energy recovery heat pipe heat exchangers...hvac product guide energy recovery heat pipe heat...

16
HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR)

Upload: others

Post on 01-Apr-2020

10 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

HVAC PRODUCT GUIDE

ENERGY RECOVERY HEAT PIPEHEAT EXCHANGERS

WAHX AAHX(WRAP-AROUND) (AIR-TO-AIR)

Page 2: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

THERMAL MANAGEMENT EXPERTS

2

ADVANCED COOLING TECHNOLOGIES, INC. IS A PREMIERTHERMAL MANAGEMENT SOLUTIONS COMPANY.We serve our customers’ thermal management and energyrecovery needs in diverse Markets including Defense, Aerospace, Electronics, HVAC, Medical Devices, Enclosure Cooling and Calibration Equipment. We specialize in providing performance and cost optimized thermal management technologies and solutions that meet the unique needs of each customer.

Our diverse product portfolio maximizes our ability to meet our customers’ performance, cost and reliability requirements. ACT is the only U.S.-based Heat Pipe manufacturer that routinely ships Heat Pipe products for terrestrial, spacecraft, and high temperature applications.

Our HVAC Wrap-Around and Air-to-Air Heat Exchanger products are in operation throughout the world, improving energy e�ciencies of building HVAC systems and industrial processes.

ACT is strongly committed to our customers, employees, and community. Innovation, Teamwork and Customer Care are the core values that drive the continuous growth of our company.

TABLE OF CONTENTS

HVAC Heat Pipe Operation and ACT HVAC Energy Recovery Systems pg. 3

Wrap-Around Heat Pipe Exchangers (WAHX) pg. 4-5

WAHX Heat Pipe with Control pg. 6-7

Air-to-Air Heat Pipe Exchangers (AAHX) pg. 8-10

Online Selection Tools pg. 11

WAHX Traditional Dimensions pg. 12

WAHX Split Loop Thermosyphon Dimensions pg. 13

AAHX Traditional Dimensions pg. 14

AAHX Split Loop Thermosyphon Dimensions pg. 15

WWW.1-ACT.COM/HVAC

Page 3: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

HVAC HEAT PIPE OPERATION

ACT ENERGY RECOVERY TYPES

PASSIVE AIR-TO-AIR HEAT

PIPE EXCHANGER (AAHX)

3

HEAT IN

HEAT OUT

HEAT IN HEAT OUT

EVAPORATOR CONDENSER

Working fluid vapor flows through center

ACT HVAC ENERGY RECOVERY SYSTEMS

WRAP-AROUND HEAT PIPE

EXCHANGERS (WAHX)

HVAC HEAT PIPE OPERATING PRINCIPLEHeat pipes function by absorbing heat at the evaporator end of the cylinder, boiling and converting the fluid to vapor. The vapor travels to the condenser end, rejects the heat, and condenses to liquid. The condensed liquid flows back to the evaporator, aided by gravity.

The phase change cycle continues as long as there is heat (warm outside air) at the evaporator end of the heat pipe. This process occurs passively (no external electrical energy required).

Page 4: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

HOW DOES A WRAP-AROUND HEAT PIPE HEAT EXCHANGER WORK?

102°/77.8° 15.6° 86.4°/73.7° 52.5°/52.4° 15.5° 68.0°/58.6°

92°/77.7° 15.2° 76.8°/69.4° 52.5°/52.4° 15.1° 67.6°/58.5°

82°/68.8° 11.3° 70.7°/65.2° 52.5°/52.4° 11.3° 63.8°/57.0°

72°/63.7° 7.5° 64.5°/61.0° 52.5°/52.4° 7.5° 60.0°/55.5°

62°/56.4° 3.6° 58.4°/55.0° 52.5°/52.4° 3.6° 56.1°/54.0°

52°/52.4° 0.0° 52.5°/52.4° 52.5°/52.4° 0.0° 52.5°/52.4°

DELTA T° DELTA T°OUTSIDE AIRHEAT PIPEPRE-COOL

COOLINGCOIL

HEAT PIPERE-HEAT

AHU: 20,000 CFM4 Rows of Heat Pipes12 Fins per inch

WAHX CONFIGURATIONS

PIPE TO PIPE CONNECTION EVERY ROW EVERY PIPE

• Any Coil Dimensions• Stackable• Controllable

SPLIT LOOP THERMOSYPHON 2 PIPES PER ROW

• Any Length Coil• Max 37” Fin Height• Stackable• Controllable

WRAP-AROUND HEAT PIPE (WAHX)

