emc test report - tazla energy · this test report may be reproduced and shall only be reproduced...
TRANSCRIPT
Prepared for:
Product Name:
Model Number:
Test Standards:
Unit 8 Woodfieldside Business ParkPontllanfraith
Tazla Energy Ltd
BeCoola
EN 55014-1:2006 + A1:2009 + A2:2011*EN 55014-2:1997 + A1:2001 + A2:2008
SPARKSMD V1.3
EN 61000-3-2:2006 + A1:2009* + A2:2009*EN 61000-3-3:2008
Kiwa Blackwood Compliance Laboratories
EMC Test Report
Tested at:
R12-2468A issue 2 Page 1 of 25
BlackwoodNP12 2DGUnited KingdomTel: +44 (0) 1495 229219Web: www.kiwa.co.uk
Test Report Issue Date:
Tested by:
Test Engineer
Approved by:
Technical Management
This amended test report replaces all previous releases with the same report number and lower issue numbers.
Amendments marked with * are currently outside the scope of our UKAS accreditation.
The Digital Signatures used in this PDF report enable identification of the signatories.
The Signatures tab can be used to confirm that no changes were made to this document since it was signed.
This test report may be reproduced and shall only be reproduced in full.
If the integrity of any reproduction of this test report is in doubt contact Kiwa Blackwood Compliance Laboratories for validation.
Any opinions or interpretations given within this report are outside of the scope of the UKAS accreditation.
29 November 2012
R12-2468A issue 2 Page 1 of 25
Section 4.9: Surge ImmunitySection 4.10: Conducted RF Immunity
Section 4: Formal Test Results
Section 2: Details relating to the Equipment Under TestSection 2.1: Equipment Under Test (EUT)
Section 2.3: Configuration Diagram/Photograph of EUT
Section 3: Test Results Summary
Section 3.2: Measurement Uncertainty
Section 4.1: Mains Port Conducted Emissions
Section 4.11: Dips & Interruptions
Section 3.1: Test Results Summary Table
Contents
Section 1.1: GeneralSection 1.2: Customer DetailsSection 1.3: Equipment Under Test (EUT)
Section 1: Overview
Section 2.2: Auxiliary Equipment (AE)
Section 4.8: EFT/Bursts
Section 4.2: Discontinuous Conducted EmissionsSection 4.3: Disturbance Power Emissions
Section 4.5: Mains HarmonicsSection 4.6: Voltage FluctuationsSection 4.7: Electrostatic Discharge
Section 5: Performance Criteria
Section 6: List of Abbreviations
Section 4.4: Radiated Emissions
R12-2468A issue 2 Page 2 of 25
Photograph 1: Disturbance power Setup
Table 1: Mains Harmonics Results
Annex A: Graphical Results
Annex C: Photographs
Graph 4: Disturbance Power Emissions - DC Cable - from EUT to PSUGraph 5: Disturbance Power Emissions - DC Cable - from PSU to EUT
Graph 1: Mains Port Conducted Emissions - Live TerminalGraph 2: Mains Port Conducted Emissions - Neutral TerminalGraph 3: Disturbance Power Emissions - Mains Cable
Annex B: Tabular Results
R12-2468A issue 2 Page 2 of 25
Section 1.1: General
Section 1: Overview
This test report contains details of testing carried out on sample(s) submitted to Kiwa BlackwoodCompliance Laboratories for an assessment against Electromagnetic Compatibility (EMC) standards inaccordance with an agreed Test Plan.
Opinions and interpretations where given in this test report are outside of the scope of our UKASAccreditation.
f
Section 1.2: Customer Details
Fully testing to a harmonised standards as listed in the Official Journal is the equivalent of the EMC Assessment and this gives a presumption of conformity to the EMC Directive 2004/108/EC. The customeris advised to keep up to date with changes to standards in the Official Journal which may affect thecompliance of the product.
This test report relates only to the specific items detailed in Section 1.3 and Section 2 as Equipment UnderTest (EUT). The results given in this report relate only to the tests, configurations, operation modes andarrangements of the EUT as defined within this report.
The results contained in this test report do not relate to any Auxiliary Equipment (AE) which has been usedto exercise, monitor and/or provide suitable loading for the EUT. AE, where applicable, is also detailed inSection 2.
Deviations from, additions to, or exclusions from the standard test method and, where applicable,information on specific test conditions, or where tests are not covered by our UKAS Accreditation schedule,are stated in the Results Summary Table in Section 3.1.
