emc test report of.pdf

Upload: has

Post on 02-Jun-2018

266 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 EMC TEST REPORT OF.PDF

    1/42

    01 050118 B. Gorini G.Mangili

    ED DATE CHANGE NOTE APPRAISAL AUTHORITY ORIGINATOR

    1AA000140004(97

    11)A4

    OND

    ED 01

    3AL 36420 0000 QZZZA 1/2

    Allrightsreserved.

    Passingonandco

    pyingofthis

    document,useandcommunicationofitscontents,not

    permittedwithoutwrittenauthorization

    fromA

    lcatel

    EMC TEST REPORT OF

    1660 SM Rel.5.2B

    TEST REPORT

    TABLE OF CONTENTS

    TEST REPORT 1

    1 UPGRADES 2

    2 WARNING 2

  • 8/10/2019 EMC TEST REPORT OF.PDF

    2/42

    2/2

    ED 01

    OND 3AL 36420 0000 QZZZA

    Allrightsreserved.

    Passingonandcopy

    ingofthis

    document,useandcommunicationofitscontents,not

    permittedwithoutwrittenauthorizationfromA

    lcatel

    1AA000140004(9711)A4

    1 UPGRADES

    EDITION DATE CHANGE NOTE

    01 18/01/2005 First edition

    2 WARNING

    This page and the previous one are not part of the original document. They have been added to give aformal structure to the document provided by the EMC Laboratory.

    The original document starts on the next page.

    END OF DOCUMENT

  • 8/10/2019 EMC TEST REPORT OF.PDF

    3/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Alcatel Italia S.p.A. Laboratory accredited according to IEC/ISO17025

    Via Trento, 30 - 20059 Vimercate (Mi) by MINISTERO DELLE COMUNICAZIONI

    Ph. +39 (039) 686.4325 Accreditation certificates No. 028 / 029 / 069

    Fax +39 (039) 686.3189 Competent Body for the EMC directive 89/336

    Conformity Assessment Body for the EU/USAMRA in the EMC sector

    EMC TEST REPORT OF1660SM Rel.5.2B

    Applicant:

    G. Festa Low Capacity Laboratory

    (Centre 4108)

    Alcatel

    Via Trento 30 20059 Vimercate

    Total pages of the report: 40

    Test reference number :

    N of original distributed: 2

    This report may be reproduced in full or partially only with the written consent of the Laboratory.

    The test results in this report apply only to the sample(s) tested.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    4/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    2/31

    SUMMARY

    This report is concerning the EMC characteristics of the equipment 1660SM Rel.5.2B, cod. 3AL 81407 ACAA

    manufactured by Alcatel.

    The equipment has been tested with reference to the following harmonised standard to demonstrate the

    conformity to the protection requirements of the council directive 89/336 EEC, according to the article 10.1:

    - ETSI EN 300386 V1.3.2 (Ed. 05/2003) for transmission equipment, location "TELECOMMUNICATION

    CENTRES".

    Additional measurements have been performed, as requested by the customer, in accordance to the following

    voluntary requirements:

    - CISPR/I/105/CDV (ed. 2004)

    - CISPR/I/106/CDV (ed. 2004)

    for radiated emission above 1GHz (Frequency range test: 1 - 18 GHz).

    - ETSI ES 201468 v1.2.1 (ed. 09/2002):

    location " TELECOMMUNICATION CENTRES " "LEVEL 2" for immunity requirements.

    The test performed, the reference basic standards and the results are summarised in the paragraph 7.

    (Request of activity N469/02).

  • 8/10/2019 EMC TEST REPORT OF.PDF

    5/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    3/31

    CONTENTS

    1 SCOPE ........................................................................................................................................................................................... 5

    2 CONCLUSIONS........................................................................................................................................................................... 5

    3 EQUIPMENT UNDER TEST (EUT)......................................................................................................................................... 6

    3.1 IDENTIFICATION OF THE EUT...................................................................................................................................................... 6

    3.2 DESCRIPTION OF THE EUT.......................................................................................................................................................... 6

    3.3 EUT CONFIGURATION ................................................................................................................................................................ 6

    3.4 CARD PRE-SETTING STRAPS........................................................................................................................................................ 7

    3.5 MODIFICATIONS INCORPORATED IN THE EUT (NOT IN THE PRODUCT DOCUMENTATION).......................................................... 7

    3.6 SUPPORT EQUIPMENT ................................................................................................................................................................. 7

    4 REFERENCE STANDARDS...................................................................................................................................................... 8

    5 EMISSION TESTS.................................................................................................................................................................... 10

    5.1 RADIATED EMISSIONS TESTS (PLANE WAVE)........................................................................................................... 10

    5.1.1 Test specification, methods and procedures.................................................................................................................. 10

    5.1.2 Test configuration.......................................................................................................................................................... 105.1.2.1 Environmental conditions: ........................................................................................................................................................ 10

    5.1.2.2 Operating voltage: ..................................................................................................................................................................... 10

    5.1.2.3 Operating mode: ........................................................................................................................................................................ 10

    5.1.2.4 Line attenuation: ........................................................................................................................................................................ 10

    5.1.2.5 Support equipment: ................................................................................................................................................................... 11

    5.1.2.6 Cable lengths: ............................................................................................................................................................................ 11

    5.1.3 Tests results .................................................................................................................................................................... 11

    5.2 RADIATED EMISSIONS TESTS (PLANE WAVE) 1 - 18 GHZ ...................................................................................... 12

    5.2.1 Test specification, methods and procedures.................................................................................................................. 12

    5.2.2 Test configuration.......................................................................................................................................................... 125.2.2.1 Environmental conditions: ........................................................................................................................................................ 125.2.2.2 Operating voltage: ..................................................................................................................................................................... 12

    5.2.2.3 Operating mode: ........................................................................................................................................................................ 12

    5.2.2.4 Line attenuation: ........................................................................................................................................................................ 12

    5.2.2.5 Support equipment: ................................................................................................................................................................... 12

    5.2.2.6 Cable lengths: ............................................................................................................................................................................ 12

    5.2.3 Tests results .................................................................................................................................................................... 13

    5.3 CONDUCTED EMISSIONS ................................................................................................................................................. 14

    5.3.1 EMISSION TESTS ON POWER CABLES..................................................................................................................... 145.3.1.1 Test specification, methods and procedures.............................................................................................................................. 14

    5.3.1.2 Test configuration...................................................................................................................................................................... 14

    5.3.1.2.1 Environmental conditions: ................................................................................................................................................... 14

    5.3.1.2.2 Operating voltage: ................................................................................................................................................................ 14

    5.3.1.2.3 Operating mode:................................................................................................................................................................... 14

    5.3.1.2.4 Line attenuation:................................................................................................................................................................... 14

    5.3.1.2.5 Support equipment: .............................................................................................................................................................. 14

    5.3.1.2.6 Cable lengths: ....................................................................................................................................................................... 14

    5.3.1.3 Tests results................................................................................................................................................................................ 14

    6 IMMUNITY TESTS.................................................................................................................................................................. 15

    6.1 PERFORMANCE CRITERIA OF SIGNAL INTERFACE.................................................................................................. 15

    6.2 RADIATED IMMUNITY TESTS (80MHZ2GHZ) ............................................................................................................ 16

    6.2.1 Test specification, methods and procedures.................................................................................................................. 16

    6.2.2 Test configuration.......................................................................................................................................................... 166.2.2.1 Environmental conditions: ........................................................................................................................................................ 16

    6.2.2.2 Operating voltage: ..................................................................................................................................................................... 16

    6.2.2.3 Operating mode: ........................................................................................................................................................................ 16

    6.2.2.4 Line attenuation: ........................................................................................................................................................................ 16

  • 8/10/2019 EMC TEST REPORT OF.PDF

    6/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    4/31

    6.2.2.5 Support equipment: ................................................................................................................................................................... 16

    6.2.2.6 Cable lengths: ............................................................................................................................................................................ 16

    6.2.3 Tests results .................................................................................................................................................................... 17

    6.3 POWER FREQUENCY MAGNETIC FIELD...................................................................................................................... 18

    6.3.1.1 Test specification, methods and procedures.............................................................................................................................. 186.3.1.2 Test configuration...................................................................................................................................................................... 18

    6.3.1.2.1 Environmental conditions: ................................................................................................................................................... 18

