en301 489 test report - s3-ap-southeast-2.amazonaws.com · voltage fluctuations and flicker en...
TRANSCRIPT
EN301 489 Test Report
Product Name : 300Mbps Wi-Fi Range Extender
Model No. : TL-WA855RE
Applicant : TP-Link Technologies Co., Ltd.
Address : Building 24(floors1,3,4,5) and 28(floors1-4) Central
Science and Technology Park, Shennan Rd, Nanshan,
Shenzhen, China
Date of Receipt : Dec. 05, 2016
Test Date : Dec. 05, 2016 ~ Dec. 27, 2016
Issued Date : Dec. 30, 2016
Report No. : 16C2012E-RF-CE-P01V01
Report Version : V1.0
The test results relate only to the samples tested.The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF, CNAS or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 2 of 96
Test Report Cert i f icat ion
Issued Date : Dec. 30, 2016 Report No. : 16C2012E-RF-CE-P01V01
Product Name : 300Mbps Wi-Fi Range Extender
Applicant : TP-Link Technologies Co., Ltd.
Address : Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and
Technology Park, Shennan Rd, Nanshan, Shenzhen, China
Manufacturer : TP-Link Technologies Co., Ltd.
Address : Building 24(floors1,3,4,5) and 28(floors1-4) Central Science and
Technology Park, Shennan Rd, Nanshan, Shenzhen, China
Model No. : TL-WA855RE
Brand Name : TP-Link
EUT Voltage : AC 100-240V / 50-60Hz
Test Voltage : AC 230V / 50Hz
Applicable Standard : ETSI EN 301 489-1 V1.9.2 (2011-09)
ETSI EN 301 489-17 V2.2.1 (2012-09)
Test Result : Complied
Performed Location : Quietek Corporation - Suzhou EMC Laboratory
No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,215006,
Jiangsu,China
TEL: +86-512-62515088 / FAX: +86-512-62515098
Documented By :
(Adm. Specialist: Angila Zhang)
Reviewed By :
(Engineering Supervisor: Jack Zhang)
Approved By :
(Engineering Manager: Harry Zhao)
Report No.: 16C2012E-RF-CE-P01V01
Page: 3 of 96
Laboratory Information
We, QuieTek Corporation, are an independent EMC and safety consultancy that was established
the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed)
by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope:
The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site: http://www.quietek.com/english/about/certificates.aspx?bval=5 The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site: http://www.quietek.com/index_en.aspx If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected]
LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected]
Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,215006, Jiangsu,China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected]
Taiwan R.O.C. : BSMI, NCC, TAF
USA : FCC
Japan : VCCI
China : CNAS
Report No.: 16C2012E-RF-CE-P01V01
Page: 4 of 96
TABLE OF CONTENTS Description Page 1. General Information ...................................................................................................... 8
1.1. EUT Description .............................................................................................. 8
1.2. Mode of Operation ........................................................................................... 9
1.3. Tested System Details ..................................................................................... 9
1.4. Configuration of Tested System ..................................................................... 10
1.5. EUT Exercise Software .................................................................................. 11
2. Technical Test ............................................................................................................. 12
2.1. Summary of Test Result................................................................................. 12
2.2. List of Test Equipment ................................................................................... 13
2.3. Measurement Uncertainty.............................................................................. 17
2.4. Performance Criteria ..................................................................................... 19
3. Conducted emission ................................................................................................... 23
3.1. Test Specification ........................................................................................... 23
3.2. Test Setup ..................................................................................................... 23
3.3. Limit ............................................................................................................... 23
3.4. Test Procedure .............................................................................................. 25
3.5. Deviation from Test Standard ......................................................................... 26
3.6. Test Result ..................................................................................................... 27
3.7. Test Photograph ............................................................................................ 31
4. Radiated emission ...................................................................................................... 33
4.1. Test Specification ........................................................................................... 33
4.2. Test Setup ..................................................................................................... 33
4.3. Limit ............................................................................................................... 34
4.4. Test Procedure .............................................................................................. 35
4.5. Deviation from Test Standard ......................................................................... 37
4.6. Test Result ..................................................................................................... 38
4.7. Test Photograph ............................................................................................ 42
5. Harmonic current emissions ....................................................................................... 44
5.1. Test Specification ........................................................................................... 44
5.2. Test Setup ..................................................................................................... 44
5.3. Limit ............................................................................................................... 44
5.4. Test Procedure .............................................................................................. 46
5.5. Deviation from Test Standard ......................................................................... 46
5.6. Test Result ..................................................................................................... 47
5.7. Test Photograph ............................................................................................ 49
6. Voltage fluctuations and flicker ................................................................................... 50
6.1. Test Specification ........................................................................................... 50
Report No.: 16C2012E-RF-CE-P01V01
Page: 5 of 96
6.2. Test Setup ..................................................................................................... 50
6.3. Limit ............................................................................................................... 50
6.4. Test Procedure .............................................................................................. 51
6.5. Deviation from Test Standard ......................................................................... 51
6.6. Test Result ..................................................................................................... 52
6.7. Test Photograph ............................................................................................ 53
7. Electrostatic discharge ................................................................................................ 54
7.1. Test Specification ........................................................................................... 54
7.2. Test Setup ..................................................................................................... 54
7.3. Limit ............................................................................................................... 55
7.4. Test Procedure .............................................................................................. 55
7.5. Deviation from Test Standard ......................................................................... 55
7.6. Test Result ..................................................................................................... 56
7.7. Test Photograph ............................................................................................ 58
8. Radio frequency electromagnetic field ........................................................................ 61
8.1. Test Specification ........................................................................................... 61
8.2. Test Setup ..................................................................................................... 61
8.3. Limit ............................................................................................................... 61
8.4. Test Procedure .............................................................................................. 63
8.5. Deviation from Test Standard ......................................................................... 63
8.6. Test Result ..................................................................................................... 64
8.7. Test Photograph ............................................................................................ 66
9. Fast transients common mode ................................................................................... 67
9.1. Test Specification ........................................................................................... 67
9.2. Test Setup ..................................................................................................... 67
9.3. Limit ............................................................................................................... 67
9.4. Test Procedure .............................................................................................. 68
9.5. Deviation from Test Standard ......................................................................... 68
9.6. Test Result ..................................................................................................... 69
9.7. Test Photograph ............................................................................................ 71
10. Surges ...................................................................................................................... 72
10.1. Test Specification ........................................................................................... 72
10.2. Test Setup ..................................................................................................... 72
10.3. Limit ............................................................................................................... 72
10.4. Test Procedure .............................................................................................. 73
10.5. Deviation from Test Standard ......................................................................... 73
10.6. Test Result ..................................................................................................... 74
10.7. Test Photograph ............................................................................................ 76
Report No.: 16C2012E-RF-CE-P01V01
Page: 6 of 96
11. Radio frequency common mode ............................................................................... 77
11.1. Test Specification ........................................................................................... 77
11.2. Test Setup ..................................................................................................... 77
11.3. Limit ............................................................................................................... 78
11.4. Test Procedure .............................................................................................. 79
11.5. Deviation from Test Standard ......................................................................... 79
11.6. Test Result ..................................................................................................... 80
11.7. Test Photograph ............................................................................................ 82
12. Voltage dips and interruptions................................................................................... 83
12.1. Test Specification ........................................................................................... 83
12.2. Test Setup ..................................................................................................... 83
12.3. Limit ............................................................................................................... 84
12.4. Test Procedure .............................................................................................. 84
12.5. Deviation from Test Standard ......................................................................... 84
12.6. Test Result ..................................................................................................... 85
12.7. Test Photograph ............................................................................................ 89
13. Transients and surges .............................................................................................. 90
13.1. Test Specification ........................................................................................... 90
13.2. Test Setup ..................................................................................................... 90
13.3. Limit ............................................................................................................... 90
13.4. Test Procedure .............................................................................................. 90
13.5. Deviation from Test Standard ......................................................................... 91
13.6. Test Result ..................................................................................................... 91
14. Attachment ............................................................................................................... 92
EUT Photograph ............................................................................................ 92
Report No.: 16C2012E-RF-CE-P01V01
Page: 7 of 96
History of This Test Report
REPORT NO. VERSION DESCRIPTION ISSUED DATE
16C2012E-RF-CE-P01V01 V1.0 Initial Issued Report Dec. 30, 2016
Report No.: 16C2012E-RF-CE-P01V01
Page: 8 of 96
1. General Information
1.1. EUT Description
Product Name 300Mbps Wi-Fi Range Extender
Model No. TL-WA855RE
Brand Name TP-Link
Report No.: 16C2012E-RF-CE-P01V01
Page: 9 of 96
1.2. Mode of Operation
QuieTek has verified the construction and function in typical operation. All the test modes were
carried out with the EUT in normal operation, which was shown in this test report and defined as:
Test Mode
Emission Mode 1: Transmission Data
Immunity Mode 1: Transmission Data
Mode 2: Standby
1.3. Tested System Details
The types for all equipments, plus descriptions of all cables used in the tested system (including
inserted cards) are:
