Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 1 of 40
EMC - TEST REPORT
Report Number : 68.720.15.005.01 Date of Issue: Oct 22, 2015
Model : DHP380, DHP380A
Product Type : 2.4GHz Digital Headphone
Applicant : Uni-Art Precise Electronics (Shenzhen) Ltd.
Address : Building 1,2&3, No. 50 Xinsha Road, Shajing Town, Baoan District
518125 Shenzhen City, Guangdong Province, PEOPLE'S REPUBLIC
OF CHINA
Production Facility : Uni-Art Precise Electronics (Shenzhen) Ltd.
Address : Building 1,2&3, No. 50 Xinsha Road, Shajing Town, Baoan District
518125 Shenzhen City, Guangdong Province, PEOPLE'S REPUBLIC
OF CHINA
Test Result : Positive Negative Total pages including Appendices
:
40
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles
outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports.
This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval.
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 2 of 40
Table of Content
1 Report Version .............................................................................................................. 3
2 General Information....................................................................................................... 4 2.1 Notes ............................................................................................................................. 4 2.2 Testing Laboratory ........................................................................................................ 5 2.3 Details of Applicant........................................................................................................ 5 2.4 Application Details ......................................................................................................... 5 2.5 Applied Standard ........................................................................................................... 5 2.6 Test Summary ............................................................................................................... 6 2.7 Performance Criteria ..................................................................................................... 7
3 EUT Information ............................................................................................................ 8 3.1 EUT Description ............................................................................................................ 8 3.2 EUT Appearance ........................................................................................................... 8
4 System Configuration during EMC Test ........................................................................ 9 4.1 Test Configurations ....................................................................................................... 9 4.2 Test Mode ..................................................................................................................... 9 4.3 Configurations of Test System ...................................................................................... 9 4.4 Associated Equipment Used during Test .................................................................... 10
5 Electromagnetic Interference (EMI) ............................................................................. 11 5.1 Radiated Disturbance 30MHz to 6000MHz ................................................................. 11 5.2 Conducted Disturbance 0.15 MHz to 30MHz On AC Port ........................................... 13 5.3 Current Harmonics Emissions ..................................................................................... 14 5.4 Voltage Fluctuations (Flicker) ...................................................................................... 15
6 Electromagnetic Susceptibility (EMS).......................................................................... 16 6.1 Immunity to Electrostatic Discharge ............................................................................ 16 6.2 Immunity to Radiated Electric Fields 80MHz to 2700MHz ........................................... 18 6.3 Immunity to Electrical Fast Transient Bursts ............................................................... 19 6.4 Immunity to Surges ..................................................................................................... 20 6.5 Immunity to Continuous Conducted Interference 0.15MHz to 80MHz ......................... 21 6.6 Immunity to Voltage Dips and Short Interruption of AC Power Port ............................ 22
7 Main Test Instruments ................................................................................................. 23
8 System Measurement Uncertainty .............................................................................. 25
9 Graph and Data of Emission Test ............................................................................... 26 9.1 Radiated Disturbance .................................................................................................. 26 9.2 Conducted Disturbance ............................................................................................... 30 9.3 Current Harmonics Emissions ..................................................................................... 34 9.4 Voltage Fluctuation and Flicker ................................................................................... 35
10 Setup Photographs of EUT ......................................................................................... 36
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 3 of 40
1 Report Version
Revision Release Date History/Memo.
1.0 Oct 21, 2015 Initial Release
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 4 of 40
2 General Information
2.1 Notes
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025.
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports.