    6.3.1.2.2 Operating voltage: ................................................................................................................................................................ 18

    6.3.1.2.3 Operating mode:................................................................................................................................................................... 18

    6.3.1.2.4 Line attenuation:................................................................................................................................................................... 18

    6.3.1.2.5 Support equipment: .............................................................................................................................................................. 18

    6.3.1.2.6 Cable lengths: ....................................................................................................................................................................... 18

    6.3.1.3 Tests results................................................................................................................................................................................ 18

    6.4 CONDUCTED IMMUNITY TESTS .................................................................................................................................... 19

    6.4.1 IMMUNITY TESTS ON DC POWER CABLES............................................................................................................. 196.4.1.1 Test specification, methods and procedures.............................................................................................................................. 19

    6.4.1.2 Test configuration...................................................................................................................................................................... 19

    6.4.1.2.1 Environmental conditions: ................................................................................................................................................... 19

    6.4.1.2.2 Operating voltage: ................................................................................................................................................................ 196.4.1.2.3 Operating mode:................................................................................................................................................................... 19

    6.4.1.2.4 Line attenuation:................................................................................................................................................................... 19

    6.4.1.2.5 Support equipment: .............................................................................................................................................................. 20

    6.4.1.2.6 Cable lengths: ....................................................................................................................................................................... 20

    6.4.1.3 Tests results................................................................................................................................................................................ 20

    6.5 ELECTROSTATIC DISCHARGES (ESD)........................................................................................................................... 21

    6.5.1 Test specification, methods and procedures.................................................................................................................. 21

    6.5.2 Test configuration.......................................................................................................................................................... 216.5.2.1 Environmental conditions: ........................................................................................................................................................ 21

    6.5.2.2 Operating voltage: ..................................................................................................................................................................... 21

    6.5.2.3 Operating mode: ........................................................................................................................................................................ 21

    6.5.2.4 Line attenuation: ........................................................................................................................................................................ 21

    6.5.2.5 Support equipment: ................................................................................................................................................................... 216.5.2.6 Cable lengths: ............................................................................................................................................................................ 21

    6.5.3 Tested points................................................................................................................................................................... 22

    6.5.4 Tests results .................................................................................................................................................................... 22

    7 SUMMARY OF THE TESTS RESULTS .............................................................................................................................. 23

    7.1 MANDATORY EMISSION REQUIREMENTS. ................................................................................................................................ 23

    7.2 MANDATORY IMMUNITY REQUIREMENTS. .............................................................................................................................. 24

    7.3 VOLUNTARY EMISSION REQUIREMENTS. ................................................................................................................................. 25

    7.4 VOLUNTARY IMMUNITY REQUIREMENTS................................................................................................................................. 26

    7.5 R ADIATED EMISSION TESTS ...................................................................................................................................................... 27

    7.6 CONDUCTED EMISSION TESTS .................................................................................................................................................. 27

    7.7 R ADIATED IMMUNITY TESTS .................................................................................................................................................... 28

    7.8 POWER FREQUENCY MAGNETIC FIELD.............................................................................................................................. 28

    7.9 CONDUCTED IMMUNITY TESTS................................................................................................................................................. 29

    7.10 ESD TEST ............................................................................................................................................................................ 29

    8 TEST SITE CHARACTERISTICS......................................................................................................................................... 30

    8.1 TEN METERS SEMI ANECHOIC CHAMBER.................................................................................................................. 30

    8.2 THREE METERS FULLY ANECHOIC CHAMBER.......................................................................................................... 30

    9 ANNEX CONTENTS................................................................................................................................................................ 31

  • 8/10/2019 EMC TEST REPORT OF.PDF

    7/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    5/31

    1

    SCOPE

    The EMC tests were performed on the 1660SM Rel.5.2B, to demonstrate the compliance with the protection

    requirements of the Council Directive 89/336 EEC Article 10.1.

    The protection requirements for this type of equipment are covered by the following standards:

    - ETSI EN 300386 V1.3.2 (Ed. 05/2003) for transmission equipment, location "TELECOMMUNICATION

    CENTRES".

    Additional measurements have been performed, as requested by the customer, in accordance to the following

    voluntary requirements:

    -

    CISPR/I/105/CDV (ed. 2004)- CISPR/I/106/CDV (ed. 2004)

    for radiated emission above 1GHz (Frequency range test: 1 - 18 GHz).

    - ETSI ES 201468 v1.2.1 (ed. 09/2002):

    location " TELECOMMUNICATION CENTRES " "LEVEL 2" for immunity requirements.

    2

    CONCLUSIONS

    The tests performed, the reference standards and the test results are summarised in the paragraph 7.

    Details on each test are described in the relevant paragraphs.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    8/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    6/31

    3

    EQUIPMENT UNDER TEST (EUT)

    3.1

    Identification of the EUT

    Brand name:ALCATEL

    Model name:1660SM Rel.5.2B

    Unique type identification:cod. 3AL 81407 ACAA

    Serial N: Not applicable

    Date of receipt:26thOctober 2004

    Documentation submitted by the manufacturer: Technical Description 3AL 78911 0758 DSBUF.

    3.2

    Description of the EUTThe 1660SM Rel.5.2B is a synchronous multiplexing system which controls asynchronous tributaries (2Mbit/s,

    34Mbit/s, 45Mbit/s, 140Mbit/s) and synchronous into a 155Mbit/s signal line (on optical fibre or cable), into a

    622Mbit/s signal (on optical fibre) or into a 2488Mbit/s signal (on optical fibre) and Ethernet 10/100 interfaces

    (cable) , Gb Ethernet interfaces (optical fiber) and ATM interfaces.

    The EUT can be supplied by 4860 VDC battery. It can be installed in "TELECOMMUNICATION CENTRES"

    location.

    3.3

    EUT Configuration

    The configuration for the EMC tests, identified by the manufacturer is composed by:

    Subrack 1660SM Shelf Code Pos.

    N1 1660 SM SHELF 3AL78834AAAE

    N2 BUS TERMINATION 3AL79088ACAA

    N1 SERVICE I/F 3AL78817AAAF 11

    N1 EQUIP. CONTROLLER EQUICOE 3AL78836ABAA 22

    N1 STM16 Slim Port UP/SFP 3AL81289AAAA 33

    N1 Optical Access 12xSTM1 3AL89669AAAA 8

    N1 2xCH Transponder SFP W/O Optics 3AL81427AAAA 34

    N1 ISA ES 16 Board 3AL81915AAAA 37

    N1 ISA GBE Access 3AL80411ABAA 18

    N2 Port 16xSTM1 - 4x STM4 3AL89668AAAA 29-30N1 MUX-DEMUX 8CH 3AL81348AAAA 2-3

    N1 COADM 1CH (1550) 3AL81344AEAA 15-16

    N1 COADM 2CH (1570) 3AL81346ACAA 13-14

    N2 MATRIX ENH. 3AL81072AAAC 23-40

    N2 Control and general I/F CONGI 3AL78830ADAA 10-12

    N16 OPTO TRX SFP S-1.1 Plugin 1AB194670001 8-30

    N4 OPTO TRX SFP S-4.1 Plugin 1AB196360001 29

    N1 OPTO TRX SFP S-16.1 Plugin 1AB196370001 34

    N3 OPTO TRX SFP L-16.1 Plugin 1AB196370004 33-34

    N1 CWDM 1490NM ADP Plugin 1AB196350002 34

  • 8/10/2019 EMC TEST REPORT OF.PDF

    9/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    7/31

    N10 Dummy plate W20 3AN49397AAAA 1-9-17-21-26-27

    28-31-32-41

    N8 Dummy plate W40 3AN49589AAAA 4-5,6-7,13-14

    15-16,19-20,24-25,35-36,38-39

    FAN SHELF 19

    Code

    N1 FAN SHELF 19 3AL79773AAAA

    N4 FAN UNIT FOR SHELF 19 3AL79772AAAC

    N2 ANTI-DUST FILTER FOR SHELF 19 3AL80371AAAB

    N.B. The 75 Ohm interfaces have the shield connected to ground.

    3.4

    Card Pre-setting Straps

    All tests were performed with the electrical units set according to the default factory pre-setting as defined in the

    product documentation.

    3.5

    Modifications incorporated in the EUT (not in the product documentation)

    None.