Product Manufacturer Model No. Serial No. Power Cord
1 Notebook DELL LATITUNE
3440 253KC12 Power by adapter
2 Notebook DELL Latitude E5450 C14MY52 Power by adapter
Report No.: 16C2012E-RF-CE-P01V01
Page: 10 of 96
1.4. Configuration of Tested System
Connection Diagram
Signal Cable Type Signal Cable Description
A LAN Cable Non-shielded, >10m
Report No.: 16C2012E-RF-CE-P01V01
Page: 11 of 96
1.5. EUT Exercise Software
1 Setup the EUT and simulators as shown on above.
2 Turn on the power of all equipments.
3 EUT communicates with the Notebook through WLAN.
4 Execute “Ping” function to communicate with the Notebook.
5 Start test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 12 of 96
2. Technical Test
2.1. Summary of Test Result
No deviations from the test standards
Deviations from the test standards as below description:
Emission
Performed Test Item Normative References Test
Performed Deviation
Conducted emission EN 55022:2010+AC:2011 Yes No
Radiated emission EN 55022:2010+AC:2011 Yes No
Harmonic current emissions EN 61000-3-2: 2014 Yes No
Voltage fluctuations and flicker EN 61000-3-3: 2013 Yes No
Immunity
Performed Test Item Normative References Test
Performed Deviation
Electrostatic discharge EN 61000-4-2: 2009 Yes No
Radio frequency
electromagnetic field
EN 61000-4-3: 2006+A1:2008+A2:2010 Yes No
Fast transients common mode EN 61000-4-4: 2012 Yes No
Surges EN 61000-4-5: 2014 Yes No
Radio frequency common mode EN 61000-4-6: 2014 Yes No
Voltage dips and interruptions EN 61000-4-11: 2004 Yes No
Transients and surges ISO 7637-2: 2011 N/A N/A
Report No.: 16C2012E-RF-CE-P01V01
Page: 13 of 96
2.2. List of Test Equipment Conducted emission at mains terminals and telecommunication ports / TR1 Instrument Manufacturer Model No. Serial No. Cali. Due DateEMI Test Receiver R&S ESCI 100906 2017.03.05 Two-Line V-Network R&S ENV216 101189 2017.07.16 Two-Line V-Network R&S ENV216 101044 2017.09.04 V-Network R&S ESH3-Z6 100898 2017.03.05 V-Network R&S ESH3-Z6 100249 2017.10.16 Current Probe R&S EZ-17 100678 2017.03.05 Impedance Stabilization Network
Teseq GmbH ISN T800 30306 2017.03.05
Impedance Stabilization Network
Teseq GmbH ISN T8-Cat6 29680 2017.03.05
50ohm Termination SHX TF2 07081402 2017.09.04 50ohm Termination SHX TF2 07081403 2017.09.04 50ohm Coaxial Switch Anritsu MP59B 6200464462 N/A Coaxial Cable Suhner RG 223 TR1-C1 2017.02.28 Temperature/Humidity Meter zhicheng ZC1-2 TR1-TH 2017.01.05
Radiated emission / AC1 Instrument Manufacturer Model No. Serial No. Cali. Due DateEMI Test Receiver R&S ESCI 100175 2017.09.04 EMI Test Receiver R&S ESCI 100726 2017.03.05 EMI Receiver Agilent N9038A MY51210196 2017.07.16 Preamplifier Quietek AP-025C CHM-0602008 2017.04.11 Preamplifier Quietek AP-025C CHM-0503006 2017.04.11 Bilog Antenna Schaffner CBL6112B 2931 2017.09.09 Bilog Antenna Schaffner CBL6112B 2933 2017.09.09 DRG Horn Antenna ETS-Lindgren 3117 00167055 2017.07.12 Coaxial Cable Huber+Suhner RG 214_U AC1-L 2017.10.10 Coaxial Cable Huber+Suhner RG 214_U AC1-R 2017.10.10 Temperature/Humidity Meter zhicheng ZC1-2 AC1-TH 2017.01.05
Radiated emission / AC2 Instrument Manufacturer Model No. Serial No. Cali. Due DateEMI Test Receiver R&S ESCI 100573 2017.03.05 Bilog Antenna Teseq GmbH CBL6112D 27611 2017.08.10 Coaxial Cable Huber+Suhner RG 214 AC2-C 2017.02.28 Temperature/Humidity Meter zhicheng ZC1-2 AC2-TH 2017.01.05
Radiated emission / AC3 Instrument Manufacturer Model No. Serial No. Cali. Due DateEMI Test Receiver R&S ESCI 100176 2017.09.04 Bilog Antenna Teseq GmbH CBL6112D 27613 2017.07.18 Coaxial Cable Huber+Suhner RG 214 AC3-C 2017.02.28 Temperature/Humidity Meter zhicheng ZC1-2 AC3-TH 2017.01.05
Report No.: 16C2012E-RF-CE-P01V01
Page: 14 of 96
Radiated emission / AC5 Instrument Manufacturer Model No. Serial No. Cali. Due DateEMI Receiver Agilent N9038A MY51210196 2017.07.16 Preamplifier Miteq NSP1800-25 1364185 2017.05.03 DRG Horn Antenna ETS-Lindgren 3117 00167055 2017.07.12 Coaxial Cable Huber+Suhner SUCOFLEX 106 AC5-C2 2017.02.28 Temperature/Humidity Meter zhicheng ZC1-2 AC5-TH 2017.01.05 Harmonic current emissions / TR1 Instrument Manufacturer Model No. Serial No. Cali. Due DatePower Analyzer California PACS-1 72419 2017.11.06 AC Power Source California 5001iX-208 56741 2017.11.06 Temperature/Humidity Meter zhicheng ZC1-2 TR1-TH 2017.01.05
Voltage fluctuation and flicker / TR1 Instrument Manufacturer Model No. Serial No. Cali. Due DatePower Analyzer California PACS-1 72419 2017.11.06 AC Power Source California 5001iX-208 56741 2017.11.06 Temperature/Humidity Meter zhicheng ZC1-2 TR1-TH 2017.01.05
Electrostatic discharge / TR3 Instrument Manufacturer Model No. Serial No. Cali. Due DateESD Simulator EM TEST Dito V0616101367 2017.04.07 Barometer Fengyun DYM3 506048 2017.10.12 Temperature/Humidity Meter zhicheng ZC1-2 TR3-TH 2017.01.05
Radio-frequency electromagnetic field / AC4 Instrument Manufacturer Model No. Serial No. Cali. Due DateSignal Generator R&S SML03 102324 2017.10.29 Power Meter Boonton 4231A 144502 2017.09.04 Power Sensor Boonton 51011-EMC 33859 2017.09.04 Power Meter Agilent E4416A GB41293844 2017.09.04 Power Sensor Agilent E9304A MY41497198 2017.09.04 RF Switch MF SW1072 RFSW980005 N/A Power Amplifier Schaffner CBA9413B 43526 NA Power Amplifier Schaffner CBA9428 43516 NA Directional Coupler Schaffner CHA 9652B 121 2017.06.25 Directional Coupler A&R DC7144A 312249 2017.06.25 Electric Field Probe ETS-LINDGREN HI-6105 00114789 2017.09.25 Bilog Antenna Schaffner CBL6141A 4278 N/A Horn Antenna A&R AT4002A 312312 N/A Temperature/Humidity Meter Zhicheng ZC1-2 AC4-TH 2017.01.05
Report No.: 16C2012E-RF-CE-P01V01
Page: 15 of 96
Fast transients common mode / TR2 Instrument Manufacturer Model No. Serial No. Cali. Due DateImmunity Test System Teseq GmbH NSG 3060 1824 2017.12.11 Automatic Step transformer Teseq GmbH VAR 3005-S16 900 2017.12.11 CDN Teseq GmbH CDN 3061 1568 2017.12.11 CDN Teseq GmbH CDN 3063 1997 2017.04.09 CDN Teseq GmbH CDN 3425 2029 2017.12.11 Temperature/Humidity Meter zhicheng ZC1-2 TR2-TH 2017.01.05
Surges / TR2 Instrument Manufacturer Model No. Serial No. Cali. Due DateImmunity Test System Teseq GmbH NSG 3060 1824 2017.12.11 Automatic Step transformer Teseq GmbH VAR 3005-S16 900 2017.12.11 CDN Teseq GmbH CDN 3061 1568 2017.12.11 CDN Teseq GmbH CDN 3063 1997 2017.04.09 CDN Teseq GmbH CDN 118 40652 2017.12.11 CDN Teseq GmbH CDN 118 40644 2017.12.11 Signal Line Coupling Network
Teseq GmbH INA183 41467 2017.12.15
Signal Line Coupling Network
Teseq GmbH IAN175 40407 2017.12.15
Signal Line Coupling Network
Teseq GmbH INA181 41494 2017.12.15
Signal Line Coupling Network
Teseq GmbH INA181 41499 2017.12.15
Signal Line Coupling Network
Teseq GmbH INA185 41954 2017.12.15
Signal Line Coupling Network
Teseq GmbH INA185 41477 2017.12.15
Signal Line Coupling Network
Teseq GmbH CDN 117 31806 2017.03.05
Temperature/Humidity Meter zhicheng ZC1-2 TR2-TH 2017.01.05 Radio frequency common mode / TR2 Instrument Manufacturer Model No. Serial No. Cali. Due DateRF-Generator Schaffner NSG2070 1120 2016.12.31 Attenuator Schaffner INA2070-1 2120 2017.10.28 Coupling / Decoupling Network
Schaffner CDN M016 21249 2017.10.16
Coupling / Decoupling Network
Teseq GmbH CDN M016 24484 2017.10.16
Coupling / Decoupling Network
Schaffner CDN T400 19083 2017.10.16
Coupling / Decoupling Network
Teseq GmbH CDN T400 22461 2017.10.16
Coupling / Decoupling Network
Teseq GmbH CDN T800 26167 2017.02.04
Coupling / Decoupling Network
Teseq GmbH CDN M525 31021 2017.03.05
EM Clamp Schaffner KEMZ 801 21041 2017.10.16 Temperature/Humidity Meter zhicheng ZC1-2 TR2-TH 2017.01.05
Report No.: 16C2012E-RF-CE-P01V01
Page: 16 of 96
Voltage dips and interruptions / TR2 Instrument Manufacturer Model No. Serial No. Cali. Due DateImmunity Test System Teseq GmbH NSG 3060 1824 2017.12.11 Automatic Steptransformer Teseq GmbH VAR 3005-S16 900 2017.12.11 CDN Teseq GmbH CDN 3061 1568 2017.12.11 Temperature/Humidity Meter zhicheng ZC1-2 TR2-TH 2017.01.05
Transients and Surges / TR11 Instrument Manufacturer Type No. Serial No Cali. Due DateMicro Transient Generator TESEQ MT 5511 1475 2017.06.25 Load Dump Generator TESEQ LD 5550 2136 2017.06.25 Fast Transient Generator TESEQ FT 5531 2056 2017.06.25 Power Amplifier TESEQ PA 5840-75/230 4150 2017.06.25 Function Generator TESEQ FG 5621 1322 2017.06.25 DC Switch TESEQ DS 5630 1318 2017.06.25 Power Amplifier TESEQ PA 5640 1262 2017.06.25 Transformer Conducted Coupler
TESEQ TC 5650 1243 2017.06.25
Automotive emission system
TESEQ AES 5501 1312 2017.03.05
Power Amplifier TESEQ PA 5740 1198 2017.06.25 Temperature/Humidity Meter BOYANG HTC-8 TR11 2017.07.15
Report No.: 16C2012E-RF-CE-P01V01
Page: 17 of 96
2.3. Measurement Uncertainty Conducted emission at mains terminals and telecommunication ports / TR1
The maximum measurement uncertainty is evaluated as:
Mains: 9kHz~150kHz: 2.80dB
150kHz~30MHz:2.40dB
Telecommunication ports:
ISN T800: 150kHz~30MHz: 3.60 dB
ISN T8-Cat6: 150kHz~30MHz: 3.50 dB
ISN ST08: 150kHz~30MHz: 3.10 dB
Radiated emission / AC1
The maximum measurement uncertainty is evaluated as:
Horizontal: 30MHz~300MHz: 3.50 dB
300MHz~1GHz: 3.20 dB
1GHz~18GHz: 4.80 dB
Vertical: 30MHz~300MHz: 3.60 dB
300MHz~1GHz: 3.10 dB
1GHz~18GHz: 4.50 dB
Radiated emission / AC2
The maximum measurement uncertainty is evaluated as:
Horizontal: 30MHz~300MHz: 3.60 dB
300MHz~1GHz: 3.10 dB
Vertical: 30MHz~300MHz: 3.20 dB
300MHz~1GHz: 3.20 dB
Radiated emission / AC3
The maximum measurement uncertainty is evaluated as:
Horizontal: 30MHz~300MHz: 3.50 dB
300MHz~1GHz: 3.60 dB
Vertical: 30MHz~300MHz: 3.60 dB
300MHz~1GHz: 3.50 dB
Radiated emission / AC5
The maximum measurement uncertainty is evaluated as:
Horizontal: 30MHz~300MHz: 3.90 dB
300MHz~1GHz: 3.60 dB
1GHz~18GHz: 5.00 dB
Vertical: 30MHz~300MHz: 3.80 dB
300MHz~1GHz: 3.50 dB
1GHz~18GHz: 4.80 dB
Harmonic current emissions / TR1
Report No.: 16C2012E-RF-CE-P01V01
Page: 18 of 96
The maximum measurement uncertainty is evaluated as: 1.8 dB.
