PREDIMENSIONAMIENTO DE COLUMNAS At = K*Ac PISO UZ LIBRE (m At: Area de columna ANTEPENULTI 4.00 K: coeficiente 6.00 Ac: Area tributaria que carga la columna por nivel 8.00 4.00 SEGUNDO PIS 6.00 8.00 CONSIDERACION: DE ACUERDO AL REGLAMENTO NACIONAL DE EDIFICACIONES LAS COLUMNAS A CONSIDERAR ES: 25X25 cm

Upload: angel-eduardo-bazan-sanchez

Post on 10-Feb-2016

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Estructuras y Cargas T2 Arenas Alvarado Piero

PREDIMENSIONAMIENTO DE COLUMNAS

At = K*Ac PISO LUZ LIBRE (m)AREA TRIBUTARIA POR PISO (m2)

At: Area de columna ANTEPENULT 4.00K: coeficiente 6.00Ac: Area tributaria que carga la columna por nivel 8.00

4.00SEGUNDO PI 6.00

8.00

CONSIDERACION:DE ACUERDO AL REGLAMENTO NACIONAL DE EDIFICACIONES LAS COLUMNAS (RNE) A CONSIDERAR ES: 25X25 cm

Page 2: Estructuras y Cargas T2 Arenas Alvarado Piero

AREA TRIBUTARIA POR PISO (m2) TIPO DE COLUMNAC-1 C-2 C-3 C-4

16.00 0.0013 0.0025 0.0022 0.004036.00 0.0011 0.0020 0.0016 0.002864.00 0.0011 0.0017 0.0014 0.002316.00 0.0011 0.0014 0.0014 0.002136.00 0.0012 0.0014 0.0014 0.001564.00 0.0014 0.0014 0.0014 0.0015

Page 3: Estructuras y Cargas T2 Arenas Alvarado Piero

PREDIMENSIONAMIENTO DE VIGAS SECUNDARIAS

RANGO A TENER EN CUENTA PARA EL PERALTE b=(0.3 a 0.5) Ln/10 ó Ln/12

EJE 1-1 VIGA SECUNDARIATRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO A-B h(v-s) 0.28 0.23 0.25 25 25X25 cmb(v-s) 10

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO B-C h(v-s) 0.20 0.17 0.18 20 25X20

b(v-s) 8TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO C-D h(v-s) 0.33 0.27 0.30 30 25X30b(v-s) 12

EJE 2-2 VIGA SECUNDARIATRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO A-B h(v-s) 0.28 0.23 0.25 25 25X25 cmb(v-s) 10

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO B-C h(v-s) 0.20 0.17 0.18 20 25X20

b(v-s) 8TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO C-D h(v-s) 0.33 0.27 0.30 30 25X30b(v-s) 12

EJE 3-3 VIGA SECUNDARIATRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO A-B h(v-s) 0.28 0.23 0.25 25 25X25 cmb(v-s) 10

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO B-C h(v-s) 0.20 0.17 0.18 20 25X20

b(v-s) 8TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO C-D h(v-s) 0.33 0.27 0.30 30 25X30b(v-s) 12

EJE 4-4 VIGA SECUNDARIATRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO A-B h(v-s) 0.28 0.23 0.25 25 25X25b(v-s) 10

Page 4: Estructuras y Cargas T2 Arenas Alvarado Piero

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO B-C h(v-s) 0.20 0.17 0.18 20 25X20

b(v-s) 8TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO C-D h(v-s) 0.33 0.27 0.30 30 25X30b(v-s) 12

PREDIMENSIONAMIENTO DE VIGAS PRINCIPALES

EJE A-A VIGA PRINCIPALTRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 1-2 h(v-p) 0.38 0.31 0.34 35 25X35b(v-p) 14

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO 2-3 h(v-p) 0.25 0.21 0.23 25 25x25

b(v-p) 10TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 3-4 h(v-p) 0.18 0.15 0.16 20 25x20b(v-p) 8

EJE B-B VIGA PRINCIPALTRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 1-2 h(v-p) 0.38 0.31 0.34 35 25X35b(v-p) 14

