EP Model Water Source Heat Pump ½ to 6 Ton Commercial Sales Catalog boschheatingandcooling.com Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements. UP TO 21.7 EER UP TO 6.0 COP EP Model GLHP WSHP

Upload: others

Post on 17-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • EP Model Water Source Heat Pump½ to 6 Ton

    Commercial Sales Catalogboschheatingandcooling.com

    Industry-leading single-stage efficiencies, standard features, and a variety of options - providing energy efficient solutions to accommodate your building requirements.

    UP TO21.7EER

    UP TO6.0COP

    EPModel

    GLHP WSHP

  • Enhanced EP ModelThe EP Model, water-to-air heat pump offers high efficiency, value added features and a single stage compressor (scroll type 1 1/2 - 6 ton size). An optional ECM constant airflow fan motor can give you the flexibility, performance and quiet operation needed to meet the expectations of your clients.

    ECM Constant Airflow Fan MotorThe high efficiency Electrically Commutated Motor (ECM), available in 1/3hp to 1hp, provides constant airflow in a wide static pressure range up to 1 in.w.g. Optional in all unit sizes except 1/2 through 1 ton, this motor is a great choice in high filtration applications. The motor has a soft start/stop feature, keeping noise to a minimum. Passive dehumidification can be achieved with the constant airflow ECM by reducing nominal airflow by 15%. This control feature lowers air coil temperature and prevents over-cooling of the space when in dehumidification mode. The constant airflow ECM requires a neutral wire in a 460V application.

    Blower and MotorPSC blower motors are standard on unit sizes 1/2 through

    1 ton. Multiple speed constant torque ECM motors are standard on units sizes 1 1/2 through 6 tons, allowing the user to select the correct speed to deliver the specified airflow and the design system static pressure.

    MERV-8 and MERV-13 Filters The optional 2" MERV-8 or -13 filter is most advantageous for premium air filtration on commercial HVAC projects. High efficiency filtration is a cost-effective way of upgrading air quality while maintaining low pressure drop and sustaining long service life. These filters effectively remove up to 98% of airborne matter, such as fine particulates, bacteria, smoke, gases and allergens including dust mites, pollen, mold spores, dust and smog. MERV-8 and MERV-13 rated filters are a minimum requirement for EQ credits

    Quiet Comfort Floating Compressor Base - Reduces vibration and noise transmission from the compressor to the structure Closed-cell Foam Insulation (option) - Helps to provide cleaner, fiber-free air and reduces sound transmission Compressor Blanket (option) - Offers optimum low sound levels (not available on smaller units with rotary compressor)

    Service Friendly Blower Inlet Ring - (available in 015-070 only) Allows quick servicing of blower fan motor without disassembly of blower housing Insulated Divider - Separates the compressor and blower sections, allowing the unit to be serviced easily during operation Schrader Charging Valves - Facilitates service diagnosis by allowing the connection of refrigerant hoses quickly and securely

    Robust and Durable Construction Galvanized Steel Cabinet - Provides strength and corrosion protection Evaporator Coil Protection with DuoGuard™ (option) - Tin electro-plated copper tubing with high-tech polymer coated aluminum fins that aid in protecting the evaporator coil from most forms of corrosive elements in the air stream Stainless Steel Drain Pan - Resists cracking and corrosion which provides long-lasting reliability for condensate collection Cupro-nickel Coaxial Heat Exchanger (option) - Protects against corrosion when water conditions are of low quality 40A Non-fused disconnect (option) - Allows shut off of the unit without lockout of the main panel (N/A with electric heat)

    Safety Flow Proving Switch (option) - Prevents the operation of the compressor should the water supply fail Unit Protection Module (UPM) - Monitors the unit operation and safety controls that protect the unit Dual Refrigerant Freeze Sensors - Monitors if refrigerant temperatures reach freeze limits and disables unit to protect it

    Quality Design & Efficiency Boilerless Control (option) - Disables the compressor and/or activates electric heater should the water temperature drop below adjustable set point Water Side Economizer (option) - Provides free-cooling without the use of mechanical cooling (compressors) Extended Range (option) - Accommodates geothermal closed loop applications when Entering Fluid Temperatures are anticipated below 60 °F TXV - Bi-flow thermal expansion valve for optimum performance over a wide range of heating and cooling conditions Heat Recovery Package (option for 024-070 in -1 or -3 voltage only) - Provides domestic water heating during the air conditioning or heating mode to supplement your building's potable water heating needs assisting any electric domestic water heating storage tank

