enodeb performance monitoring reference (07)(pdf)-en
DESCRIPTION
LTE Performance Monitoring is very important for RF Optimizers.TRANSCRIPT
-
eNodeB
Performance Monitoring Reference
Issue 07
Date 2013-11-30
HUAWEI TECHNOLOGIES CO., LTD.
-
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
i
Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
ii
About This Document
Purpose
This document describes the information about eNodeB-related performance monitoring tasks,
including:
The descriptions of parameters for performance monitoring
The descriptions of monitor items
The value range of each monitor item
The formula used to calculate the value of each monitor item
Product Versions
The following table lists the product version related to this document.
Product Name Product Version
DBS3900 V100R008C00
The mapping single-mode base station version is:
eNodeB: V100R006C00
DBS3900 TDD
BTS3900
BTS3900A
BTS3900L
BTS3900AL
BTS3202E
BTS3203E LTE V100R006C00
In this document, BTS3203E refers to the BTS3203E LTE.
Intended Audience
This document is intended for:
System engineers
NOTE
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
iii
Site maintenance engineers
Change History
The following describes the changes in eNodeB Performance Monitoring Reference.
The document issues are as follows:
07 (2013-11-30)
06 (2013-10-30)
05 (2013-08-01)
04 (2013-07-22)
03 (2013-06-27)
02 (2013-05-30)
01 (2013-04-28)
Draft C (2013-04-10)
Draft B (2013-02-25)
Draft A (2013-02-08)
07 (2013-11-30)
This is the seventh official release.
Compared with Issue 06 (2013-10-30), this issue does not include any new information.
Compared with Issue 06 (2013-10-30), this issue includes the following new information.
Topic Change Description
2.6.4 Monitoring Results Updatad the descriptions of "Value Range"
and "Description" in Table 2-16 Results of
usage of RB monitoring.
2.17.3 Parameters Updated the condition inTable 2-45
Parameters for neighboring cells.
2.17.4 Monitoring Results Added the parameter "Local Cell ID" in
Table 2-46 Results of MLB monitoring.
3.1.4 Monitoring Results Added the descriptions of " UL CoMP User
Indication."
3.3.4 Monitoring Results Added note of the Description in parameters
of "NeighborCell RSRP[n]" and "NeighborCell RSRQ[n]."
3.4.4 Monitoring Results Updatad the descriptions of "Value Range"
and "Description" in CA Property.
3.6.4 Monitoring Results
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
iv
Topic Change Description
3.7.4 Monitoring Results Updatad the descriptions of "Value
Range" and "Description" in CA
Property.
Modified the Value Range of RLC
Buffer Length.
3.9.4 Monitoring Results Updatad the descriptions of "Value Range"
and "Description" in CA Property.
3.11.3 Parameters Added the parameter of Test Item.
3.11.4 Monitoring Results Updatad the descriptions of "Value Range"
and "Description" in CA Property.
3.12.4 Monitoring Results
3.13.4 Monitoring Results
3.14.3 Parameters
3.14.4 Monitoring Results
5.3.3 Parameters Updatad the Table 5-5Parameters for
transport port flux stat monitoring.
5.9.3 Parameters Updatad the descriptions of IPPM Flag.
Added the parameter of Destination IP
address.
5.9.4 Monitoring Results Updatad the Value Range of Test Type.
Compared with Issue 06 (2013-10-30), this issue deleted the following new information:
Deleted the Results of PVC monitoring in 5.4.4 Monitoring Results.
06 (2013-10-30)
This is the sixth official release.
Compared with Issue 05 (2013-08-01), this issue includes the following new information.
Topic Change Description
1.3.3 General Parameter Input Description Add the descriptions of General Parameter.
1.3 Precautions Add the descriptions of the Note.
3.7.4 Monitoring Results Updated the "Result of RLC data stream
monitoring."
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
v
Topic Change Description
3.8.4 Monitoring Results Updated the "Results of RLC throughput
monitoring."
3.12.4 Monitoring Results Updated the "Results of user downlink
property monitoring."
Compared with Issue 05 (2013-08-01), this issue does not include any changes.
No information in Issue 05 (2013-08-01) is deleted from this issu.
05 (2013-08-01)
This is the fifth official release.
Compared with Issue 04 (2013-07-22), this issue does not include any new information.
Compared with Issue 04 (2013-07-22), this issue includes the following changes.
Topic Change Description
5.3 Transport Port Flux Stat Monitoring Modified descriptions of Usage Scenario.
No information in Issue 04 (2013-07-22) is deleted from this issu
04 (2013-07-22)
This is the fourth official release.
Compared with Issue 03 (2013-06-27), this issue includes the following new information.
Topic Change Description
Whole document Added descriptions of BTS3203Es.
Compared with Issue 03 (2013-06-27), this issue includes the following changes.
Topic Change Description
3 User Performance Monitoring Modified the value range of Physical Cell
Identifier.
2.14 HARQ Statistic Monitoring Modified the description of the Code[m]
DTX Num.
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
vi
Topic Change Description
0
UL SRS RSRP
Table 1-1 Results of UL SRS RSRP
Parameter Unit Value Range Description Formula
CA Property N/A N/A Carrier aggregation property of a user.
The result contains
Non CA, CA PCell
and CA SCell.
N/A
Physical Cell
Identifier
N/A 0~503 Physical cell ID of a
serving cell.
N/A
ServCell
RSRP
0.01dBm -15000 ~ -3000 RSRP of a serving
cell.
N/A
NeighborCel
l PCI[n] N/A 0~503 Physical cell ID of the
nth neighboring cell.
n is an integer from 1
to 8.
This field specifies the
sequence for reporting
the measurement
reports of neighboring
cells. A maximum of
eight neighboring
cells are dynamically
displayed.
N/A
NeighborCel
l RSRP
0.01dBm -15000 ~ -3000 Physical cell ID of the
nth neighboring cell.
n is an integer from 1 to 8.
This field specifies the sequence for reporting the measurement reports of neighboring cells. A maximum of eight neighboring cells are dynamically displayed.
Scheduling Monitoring
Modified the description of the Byte Length
of LCG BS[n] in section 3.1.4 Monitoring
Results.
