emc radio test report per en 301 489-1 v1.8.1 and en 301 ... · en 301 489-1 v1.8.1 en 301 489-17...
TRANSCRIPT
Test Certificate A sample of the following product received on May 19, 2011 and tested on May 19 and 31, 2011 and March 5, 2012 complied with the requirements of, EN 301 489-1 V1.8.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements”
EN 301 489-17 V2.1.1 “Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems”
given the measurement uncertainties as detailed in Elliott report R86850.
Summit Data Communications
Model SDC-SSD40NBT _____________________ _______________________ Mark E Hill Summit Data Communications Staff Engineer _______________________ Printed Name
Elliott Laboratories is accredited by the A2LA, certificate number 0214.26, to perform the test(s) listed in this report, except where noted otherwise. This report and the information contained herein represent the results of testing test articles identified and selected by the client performed to specifications and/or procedures selected by the client. National Technical Systems (NTS) makes no representations, expressed or implied, that such testing is adequate (or inadequate) to demonstrate efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it represent any statement whatsoever as to its merchantability or fitness of the test article, or similar products, for a particular purpose. This report shall not be reproduced except in full
Elliott Laboratories, LLC an NTS Company 41039 Boyce Road 510-578-3500 Phone www.elliottlabs.com Fremont, CA. 94538 510-440-9525 Fax
EMC Test Report
EN 301 489-1 v1.8.1 EN 301 489-17 V2.1.1
Model: SDC-SSD40NBT COMPANY: Summit Data Communications 526 South Main St. Suite 805 Akron, OH 44311 TEST SITE(S): Elliott Laboratories 41039 Boyce Road. Fremont, CA. 94538-2435 REPORT DATE: March 20, 2012 FINAL TEST DATES: May 19 and 31, 2011 and March 5, 2012 TOTAL NUMBER OF PAGES: 38 PROGRAM MGR / QUALITY ASSURANCE DELEGATE / TECHNICAL REVIEWER: FINAL REPORT PREPARER: ______________________________ ______________________________ Mark E Hill David Guidotti Staff Engineer Senior Technical Writer
Elliott Laboratories is accredited by the A2LA, certificate number 0214.26, to perform the test(s) listed in this report, except where noted otherwise. This report and the information contained herein represent the results of testing test articles identified and selected by the client performed to specifications and/or procedures selected by the client. National Technical Systems (NTS) makes no representations, expressed or implied, that such testing is adequate (or inadequate) to demonstrate efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it represent any statement whatsoever as to its merchantability or fitness of the test article, or similar products, for a particular purpose. This report shall not be reproduced except in full
File: R86850 Page 2
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
REVISION HISTORY Rev# Date Comments Modified By
- 03-20-2012 First release
File: R86850 Page 3
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
TABLE OF CONTENTS
TEST CERTIFCATE .................................................................................................................................................. 1
COVER PAGE............................................................................................................................................................. 2
REVISION HISTORY ................................................................................................................................................ 3
TABLE OF CONTENTS ............................................................................................................................................ 4
SCOPE .......................................................................................................................................................................... 5
OBJECTIVE ................................................................................................................................................................ 5
STATEMENT OF COMPLIANCE ........................................................................................................................... 5
DEVIATIONS FROM THE STANDARD ................................................................................................................ 6
TEST RESULTS .......................................................................................................................................................... 7 EMISSIONS TESTING ............................................................................................................................................ 7 IMMUNITY TESTING ............................................................................................................................................ 8
MEASUREMENT UNCERTAINTIES ..................................................................................................................... 9
EQUIPMENT UNDER TEST (EUT) DETAILS .................................................................................................... 10 GENERAL .............................................................................................................................................................. 10 OTHER EUT DETAILS ......................................................................................................................................... 10 EUT CLASSIFICATION ....................................................................................................................................... 10 ENCLOSURE ......................................................................................................................................................... 10 MODIFICATIONS ................................................................................................................................................. 10 SUPPORT EQUIPMENT ....................................................................................................................................... 11 EUT INTERFACE PORTS .................................................................................................................................... 11 EUT OPERATION DURING IMMUNITY TESTING ......................................................................................... 11 EUT PERFORMANCE CRITERIA ....................................................................................................................... 12
