emergency luminaires with batteries...3 emergency luminaires with batteries date of test high...

2
3 Emergency Luminaires with Batteries Date of Test high voltage: max. 500 V Charge time Test: min. 5 s 24.00 1 L N LL L NN N Log book No tie wrap 3 PHILIPS 2 2 B A A or B 1 B PHILIP 1 A PHILIP LL L NN N L N If needed, create a connection between N and NN“! Lifetime The batteries have a life time expectancy of 4 years when maintained properly. Replace after that time! Periodic testing Periodic tests should be performed according to EN50172: 2004, clause 7.2.3 and 7.2.4. Each month the driver is running in emergency mode for 30 seconds. Once a year a full discharge cycle of at least 1 hr or 3 hrs (depending on product installed) should be performed. The tests could be done by complete disconnection of the luminaire. Printed in Hungary Data subject to change without notice Keep for future reference: www.philips.com/lighting 444 316 013543 © 11 / 2018, Signify Holding All rights reserved 1/2

Upload: others

Post on 19-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emergency Luminaires with Batteries...3 Emergency Luminaires with Batteries Date of Test high voltage: max. 500V Charge time Test: min. 5 s 24.00 1 L N LL L NN N No tie wrap Log book

3

Emergency Luminaires with Batteries

Date of

Test high voltage: max. 500 V

Charge time

Test: min. 5 s

24.00

1

L

N

LLLNNN

Log bookNo tie wrap

3

PHILIPS

2

2

B

A

A or B

1

BPHILIP

1

APHILIP

LLLNNN

L

N

If needed, createa connection between“N and NN“!

Lifetime The batteries have a life time expectancy of 4 years when maintained properly. Replace after that time! Periodic testingPeriodic tests should be performed according to EN50172: 2004, clause 7.2.3 and 7.2.4.Each month the driver is running in emergency mode for 30 seconds.Once a year a full discharge cycle of at least 1 hr or 3 hrs (depending on product installed) should be performed.The tests could be done by complete disconnection of the luminaire.

Printed in HungaryData subject to change without noticeKeep for future reference: www.philips.com/lighting

444 316 013543© 11 / 2018, Signify Holding All rights reserved 1/2

Page 2: Emergency Luminaires with Batteries...3 Emergency Luminaires with Batteries Date of Test high voltage: max. 500V Charge time Test: min. 5 s 24.00 1 L N LL L NN N No tie wrap Log book

2/2

LED UnitsDuration Number of cells Nominal voltageUnit PowerManufacturer

7,2

V

7,2

V

400 lm

400 lm

2

1

3 h

1 h

3 W

3 W

TrustSight Basic L 20-95V 3W 3hrs KIT

TrustSight Basic L 20-95V 3W 1hr KIT

Philips

Philips

Philips TrustSight Pro L 20-95V 3W 3hrs KIT 3 W 3 h 2 7,2 V 400 lm

Philips TrustSight Pro L 20-95V 3W 1hr KIT 3 W 1 h 1 7,2 V 400 lm

Philips TrustSight DALI L 20-95V 3W 3hrs KIT 3 W 3 h 400 lm7,2 V2

Philips TrustSight DALI L 20-95V 3W 1hr KIT 3 W 1 h 1 7,2 V 400 lm

Replacement batteries

Test with included switch

2/2

400 lm