Report No.: RM990810E03 1 Report Format Version 3.0.3 EMC TEST REPORT REPORT NO. : RM990810E03 MODEL NO. : A-R0002 RECEIVED : Aug. 10, 2010 TESTED : Aug. 10 to 17, 2010 ISSUED : Aug. 20, 2010 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 34 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agencies. The test results in the report only apply to the tested sample.

Upload: buinhu

Post on 28-Apr-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 1 Report Format Version 3.0.3

EMC TEST REPORT REPORT NO. : RM990810E03

MODEL NO. : A-R0002

RECEIVED : Aug. 10, 2010

TESTED : Aug. 10 to 17, 2010

ISSUED : Aug. 20, 2010

APPLICANT : LOGITECH FAR EAST LTD.

ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan

LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan

TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan

TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan

This test report consists of 34 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agencies. The test results in the report only apply to the tested sample.

Page 2: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 2 Report Format Version 3.0.3

Table of Contents 1 CERTIFICATION .................................................................................................................. 4 2 SUMMARY OF TEST RESULTS........................................................................................... 5 2.1 MEASUREMENT UNCERTAINTY ........................................................................................ 5 3 GENERAL INFORMATION................................................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT...................................................................................... 6 3.2 GENERAL DESCRIPTION OF TEST MODE ........................................................................ 7 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS........................................................ 8 3.4 DESCRIPTION OF SUPPORT UNITS.................................................................................. 9 3.1 CONFIGURATION OF SYSTEM UNDER TEST ................................................................... 9 4 EMISSION TEST.................................................................................................................11 4.1 CONDUCTED EMISSION MEASUREMENT .......................................................................11 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT .....................................................11 4.1.2 TEST INSTRUMENTS.........................................................................................................11 4.1.3 TEST PROCEDURE........................................................................................................... 12 4.1.4 DEVIATION FROM TEST STANDARD ............................................................................... 12 4.1.5 TEST SETUP ..................................................................................................................... 12 4.1.6 EUT OPERATING CONDITIONS........................................................................................ 13 4.1.7 TEST RESULTS................................................................................................................. 14 5 IMMUNITY TEST................................................................................................................ 16 5.1 GENERAL DESCRIPTION ................................................................................................. 16 5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION .................................................... 17 5.3 EUT OPERATING CONDITION.......................................................................................... 19 5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) .................................................. 20 5.4.1 TEST SPECIFICATION ...................................................................................................... 20 5.4.2 TEST INSTRUMENTS........................................................................................................ 20 5.4.3 TEST PROCEDURE........................................................................................................... 21 5.4.4 DEVIATION FROM TEST STANDARD ............................................................................... 21 5.4.5 TEST SETUP ..................................................................................................................... 22 5.4.6 TEST RESULTS (MODE 1) ................................................................................................ 23 5.4.7 TEST RESULTS (MODE 2) ................................................................................................ 25 5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS) .. 27 5.5.1 TEST SPECIFICATION ...................................................................................................... 27 5.5.2 TEST INSTRUMENTS........................................................................................................ 27 5.5.3 TEST PROCEDURE........................................................................................................... 28 5.5.4 DEVIATION FROM TEST STANDARD ............................................................................... 28 5.5.5 TEST SETUP ..................................................................................................................... 28 5.5.6 TEST RESULTS (MDOE 1) ................................................................................................ 29 5.5.7 TEST RESULTS (MDOE 2) ................................................................................................ 30 6 PHOTOGRAPHS OF THE TEST CONFIGURATION .......................................................... 31

Page 3: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 3 Report Format Version 3.0.3

7 APPENDIX - INFORMATION ON THE TESTING LABORATORIES .................................... 34

Page 4: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 4 Report Format Version 3.0.3

1 CERTIFICATION

PRODUCT: Logitech Wireless Headset F540

BRAND NAME: Logitech

MODEL NO.: A-R0002

APPLICANT: LOGITECH FAR EAST LTD.