IMMUNITY TEST DESCRIPTIONS ..................................................................................................................... 13 GENERAL INFORMATION ................................................................................................................................. 13
MEASUREMENT INSTRUMENTATION ............................................................................................................ 13 ELECTROSTATIC DISCHARGE TEST SYSTEM .............................................................................................. 13 ELECTROMAGNETIC FIELD TEST SYSTEM .................................................................................................. 13 INSTRUMENT CALIBRATION ........................................................................................................................... 13
IMMUNITY TEST PROCEDURES ....................................................................................................................... 14 EQUIPMENT PLACEMENT ................................................................................................................................ 14 APPLICATION OF ELECTROSTATIC DISCHARGES ..................................................................................... 14 APPLICATION OF ELECTROMAGNETIC FIELD ............................................................................................ 14
APPENDIX A TEST EQUIPMENT CALIBRATION DATA .............................................................................. 15
APPENDIX B TEST DATA LOG SHEETS ........................................................................................................... 16
END OF REPORT .................................................................................................................................................... 38
File: R86850 Page 4
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
SCOPE The European Committee for Electrotechnical Standardization (CENELEC), the European Telecommunications Standards Institute (ETSI) and the International Electrotechnical Commission (IEC) publish standards regarding the electromagnetic compatibility of electronic devices. Electromagnetic compatibility tests have been performed on the Summit Data Communications model SDC-SSD40NBT in accordance with these standards. The tests were performed in accordance with the current, published versions of the basic standards referenced in the following standards, as outlined in Elliott Laboratories test procedures. The test data has been provided as an appendix to this report for reference. Standard Title Date EN 301 489-1 Electromagnetic compatibility and Radio spectrum
Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements
2008-04 (V1.8.1)
EN 301 489-17 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission Systems
2009-05 (V2.1.1)
OBJECTIVE
The objective of the manufacturer is to declare conformity with one of the essential requirements of the R&TTE Directive 1999/5/EC. In order to demonstrate compliance, the manufacturer or a contracted laboratory makes measurements and takes the necessary steps to ensure that the equipment complies with the appropriate technical standards.
STATEMENT OF COMPLIANCE
The tested sample of Summit Data Communications model SDC-SSD40NBT, given the performance criteria as specified by the manufacturer, complied with the requirements of the following standard(s):
Standard/Regulation Version Standard Date EN 301 489-1 1.8.1 2008-04 EN 301 489-17 2.1.1 2009-05
The test results recorded herein are based on a single type test of the Summit Data Communications model SDC-SSD40NBT and therefore apply only to the tested sample. The sample was selected and prepared by Ron Seide of Summit Data Communications Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product that could result in increased emissions should be checked to ensure compliance has been maintained (i.e., printed circuit board layout changes, different enclosure, different line filter or power supply, harnessing and/or interface cable changes, etc.).
File: R86850 Page 5
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
DEVIATIONS FROM THE STANDARD
No deviations were made from the published requirements listed in the scope of this report.
File: R86850 Page 6
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
TEST RESULTS
The following tests were performed on the Summit Data Communications model SDC-SSD40NBT. The results are based upon performance criteria defined by the manufacturer. The actual test results and associated performance criteria are contained within an appendix of this report.
EMISSIONS TESTING
Test Port Basic
Standard Level
(Margin) Status
Radiated Emissions 30MHz – 6GHz Enclosure EN 55022 - Not Applicable
Note 1
Conducted Emissions 0.15 – 30MHz
AC Power
EN 55022 - Not Applicable Note 2
Harmonic Current Emissions EN 61000-3-2 - Not Applicable
Note 2
Voltage Fluctuations EN 61000-3-3 - Not Applicable Note 2
Conducted Emissions 0.15 – 30MHz DC Power EN 55022 - Not Applicable
Note 4
Conducted Emissions 0.15 – 30 MHz
Telecommunications Ports EN 55022 - Not Applicable
Note 5
Note 1 This test is only applicable to ancillary equipment. The radiated emissions requirements for radio equipment are covered under the Radio standard.
Note 2 The EUT does not have an AC power port. Note 3 The EUT’s AC power supply is rated at less than 50W. Note 4 The EUT does not have a DC power port that would connect to a cable longer than 3m. Note 5 The EUT does not have any telecommunication ports.