Voltage fluctuation and flicker / TR1
The maximum measurement uncertainty is evaluated as: 1.5 dB.
Electrostatic discharge / TR3
The maximum measurement uncertainty is evaluated as Rise Time: 6.4 %,
Peak Current: 6 %, Current at 30 ns: 6 %, Current at 60 ns: 6 %.
Radio frequency electromagnetic field / AC4
The maximum measurement uncertainty is evaluated as 1.48dB.
Fast transients common mode / TR2
The maximum measurement uncertainty is evaluated as Voltage: 4%, Time: 2%.
Surges / TR2
The maximum measurement uncertainty is evaluated as Voltage: 4%, Time: 2%.
Radio frequency common mode / TR2
The maximum measurement uncertainty is evaluated as CDN: 1.52dB, EM Clamp: 1.92dB.
Voltage dips and interruptions / TR2
The maximum measurement uncertainty is evaluated as Voltage: 4%, Time: 2%.
Transients and surges / TR11
The maximum measurement uncertainty is evaluated as Voltage: 1.60%, Time: 2.60%.
Report No.: 16C2012E-RF-CE-P01V01
Page: 19 of 96
2.4. Performance Criteria
The performance criteria criteria are used to take a decision on whether a radio equipment passes or
fails immunity tests.
For the purpose of the present document four categories of performance criteria apply:
performance criteria for continuous phenomena applied to transmitters;
performance criteria for transient phenomena applied to transmitters;
performance criteria for continuous phenomena applied to receivers;
performance criteria for transient phenomena applied to receivers.
Normally, the performance criteria depend on the type of radio equipment. Thus, the present
document only contains general performance criteria commonly used for the assessment of radio
equipment. More specific and product-related performance criteria for a dedicated type of radio
equipment may be found in the part of EN 301 489 series [11] dealing with the particular type of radio
equipment.
(1) Performance criteria for continuous phenomena applied to transmitters and receivers
If no further details are given in the relevant part of EN 301 489 series [11] dealing with the particular
type of radio equipment, the following general performance criteria for continuous phenomena shall
apply.
During and after the test, the apparatus shall continue to operate as intended. No degradation of
performance or loss of function is allowed a permissible performance level specified by the
manufacturer when the apparatus is used as intended. In some cases this permissible performance
level may be replaced by a permissible loss of performance.
During the test the EUT shall not unintentionally transmit or change its actual operating state and
stored data.
If the minimum performance level or the permissible performance loss is not specified by the
manufacturer, then either of these may be deduced from the product description and documentation
and what the user may reasonably expect from the apparatus if used as intended.
(2) Performance criteria for transient phenomena applied to transmitters and receivers
If no further details are given in the relevant part of EN 301 489 series [11] dealing with the particular
type of radio equipment, the following general performance criteria for transient phenomena shall
apply.
After the test, the apparatus shall continue to operate as intended. No degradation of performance or
loss of function is allowed below a permissible performance level specified by the manufacturer,
when the apparatus is used as intended. In some cases this permissible performance level may be
replaced by a permissible loss of performance.
During the EMC exposure to an electromagnetic phenomenon, a degradation of performance is,
however, allowed. No change of the actual mode of operation (e.g. unintended transmission) or
Report No.: 16C2012E-RF-CE-P01V01
Page: 20 of 96
stored data is allowed.
If the minimum performance level or the permissible performance loss is not specified by the
manufacturer, then either of these may be deduced from the product description and documentation
and what the user may reasonably expect from the apparatus if used as intended.
(3) Performance criteria for equipment which does not provide a continuous communication
link
For radio equipment which does not provide a continuous communication link, the performance
criteria described in clauses (1) and (2) are not appropriate, then the manufacturer shall declare, for
inclusion in the test report, his own specification for an acceptable level of performance or
degradation of performance during and/or after the immunity tests. The performance specification
shall be included in the product description and documentation. The related specifications set out in
clause 5.3 of EN 301 489-1 V1.9.2 (2011-09) have also to be taken into account.
The performance criteria specified by the manufacturer shall give the same degree of immunity
protection as called for in clauses (1) and (2).
(4) Performance criteria for ancillary equipment tested on a stand alone basis
If ancillary equipment is intended to be tested on a stand alone basis, the performance criteria
described in clauses (1) and (2) are not appropriate, then the manufacturer shall declare, for
inclusion in the test report, his own specification for an acceptable level of performance or
degradation of performance during and/or after the immunity tests. The performance specification
shall be included in the product description and documentation. The related specifications set out in
clause 5.3 of EN 301 489-1 V1.9.2 (2011-09) have also to be taken into account.
The performance criteria specified by the manufacturer shall give the same degree of immunity
protection as called for in clauses (1) and (2).
Report No.: 16C2012E-RF-CE-P01V01
Page: 21 of 96
General performance criteria
The performance criteria are:
performance criteria A for immunity tests with phenomena of a continuous nature;
performance criteria B for immunity tests with phenomena of a transient nature;
performance criteria C for immunity tests with power interruptions exceeding a certain time.
The equipment shall meet the minimum performance criteria as specified in the following clauses.
Performance criteria for Continuous phenomena applied toTransmitters (CT)
The performance criteria A shall apply.
Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that unintentional
transmission does not occur. In systems using acknowledgement signals, it is recognized that an
ACKnowledgement (ACK) or Not ACKnowledgement (NACK) transmission may occur, and steps
should be taken to ensure that any transmission resulting from the application of the test is correctly
interpreted.
Performance criteria for Transient phenomena applied to Transmitters (TT)
The performance criteria B shall apply, except for voltage dips of 100 ms and voltage interruptions of
5 000 ms duration, for which performance criteria C shall apply.
Tests shall be repeated with the EUT in standby mode (if applicable) to ensure that unintentional
transmission does not occur. In systems using acknowledgement signals, it is recognized that an
acknowledgement (ACK) or not-acknowledgement (NACK) transmission may occur, and steps
should be taken to ensure that any transmission resulting from the application of the test is correctly
interpreted.
Performance criteria for Continuous phenomena applied to Receivers (CR)
The performance criteria A shall apply.
Where the EUT is a transceiver, under no circumstances, shall the transmitter operate
unintentionally during the test. In systems using acknowledgement signals, it is recognized that an
ACK or NACK transmission may occur, and steps should be taken to ensure that any transmission
resulting from the application of the test is correctly interpreted.
Performance criteria for Transient phenomena applied to Receivers (TR)
The performance criteria B shall apply, except for voltage dips of 100 ms and voltage interruptions of
5 000 ms duration for which performance criteria C shall apply.
Where the EUT is a transceiver, under no circumstances, shall the transmitter operate
unintentionally during the test. In systems using acknowledgement signals, it is recognized that an
ACK or NACK transmission may occur, and steps should be taken to ensure that any transmission
resulting from the application of the test is correctly interpreted.
Report No.: 16C2012E-RF-CE-P01V01
Page: 22 of 96
Performance criteria
Criteria During Test After test
A Shall operate as intended
May show degradation of performance
(see note 1)
Shall be no loss of function
Shall be no unintentional transmissions
Shall operate as intended
Shall be no degradation of performance
(see note 2)
Shall be no loss of function
Shall be no loss of stored data or user
programmable functions
B May show loss of function (one or more)
May show degradation of performance
(see note 1)
No unintentional transmission
Functions shall be self-recoverable
Shall operate as intended after recovering
Shall be no degradation of performance
(see note 2)
Shall be no loss of stored data or user
programmable functions
C May be loss of function (one or more)
Functions shall be recoverable by the
operator
Shall operate as intended after recovering
Shall be no degradation of performance
(see note 2)
NOTE 1: Degradation of performance during the test is understood as degradation to a level not below
a minimum performance level specified by the manufacturer for the use of the apparatus as
intended. In some cases the specified minimum performance level may be replaced by a
permissible degradation of performance.
If the minimum performance level or the permissible performance degradation is not
specified by the manufacturer then either of these may be derived from the product
description and documentation (including leaflets and advertising) and what the user may
reasonably expect from the apparatus if used as intended.
NOTE 2: No degradation of performance after the test is understood as no degradation below a
minimum performance level specified by the manufacturer for the use of the apparatus as
intended. In some cases the specified minimum performance level may be replaced by a
permissible degradation of performance. After the test no change of actual operating data or
user retrievable data is allowed. If the minimum performance level or the permissible
performance degradation is not specified by the manufacturer then either of these may be
derived from the product description and documentation (including leaflets and advertising)
and what the user may reasonably expect from the apparatus if used as intended.
Report No.: 16C2012E-RF-CE-P01V01
Page: 23 of 96
3. Conducted emission
3.1. Test Specification
According to EMC Standard: EN 55022
3.2. Test Setup
3.3. Limit
Limits of conducted emission for AC mains power input/output ports
Frequency range MHz
Limits dB(μV)
Quasi-peak Average
0.15 to 0.50 66 to 56 56 to 46
0.50 to 5 56 46
5 to 30 60 50
NOTE 1: The lower limit shall apply at the transition frequencies. NOTE 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz.
Report No.: 16C2012E-RF-CE-P01V01
Page: 24 of 96
Limits of conducted emission for DC power input/output ports
Frequency range MHz
Limits dB(μV)
Quasi-peak Average
0.15 to 0.50 66 to 56 56 to 46
0.50 to 5 56 46
5 to 30 60 50
NOTE 1: The lower limit shall apply at the transition frequencies. NOTE 2: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz.
Equipment intended to be used in telecommunication centres only
Frequency range MHz
Limits dB(μV)
Quasi-peak Average
0.15 to 0.50 79 66
0.50 to 30 73 60
NOTE: The lower limit shall apply at the transition frequency.