TESTED: Aug. 10 to 17, 2010

TEST SAMPLE: R&D SAMPLE STANDARDS: EN 301 489-1 V1.8.1 (2008-04)

EN 301 489-3 V1.4.1 (2002-08) EN 55022:2006+A1:2007, Class B EN 61000-3-2:2006 (Not Applicable) EN 61000-3-3:2008 (Not Applicable) EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008 EN 61000-4-4:2004a1:2010 (Not Applicable) EN 61000-4-5:2006 (Not Applicable) EN 61000-4-6:2009 (Not Applicable) EN 61000-4-11:2004 (Not Applicable)

The above equipment (Model: A-R0002) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report.

PREPARED BY :

, DATE: Aug. 20, 2010 ( Sunny Wen, Specialist )

TECHNICAL ACCEPTANCE

:

, DATE: Aug. 20, 2010 ( Ray Yeh, Deputy Manager )

APPROVED BY :

, DATE: Aug. 20, 2010 ( May Chen, Deputy Manager )

Page 5: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 5 Report Format Version 3.0.3

2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications:

EMISSION Standard Test Type Result Remarks

Conducted Test PASS Meets Class B Limit Minimum passing margin is -2.95dB at 9.902MHz

Telecommunication Ports Conducted Test NA Not Applicable

EN 55022:2006 +A1:2007, Class B

Radiated Test NA Not Applicable

EN 61000-3-2:2006 Harmonic current emissions NA Not Applicable

EN 61000-3-3:2008 Voltage fluctuations & flicker NA Not Applicable

IMMUNITY

Standard Test Type Result Remarks

EN 61000-4-2:2009 Electrostatic discharge immunity test PASS Meets the requirements of

Performance Criterion B

EN 61000-4-3:2006 +A1:2008

Radiated, radio-frequency, electromagnetic field immunity test

PASS Meets the requirements of Performance Criterion A

EN 61000-4-4:2004 +a1:2010

Electrical fast transient / burst immunity test. NA Not Applicable

EN 61000-4-5:2006 Surge immunity test NA Not Applicable

EN 61000-4-6:2009 Immunity to conducted disturbances, induced by radio-frequency fields

NA Not Applicable

EN 61000-4-11:2004 Voltage dips, short interruptions and voltage variations immunity tests

NA Not Applicable

2.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Measurement Value Conducted emissions 2.45 dB

Page 6: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 6 Report Format Version 3.0.3

3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT

PRODUCT Logitech Wireless Headset F540 MODEL NO. A-R0002

POWER SUPPLY DC 6V from host equipment or DC 3.7V battery MODULATION TYPE π/4-DQPSK OPERATING FREQUENCY 2405MHz ~ 2477MHz

NUMBER OF CHANNEL 37

ANTENNA TYPE Wire monopole, ¼ wave (Antenna Gain : 7.7dBi)

DATA CABLE XBox 360 voice cable (Shielded, 1.2m) Mini-USB PS3 voice cable (Shielded, 1.8m)

I/O PORT USB port x 1 voice audio port x 1

ASSOCIATED DEVICES Battery

NOTE:

1. The EUT must be supplied with a battery as following table: Brand Li-ion Model No. L-LY11 Rating 3.7V, 600mAh

2. The EUT was pre-tested under the following modes:

Test Mode Description Mode A Y-Z Plane - Host system mode Mode B X-Y Plane - Host system mode Mode C X-Z Plane - Host system mode Mode D Y-Z Plane - Battery mode Mode E X-Y Plane - Battery mode Mode F X-Z Plane - Battery mode The worse radiated emission was found in Mode B. Therefore only the test data of the modes were recorded in this report.

3. The above EUT information was declared by the manufacturer and for more detailed features description, please refer to the manufacturer's specifications or User's Manual.

Page 7: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 7 Report Format Version 3.0.3

3.2 GENERAL DESCRIPTION OF TEST MODE

The EUT was tested under following test modes:

Conducted test Test Mode Description Mode 1 X-Y Plane - Host system mode Immunity test Test Mode Description Mode 1 X-Y Plane - Host system mode Mode 2 X-Y Plane - Battery mode

Page 8: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 8 Report Format Version 3.0.3

3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS The EUT is a RF product. According to the specifications of the manufacturer, it must comply with the requirements of the following standards:

EN 301 489-1 V1.8.1 (2008-04), EN 301 489-3 V1.4.1 (2002-08) Emission tests: EN 55022:2006+A1:2007, Class B EN 61000-3-2:2006 (Not Applicable) EN 61000-3-3:2008 (Not Applicable) Immunity tests: EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008 EN 61000-4-4:2004+a1:2010 (Not Applicable) EN 61000-4-5:2006 (Not Applicable) EN 61000-4-6:2009 (Not Applicable) EN 61000-4-11:2004 (Not Applicable)

All test items have been performed and recorded as per the above standards.