    3.6

    Support Equipment

    Description: SDH/PDH TEST SET

    Brand name: HP

    Model: 37724A

    Serial:

    Alcatel code: L67KWV08

    Calibration expiry:Not included in the calibration plane.

    Inter-connection cables:

    Description: 155/622 MB/s OPTICAL INTERFACE 1310 nm.

    Brand name: HP

    Model: 37776A

    Serial:Alcatel code: L36LTV01

    Calibration expiry:Not included in the calibration plane.

    Inter-connection cables: n2 optical fibres

    Description: PDH/SDH ATM TEST SET

    Brand name: HP

    Model: 37717C

    Serial:

    Alcatel code: L67MMV02

    Calibration expiry:Not included in the calibration plane.

    Inter-connection cables: n2 optical fibres

  • 8/10/2019 EMC TEST REPORT OF.PDF

    10/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    8/31

    4

    REFERENCE STANDARDS

    The reference standards for this report are listed below.

    1)

    EN 55022: "LIMITS AND METHODS OF MEASUREMENT OF RADIO INTERFERENCE

    CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT". [SEPTEMBER 1998]

    1a) EN 55022/A1: "INFORMATION TECHNOLOGY EQUIPMENT, RADIO DISTURBANCE

    CHARACTERISTICS, LIMITS AND METHODS OF MEASUREMENT". [OCTOBER 2001]

    2)

    EN 61000-4-2: "ELECTROMAGNETIC COMPATIBILITY, PART 4: TESTING AND MEASUREMENT

    TECHNIQUES, SECTION 2: ELECTROSTATIC DISCHARGE IMMUNITY TEST". [MARCH 1995]

    3)

    EN 61000-4-3: "ELECTROMAGNETIC COMPATIBILITY, PART 4: TESTING AND MEASUREMENT

    TECHNIQUES, SECTION 3: RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD

    IMMUNITY TEST". [SEPTEMBER 1996]

    3a) EN 61000-4-3/A1: "ELECTROMAGNETIC COMPATIBILITY, PART 4/3: TESTING AND

    MEASUREMENT TECHNIQUES, SECTION 3: RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC

    FIELD IMMUNITY TEST". [AUGUST 1998]

    4)

    EN 61000-4-4: "ELECTROMAGNETIC COMPATIBILITY, PART 4: TESTING AND MEASUREMENT

    TECHNIQUES, SECTION 4: ELECTRICAL FAST TRANSIENTS/BURST IMMUNITY TEST". [MARCH

    1995]

    5)

    EN 61000-4-5: "ELECTROMAGNETIC COMPATIBILITY, PART 4: TESTING AND MEASUREMENT

    TECHNIQUES, SECTION 5: SURGE IMMUNITY TEST". [MARCH 1995]

    6)

    EN 61000-4-6: "ELECTROMAGNETIC COMPATIBILITY, PART 4: TESTING AND MEASUREMENT

    TECHNIQUES, SECTION 6: IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO

    FREQUENCY FIELDS". [JULY 1996]

    7)

    EN 61000-4-8: "ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4: TESTING AND

    MEASUREMENT TECHNIQUES- SECTION 8: POWER FREQUENCY MAGNETIC FIELD IMMUNITY

    TEST". [SEPTEMBER 1993]

    8)

    ETSI EN 300 386 v1.3.2: "ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM

    MATTERS (ERM);TELECOMMUNICATIONS NETWORK EQUIPMENT; ELECTROMAGNETIC

    COMPATIBILITY (EMC) REQUIREMENTS" [MAY 2003]

    9)

    ETSI ES 201 468 v1.2.1: "ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM

    MATTERS (ERM) ; ADDITIONAL ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS

    AND RESISTIBILITY REQUIREMENTS FOR TELECOMMUNICATIONS EQUIPMENT FOR ENHANCED

    AVAILABILITY OF SERVICE IN SPECIFIC APPLICATION" [SEPTEMBER 2002]

    10)

    CISPR 22: "INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE

    CHARACTERISTICS-LIMITS AND METHODS OF MEASUREMENT. [NOVEMBER 1997]

    11)

    CISPR/I/105/CDV: : AMENDMENT OF CISPR 22 (EMISSION LIMITS AND METHOD OF

    MEASUREMENT FROM 1GHz TO 6GHz). [2004]

  • 8/10/2019 EMC TEST REPORT OF.PDF

    11/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    9/31

    12)

    CISPR/I/106/CDV: AMENDMENT OF CISPR 22 (EMISSION LIMITS AND METHOD OF

    MEASUREMENT FROM 6GHz TO 18GHz). [2004]

    13)

    CISPR PUB. 16.1: "CISPR SPECIFICATION FOR RADIO INTERFERENCE MEASURING

    APPARATUS AND MEASUREMENT METHODS - PART 1: RADIO DISTURBANCE AND IMMUNITY

    MEASURING APPARATUS". [AUGUST 1993]

    14)

    CISPR PUB. 16.4: SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING

    APPARATUS AND METHODS. - PART 4: UNCERTANTY IN EMC MEASUREMENTS [MAY 2002]

  • 8/10/2019 EMC TEST REPORT OF.PDF

    12/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    10/31

    5

    EMISSION TESTS

    5.1

    RADIATED EMISSIONS TESTS (PLANE WAVE)

    Date of tests:5thNovember 2004 Test performed by: G. Mangili

    5.1.1

    Test specification, methods and procedures

    Test specifications:

    - the test limits are defined in: EN 55022 [Reference 1]

    - the test method is defined in: EN 55022 [Reference 1]

    Test method:

    The test was performed according to EN 55022. The worst emission was searched with several cables position.

    The receiving antenna was placed at distance of 10 m from the EUT border with scanning in height from 1 to 4 m.

    The EUT was turned from 0to 360.The test was performed in the semi-anechoic chamber whose characteristics are reported in the paragraph 9.

    Test lay out:

    The EUT was placed on an isolated table at 0.1m from ground floor.

    The EUT configuration was provided by the customer. The ports were connected with the cables specified in the

    product Technical Description (3AL 78911 0758 DSBUF).

    The test lay out is in the Annex 2, figure B.

    5.1.2

    Test configuration

    5.1.2.1

    Environmental conditions:

    Temperature 21C, Humidity 50%

    5.1.2.2

    Operating voltage:

    The EUT input voltage was -48VDC

    5.1.2.3

    Operating mode:

    The test was performed with the optical stream cables connected to the SDH/PDH TEST SET.

    The block scheme of the EUT configuration is in the annex 2 figure A.

    5.1.2.4

    Line attenuation:

    None

  • 8/10/2019 EMC TEST REPORT OF.PDF

    13/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    11/31

    5.1.2.5

    Support equipment:

    ANT-20 WANDEL & GOLTERMANN

    5.1.2.6

    Cable lengths:

    The length of cables are:

    Signal Number and type of cable Code Length

    Battery Interface Sub.

    1660 SM

    N 2 shielded bipolar

    cables041.931.031 2.5 m

    Battery Interface Fan shelf N 2 shielded bipolar cable 041.931.031 2.5 m

    GB Ethernet interfaceN 5 optical fibres multi

    mode

    Optical interface STM-1 N 17 optical fibres singlemode

    Optical interface STM-4N 5 optical fibre single

    mode

    Optical interface STM-16N 5 optical fibre single

    mode

    Ground connection N 1 cable

    5.1.3

    Tests results

    The maximum emissions are shown in Annex 1 figures1.1 and 1.2.

    The test result is in COMPLIANCEto the requirements of the standard EN 55022 class A as the emissions are

    under the quasi-peak limits with a margin higher than the uncertainty interval.