This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. Prepared By 2015-10-21 Calvin Weng EMC Project Engineer Date Name Signature
Approved by 2015-10-21 Cookies Bu EMC Project Manager Date Name Signature
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 5 of 40
2.2 Testing Laboratory
Test Laboratory:
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Address: Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China, Phone: +86-755-8828 6998 Fax: +86-755-8828 5299
2.3 Details of Applicant
CLIENT: 2.4GHz Digital Headphone Address: Building 1,2&3, No. 50 Xinsha Road, Shajing Town, Baoan District 518125 Shenzhen City, Guangdong Province, PEOPLE'S REPUBLIC OF CHINA Product Description: 2.4GHz Digital Headphone Manufacturers Model No.: DHP380, DHP380A
2.4 Application Details Date of receipt of order: Jan 12, 2015 Date of receipt of test item: Jan 13, 2015 Date of test: Jan 13, 2015–Oct 21, 2015
2.5 Applied Standard
EN 301 489-1 V 1.9.2(2011-09) EN 301 489-17 V2.2.1(2012-09)
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 6 of 40
2.6 Test Summary
Test Items Test Mode
Performance Class & Required Performance
Criteria Result
Radiated Emissions
Enclosure Port
TM1
TM2 CLASS B Pass
Conducted Emissions
DC Power Port AC Power Port Telecommunication
Ports
TM1
TM2 CLASS B Pass
Current harmonics emissions
AC Power Port
TM1
TM2 CLASS A Pass
Voltage fluctuations and flickers
AC Power Port
TM1
TM2 NA Pass
Immunity To Radiated Electromagnetic Fields
Enclosure Port
TM1
TM2 CT/CR Pass
Immunity To Electrostatic Discharge
Enclosure Port
TM1
TM2 TT/TR Pass
Immunity To Electrical Fast Transient Bursts AC Power Port DC Power Port Telecommunication
Ports
TM1
TM2 TT/TR Pass
Immunity To Surges AC Power Port DC Power Port Telecommunication
Ports
TM1
TM2 TT/TR Pass
Immunity To Continuous Conducted Interference
AC Power Port
DC Power Port
Telecommunication Ports
TM1
TM2 CT/CR Pass
Immunity To Voltage dips and Short Interruption
AC Power Port
TM1
TM2 TT/TR Pass
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 7 of 40
2.7 Performance Criteria
Clause 6 of EN301 489-1
Criteria Performance Criteria
CT/CR
During and after the test, the apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the apparatus is used as intended.
TT/TR
After the test, the apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer, when the apparatus is used as intended.
Remark: The EUT has met the requirements of Performance Criterion defined were in accordance with
Product standards.
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 8 of 40
3 EUT Information
3.1 EUT Description DHP380 is identical with DHP380A, the only difference lies in the colour, therefore, full test was applied on DHP380, another model deem to fulfil the EMC requirement without further testing.
EUT Description
Product Name 2.4GHz Digital Headphone
Model Number DHP380
TX Frequency
Sequence 1: 2406MHz-2472MHz Sequence 2: 2406MHz-2446MHz Sequence 3: 2432MHz-2472MHz Sequence 4: 2406MHz-2472MHz
RX Frequency
Sequence 1: 2406MHz-2472MHz Sequence 2: 2406MHz-2446MHz Sequence 3: 2432MHz-2472MHz Sequence 4: 2406MHz-2472MHz
Input Rated Voltage
For transmitter: Rated Input: 5.0VDC from an external power adapter Adapter Model Number.:YLS0041A-E050055 Adapter input: 100-240VAC,50/60Hz, 0.3A Output: 5.0VDC, 550mA For Headphone: 2.4VDC (supplied by AAA 1.2V rechargeable battery*2)
EUT Accessory Audio-in cable, battery*2
3.2 EUT Appearance
Appearance of DHP380
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 9 of 40
4 System Configuration during EMC Test
4.1 Test Configurations The applicant has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was in this test report and defined as:
Test Mode
TC 1 TM1
TC2 TM2
.
4.2 Test Mode TM1: Charging TM2: Wireless Operating
4.3 Configurations of Test System
Configurations of Test 1
Configurations of Test 2
EUT
Adapter
AC mains
EUT(transmitter)
Adapter
AC mains Audio source
EUT(Receiver)
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 10 of 40
4.4 Associated Equipment Used during Test
Name Model Manufacturer S/N Cal Due Date
Mobile phone --- --- -- --
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 11 of 40
5 Electromagnetic Interference (EMI)
5.1 Radiated Disturbance 30MHz to 6000MHz 5.1.1 Test Procedure
The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to the standards: ANSI C63.4. The test distance was 3m for 30 ~ 1GHz. The test site full-anechoic chamber has met the requirement of VSWR tolerance 6dB according to the standards: CISPR 16-1-4. The test distance was 3m for 1GHz ~ 6GHz. The set-up and test methods were according to EN 55022/CISPR 22 A preliminary scan and a final scan of the emissions were made from 30 MHz to 1GHz by using test script of software; the emissions were measured using Quasi-Peak Detector (30MHz~1GHz) and AV/PK Detector (above 1GHz).. The maximal emission value was acquired by adjusting the antenna height, polarisation and turntable azimuth in accordance with the software setup. Normally, the height range of antenna was 1m to 4m, the azimuth range of turntable was 0°to 360°, The receive antenna has two polarizations V and H.
