etap 60 new features
TRANSCRIPT
-
8/7/2019 Etap 60 New Features
1/24
New Features
-
8/7/2019 Etap 60 New Features
2/242
ETAP Enterprise Solution
ETAP is the most comprehensive analysis platform for the design,simulation, operation, control, optimization, and automation ofgeneration, transmission, distribution, and industrial power systems.
ETAP offers a suite of fully integrated software solutions includingarc flash, load flow, short circuit, relay coordination, cable ampacity,transient stability, optimal power flow, and more. Its modularfunctionality can be tailored to fit the needs of any company, from smalto large power systems.
Quality Assurance CommitmentETAP is Verified and Validated (V&V) against field results, real systemmeasurements, established programs, and hand calculations to ensureits technical accuracy. Each release of ETAP undergoes a complete V&Vprocess using thousands of test cases for each and every calculationmodule.
One-Line Diagram ....................4
Arc Flash Analysis ....................8
Short-Circuit Analysis ............12
Star - Device Coordination ..... 14
Load Flow Analysis ................. 18
Transient Stability Analysis .... 19
Cable Systems ........................20
Data Exchange ........................22
ETAP Support ......................... 23
System Requirements ............23
ETAP Quality Assurance program is specificallydedicated to meeting the requirements of:
ISO 9001:2000 A3147 UL10 CFR 50 Appendix B
10 CFR 21ANSI/ASME N45.2
ASME NQA-1ANSI/IEEE 730.1
CAN/CSA-Q396.1.2ANSI N45.22
-
8/7/2019 Etap 60 New Features
3/243
Whats New in ETAP 6.0
ETAP 6.0 is a major release that incorporates a broad and robust set of new features and enhancementsincluding new analysis modules, time-saving capabilities as well as faster processing time, delivering
an unmatched level of mathematical precision and professionalism. Many of the new and enhancedfunctionalities are based on user input and suggestions. These enhancements come to you as a part ofyour ETAP upgrade.
Results You
Can Trust
Automated&
Intelligent
New FeaturesEnhanced Features
Delivering Unmatched Speed, Precision, & Reliability
Elements & Libraries
Recloserx
Differential Relayx
In-Line Overload Relayx
Maintenance Mode Settingx
Analysis Modules
Cable Ampacity - BS 7671x
Cable Sizing - Motor Starting Voltagex
Short-Circuit Duty - Single-Phase Systemsx
Short-Circuit Duty - Panel Systemsx
Short-Circuit Duty - UPS Systemsx
Data Exchange
Output Report Data Comparatorx
One-Line Diagram
Graphical Undo & Redox
Graphical Alignment Toolsx
Group Rotationx
Element Mirroring & Polarityx
Coloring Based on Voltage Levelx
Voltage Propagation (Single-Phase)x
User-Defined Symbol Textx
Analysis Modules
Load Flowx
Arc Flashx
Transient Stabilityx
Star Time Current Characteristicsx
Star Sequence-of-Operationx
Data Exchange
DataX - Basex
-
8/7/2019 Etap 60 New Features
4/244
One-Line Diagram
ETAP One-Line Diagram is a user-friendly interface for creating and managing the network database used forschematic network visualization. Using features such as the intelligent one-line diagram, multi-level nestingof sub-systems, multi-color symbols, interfaces for management of switching devices, and a unique multi-dimensional database you can interactively model, monitor, and manage the electrical network as well asexecute simulation scenarios and analyze their results in a simple and intuitive manner.
ETAP 6.0 adds an extensive list of new features to the intelligent one-line diagram, propelling day-to-day systemmodeling and design tasks to a new level of speed, ease, and accuracy than ever before.
Graphical Undo / RedoETAP One-Line Diagram manages unlimited graphical actions with the help of agraphical undo / redo feature also widely known as the Oops Command. Backtracksingle or multiple steps to correct mistakes or reverse the effect of the undo commandby using redo.
Simply move any element from one location to another, run any calculation study, andundo an action to view the previous results.
