Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 1 of 22
EMC TEST REPORT
EN 301 489-1
Electromagnetic Compatibility for radio equipment and services
EN 301 489-19
ElectroMagnetic Compatibility (EMC) for Receive Only Mobile Earth Stations (ROMES) operating in the 1,5 GHz band providing data communications and GNSS receivers operating in the RNSS band
(ROGNSS) providing positioning, avigation, and timing data
EN 301 489-52
Electromagnetic Compatibility for radio equipment and services - Specific conditions for Cellular Communication
Mobile and portable radio and ancillary equipment
Report Reference No. ..................... : G0M-1708-6809-EE01RE-V01
Testing Laboratory ......................... : Eurofins Product Service GmbH
Address ............................................. : Storkower Str. 38c
15526 Reichenwalde
Germany
Accreditation……………………...…..: DAkkS - Registration number : D-PL-12092-01-02
Applicant’s name ............................ : FALCOM GmbH
Address ............................................. : Gewerbering 6
98704 Langewiesen
GERMANY
Test specification:
Standard ........................................... : EN 301 489-1 V2.2.0:2017-03 (Draft)
EN 301 489-1 V2.1.1:2016-11 (Final draft)
EN 301 489-19 V2.1.0:2017-03 (Draft)
EN 301 489-52 V1.1.0:2016-11 (Draft)
Non-standard test method…………..: None
Test scope………….. ........................ : partial EMC compliance test
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 2 of 22
Equipment under test (EUT):
Product description. .......................... : Tracking Solution
Model No. ......................................... : FOX3
Additional Models ............................. : None
Hardware Version ............................. : Rev02c
Software / Firmware Version ............ : avl_2.12.0_rc17
Test result Passed
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 4 of 22
Version History
Version Issue Date Remarks Revised by
V01 2017-09-15 Initial Release
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 5 of 22
REPORT INDEX
1 EQUIPMENT (TEST ITEM) DESCRIPTION 6
1.1 Equipment photos 7
1.2 Input / Output Ports 10
1.3 Supporting Equipment Used During Testing 10
1.4 Test Equipment Used During Testing 11
1.5 EUT Operation Modes 12
1.6 Immunity Performance Criteria 13
2 RESULT SUMMARY 20
3 TEST CONDITIONS AND RESULTS 21
3.1 Test Conditions and Results – Immunity to RF electromagnetic fields 21
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 6 of 22
1 Equipment (Test item) Description
Description Tracking Solution
Model FOX3
Additional Models None
Serial number None
Hardware version Rev02c
Software version avl_2.12.0_rc17
Manufacturer
FALCOM GmbH
Gewerbering 6
98704 Langewiesen
GERMANY
Ratings / Power supply 12V DC
Number of tested samples 1
Protective Earth / Ground No
Functional Earth No
Equipment classification Final draft EN 301 489-1 V2.2.0 /V2.1.1
Ancillary equipment : No Equipment use : Portable Mobile Fixed Equipment location : General Public Equipment Class : Class B Equipment type : Tabletop Internal frequency : 1900 MHz
Equipment classification EN 301 489-19 V2.1.0
Radio type : Receiver only Radio Technology : GNSS Radio frequency range : 1575 MHz
Equipment classification EN 301 489-52 V1.1.0
Radio type : Transceiver Radio Technology : GSM/GPRS900/1800 Equipment type : without analogue speech
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 7 of 22
1.1 Equipment photos
EUT Top
EUT Botom
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 8 of 22
EUT Connector
EUT USB Connector
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 9 of 22
EUT PCB Top
EUT PCB Botom
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 10 of 22
1.2 Input / Output Ports
Port # Name Type* Max. Cable
Length Cable
Shielded Comments
1 DC Power DC unspecified no
2 Audio Interface I/O unspecified no Not tested
3 Accessory Port I/O 1.5m no
4 RS232 I/O 1.5m no
5 USB I/O unspecified yes Service only not tested
6 GNSS Antenna Port I/O 2.5m yes
7 GSM Antenna Port I/O 2.5m yes
*Note: Use the following abbreviations:
AC : AC power port
DC : DC power port
N/E : Non electrical
I/O : Signal input or output port
TP : Telecommunication port
1.3 Supporting Equipment Used During Testing
Product Type*
Device Manufacturer Model No. Comments
SIM Communication tester Rohde & Schwarz CMU 200
AE Laptop Dell Latitude E6420 S/N CXJ43R1
AE GSM/GPS Antenna Falcom GmbH FAL-ANT-11
AE Software Falcom Workbench 2.7.2-RC1
*Note: Use the following abbreviations:
AE : Auxiliary/Associated Equipment, or