    Commercial Water Source Heat Pumps

    Features Designed for any Application

  • ModelVertical Unit

    Dimensions (in inches)A (width) B (depth) C (height)

    EP007 21.75 21.75 32.75EP009 21.75 21.75 32.75EP012 21.75 21.75 32.75EP015 21.75 21.75 39.25EP018 21.75 21.75 39.25EP024 21.75 26.25 47.25EP030 24.25 33.50 47.25EP036 24.25 33.50 47.25EP042 26.25 33.50 58.25EP048 26.25 33.50 58.25EP060 26.25 33.50 66.25EP070 26.25 33.50 66.25

    Technical SpecificationsModel

    Horizontal Unit Dimensions (in inches)

    A (width) B (depth) C (height)

    EP007 21.75 43.25 16.75EP009 21.75 43.25 16.75EP012 22.25 45.25 19.75EP015 22.25 45.25 19.75EP018 22.25 45.25 19.75EP024 26.25 54.75 22.00*EP030 30.25 68.25 22.00*EP036 30.25 68.25 22.00*EP042 30.25 79.00 22.00*EP048 30.25 79.00 22.00*EP060 30.25 89.25 22.00*EP070 30.25 89.25 22.00*

    All dimensions in inches unless otherwise noted. All dimensions within +-0.125". Specifications subject to change without notice. *Total unit height is 22.75 with base rails for EP030 - EP070.

    A B

    C

    BA

    C

    3.1 and 5 on LEED® projects. Note: MERV-13 factory option requires ECM Constant Airflow fan motor option. With the optional ECM constant airflow motor the EP is prepared to handle higher external pressure drops when utilizing the higher efficiency MERV-13 filters.

    DDC Controls The optional factory mounted DDC Controller is preprogrammed and installed on the unit with the Unit Protection Module (UPM) to be job site ready. With a factory-supplied DDC wall sensor, the unit will operate in a 100% stand-alone control mode or connect to a Building Automation System (BAS) using open protocols BACnet™, Modbus, N2 or LonWorks® (with an optional Lon card).

    DDC Room and Zone Sensors (optional)To complement the controller, Bosch Thermotechnology Corp.

    offers a line of intelligent FHP space sensors, which provide precision measurement and communication capabilities in an attractive low profile enclosure.

    Additional Options 5, 10, 15, 20 kW electric heaters Relays - EMS, blower monitor, compressor monitor, and pump/valve Fire alarm/dual power Comfort alert module 2-Way internal solenoid valve Autoflow water regulator valve Hot gas bypass Hot gas reheat Straight cooling

    Horizontal

    Vertical

    ASHRAE / AHRI / ISO 13256-1. English (I-P) Units

    Model

    Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat PumpCooling 86˚F Heating 68˚F Coolng 59˚F Heating 50˚F Cooling 77˚F Heating 32˚F

    Capacity Btuh

    EER Btuh/W

    Capacity Btuh COP

    Capacity Btuh

    EER Btuh/W

    Capacity Btuh COP

    Capacity Btuh

    EER Btuh/W

    Capacity Btuh COP

    EP with PSC MotorEP007 6,800 15.7 8,800 5.7 8,400 25.1 7,000 4.9 7,400 18.5 5,100 3.6

    EP009 9,000 16.2 11,200 5.5 10,500 25.5 9,000 4.5 9,500 19.3 6,800 3.6

    EP012 12,200 14.9 16,500 5.1 114,600 22.7 13,000 4.3 13,000 17.5 10,000 3.6

    EP with ECM Motor (Constant Torque or Constant Air Flow)EP015 15,200 17.5 17,500 5.6 17,000 28.8 13,000 4.6 16,200 20.6 11,000 3.9

    EP018 19,500 16.4 21,300 5.3 21,300 25.6 17,700 4.5 20,500 19.0 14,800 3.8

    EP024 24,500 18.2 28,500 5.7 28,400 28.1 23,700 4.6 26,000 21.1 18,000 4.0

    EP030 27,000 16.6 31,000 5.9 31,700 27.0 25,000 5.2 28,500 19.4 20,500 4.3

    EP036 36,000 17.2 41,000 5.6 40,200 25.9 34,400 4.9 37,500 19.7 26,000 4.1

    EP042 40,600 18.2 42,400 6.0 45,000 25.7 35,000 5.1 42,200 21.7 26,800 4.1

    EP048 47,400 17.2 50,000 5.3 52,900 26.1 40,500 4.3 49,500 20.0 33,400 3.7

    EP060 60,400 16.2 71,500 5.7 66,500 24.1 56,700 4.9 61,500 18.5 47,000 4.2

    EP070 68,000 16.2 86,000 5.6 71,400 22.4 71,400 5.0 70,500 18.5 56,500 4.2

    Tabulated performance data is at noted water temperatures and entering air conditions of 80.6°F DB/66.2°F WB at ARI/ISO 13256-1 rated CFM.