Limits of conducted emission for DC power input/output ports
Limits of conducted emission for telecommunication ports
Frequency range MHz
Voltage Limits dB(μV)
Current limits dB(μA)
Quasi-peak Average Quasi-peak Average
0.15 to 0.50 84 to 74 74 to 64 40 to 30 30 to 20
0.50 to 30 74 64 30 20
NOTE 1: The limits decrease linearly with the logarithm of the frequency in the range 0.15MHz to 0.5MHz. NOTE 2: The current and voltage disturbance limits are derived for use with an impedance stabilization network (ISN) which presents a common mode (asymmetric mode) impedance of 150Ω to the telecommunication port under test (conversion factor is 20 log10150 / I = 44dB).
Equipment intended to be used in telecommunication centres only
Frequency range MHz
Voltage Limits dB(μV)
Current limits dB(μA)
Quasi-peak Average Quasi-peak Average
Report No.: 16C2012E-RF-CE-P01V01
Page: 25 of 96
0.15 to 0.50 97 to 87 84 to 74 53 to 43 40 to 30
0.50 to 30 87 74 43 30
NOTE 1: The limits decrease linearly with the logarithm of the frequency in the range 0.15MHz to 0.5MHz. NOTE 2: The current and voltage disturbance limits are derived for use with an impedance stabilization network (ISN) which presents a common mode (asymmetric mode) impedance of 150Ω to the telecommunication port under test (conversion factor is 20 log10150 / I = 44dB).
3.4. Test Procedure
For AC mains power input/output ports:
The EUT and simulators are connected to the main power through a line impedance
stabilization network (L.I.S.N.). This provides a 50Ω / 50μH or 50Ω / 50μH + 5Ω coupling
impedance for the measuring equipment. The peripheral devices are also connected to the
main power through a LISN that provides a 50Ω / 50μH or 50Ω / 50μH + 5Ω coupling
impedance with 50Ω termination.
Both sides of A.C. line are checked for maximum conducted interference.
Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a
receiver bandwidth of 9kHz.
For DC power input/output ports:
The EUT and simulators are connected to the main power through a Artificial Mains Networks
(AMN).
For radio and ancillary equipment for fixed use, the Artificial Mains Networks (AMN) as
specified in EN 55022 [1] shall be used and be connected to a DC power source.
For mobile radio and ancillary equipment intended to be connected to the vehicles’s onboard
DC mains, an Artificial Network (AN) as specified in CISPR 25 [10] shall be used and be
connected to a DC power source.
Both sides of lines are checked for maximum conducted interference.
Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a
receiver bandwidth of 9kHz.
For telecommunication ports:
The mains voltage shall be supplied to the EUT via the LISN when the measurement of
telecommunication port is performed. The common mode disturbances at the
telecommunication port shall be connected to the ISN, which is 150Ω impedance.
Both alternative cables are tested related to the LCL requested.
Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a
receiver bandwidth of 9kHz.
Report No.: 16C2012E-RF-CE-P01V01
Page: 26 of 96
3.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 27 of 96
3.6. Test Result
Engineer: Bob
Site: TR1 Time: 2016/12/12
Limit: EN55022_CE_Mains_ClassB Margin: 0
Probe: ENV216_101044(0.009-30MHz) Polarity: Line
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure Level
(dBuV)
Reading Level
(dBuV)
Over Limit
(dB)
Limit
(dBuV)
Probe
(dB)
Cable
(dB)
Amp
(dB)
Type
1 * 0.470 29.375 19.743 -27.139 56.514 9.590 0.043 0.000 QP
2 0.470 16.309 6.676 -30.205 46.514 9.590 0.043 0.000 AV
3 0.682 25.964 16.326 -30.036 56.000 9.590 0.049 0.000 QP
4 0.682 11.087 1.449 -34.913 46.000 9.590 0.049 0.000 AV
5 1.250 26.465 16.797 -29.535 56.000 9.602 0.065 0.000 QP
6 1.250 11.743 2.075 -34.257 46.000 9.602 0.065 0.000 AV
7 2.234 25.388 15.683 -30.612 56.000 9.611 0.094 0.000 QP
8 2.234 10.903 1.198 -35.097 46.000 9.611 0.094 0.000 AV
9 3.146 24.964 15.236 -31.036 56.000 9.614 0.114 0.000 QP
10 3.146 11.019 1.291 -34.981 46.000 9.614 0.114 0.000 AV
11 4.094 24.457 14.707 -31.543 56.000 9.617 0.133 0.000 QP
12 4.094 10.606 0.856 -35.394 46.000 9.617 0.133 0.000 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 28 of 96
Engineer: Bob
Site: TR1 Time: 2016/12/12
Limit: EN55022_CE_Mains_ClassB Margin: 0
Probe: ENV216_101044(0.009-30MHz) Polarity: Neutral
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure Level
(dBuV)
Reading Level
(dBuV)
Over Limit
(dB)
Limit
(dBuV)
Probe
(dB)
Cable
(dB)
Amp
(dB)
Type
1 0.182 27.679 18.080 -36.715 64.394 9.573 0.026 0.000 QP
2 0.182 13.051 3.452 -41.343 54.394 9.573 0.026 0.000 AV
3 0.310 27.713 18.107 -32.257 59.970 9.574 0.032 0.000 QP
4 0.310 12.837 3.231 -37.134 49.970 9.574 0.032 0.000 AV
5 * 0.490 25.244 15.621 -30.924 56.168 9.580 0.043 0.000 QP
6 0.490 11.742 2.119 -34.426 46.168 9.580 0.043 0.000 AV
7 1.314 23.647 13.997 -32.353 56.000 9.583 0.067 0.000 QP
8 1.314 11.034 1.384 -34.966 46.000 9.583 0.067 0.000 AV
9 2.342 22.267 12.575 -33.733 56.000 9.592 0.100 0.000 QP
10 2.342 9.532 -0.160 -36.468 46.000 9.592 0.100 0.000 AV
11 3.274 22.300 12.587 -33.700 56.000 9.599 0.115 0.000 QP
12 3.274 9.921 0.207 -36.079 46.000 9.599 0.115 0.000 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 29 of 96
Engineer: Bob
Site: TR1 Time: 2016/12/12
Limit: EN55022_CE_ISN(Voltage)_ClassB Margin: 0
Probe: TESEQ-ISN-T800_30306(0.15-30MHz) Polarity:
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data LAN-10Mbps
No Mark Frequency
(MHz)
Measure Level
(dBuV)
Reading Level
(dBuV)
Over Limit
(dB)
Limit
(dBuV)
Probe
(dB)
Cable
(dB)
Amp
(dB)
Type
1 0.410 64.924 54.940 -10.725 75.648 9.944 0.039 0.000 QP
2 0.410 55.346 45.363 -10.302 65.648 9.944 0.039 0.000 AV
3 0.450 66.558 56.594 -8.317 74.875 9.920 0.044 0.000 QP
4 * 0.450 57.088 47.124 -7.788 64.875 9.920 0.044 0.000 AV
5 0.510 64.874 54.942 -9.126 74.000 9.888 0.044 0.000 QP
6 0.510 54.475 44.544 -9.525 64.000 9.888 0.044 0.000 AV
7 0.550 65.245 55.321 -8.755 74.000 9.877 0.048 0.000 QP
8 0.550 53.147 43.222 -10.853 64.000 9.877 0.048 0.000 AV
9 0.626 60.753 50.850 -13.247 74.000 9.858 0.044 0.000 QP
10 0.626 50.452 40.549 -13.548 64.000 9.858 0.044 0.000 AV
11 1.286 59.514 49.680 -14.486 74.000 9.770 0.064 0.000 QP
12 1.286 48.875 39.041 -15.125 64.000 9.770 0.064 0.000 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 30 of 96
Engineer: Bob
Site: TR1 Time: 2016/12/12
Limit: EN55022_CE_ISN(Voltage)_ClassB Margin: 0
Probe: TESEQ-ISN-T800_30306(0.15-30MHz) Polarity:
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data LAN-100Mbps
No Mark Frequency
(MHz)
Measure Level
(dBuV)
Reading Level
(dBuV)
Over Limit
(dB)
Limit
(dBuV)
Probe
(dB)
Cable
(dB)
Amp
(dB)
Type
1 0.450 68.328 58.364 -6.547 74.875 9.920 0.044 0.000 QP
2 * 0.450 59.947 49.983 -4.928 64.875 9.920 0.044 0.000 AV
3 0.498 65.302 55.365 -8.732 74.033 9.893 0.043 0.000 QP
4 0.498 57.485 47.548 -6.548 64.033 9.893 0.043 0.000 AV
5 0.554 64.915 54.992 -9.085 74.000 9.876 0.047 0.000 QP
6 0.554 54.271 44.348 -9.729 64.000 9.876 0.047 0.000 AV
7 0.574 64.478 54.561 -9.522 74.000 9.872 0.045 0.000 QP
8 0.574 54.929 45.013 -9.071 64.000 9.872 0.045 0.000 AV
9 0.646 63.335 53.435 -10.665 74.000 9.854 0.046 0.000 QP
10 0.646 51.586 41.686 -12.414 64.000 9.854 0.046 0.000 AV
11 1.254 58.196 48.359 -15.804 74.000 9.772 0.064 0.000 QP
12 1.254 49.114 39.278 -14.886 64.000 9.772 0.064 0.000 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 31 of 96
3.7. Test Photograph Test Mode: Mode 1: Transmission Data
Description: Front View of Conducted emission Test Setup (AC mains power input ports)
Test Mode: Mode 1: Transmission Data
Description: Side View of Conducted emission Test Setup (AC mains power input ports)
Report No.: 16C2012E-RF-CE-P01V01
Page: 32 of 96
Test Mode: Mode 1: Transmission Data
Description: Front View of Conducted emission Test Setup (LAN)
Test Mode: Mode 1: Transmission Data
Description: Side View of Conducted emission Test Setup (LAN)
Report No.: 16C2012E-RF-CE-P01V01
Page: 33 of 96
4. Radiated emission
4.1. Test Specification
According to EMC Standard: EN 55022
4.2. Test Setup
Below 1GHz Test Setup
Above 1GHz Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 34 of 96
4.3. Limit
Limits below 1GHz
Limits for radiated emission at a measuring distance of 10m
Frequency range MHz
Quasi-peak limits dB(μV/m)
30 to 230 30
230 to 1000 37
NOTE 1: The lower limit shall apply at the transition frequency. NOTE 2: Additional provisions may be required for cases where interference occurs.
Limits above 1GHz
Limits for radiated emission at a measuring distance of 3m
Frequency range GHz
Average limit dB(μV/m)
Peak-peak dB(μV/m)
1 to 3 50 70
3 to 6 54 74
NOTE: The lower limit applies at transition frequency.
Ancillary equipment intended to be used in telecommunication centres only
Frequency range GHz
Average limit dB(μV/m)
Peak-peak dB(μV/m)
1 to 3 56 76
3 to 6 60 80
NOTE: The lower limit applies at transition frequency.