R12-2468A issue 2 Page 3 of 25
The equipment under test was a low carbon room cooling device with mains adaptor for use in areas with a volume of up to 100 cubic metres.
The device creates a high voltage direct current that is discharged in very short pulses through a spark gap and electrostatic emitter.
This test report was prepared for:
Tazla Energy Ltd491 High Street
Section 1.3: Equipment Under Test (EUT)
Harrow WealdMiddlesexHA3 6HL
R12-2468A issue 2 Page 3 of 25
Test Start Date:Test Completed Date:
Not ListedBuild State: ProductionCondition: GoodSoftware Version: N/A
Product Name:
Manufacturer:Description:Model No:
Build State:
Part No:
Section 2.2: Auxiliary Equipment (AE)
Section 2.3: Configuration Diagram/Photograph of EUT
Not applicable
Switching Mode Power SupplyManufacturer: MPWDescription: 9V 600mA Power SupplyModel No: GPE060A-090060-ZPart No: 981091143Serial No:
Section 2: Details relating to the Equipment Under Test
Low energy cooling deviceSPARKSMD V1.3Not Stated
Pre-production sampleGood
Not Stated
Product Name:
22 October 201208 November 2012
Section 2.1: Equipment Under Test (EUT)
Condition:
Serial No:
BeCoolaTazla Energy Ltd
Software Version:
R12-2468A issue 2 Page 4 of 25R12-2468A issue 2 Page 4 of 25
0 PassEFT/BurstsEN 55014-2:1997 + A1:2001 + A2:2008 ±1.0kV, Live, Neutral and Earth
0 Pass
EN 55014-1:2006 + A1:2009 + A2:2011* Household and similar products
Household and similar products
Pass0
Discontinuous Conducted Emissions
EN 55014-1:2006 + A1:2009 + A2:2011*
PassDisturbance Power
EmissionsEN 55014-1:2006 + A1:2009 + A2:2011* Household and similar products 0
Voltage Fluctuations
EN 61000-3-3:2008
Electrostatic Discharge
EN 55014-2:1997 + A1:2001 + A2:2008
0 Pass
0 Pass
Radiated EmissionsEN 55014-1:2006 + A1:2009 + A2:2011* Household and similar products 0
0 PassMains HarmonicsEN 61000-3-2:2006 + A1:2009* + A2:2009*
N/A
0
Pst/dc(%)/dmax(%)/d(t)
±4.0kV Contact/±8.0kV Air
Test Level/Frequency Range:
Section 3: Test Results Summary
Section 3.1: Test Results Summary Table
Test: Standard: Result:Mod.:
150kHz to 80MHz, 3V 80% AM 1kHzConducted RF
ImmunityEN 55014-2:1997 + A1:2001 + A2:2008
0 PassSurge ImmunityEN 55014-2:1997 + A1:2001 + A2:2008
Mains Port Conducted Emissions
±1.0kV Line to Line, ±2.0kV Line to Earth
Class A
Pass
R12-2468A issue 2 Page 5 of 25
Mod. (modification status):
All of the above tests are included on the Kiwa Blackwood UKAS accreditation schedule (No. 2667) except the amendments marked with *.
0 Pass
0
Dips & InterruptionsEN 55014-2:1997 + A1:2001 + A2:2008 >95%/60%/30%
The EUT was tested as received, i.e. with a ferrite attached to the DC Power Cable (Fair-rite 2643102002) as shown in Section 2.3.
y
R12-2468A issue 2 Page 5 of 25
With regard to other Immunity tests the calibration parameters of the test equipment meet the basic standard requirement for tolerances even when extended by the calibration uncertainty.
With regard to emissions testing Ulab meets Ucispr meaning that a simple pass or fail is reported.
With regard to Radiated Field Immunity and Conducted RF Immunity testing the test level generation uncertainty has not been added to the test level. It is therefore only possible to state that the test level was achieved with a 50% level of confidence. This is in line with current Cenelec interpretation sheets on the two basic standards EN 61000-4-3 and EN 61000-4-6.
ISO/IEC 17025:2005 “General requirements for the competence of testing and calibration laboratories” requires measurement uncertainty to be estimated for all testing done.