Features
Unlimited graphical undo / redo actionsx
Undo / Redo actions within composite networksx
Undo / Redo show / hide protective devicesx
Undo / Redo movement of any devicex
Undo / Redo moving, adding, or deleting a connectionx
Standard keyboard shortcuts (undo - Ctrl+Z, redo - Ctrl+Y)x
Extremely
Easy-to-Use
-
8/7/2019 Etap 60 New Features
5/245
One-Line Diagram
Graphical Alignment ToolsSelect a portion of the one-line diagram
and use any of the ten available alignmentfeatures to automatically arrange elements.
Group RotationSelect a group of elements and rotate in one-click.
Features
Straight & space alignment for loadsx
Branch alignmentx
Horizontal alignment (middle, top, bottom)x
Vertical alignment (left, center, right)x
Distribute spacing (horizontal, vertical)x
Intelligent alignment designed for electrical systemsx
Arrange Motor
ControlCenters in
One-Click
-
8/7/2019 Etap 60 New Features
6/246
One-Line Diagram
Theme ManagerTheme Manager allows you to create and recall templates for the graphical display of elements, connectors,annotations, results, alerts, and background colors on the one-line diagram. The ETAP One-Line Diagram cannow be automatically color coded based on nominal system voltages.
Features
Up to 20 user-defined voltage levels & colorsx
Instantly create or switch between multiple color schemes using theme templatesx
Set different themes for individual one-line diagramsx
Select a background color for the best contrast when viewing one-line diagrams, performingx
system studies, or real-time monitoringFlexible coloring for AC & DC elements, annotations, & composite networksx
Assign visible color codes to alerts, alarms, & warningsx
Easily differentiate between 1-phase, 2-phase, & 3-phase systemsx
Modify the element, grid, & background colors for specific presentationsx
-
8/7/2019 Etap 60 New Features
7/247
One-Line Diagram
Relay & Current Transformer MirroringMirror current transformer & connected relays with one-clickx
Current Transformer PolarityReverse current transformer polarity based onxdirectional settings
Set correct polarity for current sensing forxdifferential, directional, & reverse power relays
User-Defined Symbol Text
User-defined symbol text, size, & font stylex
Label protective relays with device functionxnumbers
Voltage PropagationIn addition to the existing voltage propagation onthree-phase networks, the voltage propagationis now capable of detecting single-phase
connections and propagating voltage throughsingle-phase two-wire and three-wire systemsas well as panel systems.
Intuitive
One-Line
Diagram
-
8/7/2019 Etap 60 New Features
8/248
Arc Flash Analysis
Enhance Personnel SafetyETAP 6.0 brings you new and enhanced capabilities which allow for faster and easierperformance of arc flash hazard analysis. Identify and analyze high risk arc flash areas
in your electrical system with greater flexibility by simulating various incident energymitigation methods.
Arc Flash is a completely integrated module that solves multiple scenarios todetermine worst case incident energy levels and it also produces professional reportsand high quality arc flash labels at a press of a button.
The Most
Comprehensive
Arc Flash Hazard
Assessment
Solution
Load Terminal Arc FaultETAP Arc Flash Analysis provides the flexibility to analyze hundreds of possible arc fault locations withoutthe need for additional buses. This simple One-Click & Fault performs arc fault analysis at load terminalswithout the need for terminal buses or nodes.
Produce detailed analysis reports for every faulted locationx
Automatically generate arc flash labels for every incoming main circuit breaker cubicle, load circuitx
breaker, & motor starter bucketAutomatically generate arc flash labels for every load terminal point including induction motors,xsynchronous motors, capacitor banks, & static loads
Evaluates incident energy for devices equipped with maintenance mode settingx
IEEE 1584a-2004 methodx
NFPA 70E-2000 & 2004 methodsx
Cubic box & open air calculationsx
Integrated with ANSI & IEC Short-Circuitx
Integrated with Star device coordinationx
-
8/7/2019 Etap 60 New Features
9/249
Arc Flash Analysis
Simulate Multiple
Arc Fault Locations
including Motor
Load Terminals
in One-Click
-
8/7/2019 Etap 60 New Features
10/2410
Arc Flash Analysis
Labels in Multiple LanguagesArc Flash analyses are quickly becoming
a requirement in many countries. ETAPhas a wide variety of professional qualitylabels in multiple languages.
