engine driven cogeneration...small natural gas driven chp units* key features & benefits total...
TRANSCRIPT
![Page 1: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/1.jpg)
Engine-Driven Cogeneration
Product Data Sheets
Micro T Series 35-55kW Cento T Series 100-200kW Cento M Series 80-270kW
Cento L Series 230-520kW
Quanto Series 800-2000kW
![Page 2: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/2.jpg)
TEDOM MICRO T35 Small Natural Gas Driven CHP Units*
Key Features & Benefits
Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for CHP have continuous demand for both electricity and hot water or heating.
* Biogas Micro T35 units are also available
![Page 3: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/3.jpg)
Micro T35 - Small Natural Gas CHP Units
For more information please visit
www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
4 With lower emissions option
Fuel Natural Gas
Engine TGE V3800 - manufactured by Tedom
Generator Asynchronous - AS 225 - manufactured by Zanardi
Synchronous - ATEW 34/4 1S - manufactured by Zanardi
Electrical Output
35 kW 35 kW
SP AP
208 VAC / 480 VAC, 3PH , 60 HZ
Maximum Heat Output 246,300 Btu/hr 238,500 Btu/hr
Electrical Efficiency (HHV)2 27.6% 28.6%
(LHV)3 30.9% 32.0%
Overall Efficiency (HHV)2
84.6% 85.7%
(LHV)3 94.8% 95.5%
Fuel Input (HHV)2 432,200 Btu/hr 417,800 Btu/hr
(LHV)3 385,000 Btu/hr 375,000 Btu/hr
Required Gas Pressure 4-40” wc
Hot Water Flow 13.6 gpm 13.16 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 1.0 lb/MWh (0.15 lb/MWh)4 1.0 lb/MWh (0.15 lb/MWh)4
CO 2.0 lb/MWh (0.15 lb/MWh)4 2.0 lb/MWh (0.15 lb/MWh)4
VOC 2 lb/MWh 2 lb/MWh
Dimensions 76.8” L x 32.4” W x 72.3” H
Weight 2,426 lbs
Operating Temperature Range 50° F / 95° F
Acoustic Level * Sound Enclosure 62 dBa
Exhaust Gas 59 dBa
Specifications: 1
NYSIR Certified
NFPA-70 Certified
UL 2200 Certified
CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified
Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 4: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/4.jpg)
TEDOM MICRO T35 Small Biogas Driven CHP Units*
Key Features & Benefits
Total efficiency of 91% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Natural Gas Micro T35 units are also available
![Page 5: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/5.jpg)
Micro T35 - Biogas CHP Units
For get more information please visit
www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
Specifications: 1
Fuel Biogas
Engine TGE V3800 - manufactured by Tedom
Generator Asynchronous - AS 225 - manufactured by Zanardi
Synchronous - ATEW 34/4 1S - manufactured by Zanardi
Electrical Output
27 kW
SP & AP
208 VAC and480 VAC, 3PH , 60 HZ
Maximum Heat Output 171,972 Btu/hr
Electrical Efficiency (HHV)2 29.1%
(LHV)3 32.0%
Overall Efficiency (HHV)2 83.4%
(LHV)3 91.6%
Fuel Input (HHV)2 316,670 Btu/hr
(LVH)3 288,000 Btu/hr
Required Gas Pressure 4-40” wc
Hot Water Flow 9.6 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 6.4 lb/MWh (3 lb/MWh)4
CO 15.5 lb/MWh (4.7 lb/MWh)4
VOC 3 lb/MWh
Dimensions 76.8” L x 32.4” W x 72.3” H
Weight 2,426 lbs
Operating Temperature Range 50° F / 95° F
Acoustic Level * Sound Enclosure 62 dBa
Exhaust Gas 59 dBa
NYSIR Certified
NFPA-70 Certified
UL 2200 Certified
CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified
Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
1 All specifications are +/- 5% and are subject to change without notice.
2 HHV of 695 Btu/scf (25.9 MJ/Nm3)
3 LHV of 628 Btu/scf (23.4 MJ/Nm3)
4 With lower emissions option
![Page 6: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/6.jpg)
TEDOM MICRO T55 Combined Heat & Power Units
Key Features & Benefits
Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for CHP have continuous demand for both electricity and hot water or heating.