Page 9: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 9 Report Format Version 3.0.3

3.4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. No. Product Brand Model No. Serial No. FCC ID

1 TV MONITOR Panasonic TH-L26K10W 9540684 NA 2 PLAYSTATION. 3 SONY CECHB07 27430232-9740084 FCC DoC 3 XBOX Microsoft XBOX 360 NA FCC DoC

4 Logitech Wireless Headset F540 (BOX)

Logitech A-E0001 NA NA

5 iPod APPLE A1199 YM712NGUVQ5 FCC DoC No. Signal cable description 1 NA 2 1.8 m Video cable. 3 1.8 m Video cable. / 1.8 m & 1.2 m Audio cable. 4 1.9 m Audio cable. / 1.2 m USB cable. 5 1.0 m shielded cable, terminated with USB connector, w/o core.

NOTE: All power cords of the above support units are non-shielded (1.8m). 3.1 CONFIGURATION OF SYSTEM UNDER TEST For Conducted / Radiated / Immunity test mode 1:

Adapter (on test table)

2. PLAYSTATION. 3 (BOX)

2. PLAYSTATION. 3 (Rocker)

3. XBOX (BOX)

3. XBOX (Rocker) 5. iPod

Audio cable (1.2m)

USB cable (1.8m) Wireless

EUT

1. TV MONITOR 4. Logitech Wireless Headset F540 (BOX)

Page 10: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 10 Report Format Version 3.0.3

For Immunity test mode 2:

TEST TABLE

Adapter (on the table)

2. PLAYSTATION. 3 (BOX)

2. PLAYSTATION. 3 (Rocker)

3. XBOX (BOX)

3. XBOX (Rocker) 5. iPod

Wireless

1. TV MONITOR 4. Logitech Wireless Headset F540 (BOX)

EUT

Page 11: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 11 Report Format Version 3.0.3

4 EMISSION TEST

4.1 CONDUCTED EMISSION MEASUREMENT

4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT TEST STANDARD: EN 55022

Class A (dBuV) Class B (dBuV) FREQUENCY (MHz) Quasi-peak Average Quasi-peak Average 0.15 - 0.5 79 66 66 - 56 56 - 46 0.50 - 5.0 73 60 56 46 5.0 - 30.0 73 60 60 50

NOTE: (1) The lower limit shall apply at the transition frequencies.

(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

(3) All emanations from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above.

4.1.2 TEST INSTRUMENTS

DESCRIPTION & MANUFACTURER

MODEL NO. SERIAL NO. CALIBRATED DATE

CALIBRATED UNTIL

Test Receiver ESCS 30 100375 Mar. 09, 2010 Mar. 08, 2011 Line-Impedance Stabilization Network (for EUT)

NSLK 8127 8127-522 Sep. 23, 2009 Sep. 22, 2010

Line-Impedance Stabilization Network (for Peripheral)

ESH3-Z5 848773/004 Oct. 26, 2009 Oct. 25, 2010

RF Cable (JYEBAO) 5DFB COBCAB-001 Nov. 24, 2009 Nov. 23, 2010 50 ohms Terminator 50 3 Oct. 28, 2009 Oct. 27, 2010

Software BV ADT_Cond_V7.3.7

NA NA NA

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are

traceable to NML/ROC and NIST/USA. 2. The test was performed in Shielded Room No. C. 3 The VCCI Con C Registration No. is C-3611.

Page 12: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 12 Report Format Version 3.0.3

4.1.3 TEST PROCEDURE a. The EUT was placed 0.4 meters from the conducting wall of the shielded room

with EUT being connected to the power mains through a line impedance stabilization network (LISN). Other support units were connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.

b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.

c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels over 10dB under the prescribed limits could not be reported.

