ess & micro-grid brochure
TRANSCRIPT
en.hopewind.comen.hopewind.com 0302
Shenzhen Hopewind Electric Co., Ltd. (Stock Code: 603063) focuses on the research, manufacture, sales and service
of renewable energy & electric drive products, with main products of wind power generation products, photovoltaic
generation products, power conversion products, industrial drive products and electric car products. Furthermore,
Hopewind owns independent development & testing platforms of integrated high-power power electric equipment
and monitoring system. Through innovation in technology and service, Hopewind continuously creates value for
customers, and has become one of the most competitive enterprises in renewable energy field.
In the field of power conversion system, Hopewind provides competitive common AC/DC PCS overall solutions,
including power conversion system (PCS), energy management system (EMS) and overall energy store system.
Relative PCS products have obtained the certification and test reports from CGC, TUV-SUD, CEPRI HLVRT (including
ZVRT) and so on.
>> About Hopewind
All-in-one Energy Storage System Solution - C&I Industry
Overview of Energy Store System Application
Cabinet Type - AC/DC Bi-directional PCS
Outdoor Wall-mounted Type - AC/DC Bi-directional PCS
Multi-machine Parallel Control Cabinet
Energy Management System
System Integration
Project Cases
04
06
08
10
12
13
14
15
Headquarter and R&D Base: ShenzhenManufactures & factories: Shenzhen, Suzhou, Dongguan, YanchengServices Partner: Russia, Vietnam, Brazil, Korea, Turkey, Ukraine, Pakistan, MalaysiaSales & Service Center: Beijing, Shanghai, Russia
ISO9001: 2015 ISO14001: 2004 OHSAS 18001: 2007
【Quality System】
【Honors】
Laboratory Qualification Approved by CNAS
National High-tech EnterprisesNational Science and Technology Progress Award
en.hopewind.comen.hopewind.com 0504
>> All-in-one Energy Storage System Solution- C&I Industry
Features Specifications
Product Principle
Model hopeQESS
Battery Data
Cell type LFP 3.2V/280Ah
Configuration of system 16S1P*13
Battery capacity (BOL) 186kWh
Battery voltage range 582.4V~748.8V
BMS communication interfaces 485
BMS communication protocols Modbus RTU
AC Data
Nominal AC power 80kW
Max. AC power 96kW
Max.THD of current <3% (at nominal power)
DC component <0.5% (at nominal power)
Nominal grid voltage 400V
Grid voltage range 360 ~ 440V
Power factor >0.99 (at nominal power)
Adjustable power factor -1~1
Nominal grid frequency 50Hz
Grid frequency range 45~55Hz
Isolation method Transformer optional
Nominal output voltage of off-grid 400V
Max.THD of off-grid output voltage < 3% (linear load)
Mechanical DataDimensions (W*H*D ) 1250*2030*1650
Weight (with / without battery) 2300kg
General Data
Degree of protection IP54
Operating temperature range -10 to 40°C
Relative humidity 0 ~ 95% (non-condensing)
Max. working altitude 2000m
Cooling concept of battery chamber Ventilation and Air Conditioning
Communication interfaces Ethernet
Communication protocols Modbus TCP
AC Contactor
AC SPD
Power Module
DC SwitchBAT+
BAT-
PE
Grid
Common Filter
Battery
DC Fuse
DC Contactor LC Filter
All-in-one solution for your C&I on-grid industry
IP54 Protectionand exquisite design for bussiness industry
Integration makes optimal system performance and lower cost
User friendly - Improve the equipment installation&maintenance
Modular LiFePO4 battery. flexible configuration
Integration and Flexibility
Low noise, lower than 60dB, friendly to user
Intelligent monitoring and faults record ensures faults location
Friendly and Smart
Support multi-machine direct parallel in AC side
Long-term overload operation with 1.2Pn, 1.4Pn overload in 60s
when operating off-grid with resistive load
Safty and Robustness
en.hopewind.comen.hopewind.com 0706
By adding the energy storage system in the power grid, it can realize peak load shifting, frequency and peak adjustment,
smooth the power generation and user side's energy as well as improve the quality of the power grid.
Specifically including:
1. Realize primary frequency modulation and secondary frequency modulation control, monitor load fluctuations in real time,
respond quickly to grid dispatching, improve grid frequency stability, and improve grid quality.
