October 10, 2014 Slide 1: Certification Requirements for Diurnal Fuel Systems on Marine Spark-Ignition Vessels This U.S. Environmental Protection Agency (EPA) tutorial provides an overview of the certification process and requirements for manufacturers to certify marine spark-ignition (SI) diurnal fuel systems used in marine SI vessels. Please use the buttons on your screen to play, pause, or stop the tutorial or access closed captioning. Note that all links referenced in the tutorial are listed at the end of the presentation, where you will be able to click the links and bookmark them. This tutorial provides an overview of EPA compliance and test procedures that are set forth in the Code of Federal Regulations (CFR). This overview does not replace or substitute for the CFR or rules published in the Federal Register. Any representation made in this tutorial counter to the language or intent of the regulations shall be void. Legal statutory and regulatory authority rests in the regulations contained in the CFR. The information in this tutorial is not exclusive of all the requirements under the regulations. Please see the appropriate regulatory sections in the CFR for more detailed and specific instructions relating to your regulatory requirements.

Upload: others

Post on 08-Mar-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

October 10, 2014

Slide 1: Certification Requirements for Diurnal Fuel Systems on Marine Spark-Ignition Vessels

This U.S. Environmental Protection Agency (EPA) tutorial provides an overview of the certification process and requirements for manufacturers to certify marine spark-ignition (SI) diurnal fuel systems used in marine SI vessels. Please use the buttons on your screen to play, pause, or stop the tutorial or access closed captioning. Note that all links referenced in the tutorial are listed at the end of the presentation, where you will be able to click the links and bookmark them. This tutorial provides an overview of EPA compliance and test procedures that are set forth in the Code of Federal Regulations (CFR). This overview does not replace or substitute for the CFR or rules published in the Federal Register. Any representation made in this tutorial counter to the language or intent of the regulations shall be void. Legal statutory and regulatory authority rests in the regulations contained in the CFR. The information in this tutorial is not exclusive of all the requirements under the regulations. Please see the appropriate regulatory sections in the CFR for more detailed and specific instructions relating to your regulatory requirements.

Page 2: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 2

Slide 2: Topics Covered

This tutorial:

• Explains the background and requirements for manufacturers to certify; • Reviews marine spark-ignition (SI) diurnal fuel systems for certification; • Describes the design-based and test-based certification pathways; • Provides an overview on how to submit diurnal certification information in the Central

Data Exchange (CDX) and Verify system; and • Summarizes the certification process.

For additional information on the certification process, CDX/Verify, and related information, please refer to the Helpful Resources section at the end of this tutorial.

Page 3: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 3

Slide 3: Background Certification Information

In order to sell or import non-road engines or vehicles in the United States, a manufacturer must demonstrate compliance to emission standards and obtain a certificate of conformity (referred to as a certificate). To obtain a certificate, a manufacturer must complete the certification process to ensure that their engines or vehicles meet emission standards. EPA has the authority under the Clean Air Act (as specified under 42 U.S.C. 7525) to confirm emissions data submitted by manufacturers through confirmatory testing. EPA may perform confirmatory testing on engines or vehicles at EPA's National Vehicle and Fuel Emissions Laboratory (NVFEL) or at an EPA designated contract test facility.

Page 4: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 4

Slide 4: Manufacturer Certification Requirements

Manufacturer requirements for certification include:

• Establishing an EPA manufacturer code and a Central Data Exchange (CDX) user account; and

• Submitting emissions data and other certification information to the Verify system.

The manufacturer code is a unique identifier directly linked to the certifying company and is used in each emission family name. All manufacturers must establish a CDX user account and obtain an EPA-assigned three-character manufacturer code in CDX. The CDX account is linked to the manufacturer code and allows users access to the Verify system (Verify), which is used to submit electronic information to EPA. Verify collects and processes emission certification and compliance information for EPA review. In the Helpful Resources slide at the end of this tutorial, there is a link to a short tutorial on the CDX account setup process and a link to the CDX Upload Instructions, which provides detailed information on how to submit emissions data and other certification information to Verify.

Page 5: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 5

Slide 5: Marine Spark-Ignition Diurnal Certification

Manufacturers of diurnal fuel systems must undergo the certification process. Manufacturers of diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards. EPA established standards to reduce the amount of diurnal or daily hydrocarbon emissions that escape through a vessel's fuel tank system. The following marine SI fuel tanks require diurnal certification:

1. Portable marine fuel tanks, which o supply fuel to marine engines during operation, and o are not permanently installed on vessels;

AND

2. Installed marine fuel tanks, which o Are installed in personal watercrafts (PWCs) and other marine SI vessels, o Deliver fuel to marine engines, and o Do not fit the definition of portable marine fuel tanks.