File: R86850 Page 7
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
IMMUNITY TESTING
Test Basic Standard Level Required Level Tested Criterion
Met Status ElectroStatic Discharge EN 61000-4-2 4 kV CD,
8 kV AD 4 kV CD, 8 kV AD B / TT / TR Complied
Radio frequency Electromagnetic Field EN 61000-4-3
80-1000 MHz 1400-2700 MHz
3 V/m 80% 1 kHz AM
80-1000 MHz 1000-2700 MHz
3 V/m 80% 1 kHz AM
A / CT / CR Complied
Fast Transients AC Power Ports EN 61000-4-4 1 kV N/A – Note 1
Fast Transients DC Power Ports EN 61000-4-4 1kV N/A – Note 1
Fast Transients Telecommunications / Signal / Control Ports
EN 61000-4-4 0.5kV N/A – Note 2
Surge, AC Power Port EN 61000-4-5 2kV CM / 1kV DM N/A – Note 1 Surge Transients Telecommunications Ports ( indoor cables)
EN 61000-4-5 0.5kV N/A – Note 2
Surge Transients Telecommunications Ports (outdoor cables)
EN 61000-4-5 1.0kV N/A – Note 2
Vehicular Surges ISO 7637-1, ISO 7637-2 Note 4
Radio Frequency Common Mode AC Power Ports
EN 61000-4-6
0.15-80 MHz, 3 Vrms
80% 1 kHz AM
N/A – Note 1
Radio Frequency Common Mode DC Power Ports
EN 61000-4-6 N/A – Note 1
Radio Frequency Common Mode Telecommunications/ Signal / Control Ports
EN 61000-4-6 N/A – Note 2
Voltage Dips and Interrupts EN 61000-4-11
100%/ ½-cycle 100%/ 1-cycle 30% /25-cycles
100%/250-cycles
N/A – Note 1
Note 1 The EUT is powered directly from a host system. Testing not performed. Note 2 The EUT does not have any signal ports that are intended to connect to cables longer than 3m in length Note 3 The EUT is not intended to be used in a vehicular environment
File: R86850 Page 8
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
MEASUREMENT UNCERTAINTIES ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the test results be included in the report. The measurement uncertainties given below are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a 95% confidence level and were calculated in accordance with NAMAS document LAB 34. For emissions tests, the uncertainties were calculated using the approach described in CISPR 16-4-2:2003 and the levels were found to be below levels of Ucispr and therefore no adjustment of the data for measurement uncertainty is required.
Measurement Type Measurement Unit Frequency Range Expanded Uncertainty
Conducted Emissions dBuV 0.15 to 30 MHz ± 2.4 dB Radiated Emissions dBuV/m 30 to 1000 MHz ± 3.6 dB AC Current Harmonics Amps 50 to 2,000 Hz ± 0.12 %
AC Voltage Flicker Voltage N/A ± 0.12 % Pst, Plt N/A ± 3.46 %
Radiated Immunity V/m 80 – 2500 MHz - 26.3%, + 29.97% ESD KV N/A ± 8.6%
Fast Transients Voltage N/A ± 5.98 % Timing N/A ± 8.60 %
Surge Voltage N/A ± 4.92 % RF Common Mode (CDN method) Vrms 0.15 –80 MHz -12.64 %, +13.33 % RF Common Mode (BCI method) Vrms 0.15 –80 MHz -13.45 %, +15.32 %
Voltage Dips Voltage N/A ± 2.32 % Timing N/A ± 0.08mS
File: R86850 Page 9
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
EQUIPMENT UNDER TEST (EUT) DETAILS GENERAL
The Summit Data Communications model SDC-SSD40NBT is an 802.11abgn 1x1 with Bluetooth 2.1 module. The sample was received on May 19, 2011 and tested on May 19 and 31, 2011 and March 5, 2012. The EUT consisted of the following component(s):
Manufacturer Model Description Serial Number
Summit SDC-MSD40NBT 802.11abgn 1x with BT Prototype
OTHER EUT DETAILS
The SSD40NBT Module was tested on a MSD40NBT board. The EUT supports 20MHz operation only. The EUT supports the following antennas: Monopole Antenna - 2.4 and 5GHz bands - Huber+Suhner, SOA 2459/360/5/0/V_C, 3dBi (2.4GHz), 6.5dBi (5GHz) Dipole Antenna #1 - 2.4 and 5GHz bands - Larsen, R380.500.314, 1.6dBi (2.4GHz), 5dBi (5GHz) Dipole Antenna #2 - 2.4 GHz only - Cisco Air-Ant 4941 2dBi(2.4GHz) Magnetic Dipole - 2.4GHz and 5GHz bands – Ethertronics, 2.5dBi (2.4GHz), 5dBi (5GHz)
EUT CLASSIFICATION
The EUT is a radio module that can be used in either fixed use or portable applications. ENCLOSURE
The EUT has no enclosure. It is designed to be installed within the enclosure of a host computer.