2. Improve the instability of the output power of wind power/photovoltaic power stations, especially the impact of transient
power on the power grid, thereby improving the power quality of new energy power stations and power grids.
3. Reduce the fluctuation instability of the user side power, smooth the power, improve the efficiency of user side energy, and
reduce the transformer capacity and the basic electricity cost of the user side.
4. According to the difference between the peak and lowest electricity prices, the PCS charges when the electricity price is low,
and discharges when the electricity price is high to obtain certain economic benefits.
>> Overview of Energy Storage System Application
Grid side, Generator side, User Side
The energy storage system includes an energy storage battery, a power conversion system (PCS), an energy management
system (EMS), and a battery management system (BMS).
Energy Storage System Block Diagram
The energy storage system can be combined with new energy power generation system (such as wind power and photovoltaic
power) and diesel generator system to form an off-grid or micro-grid system to solve the electricity demand of users in islands or
remote areas of power grids with unstable power supply. In the micro-grid system, the PCS needs to operate off-grid. For some
special load, the STS devices are required, which can realize automatic switching during the power failure and power restoration.
Off-grid/Micro-grid Application
In the above micro-grid system,
1. Select the capacity of the PCS according to the required power of the load. If the power of the load is large and multiple PCSs are
needed for expansion, the parallel control cabinet is required.
2. The isolation transformer can be placed independently on the outside or built in the PCS.
3. The off-grid PCS is used as a voltage source, and the constant AC output voltage is applied to the load PCS to absorbs energy from
the PV, and the excess is charged into the energy storage battery.
(1) When the power of the PV input port of the PCS is less than the AC output power, the energy storage battery begins to discharge;
(2) When the energy storage battery is discharged to a certain extent and may be difficult to support the load, the diesel is turned on,
and the PCS is switched from the off-grid operation to the simultaneous connection with the generator;
(3) When the power of the PV input is increased to above the load power, the diesel is turned off, and the PCS is automatically
switched to the off-grid operation.
PV Input
PV Input N#PV Combiner Box
1#PV Combiner Box
Energy Storage Battery Load
Grid
Diesel Generator
PV Inverter
PCS
Parallel Control
AC Cable
DC Cable
Comm. Cable
PV Input
en.hopewind.comen.hopewind.com 0908
>> Cabinet Type - AC/DC Bi-directional PCS
Certified by national standard, the max. efficiency is 99%.
Support power factor full range adjustment.
Support a variety of functions including off-grid, multi-machine
direct parallel, VSG, seamless switching on-grid and off-grid.
Support long-term operation with 1.1 times overload and short-
term operation with 1.2 times overload.
The time of switching charge mode and discharge mode is less
than 80ms, and the time of power corresponding is less than
60ms.
Features Specifications
Product Principle
Model hopePCS0300 hopePCS0500 hopePCS0630
DC Side ParametersDC Voltage Range 620V~850V 500V~850V 620V~850V
Max. DC Current 635A 1130A 1147A
AC Side Parameters
Charging and
Discharging on grid Mode
Rated Output Power 300kW 500kW 630kW
Max. Output Power 330kW 550kW 693kW
Rated Output Current 433A 902A 909A
Max. Output Current 476A 992A 1000A
Rated Grid Voltage 400V 320V 400V
Operating Voltage Range 320V~440V 256V~352V 320V~440V
Rated Grid Frequency 50Hz / 60Hz
Operating Frequency Range ±3Hz
THDi <3% (Rated Power)
DC Current Component <0.5% (Rated Output Current)
Power Factor 0.9 (inductive) ~ 0.9 (capacitive)
Off-grid Mode
Rated Output Power 300kW 500kW 630kW
Rated Output Voltage 400V 320V 400V
Rated Output Current 433A 902A 909A
Voltage Fluctuation Range <10%, linear load, 100% change
Output Voltage Distortion <3%, linear load
Rated Grid Frequency 50Hz / 60Hz
Voltage Regulation Accuracy <1%
System Parameters
Max. Efficiency 98.8% 98.9% 99.0DS%
Isolation Transformer with without
Standby Power Consumption <50W
Cooling Method Forced air cooling
Protection Level IP20
Operating Temperature Range -40℃ ~ +55℃ (Operation with derating above 40℃)
Storage Temperature Range -40℃~+70℃
Operating Altitude ① ≤6000m (Operation with derating above 2000m)
Relative Humidity 0% ~ 95%, no condensation
Communication RS485, Ethernet, CAN
Mechanical ParametersDimensions (W*H*D) (mm) ② 1020*2100*600 1000*2150*800
Weight (kg) <750 <1000
① Please contact HOPEWIND for application over 2000m altitude. ② Dimension excludes screws, locks, etc.