Section 3.2: Measurement Uncertainty
Measurements Uncertainty for conducted and radiated emissions has been calculated and applied in accordance with CISPR 16-4-2:2003. Measurement Uncertainty has been calculated for all other tests in accordance with UKAS document LAB 34 Edition 1:2002.
R12-2468A issue 2 Page 6 of 25R12-2468A issue 2 Page 6 of 25
Test Equipment Used:
Regavolt Type 708 RegaSafe Variac85218523
150 kHz to 30 MHz
Mains Port Conducted Emissions
Frequency Range:
Section 4.1: Mains Port Conducted Emissions
EN 55014-1:2006 + A1:2009 + A2:2011*
8627 Telegartner J01006A0836 10dB AttenuatorFluke 73 series Multimeter
8501 EMCO 3825/2 Line Impedance Stabilisation Network
Section 4: Formal Test Results
Operation Mode: The EUT was powered up and operating throughout the test.
Test Standard:
AMN
Mains port
EUTto Measuring Receiver
Horizontal Ground Plane
Vertical Ground
Plane
0.8m
0.4m
R12-2468A issue 2 Page 7 of 25
Below are the worst case mains port conducted emissions:
Additional Comments:
Test Results:
8657 50Ω Termination
Level (dB(V)): Limit (dB(V)):
8513 HP8568B Spectrum Analyser System
8525 Ladybird Nightlight
4.0365656 -9.7L QP
4.369L QP
QP 3.993
Av
Terminal: Detector:Frequency
(MHz):
Oregon Scientific BAA898HG Environmental Monitor
HP Conducted Emissions Software
Margin (dB):Mains Voltage
(Vac):Result:
46.3
46.3 56-9.7
0.3214 35.256
3.9356 -9.4230Vac
QP
8636
8508 10m BNC cable8627 Telegartner J01006A0836 10dB Attenuator
230Vac46.6
230Vac 4.755230Vac L
8648
-9.7 Pass
PassPass
Pass230Vac L
None.
L QP
46.3
230Vac LPass-9.746.3
50.7 -15.5 Pass
R12-2468A issue 2 Page 7 of 25
Test Equipment Used:
Operation Mode:
85218627
Test Standard:
EMCO 3825/2 Line Impedance Stabilisation Network
Discontinuous Conducted Emissions
Frequency Range:
Telegartner J01006A0836 10dB Attenuator10m BNC cable
The EUT was powered and operating throughout the test.
EN 55014-1:2006 + A1:2009 + A2:2011*
Section 4.2: Discontinuous Conducted Emissions
150 kHz to 30 MHz
85018523 Regavolt Type 708 RegaSafe Variac
Fluke 73 series Multimeter
8657 50Ω Termination8508
AMN
Mains port
EUT to Discontinuous Interference Analyser
Horizontal Ground Plane
Vertical Ground
Plane
0.8m
0.4m
R12-2468A issue 2 Page 8 of 25
Additional Comments:
- - --
Pass-
30 Quasi-Peak - -- -
0.15 Quasi-Peak0.51.4 Quasi-Peak
Quasi-Peak- -
Pass
Time (min):No of clicks
over Limit, L:
85138636
Oregon Scientific BAA898HG Environmental Monitor
Test Results:
Result:Relaxed Limit, Lq (dB(V)):
No of clicks over Lq:
HP8568B Spectrum Analyser System
Limit, L (dB(V)):
HP Conducted Emissions Software
Frequency (MHz):
Detector:
Pass-
-
--- -- Pass
-
-
Discontinuous conducted emissions were manually observed at 0.15 MHz and 0.5 MHz. They were observed as not exceeding the continuous conducted emissions limits.
8648
R12-2468A issue 2 Page 8 of 25
Test Equipment Used:
30 MHz to 300 MHzEN 55014-1:2006 + A1:2009 + A2:2011*
Fluke 73 series Multimeter
Test Standard:
Operation Mode:
Chase CEC8110 Ferrite Absorbing Clamp8651A Telegartner J01006A0835 6dB Attenuator
Frequency Range:
Disturbance Power Measurement Set Up
Section 4.3: Disturbance Power Emissions
The EUT was powered and operating during the test.
