Engine ro om total f lo o dingHig h pressure water mist
As one of the world’s few manufacturer, Danfoss Semco can offer protection of your engine room with a true high-pressure water mist without any additives. The advantage of the Sem-Safe system is that the very small quantities of water it uses are harmless to personnel and equipment.
Even electrical equipment is left undamaged, provided that protection is better than IP 22.
The Sem-Safe system is approved by all major classification societies IP 23. Consequently, it can replace Halon or can be used as a substitute for traditional CO2 systems.
S E m - S A f E WAt E r m I S t S y S t E m
H I g H A n D l O W P r E S S u r E C O 2 S y S t E m S
f O A m f I r E E x t I n g u I S H I n g S y S t E m
D r y C H E m I C A l P O W D E r f I r E E x t I n
g u I S H I n g S y S t E m
How water mist functions
Water mist is water that, at a high-pressure of 100 bar, creates a fine mist or fog. The fine water mist evaporates very quickly and the resulting steam starves the fire of oxygen, suppressing it. At the same time, the water evapo-ration creates the most efficient form of cooling. In this way, the fire is extinguished both by oxygen suppression and cooling, providing the advantages of both water and gas-based fire fighting.
High-pressure systems only create a high pressure during extinguishing. High pressure water mist will cool the areas around hot metal surfaces and the water mist evaporates before it reaches the hot metal. In this way, shock cooling and changes in metal structures can be avoided.
Danfoss Semco has been working with high-pressure water mist right from the start. This revolutionary new system is finding its way into more and more application areas, offering an efficient system that is environmentally friendly as well as harmless to users.
ApprovAl lEvEls And ExpEriEncE. We have already seen fires being almost instantly extinguished by the system after its release, thus saving repair costs and off-hire periods.
dA n F o s s sE M c o A / s
F i r E p roT E c T i on
s v E n dB orG v E J 2 5 3
dK - 5 2 6 0 odE n sE s .
p H on E : + 4 5 7 0 2 6 3 8 0 1
FAx : + 4 5 7 0 2 6 3 8 0 2
s em s afe @ d an fo s s - s em c o. c om
www.danfoss-semco.com
UCP
UCP
UCP
UCP
UCP
UCP
UCP
UCP
115 BargSet @
2321
22
M
20
2321
22
M
20
22
ITEMS SHOWN OUTSIDE THE FRAMES
WAT
ER S
UPP
LYPI
-210
0
ARE NOT SEMCO SUPPLY
S1
23
20
21
M
72
15
5
PT
4
RESERVOIR-TANK
3
6
H2O CYLINDER3 PCS.
SKID LIMIT
2941
37
4 PCS.N2 CYLINDER
31
PI-2
102
30
28
PI ZSO
25
19
38
XX
26
39
PS
39
PS
40
36 33
40
32
34
S
PUMP UNIT
FILTER UNIT
BACK-UP UNIT8
9
Typical arrangement of section valves in an engine room
Produced by Danfoss A/S ©, Danfoss Industri Service – G1 Advertising 06.09