4.1.4 DEVIATION FROM TEST STANDARD No deviation

4.1.5 TEST SETUP

N o te : 1 .S u p p o rt u n its w e re c o n n e cte d to s ec o n d L IS N .

2 .B o th o f L IS N s (A M N ) a re 8 0 c m fro m E U T a n d a t le a s t 80

fro m o th e r u n its an d o th e r m eta l p la n e s

Ve rtic a l R e fe re n c e

G ro u n d P lan e

4 0 c m

8 0c m

Te st R e c e iv e r

H o riz o n ta l R efe re n c eG ro u n d P la n e

E U T

L IS N

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.

Page 13: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 13 Report Format Version 3.0.3

4.1.6 EUT OPERATING CONDITIONS

1. Place the EUT on testing table.

2. The support unit 4 (Logitech Wireless Headset F540 (BOX)) runs test program to enable EUT under transmission/receiving condition continuously via one USB cable and wireless transmission.

3. The support unit 3 (XBOX) sends audio messages to EUT via support unit 1 (TV MONITOR) & support unit 4 (Logitech Wireless Headset F540 (BOX)) by audio cables and wireless.

4. The EUT sends audio messages to support unit 1 (TV MONITOR) via support 3 (XBOX) by audio cables.

Page 14: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 14 Report Format Version 3.0.3

4.1.7 TEST RESULTS

TEST MODE Mode 1 PHASE Line (L)

INPUT POWER (SYSTEM) 230Vac, 50 Hz 6dB BANDWIDTH 9 kHz

ENVIRONMENTAL CONDITIONS

25 deg. C, 50 % RH, 1014 hPa TESTED BY Eric Lee

Freq. Corr. Reading Value Emission Level Limit Margin

No Factor [dB (uV)] [dB (uV)] [dB (uV)] (dB) [MHz] (dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 0.185 0.05 51.00 - 51.05 - 64.25 54.25 -13.20 - 2 0.423 0.06 52.25 39.98 52.31 40.04 57.38 47.38 -5.07 -7.34 3 0.759 0.08 49.49 39.96 49.57 40.04 56.00 46.00 -6.43 -5.96 4 0.822 0.08 47.15 38.36 47.23 38.44 56.00 46.00 -8.77 -7.56 5 1.609 0.11 45.10 - 45.21 - 56.00 46.00 -10.79 - 6 1.844 0.12 44.36 - 44.48 - 56.00 46.00 -11.52 - 7 2.152 0.13 51.57 42.18 51.70 42.31 56.00 46.00 -4.30 -3.69 8 9.902 0.35 50.59 46.70 50.94 47.05 60.00 50.00 -9.06 -2.95

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value.

Page 15: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 15 Report Format Version 3.0.3

TEST MODE Mode 1 PHASE Neutral (N)

INPUT POWER (SYSTEM) 230Vac, 50 Hz 6dB BANDWIDTH 9 kHz

ENVIRONMENTAL CONDITIONS

25 deg. C, 50 % RH, 1014 hPa TESTED BY Eric Lee

Freq. Corr. Reading Value Emission Level Limit Margin

No Factor [dB (uV)] [dB (uV)] [dB (uV)] (dB) [MHz] (dB) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 1 0.162 0.06 53.76 - 53.82 - 65.38 55.38 -11.55 - 2 0.232 0.06 50.31 - 50.37 - 62.38 52.38 -12.01 - 3 0.420 0.07 42.83 - 42.90 - 57.46 47.46 -14.56 - 4 0.752 0.09 40.16 - 40.25 - 56.00 46.00 -15.75 - 5 0.818 0.09 43.02 - 43.11 - 56.00 46.00 -12.89 - 6 1.609 0.12 43.02 - 43.14 - 56.00 46.00 -12.86 - 7 1.699 0.13 41.41 - 41.54 - 56.00 46.00 -14.46 - 8 2.262 0.15 42.71 - 42.86 - 56.00 46.00 -13.14 - 9 10.063 0.36 33.05 - 33.41 - 60.00 50.00 -26.59 -

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Emission level - Limit value 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value.