4WWW.1-ACT.COM/HVAC

Page 5: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

5

BENEFITS

•Energy Savings •Free pre-cooling (lower tonnage AHU systems) •Free re-heat (no electric, steam or hot water cost)•Passive System •No maintenance •No moving parts (except for control valves when applied)•Enhanced Dehumidification •Lower entering air conditions (ex: 95º to 85º) •Lower cooling coil discharge temperature•Neutral Air Discharge (free re-heat)•Meets Energy Code Requirements for Chilled Water DOAS AHUs•Lower Static vs. Other Energy Recovery Types

FEATURES

•1/2” Rifled Copper Tubes for Enhanced Thermal Performance • Aluminum Fins (8-14 Fpi)•Galvanized Steel Casing•Factory Installation, Field Installation or AHU Manufacturer Installation•R-134a•Up to 10 Rows

OPTIONS

•Up to 1” Coil Tubes (Copper or Aluminum)•Stainless Steel Casing•Multiple Fin Types & Materials•Controllable (Active or Passive)•Coil Coating (E-Coat or Heresite)•R-410A

WRAP-AROUND HEAT PIPE (WAHX)

Page 6: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

6

WAHX HEAT PIPE WITH CONTROL

50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

MBH

25

50

75

100

125

150

175

200

WRAP-AROUND HEAT PIPE PERFORMANCEMEETING REHEAT AND DESIGN POINT TARGETS WITH ADDITIONAL ROWS

OUTDOOR TEMPERATURE °F

NUMBER O

F H

OURS/YR AT T

ERMPERAT

URE

500

1,000

1,500

2,000

2,500

FORT LAUDERDALE, FLORIDAANNUAL BIN TEMPERATURE DATA

Chart 1

Chart 2

For this example the largestband of energy savings occurs

within the circle.

2 ROWS3 ROWS4 ROWS5 ROWS6 ROWS

92° F Design Point

65° F Reheat Goal

Annual Data - Running Hours 24 Hrs/Day 7 Days/Week (Note: Temperatures below 57.5° F are not calculated).

System Assumptions: 17,500 CFM system, operating in Fort Lauderdale Florida, Cooling Coil at 55° FDB/54.9°FWB.

TECHNICAL PARAMETERS UTILIZED:

AVOID OVER-COOLING THE SPACE WHILE MAXIMIZING SAVINGS

OUTDOOR TEMPERATURE °F

50° 55° 60° 65° 70° 75° 80° 85° 90° 95°

WWW.1-ACT.COM/HVAC

Page 7: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

ACTIVE THERMAL CONTROL VALVE ACT-TAV

7

WAHX HEAT PIPE WITH CONTROL

CONSIDER ACT’S CONTROL VALVES FOR OPTIMIZED WRAP-AROUND HEAT PIPE ENERGY PERFORMANCE

In order to capture and transfer even more energy, ACT’s control valve options increase the ability of the WAHX to have a wider range of energy savings operation at lower entering air temperatures. ACT control valve options permit additional heat pipe rows, resulting in higher capacity WAHX systems with the capability of stopping refrigerant flow in selected rows to maintain a specified discharge temperature. WAHX control maximizes energy savings as the outside air temperature fluctuates.

ACT-TPV is available in 5° temperature increments. No control signal is required (passive operation).

TAV controlled by ACT panel and stages can be controlled by BMS.

PASSIVE THERMAL CONTROL VALVE (ACT-TPV)

Relief Spring

Actuator BodyReturn Spring

Tapered Seal

Actuator Guide

Partent Pending

SPLIT LOOP THERMOSYPHON WITH 100%

REHEAT CONTROL WRAP-AROUND (ACT-SLT)

One valve per row, on/off or modulating, controlled by the Building Management System (BMS) based on the discharge air temperature.

Page 8: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

8WWW.1-ACT.COM/HVAC

Btu/hr

Btu/hrSAVIN

GS

SAVIN

GS

The ACT Heat Pipe Heat Exchanger can be oriented to match the AHU or duct work.