Report No.: 16C2012E-RF-CE-P01V01
Page: 35 of 96
4.4. Test Procedure
The EUT and its simulators are placed on a turntable which is 0.8 meter above ground. The
turntable can rotate 360 degrees to determine the position of the maximum emission level. The
EUT was positioned such that the distance from antenna to the EUT was 10 meters for below
1GHz and 3 meters for above 1GHz.
The antenna can move up and down between 1 meter and 4 meters to find out the maximum
emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order to
find the maximum emission, all of the interface cables must be changed during radiated
measurement.
The bandwidth below 1GHz setting on the receiver is 120kHz and above 1GHz is 1MHz.
Conditional testing procedure:
The highest internal source of an EUT is defined as the highest frequency generated or used
within the EUT or on which the EUT operates or tunes.
If the highest frequency of the internal sources of the EUT is less than 108 MHz, the
measurement shall only be made up to 1 GHz.
If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz,
the measurement shall only be made up to 2 GHz.
If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the
measurement shall only be made up to 5 GHz.
If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement
shall be made up to 5 times the highest frequency or 6 GHz, whichever is less.
The radiated field measurement method above 1 GHz is based on measurement of the
maximum electric field emitted from the EUT as shown below
Report No.: 16C2012E-RF-CE-P01V01
Page: 36 of 96
Definitions referring to Figure
Validated test volume: The volume validated during the site validation procedure (see8.3.3of
ClSPR 16-1-4:2010). Typically, this is the largest diameter EUT that can
be used in the test facility.
EUT: The smallest diameter cylinder that will fully encompass all portions of the actual
EUT, including cable racks and a minimum length of 30 cm of cables. The EUT that
is located within this cylinder must be capable of rotating about its centre (typically
by aremotely controlled turntable). The EUT must be located within the validated
test volume. A maximum of 30 cm of ω (see definition of ω below) may be below the
height of absorbers on the floor only when the EUT is floor standing and cannot be
raised above the height of the absorbers.
θ3 dB: The minimum 3 dB beamwidth of the receive antenna at each frequency of interest.
θ3 dB is the minimum of both the E-plane and H-plane values at each frequency. θ
3dB may be obtained from manufacturer provided data for the receive antenna.
d: The measurement distance (in meters). This is measured as the horizontal distance
between the periphery of the EUT and the reference point of the receive antenna.
ω: The dimension of the line tangent to the EUT formed by θ3 dB at the
measurement distance d. Equation (10) shall be used to calculate ω for each actual
antenna and measurement distance used. The values of ω shall be included in the
test report. This calculation may be based on the manufacturer-provided
receive-antenna beamwidth specifications :
ω = 2 × d × tan (0,5 × θ3 dB)
Report No.: 16C2012E-RF-CE-P01V01
Page: 37 of 96
DRG Horn Antenna(M/N:3117)test dimension of ω
Frequency GHz θ3 dB (min) ° ω m
1 90 6.00
2 60 3.46
3 75 4.60
4 60 3.46
5 60 3.46
6 50 2.80
7 45 2.49
8 40 2.18
9 35 1.89
10 30 1.61
11 35 1.89
12 40 2.18
13 35 1.89
14 35 1.89
15 35 1.89
16 35 1.89
17 30 1.61
18 20 1.06
Note:The antenna’s moving up and down is determined by ω value for above 1GHz, to ensure
that the acceptable range of the testing antenna can cover the whole range of EUT.
4.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 38 of 96
4.6. Test Result
Engineer: Glory
Site: AC1 Time: 2016/12/15
Limit: EN55022_RE(10m)_ClassB Margin: 0
Probe: CBL6112B_2931(30-1000MHz) Polarity: Horizontal
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure
Level
(dBuV/m)
Reading
Level
(dBuV)
Over
Limit
(dB)
Limit
(dBuV/m)
Probe
(dB/m)
Cable
(dB)
Amp
(dB)
Ant
Pos
(cm)
Table
Pos
(deg)
Type
1 * 34.065 16.834 22.300 -13.166 30.000 15.773 1.029 22.268 100 156 QP
2 42.465 13.429 23.200 -16.571 30.000 11.363 1.158 22.291 100 114 QP
3 116.933 10.613 20.600 -19.387 30.000 10.275 2.022 22.284 200 256 QP
4 199.524 11.828 22.300 -18.172 30.000 9.039 2.735 22.247 200 300 QP
5 896.265 22.699 16.200 -14.301 37.000 20.697 6.711 20.910 200 331 QP
6 989.324 23.193 15.600 -13.807 37.000 21.365 7.135 20.907 100 140 QP
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 39 of 96
Engineer: Glory
Site: AC1 Time: 2016/12/15
Limit: EN55022_RE(10m)_ClassB Margin: 0
Probe: CBL6112B_2933(30-1000MHz) Polarity: Vertical
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure
Level
(dBuV/m)
Reading
Level
(dBuV)
Over
Limit
(dB)
Limit
(dBuV/m)
Probe
(dB/m)
Cable
(dB)
Amp
(dB)
Ant
Pos
(cm)
Table
Pos
(deg)
Type
1 33.354 16.329 22.300 -13.671 30.000 16.238 1.138 23.347 100 156 QP
2 44.165 16.709 28.300 -13.291 30.000 10.466 1.324 23.381 200 223 QP
3 91.165 12.714 25.300 -17.286 30.000 8.868 1.968 23.422 100 225 QP
4 603.265 20.956 19.200 -16.044 37.000 18.777 5.826 22.847 100 45 QP
5 885.265 24.042 18.600 -12.958 37.000 20.619 7.375 22.552 200 263 QP
6 * 994.534 25.126 18.200 -11.874 37.000 21.439 7.933 22.446 100 156 QP
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 40 of 96
Engineer: Steven
Site: AC5 Time: 2016/12/20
Limit: EN55022_RE(3m)_ClassB Margin: 0
Probe: Horn_3117_00167055(1-18GHz) Polarity: Horizontal
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure
Level
(dBuV/m)
Reading
Level
(dBuV)
Over
Limit
(dB)
Limit
(dBuV/m)
Probe
(dB/m)
Cable
(dB)
Amp
(dB)
Ant
Pos
(cm)
Table
Pos
(deg)
Type
1 2372.500 47.588 58.764 -22.412 70.000 32.147 4.148 47.470 200 23 PK
2 2372.654 28.090 39.264 -21.910 50.000 32.147 4.149 47.470 200 23 AV
3 * 2512.500 48.245 59.279 -21.755 70.000 32.312 4.125 47.471 100 0 PK
4 2512.624 26.119 37.154 -23.881 50.000 32.313 4.123 47.471 100 0 AV
5 4740.000 42.633 50.276 -31.367 74.000 33.948 6.216 47.807 200 23 PK
6 4740.654 23.621 31.264 -30.379 54.000 33.948 6.216 47.807 200 23 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 41 of 96
Engineer: Steven
Site: AC5 Time: 2016/12/22
Limit: EN55022_RE(3m)_ClassB Margin: 0
Probe: Horn_3117_00167055(1-18GHz) Polarity: Vertical
EUT: 300Mbps Wi-Fi Range Extender Power: AC 230V/50Hz
Note: Mode 1: Transmission Data
No Mark Frequency
(MHz)
Measure
Level
(dBuV/m)
Reading
Level
(dBuV)
Over
Limit
(dB)
Limit
(dBuV/m)
Probe
(dB/m)
Cable
(dB)
Amp
(dB)
Ant
Pos
(cm)
Table
Pos
(deg)
Type
1 2372.500 50.967 62.143 -19.033 70.000 32.147 4.148 47.470 100 2 PK
2 2372.654 30.951 42.125 -19.049 50.000 32.147 4.149 47.470 100 2 AV
3 2525.000 50.308 61.106 -19.692 70.000 32.325 4.340 47.463 200 214 PK
4 2525.265 29.473 40.265 -20.527 50.000 32.325 4.345 47.463 200 214 AV
5 2567.500 50.585 61.306 -19.415 70.000 32.367 4.329 47.417 100 145 PK
6 * 2567.654 31.642 42.364 -18.358 50.000 32.368 4.329 47.419 100 145 AV
Note:
1. " * ", means this data is the worst emission level.
2. Measurement Level = Reading Level + Factor(Probe+Cable-Amp).
Report No.: 16C2012E-RF-CE-P01V01
Page: 42 of 96
4.7. Test Photograph Test Mode: Mode 1: Transmission Data
Description: Front View of Radiated emission Test Setup (Below 1GHz)
Test Mode: Mode 1: Transmission Data
Description: Rear View of Radiated emission Test Setup (Below 1GHz)
Report No.: 16C2012E-RF-CE-P01V01
Page: 43 of 96
Test Mode: Mode 1: Transmission Data
Description: Front View of Radiated emission Test Setup (Above 1GHz)
Test Mode: Mode 1: Transmission Data
Description: Rear View of Radiated emission Test Setup (Above 1GHz)
Report No.: 16C2012E-RF-CE-P01V01
Page: 44 of 96
5. Harmonic current emissions
5.1. Test Specification
According to EMC Standard: EN 61000-3-2
5.2. Test Setup
5.3. Limit
(a) Limits of Class A Harmonics Currents
Harmonics
Order
n
Maximum Permissible
harmonic current
A
Harmonics
Order
n
Maximum Permissible
harmonic current
A
Odd harmonics Even harmonics
3 2.30 2 1.08
5 1.14 4 0.43
7 0.77 6 0.30
9 0.40 8 n 40 0.23 * 8/n
11 0.33
13 0.21
15 n 39 0.15 * 15/n
Report No.: 16C2012E-RF-CE-P01V01
Page: 45 of 96
(b) Limits of Class B Harmonics Currents
For Class B equipment, the harmonic of the input current shall not exceed the maximum
permissible values given in table that is the limit of Class A multiplied by a factor of 1.5.
(c) Limits of Class C Harmonics Currents
Harmonics Order
n
Maximum Permissible harmonic current
Expressed as a percentage of the input
current at the fundamental frequency
%
2 2
3 30.λ*
5 10
7 7
9 5
11 n 39
(odd harmonics only) 3
*λ is the circuit power factor
(d) Limits of Class D Harmonics Currents
Harmonics Order
n
Maximum Permissible
harmonic current per watt
mA/W
Maximum Permissible
harmonic current
A
3 3.4 2.30
5 1.9 1.14
7 1.0 0.77
9 0.5 0.40
11 0.35 0.33
11 n 39
(odd harmonics only) 3.85/n See limit of Class A
Report No.: 16C2012E-RF-CE-P01V01
Page: 46 of 96
5.4. Test Procedure
The EUT is supplied in series with power analyzer from a power source having the same
normal voltage and frequency as the rated supply voltage and the equipment under test. And
the rated voltage at the supply voltage of EUT of 0.98 times and 1.02 times shall be performed.