![Page 7: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/7.jpg)
Micro T55 - Combined Heat & Power Units
For get more information or to request a free site-specific economic analyses please visit
www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of
TEDOM and Tecogen
TTCogen 45 First Avenue, Waltham, MA 02451
Fuel Natural Gas
Engine MAN 0834 E302
Generator Synchronous - ATEW 34/4 1L - manufactured by Zanardi
Electrical Output 55 kW
208VAC / 480 VAC, 3PH , 60 HZ
Maximum Heat Output 339,740 Btu/hr
Electrical Efficiency (HHV)2 30.7%
(LHV)3 34.1%
Overall Efficiency (HHV)2 85.8%
(LHV)3 95.8%
Fuel Input (HHV) (HHV)2 612.300 Btu/hr
(LHV)3 549,360 Btu/hr
Required Gas Pressure 4-40” wc
Hot Water Flow 20.6 gpm
Maximum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 1.0 lb/MWh (0.15 lb/MWh)4
CO 2.0 lb/MWh (0.15 lb/MWh)4
VOC 2.0 lb/MWh
Dimensions 100.4” L x 35.0” W x 68.1” H
Weight 3,969 lbs
Operating Temperature Range 50° F / 95° F
Acoustic Level * Sound Enclosure 65 dBa
Exhaust Gas 62 dBa
Specifications: 1
1 All specifications are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
4 With lower emissions option
NYSIR Certified
NFPA-70 Certified
UL 2200 Certified
CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified
Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 8: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/8.jpg)
TEDOM CENTO T100, T150 & T200 Natural Gas Driven CHP Units*
Key Features & Benefits
Total efficiency of 88% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Biogas CENTO CHP units are also available
![Page 9: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/9.jpg)
Cento Series - Natural Gas Driven CHP Units
For get more information please visit www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
4 With lower emissions option
Specifications: 1
Series Cento T100 Cento T150 Cento T200
Engine
TG 100 G8V
NX 86
TG 105 G8V
NX 88
TG 150 G8V
NX 86
TG150 G8V
NX 88
TG 200 G8V
TW 88
Lean Burn Rich Burn Lean Burn Rich Burn Lean Burn
manufactured by Tedom
Generator Leroy Somer LSA 44.3 L10/L12 Leroy Somer LSA 46.2 L6
Leroy Somer
LSA 46.2 VL12
manufactured by Mecc Alte
Electrical Output 93 kW 99 kW 144 kW 146 kW 192 kW
208 VAC / 480 VAC, 3PH, 60 Hz
Maximum Heat Output 504,995 Btu/hr 590,300 Btu/hr 723,370 Btu/hr 771,145 Btu/hr 870,095 Btu/hr
Electrical Efficiency (HHV)2 30.3% 29.1% 31.9% 31.8% 33.9%
(LHV)3 33.9% 32.5% 35.7% 35.5% 37.8%
Overall Efficiency (HHV)2 78.5% 80.0% 79.0% 81.0% 78.9%
(LHV)3 87.9% 89.5% 88.2% 90.6% 88.3%
Fuel Input (HHV)2 1,045,070 Btu/hr 1,159,490 Btu/hr 1,537,092 Btu/hr 1,566,605 Btu/hr 1,933,760 Btu/hr
(LHV)3 934,928 Btu/hr 1,037,292 Btu/hr 1,375,094 Btu/hr 1,402,391 Btu/hr 1,729,957 Btu/hr
Required Gas Pressure 8-40” wc
Hot Water Flow 28.5 gpm 33.3 gpm 41.2 gpm 42.9 gpm 45.9 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 1.4 lb/MWh 1.2 lb/MWh ( 0.15)4 1.4 lb/MWh 1.2 lb/MWh ( 0.15)4 1.5 lb/MWh
CO 2.2 lb/MWh 2.4 lb/MWh ( 0.15)4 2.0 lb/MWh 2.4 lb/MWh ( 0.15)4 2.3 lb/MWh
VOC 0.9lb/MWh 0.9 lb/MWh 0.9 lb/MWh 0.9 lb/MWh 0.9 lb/MWh
Enclosure Options
(open modules are also available) Dimensions Max. Weight
Operating
Temp. Range
Acoustic Levels* - dBa @ 1M
Standard / Ventilated / Exhaust Gas
Centro T100 & T150 Sound Enclosure 174” L x 59.1” W x 87.6” H 9,822 lbs 50°-95° F 77 / 84 / 84
Cento T100 & T150 Container 212.6” L x 98.4” W x 267.7” H 18,222 lbs -68°-95° F 62 / 62 / 62