NOTE
NOTE
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
vii
No information in Issue 03 (2013-06-27) is deleted from this issue.
03 (2013-06-27)
This is the third official release.
Compared with Issue 02 (2013-05-30), this issue does not include any new information.
Compared with Issue 02 (2013-05-30), this issue includes the following changes.
Topic Change Description
3.11.4 Monitoring Results Modified the description in section "PDSCH
Maximum Number of Transmissions".
5.6.3 Parameters Modified the name of "PPPoELink No".
No information in Issue 02 (2013-05-30) is deleted from this issue.
02 (2013-05-30)
This is the second official release.
Compared with Issue 01 (2013-04-28), this issue does not include any new information.
Compared with Issue 01 (2013-04-28), this issue includes the following changes.
Topic Change Description
2.2 Satisfaction of Service Monitoring Modified the description in section 2.2.1
"Usage Scenario."
Modified the description of parameters CN
Operator UL QCI[n] Satisfaction rate of Service and CN Operator DL QCI[n]
Satisfaction rate of Service in section
"Monitoring Results."
No information in Issue 01 (2013-04-28) is deleted from this issue.
01 (2013-04-28)
This is the first official release.
Compared with draft C (2013-04-10), this issue does not include any new information.
Compared with draft C (2013-04-10), this issue includes the following changes.
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
viii
Topic Change Description
4.3 RRU/RFU/BRU Output Power
Monitoring
4.8 Rx Frequency Scanning
4.9 DTF Test
5.5 UDP Test Monitoring
6.1 Sector Performance Monitoring
Modified monitoring results.
The following information in draft C (2013-04-10) is deleted from this issue:
LTE IP Link Monitoring
LTE IP Path Performance Monitoring
LTE SCTP Performance Monitoring
LTE Resource Group Monitoring
Draft C (2013-04-10)
This is the release of Draft C.
Compared with draft B (2013-02-25), this issue does not include any new information.
Compared with draft B (2013-02-25), this issue includes the following changes.
Topic Change Description
2.5 User Statistics Monitoring
2.16 DRB Statistics Monitoring
3.3 DL RSRP/RSRQ Monitoring
4.3 RRU/RFU/BRU Output Power Monitoring
4.4 Board Temperature Monitoring
4.7 RRU/RFU Output Power Monitoring
Modified the monitoring results of the
monitoring tasks in these sections.
No information in draft B (2013-02-25) is deleted from this issue.
Draft B (2013-02-25)
This is the release of Draft B.
Compared with draft A (2013-02-08), this issue does not include any new information.
Compared with draft A (2013-02-08), this issue includes the following changes.
Topic Change Description
3.2 VQI Monitoring Modified the description of VQI Monitoring.
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
ix
Topic Change Description
3.6 Quality of Channel Monitoring Modified the description of
Quality of Channel Monitoring.
No information in issue draft A (2013-02-08) is deleted from this issue.
Draft A (2013-02-08)
This is the release of Draft A.
Compared with issue 02 (2012-11-30) of V100R005C01, this issue includes the following
new information.
Topic Change Description
2.1 UL CoMP (Cell) Monitoring Added the descriptions on UL CoMP (Cell)
Monitoring.
3.1 UL CoMP (User) Monitoring Added the descriptions on UL CoMP (User)
Monitoring.
2.17 MLB Monitoring Added new monitoring items.
3.2 VQI Monitoring Added new monitoring items.
3.16 Cell Combination Monitoring Added new monitoring items.
4.4 Board Temperature Monitoring Added new monitoring items.
4.7 RRU/RFU Output Power Monitoring Added new monitoring items.
4.8 Rx Frequency Scanning Added new monitoring items.
4.9 DTF Test Added new monitoring items.
4.10 FFT Frequency Scan Added new monitoring items.
4.11 AAS Added new monitoring items.
4.12 Frequency Scanning Intermodulation
Interference Detection Monitoring
Added new monitoring items.
5.3 Transport Port Flux Stat Monitoring Added new monitoring items.
5.4 Transport Link Flux Stat Monitoring Added new monitoring items.
5.7 IPSec Performance Monitoring Added new monitoring items.
5.8 Transport OAM Monitoring Added new monitoring items.
5.9 Transport Auto Setup User Plane
Monitoring
Added new monitoring items.
Compared with issue 02 (2012-11-30) of V100R005C01, this issue includes the following
changes:
-
eNodeB
Performance Monitoring Reference About This Document
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
x
Topic Change Description
2.9 RSSI Statistic Monitoring
2.10 Interference Detection Monitoring
2.11 TDD Interference Detection
Monitoring
Modified the descriptions on the results of
parameters and monitoring results.
6.1 Sector Performance Monitoring Modified the Local Sector ID parameter to the
Sector Device ID parameter.
Added the value range for the Sector Device ID
parameter.