    The uncertainty interval "U", based on the 95% level of confidence (determined with the procedure N 8BP400500016URBUF, Annex 1, of this laboratory based on the CISPR 16-4), is:

    frequency range Polarisation uncertainty

    30 MHz - 200 MHz Horizontal +4.2dB / -4.1dB

    30 MHz - 200 MHz Vertical +4.5dB / -4.4dB

    200 MHz - 1000 MHz Horizontal and Vertical 3.6dB

    For test instrumentation and their uncertainties, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    14/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    12/31

    5.2

    RADIATED EMISSIONS TESTS (PLANE WAVE) 1 - 18 GHz

    Date of tests:24thNovember 2004 Test performed by: G. Mangili

    5.2.1

    Test specification, methods and procedures

    Test specifications:

    - the test limits are defined in: CISPR/I/105/CDV 1GHz-6GHz (amendment of CISPR 22) [Reference 11]

    CISPR/I/106/CDV 6GHz-18GHz (amendment of CISPR 22) [Reference 12]

    - the test method is defined in: CISPR/I/105/CDV 1GHz-6GHz (amendment of CISPR 22) [Reference 11]

    CISPR/I/106/CDV 6GHz-18GHz (amendment of CISPR 22) [Reference 12]

    Test method:

    The test was performed according to the CISPR/I/105/CDV and CISPR/I/106/CDV with the receiving antennaplaced at a distance of 3m from the border of the EUT. The antenna was a double-ridged, with peak-detector

    (1MHz of resolution bandwidth) as requested by the CISPR/I/105/CDV and CISPR/I/106/CDV. This test was

    performed with antenna height of 1m and turning the EUT from 0 to 360.

    The test was performed in the semi-anechoic chamber whose characteristics are reported in the paragraph 9.

    Additional RF absorber were placed on the floor to guarantee free-reflection conditions as requested by the

    reference document.

    Test lay out:

    The EUT was placed on an isolated table at 0.1m from ground floor.

    The EUT configuration was provided by the customer. The ports were connected with the cables specified in the

    product Technical Description (3AL 78911 0758 DSBUF).

    The test lay out is in the Annex 2, figure C.

    5.2.2

    Test configuration

    5.2.2.1

    Environmental conditions:

    Temperature 20C, Humidity 53%

    5.2.2.2

    Operating voltage:

    The EUT input voltage was -48VDC

    5.2.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    5.2.2.4

    Line attenuation:

    None

    5.2.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    5.2.2.6

    Cable lengths:

    See paragraph 5.1.2.6.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    15/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    13/31

    5.2.3

    Tests results

    The test result is in COMPLIANCE to the requirements of the documents CISPR/I/105/CDV and

    CISPR/I/106/CDV as the emissions are under the peak and the average limits (peak detector) with a margin higher

    than the uncertainty interval.

    The uncertainty interval, based on the 95% level of confidence (determined with the procedure N8BP400500016URBUF, Annex 1, of this laboratory based on the document CISPR 16-4), is:

    frequency range 1.0 GHz - 2.9 GHz +2,7dB / -2,8dB

    frequency range 2.9 GHz - 6,5 GHz +3,4dB / -3,6dB

    frequency range 6,5 GHz - 13,2 GHz +4.2dB / -4.8dB

    frequency range 13,2 GHz - 18 GHz +4.2dB / -4.5dB

    The maximum emissions are shown in the graphs in Annex 1, figure 1.3 .

    For test instrumentation and their uncertainties, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    16/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    14/31

    5.3

    CONDUCTED EMISSIONS

    5.3.1

    EMISSION TESTS ON POWER CABLES

    Date of tests:8thNovember 2004 Test performed by: G. Mangili

    5.3.1.1

    Test specification, methods and procedures

    Test specification:

    - the test limits are defined in: EN 55022 [Reference 1]

    - the test method is defined in: EN 55022 [Reference 1]

    Test method:

    The test was performed with the LISN (Line Impedance Stabilisation Network) defined in the EN 55022

    [Reference 1].

    Test lay out:

    The EUT configuration was provided by the customer. The ports were connected with the cables specified in the

    product Technical Description (3AL 78911 0758 DSBUF).

    The test lay out is in the Annex 2, figure D.

    5.3.1.2

    Test configuration

    5.3.1.2.1

    Environmental conditions:

    Temperature 21C, Humidity 51%

    5.3.1.2.2

    Operating voltage:The EUT input voltage was -48VDC

    5.3.1.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    5.3.1.2.4

    Line attenuation:

    None

    5.3.1.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    5.3.1.2.6

    Cable lengths:See paragraph 5.1.2.6.

    5.3.1.3

    Tests results

    The maximum emissions are shown in Annex 1 figures 1.4 and 1.5.

    The test is in COMPLIANCEto the requirements of the standard EN 55022 class A as the emissions are under

    the average and quasi-peak limits with a margin higher than the uncertainty interval.

    The uncertainty interval, based on the 95% level of confidence (determined with the procedure N8BP400500016URBUF, Annex 2, of this laboratory), is:

    frequency range 150 kHz - 30 MHz 3.0 dB

    For test instrumentation and their uncertainties, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    17/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    15/31

    6

    IMMUNITY TESTS

    The EUT interfaces monitored during the immunity tests are:

    N.1 channel 155Mbit/s optical stream connected to HP37724A

    N.1 channel 622Mbit/s optical stream connected to HP37717C

    Local alarms on frontal unit (LED's).

    6.1

    PERFORMANCE CRITERIA OF SIGNAL INTERFACE

    The performance criteria applied, derived from the EN 300386 V1.3.2 (ed.05/2003) valid also for the document

    ETSI ES 201468 v1.2.1 (ed. 09/2002) (see NOTE 1) and from customer's specifications, are the following:

    - Performance criterion A (continuous phenomena)

    The EUT has to operate correctly without signal and software degradation during and after the test.

    155 and 622Mbit/s optical stream: no bit errors, loss of frame or loss of synchronisation are allowed during andafter the test.

    During Conducted Immunity tests some signal degradation is allowed (additional errors) if the system is adaptive

    that is, testing again with interfering signal in the frequency range where degradation was verified, the system re-

    trains.

    Because the customer has not declared that the system is adaptive, during Conducted Immunity tests some signal

    degradation is not allowed.

    Alarm interface: no alarms or false alarms are allowed during and after the test.

    - Performance criterion B (transient phenomena)

    The EUT has to operate correctly without signal and software degradation after the application of the test.

    155 and 622Mbit/s optical stream: no loss of frame or loss of synchronisation are allowed during and after the

    test.

    -This doesn't apply to surge testing where some loss of frame alignment may be expected. However, the EUT

    shall continue to operate as intended after the test

    Alarm interface: no alarms or false alarms are allowed after the test.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    18/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    16/31

    6.2

    RADIATED IMMUNITY TESTS (80MHz2GHz)

    Date of tests: 26thOctober 2004 Test performed by: G.Mangili

    6.2.1

    Test specification, methods and procedures

    Test specification:

    - the test levels are defined in: ETSI EN 300 386 [Reference 8]

    ETSI ES 201 468 [Reference 9]

    - the test method is defined in: EN 61000-4-3 [Reference 3]

    EN 61000-4-3/A1 [Reference 3a]

    Test method:

    The test method applied is defined in the basic standard EN 61000-4-3+A1.

    The graphs concerning the field distribution on the 16 points defined by the standard EN 61000-4-3 are available

    by this laboratory.The distance between the antennas and the centre of the volume occupied by the EUT was 3m.

    The field calibration was performed without modulation of the signal, whereas the test was carried out with 80%

    AM modulated with 1kHz. The frequencies increment steps were 1% of the fundamental.

    The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.

    Test lay out:

    The EUT configuration was provided by the customer. The ports were connected with the cables specified in the

    product Technical Description (3AL 78911 0758 DSBUF).

    The test lay out is in the Annex 2, figure E for the frequency range 80MHz-1000MHz, and figure F for the

    frequency range 1GHz-2GHz.

    6.2.2

    Test configuration

    6.2.2.1

    Environmental conditions:

    Temperature 22C, Humidity 47%

    6.2.2.2

    Operating voltage:

    The EUT input voltage was -48VDC

    6.2.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    6.2.2.4

    Line attenuation:None

    6.2.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    6.2.2.6

    Cable lengths:

    See paragraph 5.1.2.6.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    19/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    17/31

    6.2.3

    Tests results

    The EUT operated correctly as intended without signal and software degradation.

    The test result is in COMPLIANCE with the performance Criterion A for interference level of 10V/m, as

    requested by the standard ETSI EN 300386 v1.3.2 and the document ETSI ES 201468 v1.2.1 for voluntary

    requirements (Level 2 for TLC centres).