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO 2-3 h(v-p) 0.25 0.21 0.23 25 25x25

b(v-p) 10

EJE C-C VIGA PRINCIPALTRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 1-2 h(v-p) 0.38 0.31 0.34 35 25X35b(v-p) 14

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO 2-3 h(v-p) 0.25 0.21 0.23 25 25x25

b(v-p) 10

EJE D-D VIGA PRINCIPALTRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 1-2 h(v-p) 0.38 0.31 0.34 35 25X35b(v-p) 14

TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERARTRAMO 2-3 h(v-p) 0.25 0.21 0.23 25 25x25

b(v-p) 10TRAMO PERALTE(h) Ln/10 Ln/12 PROMEDIO VIGA A CONSIDERAR

TRAMO 3-4 h(v-p) 0.18 0.15 0.16 20 25x20b(v-p) 8

Page 5: Estructuras y Cargas T2 Arenas Alvarado Piero

PREDIMENSIONAMIENTO DE LOSA

h > ó = Ln/(17,20,25,30)Ln= 3.75

e = Ln/20e = 0.188

tomaremos un espesor de losa de e = 0.20 cm

Page 6: Estructuras y Cargas T2 Arenas Alvarado Piero

PREDIMENSIONAMIENTO DE LOSA

Page 7: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DE ESCALERAS

CRITERIOS A CONSIDERAR

P = 0.25 Piso terminado = 100 Kg/m2CP = 0.17 S/C = 200 Kg/m2

A. Predimensionamiento ln(luz apoyo)= 3

t= ln/25 ln/30 3.5*lnt= 12 10 10.5t= 10.8333333

ASUMIMOS QUE "t" 0.11

A.1 Cálculo de pendiente

arcotg(P/CP)α = 34.21°

Pendiente X 1/COS(α ) X = 1.712

B. Metrado de cargas

B.1 Carga muerta

Peso propio Losa 2400 1.21 0.11 319.44Peso escalera 2400 0.02125 4 204P. terminado 100 1 100

Ʃ CM = 623.44 kg/m

B.2 Carga viva

Sobre carga 200 1 200

Ʃ CV = 200 kg/m

c CU = 1.4CM+1.7CVCU = 1212.816

C. Reacciones (Momento max. y min.)

Cálculo de α =

Page 8: Estructuras y Cargas T2 Arenas Alvarado Piero

M(-) = M(+) =

M(-) = 682.209 M(+) = 1091.5344

(𝐶_𝑢∗𝐿^2)/16 (𝐶_𝑢∗𝐿^2)/10

Page 9: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DE COLUMNAS

Peso losa aligerada h= 20 cm 300 Kg/m2Peso específico CA 2400 Kg/m2Peso específico albañilería 1800 Kg/m3 Peso acabados 100 Kg/m2Sobrecarga 200 Kg/m2Tabiqueria 200 kg/m2Considerar 1.00 metro para el área de influencia de los elementos secundarios

Peso propio en la losa aligerada del 1º y 2º Nivel

Losa aligerada h=0.20 300 Kg/m2Acabados 100 Kg/m2Peso total 400 Kg/m2

METRADO DEL EJE 1-1 (COLUMNA 1-A)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 1.375 1.875P.VP Losa-2 2400 1.875 0.25 0.35P.VS Losa-2 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.875 2.35P.P.E.S. Losa2 400 1.875 1

LO

SA

1 P.VP Losa-1 2400 1.875 0.25 0.35P.VS Losa-1 2400 1.375 0.25 0.25P. Losa 400 1.375 1.875P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.375 1.875 515.625S/C 2° nivel-S 200 1 1.875 375S/C 1° nivel 200 1.375 1.875 515.625S/C 1° nivel-S 200 1 1.875 375

Ʃ CV = 1781.25

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 11403.188 Kg

Page 10: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DEL EJE 1-1 (COLUMNA 1-B)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 2.375 1.875P.VP Losa-2 2400 1.875 0.25 0.35P.VS Losa-2 (201) 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.875 2.35P.P.E.S. Losa2 400 1.875 2

LO

SA

1 P.VP Losa-1 2400 1.875 0.25 0.35P.VS Losa-1 (201) 2400 1.375 0.25 0.25P. Losa 400 2.375 1.875P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 2.375 1.875 890.625S/C 2° nivel-S 200 2 1.875 750S/C 1° nivel 200 2.375 1.875 890.625S/C 1° nivel-S 200 2 1.875 750