5.1.2 Test Setup
Figure 1. Test set-up of radiated disturbance(30MHz-1GHz)
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 12 of 40
Figure 2. Test set-up of radiated disturbance(above 1GHz)
5.1.3 Test Results
The EUT has met the requirements for Radiated Emission of enclosure port. The test data see section 9.1 of this report.
Test Limits
Frequency (MHz)
Distance (m)
QP (dBuV/m)
30 - 230 3 40
230 - 1000 3 47
Frequency (GHz)
Distance (m)
Average (dBuV/m)
Peak (dBuV/m)
1-3 3 50 70
3-6 3 54 74
Test environment condition:
Performed Item Item Required Actual
Radiated Emission
Ambient temperature 15C~35C 25.6C
Relative humidity 25%~75% 61.3%
Atmospheric pressure 86 kPa~106kPa 101.2kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 13 of 40
5.2 Conducted Disturbance 0.15 MHz to 30MHz On AC Port 5.2.1 Test Procedure
The EUT was configured as described in section 4 for this test. The mains cable of the EUT being measured shall be connected to LISN, The LISN shall be placed 0.8m from the boundary of EUT and bonded to a ground reference plane for LISN mounted on top of the ground reference plane. This distance is between the closest points of the LISN and the EUT. All other units of the EUT and associated equipment shall be at least 0.8m from the LISN. All telecommunication and signal ports must be correctly terminated using either appropriate associated equipment or a representative termination during the measurement of the conducted disturbances at the mains. Ground connections, where required for safety purposes, shall be connected to the reference ground point of the LISN and, where not otherwise provided or specified by the manufacturer, shall be of same length as the mains cable and run parallel to the mains connection at a separation distance of not more than 0.1m. The set up of Conducted Disturbance for telecommunication port was according to Annex C of EN 55022/CISPR 22.
5.2.2 Test Setup
Figure 3. Test set-up of conducted disturbance for power port
5.2.3 Test Results
The EUT has met requirements for Conducted disturbance. The test data see section 9.2 of this report.
Test Limit of AC Power Port
Frequency range 150kHz ~ 30MHz
Frequency Voltage limits
QP AV
0.15MHz~0.5MHz 66-56dBμV 56-46 dBµV
0.5MHz-5MHz 56dBμV 46 dBµV
5MHz~30MHz 60dBμV 50 dBµV
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 14 of 40
5.3 Current Harmonics Emissions 5.3.1 Test Procedure
The EUT is to be powered from a clean (low distortion) 230V 50Hz AC Power Port source. The EUT was configured as described in section 4 for this test. The set-up and test methods were according to EN 61000-3-2/IEC 61000-3-2.
5.3.2 Test Setup
Figure 4. Test set-up of current harmonics emission test
5.3.3 Test Results
The EUT has met the requirements of EN 61000-3-2/IEC 61000-3-2 for harmonics of AC Power Port. The EUT has power less than 75W. Hence according to EN 61000-3-2, the EUT belong to equipment with a rated power of 75W or less’, therefore ‘limits are not specified in this edition of the standards’.
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 15 of 40
5.4 Voltage Fluctuations (Flicker) 5.4.1 Test Procedure
The EUT is to be powered from a clean (low distortion) 230V 50Hz AC Power Port source. The EUT was configured as described in section 4 for this test. The formal test ran 10mins and over a 2 hour period. The values of Pst, d(t), dmax and dc is measured. Power’s source impedence is 0.4+j0.25Ω. The set-up and test methods were according to EN 61000-3-3/IEC 61000-3-3.