  • Model Voltage Code Voltage/Ph/HzCompressor Blower

    Min Circuit Amps Max Fuse

    Quantity RLA LRA Quantity FLA HP

    EP007-1 208-230/1/60 1 2.5 17.7 1 0.96 0.1 4.1 15

    -2 265/1/60 1 2.6 13.5 1 0.85 0.1 4.1 15

    EP009-1 208-230/1/60 1 3.4 22.2 1 0.96 0.1 5.2 15

    -2 265/1/60 1 2.9 18.8 1 0.85 0.1 4.5 15

    EP012

    -0 115/1/60 1 9.6 58.4 1 2.2 0.1 14.2 20

    -1 208-230/1/60 1 4.6 27.9 1 0.96 0.1 6.7 15

    -2 265/1/60 1 3.8 22.2 1 0.85 0.1 5.6 15

    EP015-1 208-230/1/60 1 5.6 29 1 2.8 0.33 9.8 15

    -2 265/1/60 1 4.6 20 1 2.6 0.33 8.4 15

    EP018-1 208-230/1/60 1 7.4 33 1 2.8 0.33 12.1 15

    -2 265/1/60 1 6 28 1 2.6 0.33 10.1 15

    EP024

    -1 208-230/1/60 1 13.5 58.3 1 2.8 0.33 19.7 30

    -2 265/1/60 1 9 54 1 2.6 0.33 13.9 20

    -3 208-230/3/60 1 7.1 55.4 1 2.8 0.33 11.7 15

    -4 460/3/60 1 3.5 28 1 2.1 0.5 6.5 15

    EP030

    -1 208-230/1/60 1 12.8 58.3 1 4.1 0.5 20.1 30

    -2 265/1/60 1 9.6 54 1 3.6 0.5 15.6 25

    -3 208-230/3/60 1 7.7 55.4 1 2.8 0.5 12.4 20

    -4 460/3/60 1 3.6 28 1 2.1 0.5 6.6 15

    EP036

    -1 208-230/1/60 1 16 77 1 6 0.75 26.0 40

    -3 208-230/3/60 1 10 71 1 6 0.75 18.5 25

    -4 460/3/60 1 4.7 38 1 4.6 0.75 10.5 15

    EP042

    -1 208-230/1/60 1 16.7 79 1 6 0.75 26.9 40

    -3 208-230/3/60 1 10.4 73 1 6 0.75 19.0 25

    -4 460/3/60 1 5.8 38 1 4.6 0.75 11.9 15

    EP048

    -1 208-230/1/60 1 19.9 109 1 6 0.75 30.9 50

    -3 208-230/3/60 1 13.6 83.1 1 6 0.75 23.0 35

    -4 460/3/60 1 6.1 41 1 4.6 0.75 12.2 15

    EP060

    -1 208-230/1/60 1 25 134 1 7.6 1 38.9 60

    -3 208-230/3/60 1 15.9 110 1 7.6 1 27.5 40

    -4 460/3/60 1 7.1 52 1 4 1 12.9 20

    EP070

    -1 208-230/1/60 1 26.3 134 1 7.6 1 40.5 60

    -3 208-230/3/60 1 15.6 110 1 7.6 1 27.1 40

    -4 460/3/60 1 7.8 52 1 4 1 13.8 20

    Electrical Data

    Model Voltage Code Voltage/ Phase/HzVoltage

    Min/Max

    Compressor Compressor Electrical Sizing

    Quantity RLA LRA Min Circuit AmpsMax Fuse/

    HACR

    EP018 1 208-230/60/1 197/253 1 7.4 33.0 9.3 15

    EP024 1 208-230/60/1 197/253 1 13.5 58.3 16.9 30

    EP030 1 208-230/60/1 197/253 1 12.8 58.3 26.5 25

    EP036 1 208-230/60/1 197/253 1 16.0 77.0 20.0 30

    EP042 1 208-230/60/1 197/253 1 16.7 79.0 20.9 30

    EP048 1 208-230/60/1 197/253 1 19.9 109.0 24.9 40

    EP060 1 208-230/60/1 197/253 1 25.0 134.0 31.3 50

    EP070 1 208-230/60/1 197/253 1 26.3 134.0 26.5 50

    Standard Motor – PSC for 007-012, ECM Constant Torque for 015-070

    NOTE: For the wiring diagram please refer to pages 33 and 34 in the Installation & Maintenance Manual (IOM)