Ʃ CV = 3281.25

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 17439.188 Kg

METRADO DEL EJE 1-1 (COLUMNA 1-C)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 2.625 1.875P.VP Losa-2 2400 1.875 0.25 0.35P.VS Losa-2 (202) 2400 1 0.25 0.2P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.875 2.35P.P.E.S. Losa2 400 1.875 2

LO

SA

1 P.VP Losa-1 2400 1.875 0.25 0.35P.VS Losa-1 (201) 2400 1 0.25 0.2P. Losa 400 2.625 1.875P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

Page 11: Estructuras y Cargas T2 Arenas Alvarado Piero

S/C 2° nivel 200 2.625 1.875 984.375S/C 2° nivel-S 200 2 1.875 750S/C 1° nivel 200 2.625 1.875 984.375S/C 1° nivel-S 200 2 1.875 750

Ʃ CV = 3468.75

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 18524.438

METRADO DEL EJE 1-1 (COLUMNA 1-D)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 1.625 1.875P.VP Losa-2 2400 1.875 0.25 0.35P.VS Losa-2 2400 1.625 0.25 0.3P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.875 2.35P.P.E.S. Losa2 400 1.875 1

LO

SA

1 P.VP Losa-1 2400 1.875 0.25 0.35P.VS Losa-1 2400 1.625 0.25 0.3P. Losa 400 1.625 1.875P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.625 1.875 609.375S/C 2° nivel-S 200 1 1.875 375S/C 1° nivel 200 1.625 1.875 609.375S/C 1° nivel-S 200 1 1.875 375

Ʃ CV = 1968.75

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 12488.438

METRADO DEL EJE 2-2 (COLUMNA 2-A)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 3.125 1.375P.VP Losa-2 (101) 2400 1.875 0.25 0.35

Page 12: Estructuras y Cargas T2 Arenas Alvarado Piero

L

OSA

2 P.VS Losa-2 (201) 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 3.125 2.35P.P.E.S. Losa2 400 3.125 1

LO

SA

1 P.VP Losa-1 (101) 2400 1.875 0.25 0.35P.VS Losa-1 (201) 2400 1.375 0.25 0.25P. Losa 400 1.375 3.125P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.375 3.125 859.375S/C 2° nivel-S 200 1 3.125 625S/C 1° nivel 200 1.375 3.125 859.375S/C 1° nivel-S 200 1 3.125 625

Ʃ CV = 2968.75

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 17682.313 Kg

METRADO DEL EJE 2-2 (COLUMNA 2-B)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 3.125 2.375P.VP Losa-2 (101) 2400 1.875 0.25 0.35P.VS Losa-2 (201) 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 3.125 2.35P.P.E.S. Losa2 400 3.125 2

LO

SA

1 P.VP Losa-1 (101) 2400 1.875 0.25 0.35P.VS Losa-1 (201) 2400 1.375 0.25 0.25P. Losa 400 1.375 3.125P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 2.375 3.125 1484.375S/C 2° nivel-S 200 2 3.125 1250S/C 1° nivel 200 2.375 3.125 1484.375S/C 1° nivel-S 200 2 3.125 1250

Page 13: Estructuras y Cargas T2 Arenas Alvarado Piero

Ʃ CV = 5468.75

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 25768.313 Kg

METRADO DEL EJE 2-2 (COLUMNA 2-C)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 3.125 2.625P.VP Losa-2 (101) 2400 1.875 0.25 0.35P.VS Losa-2 (202) 2400 1 0.25 0.2P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 3.125 2.35P.P.E.S. Losa2 400 3.125 2

LO

SA

1 P.VP Losa-1 (101) 2400 1.875 0.25 0.35P.VS Losa-1 (202) 2400 1 0.25 0.2P. Losa 600 1.375 3.125P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 2.625 3.125 1640.625S/C 2° nivel-S 200 2 3.125 1250S/C 1° nivel 200 2.625 3.125 1640.625S/C 1° nivel-S 200 2 3.125 1250