Cento T200 Sound Enclosure 174” L x 59.1” W x 87.6” H 10,186 lbs 50°-95° F 78 / 89 / 84
Cento T200 Container (@ 10M)* 218.5” L x 118.1” W x 255.9” H 20,030 lbs -68°-95° F 63 / 63 / 63
NYSIR Certified NFPA-70 Certified UL 2200 Certified CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 10: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/10.jpg)
TEDOM CENTO T100, T150 & T200 Biogas Driven CHP Units*
Key Features & Benefits
Total efficiency of 86% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Natural Gas CENTO CHP units are also available
![Page 11: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/11.jpg)
Cento Series - Biogas Driven CHP Units
For get more information please visit
www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 695 Btu/scf (25.9 MJ/Nm3)
3 LHV of 628 Btu/scf (23.4 MJ/Nm3)
4 With lower emissions option
Specifications: 1
Series Cento T100 Cento T150 Cento T200
Engine
TB 100 G8V
NX 86
TG 150 G8V
TX 86
TB 200 G8V
TW 86
Lean Burn Lean Burn Lean Burn
manufactured by Tedom
Generator Leroy Somer LSA 44.3 L10/L12 Leroy Somer LSA 46.2 L6 Leroy Somer LSA 46.2 VL12
manufactured by Mecc Alte
Electrical Output 94 kW 140 kW 191 kW
208 VAC / 480 VAC, 3PH, 60 Hz
Maximum Heat Output 504,997 Btu/h 731,745 Btu/hr 890,942 Btu/hr
Electrical Efficiency (HHV)2 30.3% 30.9% 33.3%
(LHV)3 33.5% 34.2% 36.8%
Overall Efficiency (HHV)2 78.0% 78.1% 78.8%
(LHV)3 86.3% 86.5% 87.2%
Fuel Input (HHV)2 1,057,330 Btu/h 1,546,550 Btu/h 1,956,510 Btu/h
(LHV)3 955,400 Btu/hr 1,396,750 Btu/hr 1,766,241 Btu/hr
Required Gas Pressure 20-40” wc
Hot Water Flow 27.9 gpm 42.0 gpm 46.8 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 6 lb/MWh (3 lb/MWh)4 6 lb/MWh (3 lb/MWh)4 6 lb/MWh (3 lb/MWh)4
CO 15 lb/MWh (4.7 lb/MWH)4 15 lb/MWh (4.7 lb/MWh)4 15 lb/MWh (4.7 lb/MWh)4
VOC 3 lb/MWh 3 lb/MWh 3 lb/MWh
Enclosure Options Dimensions Max. Weight Operating
Temp. Range
Acoustic Levels* - dBa @ 1M
Standard / Ventilated / Exhaust Gas
Centro T100 & T150 Sound Enclosure 174” L x 59.1” W x 87.6” H 9,822 lbs 50°-95° F 77 / 84 / 84
Cento T100 & T150 Container 212.6” L x 98.4” W x 267.7” H 18,222 lbs -68°-95° F 62 / 62 / 62
Centro T200 Sound Enclosure 174” L x 59.1” W x 87.6” H 10,186 lbs 50°-95° F 78 / 89 / 84
Cento T200 Container (@ 10M)* 218.5” L x 118.1” W x 255.9” H 20,030 lbs -68°-95° F 63 / 63 / 63
NYSIR Certified
NFPA-70 Certified
UL 2200 Certified
CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified
Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 12: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/12.jpg)
TEDOM CENTO M80 & M270 Natural Gas Driven CHP Units*
Key Features & Benefits
Total efficiency of 87% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Biogas CENTO CHP units are also available
![Page 13: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/13.jpg)
Cento Series - Natural Gas Driven CHP Units
For get more information please visit
www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
4 Lower emissions are available
Specifications: 1
Series Cento M80 Cento M270
Engine MAN 0836 E302 MAN E2842 E312
Manufactured by MAN Company
Synchronous Generator LSA 44.2 L12 LSA 46.2 VL12
manufactured by Leroy Somer
Electrical Output 80 kW 268 kW
480 VAC, 3PH, 60 Hz
Maximum Heat Output 426.518 Btu/hr 1,419,452 Btu/hr
Electrical Efficiency (HHV)2 30.6% 31.8%
(HHV)3 34.2% 35.5%
Overall Efficiency (HHV)2 78.3% 81.2%
(LHV)3 87.6% 90.7%
Fuel Input (HHV)2 893,220 Btu/hr 2,874,160 Btu/hr