5.4.2 Test Setup
Figure 5. Test set-up of voltage fluctuations test
5.4.3 Test Results
The EUT has met the requirements of EN 61000-3-3/IEC 61000-3-3 for voltage fluctuations of AC Power Port. Test environment condition:
Performed Item Item Required Actual
Voltage Fluctuations
Ambient temperature 15C~35C 24.5C
Relative humidity 25%~75% 45.0%
Atmospheric pressure 86 kPa~106kPa 100.5kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 16 of 40
6 Electromagnetic Susceptibility (EMS)
6.1 Immunity to Electrostatic Discharge 6.1.1 Test Procedure
The EUT was configured as described in section 4 for this test. The set-up and test methods were according to IEC 61000-4-2.
6.1.2 Test Set up
Figure 6. Test set-up of electrostatic discharge
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 17 of 40
6.1.3 Test Results
Details of the points tested were presented in below:
Test Results
Test Points
Specification Level
Conclusion ±2kV,±4kV Contact
Discharges ±2kV,±4kV, ±8kV Air
Discharges
Positive Negative Positive Negative
Indirect Contact
Indirect Contact, HCP(left, right, front, rear)
√ √ N/A N/A Pass
Indirect Contact, VCP(left, right, front, rear)
√ √ N/A N/A Pass
Direct Contact/ Air Contact
Metal charging point N/A N/A Pass
Audio-in port N/A N/A Pass
DC-in port N/A N/A Pass
Screw N/A N/A Pass
button N/A N/A Pass
Gaps N/A N/A Pass
Lights N/A N/A Pass
Switch N/A N/A Pass
√ The EUT's performance was not impaired at this test point when the ESD pulse was applied. Test environment condition:
Performed Item Item Required Actual
Immunity to Electrostatic Discharge
Ambient temperature 15C~35C 24.7C
Relative humidity 30%~60% 63.3%
Atmospheric pressure 86 kPa~106kPa 100.5kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 18 of 40
6.2 Immunity to Radiated Electric Fields 80MHz to 2700MHz 6.2.1 Test Procedure
The EUT was configured as described in section 4 for this test. The set-up and test methods were according to IEC 61000-4-3. All sides of the EUT (front, rear, left and right) were tested by antenna with vertical and horizontal polarization.
6.2.2 Test Setup
Figure 7. Test set-up of Immunity to Radiated Electric Fields
6.2.3 Test Results
Test Results of Radiated Electric Fields
Test side of EUT Front, Rear, Left, Right
Criterion CT&CR
Frequency range & Test Level
80MHz –1000MHz
test level:3 V/m(Unmodulated, rms)
1400MHz –2700MHz
test level:3 V/m(Unmodulated, rms)
Modulation 80% AM, 1kHz
Conclusion Pass
Test environment condition:
Performed Item Item Required Actual
Immunity to Radiated
Electric Fields
Ambient temperature 15C~35C 24.7C
Relative humidity 25%~75% 63.9%
Atmospheric pressure 86 kPa~106kPa 100.4kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 19 of 40
6.3 Immunity to Electrical Fast Transient Bursts 6.3.1 Test Procedure
The EUT was configured as described in section 4 for this test. A series of Fast Transient Bursts meeting the specification were applied for a period of 120 seconds. The Transient Bursts were applied for both Positive and Negative Burst Trains to Power Port. The set-up and test methods were according to IEC 61000-4-4.
6.3.2 Test Setup
Figure 8. Test set-up of immunity to electrical fast transient bursts
6.3.3 Test Results
Test Results of Electrical Fast Transient Bursts
Ports Measuring condition
Couple mode Description Conclusion
AC Power Port Level:±1.0kV, Tr/Th: 5/50ns, 5kHz Interval: 120 seconds
No fail detected
Pass
Telecommunication Port
Level:±1.0kV, Tr/Th: 5/50ns, 100kHz Interval: 120 seconds
N/A N/A
Test environment condition:
Performed Item Item Required Actual
Immunity to Electrical Fast
Transient Bursts
Ambient temperature 15C~35C 23.0C
Relative humidity 25%~75% 60.8%
Atmospheric pressure 86 kPa~106kPa 101.3kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 20 of 40
6.4 Immunity to Surges 6.4.1 Test Procedure
The EUT was configured as described in section 4 for this test. A series of High Energy Surges were applied to Power Port. The set-up and test methods were according to IEC 61000-4-5.