    The field was calibrated in horizontal and vertical polarisation with field intensity of 0/+6dB on the nominal

    value. The reading uncertainty of the field sensor is:

    HORIZONTAL POSITION

    frequency range 80MHz - 2000MHz 2.0dB

    VERTICAL POSITION

    frequency range 80MHz - 2000MHz 2.0dB

    For test instrumentation and measurement uncertainty, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    20/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    18/31

    6.3

    POWER FREQUENCY MAGNETIC FIELD

    Date of tests:29th

    October 2004 Test performed by: G.Mangili

    6.3.1.1

    Test specification, methods and procedures

    Test specification:

    - the test levels are defined in: ETSI ES 201 468 [Reference 9]

    - the test methods are defined in: EN 61000-4-8 [Reference 7]

    Test method:

    The calibration of the interfering magnetic field was carried out in absence of the EUT, using a magnetic field

    meter placed in the centre of the induction coil. The magnetic field was calibrated in order to guarantee the field

    intensity level requested. The interfering field was applied to the EUT by the immersion method (according to the

    sub-clause 4.4 of the basic standard), placing the coil on each orthogonal axis.The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.

    Test lay out:

    The test lay out is in the Annex 2, figure G.

    6.3.1.2

    Test configuration

    6.3.1.2.1

    Environmental conditions:

    Temperature 21C, Humidity 50%

    6.3.1.2.2

    Operating voltage:The EUT input voltage was -48VDC

    6.3.1.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    6.3.1.2.4

    Line attenuation:

    None

    6.3.1.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    6.3.1.2.6

    Cable lengths:See paragraph 5.1.2.6.

    6.3.1.3

    Tests results

    The EUT continued to operate correctly as intended without signal or software degradation. The test result is in

    COMPLIANCEwith the performance criterion A for magnetic field intensity of 3 A/m, as requested by the

    document ETSI ES 201468 v1.2.1, voluntary requirements "level 2".

    Furthermore the field intensity was increased till 30 A/m and the EUT continued to operate correctly as intended

    without signal or software degradation, in compliance to the performance criterion A.

    The current generator used is within the tolerance of 8%, as defined in the basic standard EN 61000-4-8.

    For test instrumentation and their uncertainties, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    21/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    19/31

    6.4

    CONDUCTED IMMUNITY TESTS

    6.4.1

    IMMUNITY TESTS ON DC POWER CABLES

    Date of tests: EFT 28thOctober 2004 CW 29

    thOctober 2004 Test performed by: G.Mangili

    6.4.1.1

    Test specification, methods and procedures

    Test specification:

    - the test levels are defined in: ETSI EN 300386 [Reference 8]

    ETSI ES 201 468 [Reference 9]

    the test methods are defined in:

    EFT (Electrical Fast Transient) EN 61000-4-4 [Reference 4]

    CW (Continuous Wave) 150KHz-80MHz EN 61000-4-6 [Reference 6]

    The tests were performed on the DC power cables. Each cable was tested separately.

    Test method:

    - EFT (Electrical Fast Transient): the EFT's were injected into the wires at a distance of 1m from the EUT

    power input. The interference was injected in common mode for 2 minutes in each polarity. The reference test

    method is in the basic standard EN61000-4-4, sub-clause 7.2.2 "Methods of coupling the test voltage to the EUT:

    power supply lines".

    - CW (Continuous Wave) 150kHz-80MHz:the interfering signal was injected into the wires at 0.3m from the

    EUT power input port, with the equipment floating from the ground. The interference was injected using theCDN-M2 according to the method described in the basic standard EN61000-4-6 sub-clause 6.2.2 "Coupling and

    decoupling network".

    The interfering signal was 80% AM modulated with 1kHz.

    The frequencies increment steps were 1% of the fundamental.

    The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.

    Test lay out:

    The test lay out is in the Annex 2, figures H (EFT) and I (CW).

    6.4.1.2

    Test configuration

    6.4.1.2.1

    Environmental conditions:

    EFT Temperature 21C, Humidity 52%

    CW Temperature 21C, Humidity 50%

    6.4.1.2.2

    Operating voltage:

    The EUT input voltage was -48VDC

    6.4.1.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    6.4.1.2.4

    Line attenuation:

    None

  • 8/10/2019 EMC TEST REPORT OF.PDF

    22/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    20/31

    6.4.1.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    6.4.1.2.6

    Cable lengths:

    See paragraph 5.1.2.6.

    6.4.1.3

    Tests results

    - EFT (Electrical Fast Transients):

    The EUT continued to operate correctly as intended without signal or software degradation.

    The test result is in COMPLIANCEwith the performance criterion A for interference of 0.5kV. For this test the

    standard ETSI EN 300386 v1.3.2 requests the performance criterion B, while the EUT is compliant with the more

    severe performance criterion A.

    Furthermore the EUT is in COMPLIANCEwith the performance Criterion A for interference level of 1.0kV.

    For this test the document ETSI ES 201468 v1.2.1, for voluntary requirements (Level 2 for TLC centres), requests

    the performance criterion B, while the EUT is compliant with the more severe performance criterion A.

    The pulse characteristics have been measured at the output of the generator and are within the tolerance of 10%,as defined in the basic standard EN 61000-4-4.

    - CW (Continuous Wave) 150kHz - 80MHz:

    The EUT continued to operate correctly as intended without signal or software degradation.

    The test result is in COMPLIANCEwith the performance criterion A for interference of 3V (rms), as requested

    by the standard ETSI EN 300386 v1.3.2.

    Furthermore the EUT is in COMPLIANCEwith the performance criterion A for interference level of 10V (rms),

    as requested by the document ETSI ES 201468 v1.2.1, for voluntary requirements (Level 2 for TLC centres).

    The interfering signal was calibrated with an uncertainty interval, based on the 95% level of confidence

    determined with the procedure N 8BP400500016URBUF, Annex 4, of this laboratory.

    The calibration uncertainty of the interference voltage is:

    frequency range 150 kHz - 80 MHz 1.6 dB

    For test instrumentation and their uncertainties, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    23/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    21/31

    6.5

    ELECTROSTATIC DISCHARGES (ESD)

    Date of tests: 28thOctober 2004 Test performed by: G.Mangili

    6.5.1

    Test specification, methods and procedures

    Test specification:

    - the test limits are defined in: ETSI EN 300 386 [Reference 8]

    - the test method is defined in: EN 61000-4-2 [Reference 2]

    Test method:

    The EUT was tested with the following methods:

    Direct discharges: the direct discharges were applied to the points and surfaces of the EUT that are

    accessible to personnel during normal usage.

    Each accessible point was tested with 10 discharges with positive polarity and 10 discharges with negative

    polarity. Air discharges were applied on not conductive points, while contact discharges were applied onconductive points according to the sub-clause 8.3.1 of the basic standard EN61000-4-2.

    Indirect discharges: according to the sub-clause 8.3.2 of the basic standard EN61000-4-2, the ESD were

    applied to a vertical coupling plane through a contact discharge adapter. The vertical coupling plane (0.5m x

    0.5m dimensions) was placed parallel to, and positioned at a distance of 0.1m, from each side of the EUT.

    On each side of the EUT were applied 10 discharges with positive polarity and 10 discharges with negative

    polarity.

    The ESD were not applied to pins of non-cabled connectors and to local monitoring ports as these are protected

    by proper caps.

    The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.

    Test lay out:

    The test lay out is in the Annex 2, figures L and M.

    6.5.2

    Test configuration

    6.5.2.1

    Environmental conditions:

    Temperature 21C, Humidity 52%

    6.5.2.2

    Operating voltage:

    The EUT input voltage was -48VDC

    6.5.2.3

    Operating mode:

    See paragraph 5.1.2.3.

    6.5.2.4

    Line attenuation:

    None

    6.5.2.5

    Support equipment:

    See paragraph 5.1.2.5.

    6.5.2.6

    Cable lengths:

    See paragraph 5.1.2.6.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    24/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    22/31

    6.5.3

    Tested points

    The EUT tested points are:

    DIRECT DISCHARGES ON NOT CONDUCTIVE SURFACES

    -

    Painted enclosure surfaces

    - Extraction levers.

    - LED's on frontal unit.

    - Plastic push button on frontal unit.

    - Plastic cover on uncabled BNC connector

    - Plastic cover on uncabled RS232 connector

    DIRECT DISCHARGES ON CONDUCTIVE SURFACES

    - Cover on wired connector (48VDC power supply)

    -

    Mechanical ground- Unit screws

    - Frontal units

    INDIRECT DISCHARGES

    - Vertical coupling plane.