    For units with a factory installed heater kit option, there will be two separate data plates for each electrical circuit. The first data plate will be for the compressor power connection.

    boschheatingandcooling.com

  • Electrical Data

    For Units with Internal Electric Heat Option — Constant Torque ECM Motor

    ModelEH

    RatedkW

    StageHeater Watts Heater AMPS Circuit MCA MOP

    240 208 240V 208V Motor FLA (A) Fuses 240V 208V 240V 208V

    EP018 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30EP024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30EP024 9.6 1 9,600 7,200 40.0 34.6 2.8 - 53.5 46.8 60 50EP030 4.8 1 4,800 3,600 20.0 17.3 4.1 - 30.1 26.8 35 30EP030 9.6 1 9,600 7,200 40.0 34.6 4.1 - 55.1 48.4 60 50EP036 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30EP036 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60

    EP036 14.4 2 14400 10800 60 51.9 6 F1/F2 82.5 72.4 90 80F3/F4

    EP042 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30EP042 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60

    EP042 14.4 2 14400 10800 60 51.9 6 F1/F2 82.5 72.4 90 80F3/F4

    EP048 4.8 1 4,800 3,600 20.0 17.3 6.0 - 32.5 29.1 35 30EP048 9.6 1 9,600 7,200 40.0 34.6 6.0 - 57.5 50.8 60 60

    EP048 14.4 2 14400 10800 60 51.9 6 F1/F2 82.5 72.4 90 80F3/F4

    EP048 19.2 2 19200 14000 80 69.2 6 F1/F2 107.5 94.0 110 100F3/F4

    EP060 4.8 1 4,800 3,600 20.0 17.3 7.6 - 34.5 31.1 35 35EP060 9.6 1 9,600 7,200 40.0 34.6 7.6 - 59.5 52.8 60 60

    EP060 14.4 2 14400 10800 60 51.9 7.6 F1/F2 84.5 74.4 90 80F3/F4

    EP060 19.2 2 19200 14000 80 69.2 7.6 F1/F2 109.5 96.0 110 100F3/F4

    EP070 4.8 1 4,800 3,600 20.0 17.3 7.6 - 34.5 31.1 35 35EP070 9.6 1 9,600 7,200 40.0 34.6 7.6 - 59.5 52.8 60 60

    EP070 14.4 2 14400 10800 60 51.9 7.6 F1/F2 84.5 74.4 90 80F3/F4

    EP070 19.2 2 19200 14000 80 69.2 7.6 F1/F2 109.5 96.0 110 100F3/F4

    ECM Constant Airflow Motor

    Model Voltage Code Voltage/Ph/HzCompressor Blower Min Circuit

    Amps Max FuseQuantity RLA LRA Quantity FLA HP

    EP015 -1 208-230/1/60 1 5.6 29 1 2.8 0.33 9.8 15-2 265/1/60 1 4.6 20 1 2.6 0.33 8.4 15

    EP018 -1 208-230/1/60 1 7.4 33 1 2.8 0.33 12.1 15-2 265/1/60 1 6 28 1 2.6 0.33 10.1 15

    EP024

    -1 208-230/1/60 1 13.5 58.3 1 2.8 0.33 19.7 30-2 265/1/60 1 9 54 1 2.6 0.33 13.9 20-3 208-230/3/60 1 7.1 55.4 1 2.8 0.33 11.7 15-4 460/3/60* 1 3.5 28 1 4.1 0.5 8.5 15

    EP030

    -1 208-230/1/60 1 12.8 58.3 1 4.3 0.5 20.3 30-2 265/1/60 1 9.6 54 1 4.1 0.5 16.1 25-3 208-230/3/60 1 7.7 55.4 1 4.3 0.5 13.9 20-4 460/3/60* 1 3.6 28 1 4.1 0.5 8.6 15