6.4.2 Test Setup
Figure 9. Test set-up of immunity to surge
6.4.3 Test Results
Test Results of Surges
Ports Measuring condition Description Conclusion
AC Power Port Line to Line: L-N Level:±1.0kV, Tr/Th:1.2/50μs Interval: 60 seconds Phase: Sync
No fail detected
Pass
Signal Port Level:±1.0kV, Tr/Th:1.2/50μs Interval: 60 seconds
N/A N/A
Test environment condition:
Performed Item Item Required Actual
Immunity to Surges
Ambient temperature 15C~35C 23.3C
Relative humidity 25%~75% 56.0%
Atmospheric pressure 86 kPa~106kPa 101.0kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 21 of 40
6.5 Immunity to Continuous Conducted Interference 0.15MHz to 80MHz 6.5.1 Test Procedure
The EUT was configured as described in section 4 for this test. The applied level was Amplitude Modulated by a 1 kHz sinusoidal signal to a modulation depth of 80%. The set-up and test methods were according to IEC 61000-4-6.
6.5.2 Test Setup
Figure 10. Test set-up of immunity to continuous conducted interference
6.5.3 Test Results
The test data of audio breakthrough see section 8.4 of this report.
Test Results of Continuous Conducted Interference
Ports Measuring condition Inject
method Description Conclusion
AC Power Port
Frequency range: 0.15 MHz to 80 MHz Induced voltage :3 V (rms) Special frequency point: 0.2MHz;1.0MHz;7.1MHz;13.56MHz;21.0MHz;27.12MHz;40.68MHz(±1%)
CDN M2 No fail
detected Pass
Signal port
Frequency range: 0.15 MHz to 80 MHz Induced voltage :3 V (rms) Special frequency point: 0.2MHz;1.0MHz;7.1MHz;13.56MHz;21.0MHz;27.12MHz;40.68MHz(±1%)
Clamp N/A N/A
Test environment condition:
Performed Item Item Required Actual
Immunity to Continuous Conducted Interference
Ambient temperature 15C~35C 23C
Relative humidity 25%~75% 60.8%
Atmospheric pressure 86 kPa~106kPa 101.3kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 22 of 40
6.6 Immunity to Voltage Dips and Short Interruption of AC Power Port 6.6.1 Test Procedure
The EUT was configured as described in section 4 for this test. The set-up and test methods were according to IEC 61000-4-11.
6.6.2 Test Setup
Figure 11. Test set-up of Voltage Dips and Short Interruption of AC Power Port
6.6.3 Test Results
In the case where the equipment is fitted with or connected to a battery back-up, the performance criteria for transient phenomena shall apply. In the case where the equipment is powered solely from the AC mains supply (without the use of a parallel battery back-up) volatile user data may have been lost and if applicable the communication link need not to be maintained and lost functions should be recoverable by user or operator; no unintentional responses shall occur at the end of the test.