5.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 47 of 96
5.6. Test Result Test Site TR1 Date of Test 2016.12.12
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 25C Humidity 48%RH
Barometric Pressure 101kPa Test Engineer Bob
Test Mode Mode 1: Transmission Data
Test Result: N/L Source qualification: Normal
Current & voltage waveforms
-0.8
-0.4
0.0
0.4
0.8
-300
-200
-100
0
100
200
300
Cu
rre
nt (A
mp
s) V
olta
ge
(Vo
lts)
Harmonics and Class A limit line European Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Curr
ent R
MS
(Am
ps)
Harmonic #4 8 12 16 20 24 28 32 36 40
Test result: N/L
Report No.: 16C2012E-RF-CE-P01V01
Page: 48 of 96
Test Result: N/L Source qualification: Normal THC(A): 0.014 I-THD(%): 214.8 POHC(A): 0.000 POHC Limit(A): 0.251 Highest parameter values during test:
V_RMS (Volts): 228.98 Frequency(Hz): 50.00 I_Peak (Amps): 0.932 I_RMS (Amps): 0.021 I_Fund (Amps): 0.007 Crest Factor: 43.541 Power (Watts): 1.7 Power Factor: 0.429
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.001 1.080 N/A 0.001 1.620 N/A N/L 3 0.006 2.300 0.2 0.007 3.450 0.2 N/L 4 0.001 0.430 N/A 0.001 0.645 N/A N/L 5 0.005 1.140 0.5 0.006 1.710 0.4 N/L 6 0.000 0.300 N/A 0.000 0.450 N/A N/L 7 0.005 0.770 0.7 0.006 1.155 0.5 N/L 8 0.000 0.230 N/A 0.000 0.345 N/A N/L 9 0.005 0.400 N/A 0.006 0.600 N/A N/L 10 0.000 0.184 N/A 0.000 0.276 N/A N/L 11 0.005 0.330 N/A 0.005 0.495 N/A N/L 12 0.000 0.153 N/A 0.000 0.230 N/A N/L 13 0.004 0.210 N/A 0.005 0.315 N/A N/L 14 0.000 0.131 N/A 0.000 0.197 N/A N/L 15 0.004 0.150 N/A 0.004 0.225 N/A N/L 16 0.000 0.115 N/A 0.000 0.173 N/A N/L 17 0.003 0.132 N/A 0.004 0.198 N/A N/L 18 0.000 0.102 N/A 0.000 0.153 N/A N/L 19 0.003 0.118 N/A 0.003 0.178 N/A N/L 20 0.000 0.092 N/A 0.000 0.138 N/A N/L 21 0.002 0.107 N/A 0.003 0.161 N/A N/L 22 0.000 0.084 N/A 0.000 0.125 N/A N/L 23 0.002 0.098 N/A 0.002 0.147 N/A N/L 24 0.000 0.077 N/A 0.000 0.115 N/A N/L 25 0.001 0.090 N/A 0.002 0.135 N/A N/L 26 0.000 0.071 N/A 0.000 0.107 N/A N/L 27 0.001 0.083 N/A 0.001 0.125 N/A N/L 28 0.000 0.066 N/A 0.000 0.099 N/A N/L 29 0.001 0.078 N/A 0.001 0.116 N/A N/L 30 0.000 0.061 N/A 0.000 0.092 N/A N/L 31 0.001 0.073 N/A 0.001 0.109 N/A N/L 32 0.000 0.058 N/A 0.000 0.086 N/A N/L 33 0.000 0.068 N/A 0.000 0.102 N/A N/L 34 0.000 0.054 N/A 0.000 0.081 N/A N/L 35 0.000 0.064 N/A 0.000 0.096 N/A N/L 36 0.000 0.051 N/A 0.000 0.077 N/A N/L 37 0.000 0.061 N/A 0.000 0.091 N/A N/L 38 0.000 0.048 N/A 0.000 0.073 N/A N/L 39 0.000 0.058 N/A 0.000 0.087 N/A N/L 40 0.000 0.046 N/A 0.000 0.069 N/A N/L
1. Dynamic limits were applied for this test. The highest harmonics values in the above table may not
occur at the same window as the maximum harmonics/limit ratio.
2. According to EN61000-3-2 paragraph 7 the note 1 and 2 are valid for all applications having an active
input power >75W. Others the result should be pass.
Report No.: 16C2012E-RF-CE-P01V01
Page: 49 of 96
5.7. Test Photograph Test Mode: Mode 1: Transmission Data
Description: Harmonic current emissions Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 50 of 96
6. Voltage fluctuations and flicker
6.1. Test Specification
According to EMC Standard: EN 61000-3-3
6.2. Test Setup
6.3. Limit
The following limits apply:
- the value of Pst shall not be greater than 1.0;
- the value of Plt shall not be greater than 0.65;
- Tmax, the accumulated time value of d(t) with a deviation exceeding 3,3 % during a single
voltage change at the EUT terminals, shall not exceed 500 ms;
- the maximum relative voltage change, dmax, shall not exceed;
a) 4% without additional conditions;
b) 6% for equipment which is:
- switched manually, or
- switched automatically more frequently than twice per day, and also has either a delayed
restart (the delay being not less than a few tens of seconds), or manual restart, after a
power supply interruption.
NOTE: The cycling frequency will be further limited by the Pst and Plt limit.
For example: a dmax of 6% producing a rectangular voltage change characteristic twice per hour
will give a Plt of about 0.65.
Report No.: 16C2012E-RF-CE-P01V01
Page: 51 of 96
c) 7% for equipment which is:
- attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such
as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or
- switched on automatically, or is intended to be switched on manually, no more than twice
per day, and also has either a delayed restart (the delay being not less than a few tens of
seconds) or manual restart, after a power supply interruption.
Pst and P1t requirements shall not be applied to voltage changes caused by manual switching.
6.4. Test Procedure
The EUT is supplied in series with power analyzer from a power source having the same
normal voltage and frequency as the rated supply voltage and the equipment under test. And
the rated voltage at the supply voltage of EUT of 0.98 times and 1.02 times shall be performed.
6.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 52 of 96
6.6. Test Result Test Site TR1 Date of Test 2016.12.12
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 25C Humidity 48%RH
Barometric Pressure 101kPa Test Engineer Bob
Test Mode Mode 1: Transmission Data
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0.25
0.50
0.75
1.00
Pst
17:5
0:0
8
Plt and limit line
0.25
0.50
Plt
17:5
0:0
8
Parameter values recorded during the test: Vrms at the end of test (Volt): 228.94 Highest dt (%): 0.00 Test limit (%): N/A N/A T-max (mS): 0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): -0.05 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.206 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.090 Test limit: 0.650 Pass
Report No.: 16C2012E-RF-CE-P01V01
Page: 53 of 96
6.7. Test Photograph Test Mode: Mode 1: Transmission Data
Description: Voltage fluctuations and flicker Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 54 of 96
7. Electrostatic discharge
7.1. Test Specification
According to EMC Standard: EN 61000-4-2
7.2. Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 55 of 96
7.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
Enclosure port
Electrostatic
discharge
±4 (Contact discharge)
±8 (Air discharge)
kV (Charge voltage)
kV (Charge voltage)
B
7.4. Test Procedure
Direct application of discharges to the EUT:
Contact discharge was applied only to conductive surfaces of the EUT.
Air discharges were applied only to non-conductive surfaces of the EUT.
During the test, it was performed with single discharges. For the single discharge time
between successive single discharges will be keep longer 1 second. It was at least ten
single discharges with positive and negative at the same selected point.
The selected point, which was performed with electrostatic discharge, was marked on the
red label of the EUT.
Indirect application of discharges to the EUT:
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the
coupling plane.
The four faces of the EUT will be performed with electrostatic discharge. It was at least ten
single discharges with positive and negative at the same selected point.
7.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 56 of 96
7.6. Test Result Test Site TR3 Date of Test 2016.12.25
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Whiteside
Test Mode Mode 1: Transmission Data
Air Discharge
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV +8kV -8kV
1-9 A A A A A A Note Pass
Contact Discharge
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
10-14 A A A A Note Pass
Horizontal Coupling
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
Front A A A A Note Pass
Rear A A A A Note Pass
Left A A A A Note Pass
Right A A A A Note Pass
Vertical Coupling
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
Front A A A A Note Pass
Rear A A A A Note Pass
Left A A A A Note Pass
Right A A A A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 57 of 96
Test Site TR3 Date of Test 2016.12.25
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Whiteside
Test Mode Mode 2: Standby
Air Discharge
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV +8kV -8kV
1-9 A A A A A A Note Pass
Contact Discharge
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
10-14 A A A A Note Pass
Horizontal Coupling
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
Front A A A A Note Pass
Rear A A A A Note Pass
Left A A A A Note Pass
Right A A A A Note Pass
Vertical Coupling
Test Location Test Level
Observation Result +2kV -2kV +4kV -4kV
Front A A A A Note Pass
Rear A A A A Note Pass
Left A A A A Note Pass
Right A A A A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 58 of 96
7.7. Test Photograph Test Mode: Mode 1&2
Description: Electrostatic discharge Test Setup
Electrostatic discharge Test Location
(Mode 1&2)
Report No.: 16C2012E-RF-CE-P01V01
Page: 59 of 96
Report No.: 16C2012E-RF-CE-P01V01
Page: 60 of 96
Report No.: 16C2012E-RF-CE-P01V01
Page: 61 of 96
8. Radio frequency electromagnetic field
8.1. Test Specification
According to EMC Standard: EN 61000-4-3
8.2. Test Setup
8.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
Enclosure port
Radio frequency
electromagnetic
field
80 - 1000, 1400 - 2700
3
80
MHz
V/m (unmodulated, r.m.s)
% AM (1kHz)
A
NOTE 1: If the wanted signal is modulated at 1000Hz, then an audio signal of 400Hz shall be used. NOTE 2: The test shall be performed over the frequency range 80MHz to 1000MHz and 1400MHz to 2700MHz with the exception of the exclusion band for transmitters, receivers and duplex transceivers [see clause 4 of EN 301 489-1 V1.9.2 (2011-09)], as appropriate.
The frequencies on which the transmitter part of the EUT is intended to operate shall be
excluded from radiated emission measurements when performed in transmit mode of operation.
There shall be no frequency exclusion band applied to emission measurements of the receiver
part of transceivers or the stand alone receiver under test, and/or associated ancillary
Report No.: 16C2012E-RF-CE-P01V01
Page: 62 of 96
equipment.
The exclusion band for immunity testing shall be calculated as follows:
• lower limit of exclusion band = lowest allocated band edge frequency -5 %;
• upper limit of exclusion band = highest allocated band edge frequency +5 %.