SIM : Simulator (Not Subjected to Test)
CABL : Connecting cables
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 11 of 22
1.4 Test Equipment Used During Testing
Measurement Software
Description Manufacturer Name Version
EMC Test Software Dare!! Instruments Radimation 2016.1.10
Radiated immunity
Description Manufacturer Model Identifier Cal. Date Cal. Due
RF generator R&S SMB100A EF00823 2017-02 2018-02
RF Amplifier Milmega AS0104-400/200
EF00376 System
calibration System
calibration
RF Amplifier Teseq CBA1G-1000 EF00382 System
calibration System
calibration
RF Amplifier Amplifier Research
TWT 200T4G8 EF00802 System
calibration System
calibration
Antenna Frankonia BTA-H EF00294 System
calibration System
calibration
X-Wing BiLog-Antenna
TESEQ GmbH CBL 6144 EF01190 System
calibration System
calibration
Horn antenna Schwarzbeck BBHA 9120D EF00018 2016-09 2019-09
Power meter R&S NRVD EF00401 2017-07 2020-07
Power Sensor R&S NRV-Z1 EF00314 2017-07 2019-07
Power Sensor R&S NRV-Z1 EF00315 2017-07 2019-07
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 12 of 22
1.5 EUT Operation Modes
Mode # Description
1 EUT powered up. GSM 900: GPRS 1 slot; Ch.: 62, gamma: 3. GNSS receive local position, RS232 communication with Laptop
2 EUT powered up. GSM 1800: GPRS 1 slot; Ch.: 697, gamma: 3. GNSS receive local position, RS232 communication with Laptop
3 EUT Power up, GSM/GPRS Standby, RS232 communication with Laptop
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 13 of 22
1.6 Immunity Performance Criteria
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. Definition related to the performance level:
based on the used product standard based on the declaration of the manufacturer, requestor or purchaser
Criterion for continuous phenomena according to EN 301 489-1:
Mode Acceptable level of performance
Transmitter (CT) Receiver (CR)
If no further details are given in the relevant part of ETSI EN 301 489 series dealing with the particular type of radio equipment, the following general performance criteria for continuous phenomena shall apply. During and after the test, the equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer when the equipment is used as intended. In some cases this permissible performance level may be replaced by a permissible loss of performance. During the test the EUT shall not unintentionally transmit or change its actual operating state and stored data. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be deduced from the product description and documentation and what the user may reasonably expect from the equipment if used as intended.
Criterion for transient phenomena according to EN 301 489-1:
Mode Acceptable level of performance
Transmitter (TT) Receiver (TR)
If no further details are given in the relevant part of ETSI EN 301 489 series [i.13] dealing with the particular type of radio equipment, the following general performance criteria for transient phenomena shall apply. For surges applied to symmetrically operated wired network ports intended to be connected directly to outdoor lines the following criteria applies:
For products with only one symmetrical port intended for connection to outdoor lines, loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer's instructions. A SW reboot is not allowed. Information stored in non-volatile memory, or protected by a battery backup, shall not be lost.
For products with more than one symmetrical port intended for connection to outdoor lines, loss of function on the port under test is allowed, provided the function is self-recoverable. A SW reboot is not allowed. Information stored in non-volatile memory, or protected by a battery backup, shall not be lost.
For all other ports the following applies:
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 14 of 22
After the test, the equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed below a permissible performance level specified by the manufacturer, when the equipment is used as intended. In some cases this permissible performance level may be replaced by a permissible loss of performance.
During the EMC exposure to an electromagnetic phenomenon, a degradation of performance is, however, allowed. No change of the actual mode of operation (e.g. unintended transmission) or stored data is allowed.
If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be deduced from the product description and documentation and what the user may reasonably expect from the equipment if used as intended.
