DESIGNER:
BAKER ARCHITECTURAL DESIGN
86 CEDAR STREET
BRAINTREE, MA 02184
Phone: (781)-858-1473
Email: [email protected]
COPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN, THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGNC
OWNER:
STRUCTURAL
ENGINEER:
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
CORCORAN & FERRENTINO RESIDENCE34 VALLEY BEACH AVENUE
HULL, MA 02045
ZB
A S
ET -
4/3
0/2
021
34 VALLEY BEACH AVENUE
HULL MA, 02045
CELL: (617)-842-3189
EMAIL: [email protected]
LARRY CORCORAN & LYNDA FERRENTINO
LOCUS MAP
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
DENOTES PROPOSED
FOUNDATION WALL ATOP FOOTING
FOUNDATION NOTES/LEGEND:
1) SEE "STRUCTURAL ENGINEERING AND WFCM ANALYSIS"
BOOKLET NO. 21-___ BY _________ ENGINEERING, llc
DATED april/__/2021 FOR ADDITIONAL NOTES AND DETAILS
2) ALL NEW FOUNDATION WALLS SHALL BE DAMP PROOFED
WITH A BITUMINOUS COATING.
3) 6 SQ. FT. OF VENTILATION REQUIRED FOR EVERY
1,500 SQ. FT. OF BASEMENT AREA.
4) OPENING FOR UNDER-FLOOR VENTILATION:
1 SQ. FT, OPENING/150 SQ. FT. OF CRAWL SPACE AREA
FRAMING NOTES/LEGEND:
1) SEE "STRUCTURAL ENGINEERING AND WFCM ANALYSIS"
BOOKLET NO. 21- BY ENGINEERING, LLC
DATED april/ /2021 FOR ADDITIONAL NOTES AND DETAILS
2) ALL FRAMING MEMBERS SHALL BE FASTENED IN ACCORDANCE WITH MANUFACTURERS
RECOMMENDATIONS AND THE COMMONWEALTH OF MASSACHUSETTS 780 CMR
WINDOW SCHEDULEQUANTITY ID LETTER MANUFACT. MODEL TYPE ROUGH OPENING COMMENTS
COMMENTSROUGH OPENINGTYPEMODELMANUFACT.ID LETTERQUANTITY
EXTERIOR DOOR SCHEDULE
2
ENGINEER
DENOTES DETAIL IN "STRUCTURAL ELEMENTS"
BOOKLET BY STRUCTURAL ENGINEER
DENOTES PROPOSED LOW
FOUNDATION WALL w/2x6 STUD WALL ATOP
PROPOSED SQUARE FOOTAGE NOTE:
FIRST FLOOR LIVING AREA = 1,137 ft²SECOND FLOOR LIVING AREA = 920 FT²ATTIC FLOOR LIVING AREA = 432 FT²
TOTAL LIVING AREA: = 2,489 FT²
FLOOR PLAN LEGEND:
WALL TO BE DEMOLISHED
EXISTING STUD WALL
PROPOSED STUD WALL
OBJECT ABOVE
OBJECT BELOW
DENOTES FOUNDATION WALL
TO BE DEMOLISHED
DENOTES EXISTING
FOUNDATION WALL
A
S2DENOTES ARCHITECTURAL BUILDING SECTION
(WINDOWS SHOWN FOR ESTIMATING AND PERMITTING ONLYFINAL ORDER TO BE VERIFIED AND APPROVED BY OWNER)
DRAWING INDEX:
A0 COVER PAGE
A1 NOTES and LEGENDS
A2 PROPOSED REAR ELEVATION
A2.2 PROPOSED RIGHT SIDE ELEVATION
A2.3 PROPOSED LEFT SIDE ELEVATION
A3 PROPOSED FIRST FLOOR PLAN
A3.1 EXISTING FIRST FLOOR PLAN
A4 PROPOSED SECOND FLOOR PLAN
A4.1 EXISTING SECOND FLOOR PLAN
A5 PROPOSED ATTIC FLOOR PLAN
A5.1 EXISTING ATTIC FLOOR PLAN
A6 PROPOSED ROOF PLAN
A6.1 EXISTING ROOF PLAN
A7 PROPOSED BUILDING SECTION "A-A"
a8 proposed building section "B-B"
A9 CUPOLA DETAIL
A10 SHEAR WALL DETAILS
S1 PROPOSED FOUNDATION PLAN
S1.1 EXISTING FOUNDATION PLAN
S2
S3
S4
S5
FOUNDATION & CONCRETE NOTES:
1. SPREAD FOOTINGS SHALL BEAR LEVEL ON UNDISTURBED SOIL HAVING AN ALLOWABLE BEARING CAPACITY OF
TWO TONS PER SQUARE FOOT.