Ʃ CV = 5781.25

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 28181.688 Kg

METRADO DEL EJE 2-2 (COLUMNA 2-D)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 3.125 1.625P.VP Losa-2 (101) 2400 1.875 0.25 0.35P.VS Losa-2 (203) 2400 1.625 0.25 0.3P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 3.125 2.35P.P.E.S. Losa2 400 3.125 1

LO

SA

1 P.VP Losa-1 (101) 2400 1.875 0.25 0.35P.VS Losa-1 (203) 2400 1.625 0.25 0.3

Page 14: Estructuras y Cargas T2 Arenas Alvarado Piero

LO

SA

1

P. Losa 600 1.375 3.125P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.625 3.125 1015.625S/C 2° nivel-S 200 1 3.125 625S/C 1° nivel 200 1.625 3.125 1015.625S/C 1° nivel-S 200 1 3.125 625

Ʃ CV = 3281.25

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 20095.688 Kg

METRADO DEL EJE 3-3 (COLUMNA 3-A)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 1.375 1.25P.VP Losa-2 (102) 2400 1.25 0.25 0.25P.VS Losa-2 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 2.125 2.35P.P.E.S. Losa2 400 1.25 1

LO

SA

1 P.VP Losa-1 (102) 2400 1.25 0.25 0.25P.VS Losa-1 2400 1.375 0.25 0.25P. Losa 400 1.375 1.875P.P. Columna 2600 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.375 1.25 343.75S/C 2° nivel-S 200 1 1.25 250S/C 1° nivel 200 1.375 1.25 343.75S/C 1° nivel-S 200 1 1.25 250

Ʃ CV = 1187.5

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 9133.2 Kg

Page 15: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DEL EJE 3-3 (COLUMNA 3-B)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 2.375 1.25P.VP Losa-2 2400 1.25 0.25 0.25P.VS Losa-2 (201) 2400 1.375 0.25 0.25P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.25 2.35P.P.E.S. Losa2 400 1.25 2

LO

SA

1 P.VP Losa-1 2400 1.25 0.25 0.25P.VS Losa-1 (201) 2400 1.375 0.25 0.25P. Losa 400 2.375 1.25P.P. Columna 2600 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 2.375 1.25 593.75S/C 2° nivel-S 200 2 1.25 500S/C 1° nivel 200 2.375 1.25 593.75S/C 1° nivel-S 200 2 1.25 500

Ʃ CV = 2187.5

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 12130.125 Kg

METRADO DEL EJE 3-3 (COLUMNA 3-C)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 2.625 1.25P.VP Losa-2 2400 1.25 0.25 0.25P.VS Losa-2 (202) 2400 1 0.25 0.2P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 1.25 2.35P.P.E.S. Losa2 400 1.25 2

LO

SA

1 P.VP Losa-1 2400 1.25 0.25 0.25P.VS Losa-1 (202) 2400 1 0.25 0.2P. Losa 600 2.625 1.25P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

Page 16: Estructuras y Cargas T2 Arenas Alvarado Piero

S/C 2° nivel 200 2.625 1.25 656.25S/C 2° nivel-S 200 2 1.25 500S/C 1° nivel 200 2.625 1.25 656.25S/C 1° nivel-S 200 2 1.25 500

Ʃ CV = 2312.5

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 13807.375 Kg

METRADO DEL EJE 3-3 (COLUMNA 3-D)

Carga muerta

L

OSA

2

P.P.T. Losa-2 400 1.625 1.25P.VP Losa-2 (102) 2400 1.25 0.25 0.25P.VS Losa-2 2400 1.625 0.25 0.3P.P. Columna 2400 2.6 0.25 0.25P.P. Muro 1800 0.15 2.125 2.35P.P.E.S. Losa2 400 1.25 1

LO

SA

1 P.VP Losa-1 (102) 2400 1.25 0.25 0.25P.VS Losa-1 2400 1.625 0.25 0.3P. Losa 600 1.25 1.625P.P. Columna 2400 2.6 0.25 0.25

Ʃ CM =

Carga viva

S/C 2° nivel 200 1.625 1.25 406.25S/C 2° nivel-S 200 1 1.25 250S/C 1° nivel 200 1.625 1.25 406.25S/C 1° nivel-S 200 1 1.25 250

