estimating/take-off and ordering guide - …€¦ · · 2015-10-26estimating/take-off and...
TRANSCRIPT
ESTIMATING/TAKE-OFFAND ORDERING GUIDE
1600 WALL SYSTEM 2®
©KAWNEER COMPANY, INC., 2006162-904 (16 Pages) E.C.#95449-095 (09/09/13)
---------------------------10
90° OUTSIDE CORNERS90° INSIDE CORNER -------------------------------
9ANCHOR CHARTS ----------------------------------
PAGE
6,753,4
INDEX
PARTS IDENTIFICATIONMATERIAL TAKE-OFFPERIMETER DETAILS
2
-----------------------------------------------------------------------------------------
-----------------12,13
1600 GLASSVENT APPLICATION
11ENTRANCE DETAILS -------------------------------
14
1600 WALL SYSTEM 2®
------------------------------MID ANCHOR DETAIL 15
8INTERMEDIATES ------------------------------------
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-096 (10/01/13)
INTERMEDIATES W/ FIBERGLASS----------------------------------PRESSURE PLATE 16
3
5-1/4"
3-3/4"
5-1/4"Lightweight
162-090
162-095
162-003
1" FRAMINGExtrusion # DescriptionProfile
3-3/4"Lightweight162-001
162-091 5-1/4"
3-3/4"162-094
162-027
162-028
5-1/4"
3-3/4"
5-1/4"Lightweight
162-092
162-097
162-015
1/4" FRAMINGExtrusion # DescriptionProfile
3-3/4"Lightweight162-013
162-093 5-1/4"
3-3/4"162-096
162-029
162-019
162-025 162-030
162-026 162-031
S.S.G. VERTICAL MULLIONExtrusion # DescriptionProfile
GLAZING ADAPTERSExtrusion # DescriptionProfile
162-203
162-204
3-3/4"
5-1/4" 5-1/4"
162-205
162-206
3-3/4"
5-1/4"Lightweight
5-1/4"Heavyweight
3-1/4"Lightweight
3-1/4"Heavyweight
1" to 1/4"For Vertical
1" to 1/4"For Vertical
1" Vertical Tongue
1/4" Vertical Tongue
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
4©KAWNEER COMPANY, INC., 2006
PRESSURE PLATE
PERIMETERS
Open Back Filler 5-1/4" & 6"
System
Open Back Filler 6-3/4" & 7-1/2"
System
Description
162-020
ProfileExtrusion #
OPEN BACK FILLERS
162-021
2-1/2"Optional Cover
162-074
1-1/4"Optional Cover
162-073
SNAP-ON COVERSExtrusion # Profile
162-006
Description
3/4"Standard Cover
162-2393"
Optional Cover
Part #
5-1/4" & 6" System
Description
PRE-PUNCHED SHEAR BLOCKS
162-384Head / Sill162-385Head / Sill
6-3/4" & 7-1/2" System
5-1/4" & 6" System Perimeter
6-3/4" & 7-1/2" System Perimeter
5-1/4" & 6" System Perimeter
6-3/4" & 7-1/2" System Perimeter
SHEAR BLOCK FASTENERS
A
A
B
B
C
C
162-041 Flush DoorAdapter Cover
162-358
162-336
Extrusion # Profile
162-335
Description
Standard dry glazed pressure plate.
Pre-punched for pressure
plate fasteners.
1" System162-505
1/4" System162-506
Flush Double Acting Door Adapter pressure
plate. For use with 162-041 cover. See
Entrance Details in this Take-Off Guide.
Optional dry glazed pressure plate. For use
with 162-074 (2-1/2") deep cover. Pre-punched
for pressure plate fasteners.
163-024
Jamb Channel5-1/4" & 6" System
Perimeter163-023
1/4" "F" Perimeter162-176
1" "F" Perimeter
Description
162-017
ProfileExtrusion #
Jamb Channel6-3/4" & 7-1/2"
SystemPerimeter A
A
162-552
Flush Single ActingDoor Adapter pressure
plate. For use with 162-041 cover. See
Entrance Details in thisTake-Off Guide.
128-394 Typical128-405
Vertical(2 per shear block)
Horizontal(2 per shear block)
162-377Intermed. Horiz.
162-378Intermed. Horiz.