(LHV)3 798,440 Btu/hr 2,572,760 Btu/hr
Required Gas Pressure 8-40” wc
Hot Water Flow 23.8 gpm 79.3 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 2.9 lb/MWh (0.15 lb/MWh)4 3.5 lb/MWh
CO 5.9 lb/MWh (0.15 lb/MWh)4 4.4 lb/MWh
VOC 2 lb/MWh 2 lb/MWh
Enclosure Options Dimensions Max. Weight Operating
Temp. Range
Acoustic Levels* - dBa @ 1M
Standard / Ventilated / Exhaust Gas
Centro M80 143.7” L x 43.3” W x 74.8” H 4,619 lbs 50°-95° F 67 / 78 / 85
Cento M270 181.1” L x 78.7” W x 118.1” H 17,859 lbs -50°-95° F 75 / 84 / 80
Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 14: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/14.jpg)
TEDOM CENTO L230, L320 & L520 Natural Gas Driven CHP Units*
Key Features & Benefits
Total efficiency of 87% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Biogas CENTO CHP units are also available
![Page 15: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/15.jpg)
Cento Series - Natural Gas Driven CHP Units
For get more information please visit www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
Specifications: 1
Series Cento L230 Cento L320 Cento L520
Engine G946 G9508 G9512
manufactured by Liebherr
Generator LSA 47.2 VS2 LSA 47.2 M7 LSA 49.1 M^
manufactured by Leroy Somer
Electrical Output 235 kW 324 kW 520 kW
480 VAC, 3PH, 60 Hz
Maximum Heat Output 1,071,410 Btu/hr 1,637,825 Btu/hr 2,398,735 Btu/hr
Electrical Efficiency 33.7% (HHV)2 37.7% (LHV)3 31.7% (HHV)2 35.4% (LHV)3 33.5% (HHV)2 37.4% (LHV)3
Overall Efficiency 78.7% (HHV)2 88.0% (LHV)3 78.7% (HHV)2 88.0% (LHV)3 78.7% (HHV)2 88.0% (LHV)3
Fuel Input (HHV)2 2,380,010 Btu/h 3,486,105 Btu/h 5,301,630 Btu/hr
(LHV)3 2,129,170 Btu/hr 3,118,700 Btu/hr 4,742,880 Btu/hr
Required Gas Pressure 8-38” wc (container enclosure 20-40”)
Hot Water Flow 60.2 gpm 86.4 gpm 128.4 gpm
Minimum Entering Water Temperature 104° F
Maximum Leaving Water Temperature 194° F
Emissions
NOx 3.2 lb/MWh 3.2 lb/MWh 3.2 lb/MWh
CO 2.0 lb/MWh 2.0 lb/MWh 2.0 lb/MWh
VOC 2.0 lb/MWh 2.0 lb/MWh 2.0 lb/MWh
Enclosure Options Dimensions Max. Weight Operating
Temp. Range
Acoustic Levels* - dBa @ 1M
Standard / Ventilated / Exhaust Gas
Cento L230 - Open Module 189” L x 61” W x 89” H 12,038 lbs 50°-95° F 92 / n/a / 65
- Sound Enclosure 206” L x 61” W x 89” H 12,920 lbs 50°-95° F 75 / 85 / 65
- Container (@ 10M) 255.9” L x 141.7” W x 236.2” H 20,857 lbs -68°-95° F 63 / 63 / 63
Cento L320 - Open Module 197” L x 81” W x 106” H 16,789 lbs 50°-95° F 93 / n/a / 65
- Sound Enclosure 222.4” L x 81” W x 106” H 19,171 lbs 50°-95° F 76-71* / 86-76* / 65
- Container (@10M) 265.7” L x 204.7” W x 224.4” H 37,481 lbs -68°-95° F 75* / 75* / 75*
Cento L520 - Open Module 212.6” L x 92.5” W x 106.3” H 19,468 lbs. 50°-95° F 98 / n/a / 65
- Sound Enclosure 222.4” L x 100.4” W x 108.3” H 21,850 lbs. 50°-95° F 78-73* / 90-79*
- Container (@ 10M) 265.8” L x 204.7” W x 224.4” H 38,143 lbs. -68°-95° F 65 / 65 / 75*
* Lower acoustic levels (Silent and Super Silent) are not standard but may be ordered
NYSIR Certified NFPA-70 Certified UL 2200 Certified CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 16: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/16.jpg)
TEDOM CENTO L230, L320 & L520 Biogas Driven CHP Units*
Key Features & Benefits
Total efficiency of 87% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Plug and play”. All in one design allows for very easy connection of the CHP unit into the building’s heating system.
