQ is the lowest concentration at
which a measurement is quantitatively
meaningful (Mitra, 2003)
FDA, Elemental Analysis Manual, 2014
Method LOQ!!!
Analytical Solution Detection Limit
13
LOD and LOQ determination on ICP-OES
Observed LOD = <5 ppb
Observed LOQ = ≈ 10 ppb
Analytical Chemistry Basics
14
Analytical Chemistry Basics
Accuracy and Precision
Accuracy is how close a measured value is to
the actual (true) value.
Precision is how close the measured values are to each
other.
after http://www.mathsisfun.com
15
3. Plant Samples Pretreatment
Sampling Procedure
Decontamination
Drying
Grinding
16
Plant Samples Pretreatment
Sampling ProcedureWhat to sample?
Mature leaves exposed to full
sunlight just below the growing
tip on main branches or stems are
usually preferred (Jones B., 2001)
How much material to sample?
Depending on plant and
investigation goal – usually tens
(20-100) leaves or small plants
17
Plant Samples Pretreatment
Sampling Procedure
What DO NOT sample?
After Jones B., 2001
18
Plant Samples Pretreatment
Decontamination
Tap water
Detergent solution , non-phosphate
(0.1 to 0.3%)
Weak acid (HNO3 1%) – optional
Deionized water
Soil and dust particles: Fe, Al, Si
and Mg. Calcareous soils – Ca.
Liquide fungicides – Cu.
Nutrition solution (fertilizer) –
NPK, essential elements.
Investigator’s fingers - Cl
Contaminants Washing procedure
19
Plant Samples Pretreatment
Drying Put washed fresh samples in paper bag (or envelope). Do not use plastic
bag since plastic retains moisture, thus accelerating respiration and decay.
Refrigerate (4-5º C) or air-dry the fresh samples if delivery time to
laboratory is more than 12 h.
Fresh plant samples should be dried at 65-80º C in a ventilated oven at
least 24 h (usually 2-3 days) to stop the enzymatic activity. Higher drying
temperature can affect the dry weight.
20
Plant Samples Pretreatment
Grinding:particle size reduction Different types of mills are available: Jaw, Rotor, Cutting, Knife, Mortar,
Discs, Planetary Ball mills.
Material used: stainless steel, Zr2O, agate, porcelain.
Possible contaminants: Fe, Zn, Al, Na .
Planetary Ball Mill Rotor Mill
21
Plant Samples Pretreatment
Grinding: particle size units
Mesh is the number of openings in one inch of screen
If sample weight > 0.5 g – use 20 mesh sieve
If sample weight < 0.5 g – use 40 mesh sieve
22
4. Sample Preparation Techniques
Dry Ashing
Wet Digestion
Microwave-assisted acid digestion
23
Sample Preparation Techniques
Dry Ashing Analytes: B, Ca, Cu, Fe, Mg, Mn, P (but wet ashing is more recommended), K, Na, Zn.
Procedure: 500 mg of dry sample digested in porcelain crucible in muffle
oven during 4-6 h at 500º C . The ash dissolved in 1 N HCl.
Element determination: AAS, ICP-AES, UV-VIS (B, P).
Possible problems: easily volatilized elements are lost (Cl, S, As, Hg, Se);
boron (B) may be also volatilized; insoluble silicates are formed and decreased
recovery of other constituents, mainly trace elements; ashing temperature
higher than 500º C may decrease recovery of Al, B, Cu, Fe, K, Mn.
After Miller, 1998
24
Sample Preparation Techniques
Dry Ashing: Tips and Tricks If an ashing aid is needed, add either 5 mL HNO3, or 5 mL 7% Mg(NO3)2*6H2O
prior to muffel digestion. Dry on a hotplate and then digest.
To prevent Cl loss do the following: mix the sample with lime (CaO, ¼ of the
sample weight) and deionized water to make a thin paste. Dry the mixture, digest at
500º C, dissolve ash with HNO3 or H2SO4 (not HCl !!!)
The following acid mixtures may be used for ash dissolution: 300 mL HCl and
100 mL HNO3 in 1000 mL deionized water; Aqua Regia (concentrated HNO3 :HCL
1:3), HNO3 alone (less corrosive for metal parts of analytical instruments).
After Piper, 1950; Jones, 2001; personal experience
25
Sample Preparation Techniques
Wet Digestion Analytes: B (teflon vessels only), Ca, Cu, Fe, Mg, Mn, Mo, P, K, Se, Na, S, Zn, trace
elements.
Procedure: 500 mg of dry sample digested with some combination of four
acids: HNO3, HCl, H2SO4 and HClO4, with optional addition of H2O2. Digestion
is carried out in beakers on hot plate, in glass tubes on block, in open or closed
teflon vessels in microwave oven.
Element determination: AAS, ICP-AES, UV-VIS ( P, S).