2. IF BEARING MATERIALS WITH A LOWER BEARING CAPACITY THAN TWO TONS PER SQUARE FOOT ARE
ENCOUNTERED AT THE SPECIFIED ELEVATIONS, THE UNDERLYING UNSUITABLE MATERIAL SHALL BE REMOVED
AND REPLACED WITH SUITABLE MATERIAL TO BE APPROVED BY THE ENGINEER/ARCHITECT.
3. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE VALIDITY OF SUBSURFACE CONDITIONS.
4. NO FOUNDATION SHALL BE PLACED IN WATER OR ON FROZEN GROUND.
5. FOOTINGS SHALL BE PROTECTED AGAINST FROST UNTIL PROJECT IS COMPLETED.
6. BACKFILL UNDER ANT PORTION OF THE FOOTINGS AND SLABS SHALL BE COMPACTED IN 6" LIFTS OF 95%
COMPACTED GRAVEL AS APPROVED BY THE ENGINEER.
7. CONCRETE WORK SHALL CONFORM TO THE LATEST AMERICAN CONCRETE INSTITUTE CODE FOR "BUILDING
CODE REQUIREMENTS FOR REINFORCED CONCRETE" AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS".
8. CONCRETE FOUNDATION WALLS AND FOOTINGS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000
P.S.I. AT 28 DAYS AND 3,500 P.S.I. FOR SLABS, WITH A SLUMP OF NO MORE THEN 4" AND AIR
ENTRAINMENT OF 4-6%. THE USE OF CALCIUM CHLORIDE IS NOT PERMITTED. PROVIDE PROPER CONCRETE
PROTECTION FOR HEAT IN COLD WEATHER AND MAINTAIN PROPER CURING PROCEDURES IN ACCORDANCE
WITH THE A.C.I.
9. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T.M. 615, GRADE 60.
10. ALL CONCRETE SLABS ON THE GROUND SHALL BE REINFORCED WITH 6x6-10/10 (MIN.) WELDED WIRE
FABRIC PLACED AT MID-DEPTH, OR AS OTHERWISE SHOWN ON THE DRAWINGS WELDED WIRE FABRIC
REINFORCEMENT SHALL CONFORM TO A.S.T.M. A185, AND SHALL LAP 6" MINIMUM OR ONE SPACE, WHICHEVER
IS LARGER, AND SHALL BE WIRED TOGETHER. PROVIDE SUFFICIENT CHAIR OR SUPPORT BARS AS NECESSARY
TO POSITION WELDED WIRE FABRIC.
11. WHERE CONTINUOUS BARS ARE CALLED FOR THEY SHALL BE RUN CONTINUOUSLY AROUND CORNERS AND
LAPPED AT NECESSARY SPLICES OR HOOKED AT DISCONTINUOUS ENDS. LAPS SHALL BE 40 BAR DIAMETERS,
UNLESS OTHERWISE SHOWN.
12. NOTIFY BUILDING DEPARTMENT FOR INSPECTION OF COMPLETED INSTALLATION OF REINFORCEMENT AT LEAST
24 HOURS PRIOR TO SCHEDULED PLACEMENT OF CONCRETE.
13. PLACEMENT OF CONCRETE POURS FOR FOUNDATION WALLS SHOULD HAVE A VERTICAL 2"x4" KEY WITH
CONTINUOUS REINFORCING (40 BAR DIAMETER MINIMUM) THRU THE CONSTRUCTION JOINT.
14. ALL REINFORCING BARS SHALL BE COLD BENT IN ACCORDANCE TO THE PROPER RADII ESTABLISHED BY
THE AMERICAN CONCRETE INSTITUTE. UNDER NO CONDITIONS SHALL HEAT BE APPLIED TO THE BARS TO
OBTAIN BENDS.
15. THE USE OF CONTROL JOINTS IN THE SLAB IS RECOMMENDED TO CONTROL CRACKING. SAW CUT TO A
DEPTH ONE HALF INCH NOT-TO-EXCEED 10 FEET BY 10 FEET.
16. DAMP PROOF ALL FOUNDATION WALLS BELOW GRADE, OTHER THAN FROST WALLS.
GENERAL NOTES:
1. GENERAL CONTRACTOR TO CONFORM TO ALL LOCAL AND STATE BUILDING CODE REQUIREMENTS.
2. GENERAL CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS AND NOTIFY
THE ENGINEER OF ANY DISCREPANCIES.