Ʃ CV = 1312.5

CARGA ULTIMA (CU) CU=1.4CM+1.7CV 10392.638 Kg

Page 17: Estructuras y Cargas T2 Arenas Alvarado Piero

1031.25393.75206.25

3901189.6875

750393.75206.25

1031.25390

5982.1875

Page 18: Estructuras y Cargas T2 Arenas Alvarado Piero

1781.25393.75206.25 P.VS Losa-2 (202)= 120

3901189.6875

1500393.75206.25 P.VS Losa-2 (202)= 120

1781.25390

8472.1875

1968.75393.75

120 P.VS Losa-2 (203)= 292.5390

1189.68751500

393.75120 P.VS Losa-2 (202)= 292.5

1968.75390

9019.6875

Page 19: Estructuras y Cargas T2 Arenas Alvarado Piero

1218.75393.75

292.5390

1189.6875750

393.75292.5

1218.75390

6529.6875

1718.75393.75 P.VP Losa-2 (102)= 187.5

Page 20: Estructuras y Cargas T2 Arenas Alvarado Piero

206.25390

1982.81251250

393.75 P.VP Losa-1 (102)= 187.5206.25

1718.75390

9025.3125

2968.75393.75 P.VP Losa-2 (102)= 187.5206.25 P.VS Losa-2 (202)= 120

3901982.8125

2500393.75 P.VP Losa-1 (102)= 187.5206.25 P.VS Losa-1 (202)= 120

1718.75390

11765.313

Page 21: Estructuras y Cargas T2 Arenas Alvarado Piero

3281.25393.75 P.VP Losa-2 (102)= 187.5

120 P.VS Losa-2 (202)= 292.5390

1982.81252500

393.75 P.VP Losa-1 (102)= 187.5120 P.VS Losa-1 (202)= 292.5

2578.125390

13109.688

2031.25393.75 P.VP Losa-2 (102)= 187.5

292.5390

1982.81251250

393.75 P.VP Losa-1 (102)= 187.5292.5

Page 22: Estructuras y Cargas T2 Arenas Alvarado Piero

2578.125390

10369.688

687.546.875 P.VP Losa-2 (103)= 105

51.5625390

1348.3125500

187.5 P.VP Losa-1 (103)= 105206.25

1031.25422.5

5081.75

Page 23: Estructuras y Cargas T2 Arenas Alvarado Piero

1187.5187.5

206.25 P.VS Losa-2 (202)= 120390

793.1251000

187.5206.25 P.VS Losa-2 (202)= 1201187.5

422.5

6008.125

1312.5187.5

120 P.VS Losa-2 (203)= 292.5390

793.1251000

187.5120 P.VS Losa-2 (202)= 292.5

1968.75390

7054.375

Page 24: Estructuras y Cargas T2 Arenas Alvarado Piero

812.5187.5 P.VP Losa-2 (103)= 105292.5

3901348.3125

500187.5 P.VP Losa-1 (103)= 105292.5

1218.75390

5829.5625

Page 25: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DE VIGAS

METRADO DEL EJE 1-1 (Tramo A-1)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 1.88 750.00

Ʃ CM = 1534.50

CU = 1.4*WD+1.7*WLCU = 2785.8

METRADO DEL EJE 1-1 (Tramo 1-2)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 1.00 270.00Peso de la losa 400 1.88 750.00

Ʃ CM = 1170.00

CU = 1.4*WD+1.7*WLCU = 2275.5

METRADO DEL EJE 1-1 (Tramo 2-B)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 1.88 750.00

Ʃ CM = 1534.50

CU = 1.4*WD+1.7*WLCU = 2785.8

METRADO DEL EJE 1-1 (Tramo B-C)

Carga muertaPeso propio viga 2400 0.25 0.20 120.00Peso del muro 1800 0.15 1.00 270.00Peso de la losa 400 1.88 750.00

Ʃ CM = 1140.00

Page 26: Estructuras y Cargas T2 Arenas Alvarado Piero

CU = 1.4*WD+1.7*WLCU = 2233.5

METRADO DEL EJE 1-1 (Tramo C-3)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 2.20 594.00Peso de la losa 400 1.88 750.00

