ericsson counters for codecs

3
2.3.1 Statistics and Traffic Measurement, Object Type BSCSTAT 2.3.1.1 Command Parameters Parameter Description OBJTYPE Object type name BSCSTAT Object type for BSC level statistics Counters are stored for each BSC in the Mobile services Switching Centre (MSC)/Visitor Location Register (VLR) Server. OBJ Object name BSC name or ALL Text string 1 - 7 characters FMULA Formula The formula includes a single counter or a mathematical expression involving the counters belonging to the object type, expressed in reverse polish notation. Possible counters are listed under Section 2.3.1.2 Text string 1 - 78 characters 2.3.1.2 Counters The following counters can be addressed in parameter FMULA: Counter Description NBSDFRFRSUCC Number of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual Full-Rate (FR) and FR assigned NBSDFRHRSUCC Number of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual FR and Half-Rate (HR) assigned NBSDFRSUCC Number of successful initial channel assignments with channel

Upload: yayra-de-souza

Post on 26-Dec-2015

25 views

Category:

Documents


4 download

DESCRIPTION

The object type BSCSTAT shows the codec usage on the Ericsson MGW

TRANSCRIPT

Page 1: Ericsson counters for codecs

2.3.1   Statistics and Traffic Measurement, Object Type BSCSTAT

2.3.1.1   Command Parameters

Parameter Description

OBJTYPE Object type name

BSCSTAT

Object type for BSC level statistics

Counters are stored for each BSC in the Mobile services Switching Centre (MSC)/Visitor Location Register (VLR) Server.

OBJ Object name

BSC name or ALL

Text string 1 - 7 charactersFMULA Formula

The formula includes a single counter or a mathematical expression involving the counters belonging to the object type, expressed in reverse

polish notation. Possible counters are listed under Section 2.3.1.2

Text string 1 - 78 characters

2.3.1.2   Counters

The following counters can be addressed in parameter FMULA:

Counter Description

NBSDFRFRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual Full-Rate (FR) and FR assigned

NBSDFRHRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual FR and Half-Rate (HR) assigned

NBSDFRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual without preference and FR assigned

NBSDFRTOTNumber of initial channel assignments with channel rate and type in Assignment Request message equal to dual FR

NBSDHRFRSUCC Number of successful initial channel assignments with channel rate and

Page 2: Ericsson counters for codecs

type in Assignment Request equal to dual HR and FR assigned

NBSDHRHRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual HR and HR assigned

NBSDHRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to dual without preference and HR assigned

NBSDHRTOTNumber of initial channel assignments with channel rate and type in Assignment Request message equal to dual HR

NBSDTOTNumber of initial channel assignments with channel rate and type in Assignment Request message equal to dual without preference

NBSFRFRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to FR

NBSFRTOTNumber of initial channel assignments with channel rate and type in Assignment Request message equal to FR

NBSHRHRSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message equal to HR

NBSHRTOTNumber of initial channel assignments with channel rate and type in Assignment Request message equal to HR

NBSMSLSUCCNumber of successful initial channel assignments with channel rate and type in Assignment Request message in a multi-slot configuration

NBSMSLTOTNumber of initial channel assignments with channel rate and type in Assignment Request message in a multi-slot configuration

NBSPCHACMTOTNumber of A-interface circuit pool number mismatches at channel assignment completion or handover completion

The counter is increased for all Assignment Complete and Handover Request Acknowledge messages received as a result of circuit pool mismatch.

NBSPCHAFMTOTNumber of channel assignment failures or handover failures due to A-interface circuit pool mismatch

The counter is increased for all Assignment Failure and Handover Failure messages received due to circuit pool mismatch.

NBSPCHAFSWTOTNumber of channel assignment failures or handover failures due to switch of A-interface circuit pool

The counter is increased for all Assignment Failure and Handover Failure messages received due to switch of A-interface circuit pool.

Page 3: Ericsson counters for codecs