3. THE ENGINEER IS RESPONSIBLE ONLY FOR INFORMATION SHOWN ON THE CERTIFIED ENGINEER'S DRAWINGS.
THE DESIGN AND LAYOUT OF ALL OTHER INFORMATION IS THE RESPONSIBILITY OF OTHERS AND MUST
CONFORM TO THE MASSACHUSETTS BUILDING CODE REQUIREMENTS. REFER TO STRUCTURAL ENGINEERING BY
OTHERS FOR CERTIFIED BEAM CALCULATIONS AND CERTIFIED WIND DESIGN DETAILS.
4. ALL HEATING, PIPING, INSULATION, ELECTRICAL, FIREPROOFING AND OTHER REQUIREMENTS ARE THE
RESPONSIBILITIES OF OTHERS.
5. NOTIFY THE ENGINEER OF ANY ARCHITECTURAL MODIFICATIONS OR DIMENSION CHANGES THAT MAY AFFECT
THE STRUCTURAL DESIGN.
STRUCTURAL STEEL NOTES:
1. ALL STEEL BEAMS SHALL BE NEW STEEL CONFORMING TO THE A.I.S.C. SPECIFICATIONS FOR DESIGN
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS AND A.S.T.M. - GRADE 50. ALL CAP AND
BASE PLATES AND OTHER MISCELLANEOUS STEEL MAY BE A.S.T.M. GRADE A36.
2. ALL SCHEDULE 40 PIPE SHALL BE NEW STEEL CONFORMING TO THE A.I.S.C. SPECIFICATIONS FOR DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS AND A.S.T.M. SPECIFICATION A53, TYPE
"E" OR "S", GRADE "B", WITH A MINIMUM YIELD STRESS OF 35 K.S.I..
3. ALL SHOP AND FIELD WELDS SHOWN SHALL BE MADE BY APPROVED CERTIFIED WELDERS AND SHALL
CONFORM TO THE A.W.S. CODE FOR BUILDINGS. ALL WELDS SHALL DEVELOP THE FULL STRENGTH OF THE
MATERIAL BEING WELDED. USE EXX 70 ELECTRODES.
4. NO PERMANENT CONNECTIONS SHOULD BE MADE UP UNTIL THE STRUCTURE HAS BEEN PROPERLY ALIGNED.
PROVIDE TEMPORARY BRACING AS REQUIRED.
5. STEEL FABRICATOR IS RESPONSIBLE FOR FINAL LENGTHS, CONNECTION DETAILS AND DESIGN IN
ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF THE LATEST EDITION OF THE A.I.S.C. DETAILING MANUAL.
SUBMIT SHOP DRAWINGS WITH ALL DETAILS TO THE GENERAL CONTRACTOR PRIOR TO FABRICATION.
6. USE 1/2" MINIMUM CAP PLATE AND BASE PLATES (6X6 MINIMUM) FULLY WELDED ALL AROUND AT COLUMNS WITH
3/16" FILLET WELD, OR AS OTHERWISE SPECIFIED ON THE DRAWINGS. ALL STEEL COLUMN EXTERIOR BASE PLATE
SHALL BE BOLTED TO THE CONCRETE FOUNDATIONS WITH 4-5/8" DIAMETER ANCHOR BOLTS.
7. ALL STEEL SHALL HAVE TWO COATS OF RUST-INHIBITOR PRIMER PAINT. TOUCH UP ALL WELDS, SCRATCHES
OR SCRAPES IN PAINT AFTER ERECTION.
8. STEEL BEAM MAY BE SPLICED AT STEEL COLUMN CAP PLATE WITH A MAXIMUM GAP BETWEEN BEAMS OF
1/4". USE 1/4" TIE PLATE WELDED TO WEBS.
9. FRAME JOISTS TO TOP OF BEAM ON A 2x8 TOP NAILER THRU-BOLTED WITH 1/2" DIAMETER BOLTS
STAGGERED AT 24" O.C.. JOISTS TO BE ANCHORED TO THE TOP NAILER WITH SIPMSON H4 HURRICANE CLIPS.
FLUSH FRAME JOISTS TO THE FULL DEPTH WEB BLOCKING FASTENED TO THE BEAM WITH 1/2" DIAMETER
THRU-BOLTS AT 24" O.C. STAGGERED TOP AND BOTTOM.