DC SPD
AC Contactor AC Switch
AC SPD
Power Module
LC FilterDC Switch
BAT+
BAT-
PE
PE
Grid
AC Fuse
Battery
DC Fuse D C
en.hopewind.comen.hopewind.com 1110
IP65 protection level, suitable for coastal areas with frequent typhoons.
Reduce direct parallel of battery, to lower the capacity difference
between battery strings years later.
Each group operating independently. Improve the equipment utilization
during maintenance, only the battery group under maintenance needs
to be powered off.
Low noise, lower than 60dB, friendly to user.
Can be installed full manually, special equipments such as forklift and
crane are not required.
Provide dedicated testing equipment to measure leakage current, to ensure the safety of system and
person.
Support multi-machine direct parallel in AC side.
Some models support long-term operation with 1.25 times overload, and operation with 1.4 times overload
in 60s when operating off-grid with resistive load.
Features
>> Outdoor Wall-mounted Type - AC/DC Bi-directional PCS
Product Principle
Specifications
Model hopePCS050 hopePCS060 hopePCS080
DC
Max. DC Power 61kW 73kW 114kW
Max.DC Volatge 900V
Max. DC Current 102A 122A 190A
DC Voltage Range Gird voltage*1.45 ~ 900V
DC voltage Ripple % 2%
AC
Rated Power 50kW 60kW 80kW
Max. Power 60kW 72kW 112kW
AC Connection M8 screw
Isolation No isolation
Q range 0~50 kvar 0~60 kvar 0~80 kvar
On-Grid
Rated Grid Voltage 440V
Grid Voltage Range 304V ~ 440V
Rated Grid Frequency 50Hz / 60Hz
Frequency range 47Hz ~ 53Hz / 57Hz ~ 63Hz
THD 3%
Power Factor -1 ~ 1
Switching T charge/discharge 60ms
Off-Grid
Rated Output Voltage 400V
Voltage Deviation ±2%
Voltage Unbalance 2%,Short time < 4%
THDu 3% (Without Load or resistive load )
Rated Output Frequency 50Hz
voltage transient range 10% (Load increases from 20% to 100%/decreases from 100% to 20% ( resistive/balanced load conditions)decrease from 100% to 20% in a short time)
Over-voltage Value Optional
Under-voltage Value Optional
Mechanical
Max. Efficiency 97.8% 98% 98.5%
Operation Temperature -40℃~+60℃
Operation Humidity 0%~100%
Noise 59dB
W*D*H 800*330*668mm
Weight <60kg
IP Protection IP65
Cooling Method Smart cooling
Insulation Resistance 1MΩ
Com
Interface Ethernet, 485
UI Interface LED display: charge/discharge, shutdown, standby, fault
Protocol modbus TCP / RTU
AC Contactor
AC SPD
Power Module
DC SwitchBAT+
BAT-
PE
Grid
Common Filter
Battery
DC Fuse
DC Contactor LC Filter
en.hopewind.comen.hopewind.com 1312
>> Multi-machine Parallel Control Cabinet
When more than 3 PCSs are operating in parallel in the same system, it is necessary to add the multi-machine parallel control
cabinet for unified coordination. A grid-connected control cabinet is designed to support up to 20 PCSs in parallel.
If the PCSs need to realize automatic on-grid/off-grid seamless switch at the same time, the STS control cabinet must be added,
and the parallel control cabinet and the STS cabinet can be integrated.
Synchronization with PCS, free from external interference, high signal stability.
Each PCS is independent, and one or more of them are accidental shutdown or power failure
maintenance, which does not affect the normal operation of other PCSs.
Fiber optic control, high communication speed and fast response.
Easy to add auxiliary function, can expand voltage detection and current detection modules as needed.
Rich interface resources, supporting up to 20 PCSs in parallel.