Possible problems: HClO4 may react with organic material and result in an
explosion; in low Ca tissues CaSO4 may precipitate when H2SO4 is used;
contamination with B and Si when glass digestion tubes are used;
contamination with elements adsorbed by teflon.After Piper, 1950; Jones, 2001; Miller, 1998; personal experience
26
Sample Preparation Techniques
Wet Digestion: InstrumentsDigestion Block (open digestion)
Microwave Laboratory Ovens (closed digestion)
Ethos I, Milestone, Italy
Ultrawave, Milestone, Italy
Discover, CEM, USA
27
Sample Preparation Techniques
Wet Digestion: Tips and Tricks Samples with added acid(s) should be predigested at room temperature overnight
to avoid violent reaction at the start of heating. This is especially important for closed
microwave-assisted digestion.
H2O2 may contain Sn (tin) as a stabilizer. Do not use H2O2 if Sn is analyte.
Wet digestion on block has a high throughput, but closed vessel microwave-assisted
digestion demonstrates less element loss and contaminations, and it is less time-
consuming. Increase sample weight for the determination of trace metals (Cd, Cr, Ba etc) to 1 g.
Add internal standard (element that does not exist in your samples, Y or Sc) at the
start of digestion to control preparation process quality.
After Jones, 2001; Miller, 1998; personal experience
28
Sample Preparation Techniques
Wet Digestion: Tips and TricksInternal standard technique
29
5. Instrumentation used in plant analysis
X-ray fluorescence spectroscopy (XRF)
Atomic absorption spectroscopy (AA)
Flame Emission Spectrometry (Flame Photometry)
ICP-AES/MS
UV-VIS Spectrophotometry
Elemental Analyzer, Chloride Analyzer, Ion
Selective Electrodes etc.
30
Instrumentation
XRF: X-Ray Fluorescence Spectroscopy
Principle: Excitation of the sample by an X-ray source,
secondary radiation measurement.
Elements: with atomic number >8.
LOD: 100 mg/kg for major elements (light) and 1 mg/kg
for traces (heavy).
Sample Preparation: drying, fine grinding and
pressing.
Advantages: simple sample preparation; low cost;
portable instrument.
Disadvantages: spectral interferences; method is matrix-
dependent.
31
InstrumentationAAS: Atomic Absorption Spectroscopy
Principle: quantifies the absorption of ground state atoms in the
gaseous phase; the analyte concentration is determined by optics from the
amount of light absorption.
Elements: all the metals.
LOD: some µg/L (ppb), less than 1 ppb – with graphite furnace.
Sample Preparation: dry and wet digestion methods.
Advantages: highly specific for an element; minimum spectral
interferences; low-cost gases used (air+acetylene).
Disadvantages: ionization enhancement of the signal for elements
easily ionized when operating in the absorption mode, especially Na and
K; matrix interferences caused by viscosity or specific gravity differences
between sample and reference standard; elements analyzed one at a time.
32
InstrumentationFlame Emission Spectroscopy (Flame Photometry)
Principle: excitation of ground-state atoms by propane-
butane flame (2000-3000 ºC), electron loss by analyte atom,
when electron is recaptured, emission light of characteristic
wavelength is emitted.
Elements: Na and K; Li, Rb, Cs, Ca.
LOD: about 0.1-0.5 mg/L.
Sample Preparation: dry and wet digestion methods.
Advantages: simple, quick and inexpensive analysis; wide
dynamic range (0-100 mg/L); ideal for elements with low
excitation potential (Na and K)
Disadvantages: only some elements may be determined;
elements analyzed one at a time.
33
InstrumentationICP-AES: Inductively Coupled Plasma Atomic Emission
Spectrometry
Principle: electrons of excited atoms return to their ground-state and emit electromagnetic
radiation (light) at the wavelengths that are characteristic of the atoms that are excited. Argon
plasma is the source of excitation (about 10 000 K).
Elements: all the elements except gases and some non-metals (N, F, O, H).
LOD: some µg/L (ppb), less than 1 ppb – with MS detector (ICP-MS technology).
Sample Preparation: dry and wet digestion methods.
Advantages: minimum chemical interferences; four to six orders of magnitude in linearity
of intensity versus concentration; multielement capabilities; rapid analysis; accurate and
precise analysis; detection limits equal to or better than AAS for many elements.
Disadvantages: occurrence of spectral interferences; use of argon gas which can be
expensive; instrument is relatively expensive to purchase.
34
Instrumentation
UV-VIS SpectrophotometryPrinciple
Instrument
Applications:
Kjeldal digestion for total N: determination of NH4 and P in digestate;
Mo and B after dry or wet ashing;
NO3 in water extracts;
Metals: Cu, Fe, Mg, Mn and Zn determination.
b
35
InstrumentationJust a few words about….
Elemental Analyzer
Elements: C,H,N,S,O.
Digests finely grinded dry
samples.
Chloride Analyzer
Elements: Cl
Titrates Cl- with Ag2+.
Readout range: 10-999
mg Cl/L
Ion-selective Electrode
Elements: K+, Cl-, NO3-
Measures an electrical
potential on the ion
exchanger that is selective
to analyte ion.
36
Thank you for your attention!
Questions?