POST UP:
SEE FRAMING PLAN
OF FLOOR ABOVE
FOR TYPE AND SIZE
LAMINATED POST
DOUGLAS FIR
POST SIZE
4x4 D
F POST
POST UP
LAM
JACK STUDS
KING STUDS
2 JS
2 KS
METAL HANGERS
STEEL BEAM
LVL BEAM
BEARING WALL
BEARING WALL ABOVE
FRAMING BELOW
EXISTING FRAMING
PROPOSED FRAMING
SMOKE DETECTOR
SMOKE/CO2
HEAT SMOKE
S
S/
CO
H/S
FRAMING NOTES:
1. ALL FRAMING LUMBER SHALL BE S.P.F. (SPRUCE-PINE-FIR) GRADE N1/N2 OR APPROVED EQUAL (UNLESS
OTHERWISE SPECIFIED) AND SHALL MEET THE REQUIREMENTS OF THE AMERICAN FOREST AND PAPER
ASSOCIATION. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 875 P.S.I. THE MINIMUM ALLOWABLE
COMPRESSION STRESS (Fc) SHALL BE 425 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF ELASTICITY (E) SHALL
BE 1,400,000 P.S.I. OTHER FRAMING MATERIAL FOR INTERIOR NON-LOAD BEARING STUDS MAY BE SUBSTITUTED
ONLY UPON APPROVAL OF THE ENGINEER.
2. ALL PRESSURE TREATED (CCA TREATED) DIMENSIONAL FRAMING LUMBER SHALL BE SOUTHERN YELLOW PINE
GRADE NO. 2.. THE MINIMUM ALLOWABLE BENDING STRESS (Fb) SHALL BE 1,050 P.S.I. THE MINIMUM
ALLOWABLE COMPRESSION STRESS (Fc) SHALL BE 565 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF
ELASTICITY (E) SHALL BE 1,600,000 P.S.I.
3. ALL LVLs TO BE MANUFACTURED BY TRUS JOIST, GEORGIA PACIFIC OR APPROVED EQUAL. THE MINIMUM
ALLOWABLE BENDING STRESS (Fb) SHALL BE 2,900 P.S.I. THE MINIMUM ALLOWABLE COMPRESSION STRESS
(Fc) PERPENDICULAR TO THE GRAIN SHALL BE 750 P.S.I. THE MINIMUM ALLOWABLE MODULUS OF
ELASTICITY (E) SHALL BE 2,000,000 P.S.I. ALL PARALAMS EXPOSED TO THE WEATHER SHALL BE PRESSURE
TREATED (CCA TREATED). INSTALL MICROLAMS AND PARALAMS IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. PARALLAM (LAM) POSTS SHALL HAVE AN ALLOWABLE COMPRESSION STRESS 2900 PSI AND A
MODULUS OF ELASTICITY OF 2,000,000 P.S.I.
4. USE 3/4" TONGUE AND GROVE STRUCTURAL GRADE FIT PLYWOOD FLOOR SHEATHING, 5/8" EXTERIOR
STRUCTURAL GRADE FIR (C.D.X.) PLYWOOD ROOF SHEATHING AND 1/2" EXTERIOR STRUCTURAL GRADE FIR
(C.D.X.) AT WALLS. ALL JOINTS SHALL BE BLOCKED WITH LIMBER OR OTHER APPROVED SUPPORTS.
5. ALL EXTERIOR AND INTERIOR STUD WALLS TO BE 2x4 MINIMUM @ 16" O.C. UNLESS NOTED OTHERWISE.
6. PROVIDE ADEQUATE WALL RESISTANCE TO RAKING BY DIAGONAL CORNER WIND BRACING ANCHORED TO SILL
PLATES.
7. PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS AND/OR DOUBLE ALL JOISTS UNDER EACH PARTITION.
8. USE FULLY NAILED METAL CONNECTORS (TECO, SIMPSON OR EQUAL), JOIST OR BEAM HANGERS WHEN
JOISTS OR BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL
POSTS.
9. FOR NONBEARING ROUGH WINDOW OPENINGS AND INTERIOR DOOR OPENINGS UP TO 3 FEET, USE 2-2x6
HEADER BEAMS. FROM 3 FEET TO 5 FEET, USE 2-2x8 HEADER BEAMS AND FROM 5 FEET TO 7 FEET, USE 2-2x10
HEADER BEAMS AND USE LVLs FOR SPANS EXCEEDING 7 FEET, EXCEPT AS NOTED OTHERWISE ON THE
PLANS OR SPECIFICATIONS. USE TRIPLES FOR 2x6 WALLS. IF LVLs ARE SPECIFIED ON THE PLANS,
PROVIDE DOUBLE JACK STUD SUPPORTS OR AS OTHERWISE SPECIFIED ON THE PLAN.
10. ALL FRAMING TO BE INSTALLED IN ACCORDANCE WITH THE MASSACHUSETTS BUILDING CODE REQUIREMENTS
AND GENERAL FRAMING PRACTICE AS DETAILED IN THE "ARCHITECTURAL GRAPHICS STANDARDS", BY RAMSEY
& SLEEPER.