Page 6: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 6

Slide 6: Regulations for Marine SI Diurnal Certification

Diurnal certification requirements for marine SI fuel systems are located in the regulations under 40 CFR parts 1045 and 1060. Part 1045 covers spark-ignition propulsion marine engines and vessels and part 1060 covers evaporative emissions from new and in-use non-road and stationary equipment. Electronic versions of EPA regulations can be found under Title 40 at www.ecfr.gov, which is also provided in the Helpful Resources section at the end of this tutorial.

Page 7: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 7

Slide 7: Marine SI Diurnal Standards for Certification

Marine SI portable fuel tanks and installed fuel tanks must meet the diurnal standards specified in 40 CFR 1060.105:

• Portable marine fuel tanks must meet the diurnal design requirements specified in 40 CFR 1060.105 (c)(d) and (f).

• The diurnal emissions standard for installed marine fuel tanks is 0.40 g/gal/day (grams/gallon/day).

• Marine fuel tanks installed in nontrailerable boats (boats that stay in the water during the boating season) have an alternative diurnal emissions standard of 0.16 g/gal/day.

• Manufacturers may demonstrate emission family compliance with diurnal emission standards specified in 40 CFR 1060.105 by using emission control technologies specified in 40 CFR 1060.240 (e).

Page 8: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 8

Slide 8: Pathways to Diurnal Certification

There are two pathways to diurnal certification:

• Design-Based Certification; or • Test-Based (Performance-Based) Certification

Page 9: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 9

Slide 9: What is Design-Based Certification?

Design-based certification allows manufacturers to show or demonstrate compliance without testing the diurnal system. The design-based certification pathway allows manufacturers to certify families that use established technologies already known to comply with applicable diurnal emission standards. Manufacturers choosing design-based certification may submit an engineering description instead of test results in the certification application to support that their diurnal system meets EPA design-based requirements.

Page 10: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 10

Slide 10: Design-Based Certification Requirements

Portable marine fuel tanks must meet the following diurnal requirements as specified in 40 CFR 1060.105 (c) (d) and (f):

• Must be self-sealing when detached from the engine • Must not vent to atmosphere when attached to an engine • Manual vent allowed - to temporarily relieve pressure • Must remain sealed up to positive pressure of 24.5 kilopascals (kPa) or 3.5 pounds per

square inch gauge pressure (psig) • No air outlets that vent to the atmosphere at pressures below 34.5 kPa or 5.0 psig • Detachable fuel lines for use with portable marine fuel tanks must be self-sealing when

not attached to engine or fuel tank • Meet provisions in the American Boat And Yacht Council Materials (ABYC H-25) as

referenced in 40 CFR part 1060.810

Page 11: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 11

Slide 11: Design-Based Certification Requirements

For design-based certification approval, manufacturers may use design-based technology on installed marine SI fuel tanks to demonstrate compliance to diurnal emission standards. There are two options available under diurnal design-based certification. One design-based option is for the marine SI fuel tank to remain sealed up to 1 pound per square inch (psi), or pound per square inch of gauge pressure (psig) with the pressure relief valve set at a value greater than 1.0 psi or psig. The other option is the marine SI fuel tank must be equipped with a passively purged carbon canister that meets the requirements in 40 CFR 1060.240(e)(2).

Page 12: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 12

Slide 12: What is Test-Based Certification?

Test-based certification allows manufacturers to:

• Certify by testing the diurnal system; and • Submit diurnal test data that demonstrates compliance with EPA standards.

Page 13: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 13

Slide 13: Test-Based Certification Requirements

For test-based certification, manufacturers must test fuel systems for diurnal emissions as specified in 40 CFR 1060.525,

• The diurnal test applies to fuel systems with or without carbon canisters; and • Diurnal emissions measurements are based on representative temperature cycles (in

degrees Celsius).

For trailerable boats which are less than 26 feet and are transported or towed by a trailer,

• The fuel temperature range during the diurnal test is 25.6°C (degrees Celsius) to 32.2°C.

For nontrailerable boats (which are 26 feet or more, or have a width of more than 8.5 feet),

• The boats stay in the water throughout boating season; and • The fuel temperature range during the diurnal test is 27.6°C to 30.2°C.

Page 14: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 14

Slide 14: Submitting Diurnal Compliance Documents in Verify

The first step in the certification process is to submit diurnal compliance documents in Verify.

Page 15: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 15

Slide 15: Diurnal Compliance Documents

Required diurnal compliance documents that need to be uploaded to Verify for design-based certification should include:

• A description with a drawing or picture of the design-based diurnal system; and • Sample label language meeting the criteria in 40 CFR 1060.137.