Ʃ CM = 1524.00

CU = 1.4*WD+1.7*WLCU = 2771.1

METRADO DEL EJE 1-1 (Tramo 3-4)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 1.00 270.00Peso de la losa 400 1.88 750.00

Ʃ CM = 1200.00

CU = 1.4*WD+1.7*WLCU = 2317.5

METRADO DEL EJE 1-1 (Tramo 4-D)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 2.20 594.00Peso de la losa 400 1.88 750.00

Ʃ CM = 1524.00

CU = 1.4*WD+1.7*WLCU = 2771.1

METRADO DEL EJE 2-2 (Tramo A-B)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 3.125 1250.00

Page 27: Estructuras y Cargas T2 Arenas Alvarado Piero

Ʃ CM = 2034.50

CU = 1.4*WD+1.7*WLCU = 3910.8

METRADO DEL EJE 2-2 (Tramo B-C)

Carga muertaPeso propio viga 2400 0.25 0.20 120.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 400 3.125 1250.00

Ʃ CM = 1370.00

CU = 1.4*WD+1.7*WLCU = 2980.5

METRADO DEL EJE 2-2 (Tramo C-1)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 2.20 594.00Peso de la losa 600 3.125 1875.00

Ʃ CM = 2649.00

CU = 1.4*WD+1.7*WLCU = 4771.1

METRADO DEL EJE 2-2 (Tramo 1-D)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 600 3.125 1875.00

Ʃ CM = 2055.00

CU = 1.4*WD+1.7*WLCU = 3939.5

METRADO DEL EJE 3-3 (Tramo A-1)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50

Page 28: Estructuras y Cargas T2 Arenas Alvarado Piero

Peso de la losa 400 1.250 500.00Ʃ CM = 1284.50

CU = 1.4*WD+1.7*WLCU = 2223.3

METRADO DEL EJE 3-3 (Tramo 1-2)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 1.00 270.00Peso de la losa 400 1.250 500.00

Ʃ CM = 920.00

CU = 1.4*WD+1.7*WLCU = 1713

METRADO DEL EJE 3-3 (Tramo 2-B)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 1.250 500.00

Ʃ CM = 1284.50

CU = 1.4*WD+1.7*WLCU = 2223.3

METRADO DEL EJE 3-3 (Tramo B-3)

Carga muertaPeso propio viga 2400 0.25 0.20 120.00Peso del muro 1800 0.15 2.40 648.00Peso de la losa 400 1.250 500.00

Ʃ CM = 1268.00

CU = 1.4*WD+1.7*WLCU = 2200.2

METRADO DEL EJE 3-3 (Tramo 3-4)

Carga muertaPeso propio viga 2400 0.25 0.20 120.00

Page 29: Estructuras y Cargas T2 Arenas Alvarado Piero

Peso del muro 1800 0.15 1.00 270.00Peso de la losa 400 1.250 500.00

Ʃ CM = 890.00

CU = 1.4*WD+1.7*WLCU = 1671

METRADO DEL EJE 3-3 (Tramo 4-C)

Carga muertaPeso propio viga 2400 0.25 0.20 120.00Peso del muro 1800 0.15 2.40 648.00Peso de la losa 400 1.250 500.00

Ʃ CM = 1268.00

CU = 1.4*WD+1.7*WLCU = 2200.2

METRADO DEL EJE 3-3 (Tramo C-5)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 2.30 621.00Peso de la losa 600 1.250 750.00

Ʃ CM = 1551.00

CU = 1.4*WD+1.7*WLCU = 2596.4

METRADO DEL EJE 3-3 (Tramo 5-6)

Carga muertaPeso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 1.80 486.00Peso de la losa 600 1.250 750.00

Ʃ CM = 1416.00

CU = 1.4*WD+1.7*WLCU = 2407.4

METRADO DEL EJE 3-3 (Tramo 6-D)

Carga muerta

Page 30: Estructuras y Cargas T2 Arenas Alvarado Piero

Peso propio viga 2400 0.25 0.30 180.00Peso del muro 1800 0.15 2.30 621.00Peso de la losa 600 1.250 750.00