11. ALL PLYWOOD FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING WOOD FRAMING MEMBERS USING
AMERICAN PLYWOOD ASSOCIATION (A.P.A.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC. PL400
SUBFLOOR CONSTRUCTION ADHESIVE, OR APPROVED EQUAL.
12. ALL WALL STUDS TO ALIGN WITH FLOOR JOISTS AND ROOF RAFTERS.
13. THE CROSS WALLS AND TIE BEAMS ARE TO PROVIDE THE LATERAL RESTRAINT FOR THE BUILDINGS AND
SHOULD BE SECURELY ATTACHED AT EACH END AND/OR TO THE EXTERIOR WALLS.
14. BUILT-UP BEAMS (3 PIECES MAXIMUM) USING CONVENTIONAL FRAMING LUMBER SHALL BR FULLY SPIKED
TOGETHER WITH 2-10D NAILS AT 8" O.C. AND LVLs WITH 2-16D NAILS (TOP AND BOTTOM) AT 8" O.C., OR AS
OTHERWISE NOTED ON THE DRAWINGS, OR AS RECOMMENDED BY THE MANUFACTURER.
15. ALL NAILS, FASTENERS AND CONCRETE EXPOSED TO THE WEATHER SHALL BE HOT-DIP GALVANIZED
16. ALL LUMBER THAT COMES IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
OF
A1
NOTES A
ND
LEG
END
S
A10
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
GRADE
GRADE
TW 2442TW 2442
TW 24310TW 24310
24'-0" new 5'-6" existing
PROPOSED REAR ELEVATIONSCALE: 3/8"=1'-0"
TW 24310
A2
PR
OP
OSED
REAR
ELEVATIO
N
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
GRADE
GRADE
EXISTING
TW 2442TW 2442
TW 2432
TW 2442
TW 24310
EXISTING
EXISTING
9'-10" EXISTING 12'-4" EXISTING9'-4" NEW 18'-0" new
PROPOSED RIGHT SIDE ELEVATIONSCALE: 3/8"=1'-0"
1210
5'-0" NEW
A2.1
PR
OP
OSED
RIG
HT S
IDE E
LEVATIO
N
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
GRADEGRADE
EXISTINGTW 24310
13'-0" NEW 28'-6" EXISTING18'-0" new
PROPOSED LEFT SIDE ELEVATIONSCALE: 3/8"=1'-0"
12
10
TW 2442TW 2442TW 2442
TW 24310 TW 24310 TW 24310 TW 24310
C23
TW 2442 TW 2442
A2.2
PR
OP
OSED
LEFT S
IDE E
LEVATIO
N
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
FWG 6068
36" REF.
3'-0
"X6'-8"
D.W.
2'-4"x
6'-8
"
2'-0
"x6'-8"
up
13r
DINING ROOM(17'-4"x10'-6")
living ROOM(11'-6"x12'-6")
foyer(5'-6"x12'-6")
covered porch
KITCHEN(13'-10"x12'-8")
closet
9'-10" EXISTING 12'-4" EXISTING
12'-6" EXISTING24'-0" EXISTING
18'-0
" EXIS
TIN
G8'-0
" NEW
proposed FIRST FLOOR PLANSCALE: 3/8"=1'-0"
HALF
WALL
2'-8
"x6'-8"
9'-4" NEW
2'-8"x
6'-8
"
closet
COAT
HOOKS
GAS L
OG
w/ tv a
bove
bench o
r b
uilt-in
sb
ench o
r b
uilt-in
s
6'-6"
c.o
.
5'-8"
c.o
.
2'-8" c.o.
2'-6"
c.o
.
mudroom(7'-6"x8'-4")
LAND
ING
(4'-6"x
5'-0
")
land
ing
(4'-6"x
3'-4")
family room(19'-0"x17'-0")
up 15 RISERS
USE 914" TREADS
6'-6"
c.o
.
5'-0" island
2'-6"X
6'-8
"
dn
13r
3'-0" c.o.
18'-0" new
24'-0
" new
18'-0" new
new
railing
S/
CO S/
CO
S/
CO
2'-6"
NEW
DOG PEN(4'-6"X9'-0")
3'-10
"12'-4"
7'-10
"
3'-0"12'-0"3'-0"4'-8" 4'-8"
9'-0" 9'-0"
2'-4"
2'-2"
A
A7
B
A8
B
A8
2'-4"x
6'-8
"
5'-0" NEW
3'-6"
NEW
4'-6"
NEW
7'-0
" NEW
7'-0
" EXIS
TIN
G
5'-10"6'-8"
A3
PR
OP
OSED
fir
st f
loor
plan
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
FWG 6068
36" REF.