10m BNC cableHP8568B Spectrum Analyser System8512
8523 Regavolt Type 708 RegaSafe Variac8521
8651B
8651
Ferrite
Measuring Clamp
EUT
Cable Under Test
to Measuring Receiver
>6.0m
R12-2468A issue 2 Page 9 of 25
Below are the top six recorded worst case disturbance power emissions:
Additional Comments:
PSU to EUT
45.240.1
230Vac
Frequency (MHz):
Test Results:
44.4 45.1230Vac
QP 44.77QP
Result:
40.2 -5.4-5.5
Pass
QPQP
-3.7
Mains Voltage (Vac):
Limit (dBpW):
230VacPSU to EUT -5.1
34.84 45.241.5 45.2230Vac
Margin (dB):
Pass65.13
None.
PassQP 32.89 -0.7
Detector:
39.940.7
p y y
230Vac
EUT to PSU
-3.6230Vac QP
35.81
Cable Under Test:
41.6
QPQPQP
41.1173.9144.87
Pass
HP Radiated Emissions Pre-scan SoftwareOregon Scientific BAA898HG Environmental Monitor
46.345.6
PSU to EUT
EUT to PSU
PassPass
39.7
45.446.645.6
-5.5-5.9-5.9
PassPassPass
34.36
Level (dBpW):
40.8
230Vac
MainsMains
86378648
230Vac230Vac Mains
EUT to PSU
R12-2468A issue 2 Page 9 of 25
Test Equipment Used:
Test Results:
Below are the top recorded worst case radiated emissions:
Section 4.4: Radiated Emissions
Maximisation of Radiated Emissions on OATS
None
Test Standard: EN 55014-1:2006 + A1:2009 + A2:2011*
Operation Mode: Not applicableFrequency Range: 30 MHz to 1000 MHz
Ground plane
Antenna Distance
EUT placed on Turntable Height scan
(1 m to 4 m)
to Measuring Receiver
10.0m
R12-2468A issue 2 Page 10 of 25
Additional Comments:
-H-
- N/A-
Antenna Polarisation:
Antenna Distance (m):
Detector:
V - - -----
The EUT had no clock frequencies >30MHz and meets the requirements of clause 4.1.2.3.2 and figure 10 of EN 55014-1:2006 + A1:2009, therefore this test is not required.
- N/A
Level (dB(V/m)):
Limit (dB(V/m):
Margin (dB): Result:Frequency
(MHz):
R12-2468A issue 2 Page 10 of 25
Test Equipment Used:
8693
Operation Mode:
A
8675
Voltech IEC555 Reference Impedance Network (short-circuited)
Section 4.5: Mains Harmonics
Mains Harmonics
Mains Voltage:
Test Standard: EN 61000-3-2:2006 + A1:2009* + A2:2009*
Test Method: Assessed by fluctuating harmonics over 2.5 minutesClass:
230Vac
8562
100 Hz to 2.0 kHz
Voltech PM6000 Power AnalyserSchaffner NSG1007 5 InterHarmonics Po er So rce
Frequency Range:The EUT was powered up and operating throughout the test.
0º 180º 360º 0º 180º 360º
Example current waveform
which comprises of a fundamental
and its harmonics
R12-2468A issue 2 Page 11 of 25
The test was performed more than once in order to obtain a repeatability of the result within ±5%.
Additional Comments:
yes
Test Results:
IEC1000-3 Software Release 3.11.078675
Repeatability achieved (Y/N): Result:
2.5 minutes 4.5
The power consumption of the EUT was <75W, therefore no limits apply.
Pass
8688
Power Consumption (W):Test Observation Period:
Schaffner NSG1007-5 InterHarmonics Power Source
R12-2468A issue 2 Page 11 of 25
Test Equipment Used:
Schaffner NSG1007-5 InterHarmonics Power Source
Voltech PM6000 Power Analyser
Mains Voltage:
8675
230Vac
Operation Mode: The EUT was switched on at 1 minute and was then operating for alternate minutes during the test.
Section 4.6: Voltage Fluctuations
Test Standard:
8563
Relative Voltage Change Characteristic
8562 Voltech IEC555 Reference Impedance Network (open-circuited)
8688 IEC1000-3 Software Release 3.11.07
EN 61000-3-3:2008
d(t)dmax
dcU(t)Un
t1 t2 t3
R12-2468A issue 2 Page 12 of 25
Additional Comments:
0.16
None
Pass
1 Pass500 Pass
Parameter measured: Measured level: Limit:
0.142
Result:
3.3dc
Test Results:
Pst0
dmax 4 Passd(t)
0.005
R12-2468A issue 2 Page 12 of 25
Test Equipment Used:
B
Atmospheric Pressure (mb):
Temperature (C): 16.3
The EUT was powered up and operating during the test.
