environment lab equipment

Upload: bedatrayee05

Post on 03-Jun-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/11/2019 Environment Lab Equipment

    1/38

    Sr.

    No

    App.Cost* Qnt.

    1 66,975 1

    Bench top Microprocessor pH meter

    should include Meter with integral

    magnetic stirrer, pH electrode,

    Temperature Sensor, Integral Sensor

    holder/stand, Standard Solutions: pH 4,

    7, 9 Calibration flasks with

    magnetic stirring bar. Meter and Probe

    should be water proof. Mode ofoperation: fully automated / semi -

    automated / manual: Automatic Buffer

    recognition technical and up to 3

    custom buffers chosen by the user.

    CIVIL ENGG. DEPARTMENT

    ENVIRONMENTAL ENGINEERING LAB.

    Specification of Equipment

    LABORATORY BENCH TOP PH

    METER

    The instrument should includes:

    Bench top pH Meter

    pH electrode + ATC, low

    maintenance, plastic body, gel for

    general applications

  • 8/11/2019 Environment Lab Equipment

    2/38

  • 8/11/2019 Environment Lab Equipment

    3/38

    Data Storage : GLP features

    (Date/Time, Sample

    ID, User ID)

    Temperature

    Correction/

    Compensation:

    pH: Automatic with

    temperature probe (pt

    1000)

    Power supply : External power

    supply 240 V,

    Connectable

    Peripherals

    Magnetic stirrer.

    Materials Enclosure, ABS and

    PC. Keypad, PET.

    Physical

    Parameters(Met

    er)

    Weight: 800 g. Size:

    350 x 200 x 110 mm.

    2 101,650 1

    Warranty:- 1 Year

    Training Include

    LABORATORY BENCHTOP

    CONDUCTIVITY/TDS METER

  • 8/11/2019 Environment Lab Equipment

    4/38

    Conductivity

    Range

    0.2 S/cm to 200

    mS/cm

    Probe holder

    storage solutions

    Probe protector tube

    Calibration beakers

    Power supply with plug adapters

    Bench Top Microprocessor conductivity

    /TDS meter should be include: complete

    meter, probe, Temperature Sensor

    workstation with integrated stirrer, buffers,

    standards, storage solutions, calibration

    flasks. The system should be single probe

    input display system suitable for

    measurement of Conductivity, Resistivity,Salinity, TDS & Temperature. Meter and

    Probe should be water proof. The meter

    should be able to connect with 220 Volts

    through adapter. Mode of operation: fully

    automated / semi -automated / manual with

    automatic temperature compensation.

    The equipment should includes:-

    Benchtop Conductivity Meter

    Condutivity/TDS electrode

    Workstation with built-in strirrer and

    control

    Technical specifications

  • 8/11/2019 Environment Lab Equipment

    5/38

    Resolution: 0.00 to 199.9 mS/cm

    (Auto ranging, 5 digits

    maximum)

    Total Dissolved

    Solids Range

    0.1 mg/L to 128 g/L,

    Resolution : 0 to 9.99, 99.9, 999

    mg/L,9.99, 199.9 g/L

    Salinity range 0 mg/L to 200 g/L

    Resolution 0.0 to 1999 mg/L, 2.0 to

    50.0 g/L

    Resistivity Range 0 M Ohm to 500 M

    Ohm

    Resolution 0.0 to 1999 mg/L

    Temp. 0 to 80 C

    Resolution 0.1C

    Accuracy > 0.3 C

    Data Logging 400 measurements

    Data Export sent to printer or PC

    through the RS 232 C.

    Display: LCD with backlight

    Data Storage : GLP features

    (Date/Time, Sample ID,

    User ID)

    Temperature

    Correction/

    Compensation:

    Automatic with

    temperature probe

    Power supply : External power supply

    240 V,

    Cable Length 1 Meter

    3 138,225 1

    Warranty:- 1 Year

    Training Include

    Laboratory Multiparameter for LDO

    Analysis

  • 8/11/2019 Environment Lab Equipment

    6/38

    Range: 0.05 to 20.00

    mg/L (0 to 200%)

    Resolution: 0.01 mg/L

    DO

    Range/Resolution

    Digital multi-parameter Meter having plug

    and play operation to be supplied LDO

    probes with necessary calibration and

    maintenance accessories in a complete set.

    The instrument shall have facility to plug

    in any two probes and get simultaneous

    measurement; simultaneous readout. The

    instrument should feature AutomaticTemperature Compensation. The meters

    should be able to store probe serial

    numbers, calibration history, user ID, time,

    date and location of readings. Should have

    facility to transfer GLP/ISO data

    effortlessly to a PC or USB flash stick. The

    meter should be password protected for

    accurate tamperproof readings.