3'-0
"X6'-8"
2'-8
"x6'-8"
D.W.
2'-4"x
6'-8
"
2'-0
"x6'-8"
working island
up
13r
DINING ROOM(17'-4"x10'-6")
living ROOM(11'-6"x12'-6")
foyer(5'-6"x12'-6")
covered porch
KITCHEN(13'-10"x12'-8")
pantry(9'-4"x6'-2")
deck(8'-0"x8'-0")
closet
23'-8" EXISTING 13'-4" EXISTING 6'-6" EXISTING
10'-0
" EXIS
TIN
G2'-0
" (E
)2'-6"
(E)
6'-6" EXISTING13'-0" EXISTING24'-0" EXISTING
18'-0
" EXIS
TIN
G3'-6"
(E)
7'-0
" EXIS
TIN
G
EXISTING FIRST FLOOR PLANSCALE: 3/8"=1'-0"
(AREA: 687 FT²)
HALF
WALL
3'-4"
c.o
.
5'-8"
c.o
.
2'-8" c.o.
2'-6"
c.o
.
2'-8"
c.o
.
A3.1
EXIS
TIN
G f
irst f
loor
plan
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
12'-6" EXISTING8'-8" EXISTING
dn 15 RISERS
USE 914" TREADS
18'-0" new
up
13r
3'-0" (E)
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
proposed SECOND FLOOR PLANSCALE: 3/8"=1'-0"
12'-4" EXISTING
SHOWER(4'-2"x3'-0")
2'-6
"X6'-8"
2'-6
"X6'-8"
2'-0
"x6'-8"
30" VAN.
(2) 2'-0
"x6'-8"
BEDROOM #4(8'-6"x10'-2")
BEDROOM #3(8'-6"x11'-6")BEDROOM #2
(11'-6"x11'-6")
HOUSE BATH(4'-2"x11'-8")
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
SLOP
E
SLOP
E
CLOSET
SOAKING TUB(3'-0"x5'-6")
3'-0" c.o.
60
" VANITY
SHOWER(3'-0"x6'-0")
bench
KIN
G
2'-4"x6'-8"
(POCKET)
2'-4"x
6'-8"
(POCK
ET)
LONG
DR
ESSER
master BEDROOM(14'-4"x10'-8")
master w.i.c.(4'-4"x9'-6")
master
bath(14'-4"x6'-0")
SLOP
E
24'-0
" new
18'-0" new12'-6" EXISTING
S
S
S
S
S/
CO
S/
CO
24'-0
" NEW
2'-6"
10'-4"
4'-6"
3'-0"15'-0"
3'-6" 8'-10" 5'-8"
A
A7
B
A8
B
A8
SLOP
E
SLOP
E
2'-6"x6'-8"
(POCKET)
2'-8
"x6'-8"
W/D
stack
linen
6'-8"
A4
PR
OP
OSED
SECOND
FLOOR
PLAN
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
up
13r
3'-0" (E) 8'-8" EXISTING
4'-6"
(E)
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
18'-0
" EXIS
TIN
G
EXISTING SECOND FLOOR PLANSCALE: 3/8"=1'-0"
(AREA: 488 FT²)
12'-4" EXISTING
SHOWER(4'-2"x3'-0")
2'-6
"X6'-8"
2'-6
"X6'-8"
2'-0
"x6'-8"
30" VAN.