Page 16: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 16 Report Format Version 3.0.3

5 IMMUNITY TEST

5.1 GENERAL DESCRIPTION

Product Standard: EN 301 489-1 (2008-04), EN 301 489-3 (2002-08) EN 61000-4-2 Electrostatic Discharge – ESD:

8kV air discharge, 4kV Contact discharge, Performance Criterion B

EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test – RS: 80-1000 MHz, 1400-2700 MHz, 3V/m, 80% AM (1kHz), Performance Criterion A

EN 61000-4-4 Electrical Fast Transient/Burst - EFT, Power line: 1kV, Signal line: 0.5kV, Performance Criterion B

EN 61000-4-5 Surge Immunity Test: 1.2/50 us Open Circuit Voltage, 8 /20 us Short Circuit Current, line to line – 0.5 kV, line to earth - 1kV, Performance Criterion B

EN 61000-4-6 Conducted Radio Frequency Disturbances Test – CS: 0.15-80 MHz, 3Vrms, 80% AM, 1kHz, Performance Criterion A

Basic Standard, Specification, and Performance Criteria:

EN 61000-4-11 Voltage Dips: i) 0% residual for 0.5 cycle,

Performance Criterion B ii) 0% residual for 1 cycle,

Performance Criterion B iii) 70% residual for 25 cycle,

Performance Criterion B Voltage Interruptions: i) 0% residual for 250 cycle,

Performance Criterion B is required for EUT with battery back-up, Performance Criterion C is required for EUT without battery back-up.

Page 17: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 17 Report Format Version 3.0.3

5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION

The Requirement of Performance Criteria

1 Performance criteria for continuous phenomena applied to transmitters (CT)

Criterion A of the applicable class shall apply

2 Performance criteria for transient phenomena applied to transmitters (TT)

Criterion B of the applicable class shall apply

3 Performance criteria for continuous phenomena applied to receivers (CR)

Criterion A of the applicable class shall apply

4 Performance criteria for transient phenomena applied to receivers (TR)

Criterion B of the applicable class shall apply

Page 18: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 18 Report Format Version 3.0.3

The phenomena allowed during and after test in each criterion are clearly stated in the following table:

Class 1 SRD equipment Criteria During test After test

A

Operate as intended. No loss of function. For equipment type II the minimum performance shall be 12dB SINAD No unintentional responses

Operate as intended. For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions

B May be loss of function (one or more) No unintentional responses

Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions

Class 2 SRD equipment Criteria During test After test

A

Operate as intended. No loss of function. For equipment type II the minimum performance shall be 6dB SINAD NO UNINTENTIONAL RESPONSES

Operate as intended. For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions

B MAY BE LOSS OF FUNCTION (ONE OR MORE) No unintentional responses

Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions

Class 3 SRD equipment Criteria During test After test

A and B MAY BE LOSS OF FUNCTION (ONE OR MORE) No unintentional responses

Operate as intended, for equipment type II the communication link may be lost, but shall be recoverable by user No degradation of performance Lost functions shall be self-recoverable

NOTE: This device belongs to Type I, class 3 SRD equipment.

Page 19: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 19 Report Format Version 3.0.3

5.3 EUT OPERATING CONDITION For test mode 1:

5. Place the EUT on testing table.

6. The support unit 4 (Logitech Wireless Headset F540 (BOX)) runs test program to enable EUT under transmission/receiving condition continuously via one USB cable and wireless transmission.

7. The support unit 3 (XBOX) sends audio messages to EUT via support unit 1 (TV MONITOR) & support unit 4 (Logitech Wireless Headset F540 (BOX)) by audio cables and wireless.

8. The EUT sends audio messages to support unit 1 (TV MONITOR) via support 3 (XBOX) by audio cables.

For test mode 2:

1. Place the EUT on testing table.

2. The support unit 4 (Logitech Wireless Headset F540 (BOX)) runs test program to enable EUT under transmission/receiving condition continuously via one USB cable and wireless transmission.

3. The support unit 5 (iPod) sends audio messages to EUT via support unit 4 (Logitech Wireless Headset F540 (BOX)) by wireless.