Required documents for test-based certification include:

• The Diurnal Test Data Worksheet, which will be reviewed on the next slide; and • Sample label language meeting the criteria in 40 CFR 1060.137.

An EPA representative may ask for additional information during the certification review.

Page 16: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 16

Slide 16: Diurnal Test Data Worksheet

This is the Diurnal Test Data worksheet. Manufacturers who are seeking test-based certification must complete this worksheet and upload it in Verify. Please enter diurnal data in all applicable fields including:

• Manufacturer; • Emission Family Name; • Test Facility; • Nominal Fuel Tank Capacity (in gallons); • Whether or not the fuel system is equipped with a Canister (Yes or No); • Canister Working Capacity (in grams); • Fuel Temperature Range; and • Stabilization period information (if applicable).

Please complete the bottom table which will calculate the daily diurnal emission measurements and the maximum diurnal emission level. Now we will walk through the process of submitting Diurnal Compliance Documents in Verify as a manufacturer of marine diurnal systems.

Page 17: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 17

Slide 17: Program Services Page

After logging in to CDX, you will arrive on the program services page for Verify, which is currently displayed on your screen. Compliance documents must be submitted to Verify before starting other datasets. There are two methods to upload documents:

• Clicking the "Upload Compliance Documents" link; or • Entering through the "Non-road Spark Ignition" page.

In this training, we will demonstrate the second option. The "Upload Nonroad SI Compliance Documents" link on the Non-road Spark Ignition home page provides users with a streamlined method for uploading compliance documents to Verify. Both methods lead to the same result with the compliance documents being linked to the applicable evaporative family or families. Click the "Non-Road Spark Ignition" link to continue.

Page 18: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 18

Slide 18: Nonroad Spark Ignition Page

Next, click the "Upload Nonroad SI Compliance Documents" link.

Page 19: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 19

Slide 19: Compliance Documents Upload Page

This page is used to submit documents pertaining to general data, specific engine family data, or specific evaporative family data. Use this page to submit your documents related to the diurnal evaporative family data. Complete the required fields, as well as any other applicable fields.

Page 20: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 20

Slide 20: Select Document Type

Please select the correct Document Type you are uploading to Verify. For instance, for the diurnal test data worksheet or designed-based description and drawing, select "Test Data Worksheet" from the menu. For the diurnal sample label, select "Sample Label Language" as the document type. Further down the page, you would click the "Browse" button to locate and attach test data files. You can upload multiple documents at a time and, for larger files, you should create individual ZIP files. When all applicable fields have been completed and the test data has been attached, you would click the "Review & Submit" button to upload the document or documents.

Page 21: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 21

Slide 21: Completing Diurnal Datasets in Verify

The next step in the certification process is to complete diurnal datasets in Verify.

Page 22: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 22

Slide 22: Program Services Page

From the Verify landing page, click the "Non-Road Spark Ignition" link.

Page 23: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 23

Slide 23: Nonroad Spark Ignition Page

Next, click the "Nonroad SI Evaporative Components/Equipment" link.

Page 24: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 24

Slide 24: Evaporative Component Selection

Then click the "Diurnal" link.

Page 25: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 25

Slide 25: Start New Dataset

Click "Start New Dataset" to open the Evaporative Component Submission Form – Diurnal.

Page 26: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 26

Slide 26: Evaporative Family Dataset

You are now on the Evaporative Family dataset and can begin entering information. The Evaporative Family dataset must be completed for design-based and test-based certification. The evaporative family name has 12 characters. The three-character manufacturer code in the evaporative family name is a unique identifier directly linked to the certifying company. The highlighted example is an evaporative family name in which E is the model year, MFR is the manufacturer code, PMDRN means marine diurnal, and XYZ are letters or numbers selected by the manufacturer as a unique identifier for the family name.

Page 27: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 27

Slide 27: Design-Based Certification Description

If you are requesting design-based certification, select "Yes" from the "Design-Based Certification Indicator" drop-down menu. In the "Design Based Certification Description" box displayed on the screen, please specify the marine fuel tank type (portable marine fuel tank, trailerable, or nontrailerable), type in the diurnal family name, and describe how the marine fuel system meets the diurnal design-based certification criteria. If you are placing an abbreviated label on your diurnal system, enter the abbreviated code and the location of the label in the "Design Based Description" field. The manufacturer code may be used in the abbreviated code. For example, a manufacturer may enter: "The abbreviated label EPA-MFR-DRN is on the fuel cap." 1. For portable marine fuel tanks, specify that this is a portable marine fuel tank, type in the

evaporative family name, and describe how the portable marine fuel tank meets the diurnal design-based criteria in the box below.

Page 28: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 28

Please review the example portable marine fuel tank design-based description displayed on the screen.