Test Results of Voltage Dips and Short Interruption
Ports Measuring condition Performance
Criterion Description Conclusion
AC Power
Port
Voltage dip: 70 % residual voltage for 25 cycles (at 50 Hz)
TT&TR No fail
detected Pass
Voltage dip: 0 % residual voltage for 0,5 cycle
TT&TR No fail
detected Pass
Voltage dip: 0 % residual voltage for 1 cycle
TT&TR No fail
detected Pass
Voltage interruption: 0 % residual voltage for 250 cycles (at 50 Hz)
TT&TR No fail
detected Pass
Test environment condition:
Performed Item Item Required Actual
Immunity to Voltage Dips and Short Interruption
Ambient temperature 15C~35C 23.3C
Relative humidity 25%~75% 56.0%
Atmospheric pressure 86 kPa~106kPa 101.0kPa
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 23 of 40
7 Main Test Instruments
Test item
Test Instrument Model Manufacturer Cal. Due Date
CE
EMI Test Receiver ESR 3 Rohde & Schwarz
2016-7-24
LISN ENV216 Rohde & Schwarz
2016-7-24
RE
EMI Test Receiver ESR 26 Rohde & Schwarz
2016-7-24
Trilog Super Broadband Test
Antenna VULB 9163 Schwarzbeck 2016-8-14
Horn Antenna HF907 Rohde & Schwarz
2016-7-24
Pre-amplifier SCU 18 Rohde & Schwarz
2016-7-24
3m Semi-anechoic chamber
9X6X6 TDK 2019-5-29
Current Harmonic Voltage
fluctuation Flicker
Three Phase Harmonic flicker
test system
MX45-3PI-400-413-CTSHL-LF-
SNK CI 2016-7-24
RS
Signal Generator SMB100A Rohde & Schwarz
2016-7-24
Power Amplifier BBA150 Rohde & Schwarz
2016-7-24
Log-Periodic Antenna
HL046E Rohde & Schwarz
NCR
Fully Anechoic Chamber
8X4X4 TDK 2019-8-29
CS
Continuous Wave Simulator
CWS 500N1 EMTEST 2016-7-24
Attenuator ATT6/80 EMTEST 2016-7-24
CDN CDN-M2/M3 EMTEST 2016-7-24
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 24 of 40
Surge
Immunity simulator UCS 500N7 EMTEST 2016-7-24
4kV coupling/decouplin
g network CNV 504 N1 EMTEST 2016-7-24
4kV CDN for 8 telecom lines
CNV 504 S1 EMTEST 2016-7-24
EFT
Immunity simulator UCS 500N7 EMTEST 2016-7-24
7kV Coupling network 3-phase
CNI 503B5 EMTEST 2016-7-24
Capacitive Coupling Clamp
HFK EMTEST 2016-7-24
ESD ESD tester ESS-2002 Noiseken 2016-8-14
DIPS
Immunity simulator UCS 500N7 EMTEST 2016-7-24
Motorized Variac MV2616 EMTEST 2016-7-24
Switch-Box fo phase by phase
PFLS 32N1 EMTEST 2016-7-24
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 25 of 40
8 System Measurement Uncertainty
For a 95% confidence level, the measurement expanded uncertainties for defined systems, in accordance with the recommendations of ISO 17025 were:
System Measurement Uncertainty
Items Extended Uncertainty
Radiated Emission in 3m chamber 30MHz-1000MHz
Horizontal: 4.83dB; Vertical: 4.91dB;
CE 3.50dB
Uncertainty for Harmonic test 3.26%
Uncertainty for Flicker test 4.76%
Uncertainty for RS test 19%, K=2
Uncertainty for CS test 29%, K=2
Uncertainty for ESD test The immunity measurement system uncertainty is within standard requirement and is based on a
standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of
approximately 95%.