162-331
162-332Head / Sill
Head / Sill
162-904 (16 Pages) E.C.#95449-095 (09/09/13)
Part # Profile Description
3-3/4"Mullion Sleeve162-306
Splice Sleeves
162-3075-1/4"
Mullion Sleeve
162-357
162-356
162-313
162-530
Sleeve
Sleeve
Sleeve
Sleeve
Sleeve
Sleeve
Sleeve
Sleeve
Joint Plug (1/4" Framing) (Typical)
Open Back Filler (24'-0" S/L)
Shear Block to Horizontal Fastener
Cover (24'-0" S/L)
Thermal Separator (250' Roll)
Vertical Silicone Spacer - Typical (250' Roll)Interior / Exterior Weathering (250' Roll)
Setting Block (1/4" Framing)Pressure Plate Fastener
DESCRIPTION
Vertical (24'-0" S/L)Horizontal (24'-0" S/L)
162-325
5
Make Proper SelectionMake Proper Selection
128-405
027-854128-406
027-850027-475
Make Proper Selection
PART NUMBER
Make Proper Selection
Stock Lengths Required
Pr. Pl. Vert./Horiz. Footage
Stock Lengths Required
2 x SSG Vertical Footage4 x Pr. Pl. Vert./Horiz. Footage
2 Per Shear Block
2 Per D.L.O.1.8 x Thermal Separator
TAKE-OFF GUIDE
Stock Lengths RequiredStock Lengths Required
Vertical Silicone Spacer (See Detals) 027-648 2 x SSG Vertical Footage
Joint Plug (1/4" Framing) (Typical) 162-322 For Pr. Pl. Vert. (2 Per Horiz.)
162-310
Setting Block (1" Framing) 027-853 2 Per D.L.O.
Glazing Pressure Plate (24'-0" S/L) 162-335 Stock Lengths Required
Shear Block See Shear Block Chart 2 Per HorizontalShear Block to Vertical Fastener 128-394 2 Per Shear Block
Joint Plug (1" Framing) (Typical) 162-321 For Pr. Pl. Vert. (2 Per Horiz.)1 Per Horizontal SSG Vert.
Joint Plug (1" Framing) (Typical) 162-324 1 Per Horizontal SSG Vert.Perimeter "A" Joint Plug (1/4" Framing) 162-514 For Pr. Pl. Vert. (2 Per Horiz.)Perimeter "A" Joint Plug (1" Framing) 162-512 For Pressure Plate Verticals
GLAZING COVER
VERTICAL
SHEAR BLOCK
JOINT PLUG
OPEN BACK FILLER
EXTERIOR WEATHERING
GLAZING PRESSURE PLATE
©KAWNEER COMPANY, INC., 2006
Perimeter "A" Joint Plug (1" Framing) 162-513 For SSG Verticals (1 Per Horiz.)Perimeter "A" Joint Plug (1/4" Framing) 162-515 For SSG Verticals (1 Per Horiz.)Perimeter "C" Vertical End Caps 1" 162-388 2 Per VerticalPerimeter "C" Vertical End Caps 1/4" 162-389 2 Per Vertical
HORIZONTAL
THERMAL SEPARATOR
INTERIOR WEATHERING
Note: For other applications and accessories, reference shop drawings, installation instructions and Kawneer's website at www.kawneer.com.
162-904 (16 Pages) E.C.#95449-095 (09/09/13)
6
SHIM AS REQUIRED
EXTERIOR FRAME PERIMETER
Note: Requires Head / Sill Shear Blocks: 162-384 6" System 162-385 7-1/2" System Head / Sill Joint Plugs: 162-512 1" Framing Captured Verticals 162-514 1/4" Framing Captured Verticals 162-513 1" Framing SSG Verticals 162-515 1/4" Framing SSG Verticals
Use "F" & "T" Anchors
"F" PERIMETER
Note:Use a 162-017 or 162-176 without F or T anchors only
if mullion end reactions are less than 350 pounds.
Note: Requires Head / Sill Shear Blocks: 162-331 6" System 162-332 7-1/2" System
Use typical joint plugs.
PERIMETER GASKET
BY OTHERS.SEALANT AND BACK-UP ROD
027-857 PERIMETER GASKET
BY OTHERS.SEALANT AND BACK-UP ROD
PER JOB CONDITION
SEALANT
SHIM AS REQUIRED
SHIM AS REQUIRED
A
B
162-176 "F" PERIMETER FOR 1/4"162-017 "F" PERIMETER,
162-2
03
162-2
04
162-2
05
162-2
06
162-0
94
162-0
95
©KAWNEER COMPANY, INC., 2006
027-857
PERIMETER GASKET027-857
BY OTHERS.