Very compact footprint, easy access design with removable covers and a flexible control panel placement allow for installation in very restricted areas.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Super-silent operation allows the unit to be located in noise sensitive areas.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Hotels
Condos, Co-ops & Apartments
Hospitals & Nursing Homes
Schools & Colleges
Housing Authorities
Swimming Pools
Health Clubs & Fitness Centers
Correctional Facilities
Industrial Facilities
Agricultural Operations
Laundries
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
* Natural Gas CENTO CHP units are also available
![Page 17: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/17.jpg)
Cento Series - Biogas Driven CHP Units
For get more information please visit www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
Specifications: 1
Series Cento L230 Cento L320 Cento L520
Engine G946 G9508 G9512
manufactured by Liebherr
Generator LSA 46.3 L10 LSA 47.2 S5 LSA 49.1 M6
manufactured by Leroy Somer
Electrical Output 235 kW 324 kW 520 kW
480 VAC, 3PH, 60 Hz
Maximum Heat Output 1,037,000 Btu/hr 1,567,000 Btu/hr 2,398,735 Btu/hr
Electrical Efficiency 33.7% (HHV)2 37.3% (LHV)3 31.7% (HHV)2 35.4% (LHV)3 33.6% (HHV)2 37.2% (LHV)3
Overall Efficiency 77.4% (HHV)2 85.6% (LHV)3 77.2 (HHV)2 85.5% (LHV)3 77.4 % (HHV)2 85.6 % (LHV)3
Fuel Input (HHV)2 2,147,000 Btu/h 3,125,000 Btu/h 4,768,410 Btu/hr
(LHV)3 2,375,220 Btu/hr 3,458,980 Btu/hr 5,275,320 Btu/hr
Required Gas Pressure 8-38” wc (container enclosure 20-40”)
Hot Water Flow 39.6 gpm 82.4 gpm 128.4 gpm
Minimum Entering Water Temperature 194° F
Maximum Leaving Water Temperature 104° F
Emissions
NOx 6.0 lb/MWh 6.0 lb/MWh 6.0 lb/MWh
CO 15 lb/MWh 15 lb/MWh 15 lb/MWh
VOC 2.0 lb/MWh 2.0 lb/MWh 2.0 lb/MWh
Enclosure Options Dimensions Max. Weight Operating
Temp. Range
Acoustic Levels* - dBa @ 1M
Standard / Ventilated / Exhaust Gas
Cento L230 - Open Module 189” L x 61” W x 89” H 12,038 lbs 50°-95° F 92 / n/a / 65
- Sound Enclosure 206” L x 61” W x 89” H 12,920 lbs 50°-95° F 75 / 85 / 65
- Container (@ 10M) 255.9” L x 141.7” W x 236.2” H 20,857 lbs -68°-95° F 63 / 63 / 63
Cento L320 - Open Module 197” L x 81” W x 106” H 16,789 lbs 50°-95° F 93 / n/a / 65
- Sound Enclosure 222.4” L x 81” W x 106” H 19,171 lbs 50°-95° F 76-71* / 86-76* / 65
- Container (@10M) 265.7” L x 204.7” W x 224.4” H 37,481 lbs -68°-95° F 75* / 75* / 75*
Cento L520 - Open Module 212.6” L x 92.5” W x 106.3” H 19,468 lbs. 50°-95° F 98 / n/a / 65
- Sound Enclosure 222.4” L x 100.4” W x 108.3” H 21,850 lbs. 50°-95° F 78-73* / 90-79*
- Container (@ 10M) 265.8” L x 204.7” W x 224.4” H 38,143 lbs. -68°-95° F 65 / 65 / 75*
* Lower acoustic levels (Silent and Super Silent) are not standard but may be ordered