Observing:
Section 4.7: Electrostatic Discharge
Test Standard:
999
Basic Standard: EN 61000-4-2:1995 + A1:1998 + A2:2001
The "power on" light and the waveform output of the BeCoola was monitored throughout the test for any change.
Relative Humidity (%): 52
Performance Criteria:
Operation Mode:
EN 55014-2:1997 + A1:2001 + A2:2008
Electrostatic Discharge Current Waveform
90%
0.7 to 1.0ns
Current at 30ns
Current at 60ns
10%
100%
R12-2468A issue 2 Page 13 of 25
Additional Comments:
N/A
TesTec HVP-40 high voltage probe
N/A OKContact N/A
-8kV
OK
N/A
8015
N/A
Test Results:
OK
Teseq NSG434 ESD Simulator
N/A N/A
OK
Vertical Coupling Plane
HCP PassN/A
+6kV -6kV
N/A
OK
Fluke 123 scopemeter
Contact VCP N/A
Contact N/A
N/A
N/A
+4kV -4kV
N/AOK
+8kV Result:
Oregon Scientific BAA898HG Environmental Monitor
N/A
8082
N/A
Horizontal Coupling Plane
8648
-2kVApplied to: +2kV
-
8709-
N/A
Sides OK Pass
Pass
PassN/AAir N/ATopN/A OK
N/A N/A OKN/A
Pass
N/A
N/A N/AN/A
OKN/AAir N/APSU N/AN/AN/A OKN/A
None.
N/A
PassOK
N/A
DC input
Air
Contact or Air Discharge?
N/A
R12-2468A issue 2 Page 13 of 25
Test Equipment Used:
Test Duration:
52
Performance Criteria: B
Section 4.8: EFT/Bursts
Test Standard: EN 55014-2:1997 + A1:2001 + A2:2008Basic Standard:
The "power on" light and the waveform output of the BeCoola was monitored throughout the test for any change.
Relative Humidity (%):Atmospheric Pressure (mb):
2.0 minutes
16.3
999
Temperature (C):
EN 61000-4-4:2004
EFT/Bursts Voltage Waveform
Operation Mode: The EUT was powered up and operating during the test.
Observing:
EFT repeated within Burst at a rate of 5kHz
50%
90%
10%
300ms
15ms
5ns
50ns
Fast Transients Bursts
R12-2468A issue 2 Page 14 of 25
Test Equipment Used:
Observations:
Additional Comments:
Obs 1
Port Under Test:
Test Results:
+1kV
N/A
85558638
Result:
Schaffner WIN2025 EFT/Bursts SoftwareSchaffner NSG2025 Transient Generator
-0.5kV
Obs1N/A
-1kV
801580828648
Fluke 123 scopemeterTesTec HVP-40 high voltage probeOregon Scientific BAA898HG Environmental Monitor
None.
-2kV
PassN/AObs1LNE
+0.5kV
N/A
During application of the phenomena the waveshape output was intermittent. The normal waveshape was self-recovering once the test was completed. The "power on" light remained lit throughout the test.
+2kV
R12-2468A issue 2 Page 14 of 25
Test Equipment Used:
B
Observing:
19.6Performance Criteria:
Operation Mode:
Temperature (C):
1001
EN 61000-4-5:2006
Surge Open Circuit Voltage Waveform
Relative Humidity (%):
EN 55014-2:1997 + A1:2001 + A2:2008
Section 4.9: Surge Immunity
Test Standard:
42Atmospheric Pressure (mb):
Basic Standard:The EUT was powered up and operating during the test.The "power on" light and the waveform output of the BeCoola was monitored throughout the test for any change.
90%
50%
30%1.2 μs± 30%
<30%50 μs ± 20%
R12-2468A issue 2 Page 15 of 25
Additional Comments:
9 μF
90N-E
12 Ω
N/A
12 Ω N/A N/A12 Ω 9 μF270
N/AN/A
N/A
N/A
N-E 27012 Ω 9 μF
N/AN/A
N/A
N/A N/A N/A
N/A
N/APass
N/AN/A
N/A
N/A
N/A
N/AN/A
Pass
N/AN/A N/A
N/A
N/A
9 μF
L-EN-E 0
12 Ω
None.