MODIFICATIONS
The EUT did not require modifications during testing in order to comply with the immunity specification.
File: R86850 Page 10
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
SUPPORT EQUIPMENT
The following equipment was used as local support equipment for immunity testing:
Manufacturer Model Description Serial Number Delta Electronics EADP-10BB AC/DC Adapter 59A401Z9UP42K
HP HSTNH-F02X PDA Docking Station E9C3B0AZDUJ07F HP iPaQ PDA 2CK702010G
The following equipment was used as remote support equipment for immunity testing:
Stand-By Mode
Manufacturer Model Description Serial Number Dell PP41L Laptop -
Cisco AIR-AP1131AG-A-
K9
Access Point FTX1040T17J
Airlink AR430W Router 30008256167
EUT INTERFACE PORTS
The I/O cabling configuration during immunity testing was as follows:
Port Connected To Cable(s) Description Shielded or Unshielded Length(m)
DC Power In (Docking Station)
AC/DC Adapter Multiconductor Unshielded 1.5m
USB (Docking Station)
Unterminated Multiconductor Shielded 1.5m
AC/DC Adapter AC Mains - - -
EUT OPERATION DURING IMMUNITY TESTING
During testing in Stand-by Mode: The EUT was monitored with a spectrum analyzer and a near field probe or antenna. During testing in transceiver mode: The EUT was configured to continuously ping to the laptop connected to the remote AP over the wireless connection.
File: R86850 Page 11
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
EUT PERFORMANCE CRITERIA
Criterion A /CT / CR: In stand-by mode, the EUT shall not un-intentionally transmit during the test. In transceiver mode, the EUT shall continue to successfully ping the remote laptop during the test. Criterion B / TT / TR: In stand-by mode, the EUT shall not un-intentionally transmit after the test. In transceiver mode, the EUT shall continue or resume successful pinging to the remote laptop after the test, without user intervention.
File: R86850 Page 12
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
IMMUNITY TEST DESCRIPTIONS GENERAL INFORMATION
Final tests were performed at the Elliott Laboratories Test Sites located at 41039 Boyce Road, Fremont, CA 94538-2435. Considerable engineering effort has been expended to ensure that the facilities conform to all pertinent CENELEC and IEC standards.
MEASUREMENT INSTRUMENTATION ELECTROSTATIC DISCHARGE TEST SYSTEM
An ESD generator is used for all testing. It is capable of applying electrostatic discharges in both contact discharge mode to 8 kV and air discharge mode to 16.5 kV in both positive and negative polarities in accordance with the EN 61000-4-2 basic EMC publication.
ELECTROMAGNETIC FIELD TEST SYSTEM
A signal generator and power amplifiers are used to provide a signal at the appropriate power and frequency to an antenna to obtain the required electromagnetic field at the position of the EUT in accordance with the EN 61000-4-3 basic EMC publication.
INSTRUMENT CALIBRATION
All test equipment is regularly checked to ensure that performance is maintained in accordance with the company's specifications. An appendix of this report contains the list of test equipment used and calibration information.
File: R86850 Page 13
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
IMMUNITY TEST PROCEDURES EQUIPMENT PLACEMENT
EN 61000-4-2 specifies that a tabletop EUT shall be placed on a non-conducting table 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.6 by 0.8 meter metal sheet is placed on the table and connected to the ground plane via a metal strap with two 470 kOhm resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5 millimeter thick insulating material. EN 61000-4-3 specifies that a tabletop EUT be placed on a non-conducting table 80 centimeters above a ground reference plane and that floor-mounted equipment shall be placed on an insulating support approximately 10 centimeters above a ground plane. During the EN 61000-4-3 tests, the EUT is positioned in a shielded anechoic test chamber to reduce reflections from the internal surfaces of the chamber. During the EN 61000-4-4 tests, the EUT is positioned over a ground reference plane or in a shielded chamber in conformance with this requirement.