NYSIR Certified NFPA-70 Certified UL 2200 Certified CSAC22.2 No 14 Certified, CSAC22.2 No 100 Certified Lloyd’s Register Quality Assurance - ISO9001 and ISO14001
![Page 18: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/18.jpg)
TEDOM QUANTO D800, D1200, D1600 & D2000
Natural Gas Driven CHP Units*
Key Features & Benefits
Total efficiency of 90% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Turnkey Installation”. A container solution ensures very easy installation at your site.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Industrial Facilities
Agricultural Operations
Municipal Heating Plants
Food Processing Plants
Heat & Electricity for Residential Areas
Large Medical Center Campuses
Large Educational Campuses
Housing Authorities
Correctional Facilities
Shopping Malls
Airports
* Biogas QUANTO CHP units are also available
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
![Page 19: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/19.jpg)
Quanto Series - Natural Gas Driven CHP Units
For get more information please visit www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 1020 Btu/scf (38 MJ/m3)
3 LHV of 912.5 Btu/scf (34 MJ/m3)
Specifications: 1
Series Quanto D800 Quanto D1200 Quanto D1600 Quanto D2000
Engine TCG 2016 V16 C TCG 2020 V12 TCG 2020 V16 TCG 2020 V20
Manufactured by MWM
Generator MJB 400 LC4 MJB 450 MB4 MJB 500 MC4 MJB 560 LA4
manufactured by Marelli
Electrical Output 800 kW 1200 kW 1560 kW 2000 kW
480 VAC, 3PH, 60 Hz
Maximum Heat Output 3,241,537 Btu/hr 4,476,734 Btu/hr 5,913,246 7,486,245 Btu/hr
Electrical Efficiency (HHV)2 37.2% 38.8% 38.4% 38.5%
(LHV)3 41.5% 43.4% 43.0% 43.4%
Overall Efficiency (HHV)2 81.3% 81.2% 81.1% 80.8%
(LHV)3 90.7% 90.8% 90.7% 90.6%
Fuel Input (HHV)2 7,347,480 Btu/hr 10,553,000 Btu/hr 13,847,480 Btu/hr 17,708,970 Btu/hr
(LHV)3 6,582,030 Btu/hr 9,441,404 Bth/hr 12,389,490 Btu/hr 15,736,810 Btu/hr
Required Gas Pressure 33-60” wc
Hot Water Flow 170 gpm 226.6 gpm 301.2 gpm 377.2 gpm
Minimum Entering Water Temp. 104° F
Maximum Leaving Water Temp. 194° F
Emissions
NOx 1.4 lb/MWh 1.4 lb/MWh 1.4 lb/MWh 1.4 lb/MWh
CO 0.85 lb/MWh 0.85 lb/MWh 0.85 lb/MWh 0.85 lb/MWh
VOC 1 lb/MWh 1 lb/MWh 1 lb/MWh 1 lb/MWh
Enclosure Options Dimensions Max. Weight* Operating
Temp. Range Acoustic Levels - dBa @ 10M
Quanto D800 - Container 531.5” L x 118.1” W x 315.0” H 64,424 lbs -68°-95° F 76
Quanto D1200 - Container 622.0” L x 236.2” W x 393.7” H 86,957 lbs -68°-95° F 78
Quanto D1600 - Container 582.0” L x 244.0” W x 393.7” H 95,835 lbs -68°-95° F 78
Quanto D2000 - Container 787.4” L x 216.5” W x 393.7” H 130,502 lbs -68°-95° F 78
* Approximate values
![Page 20: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/20.jpg)
TEDOM QUANTO D800, D1200, D1600 & D2000
Biogas Driven CHP Units*
Key Features & Benefits
Total efficiency of 90% (LHV) because you use the power and the heat. A remote and inefficient power plant can be only about 30% efficient.
