Energieeffiziente IE2 Wechselstrommotoren der Zukunft
C. Grabner, 10. April 2013
Climate Change
IEC Standard Development
IE2 Single Phase Motors
Eco-Design Fan Application
Complete Energy Efficiency Portfolio
Content
Seite 1
Climate Change – EU 20-20-20-Goal
Global challenge
CO2-reduction within industry, traffic and home appliances
EU climate protection goals until 2020: - 20% CO2-emission
20% renewable energy + 20% energy efficiency
Seite 2
IEC Standard Development – Committee Draft WG31
Seite 3
CD IEC 60034-30-1 “Efficiency classes of line operated AC motors (IE code)” covers:
Final IE4 values Rated output power 0,12 kW up to 1000 kW Low-voltage motor limitation to 1kV Line-operated single-speed 2, 4 or 6 poles & 8 pole Three phase induction motors Single Phase Motors Line-Start-Magnet-Motors, Line-Start Reluctance-Motors
IE2 Single Phase Motors – Coupled External Circuit Topology
General design remarks Restricted 1~ power grid supply Traditional no efficiency requirements 1~ motor output power is lower than 3~ Starting torque and run-up critical Transient circuit switching and over voltage protection
Coupled external circuit Small or no-load during start, e.g fan >>> Circuit topology A High-load during start, e.g compressor >>> Circuit B
Seite 4
A B
external circuit topologies
IE2 Single Phase Motors – Principal Types of Switches
Mechanical principle Mechanical Centrifugal Switch:
Principle based on mass-spring system Switching state (normally open) is dependent on the changed centrifugal force due to speed
Mechanical Relay: Principle based on electromagnetic forces Mechanical switching in dependency on electrical current or voltage
Electronic start capacitor relay Principle based on analogy electronic circuit Start capacitor is switched off after adjustable time delay, which corresponds to nominal rotary speed after start-up
Seite 5
IE2 Single Phase Motors – Motor Design for Circuit Topology A
Seite 6
A
external circuit topology A
IE2 Single Phase Motors – Motor Design for Circuit Topology B
Seite 7
B
external circuit topology B
IE2 Single Phase Motors – Motor Design B Study 550W
Seite 8
New IE-requirement Type LE71/2C-11+E2 550W, 2poles Efficiency today 60% Future IE2 level of 75% Improvement to be 15%
Main type B activities Low-friction bearing New lamination HP420 Improved cage conductivity (Aluminium instead Silumin die-casting)
B
external circuit topology B
IE2 Single Phase Motors – Motor Design B Study 550W
Seite 9
Centrifugal switching Advantages Reliable and robust (e.g. 500.000 cycles tested) Long-time in-house experience
Disadvantages Abrasion due to moving mechanical components Voluminous axial mounted switching component Extended fan cover
B
external circuit topology B
IE2 Single Phase Motors – Motor Design B Study 550W
B
external circuit topology B
0
1
2
3
4
5
6
7
8
9
10
0 150 300 450 600 750 900 1050 1200 1350 1500
Drehzahl [U/min]
Einh
eite
n
Im[A] 1E = 2,5A Md[Nm] 1E = 1Nm P1[W] 1E = 500W P2[W] 1E = 100W
eta[%] 1E = 10% cosj 1E = 0,1
Starting performance with starting capacitor
Hysterese effects
Steady operational state without
capacitor
IE2 Single Phase Motors – Mechanical Relay Protection Study 1600W
Without Protection Circuitry 230V/60Hz, 1600W CA=40uF, CB=40uF
Seite 11
Suppression of Sparking Effects 230V/60Hz, 1600W CA=40uF, CB=40uF, R1=1Ohm, R2=180kOhm
Sparking cause contact welding
IE2 Single Phase Motors – Electronic Relay Endurance Study 2500W
Seite 12
Electronic relay Advantages
Mounted in terminal box Abrasion free components - No ‘moving’ mechanical parts Logic circuit for zero-voltage detection avoids flashing arcs
Disadvantages Number of cycles restricted - 100.000 cycles qualified Inaccurateness due to potentiometer setting Temperature drift of voltage detection
IE2 Single Phase Motors – Electronic Relay Endurance Study 2500W
Seite 13
B
external circuit topology B
Eco-Design Fan Application – EU regulation 327/2011
COMMISSION REGULATION (EU) No 327/2011
Covers fans driven by electric motors from 125 W to 500 kW
Fan energy efficiency requirement Low eff. level: 1 January 2013 High eff. level: 1 January 2015
ATB is a system supplier, which is responsible for the CE conform product placing in market
Validation done by measurement
Seite 14
Eco-Design Fan Application – System Design Approach
Seite 15
Eco-Design is new & complex topic:
New theoretical calculation procedure necessary with system approach
Software MultiWing Optimizer introduced for efficiency pre-calculation
Eco-Design Fan Application – Fan Validation
Seite 16
Validation method according standard EN ISO 5801
max 100.000 m3/h max 3.000 Pa
New measurement set-up & Calibration procedure for
dp = f(dV(dt) Pel = f(dV(dt)
Eco-Design Fan Application – Type Test Certificate
Seite 17
Type test certificate
Eco-Design Fan Application – Efficiency Comparison
Seite 18
Customized IE2 and IE3 three phase squirrel cage induction motors from 90W to 1,1kW successfully established in the EU market (EU regulation IE3 starts 2017). Smaller IE2 and IE3 range below 750W is not included in the EU regulative yet.
Standard IE2 and IE3 three phase squirrel cage induction motors from 1,5kW up to 375 kW (EU regulation IE3 starts 2015/17) available
New IE2 single phase squirrel cage induction motors will complete range of line operated motor portfolio stepwise until 2014/15
Change to new IE ATB products is economic & reduces costs
Complete Energy Efficiency Portfolio – Change is Economic
Seite 19
Complete Energy Efficiency Portfolio – Further Information
Halle 15 Stand F21
Herzlich Willkommen ...