Uncertainty for EFT test
Uncertainty for Surges test
Uncertainty for Voltage Dips, Voltage Variations and Short Interruptions Test
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 26 of 40
9 Graph and Data of Emission Test
9.1 Radiated Disturbance 9.1.1 30MHz~1GHz EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC1 Test Specification: Horizontal
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
3 0 M 5 0 6 0 8 0 1 0 0 M 2 0 0 3 0 0 4 0 0 5 0 0 8 0 0 1 G
Level in
dB
µV
/m
Frequenc y in H z
Critical_Freqs
Frequency (MHz)
MaxPeak (dBµV/m)
Limit (dBµV/m)
Margin (dB)
Height (cm)
Pol Azimuth (deg)
132.092500 17.95 40.00 22.05 200.0 H 127.0
294.931250 24.51 47.00 22.49 100.0 H 0.0
417.818125 29.14 47.00 17.86 100.0 H 336.0
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 27 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC1 Test Specification: Vertical
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
3 0 M 5 0 6 0 8 0 1 0 0 M 2 0 0 3 0 0 4 0 0 5 0 0 8 0 0 1 G
Level in
dB
µV
/m
Frequenc y in H z
Critical_Freqs Frequency
(MHz) MaxPeak (dBµV/m)
Limit (dBµV/m)
Margin (dB)
Height (cm)
Pol Azimuth (deg)
42.246250 24.83 40.00 15.17 100.0 V 0.0
48.611875 22.41 40.00 17.59 100.0 V 15.0
132.092500 27.95 40.00 12.05 100.0 V 63.0
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 28 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC2 Test Specification: Horizontal
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
3 0 M 5 0 6 0 8 0 1 0 0 M 2 0 0 3 0 0 4 0 0 5 0 0 8 0 0 1 G
Level in
dB
µV
/m
Frequenc y in H z
Critical_Freqs
Frequency (MHz)
MaxPeak (dBµV/m)
Limit (dBµV/m)
Margin (dB)
Height (cm)
Pol Azimuth (deg)
39.881875 33.05 40.00 6.95 100.0 V 265.0
143.975000 27.25 40.00 12.75 200.0 V 88.0
256.010000 33.45 47.00 13.55 200.0 V 161.0
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 29 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC2 Test Specification: Vertical
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
3 0 M 5 0 6 0 8 0 1 0 0 M 2 0 0 3 0 0 4 0 0 5 0 0 8 0 0 1 G
Level in
dB
µV
/m
Frequenc y in H z
Critical_Freqs Frequency
(MHz) MaxPeak (dBµV/m)
Limit (dBµV/m)
Margin (dB)
Height (cm)
Pol Azimuth (deg)
156.645625 35.78 40.00 4.22 100.0 V 0.0
162.815625 37.66 40.00 2.34 115.0 V 39.0
491.538125 37.64 47.00 9.36 100.0 V 0.0
Final_Result Frequency
(MHz) QuasiPeak (dBµV/m)
Limit (dBµV/m)
Margin (dB)
Height (cm)
Pol Azimuth (deg)
162.815625 34.30 40.00 5.70 115.0 V 39.0
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 30 of 40
9.2 Conducted Disturbance 9.2.1 Conducted Emission Test Data EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC1 Test Specification: L
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
1 5 0 k 3 0 0 4 0 05 0 0 8 0 01 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Level in
dB
µV
Frequenc y in H z
E N 3 0 1 4 8 9 V O L T A GE M A IN S Q P
E N 3 0 1 4 8 9 V O L T A GE M A IN S A V
Critical_Freqs
Frequency (MHz)
MaxPeak (dBµV)
Limit (dBµV)
Margin (dB)
Line Corr. (dB)
0.346000 44.14 59.06 14.92 L1 10.2
2.498000 41.92 56.00 14.08 L1 9.8
3.178000 45.01 56.00 10.99 L1 9.8
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 31 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC1 Test Specification: N
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
1 5 0 k 3 0 0 4 0 05 0 0 8 0 01 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Level in
dB
µV
Frequenc y in H z
E N 3 0 1 4 8 9 V O L T A GE M A IN S Q P
E N 3 0 1 4 8 9 V O L T A GE M A IN S A V
Final_Result
Frequency (MHz)
QuasiPeak (dBµV)
Average (dBµV)
Limit (dBµV)
Margin (dB)
Line Corr. (dB)
0.337500 --- 33.82 49.26 15.44 N 10.1
0.337500 42.88 --- 59.26 16.38 N 10.1
0.965500 --- 24.67 46.00 21.33 N 9.8
0.965500 34.96 --- 56.00 21.04 N 9.8
2.270500 --- 28.95 46.00 17.05 N 9.8
2.270500 39.04 --- 56.00 16.96 N 9.8
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 32 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC2 Test Specification: L