N/AN/A
N/A N/AN/A
N/AN/A N/A
N/AN/A N/A
N/AN/A
R
18 μF
+0.5kV
0 2 Ω
8648
Test Results:
C
N/A N/AL-N+2kV
9 μF
-0.5kV +1kV -1kV
0
8015 Fluke 123 scopemeterTeseq NSG30408715
L-EN/A
Oregon Scientific BAA898HG Environmental Monitor
L-E
N/A N/A
90
2 Ω 18 μF
9 μF
18 μF2 Ω
N/A
N/A
N/A
N/AN/A
N/A OK N/AN/A
OKN/A
N/AN/A
N/A
90
N/A
L-N
12 ΩL-N 270
N/A-2kVφ Angle:Applied:
TesTec HVP-40 high voltage probe8082
Result:
R12-2468A issue 2 Page 15 of 25
Basic Standard: EN 61000-4-6:2007 + Corr 2007
Observing:The "power on" light and the waveform output of the BeCoola was monitored throughout the test for any change.
Frequency Range: 0.15 MHz to 230 MHz
3.0 s1.0 %
Performance Criteria:Temperature (C): 19.6
Test Level: 3.0 V (RMS)80 % Amplitude Modulation with 1.0 kHz sine wave
Amplitude Modulation with 1kHz sinewave at 80% depth
A
Test Standard:
Relative Humidity (%): 42
Modulation:
Section 4.10: Conducted RF Immunity
Dwell time:
EN 55014-2:1997 + A1:2001 + A2:2008
Operation Mode: The EUT was powered up and operating throughout the test.
Frequency Step Rate:
Carrier Wave Peak Level
80%
80%
1kHz
R12-2468A issue 2 Page 16 of 25
Test Equipment Used:
Additional Comments:
Observed effect on EUT: Result:
TesTec HVP-40 high voltage probeEMC Hire Conducted Immunity SoftwareOregon Scientific BAA898HG Environmental Monitor
Bird 25-A-MFB-10 10dB Attenuator
No malfunctions observed Pass
Port Under Test:
Test Results:
RF coupled via:
87228531 AR 25A250 RF Amplifier
Associated CablesFluke 123 scopemeter
8527 HP8567A Signal Generator
8677-
Schaffner CDN-M2-16 Coupling / Decoupling Network
Mains M2
8015808286358648
None.
R12-2468A issue 2 Page 16 of 25
Test Equipment Used:
Test Standard: EN 55014-2:1997 + A1:2001 + A2:2008
52
The "power on" light and the waveform output of the BeCoola was monitored throughout the test for any change.
Performance Criteria: CMains Voltage:
Atmospheric Pressure (mb):
230Vac
Observing:
The EUT was powered up and operating during the test.
Dips & Interruptions
Temperature (C): 16.3Relative Humidity (%):
999
Operation Mode:Basic Standard: EN 61000-4-11:2004
Section 4.11: Dips & Interruptions
Duration
Percentage Drop
R12-2468A issue 2 Page 17 of 25
q p
Additional Comments:
80158082
Fluke 123 scopemeterTesTec HVP-40 high voltage probe
8648 Oregon Scientific BAA898HG Environmental Monitor
Pass30 25
No malfunctions observed.+ve 0.5>95
No malfunctions observed.
C
C
Teseq NSG3040
>95 -ve 0.5 Pass
Pass
Test Results:
8522 Beckman T100B Multimeter8524 Varatran Z710R Variac
8715
No malfunctions observed.
Performance Criteria:
Pass
No malfunctions observed.
None.
Percentage Drop:
Duration: Result:Observed effect on EUT:
C
C
60 10
R12-2468A issue 2 Page 17 of 25
Quasi-Peak Measurement DetectorAV A M t D t t
PK: Peak Measurement DetectorAE: Auxiliary Equipment (i.e. equipment connected to the EUT)EUT: Equipment Under Test
Section 5: Performance Criteria
Performance criterion C: Temporary loss of function is allowed, provided the function is self- recoverableor can be restored by the operation of the controls, or by any operation specified in the instructions for use.
Performance criterion A: The apparatus shall continue to operate as intended during the test. Nodegradation of performance or loss of function is allowed below a performance level (or permissible loss ofperformance) specified by the manufacturer, when the apparatus is used as intended. If the minimumperformance level or the permissible performance loss is not specified by the manufacturer, then either ofthese may be derived from the product description and documentation, and from what the user mayreasonably expect from the apparatus if used as intended.