AIR-TO-AIR HEAT PIPE HEAT EXCHANGER INSTALLATION OPTIONS

FLAT

VERTICAL HORIZONTAL

SPLIT LOOP THERMOSYPHON

AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS (AAHX)

HOW DOES AN AAHX WORK?

Captures space exhaust air energy and transfers via passive heat pipe to pre-cool or pre-heat incoming outside air.

Every ACT AAHX is designed to yield the optimal effectiveness in BTU/hr savings. ACT’s energy recovery systems are custom engineered for each project to yield the best ratio of cost versus performance. Typical system payback is under two years.

Page 9: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

9

BENEFITS•Energy Savings •Pre-cool and pre-heat with up to 75% effectiveness •During summer operation with 75° exhaust air, the AAHX can pre-cool

entering 95° outside air down to 80°, saving on cooling load capacity •During winter operation with 70° exhaust air, the AAHX can pre-heat

entering 0° outside air up to 52°, saving on heating load capacity•Passive System •No maintenance •No moving parts•Configuration •Any height or length (not round) •Splittable •Exhaust and supply can be different lengths and CFMs •From 2” to 15” in depth, requiring minimal AHU space •No cross air contamination

FEATURES

• 1/2” Rifled Copper Tubes for Enhanced Thermal Performance• Aluminum Fins (8-14 Fpi)•Galvanized Steal Casing•Factory Installation, Field Installation or AHU Manufacturer Installation• R-134a•Up to 10 Rows

OPTIONS

•Up to 1” Coil Tubes (Copper or Aluminum)•Stainless Steal Casing•Multiple Fin Types & Materials•Controllable •Coil Coating (E-Coat or Heresite)•Tilt Option•Pump Systems•R-410A

AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS (AAHX)

Page 10: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

10

PUMPED AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS

ENERGY RECOVERY - PUMPED SYSTEM

• Summer/Winter Energy Recovery (pumps operate for one or both seasons)

• System can be split between ducts up to 30’+

• Low Pressure Drop

• Sizes up to 25,000 CFM+

• Positive Recovery Efficiency Ratio (RER)

• Low RPM pump configuration for long life

CONTROL HEAT PIPE AAHX FUNCTION BY TILTING

Tilting the HP-AAHX will transfer operation from summer to winter by assuring the warm air stream is lower than the cold air stream.

Features included: Steel housing, integrated flex duct, dual contacts, heavy duty actuator, and simple AHU installation.

WWW.1-ACT.COM/HVAC

TILT AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS

EXHAUST AIR

OUTSIDEAIRAAHX

Page 11: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

11

PUMPED AIR-TO-AIR HEAT PIPE HEAT EXCHANGERS

ONLINE SELECTION TOOLS

The WAHX and AAHX Selection Tools are intended to provide the designer with the capability to perform a preliminary design selection and to evaluate performance at various design conditions. It is also intended to be a tool to communicate engineering requirements and design targets to ACT for additional calculations and/or for preparing a quotation.

The WAHX Selection Tool can be set to English or Metric units. Multiple input variables can be selected from CFM’s to DB/WB combinations for incoming Air, Active Coil and Supply Air to mention a few.

There are two useful output options for each Selection Tool. One is “Print to PDF”, which will capture the on screen data in a savable format. The other is a “Submit to ACT” which will capture the screen data, including the product information that the user enters, and sends it to an ACT engineer for further assistance or quotation.

www.1-ACT.com/HVAC/WAHX www.1-ACT.com/HVAC/AAHX

WAHX SELECTION TOOL AAHX SELECTION TOOL

Page 12: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

12WWW.1-ACT.COM/HVAC

ACT W

RAP-AROUND H

EAT

PIP

E H

EAT

EXCHANGER D

IMENSIONS

WAHX TRADITIONAL DIMENSIONS

W

FH

FL

D

OA

H

E1

- E2:

Sid

e Fl

ange

E3

- E4:

Top

- B

otto

m F

lang

e

FH: F

in H

eigh

t

FL: F

in L

engt

h

Fron

t Vie

w D

imen

sion

Tab

le

Fin

Hei

ght “

MU

ST”

be

in m

ultip

les

of 1

.25”

Opt

iona

l

Min

imum

of 1

.5”

or a

s sp

ecifi

edM

inim

um o

f 1.0

” or

as

spec

ified

(W) C

oil W

idth

Tab

le b

y N

umbe

r of

Row

s

WRow

s1

23

45

67

89

10

1.5

” 3

.0”

4.0

” 5

.0”

6.0

” 7

.0”

8.0

” 9

.25”

10.