    The meter must be operable with normal

    AA batteries and optionally with power.

    The supplied probes should be rugged,

    designed for harsh environments. Probe

    should be able to store its calibration

    history in the probe itself, minimizing

    probe replacement and calibration, Should

    feature Calibration Alert facility.

    Technical specifications

  • 8/11/2019 Environment Lab Equipment

    7/38

    Range: -10.0 to

    110.0C

    Resolution: 0.1C

    Accuracy: 0.3C

    (0.54F)

    Result Display Display readings from

    one probe or

    simultaneous readingfrom two probes

    Memory 500 data points

    Data Storage GLP/ISO compliant

    reading data stored with

    calibration details.

    Calibration details and

    check standard readings

    documented as events in

    log. Automatically store

    in mode and interval

    measurement mode.

    Manually store in

    mode.

    Water Resistance Meter Casing: 1 meter

    submersion for 30

    minutes

    4 56,414 1

    Temperature

    Range/Resolution

    /Accuracy

    Warranty:- 1 Year

    Training Include

    Digital Titrator:-

    Digital Titrator, 0.00125 mL/digit, with

    case, manual, and five straight delivery

    tubes.Interchangeable cartridges which

    allow to change titrants in seconds. No

    cleaning or rinsing burets. More than 50

    parameter/range combinations ,

    Concentrated titrants should allow 40-100

    typical titrations per cartridge.

  • 8/11/2019 Environment Lab Equipment

    8/38

    5 95,000 1

    Techanical Specification:-

    Accuracy: 1 % (Uncertainty of readings is

    1 digit. )

    Weight:0.29 lbs. (0.132 kg)

    Equipment should includes:-

    a) Digital Titrator Qty 1.

    b) Alkalinity Cartridge Approx

    Test 200

    c) Acidity Cartridge Approx

    Test 200

    d) Total Hardness Cartridge

    Approx Test 200

    Warranty:- 1 Year

    Training Include

    Portable Turbidity Meter:-

    Equipment should includes:

    Four AA alkaline batteries, a carrying casewith insert, primary calibration standards

    in 1 sealed vials (20, 100, 800 NTU), a 10

    NTU primary verification standard, 6

    sample cells with screw-tops, instrument

    manual (printed and on CD-ROM), quick

    start guide, silicone oil and oiling cloth.

    Technical Specification:-

  • 8/11/2019 Environment Lab Equipment

    9/38

    Ratio turbidity metric determination using

    a primary nephelo metric light scatter

    signal (90) to the transmitted light scatter

    signal.

    Regulatory: 2100Q: Meets EPA Method180.1

    Light Source: 2100Q: Tungsten filament

    lamp

    Range: 0 to 1000 NTU (FNU)

    Accuracy: 2% of reading plus stray light

    from 0 to 1000 NTU

    Repeatability: 1% of reading, or 0.01

    NTU (FNU), whichever is greater

    Resolution: NTU on lowest range

    Stray Light:

  • 8/11/2019 Environment Lab Equipment

    10/38

    6 207,400 1

    0 to 80% @ 40C, 0 to 70% @ 50C, no

    condensing

    Storage Conditions

    -40 to 60C (-40 to 140F), instrument only

    Warranty:- 1 YearTraining Include

    Portable TSS Analyser

    TSS Analyser should includes :

    The instrument should measure Turbidity,

    Suspended Solids, and Sludge Blanket

    Level with multi-beam alternating light

    method with infrared diode system.

    Should be capable to store up to four

    different calibration curves for suspended

    solids and one for turbidity.

    Instrument should not require need for

    constant re-calibration for different

    locations or types of sludge.

    The sludge blanket level should be

    measured by setting the units to mg/L, g/L

    or percent.

    The instrument software shouldcompensate for air bubbles to prevent its

    influence on the measurement.

  • 8/11/2019 Environment Lab Equipment

    11/38

    The probe should be made of good material

    which should be scratch-resistant to

    withstand harsh environments.

    The internal memory of equipment should

    be able to store at least 200 measuring

    values, including time, date, measurement,

    location, and homogeneity.