“Turnkey Installation”. A container solution ensures very easy installation at your site.
Constant engine speed. The reliable industrial engine provides outstanding service life by running at a constant speed.
Low emissions meet even strict local emissions requirements.
Advanced engineering with industry leading technology .
Remote monitoring and fast maintenance and repair service from Tecogen’s local network of service technicians.
Industrial Facilities
Agricultural Operations
Municipal Heating Plants
Food Processing Plants
Heat & Electricity for Residential Areas
Large Medical Center Campuses
Large Educational Campuses
Housing Authorities
Correctional Facilities
Shopping Malls
Airports
* Natural Gas QUANTO CHP units are also available
Good sites for Combined Heat & Power have continuous demand for both electricity and hot water or heating.
![Page 21: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/21.jpg)
Quanto Series - Biogas Driven CHP Units
For get more information please visit www.TTcogen.com
or call 781.466.6400
TTcogen is a joint venture of TEDOM & Tecogen
45 First Avenue, Waltham, MA 02451
1 All specification are +/- 5% and are subject to change without notice.
2 HHV of 695 Btu/scf (25.9 MJ/Nm3)
3 LHV of 628 Btu/scf (23.4 MJ/Nm3)
Specifications: 1
Series Quanto D800 Quanto D1200 Cento D1600 Quanto D2000
Engine TCG 2016 V16 C TCG 2020 V12 TCG 2020 V16 TCG 2020 V20
Manufactured by MWM
Generator MJB 400 LC4 MJB 450 MB4 MJB 500 MC4 MJB 560 LA4
manufactured by Marelli
Electrical Output 800 kW 1200 kW 1560 kW 2000 kW
480 VAC, 3PH, 60 Hz
Maximum Heat Output 3,067,515 Btu/hr 4,432,375 Btu/hr 5,872,301 7,377,055 Btu/hr
Electrical Efficiency (HHV)2 37.7% 38.8% 38.2% 38.5%
(LHV)3 41.7% 43.4% 42.3% 43.4%
Overall Efficiency (HHV)2 80.1% 81.2% 80.4% 80.8%
(LHV)3 88.6% 90.8% 88.9% 90.6%
Fuel Input (HHV)2 7,235,159 Btu/hr 10,553,000 Btu/hr 13,926,550 Btu/hr 17,720,400 Btu/hr
(LHV)3 6,537,665 Btu/hr 9,441,404 Bth/hr 12,583,990 Btu/hr 15,736,810 Btu/hr
Required Gas Pressure 33-60” wc
Hot Water Flow 157 gpm 226.6 gpm 301.2 gpm 377.2 gpm
Minimum Entering Water Temp. 104° F
Maximum Leaving Water Temp. 194° F
Emissions
NOx 6 lb/MWh 6 lb/MWh 6 lb/MWh 6 lb/MWh
CO 15.1 lb/MWh 15.1 lb/MWh 15.1 lb/MWh 15.1 lb/MWh
VOC 3.2 lb/MWh 3.2 lb/MWh 3.2 lb/MWh 3.2 lb/MWh
Enclosure Options Dimensions Max. Weight* Operating Acoustic Levels - dBa @ 10M
Quanto D800 - Container 531.5” L x 118.1” W x 315.0” H 64,424 lbs -68°-95° F 76
Quanto D1200 - Container 622.0” L x 236.2” W x 393.7” H 86,957 lbs -68°-95° F 78
Quanto D1600 - Container 582.0” L x 244.0” W x 393.0” H 95,835 ibs -60°-95° F 78
Quanto D2000 - Container 787.4” L x 216.5” W x 393.7” H 130,502 lbs -68°-95° F 78
* Approximate values
![Page 22: Engine Driven Cogeneration...Small Natural Gas Driven CHP Units* Key Features & Benefits Total efficiency of more than 94% (LHV) because you use the power and the heat. A remote and](https://reader033.vdocument.in/reader033/viewer/2022060818/6097e2bdca2d5f20093fe7a3/html5/thumbnails/22.jpg)
TTcogen is a joint venture of TEDOM and Tecogen