The following information in issue 02 (2012-11-30) of V100R005C01 is deleted from this
issue:
Board Temperature Monitoring
Transport Performance Monitoring
Spectrum Detection
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xi
Contents
About This Document .................................................................................................................... ii
1 Introduction.................................................................................................................................... 1
1.1 Overview .......................................................................................................................................................... 1
1.2 Performance Monitoring Types ........................................................................................................................ 1
1.3 Precautions ....................................................................................................................................................... 3
1.3.1 Precautions for Monitoring on 3900 Series Base Stations ...................................................................... 3
1.3.2 Precautions for Monitoring on BTS3202Es and BTS3203Es ................................................................. 4
1.3.3 General Parameter Input Description ...................................................................................................... 5
2 Cell Performance Monitoring ..................................................................................................... 7
2.1 UL CoMP (Cell) Monitoring ............................................................................................................................ 7
2.1.1 Usage Scenario ........................................................................................................................................ 7
2.1.2 Impact on Services .................................................................................................................................. 7
2.1.3 Parameters ............................................................................................................................................... 7
2.1.4 Monitoring Results .................................................................................................................................. 8
2.2 Satisfaction of Service Monitoring ................................................................................................................... 8
2.2.1 Usage Scenario ........................................................................................................................................ 8
2.2.2 Service Impact ........................................................................................................................................ 8
2.2.3 Parameters ............................................................................................................................................... 9
2.2.4 Monitoring Results .................................................................................................................................. 9
2.3 General Throughput Monitoring .................................................................................................................... 11
2.3.1 Usage Scenario ...................................................................................................................................... 11
2.3.2 Service Impact ...................................................................................................................................... 11
2.3.3 Parameters ............................................................................................................................................. 11
2.3.4 Monitoring Results ................................................................................................................................ 11
2.4 Service Statistics Monitoring ......................................................................................................................... 14
2.4.1 Usage Scenario ...................................................................................................................................... 14
2.4.2 Service Impact ...................................................................................................................................... 14
2.4.3 Parameters ............................................................................................................................................. 15
2.4.4 Monitoring Results ................................................................................................................................ 15
2.5 User Statistics Monitoring .............................................................................................................................. 16
2.5.1 Usage Scenario ...................................................................................................................................... 16
2.5.2 Service Impact ...................................................................................................................................... 16
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xii
2.5.3 Parameters ............................................................................................................................................. 16
2.5.4 Monitoring Results ................................................................................................................................ 16
2.6 Usage of RB Monitoring ................................................................................................................................ 19
2.6.1 Usage Scenario ...................................................................................................................................... 19
2.6.2 Service Impact ...................................................................................................................................... 19
2.6.3 Parameters ............................................................................................................................................. 19
2.6.4 Monitoring Results ................................................................................................................................ 19
2.7 ICIC (Cell) Monitoring .................................................................................................................................. 21
2.7.1 Usage Scenario ...................................................................................................................................... 21
2.7.2 Service Impact ...................................................................................................................................... 21
2.7.3 Parameters ............................................................................................................................................. 21
2.7.4 Monitoring Results ................................................................................................................................ 22
2.8 Multi-User MIMO Monitoring ....................................................................................................................... 23
2.8.1 Usage Scenario ...................................................................................................................................... 23
2.8.2 Service Impact ...................................................................................................................................... 24
2.8.3 Parameters ............................................................................................................................................. 24
2.8.4 Monitoring Results ................................................................................................................................ 24
2.9 RSSI Statistic Monitoring .............................................................................................................................. 24
2.9.1 Usage Scenario ...................................................................................................................................... 24
2.9.2 Service Impact ...................................................................................................................................... 24
2.9.3 Parameters ............................................................................................................................................. 24
2.9.4 Monitoring Results ................................................................................................................................ 25
2.10 Interference Detection Monitoring ............................................................................................................... 28
2.10.1 Usage Scenario .................................................................................................................................... 28
2.10.2 Service Impact .................................................................................................................................... 28
2.10.3 Parameters ........................................................................................................................................... 28
2.10.4 Monitoring Results .............................................................................................................................. 29
2.11 TDD Interference Detection Monitoring ...................................................................................................... 31
2.11.1 Usage Scenario .................................................................................................................................... 31
2.11.2 Impact on Services .............................................................................................................................. 31
2.11.3 Parameters ........................................................................................................................................... 31
2.11.4 Monitoring Results .............................................................................................................................. 32
2.12 Multi-User BF (Cell) Monitoring ................................................................................................................. 33
2.12.1 Usage Scenario .................................................................................................................................... 33
2.12.2 Impact on Services .............................................................................................................................. 33
2.12.3 Parameters ........................................................................................................................................... 33
2.12.4 Monitoring Results .............................................................................................................................. 34
2.13 Scheduled Users Statistic Monitoring .......................................................................................................... 35
2.13.1 Usage Scenario .................................................................................................................................... 35
2.13.2 Service Impact .................................................................................................................................... 35
2.13.3 Parameters ........................................................................................................................................... 35
2.13.4 Monitoring Results .............................................................................................................................. 36
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xiii
2.14 HARQ Statistic Monitoring.......................................................................................................................... 36
2.14.1 Usage Scenario .................................................................................................................................... 36
2.14.2 Service Impact .................................................................................................................................... 36
2.14.3 Parameters ........................................................................................................................................... 37
2.14.4 Monitoring Results .............................................................................................................................. 37
2.15 DCI Statistic Monitoring .............................................................................................................................. 40
2.15.1 Usage Scenario .................................................................................................................................... 40
2.15.2 Service Impact .................................................................................................................................... 40
2.15.3 Parameters ........................................................................................................................................... 40
2.15.4 Monitoring Results .............................................................................................................................. 41
2.16 DRB Statistics Monitoring ........................................................................................................................... 42
2.16.1 Usage Scenario .................................................................................................................................... 42
2.16.2 Service Impact .................................................................................................................................... 42
2.16.3 Parameters ........................................................................................................................................... 42
2.16.4 Monitoring Results .............................................................................................................................. 42
2.17 MLB Monitoring .......................................................................................................................................... 45
2.17.1 Usage Scenario .................................................................................................................................... 45
2.17.2 Service Impact .................................................................................................................................... 45
2.17.3 Parameters ........................................................................................................................................... 45
2.17.4 Monitoring Results .............................................................................................................................. 46
3 User Performance Monitoring .................................................................................................. 60
3.1 UL CoMP (User) Monitoring ......................................................................................................................... 60
3.1.1 Usage Scenario ...................................................................................................................................... 60
3.1.2 Service Impact ...................................................................................................................................... 60