Ʃ CM = 1551.00

CU = 1.4*WD+1.7*WLCU = 2596.4

METRADO DEL EJE A-A (Tramo 1-2)

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 2.25 607.50Peso de la losa 400 1.375 550.00

Ʃ CM = 1367.50

CU = 1.4*WD+1.7*WLCU = 2382

METRADO DEL EJE A-A (Tramo 2-1)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 1.375 550.00

Ʃ CM = 1334.50

CU = 1.4*WD+1.7*WLCU = 2335.8

METRADO DEL EJE B-B (Tramo 1-a)

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 2.25 607.50Peso de la losa 400 2.375 950.00

Ʃ CM = 1767.50

CU = 1.4*WD+1.7*WLCU = 3282

METRADO DEL EJE B-B (Tramo a-2)

Page 31: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 400 2.375 950.00

Ʃ CM = 1160.00

CU = 1.4*WD+1.7*WLCU = 2431.5

METRADO DEL EJE B-B (Tramo 2-b)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 400 2.375 950.00

Ʃ CM = 1734.50

CU = 1.4*WD+1.7*WLCU = 3235.8

METRADO DEL EJE B-B (Tramo b-3)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 400 2.375 950.00

Ʃ CM = 1100.00

CU = 1.4*WD+1.7*WLCU = 2347.5

METRADO DEL EJE C-C (Tramo 1-a)

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 2.25 607.50Peso de la losa 400 2.625 1050.00

Ʃ CM = 1867.50

CU = 1.4*WD+1.7*WLCU = 3507

METRADO DEL EJE C-C (Tramo a-2)

Page 32: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 400 2.625 1050.00

Ʃ CM = 1260.00

CU = 1.4*WD+1.7*WLCU = 2656.5

METRADO DEL EJE C-C (Tramo 2-b)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 600 2.625 1575.00

Ʃ CM = 2359.50

CU = 1.4*WD+1.7*WLCU = 4195.8

METRADO DEL EJE C-C (Tramo b-3)

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 0.00 0.00Peso de la losa 600 2.625 1575.00

Ʃ CM = 1725.00

CU = 1.4*WD+1.7*WLCU = 3307.5

METRADO DEL EJE D-D (Tramo 1-2)

Carga muertaPeso propio viga 2400 0.25 0.35 210.00Peso del muro 1800 0.15 2.25 607.50Peso de la losa 400 1.625 650.00

Ʃ CM = 1467.50

CU = 1.4*WD+1.7*WLCU = 2607

METRADO DEL EJE D-D (Tramo 2-3)

Page 33: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga muertaPeso propio viga 2400 0.25 0.25 150.00Peso del muro 1800 0.15 2.35 634.50Peso de la losa 600 1.625 975.00

Ʃ CM = 1759.50

CU = 1.4*WD+1.7*WLCU = 3015.8

Page 34: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Page 35: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 1.875 375

Ʃ CV = 375

Carga vivaS/C 200 3.125 625

Ʃ CV = 625

Page 36: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 3.125 625

Ʃ CV = 625

Carga vivaS/C 200 3.125 625

Ʃ CV = 625

Carga vivaS/C 200 3.125 625

Ʃ CV = 625

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Page 37: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Page 38: Estructuras y Cargas T2 Arenas Alvarado Piero

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga vivaS/C 200 1.25 250

Ʃ CV = 250

Carga viva

Page 39: Estructuras y Cargas T2 Arenas Alvarado Piero

S/C 200 1.25 250Ʃ CV = 250

Carga vivaS/C 200 1.375 275

Ʃ CV = 275

Carga vivaS/C 200 1.375 275

Ʃ CV = 275

Carga vivaS/C 200 2.375 475

Ʃ CV = 475

Page 40: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 2.375 475

Ʃ CV = 475

Carga vivaS/C 200 2.375 475

Ʃ CV = 475

Carga vivaS/C 200 2.375 475

Ʃ CV = 475

Carga vivaS/C 200 2.625 525

Ʃ CV = 525

Page 41: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 2.625 525

Ʃ CV = 525

Carga vivaS/C 200 2.625 525

Ʃ CV = 525

Carga vivaS/C 200 2.625 525

Ʃ CV = 525

Carga vivaS/C 200 1.625 325

Ʃ CV = 325

Page 42: Estructuras y Cargas T2 Arenas Alvarado Piero

Carga vivaS/C 200 1.625 325

Ʃ CV = 325

Page 43: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DE COMIENTOS Y VIGUETAS