APPLICATION OF ELECTROSTATIC DISCHARGES
The points of application of the test discharges directly to the EUT are determined after consideration of the parts of the EUT that are accessible to the operator during normal operation. Contact and air discharges are applied to the EUT, contact discharges to conducting surfaces and air-gap discharges to insulating surfaces. Contact discharges are also applied to the coupling planes to simulate nearby ESD events.
APPLICATION OF ELECTROMAGNETIC FIELD
The electromagnetic field is established at the front edge of the EUT. The frequency range is swept through the frequency range of the test using a power level necessary to obtain the required field strength at the EUT. The field is amplitude modulated using a 1 kHz or 400Hz sine wave to a depth of 80% for the swept frequency test in accordance with EN 61000-4-3. The test is repeated with each of the four sides of the EUT facing the field generating antenna. For small, portable products the test is also performed with the top and bottom sides of the EUT facing the antenna.
File: R86850 Page 14
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
Appendix A Test Equipment Calibration Data Radiated Immunity, 80 - 1,000 MHz, 19-May-11 Manufacturer Description Model Asset # Cal Due
EMCO Antenna, Biconilog Transmitting 3143 180 N/A Werlatone Directional Coupler, 80-1000
MHz, 40dB, 200W C3910 917 N/A
Rohde & Schwarz Power Sensor, 1uW-100mW, DC-18 GHz, 50ohms
NRV-Z51 1069 7/19/2011
Amplifier Research Field Probe, RF, 10 KHz - 1GHz FP4000 1430 9/9/2011 Anritsu Signal Generator, 10MHz-
20GHz 68347C 1785 11/22/2011
Rohde & Schwarz Power Meter, Dual Channel NRVD 1786 2/28/2012 Radiated Immunity, 1,000 - 2,700 MHz, 31-May-11 Manufacturer Description Model Asset # Cal Due
Rohde & Schwarz Power Sensor, 1uW-100mW, DC-18 GHz, 50ohms
NRV-Z51 1069 7/19/2011
Werlatone Directional Coupler, 1000-3000 MHz, 30dB, 100w
C6710 1532 N/A
EMCO Antenna, Horn, 1-18 GHz (SA40-Purple)
3115 1779 3/31/2012
Rohde & Schwarz Power Meter, Dual Channel NRVD 1787 12/23/2011Amplifier Research Amplifier, 25w, 0.8-4.2GHz 25S1G4AM3 1805 N/A Agilent MXG Analog Signal Generator N5181A 2146 1/26/2012 ESD, 05-Mar-12 Manufacturer Description Model Asset # Cal Due
Schaffner ESD Gun, 100pF-1500 ohm & 150pF-330 ohm tips
NSG-438 1424 9/28/2012
File: R86850 Page 15
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
File: R86850 Page 16
Appendix B Test Data Log Sheets
ELECTROMAGNETIC EMISSIONS
TEST LOG SHEETS
AND
MEASUREMENT DATA
T83198 Pages 17 - 37
EMC Test Data
Emissions Standard(s): EN 301 489-1 V1.8.1/ FCC Part 15B Class: B
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
EMC Test DataFor The
Summit Data Communications
SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg + BT 2.1)
Model
Contact: Ron Seide -
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Date of Last Test: 12/16/2011
R86850 Cover Page 17
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 21 °C
The EUT was located on a 0.5-mm thick insulating layer above a horizontal coupling plane, 80 cm above a ground reference plane.
Unless otherwise stated, ten discharges at each voltage, and polarity, were applied to each test point listed. Contact discharges were applied to coupling planes and conductive surfaces of the EUT. Air discharges were applied to any non-conductive surfaces of the EUT. The VCP was located on the table top for table top.
The determination as to the test point being a part of a conductive or non-conductive surface was based on testing the surface for conductivity using an ohmmeter.
Temperature:
Test Location: Fremont EMC Lab #2 EUT Voltage: 3.3VdcTest Engineer: M. Birgani Config Change: None
Electrostatic Discharge (EN 61000-4-2)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 3/5/2012 Config. Used: 2a
Christine Krebill
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -Contact: Ron Seide
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager:
34 %1016 mb
Summary of Results - Electrostatic Discharges
1
2
Deviations From The StandardNo deviations were made from the requirements of the standard.