Using the 2,450 MHz band as an example:
• lower limit of exclusion band = 2 400 - 120 = 2 280 MHz;
• upper limit of exclusion band = 2 483,5 + 124,175 = 2 607,675 MHz;
• thus the exclusion band for 2,45 GHz equipment falling within the scope of the present
document extends from 2 280 MHz to 2 607,675 MHz.
Report No.: 16C2012E-RF-CE-P01V01
Page: 63 of 96
8.4. Test Procedure
The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with
one coincident with the calibration plane such that the distance from antenna to the EUT was 3
meters.
Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on
measurement.
In order to judge the EUT performance, a CCD camera is used to monitor EUT screen.
All the scanning conditions are as follows:
Condition of Test Remarks
1. Field Strength 3V/m
2. Radiated Signal AM 80% Modulated with 1kHz
3. Scanning Frequency 80 - 1000MHz, 1400 - 2700MHz
4 Dwell Time 3 Seconds
5. Frequency Step Size f 1%
8.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 64 of 96
8.6. Test Result Test Site AC4 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Frequency
(MHz) Polarity Position
Field Strength
(V/m)
Test Result
Criterion Observation Result
80-1000 Horizontal Front 3 A Note 1 Pass
80-1000 Vertical Front 3 A Note 1 Pass
80-1000 Horizontal Rear 3 A Note 1 Pass
80-1000 Vertical Rear 3 A Note 1 Pass
80-1000 Horizontal Left 3 A Note 1 Pass
80-1000 Vertical Left 3 A Note 1 Pass
80-1000 Horizontal Right 3 A Note 1 Pass
80-1000 Vertical Right 3 A Note 1 Pass
1400-2280 Horizontal Front 3 A Note 1 Pass
1400-2280 Vertical Front 3 A Note 1 Pass
1400-2280 Horizontal Rear 3 A Note 1 Pass
1400-2280 Vertical Rear 3 A Note 1 Pass
1400-2280 Horizontal Left 3 A Note 1 Pass
1400-2280 Vertical Left 3 A Note 1 Pass
1400-2280 Horizontal Right 3 A Note 1 Pass
1400-2280 Vertical Right 3 A Note 1 Pass
2607.675-2700 Horizontal Front 3 A Note 1 Pass
2607.675-2700 Vertical Front 3 A Note 1 Pass
2607.675-2700 Horizontal Rear 3 A Note 1 Pass
2607.675-2700 Vertical Rear 3 A Note 1 Pass
2607.675-2700 Horizontal Left 3 A Note 1 Pass
2607.675-2700 Vertical Left 3 A Note 1 Pass
2607.675-2700 Horizontal Right 3 A Note 1 Pass
2607.675-2700 Vertical Right 3 A Note 1 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The exclusion band for 2,45 GHz equipment falling within the scope of the present
document extends from 2 280 MHz to 2 607.675 MHz.
Report No.: 16C2012E-RF-CE-P01V01
Page: 65 of 96
Test Site AC4 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Frequency
(MHz) Polarity Position
Field Strength
(V/m)
Test Result
Criterion Observation Result
80-1000 Horizontal Front 3 A Note 1 Pass
80-1000 Vertical Front 3 A Note 1 Pass
80-1000 Horizontal Rear 3 A Note 1 Pass
80-1000 Vertical Rear 3 A Note 1 Pass
80-1000 Horizontal Left 3 A Note 1 Pass
80-1000 Vertical Left 3 A Note 1 Pass
80-1000 Horizontal Right 3 A Note 1 Pass
80-1000 Vertical Right 3 A Note 1 Pass
1400-2280 Horizontal Front 3 A Note 1 Pass
1400-2280 Vertical Front 3 A Note 1 Pass
1400-2280 Horizontal Rear 3 A Note 1 Pass
1400-2280 Vertical Rear 3 A Note 1 Pass
1400-2280 Horizontal Left 3 A Note 1 Pass
1400-2280 Vertical Left 3 A Note 1 Pass
1400-2280 Horizontal Right 3 A Note 1 Pass
1400-2280 Vertical Right 3 A Note 1 Pass
2607.675-2700 Horizontal Front 3 A Note 1 Pass
2607.675-2700 Vertical Front 3 A Note 1 Pass
2607.675-2700 Horizontal Rear 3 A Note 1 Pass
2607.675-2700 Vertical Rear 3 A Note 1 Pass
2607.675-2700 Horizontal Left 3 A Note 1 Pass
2607.675-2700 Vertical Left 3 A Note 1 Pass
2607.675-2700 Horizontal Right 3 A Note 1 Pass
2607.675-2700 Vertical Right 3 A Note 1 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The exclusion band for 2,45 GHz equipment falling within the scope of the present
document extends from 2 280 MHz to 2 607.675 MHz.
Report No.: 16C2012E-RF-CE-P01V01
Page: 66 of 96
8.7. Test Photograph Test Mode: Mode 1&2
Description: Radio frequency electromagnetic field Test Setup
Test Mode: Mode 1&2
Description: Radio frequency electromagnetic field Test Setup (Above 1GHz)
Report No.: 16C2012E-RF-CE-P01V01
Page: 67 of 96
9. Fast transients common mode
9.1. Test Specification
According to EMC Standard: EN 61000-4-4
9.2. Test Setup
9.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
AC mains power input ports
Fast transients
common mode
±1.0
5/50
5
kV (peak)
Tr/Th ns
Repetition frequency (kHz)
B
DC power input ports (See Note)
Fast transients
common mode
±0.5
5/50
5
kV (peak)
Tr/Th ns
Repetition frequency (kHz)
B
Signal ports, telecommunication ports, and control ports (See Note)
Fast transients
common mode
±0.5
5/50
5
kV (peak)
Tr/Th ns
Repetition frequency (kHz)
B
NOTE: This test shall be additionally performed on signal ports, telecommunication ports, control ports, and DC power ports, of radio equipment and associated ancillary equipment, if the cables may be longer than 3m.
Report No.: 16C2012E-RF-CE-P01V01
Page: 68 of 96
9.4. Test Procedure
The EUT is placed on a table that is 0.8 meter height. A ground reference plane is placed on
the table, and uses a (0,1 ± 0,01)m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 0.8m*1m, and 0.65mm(copper or
aluminium of 0,25 mm minimum thickness) thick min, and projected beyond the EUT by at
least 0.1m on all sides.
For AC mains power input ports and DC power input ports:
The EUT is connected to the power mains through a coupling device that directly couples the
EFT/B interference signal.
Each of the line conductors is impressed with burst noise for 1 minute.
The length of the power lines between the coupling device and the EUT is (0,5 − 0/+0,1)m for
tabletop equipment testing.
For signal ports, telecommunication ports, and control ports:
The EFT interference signal is through a coupling clamp device couples to the signal of the
EUT with burst noise for 1 minute.
The length of the signal lines between the coupling device and the EUT is (0,5 − 0/+0,1)m for
tabletop equipment testing.
9.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 69 of 96
9.6. Test Result Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Inject
Line Polarity
Test Level
(kV)
Test Duration
(second)
Inject
Method
Test Result
CriterionObservation Result
L + 1 60 Direct A Note Pass
L - 1 60 Direct A Note Pass
N + 1 60 Direct A Note Pass
N - 1 60 Direct A Note Pass
L+N + 1 60 Direct A Note Pass
L+N - 1 60 Direct A Note Pass
LAN + 0.5 60 Clamp A Note Pass
LAN - 0.5 60 Clamp A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 70 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Inject
Line Polarity
Test Level
(kV)
Test Duration
(second)
Inject
Method
Test Result
CriterionObservation Result
L + 1 60 Direct A Note Pass
L - 1 60 Direct A Note Pass
N + 1 60 Direct A Note Pass
N - 1 60 Direct A Note Pass
L+N + 1 60 Direct A Note Pass
L+N - 1 60 Direct A Note Pass
LAN + 0.5 60 Clamp A Note Pass
LAN - 0.5 60 Clamp A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 71 of 96
9.7. Test Photograph Test Mode: Mode 1&2
Description: Fast transients common mode Test Setup (AC mains power input ports)
Test Mode: Mode 1&2
Description: Fast transients common mode Test Setup (LAN)
Report No.: 16C2012E-RF-CE-P01V01
Page: 72 of 96
10. Surges
10.1. Test Specification
According to EMC Standard: EN 61000-4-5
10.2. Test Setup
10.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
AC mains power input ports (See Note 1)
Surges 1.2/50 (8/20)
1 line to line
2 line to ground
Tr/Th us
kV (peak)
kV (peak)
B
Telecommunication ports directly connected to outdoor cables (See Note 1 and 2)
Surges 1.2/50 (8/20)
1 line to ground
Tr/Th us
kV (peak)
B
Telecommunication ports directly connected to indoor cables (See Note 1 and 3)
Surges 1.2/50 (8/20)
0.5 line to ground
Tr/Th us
kV (peak)
B
NOTE 1: Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no test shall be required. NOTE 2: In telecom centers 1kV line to ground and 0.5kV line to line shall be used.
Report No.: 16C2012E-RF-CE-P01V01
Page: 73 of 96
NOTE 3: The test level for telecommunication ports, intended to be connected to indoor cables (longer than 10m) shall be 0.5kV line to ground.
10.4. Test Procedure
The EUT is placed on a table that is 0.8 meter above a metal ground plane measured
1m*1m minimum and 0.65mm thick minimum and projected beyond the EUT by at least
0.1m on all sides. The length of power cord between the coupling device and the EUT
shall be 2m or less.
For AC mains power input ports:
The EUT is connected to the power mains through a coupling device that directly couples
the surge interference signal.
The surge noise shall be applied synchronized to the voltage phase at 00, 900, 1800, 2700
and the peak value of the a.c. voltage wave. (Positive and negative)
Each of Line to Earth and Line to Line is impressed with a sequence of five surge voltages
with interval of 1 minute.
For telecommunication ports:
The signal line of EUT is connected to coupling and decoupling network that directly couples
the surge interference signal.
Only Line to ground is impressed with a sequence of five surge voltages with interval of 1
minute.