3.1.3 Parameters ............................................................................................................................................. 60
3.1.4 Monitoring Results ................................................................................................................................ 61
3.2 VQI Monitoring.............................................................................................................................................. 61
3.2.1 Usage Scenario ...................................................................................................................................... 61
3.2.2 Service Impact ...................................................................................................................................... 61
3.2.3 Parameters ............................................................................................................................................. 61
3.2.4 Monitoring Results ................................................................................................................................ 62
3.3 DL RSRP/RSRQ Monitoring ......................................................................................................................... 63
3.3.1 Usage Scenario ...................................................................................................................................... 63
3.3.2 Service Impact ...................................................................................................................................... 63
3.3.3 Parameters ............................................................................................................................................. 63
3.3.4 Monitoring Results ................................................................................................................................ 64
3.4 BLER Monitoring .......................................................................................................................................... 64
3.4.1 Usage Scenario ...................................................................................................................................... 64
3.4.2 Service Impact ...................................................................................................................................... 64
3.4.3 Parameters ............................................................................................................................................. 65
3.4.4 Monitoring Results ................................................................................................................................ 65
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xiv
3.5 Power Headroom Monitoring ......................................................................................................................... 68
3.5.1 Usage Scenario ...................................................................................................................................... 68
3.5.2 Service Impact ...................................................................................................................................... 68
3.5.3 Parameters ............................................................................................................................................. 68
3.5.4 Monitoring Results ................................................................................................................................ 68
3.6 Quality of Channel Monitoring ...................................................................................................................... 69
3.6.1 Usage Scenario ...................................................................................................................................... 69
3.6.2 Service Impact ...................................................................................................................................... 69
3.6.3 Parameters ............................................................................................................................................. 69
3.6.4 Monitoring Results ................................................................................................................................ 70
3.7 Scheduling Monitoring ................................................................................................................................... 71
3.7.1 Usage Scenario ...................................................................................................................................... 72
3.7.2 Service Impact ...................................................................................................................................... 72
3.7.3 Parameters ............................................................................................................................................. 72
3.7.4 Monitoring Results ................................................................................................................................ 74
3.8 RLC Data Stream Monitoring ........................................................................................................................ 76
3.8.1 Usage Scenario ...................................................................................................................................... 76
3.8.2 Service Impact ...................................................................................................................................... 76
3.8.3 Parameters ............................................................................................................................................. 76
3.8.4 Monitoring Results ................................................................................................................................ 76
3.9 Throughput Monitoring .................................................................................................................................. 77
3.9.1 Usage Scenario ...................................................................................................................................... 77
3.9.2 Service Impact ...................................................................................................................................... 77
3.9.3 Parameters ............................................................................................................................................. 77
3.9.4 Monitoring Results ................................................................................................................................ 78
3.10 AQM Monitoring ......................................................................................................................................... 79
3.10.1 Usage Scenario .................................................................................................................................... 79
3.10.2 Service Impact .................................................................................................................................... 79
3.10.3 Parameters ........................................................................................................................................... 79
3.10.4 Monitoring Results .............................................................................................................................. 80
3.11 UL Power Control Monitoring ..................................................................................................................... 80
3.11.1 Usage Scenario .................................................................................................................................... 80
3.11.2 Service Impact ..................................................................................................................................... 80
3.11.3 Parameters ........................................................................................................................................... 81
3.11.4 Monitoring Results .............................................................................................................................. 81
3.12 DL Power Control Monitoring ..................................................................................................................... 82
3.12.1 Usage Scenario .................................................................................................................................... 82
3.12.2 Service Impact .................................................................................................................................... 82
3.12.3 Parameters ........................................................................................................................................... 82
3.12.4 Monitoring Results .............................................................................................................................. 83
3.13 ICIC (User) Monitoring ............................................................................................................................... 84
3.13.1 Usage Scenario .................................................................................................................................... 84
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xv
3.13.2 Service Impact .................................................................................................................................... 84
3.13.3 Parameters ........................................................................................................................................... 84
3.13.4 Monitoring Results .............................................................................................................................. 85
3.14 MCS Count Monitoring ............................................................................................................................... 86
3.14.1 Usage Scenario .................................................................................................................................... 86
3.14.2 Service Impact .................................................................................................................................... 87
3.14.3 Parameters ........................................................................................................................................... 87
3.14.4 Monitoring Results .............................................................................................................................. 87
3.15 Multi-User BF (User) Monitoring ................................................................................................................ 89
3.15.1 Usage Scenario .................................................................................................................................... 89
3.15.2 Impact on Services .............................................................................................................................. 89
3.15.3 Parameters ........................................................................................................................................... 89
3.15.4 Monitoring Results .............................................................................................................................. 89
3.16 SFN Detection Monitoring ........................................................................................................................... 90
3.16.1 Usage Scenario .................................................................................................................................... 90
3.16.2 Impact on Services .............................................................................................................................. 90
3.16.3 Parameters ........................................................................................................................................... 90
3.16.4 Monitoring Results .............................................................................................................................. 91
3.17 Cell Combination Monitoring ...................................................................................................................... 92
3.17.1 Usage Scenario .................................................................................................................................... 92
3.17.2 Impact on Services .............................................................................................................................. 92
3.17.3 Parameters ........................................................................................................................................... 92
3.17.4 Monitoring Results .............................................................................................................................. 93
4 Device Monitoring ...................................................................................................................... 95
4.1 CPRI BER Monitoring ................................................................................................................................... 95
4.1.1 Usage Scenario ...................................................................................................................................... 95
4.1.2 Service Impact ...................................................................................................................................... 95
4.1.3 Parameters ............................................................................................................................................. 95
4.1.4 Monitoring Results ................................................................................................................................ 96
4.2 CPU Usage Monitoring .................................................................................................................................. 96
4.2.1 Usage Scenario ...................................................................................................................................... 96
4.2.2 Service Impact ...................................................................................................................................... 96
4.2.3 Parameters ............................................................................................................................................. 97
4.2.4 Monitoring Results ................................................................................................................................ 97
4.3 RRU/RFU/BRU Output Power Monitoring ................................................................................................... 97
4.3.1 Usage Scenario ...................................................................................................................................... 97
4.3.2 Service Impact ...................................................................................................................................... 97
4.3.3 Parameters ............................................................................................................................................. 98
4.3.4 Monitoring Results ................................................................................................................................ 98
4.4 Board Temperature Monitoring ...................................................................................................................... 99