Zapatas Cantidad de Viguetasσ (kg/cm2) PPz en P%

1 8% P2 5% P3 4% P4 3% P

P= Carga de servicio (CV+CM)PPz= Peso Propio de Zapata

σ= Ezfuerzo admisible terreno

METRADO DEL EJE 1-1 (COLUMNA 1-A) (σ=1kg/cm2)

P= CM+CV Az=P= 7763.4375

PPz= 621.075 Az= 8384.5125 cm2

L= 91.56698367862 cmL= 0.91m 1.00m

METRADO DEL EJE 1-1 (COLUMNA 2-B) (σ=1kg/cm2)

P= CM+CV Az=P= 11753.4375

PPz= 940.275 Az= 12693.7125 cm2

L= 112.666376972 cmL= 1.12m 1.00m

METRADO DEL EJE 1-1 (COLUMNA 1-C) (σ=1kg/cm2)

P= CM+CV Az=P= 12488.4375

PPz= 999.075 Az= 13487.5125 cm2

L= 116.1357503097 cmL= 1.16m 1.00m

((𝐿𝑢𝑧 𝑑𝑒𝑙 𝑝𝑎ñ𝑜)/0.4)-1

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

Page 44: Estructuras y Cargas T2 Arenas Alvarado Piero

METRADO DEL EJE 1-1 (COLUMNA 1-D) (σ=1kg/cm2)

P= CM+CV Az=P= 8498.4375

PPz= 679.875 Az= 9178.3125 cm2

L= 95.8035098522 cmL= 0.95m 1.00m

METRADO DEL EJE 2-2 (COLUMNA 2-A) (σ=1kg/cm2)

P= CM+CV Az=P= 11994.0625

PPz= 959.525 Az= 12953.5875 cm2

L= 113.813828246 cmL= 1.13m 1.00m

METRADO DEL EJE 2-2 (COLUMNA 2-B) (σ=1kg/cm2)

P= CM+CV Az=P= 17234.0625

PPz= 1378.725 Az= 18612.7875 cm2

L= 136.4286901645 cmL= 1.36m 1.00m

METRADO DEL EJE 2-2 (COLUMNA 2-C) (σ=1kg/cm2)

P= CM+CV Az=P= 18890.9375

PPz= 1511.275 Az= 20402.2125 cm2

L= 142.8363136601 cmL= 1.42m 1.00m

METRADO DEL EJE 2-2 (COLUMNA 2-D) (σ=1kg/cm2)

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

Page 45: Estructuras y Cargas T2 Arenas Alvarado Piero

P= CM+CV Az=P= 13650.9375

PPz= 1092.075 Az= 14743.0125 cm2

L= 121.4208075249 cmL= 1.21m 1.00m

METRADO DEL EJE 3-3 (COLUMNA 3-A) (σ=1kg/cm2)

P= CM+CV Az=P= 6269.25

PPz= 501.54 Az= 6770.79 cm2

L= 82.28481026289 cmL= 0.82m 1.00m

METRADO DEL EJE 3-3 (COLUMNA 3-B) (σ=1kg/cm2)

P= CM+CV Az=P= 8195.625

PPz= 655.65 Az= 8851.275 cm2

L= 94.08121491562 cmL= 0.94m 1.00m

METRADO DEL EJE 3-3 (COLUMNA 3-C) (σ=1kg/cm2)

P= CM+CV Az=P= 9366.875

PPz= 749.35 Az= 10116.225 cm2

L= 100.5794462104 cmL= 1.01m 1.00m

METRADO DEL EJE 3-3 (COLUMNA 3-D) (σ=1kg/cm2)

P= CM+CV Az=P= 7142.0625

PPz= 571.365 Az= 7713.4275 cm2

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

(𝑃+ 〖𝑃𝑃〗_𝑍)/𝜎_𝑡

Page 46: Estructuras y Cargas T2 Arenas Alvarado Piero

L= 87.82612082974 cmL= 0.88m 1.00m