Below is the performance criteria as expressed in EN 55014-2 EMC immunity standard.
Section 6: List of Abbreviations
Performance criterion B: The apparatus shall continue to operate as intended after the test. Nodegradation of performance or loss of function is allowed below a performance level (or permissible loss ofperformance) specified by the manufacturer, when the apparatus is used as intended. During the test,degradation of performance is allowed, however, no change of actual operating state or stored data isallowed. If the minimum performance level or the permissible performance loss is not specified by themanufacturer, then either of these may be derived from the product description and documentation, andfrom what the user may reasonably expect from the apparatus if used as intended.
QP:
R12-2468A issue 2 Page 18 of 25
L-N: Applied between Live and Neutral terminals
H: Horizontal PolarisationVertical Polarisation
L:AV: Average Measurement Detector
N-E: Applied between Neutral and Earth terminalsV:
Applied between Live and Earth terminals
N: Neutral TerminalE: Earth Terminal
L-E:
Live Terminal
R12-2468A issue 2 Page 18 of 25
Annex A: Graphical Results
Graph 1: Mains Port Conducted Emissions - Live Terminal
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bu V]
. 1 5 1 1 0 3 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Conduc t ed
12- 2468A BeCool a L I VE TERMI NAL
2 2 Oc t 2 0 1 2 1 5 : 3 2 : 4 4Ki wa Bl a c k wo o d
QUASI - PEAK
AVERAGE
R12-2468A issue 2 Page 19 of 25R12-2468A issue 2 Page 19 of 25
Graph 2: Mains Port Conducted Emissions - Neutral Terminal
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bu V]
. 1 5 1 1 0 3 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Conduc t ed
12- 2468A BeCoo l a NEUTRAL TERMI NAL
2 2 Oc t 2 0 1 2 1 3 : 5 2 : 3 6Ki wa Bl a c k wo o d
QUASI - PEAK
AVERAGE
R12-2468A issue 2 Page 20 of 25R12-2468A issue 2 Page 20 of 25
Graph 3: Disturbance Power Emissions - Mains Cable
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bp W]
3 0 1 0 0 3 0 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Di s t . Power
12- 2468A BeCool a MAI NS CABLE
2 2 Oc t 2 0 1 2 1 0 : 1 7 : 3 0BL ACKWOOD L ABS
QUASI - PEAK
AVERAGE
R12-2468A issue 2 Page 21 of 25R12-2468A issue 2 Page 21 of 25
Graph 4: Disturbance Power Emissions - DC Cable - from EUT to PSU
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bp W]
3 0 1 0 0 3 0 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Di s t . Power
12- 2468A BeCool a DC CABLE EUT TO PSU
2 2 Oc t 2 0 1 2 1 1 : 3 8 : 4 0BL ACKWOOD L ABS
QUASI - PEAK
AVERAGE
R12-2468A issue 2 Page 22 of 25R12-2468A issue 2 Page 22 of 25
Graph 5: Disturbance Power Emissions - DC Cable - from PSU to EUT
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bp W]
3 0 1 0 0 3 0 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Di s t . Power
12- 2468A BeCoo l a DC CABLE PSU TO EUT
2 2 Oc t 2 0 1 2 1 2 : 5 0 : 4 7BL ACKWOOD L ABS
QUASI - PEAK
AVERAGE
PEAK QUASI - PEAK AVERAGE
FREQUENCY [ MHz ]
EMI SSI ON L EVEL [ d Bp W]
3 0 1 0 0 3 0 0
2 0
4 0
6 0
8 0
1 0 0EN 55014 HOUSEHOLD Di s t . Power
12- 2468A BeCoo l a DC CABLE PSU TO EUT
2 2 Oc t 2 0 1 2 1 2 : 5 0 : 4 7BL ACKWOOD L ABS
QUASI - PEAK
AVERAGE
R12-2468A issue 2 Page 23 of 25R12-2468A issue 2 Page 23 of 25
Annex B: Tabular Results
Table 1: Mains Harmonics Results
R12-2468A issue 2 Page 24 of 25R12-2468A issue 2 Page 24 of 25
Annex C: Photographs
Photograph 1: Disturbance power Setup
R12-2468A issue 2 Page 25 of 25
End of Report
R12-2468A issue 2 Page 25 of 25