A / Pass Transmit Mode
Enclosure ±4kV CD±8kV AD
±4kV CD±8kV AD
B
Enclosure ±4kV CD±8kV AD
No modifications were made to the EUT during testing
CommentsRequired Applied Required Met / Result
A / Pass Receive Mode
B
Pressure:
Run # Port Test Level
±4kV CD±8kV AD
Modifications Made During Testing
p
Performance Criteria
Relative Humidity:
R86850 ESD MSD40NBT Page 18
EMC Test Data
Christine Krebill
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -Contact: Ron Seide
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager:
Run #1: Electrostatic Discharge (Transmit Mode)
Level 1 Level 2 Level 3 Level 4 Level 1 Level 2 Level 3 Level 42 4 6 8 2 4 6 8
X X X X
X X X X
Note:
Note:
Run #2: Electrostatic Discharge (Receive Mode)
An "X" indicates that the unit continued to operate as intended. The EUT was configured to ping wirelessly to a remote hub. There were no data errors reported by the monitoring software.ND: No discharge was possible due to the lack of a discharge path to ground from the test point.HCP: Horizontal Coupling Plane. VCP: Vertical Coupling Plane
Indirect Discharges Positive Polarity Negative Polarity
ContactMode
Vertical Coupling Plane (VCP) located 10cm from the front, rear, left and right sides of the EUTHorizontal Coupling Plane (HCP) located 10cm from the front, rear, left and right sides of the EUT
Indirect Discharges Positive Polarity Negative Polarity(To Coupling Planes) (kV) (kV)
Level 1 Level 2 Level 3 Level 4 Level 1 Level 2 Level 3 Level 42 4 6 8 2 4 6 8
X X X X
X X X X
Note:
Note: ND: No discharge was possible due to the lack of a discharge path to ground from the test point.HCP: Horizontal Coupling Plane. VCP: Vertical Coupling Plane
An "X" indicates that the unit continued to operate as intended. The EUT was configured in Rx mode during testing. There were no data errors reported by the monitoring software.
ModeVertical Coupling Plane (VCP) located 10cm from the front, rear, left and right sides of the EUTHorizontal Coupling Plane (HCP) located 10cm from the front, rear, left and right sides of the EUT
(To Coupling Planes) (kV) (kV)
Contact
Indirect Discharges Positive Polarity Negative Polarity
R86850 ESD MSD40NBT Page 19
EMC Test Data
Christine Krebill
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -Contact: Ron Seide
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager:
Test Configuration Photograph #1(Electrostatic Discharge, EN 61000-4-2)
R86850 ESD MSD40NBT Page 20
EMC Test Data
Christine Krebill
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -Contact: Ron Seide
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager:
(Electrostatic Discharge, EN 61000-4-2)Test Configuration Photograph #2
R86850 ESD MSD40NBT Page 21
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 22 °C33 %
Summary of Results-Radiated Immunity
The EUT and all local support equipment were located on a turntable in an anechoic chamber. All remote support equipment was located outside the chamber. Interface cabling to the remote support equipment was routed along the floor and, where possible, passed through ferrite clamps at the exit point from the chamber.
Temperature:Rel. Humidity:
Test Location: Fremont Chamber #6 Host Unit Voltage 230V/50HzTest Engineer: Luis Cabrera Config Change: None
Radiated Immunity (EN 61000-4-3)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 5/31/2011 9:58 Config. Used: #1
Contact: Ron SeideImmunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
Summary of Results-Radiated Immunity
1
21.4GHz-2.7GHz1kHz 80% AM
3 V/m
Enclosure1.0GHz-2.7GHz1kHz 80% AM
3 V/m
Deviations From The StandardNo deviations were made from the requirements of the standard.