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 15 of 22
For a voltage dip the following performance criteria apply:
for transmitters the performance criteria for transient phenomena for transmitter shall apply (see clause 6 of the relevant part of ETSI EN 301 489 series dealing with the particular type of radio equipment)
for receivers the performance criteria for transient phenomena for receiver shall apply (see clause 6 of the relevant part of ETSI EN 301 489 series dealing with the particular type of radio equipment)
for ancillary equipment the pass/failure criteria supplied by the manufacturer (see clause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply
For a voltage interruption the following performance criteria apply:
in the case where the equipment is fitted with or connected to a battery back-up, the performance criteria for transient phenomena for transmitters or for receivers shall apply (see clause 6 of the relevant part of ETSI EN 301 489 series dealing with the particular type of radio equipment)
in the case where the equipment is powered solely from the AC mains supply (without the use of a parallel battery back-up) volatile user data may have been lost and if applicable the communication link need not to be maintained and lost functions should be recoverable by user or operator
no unintentional responses shall occur at the end of the test
in the event of loss of function(s) or in the event of loss of user stored data, this fact shall be recorded in the test report
for ancillary equipment the pass/failure criteria supplied by the manufacturer (see clause 6.4) shall apply, unless the ancillary equipment is tested in connection with a receiver or transmitter in which case the corresponding performance criteria above shall apply
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 16 of 22
General criteria according to EN 301 489-19: The EUT, for all immunity tests according to the present document, except the spot frequency test of the immunity test with radiated RF electromagnetic fields, shall be assessed for: - the storage of messages in the memory of the EUT at the start of the test - unintentional responses of the EUT during the test - the maintenance of the EUT memory assessed at the conclusion of the test - the ability to receive and store messages at the conclusion of the test
For the spot frequency test of the immunity test with radiated RF electromagnetic fields the EUT shall be assessed by monitoring the accuracy of the call received alert signal Criteria for continuous phenomena applied to receivers according to EN 301 489-19: For the EUT: - the general performance criteria - during the test no false calls shall occur - at the conclusion of the test comprising the series of individual exposures, the EUT shall operate
as intended with no loss of function and/or stored data (messages), as declared by the manufacturer.
For the spot frequency test of the immunity test with radiated RF electromagnetic fields the EUT shall be assessed by monitoring the accuracy of the call received alert signal Criteria for transient phenomena applied to receivers according to EN 301 489-19: For the EUT: - the general performance criteria - during the test no false calls shall occur - at the conclusion of the test comprising the series of individual exposures, the EUT shall operate
as intended with no loss of function and/or stored data (messages), as declared by the manufacturer.
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 17 of 22
Criterion for continuous phenomena according to EN 301 489-52 GSM and DCS: The establishment and maintenance of a communications link, the assessment of RXQUAL, and the assessment of the audio breakthrough by monitoring the speech output signal level, are used as performance criteria to ensure that all primary functions of the transmitter and receiver are evaluated during the immunity tests. In addition, the test shall also be performed in idle mode to ensure the transmitter does not unintentionally operate.
Mode Acceptable level of performance
Transmitter (CT) A communication link shall be established at the start of the test, and maintained during the test. During the test, the uplink speech output level shall be at least 35 dB less than the previously recorded reference levels, when measured through an audio band pass filter of width 200 Hz, centred on 1 kHz (audio breakthrough check). At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate.
Receiver (CR) A communications link shall be established at the start of the test. During the test, the RXQUAL of the downlink shall not exceed the value of three, measured during each individual exposure in the test sequence. During the test, the downlink speech output level shall be at least 35 dB less than the previously recorded reference levels, when measured through an audio band pass filter of width 200 Hz, centred on 1 kHz (audio breakthrough check). At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained.
Criterion for transient phenomena according to EN 301 489-52 GSM and DCS:
Mode Acceptable level of performance
Transmitter (TT) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate.
Receiver (TR) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained.
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 18 of 22
Criterion for continuous phenomena according to EN 301 489-52 CDMA Direct Spread (UTRA and E-UTRA): The maintenance of a communications link shall be assessed by using an indicator, which may be part of the test system or the equipment under test. In addition, the test shall also be performed in idle mode to ensure the transmitter does not unintentionally operate.
Acceptable level of performance
A communication link shall be established at the start of the test, and maintained during the test. In the speech mode, the performance criteria shall be that the Up Link and Down Link speech output levels shall be at least 35 dB less than the recorded reference levels, when measured through an audio band pass filter of width 200 Hz, centred on 1 kHz. At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained. In addition to confirming the above performance in traffic mode, the test shall be performed in idle mode, and the transmitter shall not unintentionally operate. UTRA:
In the data transfer mode, the performance criteria can be one of the following:
if the BER (as referred in ETSI TS 134 109 [4]) is used, it shall not exceed 0,001 during the test sequence;
if the BLER (as referred in ETSI TS 134 109 [4]) is used, it shall not exceed 0,01 during the test sequence. The BLER calculation shall be based on evaluating the CRC on each transport block. E-UTRA:
In the data transfer mode, the performance criteria shall be that the throughput shall be ≥ 95 % of the maximum throughput of the reference measurement channel as specified in annex C in ETSI TS 136 101 [9] with parameters specified in tables 7.3.1-1 and 7.3.1-2 in ETSI TS 136 101 [9] during the test sequence.