5” 1

1.5”

OAW

: Tot

al C

oil S

paci

ng

Opt

iona

l

Opt

iona

lO

AL:

Tot

al L

engt

h

D: R

etur

n Tu

be D

epth

See

tabl

e fo

r min

imum

or a

s sp

ecifi

ed

E1

E2

E3 E4

OA

H: T

otal

Hei

ght

Opt

iona

l

(D) R

etur

n Tu

be D

epth

Tab

le b

y N

umbe

r of

Row

s

DRow

s1

23

45

67

89

10

2.0

”2.

0”2.

75”

3.5”

4.25

”4.

25”

5.0”

5.0

OAW

GA

P

GA

PO

ptio

nal

2.75

”3.

5”

W: C

oil W

idth

See

tabl

e fo

r min

imum

or a

s sp

ecifi

ed

Not

e: D

raw

ings

are

not

to s

cale

Ener

gy R

ecov

ery C

oil S

ide V

iew

Page 13: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

WWW.1-ACT.COM/HVAC 13

WAHX SPLIT LOOP THERMOSYPHON DIMENSIONS

OA

L

OA

H

GA

P

OAW

W

D

FL

E1

E2

E3

E4

FHO

AH

OA

L

DC

AS

ING

Not

e: D

raw

ings

are

not

to s

cale

E1

- E2:

Sid

e Fl

ange

E3

- Bot

tom

Fla

nge

FH: F

in H

eigh

t,*M

ax. 3

6.0”

FL: F

in L

engt

h

Fron

t Vie

w D

imen

sion

Tab

le

Opt

iona

l

Opt

iona

l

Min

imum

of 1

.00”

or a

s sp

ecifi

edM

inim

um o

f 4.5

0”or

as

spec

ified

OAW

: Tot

al C

oil S

paci

ng

“MU

ST”

be in

mul

tiple

s of

1.2

5”Opt

iona

lO

AL:

Tot

al L

engt

h

D: R

etur

n Tu

be D

epth

See

tabl

e fo

r min

imum

or a

s sp

ecifi

ed

OA

H: T

otal

Hei

ght

FH +

8.5

0”

GA

PO

ptio

nal

W: C

oil W

idth

See

tabl

e fo

r min

imum

or a

s sp

ecifi

ed

E4:

Bot

tom

Fla

nge

Min

imum

of 4

.00”

(D)R

etur

n Tu

be D

epth

Tab

le b

y N

umbe

r of

Row

s

No

Con

trol -

D

Row

s1

23

45

67

89

10

2.0

”4.

0”5.

0”9.

0”10

.0”

11.0

”12

.0”

14.

0”7.

0”8.

0”

4.0

”5.

50”

6.75

”13

.5” 1

5.75

”18

.0”

20.2

5” 2

2.5”

9.0”

11.2

5”W

ith C

ontro

l - D

(W)C

oil W

idth

Tab

le b

y N

umbe

r of

Row

s

WRow

s1

23

45

67

89

10

2.0

” 3

.5”

4.5

” 6

.0”

7.0

” 8

.0”

9.0

” 1

0.0”

11.

0” 1

2.0”

*N

ote:

Fin

Hei

ght o

ver 3

6.0”

mus

t be

stac

ked

ACT S

PLIT L

OOP T

HERMOSYPHON W

RAP-AROUND H

EAT

PIP

E H

EAT

EXCHANGER D

IMENSIONS

Ener

gy R

ecov

ery C

oil S

ide V

iew

Page 14: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

ACT AIR

-TO-AIR H

EAT

PIP

E H

EAT

EXCHANGER DIMENSIONS

ACT-HP-AAHX SERIES

Not

e: D

raw

ings

are

not

to s

cale

W

OA

HFH

FL1

FL2

C

E2

E1

E3

E4

FW

W W

FW

FW

Fron

t Vie

w

Side

Vie

w 2

- 4

- 6 R

ow H

eat P

ipe

Hea

t Exc

hang

ers

E1

- E2:

Sid

e Fl

ange

C: C

ente

r Div

ider

Wid

th

E3

- E4:

Top

- B

otto

m F

lang

e

FH: F

in H

eigh

t

FL1:

Fin

Len

gth

FL2:

Fin

Len

gth

Fron

t Vie

w D

imen

sion

Tab

le

4 R

OW

6 R

OW

2 R

OW

Fin

Hei

ght “

MU

ST”

be

in m

ultip

les

of 1

.25”

Opt

iona

l

Opt

iona

l

Ttyp

ical

ly 2

.0” o

r as

spe

cifie

dM

inim

um o

f 1.5

” or

as

spec

ified

Min

imum

of 1

.0”

or a

s sp

ecifi

ed

Side

Vie

w D

imen

sion

Tab

le b

y N

umbe

r of

Row

s

WRow

s

FW

12

34

56

78

9

10

1.0

8”2.

17”

3.25

”4.

33”

5.42

”6.

49”

7.58

”8.

66”

9.75

” 1

0.83

1.5

” 3

.0”

4.0

” 5

.0”

6.0

” 7

.0”

8.0

” 9

.25”

10.

5” 1

1.5”

AAHX TRADITIONAL DIMENSIONS

WWW.1-ACT.COM/HVAC 14

Page 15: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

ACT S

PLIT L

OOP T

HERMOSYPHON AIR

-TO-AIR H

EAT

PIP

E H

EAT

EXCHANGER DIMENSIONS

Fron

t Vie

w

FW

W

OA

HFH

2

FL2

E2

E1

E5 E6

FW

W W

FW

Side

Vie

w E

xam

ples

of 2

- 4

- 6 R

ow H

eat P

ipe

Hea

t Exc

hang

ers

E1,

E2,

E3,

E4:

Sid

e Fl

ange

s

C: C

ente

r Div

ider

Wid

th

E5

- Top

Fla

nge

FH 1

& 2

: Fin

Hei

ght M

axim

um

FL1:

Fin

Len

gth

FL2:

Fin

Len

gth

Fron

t Vie

w D

imen

sion

Tab

le

4 R

OW

6 R

OW

2 R

OW

Fin

Hei

ght O

ptio

nal

Typi

cally

>4.

00” o

ras

spe

cifie

dM

inim

um o

f 1.0

0”

or a

s sp

ecifi

ed

Min

imum

of 4

.50”

or a

s sp

ecifi

ed

Side

Vie

w D

imen

sion

Tab

le b

y N

umbe

r of

Row

s

WRow

s

FW

12

34

56

78

910

1.0

8”2.

17”

3.25

”4.

33”

5.42

”6.

49”

7.58

”8.

66”

9.75

”10

.83”

2.0

0” 3

.50”

4.5

0” 6

.00”

7.0

0” 8

.00”

9.0

0” 1

0.0”

11.

0” 1

2.0”

FL1

C

E3

E4

Fin

Leng

th O

ptio

nal

be in

mul

tiple

s of

1.2

5”Fi

n Le

ngth

Opt

iona

lbe

in m

ultip

les

of 1

.25”

FH 1

E6

- Bot

tom

Fla

nge

Min

imum

of 4

.00”

or

as

spec

ified

Not

e: D

raw

ings

are

not

to s

cale

Mus

t Sta

ck A

AH

X o

ver 3

7.5”

* N

ote:

AA

HX

-Spl

it Lo

op T

herm

osyp

hon

Sys

tem

s c

an n

ot e

xcee

d 36

.0” i

n fin

hei

ght.

Uni

ts c

an b

e st

acke

d

AAHX TRADITIONAL DIMENSIONS AAHX SPLIT LOOP THERMOSYPHON DIMENSIONS

15

Page 16: ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS...HVAC PRODUCT GUIDE ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS WAHX AAHX (WRAP-AROUND) (AIR-TO-AIR) ... Online Selection Tools pg. 11

ADVANCED COOLING TECHNOLOGIES 1046 New Holland AvenueLancaster, PA 17601, USA

Phone: 717.295.6061 Fax: 717.295.6064

ISO 9001 & AS9100 Certified ITAR Registered

www.1-ACT.com/HVAC