4.4.1 Usage Scenario ...................................................................................................................................... 99
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xvi
4.4.2 Service Impact ...................................................................................................................................... 99
4.4.3 Parameters ............................................................................................................................................. 99
4.4.4 Monitoring Results .............................................................................................................................. 100
4.5 Clock Quality Test Monitoring ..................................................................................................................... 100
4.5.1 Usage Scenario .................................................................................................................................... 100
4.5.2 Service Impact .................................................................................................................................... 100
4.5.3 Parameters ........................................................................................................................................... 101
4.5.4 Monitoring Results .............................................................................................................................. 101
4.6 IP Clock Data Collection Monitoring ........................................................................................................... 102
4.6.1 Usage Scenario .................................................................................................................................... 102
4.6.2 Service Impact .................................................................................................................................... 102
4.6.3 Parameters ........................................................................................................................................... 102
4.6.4 Monitoring Results .............................................................................................................................. 103
4.7 RRU/RFU Output Power Monitoring .......................................................................................................... 103
4.7.1 Usage Scenario .................................................................................................................................... 103
4.7.2 Service Impact .................................................................................................................................... 103
4.7.3 Parameters ........................................................................................................................................... 103
4.7.4 Monitoring Results .............................................................................................................................. 104
4.8 Rx Frequency Scanning ............................................................................................................................... 105
4.8.1 Usage Scenario .................................................................................................................................... 105
4.8.2 Service Impact .................................................................................................................................... 105
4.8.3 Parameters ........................................................................................................................................... 105
4.8.4 Monitoring Results .............................................................................................................................. 106
4.9 DTF Test ....................................................................................................................................................... 106
4.9.1 Usage Scenario .................................................................................................................................... 106
4.9.2 Service Impact .................................................................................................................................... 107
4.9.3 Parameters ........................................................................................................................................... 107
4.9.4 Monitoring Results .............................................................................................................................. 107
4.10 FFT Frequency Scan .................................................................................................................................. 108
4.10.1 Usage Scenario .................................................................................................................................. 108
4.10.2 Service Impact .................................................................................................................................. 108
4.10.3 Parameters ......................................................................................................................................... 108
4.10.4 Monitoring Results ............................................................................................................................ 109
4.11 AAS ............................................................................................................................................................ 110
4.11.1 Usage Scenario .................................................................................................................................. 110
4.11.2 Service Impact ................................................................................................................................... 110
4.11.3 Parameters ......................................................................................................................................... 110
4.11.4 Monitoring Results ............................................................................................................................ 111
4.12 Frequency Scanning Intermodulation Interference Detection Monitoring ................................................. 111
4.12.1 Usage Scenario .................................................................................................................................. 111
4.12.2 Service Impact .................................................................................................................................. 111
4.12.3 Parameters ......................................................................................................................................... 111
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xvii
4.12.4 Monitoring Results ............................................................................................................................ 112
5 Transport Performance Monitoring ...................................................................................... 113
5.1 Local Pass-By Traffic Monitoring ................................................................................................................ 113
5.1.1 Usage Scenario .................................................................................................................................... 113
5.1.2 Service Impact .................................................................................................................................... 113
5.1.3 Parameters ........................................................................................................................................... 113
5.1.4 Monitoring Results .............................................................................................................................. 113
5.2 IP Performance Monitoring .......................................................................................................................... 114
5.2.1 Usage Scenario .................................................................................................................................... 114
5.2.2 Service Impact .................................................................................................................................... 114
5.2.3 Parameters ........................................................................................................................................... 114
5.2.4 Monitoring Results .............................................................................................................................. 115
5.3 Transport Port Flux Stat Monitoring ............................................................................................................ 115
5.3.1 Usage Scenario .................................................................................................................................... 115
5.3.2 Service Impact .................................................................................................................................... 115
5.3.3 Parameters ........................................................................................................................................... 115
5.3.4 Monitoring Results .............................................................................................................................. 117
5.4 Transport Link Flux Stat Monitoring ........................................................................................................... 123
5.4.1 Usage Scenario .................................................................................................................................... 123
5.4.2 Service Impact .................................................................................................................................... 123
5.4.3 Parameters ........................................................................................................................................... 123
5.4.4 Monitoring Results .............................................................................................................................. 125
5.5 UDP Test Monitoring ................................................................................................................................... 128
5.5.1 Usage Scenario .................................................................................................................................... 128
5.5.2 Service Impact .................................................................................................................................... 128
5.5.3 Parameters ........................................................................................................................................... 128
5.5.4 Monitoring Results .............................................................................................................................. 129
5.6 PPPoE Monitoring ....................................................................................................................................... 130
5.6.1 Usage Scenario .................................................................................................................................... 130
5.6.2 Service Impact .................................................................................................................................... 130
5.6.3 Parameters ........................................................................................................................................... 130
5.6.4 Monitoring Results .............................................................................................................................. 130
5.7 IPSec Performance Monitoring .................................................................................................................... 131
5.7.1 Usage Scenario .................................................................................................................................... 131
5.7.2 Service Impact .................................................................................................................................... 131
5.7.3 Parameters ........................................................................................................................................... 132
5.7.4 Monitoring Results .............................................................................................................................. 132
5.8 Transport OAM Monitoring ......................................................................................................................... 132
5.8.1 Usage Scenario .................................................................................................................................... 132
5.8.2 Service Impact .................................................................................................................................... 133
5.8.3 Parameters ........................................................................................................................................... 133
-
eNodeB
Performance Monitoring Reference Contents
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
xviii
5.8.4 Monitoring Results .............................................................................................................................. 133
5.9 Transport Auto Setup User Plane Monitoring .............................................................................................. 134
5.9.1 Usage Scenario .................................................................................................................................... 134
5.9.2 Service Impact .................................................................................................................................... 134
5.9.3 Parameters ........................................................................................................................................... 135
5.9.4 Monitoring Results .............................................................................................................................. 135
6 RRU/RFU Performance Monitoring ...................................................................................... 138
6.1 Sector Performance Monitoring ................................................................................................................... 138
6.1.1 Usage Scenario .................................................................................................................................... 138
6.1.2 Service Impact .................................................................................................................................... 138
6.1.3 Parameters ........................................................................................................................................... 138
6.1.4 Monitoring Results .............................................................................................................................. 139
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1
1 Introduction 1.1 Overview
Performance monitoring is used to monitor the equipment running status and service status of
eNodeBs by using iManager M2000 Mobile Element Management System (referred to as
M2000) or the local maintenance terminal (LMT). Monitoring results are displayed in tables
or charts. In this way, equipment can be maintained and faults can be rectified by analyzing
the exceptions shown in monitoring results.