Page 20: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 20 Report Format Version 3.0.3

5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)

5.4.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-2 Discharge Impedance: 330 ohm / 150 pF Discharge Voltage: Air Discharge – 2, 4, 8kV (Direct)

Contact Discharge – 2, 4kV (Indirect) Polarity: Positive & Negative Number of Discharge: Minimum 20 times at each test point Discharge Mode: Single Discharge Discharge Period: 1 second minimum

5.4.2 TEST INSTRUMENTS

DESCRIPTION & MANUFACTURER

MODEL NO. SERIAL NO. CALIBRATED DATE

CALIBRATED UNTIL

NoiseKen, ESD Simulator ESS-100L(A) 0189C01491 Aug. 03, 2010 Aug. 02, 2011

Key Tek, ESD Simulator MZ-15/EC 9906323 June 11, 2010 June 10, 2011 Key Tek, ESD Simulator MZ-15/EC 0912389 Jan. 06, 2010 Jan. 05, 2011 NoiseKen, ESD Simulator ESS-2002 ESS0625212/244 May 07, 2010 May 08, 2011

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA.

2. The test was performed in ESD room A.

Page 21: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 21 Report Format Version 3.0.3

5.4.3 TEST PROCEDURE

a. Electrostatic discharges were applied only to those points and surfaces of the EUT that are accessible to users during normal operation.

b. The test was performed with at least ten single discharges on the pre-selected points in the most sensitive polarity.

c. The time interval between two successive single discharges was at least 1 second.

d. The ESD generator was held perpendicularly to the surface to which the discharge was applied and the return cable was at least 0.2 meters from the EUT.

e. Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator penetrating the coating and contacting the conducting substrate.

f. Air discharges were applied with the round discharge tip of the discharge electrode approaching the EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD generator was removed from the EUT and re-triggered for a new single discharge. The test was repeated until all discharges were complete.

g. At least ten single discharges (in the most sensitive polarity) were applied to the Horizontal Coupling Plane at points on each side of the EUT. The ESD generator was positioned at a distance of 0.1 meters from the EUT with the discharge electrode touching the HCP.

h. At least ten single discharges (in the most sensitive polarity) were applied to the center of one vertical edge of the Vertical Coupling Plane in sufficiently different positions that the four faces of the EUT were completely illuminated. The VCP (dimensions 0.5m x 0.5m) was placed vertically to and 0.1 meters from the EUT.

5.4.4 DEVIATION FROM TEST STANDARD No deviation As per client requests, the following discharge levels were also applied: Contact Discharge – 6, 8kV for indirect contact discharge. Air Discharge – 10, 12, 15kV for direct air discharge.

Page 22: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 22 Report Format Version 3.0.3

5.4.5 TEST SETUP

PS

EUT

Verticalcoupling plane

0.5mm Isolation Support

ESDGenerator

NearestWall Horizontal

coupling plane

Reference Ground Plane

0.1m1m

470kX4

80cm

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration.

NOTE:

TABLE-TOP EQUIPMENT The configuration consisted of a wooden table 0.8 meters high standing on the Ground Reference Plane. The GRP consisted of a sheet of aluminum at least 0.25mm thick, and 2.5 meters square connected to the protective grounding system. A Horizontal Coupling Plane (1.6m x 0.8m) was placed on the table and attached to the GRP by means of a cable with 940kΩ total impedance. The equipment under test, was installed in a representative system as described in section 7 of EN 61000-4-2, and its cables were placed on the HCP and isolated by an insulating support of 0.5mm thickness. A distance of 1-meter minimum was provided between the EUT and the walls of the laboratory and any other metallic structure.

Page 23: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 23 Report Format Version 3.0.3

5.4.6 TEST RESULTS (MODE 1)

MODE Mode 1 INPUT POWER (SYSTEM) 120Vac, 60Hz

ENVIRONMENTAL CONDITIONS (Start of Test)

25 deg. C, 45 % RH, 1014 hPa

ENVIRONMENTAL CONDITIONS (End of Test)

25 deg. C, 45 % RH, 1014 hPa

TESTED BY : Barry Lee

TEST RESULTS OF DIRECT APPLICATION

Discharge Level (kV)

Polarity (+/-) Test Point Contact

Discharge Air Discharge Performance Criterion

2, 4 +/- 1 NA NOTE (1) A 8 +/- 1 NA NOTE (2) B

2, 4, 8 +/- 1 ~ 3 NA NOTE (1) A

No conductive surfaces found, therefore no contact discharge was executed. Description of test point: Please refer to following page for representative mark only.