(2) 2'-0
"x6'-8"
BEDROOM #3(8'-6"x10'-2")
BEDROOM #2(8'-6"x11'-6")BEDROOM #1
(11'-6"x11'-6")
HOUSE BATH(4'-2"x11'-8")
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOPE
CLOSET
A4.1
EXIS
TIN
G S
ECOND
FLOOR
plan
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
DN
13r
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
proposed ATTIC FLOOR PLANSCALE: 3/8"=1'-0"
24'-0" EXISTING
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
2'-6
"X6'-8"
2'-6"X
6'-8
"
2'-6"X
6'-8
"
2'-4"x
6'-8"
CLOSETCLOSET
SLOP
E
SLOPE SLOPE
SLOP
E
S
S
S
S/
CO
12'-6" EXISTING 18'-0" newSLOP
E
24'-0
" new
SLOP
E
A
A7
B
A8
C
A8
B
A8
C
A8
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
18'-0" new
24'-0
" NEW
SLOP
E
SLOP
E
12'-6" EXISTING
A5
PR
OP
OSED
ATTIC
FLOOR
PLAN
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
DN
13r
3'-0" (E) 8'-8" EXISTING
4'-6"
(E)
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
18'-0
" EXIS
TIN
G
EXISTING ATTIC FLOOR PLANSCALE: 3/8"=1'-0"
(AREA: 432 FT²)
12'-4" EXISTING
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOPE
2'-6
"X6'-8"
2'-6"X
6'-8
"
2'-6"X
6'-8
"2'-4"x
6'-8"
CLOSETCLOSET
SLOP
E
SLOPE SLOPE
A5.1
EXIS
TIN
G A
TTIC
FLOOR
PLAN
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
3'-0" (E)
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
proposed ROOF PLANSCALE: 3/8"=1'-0"
11'-10" EXISTING
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
SLOP
E
SLOPE SLOPE
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOP
E
9'-4" EXISTING 12'-4" EXISTING 18'-0" newSLOP
E
24'-0
" new
18'-0" new12'-6" EXISTING
SLOP
E
2'-6"
NEW
A
A7
B
A8
C
A8
B
A8
C
A8
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
A6
PR
OP
OSED
ROOF P
LAN
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
3'-0" (E) 8'-8" EXISTING
4'-6"
(E)
24'-0" EXISTING
18'-0
" EXIS
TIN
G4'-6"
(E)
18'-0
" EXIS
TIN
G
EXISTING ROOF PLANSCALE: 3/8"=1'-0"
12'-4" EXISTING
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOPE
SLOPE
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOPE
SLOP
E
SLOPE SLOPE
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOP
E
SLOP
E
A6.1
EXIS
TIN
G R
OOF P
LAN
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
DAMP PROOF FOUNDATION
WALL BELOW GRADE
4" CONCRETE SLAB
10" CONCRETE
FOUNDATION WALL
PROPOSED BUILDING SECTION "A-A"SCALE: 3/8"=1'-0"
8'-11 2"
7'-5
3 4"
2ND FLOOR
B.O. JOIST
T.O. RIDGE
7'-9"
b.o. joist
t.o. slab
18'-0" NEW
continuous 2x12
ridge board
12
10
ASPHALT SHINGLES ON
15# FELT ON
5/8" CDX PLYWOOD
2-#4
T&B
(TYP.)
5/8" A.B.
@ 4'-0" O.C.
(TYP.)
1178" TJI
2x8 CEILING JOISTS
8'-4
1 2"
T.O. JOIST
B.O. JOIST
R-21
INSULATION
R-49 INSULATION
R-30 INSULATION
h2.5a (simpson)
(BOTH ENDS) typ.
4-16d FACE NAILS (TYP.)
(BOTH SIDES)
8'-4
1 2"+
/- M
ATCH
EXIS
TIN
G W
ALL H
T.
1178" TJI
GRADE
1st floor
GRADE
backfilling to be done after
1st floor joists and sheathing
were installed (typ.)
LINE
OF 78
" CLE
AR
LINE
OF 78
" CLE
AR
4'-0
" M
IN.
BELOW G
RAD
E
LINE OF STAIRS
14 RISERS @ 758"
13 TREADS @ 914"
LINE OF STAIRS
15 RISERS @ 738"
14 TREADS @ 914"
2x8 CEILING JOISTS2x
10 R
AFTER
S
6-16d FACE NAILS (TYP.)
(BOTH SIDES)
MASTER BEDROOM
AND BATHROOM CEILING
12'-0
" M
AX H
EIG
HT
2x10
RAFT
ERS
A7
PR
OP
OSED
BUILD
ING
SECTIO
N "
A-A"
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
PROPOSED BUILDING SECTION "B-B"SCALE: 3/8"=1'-0"
8'-11 2"
2ND FLOOR
B.O. JOIST
T.O. RIDGE
6'-5"
b.o. joist
t.o. slab
1'-11
1 2"
1st floor
2'-6"
5'-0
"
DAMP PROOF FOUNDATION
WALL BELOW GRADE
2X8 FLOOR JOISTS
GRADE
5/8" A.B.
@ 4'-0" O.C.
(TYP.)
2-#4
T&B
(TYP.)
4'-0
" M
IN.
BELOW G
RAD
E
2x8 CEILING JOISTS
2x10 RAFTERS
R-49 INSULATION
h2.5a (simpson)
typ.
R-21
INSULATION
R-30
INSULATION
(E) FLOOR JOISTS
(E) FLOOR JOISTS
(E) FLOOR JOISTS
EXISTIN
G R
AFTE
RS
6'-8"
R.O
.CRAWL SPACE
(7'-2"x13'-0")
mudroom(7'-6"x8'-4")
DINING ROOM(17'-4"x10'-6")
BEDROOM #4(8'-6"x10'-2")
8'-0" NEWEXISTING
4" CONCR. SLAB
123.5+/-
ASPHALT SHINGLES ON
15# FELT ON
5/8" CDX PLYWOOD
A8
PR
OP
OSED
BUILD
ING
SECTIO
N "
B-B
"
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
A10
SHEAR
WALL D
ETAILS
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
OFA10
covered porch
18'-0
" EXIS
TIN
G
PROPOSED FOUNDATION PLANSCALE: 3/8"=1'-0"
ACCESS
DOUBLE HUNGDOUBLE HUNG
DOUBLE HUNG
2'-8"x
6'-8
"
FURNACE
NEW LALLY COLUMN
WITH 24"X24"X12" DEEP FTG.