Simultaneously take power from AC and DC, the system is stable and reliable.
Features (Interface Description)
Product Principle
1#Transformer
PCS1-1
Parallel Control and STS Cabinet
2#Transformer
PCS1-2 PCS2-3 PCS2-4 PCS2-- PCS2-20
Comm. Cable
>> Energy Management System
Micro-grid energy management system (EMS) is in charge of the device status monitoring, energy management, statistical
report and other functions of the whole micro-grid system. The EMS is consisting of the micro-grid central controller (MGCC)
and the EMS server. The MGCC communicate with the energy store system, PV inverter system, diesel generator system and load
power supply system devices in the micro-grid under control, to obtain the real-time status of each system devices, manage
the energy of the devices according to energy management strategy, and issue the device starting/stopping command and
power setting command. As the host of MGCC, the EMS server monitoring the MGCC and devices status, to realize parameter
management, user management, statistical report functions; in the same time, the EMS server communicate with the higher
level host or grid dispatch system, to respond the dispatch of higher level energy management system.
Features
Support multiple OSs such as Windows and Linux, which can ensure the safety of power station control and
data.
The system is structured. The MGCC is in charge of short-term energy management strategy and device
communication. The EMS server is in charge of long-term energy management strategy.
Flexible configuration of system software and hardware, make the system stable and reliable. Can
configure fast and flexibly according to the actual project in a short deployment period.
Advanced and stable energy management strategy, which can maximum the use of the PV energy in the
system and the charging/discharging ability of stored energy; the switching of on-grid/off grid is quick and
the transition is stable.
Load management can optimize the load of system, to ensure the emergency power supply of system
never interrupts.
Friendly and intuitive monitoring software, which can display the status and faults of the devices in the
system intuitively.
Open system communication interface, which can be compatible with multiple devices using different
communication protocols from different manufacturer.
en.hopewind.comen.hopewind.com 1514
Features
System integration design is customized.
For container scheme, the size and functions (such
as on-grid, off-grid and seamless switching) is
customizable.
The battery specification and capacity can be
customized according to requirement.
Manhole
EMS
DC cablesconnecting inlets
PCS
H V
transformer
L V
transformer
Direction C
Direction B
Direction DFlush with the floorFlat plate
Direction A
High Voltage Cabinet
Low Voltage Cabinet
Manhole cover
>> System Integration
> Thermal Power Station Energy Storage Joint FM Project A, Changzhi 15MW/7.5MWh
> Grid-side Energy Storage Project, Henan 24MW/48MWh
> User-side Energy Storage Project B, Zhenjiang 20MW/200MWh
> U s e r - s i d e E n e r g y St o ra g e P r o j e c t , Guangzhou 6MW/50MWh
> User-side Energy Storage Project C, Zhenjiang 5MW/40MWh
> User-side Energy Storage Project, Beijing 1MW/8MWh
> User-side Energy Storage Project, Zhenjiang A 6MW/48MWh
> Thermal Power Station Energy Storage Joint FM Project B, Changzhi 9MW/4.5MWh
>> Project Cases
en.hopewind.com16
> Energy Storage and UPS Combined Project, Zhenjiang 800kW
> U s e r - s i d e E n e r g y St o ra g e P r o j e c t . Changzhou 250MW/1MWh
> PV Power Station Energy Storage Project, Burjan, Russia 4MW/8MWh
> Airport Energy Storage Power Station Project, Beijing 500MW/1.1MWh
> New Energy Power Generation Assorted Energy Storage Project, Korea 12MW/36MWh
> PV Power Station Energy Storage Mirco-grid Project
> User-side Energy Storage Project, Suzhou 250MW/1MWh
> Super Capacitor Energy Storage Project 800kW
禾望电气官方微信Hopewind Website
2021: hopewindAll rights reserved V4.1.1c
If there is any change in product size and parameters, they shall be subject to the latest actual product Hopewind Website
All rights reserved V4.1.1
B u i l d i n g 1 1, G u a n l o n g N o. 2 I n d u s t r y Pa r k , X i l i Town, Nanshan Distr ict , Shenzhen, China, 518055 Tel: +86-755-86026786, Shenzhen (Headquarters)
www.hopewind.com
+86-10-82193180, Beijing (Office) 400-8828-705, Hotline