1.2 Performance Monitoring Types
Table 1-1 Performance monitoring types
Type Task Platform
Cell Performance
Monitoring
UL CoMP (Cell) Monitoring M2000
Satisfaction of Service Monitoring M2000
General Throughput Monitoring M2000&LMT
Service Statistics Monitoring M2000
User Statistics Monitoring M2000&LMT
Usage of RB Monitoring M2000
ICIC (Cell) Monitoring M2000
Multi-User MIMO Monitoring M2000
RSSI Statistic Monitoring M2000
Interference Detection Monitoring M2000&LMT
TDD Interference Detection Monitoring M2000
Multi-User BF (Cell) Monitoring M2000
Scheduled Users Statistic Monitoring M2000
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
2
Type Task Platform
HARQ Statistic Monitoring M2000
DCI Statistic Monitoring M2000
DRB Statistics Monitoring M2000
MLB Monitoring M2000
User Performance
Monitoring UL CoMP (User) Monitoring M2000
VQI Monitoring M2000
DL RSRP/RSRQ Monitoring M2000
BLER Monitoring M2000
Power Headroom Monitoring M2000
Quality of Channel Monitoring M2000
Scheduling Monitoring M2000
RLC Data Stream Monitoring M2000
Throughput Monitoring M2000
AQM Monitoring M2000
UL Power Control Monitoring M2000
DL Power Control Monitoring M2000
ICIC (User) Monitoring M2000
MCS Count Monitoring M2000
Multi-User BF (User) Monitoring M2000
SFN Detection Monitoring M2000
Cell Combination Monitoring M2000
Device Monitoring CPRI BER Monitoring M2000
CPU Usage Monitoring M2000&LMT
RRU/RFU/BRU Output Power
Monitoring
M2000
Board Temperature Monitoring M2000&LMT
Clock Quality Test Monitoring M2000&LMT
IP Clock Data Collection Monitoring M2000&LMT
RRU/RFU Output Power Monitoring LMT
Rx Frequency Scanning LMT
DTF Test LMT
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3
Type Task Platform
FFT Frequency Scan LMT
AAS LMT
Frequency Scanning Intermodulation
Interference Detection
LMT
Transport Performance
Monitoring
Local Pass-By Traffic Monitoring M2000&LMT
IP Performance Monitoring M2000&LMT
Transport Port Flux Stat Monitoring M2000&LMT
Transport Link Flux Stat Monitoring M2000&LMT
UDP Test Monitoring M2000
PPPoE Monitoring M2000&LMT
IPSec Performance Monitoring M2000&LMT
Transport OAM Monitoring LMT
Transport Auto Setup User Plane
Monitoring
LMT
RRU/RFU Performance
Monitoring
Sector Performance Monitoring LMT
1.3 Precautions
This section describes the precautions for monitoring on 3900 series base stations and
BTS3202Es,and BTS3203Es.
This issue do not support the following monitoring tasks:
LTE IP Link Monitoring
LTE IP Path Performance Monitoring
LTE SCTP Performance Monitoring
LTE Resource Group Monitoring
1.3.1 Precautions for Monitoring on 3900 Series Base Stations
3900 series base stations do not support the PPPoE Monitoring task. The PPPoE Monitoring
task is available only on BTS3202Es and BTS3203Es.
A carrier aggregation (CA) UE is able to access multiple cells simultaneously and report the
monitoring results of each cell at the same time. However, if a CA UE whose secondary
serving cell (SCell) is not configured or not activated, monitoring results in the SCell will not
NOTE
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4
be reported. If a monitoring item does not involve the CA feature, actual monitoring result of
the monitoring item is reported.
1.3.2 Precautions for Monitoring on BTS3202Es and BTS3203Es
Take the following precautions for monitoring on BTS3202Es and BTS3203Es:
The values of Cabinet No., Subrack No., and Slot No. must be 0.
The value of Local Cell ID must be 0.
BTS3202Es and BTS3203Es do not support the following monitoring tasks:
UL CoMP (Cell) Monitoring
CPRI BER Monitoring
TDD Interference Detection Monitoring
Multi-User BF (Cell) Monitoring
UL CoMP (User) Monitoring
Multi-User BF (User) Monitoring
SFN User Detection
RRU/RFU Output Power Monitoring
DTF Test
AAS
Frequency Scanning Intermodulation Interference Detection Monitoring
Transport OAM Monitoring
BTS3202Es support the following monitoring tasks:
Rx Frequency Scanning
FFT Frequency Scan
BTS3202Es do not support PPP Performance monitoring and MP Performance
monitoring in the Transport Port Flux Stat Monitoring task.
BTS3202Es do not support the CA Property monitoring item in the following
monitoring tasks:
BLER Monitoring
Power Headroom Monitoring
Quality of Channel Monitoring
Scheduling Monitoring
Throughput Monitoring
UL Power Control Monitoring
DL Power Control Monitoring
ICIC (User) Monitoring
MCS Count Monitoring
The monitoring results of this monitoring item in these monitoring tasks are Non CA.
In Transport Port Flux Stat Monitoring and Transport Link Flux Stat Monitoring tasks,
Subboard Type must be BASE_BOARD.
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
5
1.3.3 General Parameter Input Description
UEIDs are used to trace UE-level performance tests. UEIDs can be set to S-Temporary
Mobile Subscriber Identity (STMSI), Random Value, and Trace Reference No.
The following describes how to obtain and use the three types of UEIDs:
STMSI and Random Value
The ue-Identity IE in the RRC Connection Request message contains the MMEc and
m-TMSI fields. Therefore, you can obtain the MMEc and m-TMSI in hexadecimal
format from the ue-Identity IE. Enter the MMEc and m-TMSI in decimal format on the
trace interface.
The RRC Connection Request message may carry a Random Value in hexadecimal
format. Enter the Random Value in hexadecimal format on the trace interface.
The STMSI in decimal format and Random Value in hexadecimal format can also be
queried by running DSP ALLUEBASICINFO.
If the EPC does not support IMSI-based single UE tracing on the entire network, use the STMSI and
Random Value to collect data for single UE tracing and monitoring.
A maximum of 30 NEs of the same version can be selected when creating the tracing and monitoring
tasks based on the STMSI and Random Value. If the specified UE can be successfully handed over
among multiple selected NEs over the X2 interface, the UE data can be continuously collected in the
tracing and monitoring task.