Modifications Made During TestingNo modifications were made to the EUT during testing
EN 301 489-1 V1.8.1 Requirements
1.4GHz-2.7GHz1kHz 80% AM
3 V/mA / Pass SDC-MSD40NBT Rx
A / Pass SDC-MSD40NBT Tx
A
Required Met / ResultRun # Port Test Level Performance Criteria CommentsRequired Applied
R86850 RI MSD40NBT 31-May-11 Page 22
EMC Test Data
Contact: Ron SeideImmunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
Run #1: Radiated Immunity, 1000-2700 MHz (EN61000-4-3)EUT configured in Rx mode on Channel 6 (2437 MHz)
2.7 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH6\2010\1-2.7 GHz (April 2010)\3 Vm\ were used:
Position B 1.3m High 1000 MHz - 2700 MHz H 3Vm.crfPosition B 1 3m High 1000 MHz 2700 MHz V 3Vm crf
Modulation: AM
Test Distance: 2m
Step Size:Dwell time:
Field Uniformity:
Depth / Deviation: 80%
1000-2700
Right Top BottomRange (MHz)Frequency Front Left Side Rear
1.5m x 1.0m
Modulation DetailsModulating Frequency: 1 kHz
Frequency: 1-2.7 GHz
Position B 1.3m High 1000 MHz - 2700 MHz V 3Vm.crf
Note:
Note:
An "X" indicates that the unit continued to operate as intended. The Eut was set to receive on CH6 No uniintentional transmissions were observed. The EUT was monitored using a near field probe and a spectrum analyser.Since the EUT was operating on CH 6 (2437MHz) The band for this channel is 2426-2448MHz and a +/-5% exclusion band (2304.7-2570.4MHz) was applied in the RI scan.
R86850 RI MSD40NBT 31-May-11 Page 23
EMC Test Data
Contact: Ron SeideImmunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
Run #2: Radiated Immunity, 1000-2700 MHz (EN61000-4-3)EUT configured in Tx mode on Channel 4 (2427 MHz)
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH6\2010\1-2.7 GHz (April 2010)\3 Vm\ were used:
Position B 1.3m High 1000 MHz - 2700 MHz H 3Vm.crfPosition B 1 3m High 1000 MHz 2700 MHz V 3Vm crf
Frequency: 1-2.7 GHzStep Size:
Dwell time:Field Uniformity: 1.5m x 1.0m
Test Distance: 2m
Modulation DetailsModulating Frequency: 1 kHz
Front Left Side Rear
Modulation: AMDepth / Deviation: 80%
1000-2700
Right Top BottomRange (MHz)Frequency
Position B 1.3m High 1000 MHz - 2700 MHz V 3Vm.crf
Note:
Note:
An "X" indicates that the unit continued to operate as intended. The EUT was setup to transmit on CH4. A signal was observed at 2427MHz CH6. The EUT was also setup to ping continuously to the AP. No loss of pings were observed during the test.Since the EUT was operating on CH 4 (2427MHz) The band for this channel is 2416-2438MHz and a +/-5% exclusion band (2295.2-2559.9MHz) was applied in the RI scan.
R86850 RI MSD40NBT 31-May-11 Page 24
EMC Test Data
Contact: Ron SeideImmunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
R86850 RI MSD40NBT 31-May-11 Page 25
EMC Test Data
Contact: Ron SeideImmunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine Krebill
R86850 RI MSD40NBT 31-May-11 Page 26
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 22 °C35 %
Summary of Results-Radiated Immunity
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Radiated Immunity (EN 61000-4-3)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 5/17/2011 17:36 Config. Used: 1
120V/60HzTest Engineer: Michael Findley Config Change: noneTest Location: Fremont Chamber #1 EUT Voltage:
The EUT and all local support equipment were located on a turntable in a semi-anechoic chamber. All remote support equipment was located on the floor inside the chamber.
Temperature:Rel. Humidity:
Summary of Results-Radiated Immunity
1
Required Applied Required Met / ResultRun # Port Test Level Performance Criteria Comments
EN 301 489-1 V1.8.1 Requirements
Enclosure
80-1000 MHz1.4GHz-2.7GHz1kHz 80% AM
3 V/m
80-1000 MHz1kHz 80% AM
3 V/mA A / Pass
Modifications Made During TestingNo modifications were made to the EUT during testing
Deviations From The StandardNo deviations were made from the requirements of the standard.
R86850 RI MSD40NBT 19-May-11 TX Page 27
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Run #1: Radiated Immunity, 80-2700 MHz (EN61000-4-3) Tx modeSDC-MSD40NBT (1x1 802.11abgn), 192.168.5.46
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH1\80-1000 MHz\80-1000 MHz (Oct 2010)\ were used:
2 5m tip of Antenna to the field 1 55m High 80 MHz 1000 MHz V 3Vm crf
80-1000 MHz
Dwell time:
Frequency:Step Size:
Top BottomFrequency Range (MHz)
80-1000
Front Left Side Rear Right
Modulation Details
Modulation: AMDepth / Deviation: 80%
Modulating Frequency: 1 kHz
Field Uniformity: 1.5m x 1.5mTest Distance: 2.5m
2.5m tip of Antenna to the field 1.55m High 80 MHz - 1000 MHz V 3Vm.crf
Pinging routine running with 100% success in all pings during test.
