esp suface choke - sercel-grc.com · all wiring and repair shown in this manual must be performed...

11
A NYWHERE . A NYTIME . E VERYTIME. FIELD INSTALLATION MANUAL ESP SUFACE CHOKE

Upload: duongkhanh

Post on 16-Aug-2019

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

A N Y W H E R E . A N Y T I M E . E V E R Y T I M E .

FIELD INSTALLATIONMANUAL

ESP SUFACE CHOKE

Page 2: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Document: 006-0213-00 Rev A Page 2 of 10

NOTICE

This manual is intended for private information only, with the understanding that any other use of the subject matter, in whole or in part, by reference or otherwise, shall be only with the prior knowledge and approval of Sercel-GRC Corp, and with the further understanding that this manual is for informational purposes only and that suggestions and recommendations contained herein shall not be understood or construed as a guarantee or warranty of any method, product or device. Federal copyright law protects the publication. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Sercel GRC Corp. Any questions concerning the content of this manual, equipment operation, field maintenance, maintenance assistance and operation or maintenance training courses should be directed to Sercel-GRC.

Copyright © 2014 by Sercel-GRC Corp. All rights reserved worldwide.

Document Number: 006-0213-00

Sercel-GRC Corp.

6540 East Apache Street, Tulsa, Oklahoma 74115-3616 USA P.O. Box 581570 Tulsa, Oklahoma 74158-1570 USA

E-Mail: [email protected] or [email protected] Telephone: (1) 918-834-9600 / Fax: (1) 918-838-8846

Visit our web page at www.sercel-grc.com

Page 3: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Document: 006-0213-00 Rev A Page 3 of 10

Table of Contents

Sercel GRC Replacement Part Numbers .................................................................... 3

Surface Interface and Protection ................................................................................. 4

Surface Choke ............................................................................................................. 5

Surge Panel Protector ................................................................................................. 7

Motor/ Fuse Interface Panel ........................................................................................ 8

Surface Choke and Surge Panel Wiring Diagram ........................................................ 9

Before Installation Checks ......................................................................................... 10

Sercel GRC Replacement Part Numbers

043-0029-00 5000 VAC 1/2A Replacement Fuse 90A2180 Motor Phase Resistor Assembly 1K Ohm 7W 90A2181 Surge Suppressor Resistor Assembly 82K Ohm 2W 90A2182 Surge Suppressor MOV Assembly 90A2183 Surge Suppressor Filter Capacitor Assembly 5uF 600V (w/cable ties) 90B2175 ESP Choke Assembly 90C2215 Surge Suppressor Assembly 99B990 3 Phase Choke

! Danger ! ! High voltages present with

risk of electric shock !

All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution

when working on equipment. Never perform maintenance on powered equipment.

Page 4: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 4 of 10

Surface Interface and Protection

ESP Gauge Surface Interface Equipment connects to the downhole tool via the motor power cable. The Motor Power cable connects to the equipment via the Surface Choke. Communication and Power are provided via a “Coms-on” technique meaning that the communication and power is combined with the motor power. “Coms-on” power is provided to the ESP Gauge by the ESP Interface Surface Equipment. The ESP Interface Surface Equipment is connected to the ESP Surge Protection Equipment via the Gauge Signal and Ground wire. There are two options for ESP Surge Protection Equipment. See following information below for descriptions of the Surface Choke, Surge Panel, and Surface Choke Assembly.

Page 5: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 5 of 10

Figure 1. ESP Surface Choke Assembly 90B2175.

Surface Choke

The surface choke is connected between the VSD 3-phase power and the Surge Panel or Surge Protector. The purpose of the surface choke is to allow the ESP Gauge Interface to provide power to and communicate with the downhole tool. The ESP Gauge Interface provides between 30-80VDC to the Neutral wire on the Surface Choke

SURGE SUPPRESSOR ASSEMBLY

3 Phase Surface Choke

High Voltage Phase Protection Assembly

Page 6: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 6 of 10

to power the downhole gauge. The Surface Choke is designed to provide a neutral point “WYE point” for direct connection of power and communication on the three phase cable. The Choke also adds low pass filtering to protect sensitive electronic equipment from damaging voltage transients.

Figure 2. 3 Phase Surface Choke.

Figure 3. 3 Phase Surface Choke Wiring Diagram.