    6.5.4

    Tests results

    The EUT was in COMPLIANCEto the more severe performance criterion A for Air discharges level of 4kV

    and for Contact discharges level of 4kV, instead of the performance criterion B as requested by the standard

    ETSI EN 300386 v1.3.2.Furthermore the EUT is COMPLIANCEto the more severe performance Criterion A for Air discharges level of

    8kV and for Contact discharges level of 6kV, instead of the performance criterion B as requested by the

    document ETS ES 201468 v1.2.1 for voluntary requirements (Level 2 for TLC centres).

    The tolerances of the generator are according to the basic standard EN61000-4-2:

    DC output voltage: 5%,

    Pulse: Peak current 10%, rise time: 10%, curve decay point at 30 and 60ns: 30%.

    For test instrumentation and their uncertainty, see paragraph 8.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    25/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    23/31

    7

    SUMMARY OF THE TESTS RESULTS

    7.1

    Mandatory Emission requirements.

    Reference of the Harmonised standard: EN 300386 V1.3.2 (ed.05/2003) Location: TLC Centres

    PHENOMENONBASIC

    STANDARDSREQUIREMENTS

    COMPLIANCE

    CLASS

    FIG. RESULT

    GRAPHSNOTE

    AC POWER CABLES

    0,15 MHZ-30 MHzEN 55022

    Required in the

    EN 300386 V1.3.2

    Par.6.1

    Limits defined in the

    EN 55022 Tab.2

    N.A. N.A. 2)

    DC POWER PORTS

    0,15 MHZ-30 MHzEN 55022

    Required in the

    EN 300386 V1.3.2

    Par.6.1

    Limits defined in the

    EN 55022 Tab.2

    COMPLIANCE Fig. 1.4, 1.5CONDUCTED

    EMISSIONS

    TELECOMMUNICATIONPORTS

    EN 55022

    Required in the

    EN 300386 V1.3.2Par.6.1

    Limits defined in the

    EN 55022 Tab.4

    N.A. N.A.

    HARMONICS AC POWER PORTS EN 61000-3-2

    Required in the

    EN 300386V1.3.2par.6.1

    Requirements

    See basic std.

    N.A. N.A. 2)

    VOLTAGE

    FLUCTUATIONAC POWER PORTS EN 61000-3-3

    Required in the

    EN 300386V1.3.2par.6.1

    Requirements

    See basic std.

    N.A. N.A. 2)

    RADIATED

    EMISSIONS

    PLANE WAVE

    30 MHz - 1 GHzEN 55022+A1

    Required in the

    EN 300386 V1.3.2Par.6.1

    Limits defined in the

    EN 55022 Tab.6

    COMPLIANCE Fig. 1.1, 1.2 1)

    NOTE:

    1) In the configuration of the apparatus under test has been applied the standard EN 55022/A1 (ed.10/2001),

    requested for floor-standing equipment; about other tests we referred to the standard EN 55022 (ed.09/98).

    2) N.A: Not Applicable because the apparatus is DC power supply.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    26/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    24/31

    7.2

    Mandatory Immunity requirements.

    Reference of the Harmonised standard: EN 300386 V1.3.2 (ed.05/2003) Location: TLC Centres

    TEST LEVELPHENOMENON

    BASIC

    STANDARDSREQUIREMENTS RESULTS

    REF.COMPL.

    CRITER.

    RESULTCOMPL.

    CRITER.

    NOTE

    ELECTROSTATIC

    DISCHARGES (ESD)EN 61000-4-2

    4 kV cont.

    4 kV air

    4 kV cont.

    4 kV air

    COMPLIANCE

    B

    B

    A

    A

    RADIATED IMMUNITY (80-2000MHz) EN 61000-4-3+A1

    80-800MHz 3 V/m

    800-960MHz 10 V/m

    960-1000MHz 3 V/m

    1.4-2.0GHz 10 V/m

    10 V/m

    10 V/m

    10 V/m

    10 V/m

    COMPLIANCE

    A

    A

    A

    A

    A

    A

    A

    A

    AC POWER

    PORTS EN 61000-4-4 1.0 kV N.A. B N.A. 2)

    DC POWER

    PORTSEN 61000-4-4 0.5 kV

    0.5 kV

    COMPLIANCEB A

    INDOOR SIGNAL

    CABLESEN 61000-4-4 0.5 kV N.A. B N.A. 3)

    ELECTRICAL

    FAST

    TRANSIENT

    (EFT)

    OUTDOOR

    SIGNAL CABLESEN 61000-4-4 0.5 kV N.A. B N.A. 1)

    INDOOR SIGNAL

    CABLES1.2s/50s

    EN 61000-4-5 0.5 kV N.A. B N.A. 3)

    OUTDOOR

    SIGNAL CABLES1.2s/50s

    EN 61000-4-5 1.0 kV N.A. B N.A. 1)SURGES

    AC POWER

    PORTS1.2s/50s

    EN 61000-4-5

    0.5 kV (line to line.)

    1.0 kV(line to

    ground)

    N.A.B

    BN.A. 2)

    VOLTAGE DIPS

    and SHORT

    INTERRUPTIONS

    AC POWER

    PORTSEN 61000-4-11

    >95% 10 ms

    30% 500 ms

    >95% 5000ms

    N.A.

    B

    C

    C

    N.A. 2)

    POWER CABLES

    (DC)EN 61000-4-6 3 V

    3 V

    COMPLIANCEA A

    POWER CABLES

    (AC)EN 61000-4-6 3 V N.A. A N.A. 2)

    OUTDOOR

    SIGNAL CABLESEN 61000-4-6 3 V N.A. A N.A. 1)

    CONDUCTED

    IMMUNITY

    CW

    (0.15-80 MHz)

    INDOOR SIGNAL

    CABLESEN 61000-4-6 3 V N.A. A N.A. 3)

    NOTE:

    1) N.A.: Not Applicable because no cable is considered "OUTDOOR SIGNAL LINE".

    2) N.A.: Not Applicable because the apparatus is DC power supply.

    3) N.A.: Not Applicable because no cable is considered "INDOOR SIGNAL LINE".

  • 8/10/2019 EMC TEST REPORT OF.PDF

    27/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    25/31

    7.3

    Voluntary Emission requirements.

    EMISSION REQUIREMENTS

    The requirements of the reference documentETSI ES 201468 V1.2.1 (ed.09/2002) are the same of the Standard

    EN 300386 V1.3.2 (ed.05/2003).

    Reference document: CISPR/I/105/CDV and CISPR/I/106/CDV (ed. 2004) Location: TLC Centres

    PHENOMENON BASICSTANDARDS

    REQUIREMENTS COMPLIANCECLASS

    FIG. RESULTGRAPHS

    NOTE

    RADIATED

    EMISSIONS

    PLANE WAVE

    1 GHz -18 GHz

    CISPR/I/105/CDV

    CISPR/I/106/CDV

    Limits defined in

    table 7

    COMPLIANCE

    Tab.7Fig. 1.3

  • 8/10/2019 EMC TEST REPORT OF.PDF

    28/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    26/31

    7.4

    Voluntary Immunity requirements.

    Reference document: ETSI ES 201468 V1.2.1(ed. 09-2002) Level 2 - Location: TLC Centres

    TEST LEVELPHENOMENON

    BASIC

    STANDARDSREQUIREMENTS RESULTS

    REF.COMPL.

    CRITER.

    RESULTCOMPL.

    CRITER.

    NOTE

    ELECTROSTATIC

    DISCHARGES (ESD)EN 61000-4-2

    6 kV cont.

    8 kV air

    6 kV cont.