TEST RESULTS OF INDIRECT APPLICATION

Discharge Level (kV)

Polarity (+/-) Test Point

Horizontal Coupling

Plane

Vertical Coupling

Plane

Performance Criterion

2, 4 +/- 1 ~ 4 NOTE (2) NOTE (2) B

Description of test point: 1. Front side 2. Right side 3. Left side 4. Rear side

NOTE: (1) There was no change compared with the initial operation during the

test. (2) There were noises found via speaker during the test, but could be

self-recoverable after the test. (2) The cursor function held temporarily, but could be self-recoverable after the test.

Page 24: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 24 Report Format Version 3.0.3

DESCRIPTION OF TEST POINT (MODE 1)

1

3

2

Page 25: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 25 Report Format Version 3.0.3

5.4.7 TEST RESULTS (MODE 2)

MODE Mode 2 INPUT POWER DC 3.7V from battery

ENVIRONMENTAL CONDITIONS (Start of Test)

25 deg. C, 45 % RH, 1014 hPa

ENVIRONMENTAL CONDITIONS (End of Test)

25 deg. C, 45 % RH, 1014 hPa

TESTED BY : Barry Lee

TEST RESULTS OF DIRECT APPLICATION

Discharge Level (kV)

Polarity (+/-) Test Point Contact

Discharge Air Discharge Performance Criterion

2, 4, 8 +/- 1 ~ 3 NA NOTE (1) A

No conductive surfaces found, therefore no contact discharge was executed. Description of test point: Please refer to following page for representative mark only.

TEST RESULTS OF INDIRECT APPLICATION

Discharge Level (kV)

Polarity (+/-) Test Point

Horizontal Coupling

Plane

Vertical Coupling

Plane

Performance Criterion

2, 4 +/- 1 ~ 4 NOTE (2) NOTE (2) B

Description of test point: 1. Front side 2. Right side 3. Left side 4. Rear side

NOTE: (1) There was no change compared with the initial operation during the

test. (2) There were noises found via speaker during the test, but could be

self-recoverable after the test. (2) The cursor function held temporarily, but could be self-recoverable after the test.

Page 26: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 26 Report Format Version 3.0.3

DESCRIPTION OF TEST POINT (MODE 2)

1

3

2

Page 27: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 27 Report Format Version 3.0.3

5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS)

5.5.1 TEST SPECIFICATION

Basic Standard: EN 61000-4-3 Frequency Range: 80 MHz - 1000 MHz

1400 MHz - 2700 MHz Field Strength: 3 V/m Modulation: 1kHz Sine Wave, 80%, AM Modulation Frequency Step: 1 % of momentary frequency Polarity of Antenna: Horizontal and Vertical Antenna Height: 1.5m Dwell Time: 3 seconds

5.5.2 TEST INSTRUMENTS

DESCRIPTION & MANUFACTURER

MODEL NO. SERIAL NO. CALIBRATED DATE

CALIBRATED UNTIL

AR Power Amplifier 150W1000M3 311567 NA NA AR Power Amplifier 60S1G3M1 306171 NA NA AR LOG ANTENNA AT5080ANT 309740 NA NA BOONTON RF Voltage Meter

4232A 93801 Dec. 19, 2009 Dec. 18, 2010

R&S Signal Generator SML03 101159 Dec. 28, 2009 Dec. 27, 2010 Electric Field Probe FP6001 308178 Dec. 04, 2009 Dec. 03, 2010 ADT RS Test Workbench(Software)

ADT_RS_V7.5 NA NA NA

NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA.

2. The test was performed in Chamber Room No. B. 3. The transmit antenna was located at a distance of 2.0 meters from the EUT.

Page 28: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 28 Report Format Version 3.0.3

5.5.3 TEST PROCEDURE

The test procedure was in accordance with EN 61000-4-3

a. The testing was performed in a fully-anechoic chamber.

b. The frequency range is swept from 80 MHz to 1000 MHz, 1400 MHz to 2700 MHz with the signal 80% amplitude modulated with a 1kHz sine wave.

c. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond, but shall in no case be less than 0,5s.

d. The field strength level was 3V/m.

e. The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides.