Criterion for transient phenomena according to EN 301 489-52 CDMA Direct Spread (UTRA and E-UTRA):
Acceptable level of performance
A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained. In addition to confirming the above performance in traffic mode, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate.
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 19 of 22
Monitored parameters
Monitored value / parameter
Criteria
RS232 Communication GNSS Receive
Reconnection should be possible
GSM Connection During the test no interruptions in the GSM connection
Monitoring setup
Visual inspection of the connected Laptop with monitoring software. Visual inspection of the connected CMU with the EUT
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 20 of 22
2 Result Summary
EN 301 489-52, EN 301 489-1
Product Specific Standard
Requirement – Test Reference
Method Result Remarks
EN 301 489-52 Section 7.1
Radiated emissions of enclosure of ancillary equipment measured on a standalone basis
EN 55032:2015 N/A
EN 301 489-52 Section 7.1
Conducted emissions EN 55032:2015 N/T
EN 301 489-52 Section 7.1
Harmonic current emissions EN 61000-3-2:2006 + A1:2009 + A2:2009
N/A See EN 61000-3-2
section 7
EN 301 489-52 Section 7.1
Voltage fluctuations and flicker EN 61000-3-3:2013 N/A See EN 61000-3-3
section 6.1
EN 301 489-52 Section 7.1.2
Radio frequency electromagnetic field EN 61000-4-3:2006 + A1:2008 + A2:2010
PASS
EN 301 489-52 Section 7.1.2
Radio frequency, common mode EN 61000-4-6:2009 N/T
EN 301 489-52 Section 7.1.2
Electrostatic discharge EN 61000-4-2:2009 N/A
EN 301 489-52 Section 7.1.2
Fast transients, common mode EN 61000-4-4:2012 N/A
EN 301 489-52 Section 7.2
Transients and surges in the vehicular environment
ISO 7637-2:2011 N/T
EN 301 489-52 Section 7.1.2
Surges EN 61000-4-5:2006 N/A
EN 301 489-52 Section 7.1.2
Voltage dips and interruptions EN 61000-4-11:2004 N/A
Remarks:
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 21 of 22
3 Test Conditions and Results
3.1 Test Conditions and Results – Immunity to RF electromagnetic fields
Immunity to RF electromagnetic fields acc. to EN 301 489-19/ -52 Verdict: PASS
Laboratory Parameters: Required prior to the test During the test
Ambient Temperature 15 to 35°C 23°C
Relative Humidity 30 to 60% 45%
Test according to referenced standards
Common Part Reference Method
EN 301 489-1 EN 61000-4-3
Fully configured sample scanned over the following frequency range
Frequency range
80 MHz to 6 GHz
Samples tested on the following number of orientations
Number of orientations
4
EUT operating mode 1,2,3,
Test parameters and results
Frequency [MHz] Test level
[V/m] Modulation
Frequency step
Dwell time Result Criterion
80 – 1000 3 80 % AM 1 kHz 1 % 2 s PASS CT&CR
1000 – 6000 3 80 % AM 1 kHz 1 % 2 s PASS CT&CR
Test parameters and results – Spot frequencies acc. to EN 301 489-19
Frequency [MHz] Test level
[V/m] Modulation Dwell time Result Criterion
80 3 80 % AM 1 kHz 2 s PASS CR
104 3 80 % AM 1 kHz 2 s PASS CR
136 3 80 % AM 1 kHz 2 s PASS CR
165 3 80 % AM 1 kHz 2 s PASS CR
200 3 80 % AM 1 kHz 2 s PASS CR
260 3 80 % AM 1 kHz 2 s PASS CR
330 3 80 % AM 1 kHz 2 s PASS CR
430 3 80 % AM 1 kHz 2 s PASS CR
560 3 80 % AM 1 kHz 2 s PASS CR
715 ± 1 3 80 % AM 1 kHz 2 s PASS CR
920 ± 1 3 100 % Pulse 200 Hz
50 % Duty cycle 2 s PASS CR
Comments:
Test Report No.: G0M-1708-6809-EE01RE-V01
Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 22 of 22
Test Setup