This portable marine fuel tank family (insert the evaporative family name) meets diurnal requirements in 40 CFR 1060.105 (c) (d), and (f). The tank: 1) is self-sealing when detached from the engine; 2) has a manually activated device that temporarily relieves pressure; 3) remains sealed up to a positive pressure of 24.5 kPa (3.5 psig); 4) does not vent at pressures below 34.5 kPa (5.0 psig); and 5) meets the provisions of ABYC H-25. The abbreviated label EPA-MFR-DRN is on the fuel tank or cap.

2. For installed marine fuel tanks (permanently installed in trailerable and nontrailerable vessels), describe how the diurnal system fuel tank or canister installed in marine vessels meets the design-based criteria in the box below.

Please review the example fuel tank design-based description displayed on the screen.

This trailerable or nontrailerable diurnal family (insert the evaporative family name) meets regulations 40 CFR 1060.240(e)(1) of design-based technology for diurnal emissions requirements. The fuel tank remains sealed up to a positive pressure of up to 1.0 psig. The pressure relief valve is set at a value greater than 1.0 psig. The abbreviated label EPA-MFR-DRN is on the fuel tank or cap.

Now review the example canister design-based description displayed on the screen. :

This trailerable or nontrailerable diurnal family (insert the evaporative family name) meets regulations 40 CFR 1060.240(e)(2) of design-based technology for diurnal emissions requirements. The passive-purge carbon canister has carbon that meets the requirements in 40 CFR 1060.240(e)(2). The abbreviated label EPA-MFR-DRN is on the fuel tank or cap.

Test information is not required for design-based certification.

Page 29: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 29

Slide 28: Test Information Dataset

The "Test Information" dataset is required for test-based certification. Click the "Test Information" tab to continue.

Page 30: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 30

Slide 29: Enter Test Data

Enter test data in the fields on the "Test Information" dataset. You can use the same information provided in the Diurnal Test Data worksheet.

Page 31: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 31

Slide 30: Additional Information

Further down the page, enter any additional information on the diurnal system in the "Manufacturer Evaporative Family Comments" field. If you are placing an abbreviated label on your diurnal system, enter the abbreviated code and the location of the label in the "Manufacturer Evaporative Family Comments" field. The manufacturer code may be used in the abbreviated code. For example, a manufacturer may enter: "The abbreviated label EPA-MFR-DRN is on the fuel cap." Now we will move on to submitting a request for a certificate.

Page 32: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 32

Slide 31: Submitting Request for Certificate Dataset in Verify

The final step in completing the certification process in Verify is to request a certificate in the "Request for Certificate" dataset. The "Request for Certificate" dataset cannot be submitted until after the compliance documents and the diurnal datasets have been submitted to and accepted by Verify.

Page 33: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 33

Slide 32: Nonroad Spark Ignition Page

From the Nonroad Spark Ignition menu, click the "Request for Certificate" link.

Page 34: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 34

Slide 33: Request for Certificate

Next, click the "Evaporative (including equipment/vessel certification)" link.

Page 35: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 35

Slide 34: Start New Dataset

Then click "Start New Dataset".

Page 36: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 36

Slide 35: Request for Certificate Dataset

Complete all required and applicable fields in the "Request a Certificate" dataset. After correctly completing the fields and submitting the dataset, the manufacturer's diurnal application is placed in the certification queue for EPA review.

Page 37: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 37

Slide 36: Summary

In summary, manufacturers of marine SI diurnal fuel systems must:

• Obtain a certificate of conformity; • Set up a CDX account and a manufacturer code to access Verify; • Meet design-based or test-based certification requirements; and • Submit required data to Verify in order to certify.

Page 38: EPA Certification Requirements for Diurnal Fuel Systems on ... … · diurnal fuel systems must certify that their fuel tanks intended for use in marine SI vessels meet diurnal standards

EPA Diurnal Fuel Systems on Marine Spark-Ignition Vessels October 10, 2014 Page 38

Slide 37: Helpful Resources

Shown on your screen is a list of resources discussed in this tutorial, along with additional related information. Clicking on any of the links will open the selected page in a new window. • Electronic Code of Federal Regulations • Gasoline Boats and Personal Watercraft website • Diurnal Emission Requirements for Marine Spark-Ignition Vessels Tutorial • Verify Engine and Vehicle Compliance Information System • Manufacturer Code Setup • Verify Information System Documents, Guidance and Requirements • Verify Information and CDX Account Setup • CDX Account Setup Tutorial • CDX website • CDX Upload Instructions • Engine and Vehicle Certification Templates • OTAQ Document Index System (DIS) This concludes the tutorial on Certification Requirements for Diurnal Fuel Systems on Marine Spark-Ignition Vessels.