Neutral / WYE

3 Phase Motor Power Connection

A1, B1, C1

Choke Chassis

Ground

Page 7: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 7 of 10

Surge Panel Protector

The Surge Panel provides protection for the ESP Surface Interface equipment from several failures including; overvoltage from imbalance, transient voltage pulses, and electro static discharge.

Figure 4. Surge Panel Component Detail.

Figure 5. Surge Panel Protector Schematic and Connections

Surge Panel Contacts

1 N/C

2 Gauge Signal +

3 N/C

4 Choke Neutral

5 N/C

6 Gauge Signal GND

7 Dedicated Well GND

8 N/C

From Surface Choke WYE/ Neutral Wire

Dedicated Well Ground

Replaceable MOV Protection Device

Voltage Drain Resistor

1/2A High Voltage WYE point Protection Fuse

Filter Capacitor

Page 8: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 8 of 10

Motor/ Fuse Interface Panel

The Motor/ Fuse interface panel contains protection fuses for each phase connecting to the Surface Choke and the terminal block for connecting the motor to the Surface Choke. Each leg is protected with a replaceable 1/2A High Voltage fuse and 1K Ohm Power Resistor. The resistors filter low frequency DC voltage signals while the motor drive output frequency is ramping up.

Figure 6. Motor/ Fuse Interface Panel Detail.

#4 Phase B Terminal

#2 Phase A Terminal

#6 Phase C Terminal

High Voltage Fuse 1/2A x3

Filtering Power Resistor x3

Page 9: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 9 of 10

Surface Choke and Surge Panel Wiring Diagram

Figure 7. Surge Panel Wiring Diagram

Surface Interface Connection to Scout or SPS-1500 Red – Gauge Signal Black – Gauge Ground

Motor Wire Connection Phase A, B, C Well Head/Earth Ground Shown in Figure 8.

Earth GND (Figure 8)

Well GND (Figure 8)

Page 10: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Doc No. 006-0213-00 Rev A Page 10 of 10

Figure 8. Detailed Wiring Connections.

Before Installation Checks

The interface between the ESP Gauge and a surface readout device (Scout or SPS) is composed of two parts. The first part is the high-voltage 3-phase choke that connects to the motor power cable. The second part is the fuse block/surge suppressor between the choke and the Scout/SPS. A visual inspection should check for the following:

Verify that the wiring on the fuse block assembly and the 3-phase choke are correct and have not been damaged.

Verify that the 0.5A high-voltage fuses on the fuse block assembly and surge suppressor are not open circuits.

Verify that the MOV on the surge suppressor assembly has not been damaged. A resistance check on the MOV should read open (> 1Mohm) when the MOV is removed from the circuit. Low resistance or a broken MOV indicates the MOV must be replaced. Do not operate the unit without the MOVs in place. Check the three-phase choke with a meter by measuring the resistance between each of the three phases and the neutral lead that connects to the fuse block. It should measure around 130 ohms. Field Tips:

Make sure that the Surface Choke wires that are connected to the transformer are braided.

If longer cable is needed from the Transformer to the Surface Choke, make sure that it is rated for the Transformer voltage.

Contact Sercel-GRC Customer Service for any additional information.

#2 Gauge Signal (+)

#4 WYE Wire Factory Installed

#6 Gauge Signal (GND)

3 Phase Choke Chassis Ground

#7 Dedicated Well Ground

Label Indicates Mounting Hole Cleared of Insulation Coating. Older Models Do Not Have a Clean Choke Chassis Ground.

Page 11: ESP SUFACE CHOKE - sercel-grc.com · All wiring and repair shown in this manual must be performed by qualified personnel. Always use proper PPE and use caution when working on equipment

Sercel-GRC Corp.

6540 East Apache St

Tulsa, OK 74115-3616 USA

Telephone: +1.918.834.9600

Fax: +1.918.838.8846

Email: [email protected]

www.Sercel-GRC.com

Printed in the USA. © Sercel-GRC Corp.

Sercel-GRC Corp. is a worldwide leader in downhole data

acquisition and the leader in proprietary technology for

measuring, recording and delivering reliable and accurate

well data with extremely high resolutions.

Sercel-GRC provides gauges and surface readout tools

for permanent, memory, mechanical and artificial lift

applications and is the manufacturer of the Amerada®

mechanical gauge used for over 80 years in the oil and

gas industry.

For more information on this product or any of the qual-

ity monitoring and data acqusition solutions Sercel-GRC

offers, contact us.

SM

Anywhere. Anytime. Everytime.

Ahead of the Curve