ELECTRIC PANEL
NEW LALLY COLUMN
WITH 24"X24"X12" DEEP FTG. NEW LALLY COLUMN
WITH 24"X24"X12" DEEP FTG.
up 14 RISERS
USE 914" TREADS
2'-8
"x6'-8"
DOUBLE HUNG
DOUB
LE H
UNG
NEW 10" SONO TUBE
4' MIN. BELOW GRADE
(TYP.)
9'-10" EXISTING 12'-4" EXISTING
12'-6" existing24'-0" EXISTING
8'-0
" NEW
9'-4" NEW 18'-0" new
24'-0
" new
18'-0" new
NEW FULL BASEMENT(22'-4"x16'-4")
4" CONCRETE SLAB
STEP FOOTING AS
REQUIRED TO BEAR ON
UNDISTURBED SOIL
#5 @ 12" O.C. 2'-6" LONG, EPOXY
GROUTED IN PRE-DRILLED HOLES
6" MIN. EMBEDMENT (TYP.)
12"DX24"W CONCRETE
FOOTINGS SEE SECTIONS
10" CONCRETE FOUNDATION
WALLS TO 4'-0" BELOW
GRADE MINIMUM
CRAWL SPACE(7'-2"x13'-0")
10" CONC.
FND. WALL
S/
CO
2'-6"
NEW
BLOCK-OUT
EXISTING WINDOW
3'-10
"12'-4"
7'-10
" A
A7
B
A8
B
A8
5'-0" NEW
3'-6"
NEW
4'-6"
NEW
7'-0
" NEW
4'-6"
new
18'-0
" EXIS
TIN
G
7'-0
" EXIS
TIN
G
DOUBLE HUNG
9'-0" 9'-0"
OF
S1
PR
OP
OSED
FOUND
ATIO
N P
LAN
S5
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION
covered porch
23'-8" EXISTING 13'-4" EXISTING 6'-6" EXISTING
10'-0
" EXIS
TIN
G2'-0
" (E
)2'-6"
(E)
6'-6" EXISTING13'-0" EXISTING24'-0" EXISTING
18'-0
" EXIS
TIN
G3'-6"
(E)
7'-0
" EXIS
TIN
G
EXISTING FOUNDATION PLANSCALE: 3/8"=1'-0"
(AREA: 577 FT²)
DOUBLE HUNG DOUBLE HUNG
DOUBLE HUNGDOUBLE HUNG
DOUBLE HUNG
2'-8"x
6'-8
"
2'-8
"x6'-8"
DOUB
LE H
UNG
FURNACE
TEMP LALLY COLUMN
TEMP LALLY COLUMN
TEMP LALLY COLUMN
ELECTRIC PANEL
S1.1
EXIS
TIN
G F
OUND
ATIO
N p
lan
OFS5
PR
OJECT:
CHECKED BY:
DRAWN BY:
DATE:
SCALE:
DESCR
IPTIO
ND
ATE
REVIS
ION
TITLE:
CCOPYRIGHT 2021 BY BAKER ARCHITECTURAL DESIGN THE ARCHITECTURAL PLANS, DRAWINGS, DESIGNS, SPECIFICATIONS AND OTHER ARRANGEMENTS ON THIS SHEET ARE AND SHALL REMAIN THE PROPERTY OF BAKER ARCHITECTURAL DESIGN. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT, OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED, WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN CONSENT OF BAKER ARCHITECTURAL DESIGN.
PROGRESS PRINT: NOT FOR CONSTRUCTION
PR
OG
RESS P
RIN
T: NOT F
OR
CONSTR
UCTIO
N
HULL M
A, 0
20
45
34 V
ALLEY B
EACH A
VENUE
LAR
RY C
OR
COR
AN &
LYND
A F
ER
RENTIN
O
PB
4/30/2021
AS NOTED
ZB
A S
ET -
4/3
0/2
021
SEE SHEET A1 FOR DRAWING INDEX
IF PRINTED ON 11x17, ALL SCALE IS HALF.
CONTRACTOR TO VERIFY ALL DIMENSIONS
AND SETBACKS PRIOR TO CONSTRUCTION