epoxy breakout test: pull out test astm 4435 centrale à damas... · building s ystems, p.o. box:...
TRANSCRIPT
Building Systems, P.O. Box: 34831 : . 34831 ,
36(1) Abu Bakr Al-Siddiq Street Damascus – Syria 36(1 - )
Phone: +963-11-2128331 / Fax: +963-11-2112604 : 2112604-11-963+ / : 2128331-11-963+
Email: [email protected] :
Epoxy Breakout test: Pull out Test ASTM 4435
Project : Central Bank- New building.
Contractor : Mili House responsible : Eng. Abdulkarim Eisha
Consultant : Halcrow Groupe Ltd. responsible : Eng. Abdulkader Habra
Date of the test : Dec. 13.2011
1- Materials used to make the test:
- pump Enerpac, 25 ton.
-Piston Enerpac Model RCH 202, 20 ton.
2- Epoxy Types:
- EA : Stahlfix Epoxy acrylate
- EASF : Stahlfix Epoxy acrylate styrene free
*- VESF : Stahlfix Pure vinyl ester styrene free
3- Calculating Loads:
Pressure : 1 bar = 100 KN/m2
Piston surface : = 30.5 c m2
Load = ( ) x 30.5 c m2 = ……R (KN)= ……R/10 (Ton)
Building Systems, P.O. Box: 34831 : . 34831 ,
36(1) Abu Bakr Al-Siddiq Street Damascus – Syria 36(1 - )
Phone: +963-11-2128331 / Fax: +963-11-2112604 : 2112604-11-963+ / : 2128331-11-963+
Email: [email protected] :
4- Breakout Models:
5- Support: Al Mothallath Group.
6- Results:
No. Bar
(mm)
Hole
(mm)
Depth
(mm)
Epoxy type Pressure
Bar
Load
Ton
Breaking down Type
a b c
1 12 14 110 VESF 250 7.625 *
2 12 14 110 VESF 250 7.625 *
3 12 14 110 VESF 240 7.32 *
7–Remarks: The rods were fixed at 12 pm on 11.12.2011. The tension test was performed
after 48 hours exposing the rods to frost degrees during the night.
Company: Mili House Consultant: Halcrow Groupe Ltd.
لثانياالخـتـبـار ا االخـتـبـار األول
لثالثاالخـتـبـار ا