If the eNodeB is not a selected NE for this tracing task, the M2000 cannot continue collecting data, even when the UE is handed over to the original eNodeB.
Due to the timing sequence problem, however, some data may fail to be recorded when the UE is
handed over to the target NE.
Trace Reference No.
For details about the Trace Reference No., see Trace ID in 3GPP TS 32.422. The value
range is 016777215 (3 bytes).
Use a Trace Reference No. in the following conditions:
The EPC of a vendor must support single UE tracing on the entire network based on the
IMSI (complying with 3GPP TS 32.422), and the tracing task has been initiated.
For example, the EPC of Huawei has initiated LTE/EPC End-to-End User Trace.
The Trace Reference No. on the LTE side can be obtained from:
For the Huawei EPC, obtain the TraceID that is automatically displayed on the interface
when LTE/EPC End-to-End User Trace is created.
Obtain the Trace Reference No. from the Trace Activation IE from the S1 interface
messages (INITIAL CONTEXT SETUP REQUEST, HANDOVER REQUEST, TRACE START) and the X2 interface message (HANDOVER REQUEST).
Click displayed at the end of the User Trace ID of each tracing and monitoring task,
the M2000 will provide the existing Trace Reference No. on the live network.
The M2000 lists the Trace Reference No. of the first 200 tracing tasks in the recent two days.
If the EPC supports IMSI-based single UE tracing on the entire network, use the Trace Reference No. to
collect data for single UE tracing and monitoring.
A maximum of 30 NEs can be selected when creating the tracing and monitoring tasks based on the
Trace Reference No. The UE data can be continuously collected as long as the UE is served by the
selected NEs.
-
eNodeB
Performance Monitoring Reference 1 Introduction
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
6
If the eNodeB is not a selected NE for this tracing task, the M2000 cannot continue collecting data.
However, the M2000 can collect the data again when the UE is handed over to the original eNodeB.
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
7
2 Cell Performance Monitoring 2.1 UL CoMP (Cell) Monitoring
2.1.1 Usage Scenario
This task is used to monitor the number of cell-level UEs using uplink (UL) coordinated
multi-point (CoMP). This counter measures the UL CoMP Users Num of Scenario 1, UL
CoMP Users Num of Scenario 2, and UL CoMP Users Num of mixed Scenario. This
monitoring item is used to initially determine the usage of the UL CoMP function in a cell.
2.1.2 Impact on Services
None.
2.1.3 Parameters
Table 2-1 Parameters for UL CoMP (Cell) monitoring
Parameter Description
Local Cell ID Local cell ID of the cell performing cell-level UL CoMP
monitoring.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 1000, 2000.
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
8
2.1.4 Monitoring Results
Table 2-2 Results of UL CoMP (Cell) monitoring
Parameter Unit Value Range
Description Formula
UL CoMP
Users Num of
Scenario 1
Number 0 to 1000 The eNodeB reports the number
of UEs using the UL CoMP in
scenario 1 to the M2000 at the
end of each monitoring period.
UL CoMP Users of Scenario 1:
UEs located at the cell edge
using the UL CoMP function.
N/A
UL CoMP
Users Num of
Scenario 2
Number 0 to 1000 The eNodeB reports the number
of UEs using the UL CoMP in
scenario 2 to the M2000 at the
end of each monitoring period.
UL CoMP Users of Scenario 2:
UEs that are interfered by UEs
using the ULCoMP of scenario
1 in a collaborative neighboring
cell use the UL CoMP function.
N/A
UL CoMP
Users Num of
mixed Scenario
Number 0 to 1000 The eNodeB reports the number
of UEs using the UL CoMP in
mixed scenario to the M2000 at
the end of each monitoring
period.
UL CoMP Users of mixed
Scenario: UEs using the UL
CoMP of both scenario1 and
scenario 2 during a monitoring
period.
N/A
2.2 Satisfaction of Service Monitoring
2.2.1 Usage Scenario
This task is used to monitor the QoS satisfaction rate of VoIP services with QoS class
identifier (QCI) 1. This task is also used to monitor the QoS satisfaction rates of GBR services
with QCIs 2 to 4 in a cell based on the throughput. The QoS satisfaction rates of GBR
services indicate whether the QoS requirements of admitted GBR services are met and can be
used to determine the cell load status.
2.2.2 Service Impact
None.
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
9
2.2.3 Parameters
Table 2-3 Parameters for satisfaction of service monitoring
Parameter Description
Test Items It can be set to DL QCI1 Satisfaction rate of Service, DL QCI2
Satisfaction rate of Service, DL QCI3 Satisfaction rate of Service,
DL QCI4 Satisfaction rate of Service, UL QCI1 Satisfaction rate
of Service, UL QCI2 Satisfaction rate of Service, UL QCI3
Satisfaction rate of Service, UL QCI4 Satisfaction rate of Service,
Congestion State, or a combination of some items.
Local Cell ID ID of the cell on which satisfaction of service monitoring is
performed.
CN Operator ID In a RAN sharing scenario, a cell can be shared by a maximum of six
operators. In a non-RAN sharing scenario, a cell can be used by only
one operator.
Monitor Period
(ms)
Interval of reporting monitoring results. It can be set to 50, 100, 200,
500, 1000, or 2000.
2.2.4 Monitoring Results
Table 2-4 Results of satisfaction of service monitoring
Parameter Unit Value Range
Description Formula
CN
Operator ID
N/A 0 to 5 ID of the operator for which satisfaction
of service monitoring is performed.
N/A
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
10
Parameter Unit Value Range
Description Formula
CN
Operator
UL QCI[n]
Satisfaction
rate of
Service
% 0 to 100 Average QoS satisfaction rates of
different uplink services in a cell when
monitoring results are reported. n ranges
from 1 to 4. On the uplink, the uplink
QoS satisfaction rate of QCI1 is
represented by the average uplink VoIP
service satisfaction rate in a cell, that is,
the ratio of the total uplink VoIP service
satisfaction rates to the total number of
VoIP services in a cell. The higher the
proportion, the higher the satisfaction
rate.
The uplink QoS satisfaction rates of
GBR services with QCIs 2 to 4 are
evaluated for each logical channel group.