    Technical Specifications

    Accuracy for measurement of Turbidity:

    less than 3 % or 0.02 NTU whichever is

    greater

    Accuracy for measurement of suspended

    solids: less than 4 % or 0.001 g/L,

    whichever is greater

    Accuracy for measurement of TSS

    Content: < 0.04 or 0.02 FNU (whichever

    is greater)

    Interface: RS485

    Range for Suspended Solids : 0.001 to 400

    gm/l(1 to 400,000 mg/l)

    Measuring Range Turbidity: 0.001 to 9999FNU

    Warranty:- 1 Year

    Training Include

  • 8/11/2019 Environment Lab Equipment

    12/38

    7 433,320 1BOD Meter & BOD Incubator with

    Reagent:-

    BOD Meter-

    BOD Meter should measure BOD from 0

    700 mg/l without any sample dilutions.Meter shall give the results directly in ppm

    and also shall show the BOD trend during

    entire test length for each measurement

    channel. Meter shall have at least 6

    measuring channels. Meter shall be

    compact enough to fit in to standard BOD

    incubators available in the laboratory.

    Meter shall be operated through soft touch

    keypad for channel selection, control

    settings etc., and shall shut off

    automatically after the test length. Metershall store data of all measuring channels

    for the entire test length. Stored data shall

    be compatible to direct transfer to a PC.

    Meter shall meet the following functional

    specifications:

    Specifications:

  • 8/11/2019 Environment Lab Equipment

    13/38

    Range :Selectable, 0 to

    35 mg/L, 0 to

    70mg/L, 0 to 350

    mg/L,

    0 to 700 mg/L

    Test Duration :Selectable, 5-

    ,7-, 10-, or 30 day test

    Capacity :Six 473-ml BOD

    bottles

    Power : 230 Vac,

    50/60 Hz

    Computer interface :RS232

    Display :Graphical LCD for

    continuous

    updates on

    BOD test

    results and

    status.

    Data collection and storage:Automated on

    each test run.

    Equipment should include:

    Meter should supplied with 6 473ml amber

    colored BOD bottles, Nutrient solution for

    50 tests, CO2absorbing Power packs for

    50 tests, 6 holding cups for CO2absorbing

    powder, grease tube, Power adapter and

    instrument operation manual.

    BOD Incubator-

  • 8/11/2019 Environment Lab Equipment

    14/38

    Incubating cultures of micro organisms,

    storing samples, determining enzymatic

    activity, and all uses requiring that

    products be kept at a constant and precise

    temperature. Continuous ventilation and

    the special microprocessor controlled

    AUTO-TUNING thermoregulation systemensure temperature uniformity in all points

    inside the chamber with continuous

    monitoring of the room temperature so the

    Set Point set is kept precisely aligned. The

    internal temperature is programmed and

    displayed digitally with selection of the

    tenth degree Celsius from 3 to 50C

    (stability 0.5C). Can be connected to a

    PC using an RS232 connector for use with

    dedicated software.

    GENERAL FEATURES

    Total volume: 207 liters

    Usable internal volume: 196 liters (6.92

    Cu Ft) Number of sockets: 2 internal

    electrical current socket Number of shelves

    included: 4 Max number of shelves: 12

    (distance of 40 mm between one shelf and

    the next)

  • 8/11/2019 Environment Lab Equipment

    15/38

    8 227,930 1

    Electronic thermoregulation

    system: AUTO - TUNING

    Transparent internal door, yes

    Power: 350 W

    Power supply: 230 V / 50-60 Hz

    Weight: 40 Kg

    Dimension (WxHxD): 540x1300x560 mm

    PERFORMANCES

    Temperature range:, from 3.0 to 50.0C

    Internal temperature stability: 0.5C

    Internal temperature homogeneity: 0.5C

    Internal temperature visualization: display

    Temperature resolution: 0.1C

    Warranty:- 1 Year

    Training Include

    Portable Colorimeter:-

    Colorimeter should includes:-

    Auto-wavelength selection,

    datal logging capabilities and user-

    generated calibrations.

  • 8/11/2019 Environment Lab Equipment

    16/38

    Durable, hand-held, filter

    photometers with rugged

    components and waterproof,

    dustproof, chemical-resistant

    housings. Equipment should offer

    simple, push-button program

    selection and step-by-step

    programme for the user guidance.

    Colorimeter should preprogrammed to

    measure COD, Aluminum, Ammonia,

    Bromine, Chlorine, Chromium, Fluoride,

    Iron, Manganese, nickel, nitrate, nitrite,

    Ammonia-Nitrogen, Total Kjeldahl

    Nitrogen, Phosphorous, Silica, Sulfides,

    Sulfates, TOC, Suspended solids, Zinc etc.