    EP036-1 208-230/1/60 1 16 77 1 6.8 0.75 26.8 40-3 208-230/3/60 1 10 71 1 6.8 0.75 19.3 25-4 460/3/60* 1 4.7 38 1 5.5 0.75 11.4 15

    EP042-1 208-230/1/60 1 16.7 79 1 6.8 0.75 27.7 40-3 208-230/3/60 1 10.4 73 1 6.8 0.75 19.8 30-4 460/3/60* 1 5.8 38 1 5.5 0.75 12.8 15

    EP048-1 208-230/1/60 1 19.9 109 1 6.8 0.75 31.7 50-3 208-230/3/60 1 13.6 83.1 1 6.8 0.75 23.8 35-4 460/3/60* 1 6.1 41 1 5.5 0.75 13.1 15

    EP060-1 208-230/1/60 1 25 134 1 9.1 1 40.4 60-3 208-230/3/60 1 15.9 110 1 9.1 1 29.0 40-4 460/3/60* 1 7.1 52 1 6.9 1 15.8 20

    EP070-1 208-230/1/60 1 26.3 134 1 9.1 1 42.0 60-3 208-230/3/60 1 15.6 110 1 9.1 1 28.6 40-4 460/3/60* 1 7.8 52 1 6.9 1 16.7 20

    *Electric heat is not available for horizontal-straight through airflow configuration or with hot gas reheat. Units with electric heat require dual point power connections. Chart above is for the blower and heater only. Refer to catalog for compressor electrical data.

    * 460V models with a constant airflow motor require a neutral wire to provide 265V power to the motor.

  • Electrical DataFor Units with Internal Electric Heat Option — Constant Airflow ECM Motor

    ModelEH

    RatedkW

    Stage

    Heater Watts Heater AMPS Ciruit MCA MOP

    240 208 240V 208V Motor FLA (A) Fuses 240V 208V 240V 208V

    EP018 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30

    EP024 4.8 1 4,800 3,600 20.0 17.3 2.8 - 28.5 25.1 30 30

    EP024 9.6 1 9,600 7,200 40.0 34.6 2.8 - 53.5 46.8 60 50

    EP030 4.8 1 4,800 3,600 20.0 17.3 4.3 - 30.4 27.0 35 30

    EP030 9.6 1 9,600 7,200 40.0 34.6 4.3 - 55.4 48.6 60 50

    EP036 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35

    EP036 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60

    EP036 14.4 2 14,000 10,800 60.0 17.3 6.8F1/F2

    83.5 73.4 90 80F3/F4

    EP042 4.8 1 4,800 3,600 20.0 51.9 6.8 - 33.5 30.1 35 35

    EP042 9.6 1 9,600 7,200 40.0 17.3 6.8 - 58.5 51.8 60 60

    EP042 14.4 2 14,400 10,800 60 51.9 6.8F1/F2

    83.5 73.4 90 80F3/F4

    EP048 4.8 1 4,800 3,600 20.0 17.3 6.8 - 33.5 30.1 35 35

    EP048 9.6 1 9,600 7,200 40.0 34.6 6.8 - 58.5 51.8 60 60

    EP048 14.4 2 14,400 10,800 60 51.9 6.8F1/F2

    83.5 73.4 90 80F3/F4

    EP048 19.2 2 19200 14,000 80 69.2 6.8F1/F2

    108.5 95.0 110 100F3/F4

    EP060 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 40 35

    EP060 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60

    EP060 14.4 2 14,400 10,800 60 51.9 9.1F1/F2

    86.4 76.3 90 80F3/F4

    EP060 19.2 2 19,200 14,000 80 69.2 9.1F1/F2

    111.4 97.9 120 100F3/F4

    EP070 4.8 1 4,800 3,600 20.0 17.3 9.1 - 36.4 33.0 35 35

    EP070 9.6 1 9,600 7,200 40.0 34.6 9.1 - 61.4 54.6 70 60

    EP070 14.4 2 14,400 10,800 60 51.9 9.1F1/F2

    86.4 76.3 90 80F3/F4

    EP070 19.2 2 19,200 14,000 80 69.2 9.1F1/F2

    111.4 97.9 120 100F3/F4

    Electric heat is not available for horizontal-straight through airflow configuration. Use a Bosch flanged duct heater in this application. Units with electric heat require dual point power connections. Chart above is for the blower and heater only. Refer to catalog for compressor electrical data.