The QoS satisfaction rate of a logical
channel group is evaluated based on the
transmitted data and the total amount of
data to be transmitted. The higher the
transmitted data volume, the higher the
QoS satisfaction rate.
N/A
CN
Operator
DL QCI[n]
Satisfaction
rate of
Service
% 0 to 100 Average QoS satisfaction rates of
different downlink services in a cell
when monitoring results are reported.
The value range of n is 1 to 4. On the
downlink, the downlink QoS satisfaction
rate of QCI1 is represented by the
average downlink VoIP service
satisfaction rate in a cell, that is, the ratio
of the total downlink VoIP service
satisfaction rates to the total number of
VoIP services in a cell. The higher the
proportion, the higher the satisfaction
rate.
The downlink QoS satisfaction rates of
GBR services with QCIs 2 to 4 are
evaluated based on the ratio of the
scheduled data volume of these services
to the total data volume to be transmitted
for these services. If the scheduled data
volume is high or the data volume in the
buffer is low, the QoS satisfaction rate is
high.
N/A
Congestion
State
N/A Congesti
on,
Unconge
stion
Current congestion state of an operator
when monitoring results are reported.
N/A
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
11
2.3 General Throughput Monitoring
2.3.1 Usage Scenario
This task is used to monitor uplink and downlink throughput information about all UEs in a
cell in real time. Based on this information, the data transmission status of the eNodeB or UEs
can be determined.
2.3.2 Service Impact
None.
2.3.3 Parameters
Table 2-5 Parameters for general throughput monitoring
Parameter Description
Local Cell ID ID of the cell on which general throughput monitoring is
performed.
Test Items It can be set to RLC Throughput, RLC Throughput of GBR
service, RLC Throughput of NON-GBR service, or a
combination of some items.
CN Operator ID In a RAN sharing scenario, a cell can be shared by a maximum of
six operators. In a non-RAN sharing scenario, a cell can be used by
only one operator.
Monitor Period (ms) Interval of reporting monitoring results. It can be set to 50, 100,
200, 500, 1000, or 2000.
2.3.4 Monitoring Results
RLC Throughput
Table 2-6 Results of RLC Throughput monitoring
Parameter Unit Value Range
Description Formula
CN Operator ID N/A 0 to 5 ID of the operator for
which general
throughput monitoring
is performed.
N/A
Cell Uplink RLC
Throughput
bps 0 to
300000000
Uplink throughput of a
cell. Only RLC
payloads are included.
The RLC headers,
retransmitted data, and
state reports are
excluded.
(General uplink
RLC throughput
(byte) x 8) x
1000/Monitor
Period (ms)
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
12
Parameter Unit Value Range
Description Formula
Cell Downlink
RLC Throughput
bps 0 to
300000000
Downlink throughput
of a cell. Only the RLC
payloads are included.
The RLC headers,
retransmitted data, and
state reports are
excluded.
(General downlink
RLC throughput
(byte) x 8) x
1000/Monitor
Period (ms)
CN Operator Cell
Uplink RLC
Throughput
bps 0 to
300000000
Uplink RLC throughput
of an operator of a cell.
Only RLC payloads are
included. The RLC
headers, retransmitted
data, and state reports
are excluded.
(Uplink RLC
throughput of an
operator of a cell
(byte) x 8) x
1000/Monitor
Period (ms)
CN Operator Cell
Downlink RLC
Throughput
bps 0 to
300000000
Downlink RLC
throughput of an
operator of a cell. Only
RLC payloads are
included. The RLC
headers, retransmitted
data, and state reports
are excluded.
(Downlink RLC
throughput of an
operator of a cell
(byte) x 8) x
1000/Monitor
Period (ms)
RLC Throughput of GBR service
Table 2-7 Results of RLC Throughput of GBR service monitoring
Parameter Unit Value Range
Description Formula
CN Operator ID N/A 0 to 5 ID of the operator for
which general
throughput monitoring
is performed.
N/A
Cell GBR Traffic
Uplink RLC
Throughput
bps 0 to
300000000
Uplink throughput of
GBR services in a cell.
Only RLC payloads are
included. The RLC
headers, retransmitted
data, and state reports
are excluded.
(General RLC
throughput of
uplink GBR
services (Byte) x 8)
x 1000/Monitor
Period (ms)
-
eNodeB
Performance Monitoring Reference 2 Cell Performance Monitoring
Issue 07 (2013-11-30) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
13
Parameter Unit Value Range
Description Formula
Cell GBR Traffic
Downlink RLC
Throughput
bps 0 to
300000000
Downlink throughput of
GBR services in a cell.
Only RLC payloads are
included. The RLC
headers, retransmitted
data, and state reports
are excluded.
(General RLC
throughput of
downlink GBR
services (Byte) x 8)
x 1000/Monitor
Period (ms)
CN Operator Cell
GBR Traffic
Uplink RLC
Throughput
bps 0 to
300000000
Uplink GBR service
throughput of an
operator of a cell. Only
RLC payloads are
included. The RLC
headers, retransmitted
data, and state reports
are excluded.
(Uplink GBR
service throughput
of an operator of a
cell (byte) x 8) x
1000/Monitor
Period (ms)
Operator Cell GBR
Traffic Downlink
RLC Throughput
bps 0 to
300000000
Downlink GBR service
throughput of an
operator cell. Only RLC
payloads are included.
The RLC headers,
retransmitted data, and
state reports are
excluded.
(Downlink GBR
service throughput
of an operator of a
cell (Byte) x 8) x
1000/Monitor
Period (ms)
RLC Throughput of NON-GBR service
Table 2-8 Results of RLC Throughput of NON-GBR service monitoring
Parameter Unit Value Range
Description Formula
CN Operator ID N/A 0 to 5 ID of the operator for
which general
throughput monitoring
is performed.
N/A
Cell Non-GBR
Traffic Uplink
RLC Throughput
bps 0 to
300000000
Uplink throughput of
non-GBR services in a
cell. Only RLC
payloads are included.
The RLC headers,
retransmitted data, and
state reports are
excluded.
(General RLC
throughput of
uplink non-GBR
services (Byte) x 8)
x 1000/Mo