    8 kV air

    COMPLIANCE

    B

    B

    A

    A

    RADIATED IMMUNITY (80-2000MHz) EN 61000-4-3 10 V/m10 V/m

    COMPLIANCEA A

    POWER FREQUENCY

    MAGNETIC FIELDEN 61000-4-8 3 A/m (rms)

    30 A/m (rms)

    COMPLIANCEA A

    AC POWER PORTS EN 61000-4-4 2.0 kV N.A. B N.A. 3)

    DC POWER PORTS EN 61000-4-4 1.0 kV1.0 kV

    COMPLIANCEB A

    INDOOR SIGNAL

    CABLESEN 61000-4-4 1.0 kV N.A. B N.A. 4)

    ELECTRICAL

    FAST

    TRANSIENT

    (EFT)

    OUTDOOR SIGNAL

    CABLESEN 61000-4-4 1.0 kV N.A. B N.A. 1)

    INDOOR SIGNALCABLES 1.2s/50s

    EN 61000-4-5 0.5 kV N.A. B N.A. 4)

    EN 61000-4-5 1.0 kV) N.A.B

    BN.A. 1)

    OUTDOOR

    SIGNAL LINES

    1.2s/50s

    (10s/700s for ITU-T K20)

    ITU-T K204.0 kV

    1.0 kV N.A.R

    R N.A. 1)

    SURGES

    AC POWERPORTS 1.2s/50s

    EN 61000-4-5

    1.0 kV (line to line)

    2.0 kV (line to

    ground)

    N.A.B

    BN.A. 3)

    PERMANENT

    POWER

    INDUCTION

    OUTDOOR

    SIGNAL

    CABLES

    ITU-T K54

    60 V,

    15 min,

    50/162/3 Hz

    N.A. A N.A. 1)

    POWER

    INDUCTION

    OUTDOOR

    SIGNAL

    CABLES

    ITU-T K20

    600 V,

    200 ms,

    50 Hz

    N.A. R N.A.1)

    2)

    VOLTAGE DIPS and

    SHORT

    INTERRUPTIONS

    AC POWER PORTS EN 61000-4-11

    >95% 10 ms

    30% 500 ms

    >95% 5000ms

    N.A.

    B

    C

    C

    N.A. 3)

    AC POWER PORTS EN 61000-4-6 10 V N.A. A N.A. 3)

    DC POWER PORTS EN 61000-4-6 10 V10 V

    COMPLIANCEA A

    OUTDOOR SIGNAL

    CABLESEN 61000-4-6 10 V N.A. A N.A. 1)

    CONDUCTED

    IMMUNITY CW

    (0.15-80 MHz)

    INDOOR SIGNAL

    CABLESEN 61000-4-6 10 V N.A. A N.A. 4)

    NOTE: 1) N.A.: Not Applicable because no cable is considered "OUTDOOR SIGNAL LINE".

    2) Resistibility Tests are not mandatory for the compliance to the EMC Directive.3) N.A.: Not Applicable because the apparatus is DC power supply.

    4) N.A.: Not Applicable because no cable is considered "INDOOR SIGNAL LINE".

  • 8/10/2019 EMC TEST REPORT OF.PDF

    29/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    27/31

    TEST INSTRUMENTATION

    7.5

    Radiated emission tests

    These tests were carried out in the semi-anechoic chamber, see paragraph 9 for characteristics.

    Test instrumentation (30-1000 MHz):

    INSTRUMENT MODEL ALCATEL CODE

    - SPECTRUM ANALYZER .100Hz-22GHz HP 8566B 16712A04

    - PRESELECTOR 20Hz-2GHz HP 85685A 19816A00

    - QP ADAPTER 9kHz-1GHz HP 85650A 16642A00

    - BICONICAL ANTENNA EMCO 3108 L98DC001

    - LOG PERIODIC ANTENNA EMCO 3146 L98CZ003

    - PRE AMPLIFIER HP 8447D L05CC001

    - PRE AMPLIFIER ELECTRO-METRICS BPA-1000 L05CY002

    - COAXIAL CABLE CAVO 1

    - COAXIAL CABLE CAVO 6

    - COAXIAL CABLE CAVO 7

    Test instrumentation (1-18 GHz):

    INSTRUMENT MODEL ALCATEL CODE

    - SPECTRUM ANALYZER .100Hz-22GHz HP 8566B 16712A04

    - PRESELECTOR 20Hz-2GHz HP 85685A 19816A00

    - QP ADAPTER 9kHz-1GHz HP 85650A 16642A00

    - DOUBLE-RIDGED ANTENNA ELECTRO-METRICS RGA-60 L98HXV01

    - LOW NOISE PREAMPLIFIER.1-18 GHz. BONN.BLMA 0118-1A 404604600

    - COAXIAL CABLE CAVO 41

    - COAXIAL CABLE CAVO 42

    INSTRUMENTATION UNCERTAINTY (30-1000 MHz):

    -

    SPECTRUM ANALYSER Amplitude accuracy = 1dB- BICONICAL ANTENNA Calibration accuracy = 0.9dB

    - LOG PERIODIC ANTENNA Calibration accuracy = 1dB

    - COAXIAL CABLES Calibration accuracy = 1.1dB

    INSTRUMENTATION UNCERTAINTY (1-18 GHz):

    - SPECTRUM ANALYSER Amplitude accuracy (1GHz - 2.9GHz) = 0.8dB

    - Amplitude accuracy (2.9GHz - 6.5GHz) = 1.4dB

    - Amplitude accuracy (6.5GHz - 13.2GHz) = 2.2dB

    - Amplitude accuracy (13.2GHz - 18GHz) = 2.5dB

    - DOUBLE-RIDGED ANTENNA Calibration accuracy = 0.8dB

    - COAXIAL CABLES Calibration accuracy = 1.1dB

    7.6

    Conducted emission tests

    DC Ports

    These tests were carried out in the semi-anechoic chamber, see paragraph 9 for characteristics.

    INSTRUMENT MODEL ALCATEL CODE

    - SPECTRUM ANALYZER .100Hz-22GHz HP 8566B 16712A04

    - PRESELECTOR 20Hz-2GHz HP 85685A 19816A00

    - QP ADAPTER 9kHz-1GHz HP 85650A 16642A00

    - V-NETWORK LISN R&S ESH 3-Z5 L65AT002

    - COAXIAL CABLE CAV 53

    - COAXIAL CABLE CAV 56

    INSTRUMENTATION UNCERTAINTY:

    -

    SPECTRUM ANALYSER Amplitude accuracy = 1dB- V-NETWORK LISN Tolerance on the impedance curve = 20%

    - COAXIAL CABLES Calibration accuracy = 1.1dB

  • 8/10/2019 EMC TEST REPORT OF.PDF

    30/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    28/31

    7.7

    Radiated immunity tests

    These tests were carried out in the anechoic chamber, see paragraph 9 for characteristics. During this test, in the

    frequency range 1GHz-2GHz, additional absorbers were placed on the floor in order to get the field uniformity as

    requested by the basic standard EN61000-4-3.

    Test instrumentation (80-1000 MHz):

    INSTRUMENT MODEL ALCATEL CODE

    - CW GENERATOR MARCONI 2030 VI610612

    - POWER AMPLIFIER IFI M406 L05CU001

    - POWER AMPLIFIER AR 200W 1000M7A VI615395

    - BICONICAL ANTENNA EMCO 3109 403754900

    - LOG PERIODIC ANTENNA EMCO 3146 L98CZ002

    - FIELD PROBE HOLIDAY FP 3000 L40DN001

    - COAXIAL CABLE CAV 19

    - COAXIAL CABLE CAV 21

    Test instrumentation (1-2 GHz):

    INSTRUMENT MODEL ALCATEL CODE

    - SYNTHESISED SWEEPER HP 83620A L34N2V01

    - POWER METER HP 438A L28BRD03

    - POWER TWT AMPLIFIER LOGIMETRICS A610/L VI615398

    - CONTROL UNIT LOGIMETRICS MICROPROCESSOR VI616753

    - HORN ANTENNA LOGIMETRICS AN 8200 C VI616752

    - ISOTROPIC FIELD PROBE AR FP 2080 VI616749

    - ISOTROPIC FIELD MONITOR AR FM 2000 VI616745

    - COAXIAL CABLE CAV 32

    - COAXIAL CABLE CAV 33

    INSTRUMENTATION UNCERTAINTY (80-1000 MHz):- FIELD PROBE Calibration accuracy = 2.0dB on three orthogonal axes

    INSTRUMENTATION UNCERTAINTY (1-2 GHz):- ISOTROPIC FIELD PROBE Calibration accuracy = 1.1dB on three orthogonal axes

    7.8

    Power Frequency MAGNETIC FIELD

    INSTRUMENT MODEL ALCATEL CODE

    - ELF MAGNETIC FIELD METER HOLADAY HI-3627 3-AXIS VI623764

    - MAGNETIC FIELD GENERATOR DANA DAS-G 120 VI616422

    - INDUCTION COIL DANA DAS-S 120 (dimension 1x1 m)