5.5.4 DEVIATION FROM TEST STANDARD No deviation

5.5.5 TEST SETUP

For the actual test configuration, please refer to the related item – Photographs of the Test Configuration. NOTE: TABLETOP EQUIPMENT The EUT installed in a representative system as described in section 7 of EN 61000-4-3 was placed on a non-conductive table 0.8 meters in height. The system under test was connected to the power and signal wire according to relevant installation instructions.

EUT

RF Amplifier RF Generator and control system

Monitoring system

Page 29: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 29 Report Format Version 3.0.3

5.5.6 TEST RESULTS (MDOE 1)

MODE Mode 1 INPUT POWER (SYSTEM) 230Vac, 50Hz

ENVIRONMENTAL CONDITIONS (START OF TEST)

25 deg. C, 45 % RH, 1014 hPa

ENVIRONMENTAL CONDITIONS (END OF TEST)

25 deg. C, 45 % RH, 1014 hPa

TESTED BY: Anderson Chen

Frequency (MHz)

Result Polarity Azimuth Field

Strength

(V/m)

Obser- vation

Performance Criterion

80 -1000 PASS V&H 0 3

80 -1000 PASS V&H 90 3

80 -1000 PASS V&H 180 3

80 -1000 PASS V&H 270 3

1400 -2700 PASS V&H 0 3

1400 -2700 PASS V&H 90 3

1400 -2700 PASS V&H 180 3

1400 -2700 PASS V&H 270 3

NOTE A

NOTE: There was no change compared with initial operation during the test.

Page 30: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 30 Report Format Version 3.0.3

5.5.7 TEST RESULTS (MDOE 2) MODE Mode 2 INPUT POWER DC 3.7V from battery

ENVIRONMENTAL CONDITIONS (START OF TEST)

25 deg. C, 45 % RH, 1014 hPa

ENVIRONMENTAL CONDITIONS (END OF TEST)

25 deg. C, 45 % RH, 1014 hPa

TESTED BY: Anderson Chen

Frequency (MHz)

Result Polarity Azimuth Field

Strength

(V/m)

Obser- vation

Performance Criterion

80 -1000 PASS V&H 0 3

80 -1000 PASS V&H 90 3

80 -1000 PASS V&H 180 3

80 -1000 PASS V&H 270 3

1400 -2700 PASS V&H 0 3

1400 -2700 PASS V&H 90 3

1400 -2700 PASS V&H 180 3

1400 -2700 PASS V&H 270 3

NOTE A

NOTE: There was no change compared with initial operation during the test.

Page 31: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 31 Report Format Version 3.0.3

6 PHOTOGRAPHS OF THE TEST CONFIGURATION

CONDUCTED EMISSION TEST

Page 32: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 32 Report Format Version 3.0.3

ESD TEST (MODE 1)

ESD TEST (MODE 2)

Page 33: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 33 Report Format Version 3.0.3

RS TEST (MODE 1)

RS TEST (MODE 2)

Page 34: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Report No.: RM990810E03 34 Report Format Version 3.0.3

7 APPENDIX - INFORMATION ON THE TESTING LABORATORIES

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and approved according to ISO/IEC 17025:

Copies of accreditation certificates of our laboratories obtained from approval agencies can be downloaded from our web site: www.adt.com.tw/index.5/phtml. If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab: Tel: 886-2-26052180 Fax: 886-2-26052943

Hsin Chu EMC/RF Lab: Tel: 886-3-5935343 Fax: 886-3-5935342

Hwa Ya EMC/RF/Safety/Telecom Lab: Tel: 886-3-3183232 Fax: 886-3-3185050

Email: [email protected] Web Site: www.adt.com.tw

The address and road map of all our labs can be found in our web site also. --- END ---

Page 35: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 1

CONSTRUCTION PHOTOS OF EUT

Page 36: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 2

Page 37: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 3

Page 38: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 4

Page 39: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 5

Page 40: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 6

Page 41: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 7

Page 42: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 8

Page 43: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 9

Page 44: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 10

Page 45: EMC TEST REPORT - Logitech EN301489... · EMC TEST REPORT REPORT NO ... Taoyuan Branch Hsin Chu Laboratory LAB LOCATION : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin

Page 11