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
1 5 0 k 3 0 0 4 0 05 0 0 8 0 01 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Level in
dB
µV
Frequenc y in H z
E N 3 0 1 4 8 9 V O L T A GE M A IN S Q P
E N 3 0 1 4 8 9 V O L T A GE M A IN S A V
Critical_Freqs Frequency
(MHz) MaxPeak (dBµV)
Limit (dBµV)
Margin (dB)
Line Corr. (dB)
0.334000 40.94 59.35 18.41 L1 10.2
1.498000 35.82 56.00 20.18 L1 9.8
2.842000 42.06 56.00 13.94 L1 9.8
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 33 of 40
EUT: 2.4GHz Digital Headphone M/N: DHP380 Operating Condition: TC2 Test Specification: N
0
1 0
2 0
3 0
4 0
5 0
6 0
7 0
8 0
1 5 0 k 3 0 0 4 0 05 0 0 8 0 01 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Level in
dB
µV
Frequenc y in H z
E N 3 0 1 4 8 9 V O L T A GE M A IN S Q P
E N 3 0 1 4 8 9 V O L T A GE M A IN S A V
Final_Result Frequency
(MHz) QuasiPeak
(dBµV) Average (dBµV)
Limit (dBµV)
Margin (dB)
Line Corr. (dB)
0.341500 --- 34.28 49.17 14.89 N 10.1
0.341500 44.91 --- 59.17 14.26 N 10.1
1.097500 --- 26.17 46.00 19.83 N 9.8
1.097500 36.18 --- 56.00 19.82 N 9.8
1.825500 --- 26.00 46.00 20.00 N 9.8
1.825500 36.02 --- 56.00 19.98 N 9.8
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 34 of 40
9.3 Current Harmonics Emissions This test was carried out in all the test modes, here only the worst test result was shown. 9.3.1 Test Data of Voltage Fluctuation and Flicker Test Result: Pass Source qualification: Normal Current(blue) & voltage(green) waveforms
- 0 . 4
- 0 . 2
0 . 0
0 . 2
0 . 4
- 3 0 0
- 2 0 0
- 1 0 0
0
1 0 0
2 0 0
3 0 0
Cu
rr
en
t
(A
mp
s)
Vo
lta
ge
(
Vo
lts
)
Harmonics and Class A limit line European Limits – 100%(blue) & 150%(red)
0 . 0
0 . 5
1 . 0
1 . 5
2 . 0
2 . 5
3 . 0
3 . 5
Cu
rr
en
t
RM
S(
Am
ps
)
H a r m o n i c #4 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0
Test result: Pass Worst harmonic was #10 with 1.87% of the limit. Test Result: Pass Source qualification: Normal THC: 0.014 A I-THD: 198.0 % POHC(A): 0.000 A POHC Limit(A): 0.251 A Highest parameter values during test: V_RMS (Volts): 229.938 Frequency(Hz): 50.00 I_Peak (Amps): 0.207 I_RMS (Amps): 0.028 I_Fund (Amps): 0.011 Crest Factor: 8.650 Power (Watts): 2.5 Power Factor: 0.525
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 35 of 40
9.4 Voltage Fluctuation and Flicker This test was carried out in all the test modes, here only the worst test result was shown. 9.4.1 Test Data of Voltage Fluctuation and Flicker
Psti and limit line European Limits
0 . 2 5
0 . 5 0
0 . 7 5
1 . 0 0
Ps
t
16
:2
4:
06
Plt and limit line
0 . 2 5
0 . 5 0
Plt
16
:2
4:
06
Parameter values recorded during the test:
Vrms at the end of test (Volt): 229.91 Highest dt (%): 0.00 Test limit (%): N/A N/A T-max (mS): 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.05 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.162 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.071 Test limit: 0.650 Pass
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 36 of 40
10 Setup Photographs of EUT 10.1.1 Radiated Emission
Radiated Disturbance Emissions (30MHz-1GHz)
10.1.2 Conducted Emissions
Conducted Emission test AC port
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 37 of 40
10.1.3 Harmonics and Voltage Fluctuations (Flicker)
Harmonic and Flicker for AC port
10.1.4 Immunity
Immunity to Radiated Electric Fields 80MHz-2700MHz
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 38 of 40
Immunity to Electrostatic Discharge
Immunity to Electrical Fast Transient for AC power Port
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 39 of 40
Immunity to Surge for AC Power port
Immunity to Continuous Conducted Interference for AC power Port
Report Number: 68.720.15.005.01
EMC_SZ_FR_08.00 E-I Release 2014-03-20
TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299
Page 40 of 40
Immunity to Dips test