BY OTHERS.
BY OTHERS.BY OTHERS.
162-904 (16 Pages) E.C.#95449-095 (09/09/13)
7
027-857 PERIMETER GASKET
BY OTHERS.SEALANT AND BACK-UP ROD
SHIM AS REQUIREDBY OTHERS.
PERIMETER PRESSURE PLATES
Note: Requires Head / Sill Shear Blocks: 162-331 6" System 162-332 7-1/2" System Typical Joint Plugs
Use "F" & "T" Anchors
Note: Uses vertical top & bottom end caps 162-388 (1") 162-389 (1/4")
027-857 PERIMETER GASKET
BY OTHERS.SEALANT AND BACK-UP ROD
SHIM AS REQUIREDBY OTHERS.
C
162-0
94
162-0
95
162-0
96
162-0
97
162-505PRESSURE PLATE
162-506PRESSURE PLATE
©KAWNEER COMPANY, INC., 2006162-904 (16 Pages) E.C.#95449-095 (09/09/13)
8
INTERMEDIATES
Note: Requires Intermediate Shear Blocks: 162-377 6" System 162-378 7-1/2" System Typical Joint Plugs
162-0
01
162-0
03
162-335PRESSURE PLATE
162-025
162-027
162-335PRESSURE PLATE
162-025
162-027
OPTIONAL
162-030VERTICAL TONGUE
027-648
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
9
"T" Anchor
"F" Anchor
"F" AND "T" ANCHOR CHARTS
MULLIONPART NUMBER
162-327
F - Anchor ChartTo be used with
162-329
5-1/4" & 6"
6-3/4" & 7-1/2"
System
PART NUMBER
162-328
T - Anchor ChartTo be used with
162-330
5-1/4" & 6"
6-3/4" & 7-1/2"
System
Note:T- anchors must be used if mullion end reactions exceed 350pounds. If mullion end-reactions are less than 350 pounds, thenperimeter anchoring may be used. (See page 4).
End Reactions = Module (ft.) x Length (ft.) x Windload (PSF) (Pounds) 2
162-025, 162-026
162-027, 162-028
FASTENERPREPS
"T" ANCHOR("F" ANCHOR SIMILAR)
162-025, 162-026
162-027, 162-028
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
10
90° INSIDE CORNERS
162-108
162-405
028-523
162-109
162-108
162-405
162-257
162-405
028-523
162-109
162-257
162-405
162-256 162-256
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
11
90° OUTSIDE CORNERS 162-405
162-101
162-405
162-102
162-101
162-405
162-254
162-405
162-102
162-254
162-255 162-255
028-336
028-336
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
12
ENTRANCE DETAILS
Entrance Adapters - 1" Framing
· Surface mounted closer only.· Offset pivots or butt hinges.
TRANSOM BARSingle Acting
2-1
/2"
069-177(Assembly includes bothextrusions and weathering.)
162-041
162-336
162-0
01
162-0
03
DOOR JAMBSingle Acting
2-1/2"
069-177
162-336
162-041
162-025
162-027
162-030VERTICAL TONGUE
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
13
· Use with butts, O.S. pivots, or center hung hinges.· Use with concealed or surface mounted closer.
TRANSOM BAR
DOOR JAMB
NOTES: · Mullion & cover extrusion numbers per
job requirements. · Details may vary according to hanging
and closer combinations used. Typicaldetails shown.
· Use assembly 450-520 in lieu of 450-087if doors are hung offset.
ENTRANCE SUB-FRAME - 1" AND 1/4" FRAMING
1" System Shown, 1/4" System Similar
2-1/2" 3/4"
450-087
162-043
162-025
162-027
027-648
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)
15
STANDARD INTERMEDIATE DEAD LOAD AND WIND LOAD MID-ANCHOR DETAILS
For Alternate Detail Condition Consult Factory.
MULLION
VARIES
DEAD LOAD
216301 SLIP WASHER
027-477SEPARATOR
027-477SEPARATOR
STEEL ANCHORS
THRU BOLTSAS REQUIRED
WIND LOAD
THRU BOLTSAS REQUIRED
STEEL ANCHORS
©KAWNEER COMPANY, INC., 2012162-904 (16 Pages) E.C.#95449-91 (10/04/12)