    INSTRUMENTATION UNCERTAINTY:- MAGNETIC FIELD METER Calibration accuracy (at the calibration frequency) = 5%

    (According to EN 61000-4-8 requirements:

  • 8/10/2019 EMC TEST REPORT OF.PDF

    31/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    29/31

    7.9

    Conducted immunity tests

    Electrical Fast Transients (EFT):

    INSTRUMENT MODEL ALCATEL CODE- EFT GENERATOR EM TEST EFT 500 VI624893

    - COUPLER/DECOUPLER EM TEST CNI 503 VI624893

    - HIGH VOLTAGE PROBE TEKTRONIX P6015A L60C7V03

    - OSCILLOSCOPE TEKTRONIX 620A L35GBV01

    - COAXIAL CABLE CAV 51

    INSTRUMENTATION UNCERTAINTY:

    - EFT GENERATOR Rise time = CHARACTERISTICS ACCORDING

    - (Open circuit voltage) Pulse duration = TO EFT IMMUNITY TEST

    - Burst period = (EN61000-4-4)

    - OSCILLOSCOPE Vertical accuracy = 1%

    Time base accuracy = 0,01%

    Continuous wave (CW):

    INSTRUMENT MODEL ALCATEL CODE

    - SYNTHESISED GENERATOR 8662A Agilent L34PJV01

    - POWER AMPLIFIER AR 75A250 VI615396

    - POWER METER E 4419B L28MQV02

    - POWER METER Agilent E4419B L28MQV02

    - CDN 2 pole 25A, freq.150kHz230MHz 801-M2-25 FCC VI605532

    - CURRENT PROBE (monitoring probe) SCHAFFNER CSP 8455 403749300

    - ATTENUATOR (10dB) WEINSCHEL CORP 341034 BJ7046

    - ATTENUATOR (10dB) WEINSCHEL CORP 341034 BJ7047

    - COAXIAL CABLE CAV 14

    -

    INSTRUMENTATION UNCERTAINTY:

    -

    CDN 2 pole 25A 801-M2-25 FCC Calibration Accuracy = 2.0dB

    - COAXIAL CABLE Calibration Accuracy = 1.1dB

    7.10

    ESD test

    INSTRUMENT MODEL ALCATEL CODE

    - ESD SIMULATOR SCHAFFNER NSG 435 L34NLV01

    - VCP 0.5m x 0.5m + n2 RESISTORS (470K) ALCATEL

    INSTRUMENTATION UNCERTAINTY:

    - ESD SIMULATOR Tolerance of the output voltage = 10%

    (According to ESD EN 61000-4-2)

  • 8/10/2019 EMC TEST REPORT OF.PDF

    32/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    30/31

    8

    TEST SITE CHARACTERISTICS

    8.1

    TEN METERS SEMI ANECHOIC CHAMBER

    The test site is a shielded semi-anechoic chamber with the following characteristics:

    Internal size (distance between walls, absorber to absorber): 17.1m (l) x 10.1m (w) x 7.45m (h)

    RF attenuation in accordance to MIL STD 285

    magnetic field 70dB at 15kHz, 100dB at 100kHz to 10MHz

    electric field > 100dB 15KHz to 100MHz

    plane wave > 100dB 500MHz to 18GHz

    The chamber is a ground reflection design without absorber on the working floor surface.

    Thus, the chamber test environment can be related to an open area reflection test site. The site attenuation of the

    chamber is available in this laboratory.

    The test room is completed with the turntable and the antenna position mast.

    Measurement instrumentation is located in a shielded control room.

    For radiated immunity test the field uniformity is guaranteed over 75% of surface (1.5m x 1.5m, 0.8m above

    ground plane) with 42 pcs of ferrite plate absorber, installed on floor.

    8.2

    THREE METERS FULLY ANECHOIC CHAMBER

    The test site is a shielded fully anechoic chamber with the following

    characteristics:

    Internal size: 6.42m (l) x 3.97m (w) x 4.05m (h)

    RF attenuation in accordance to MIL STD 285

    magnetic field 50dB at 10kHz, 60dB at 100kHz

    electric field > 90dB

    plane wave > 90dB up to 1GHz

    For radiated emission test (frequency range 1-18 GHz) additional absorbers were placed on the floor in order to

    rely on free-reflection conditions, as requested by the reference document.

    For radiated immunity test (frequency range 1-2 GHz) the field uniformity is guaranteed over the 75% of thesurface (1.5m x 1.5m, 0.8m above ground plane) with additional absorbers, installed on the floor.

    The site attenuation of the chamber is available in this laboratory.

    The test room is completed with the turntable and the antenna position mast.

    Measurement instrumentation is located in a shielded control room.

  • 8/10/2019 EMC TEST REPORT OF.PDF

    33/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Report

    TR/EMC/02/067

    Pag.

    31/31

    9

    ANNEX CONTENTS

    ANNEX 1: MEASUREMENT GRAPHS.........................................................................pag.3

    ANNEX 2: TEST LAY-OUT's...............................................................................................pag.6

  • 8/10/2019 EMC TEST REPORT OF.PDF

    34/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Annex 1

    TR/EMC/02/067

    Pag.

    1/3

    ANNEX 1 MEASUREMENT GRAPHS

    Fig. 1.1 RADIATED EMISSION (plane wave) 30MHz200MHz

    Standard: EN55022, Class A QUASI-PEAK LIMIT, PEAK DETECTOR

    Fig. 1.2 RADIATED EMISSION (plane wave) 200MHz1GHzStandard: EN55022, Class A QUASI-PEAK LIMIT, PEAK DETECTOR

  • 8/10/2019 EMC TEST REPORT OF.PDF

    35/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Annex 1

    TR/EMC/02/067

    Pag.

    2/3

    Fig. 1.3 RADIATED EMISSION (plane wave) 1GHz18GHz

    PEAK AND AVERAGE LIMITS, PEAK DETECTOR

    Fig. 1.4 CONDUCTED EMISSION (150kHz30MHz) ON DC POWER CABLES (Positive)

    QUASI-PEAK AND AVERAGE LIMITS , PEAK DETECTOR

  • 8/10/2019 EMC TEST REPORT OF.PDF

    36/42

    ALCATEL ITALIA

    EMI-EMC LABORATORY

    Annex 1

    TR/EMC/02/067

    Pag.

    3/3

    Fig. 1.5 CONDUCTED EMISSION (150kHz30MHz) ON DC POWER CABLES (Negative)

    QUASI-PEAK AND AVERAGE LIMITS , PEAK DETECTOR

  • 8/10/2019 EMC TEST REPORT OF.PDF

    37/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    1/6

    ANNEX 2 TEST LAY OUT's

    Fig. A TEST LAY OUT: EUT configuration

  • 8/10/2019 EMC TEST REPORT OF.PDF

    38/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    2/6

    Fig. B TEST LAY OUT: Radiated emission(plane wave): Frequency range:301000MHz

    Fig. C TEST LAY OUT: Radiated emission(plane wave) Frequency range:118GHz

  • 8/10/2019 EMC TEST REPORT OF.PDF

    39/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    3/6

    Fig. D TEST LAY OUT: Conducted emission on DC power cables

    Fig. E TEST LAY OUT: Radiated immunity

    Frequency range:80MHz1000MHz

  • 8/10/2019 EMC TEST REPORT OF.PDF

    40/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    4/6

    Fig. F TEST LAY OUT: Radiated immunity

    Frequency range:1GHz2GHz

    Fig. G TEST LAY OUT: Power frequency magnetic field

  • 8/10/2019 EMC TEST REPORT OF.PDF

    41/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    5/6

    Fig. H TEST LAY OUT: Conducted immunity (EFT) on DC power cables

    Fig. I TEST LAY OUT: Conducted immunity (CW) on DC power cables

  • 8/10/2019 EMC TEST REPORT OF.PDF

    42/42

    ALCATE ITALIA

    EMI-EMC LABORATORY

    Annex 2

    TR/EMC/02/067

    Pag.

    6/6

    Fig. L TEST LAY OUT: Electrostatic discharge (direct method)

    Fig. M TEST LAY OUT: Electrostatic discharge (indirect method) vertical coupling plane