R86850 RI MSD40NBT 19-May-11 TX Page 28
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
R86850 RI MSD40NBT 19-May-11 TX Page 29
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
R86850 RI MSD40NBT 19-May-11 TX Page 30
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
R86850 RI MSD40NBT 19-May-11 TX Page 31
EMC Test Data
Test Specific Details
General Test Configuration
Ambient Conditions: 19.4 °C36 %
Client: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Radiated Immunity (EN 61000-4-3)
Objective: The objective of this test session is to perform final qualification testing of the EUT with respect to the specification listed above.
Date of Test: 5/19/2011 13:40 Config. Used: 1
120V/60HzTest Engineer: Conrad Chu/Vishal Config Change: NoneTest Location: Fremont Chamber #1 EUT Voltage:
The EUT and all local support equipment were located on a turntable in an anechoic chamber. All remote support equipment was located outside the chamber. Interface cabling to the remote support equipment was routed along the floor and, where possible, passed through ferrite clamps at the exit point from the chamber.
Temperature:Rel. Humidity:
Summary of Results-Radiated Immunity
1
Required Applied Required Met / ResultRun # Port Test Level Performance Criteria Comments
Modifications Made During TestingNo modifications were made to the EUT during testing
EN 301 489-1 V1.8.1 Requirements
Enclosure80-1000 MHz1kHz 80% AM
3 V/m
80-1000 MHz1kHz 80% AM
3 V/mA A / Pass
Deviations From The StandardNo deviations were made from the requirements of the standard.
R86850 RI MSD40NBT 19-May-11 RX Page 32
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Run #1: Radiated Immunity, 80-1000 MHz (EN61000-4-3)SDC-MSD40NBT (1x1 802.11abgn)EUT configured in Rx mode on Channel 7 (2442 MHz)
1 %2874 ms
LevelV/m Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz.
3 X X X X X X X X N/A N/A N/A N/A
Test files used for this run:The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH1\80 1000 MHz\80 1000 MHz (Oct 2010)\ were used:
Frequency: 80-1000 MHzStep Size:
Dwell time:Field Uniformity: 1.5m x 1.5m
Modulation: AM
Test Distance: 2.5m
Modulation DetailsModulating Frequency: 1 kHz
Depth / Deviation: 80%
Frequency Front Left Side Rear
80-1000
Right Top BottomRange (MHz)
The following calibration files from U:\EMC Stuff\RI Playback Files FT\CH1\80-1000 MHz\80-1000 MHz (Oct 2010)\ were used:2.5m tip of Antenna to the field 1.55m High 80 MHz - 1000 MHz H 3Vm.crf2.5m tip of Antenna to the field 1.55m High 80 MHz - 1000 MHz V 3Vm.crf
Note: An "X" indicates that the EUT continued to operate as intended during and after testing. The EUT was operating in standby mode and no unintentional transmissions were observed. The EUT was monitored for unintentional transmissions using a near-field probe and spectrum analyzer.
R86850 RI MSD40NBT 19-May-11 RX Page 33
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Front view
R86850 RI MSD40NBT 19-May-11 RX Page 34
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Detailed front view
R86850 RI MSD40NBT 19-May-11 RX Page 35
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Detailed rear view
R86850 RI MSD40NBT 19-May-11 RX Page 36
EMC Test DataClient: Summit Data Communications Job Number: J78403Model: SDC-WB40 and SDC-MSD40NBT (1x1 802.11abg +
BT 2.1)T-Log Number: T83198
Account Manager: Christine KrebillContact: Ron Seide
Immunity Standard(s): EN 301 489-1 V1.8.1 Environment: -
Remote spectrum analyzer used to monitor for unintentional transmissions
R86850 RI MSD40NBT 19-May-11 RX Page 37
Elliott Laboratories -- EMC Department Test Report . Report Date: March 20, 2012
End of Report
This page is intentionally blank and marks the last page of this test report.
File: R86850 Page 38