10.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 74 of 96
10.6. Test Result Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Inject
Line Polarity
Angle
(degree)
Test Level
(kV)
Test Interval
(second)
Test Result
CriterionObservation Result
L+N + 0 1 60 A Note Pass
L+N - 0 1 60 A Note Pass
L+N + 90 1 60 A Note Pass
L+N - 90 1 60 A Note Pass
L+N + 180 1 60 A Note Pass
L+N - 180 1 60 A Note Pass
L+N + 270 1 60 A Note Pass
L+N - 270 1 60 A Note Pass
LAN + N/A 0.5 60 A Note Pass
LAN - N/A 0.5 60 A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 75 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Inject
Line Polarity
Angle
(degree)
Test Level
(kV)
Test Interval
(second)
Test Result
CriterionObservation Result
L+N + 0 1 60 A Note Pass
L+N - 0 1 60 A Note Pass
L+N + 90 1 60 A Note Pass
L+N - 90 1 60 A Note Pass
L+N + 180 1 60 A Note Pass
L+N - 180 1 60 A Note Pass
L+N + 270 1 60 A Note Pass
L+N - 270 1 60 A Note Pass
LAN + N/A 0.5 60 A Note Pass
LAN - N/A 0.5 60 A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 76 of 96
10.7. Test Photograph Test Mode: Mode 1&2
Description: Surges Test Setup (AC mains power input ports)
Test Mode: Mode 1&2
Description: Surges Test Setup (LAN)
Report No.: 16C2012E-RF-CE-P01V01
Page: 77 of 96
11. Radio frequency common mode
11.1. Test Specification
According to EMC Standard: EN 61000-4-6
11.2. Test Setup
CDN Test Setup
EM Clamp Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 78 of 96
11.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
AC mains power ports (See Note 1 and 2)
Radio frequency
common mode
0.15 - 80
3
80
MHz
V (unmodulated, r.m.s)
% AM (1kHz)
A
DC power ports (See Note 1, 2 and 3)
Radio frequency
common mode
0.15 - 80
3
80
MHz
V (unmodulated, r.m.s)
% AM (1kHz)
A
Signal ports, telecommunication ports, and control ports (See Note 1, 2 and 3)
Radio frequency
common mode
0.15 - 80
3
80
MHz
V (unmodulated, r.m.s)
% AM (1kHz)
A
NOTE 1: If the wanted signal is modulated at 1000Hz, then an audio signal of 400Hz shall be used. NOTE 2: The test shall be performed over the frequency range 150kHz to 80MHz with the exception of the exclusion band for transmitters, and for receivers and duplex transceivers [see clause 4 of EN 301 489-1 V1.9.2 (2011-09)]. NOTE 3: This test shall be additionally performed on signal ports, telecommunication ports, control ports, and DC power ports, of radio equipment and associated ancillary equipment, if the cables may be longer than 3m.
Report No.: 16C2012E-RF-CE-P01V01
Page: 79 of 96
11.4. Test Procedure
The EUT is placed on a table that is 0.8 meter height, and a ground reference plane on
the table, EUT is placed upon table and use a 0,1 m ± 0,05 m insulation between the
EUT and ground reference plane.Where coupling and/or decoupling devices are required,
they shall be located between 0,1 m and 0,3 m from the EUT . This distance is to be measured
horizontally from the projection of the EUT on to the reference ground plane to the coupling
and/or decoupling device.
For AC mains power ports and DC power ports:
The EUT is connected to the power mains through a coupling and decoupling networks for
power supply lines. And directly couples the disturbances signal into EUT.
Used CDN-M2 for two wires or CDN-M3 for three wires.
For signal ports, telecommunication ports, and control ports:
The disturbance signal is through a coupling and decoupling networks (CDN) or
EM-clamp device couples to the signal and telecommunication lines of the EUT.
Condition of Test Remarks
1. Field Strength 3V
2. Radiated Signal AM 80% Modulated with 1kHz
3. Scanning Frequency 0.15 - 80MHz
4 Dwell Time 3 Seconds
5. Frequency Step Size f 1%
11.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 80 of 96
11.6. Test Result Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Frequency
(MHz)
Inject Voltage
(V) Inject Ports Inject Method
Test Result
Criterion Observation Result
0.15-80 3 AC Mains CDN A Note Pass
0.15-80 3 LAN CDN A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 81 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 230V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Frequency
(MHz)
Inject Voltage
(V) Inject Ports Inject Method
Test Result
Criterion Observation Result
0.15-80 3 AC Mains CDN A Note Pass
0.15-80 3 LAN CDN A Note Pass
NOTE: There was no change compared with initial operation during the test.
Report No.: 16C2012E-RF-CE-P01V01
Page: 82 of 96
11.7. Test Photograph Test Mode: Mode 1&2
Description: Radio frequency common mode Test Setup (AC mains power ports)
Test Mode: Mode 1&2
Description: Radio frequency common mode Test Setup (LAN)
Report No.: 16C2012E-RF-CE-P01V01
Page: 83 of 96
12. Voltage dips and interruptions
12.1. Test Specification
According to EMC Standard: EN 61000-4-11
12.2. Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 84 of 96
12.3. Limit
Environmental
phenomenon
Test specification Units Performance
criterion
AC mains power input ports
Voltage dips 0
0.5
% residual
cycle
B
0
1
% residual
cycle
B
70
25
% residual
cycle
B
Voltage
interruptions
0
250
% residual
cycle
C
NOTE: Changes to occur at 0 degree crossover point of the voltage waveform.
12.4. Test Procedure
The EUT is placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m
minimum, and 0.65mm thick minimum, and projected beyond the EUT by at least 0.1m on all
sides. The power cord shall be used the shortest power cord as specified by the manufacturer.
For voltage dips and interruptions test:
The selection of test voltage is based on the rated power range. If the operation range is large
than 20% of lower power range, both end of specified voltage shall be tested. Otherwise, the
typical voltage specification is selected as test voltage.
The EUT is connected to the power mains through a coupling device that directly couples to the
voltage dips and interruption generator.
12.5. Deviation from Test Standard
No deviation.
Report No.: 16C2012E-RF-CE-P01V01
Page: 85 of 96
12.6. Test Result Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 100V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Voltage
% residual
Test Duration
(cycle)
Test Result
Criterion Observation Result
0 0.5 A Note 1 Pass
0 1 A Note 1 Pass
70 25 A Note 2 Pass
0 250 C Note 2 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The system shut down during the test, but can be restored by the user.
Report No.: 16C2012E-RF-CE-P01V01
Page: 86 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 240V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 1: Transmission Data
Voltage
% residual
Test Duration
(cycle)
Test Result
Criterion Observation Result
0 0.5 A Note 1 Pass
0 1 A Note 1 Pass
70 25 A Note 2 Pass
0 250 C Note 2 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The system shut down during the test, but can be restored by the user.
Report No.: 16C2012E-RF-CE-P01V01
Page: 87 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 100V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Voltage
% residual
Test Duration
(cycle)
Test Result
Criterion Observation Result
0 0.5 A Note 1 Pass
0 1 A Note 1 Pass
70 25 A Note 2 Pass
0 250 C Note 2 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The system shut down during the test, but can be restored by the user.
Report No.: 16C2012E-RF-CE-P01V01
Page: 88 of 96
Test Site TR2 Date of Test 2016.12.16
EUT 300Mbps Wi-Fi Range
Extender Test Voltage AC 240V / 50Hz
Temperature 22C Humidity 44%RH
Barometric Pressure 101kPa Test Engineer Ray
Test Mode Mode 2: Standby
Voltage
% residual
Test Duration
(cycle)
Test Result
Criterion Observation Result
0 0.5 A Note 1 Pass
0 1 A Note 1 Pass
70 25 A Note 2 Pass
0 250 C Note 2 Pass
NOTE 1: There was no change compared with initial operation during the test.
NOTE 2: The system shut down during the test, but can be restored by the user.
Report No.: 16C2012E-RF-CE-P01V01
Page: 89 of 96
12.7. Test Photograph Test Mode: Mode 1&2
Description: Voltage dips and interruptions Test Setup
Report No.: 16C2012E-RF-CE-P01V01
Page: 90 of 96
13. Transients and surges
13.1. Test Specification
According to EMC Standard: ISO 7637-2
13.2. Test Setup
13.3. Limit
EUT applying pulses 1, 2a, 2b, 3a, 3b, and 4, using immunity test level Ⅲ. For the
purpose of EMC testing it is sufficient to apply pulses 1, 2a and 4, 10 times each, and
apply the test pulses 3a and 3b for 20 minutes each.
13.4. Test Procedure
Test requirements for 12V DC powered equipment:
Where the manufacturer in his installation documentation requires the radio equipment to have
a direct connection to the 12V main vehicle battery the requirements in a) shall apply.
Where the manufacturer does not require the radio equipment to have a direct connection to
the 12V main vehicle battery the requirements in a) and b) shall apply:
Pulse 3a and 3b, level II, with the test time reduced to 5 min for each;
Pulse 4, level II, 5 pulses, with the characteristics as follows:
Vs = -5V; Va = -2.5V; t6 = 25ms; t7 = 50ms; t8 = 5s; tf = 5ms; pulse cycle time: 60s
Report No.: 16C2012E-RF-CE-P01V01
Page: 91 of 96
Pulse, level II: t1 = 2.5s; 10 pulses;
Pulse 2, level II: t1 = 2.5s; 10 pulses;
Pulse 7, 5 pulses.
Where the manufacturer declares that the radio equipment requires a direct connection to the
main vehicle battery, and therefore the tests in accordance with the requirements b) are not
carried out, this shall be stated in the test report.
Test requirements for 24V DC powered equipment:
Where the manufacturer in his installation documentation requires the radio equipment to have
a direct connection to the 24 V main vehicle battery the requirements in (1) shall apply.
Where the manufacturer does not require the radio equipment to have a direct connection to
the 24 V main vehicle battery the requirements in (1) and (2) shall apply:
(1) Pulse 3a and 3b, level II, with the test time reduced to 5 min for each;
Pulse 4, level II, 5 pulses, with the characteristics as follows:
Vs = -10V; Va = -5V; t6 = 25ms; t7 = 50ms; t8 = 5s; tf = 10ms; pulse cycle time: 60s
(2) Pulse 1a, level II: t1 = 2.5s; Ri = 25Ω; 10 pulses;
Pulse 2b, level II: t1 = 2.5s; Ri = 100Ω; 10 pulses;
Pulse 2, 10 pulses.
Where the manufacturer declares that the radio equipment requires a direct connection to the
main vehicle battery, and therefore the tests in accordance with the requirements d) are not
carried out, this shall be stated in the test report.
Radio and ancillary equipment designed to operate at both DC power voltages shall be
tested in both configurations.
13.5. Deviation from Test Standard
No deviation.
13.6. Test Result
The EUT is not used in the vehicular environment, so it need not to perform this test item.
Report No.: 16C2012E-RF-CE-P01V01
Page: 92 of 96
14. Attachment
EUT Photograph
(1) EUT Photo
(2) EUT Photo
Report No.: 16C2012E-RF-CE-P01V01
Page: 93 of 96
(3) EUT Photo
(4) EUT Photo
Report No.: 16C2012E-RF-CE-P01V01
Page: 94 of 96
(5) EUT Photo
(6) EUT Photo
Report No.: 16C2012E-RF-CE-P01V01
Page: 95 of 96
(7) EUT Photo
(8) EUT Photo
Report No.: 16C2012E-RF-CE-P01V01
Page: 96 of 96
(9) EUT Photo
(10) EUT Photo
The End