    Colorimeter should further meet the

    following specifications:-

    Wavelength Selection: Auto Select

    Photometric Range: 0 to 2 Abs

    Operational Modes: Concentration, Abs,

    %T

    External Outputs: Infrared to RS-232Serial using the optional Data Transfer

    Adapter

  • 8/11/2019 Environment Lab Equipment

    17/38

    Data logging: 99 sample readings (each

    reading includes date/time, parameter,

    program number, concentration,

    absorbance, % transmittance, sample

    number, instrument serial number)

    User Programs: 10 user-entered programs,

    12 data points each

    Display: Large liquid-crystal display

    (LCD) shows results, parameter name,

    program number and units

    Weight: 470 g (1 lb)

    Power: 4 AA alkaline or rechargeable

    alkaline batteries, nominal life of six

    months

    Storage Temperature Range: -40 to 60C (-

    40 to 140F)

    Operating Temperature Range: 0 to 50C

    (32 to 122F)

    Environmental: Dustproof and waterproof

    to one meter for 30 minutes

    The equipment should include

    a) COD Digestion Reactor

  • 8/11/2019 Environment Lab Equipment

    18/38

    The digestion reactor shall be a bench top

    instrument for heating prepared samples to

    temperature for the designated time for the

    COD test. The instrument shall have a

    LCD display and shall have facility for

    programmable temperature range of 37 to

    165C in 1oC increment. The

    programmable timer range should be from0 to 480 minutes. Reactor shall emit an

    audible signal automatically and shut down

    at the end of the digestion time. The

    instrument should have a heating rate of 20

    to 150C in 10 minutes. The instrument

    shall be equipped with stored digestion

    programs for COD and TOC. The reactor

    shall also be capable of storing 3 user

    defined methods for digestion. The

    instrument shall have Heating blocks to

    accommodate 16-mm and or 20-mm vials

    in total. Heating blocks shall be able to settemperature and timers independently

    allowing to use the reactor for two testing

    methods. Heating blocks shall be covered

    with transparent lids for operator safety.

    The power requirements of the instrument

    shall be 100-240 Vac, 50/60 Hz.

    Technical Specification:-

    Programmable Temperature Range: 37

    to 165C (99 to 329F)

    Operating Temperature: 10 to 45 C

    50 to 113FProgrammable Timer Range: 0 to 480

    minutes

    Heating Rate: 20 to 150C in 10

    minutes

    Temperature Stability: 1C

    Stored Programs

    COD 150C 120 minutes

    TOC 105C 120 minutes

    Fixed 100, 105, 30, 60,

    150, 165C 120 minutes

    Power Requirements:

    100 to 240 VAC, 50/60 Hz, 600 VA

    Compliance: CE, GS, CTUVUS

    Dimensions:

  • 8/11/2019 Environment Lab Equipment

    19/38

    1326914

    25.0 x 14.5 x 31.0 cm (9.8 x 5.7 x 12.2

    in.)

    Number of Vial Wells

    Single block: 9 16-mm and 2 20-mm or

    15 16-mm

    Total cost

    The equipment should be supplied with

    following regents.

    b) Reagent for Chloride Testing-

    200 Test

    c) Reagent for Sulphate Testing-

    200 Test

    d) Reagent for COD Testing-

    300 Test Range- 0 to 1500mg/l

    Warranty:- 1 Year

    Training Include

  • 8/11/2019 Environment Lab Equipment

    20/38

  • 8/11/2019 Environment Lab Equipment

    21/38

  • 8/11/2019 Environment Lab Equipment

    22/38

    5082.5 106,733

  • 8/11/2019 Environment Lab Equipment

    23/38

  • 8/11/2019 Environment Lab Equipment

    24/38

  • 8/11/2019 Environment Lab Equipment

    25/38

  • 8/11/2019 Environment Lab Equipment

    26/38

    2820.7 59,235

  • 8/11/2019 Environment Lab Equipment

    27/38

    4750 99,750

  • 8/11/2019 Environment Lab Equipment

    28/38

  • 8/11/2019 Environment Lab Equipment

    29/38

    10370 217,770

  • 8/11/2019 Environment Lab Equipment

    30/38

  • 8/11/2019 Environment Lab Equipment

    31/38

    21666 454,986

  • 8/11/2019 Environment Lab Equipment

    32/38

  • 8/11/2019 Environment Lab Equipment

    33/38

  • 8/11/2019 Environment Lab Equipment

    34/38

    11396.5 239,327

  • 8/11/2019 Environment Lab Equipment

    35/38

  • 8/11/2019 Environment Lab Equipment

    36/38

  • 8/11/2019 Environment Lab Equipment

    37/38

  • 8/11/2019 Environment Lab Equipment

    38/38

    1393259.7