Arc Flash labels can easily be printedto Brady Label printers, DuraLabelPro printers, or to high quality materialAvery Labels.
Automatically
Considers
Operating Zones
Automatically
Generate & Print
Arc Flash Labels in
English, Spanish,Portuguese,
& more...
Protective Device HandlingProtective device actions of differential relay, in-line overloadrelay, directional relay, and recloser have been includedin ETAP Arc Flash Analysis. Bus, feeder, and transformerdifferential relays are modeled to determine incident energyfor an internal arc fault while considering locations that maybe outside the protection zone.
Differential Relays
In-Line Overload Relays
Reclosers
Directional Relay
-
8/7/2019 Etap 60 New Features
11/2411
Arc Flash Analysis
Maintenance Mode SwitchSome trip units are equipped with maintenance mode switcheswhich allow for an alternative setting with a faster operationbased on a lower pickup value. ETAP Arc Flash reports incidentenergy under normal trip unit settings as well as maintenancemode settings.
Automatic Source & User-DefinedProtective Device Search AlgorithmThe automatic source and user-defined protectivedevice features have been significantly enhancedincluding:
Extended search of several levels past the pointxof multiple upstream source contributions
Handling of source protective devices on differentxsides of three-winding transformers
Simulate Zone Selective Interlocking (ZSI)xprotection scheme
Simulate Arc Flash Light Sensor operationx
-
8/7/2019 Etap 60 New Features
12/2412
UPS Systems
Panel Systems
Multi-Phase Systems
Short-Circuit Analysis
Single-Phase, Panel, & UPS Systems
Short-Circuit Device Duty Calculation & Evaluation ANSI / IECIn addition to 3-phase systems, the Short-Circuit Analysis module has been enhanced to include device dutycalculation and evaluation.
ANSI and IEC standards are available for calculating short circuit current for parts of the networkbelow main panels, sub panels, UPS, and phase adapters. Device duty calculation compares thecalculated fault current from these networks for evaluation of protective devices and automaticallygenerates critical and marginal alerts based on user-defined alarm limits.
-
8/7/2019 Etap 60 New Features
13/2413
Short-Circuit Analysis
Benefits of Equipment Cables for Loads
Eliminate the need for adding cables (load feeder) & load terminal buses to one-line diagramsx
Faster & easier system modelingx
Cleaner (less cluttered) one-line diagramsx
Reduce bus numbers (MCC with hundreds of loads is modeled with only one bus)x
Automatic cable sizing based on normal load, motor starting voltage drop, ampacity, & short circuitxrequirements
Display results of loading, voltage drop, & load terminal voltage based on bus or load rated voltage on one-linexdiagrams
Load Equipment Cables apply to induction motors, synchronous motors, capacitor banks, static loads, motorxoperated valves, & others with multiple quantities
Display & reporting of the load terminal fault currents under maximum, 1 - 4 cycle, & minimum conditionsxfor three-phase, double-phase, & single-phase loads on the one-line diagram
Load Terminal Fault Current ReportingShort-Circuit Analysis gives you the flexibility to analyze all possible fault locations within the same equipmentwithout the need for additional buses.
Setup time of the one-line diagram is dramatically
reduced by eliminating nodes used to represent everyfault location. This capability works seamlessly with theLoad Equipment Cable feature requiring fewer buses inyour ETAP license. This feature has virtually eliminatedthe need to insert nodes in the one-line diagram modelof motor control centers and large switchgear lineups.
Simulate Load
Terminal Faultsat Multiple
Locations with
One-Click
MCC with
Hundreds of
Loads is Modeled
with Only
One Bus
-
8/7/2019 Etap 60 New Features
14/2414
Graphical Animation of Protective Device OperationETAP 6.0 includes an extensive list of enhancements for the ETAP Star module. Using these new user-orientedcapabilities, the process of design and evaluation of protective device coordination is significantly faster and
easier. Among them is Star Sequence-of-Operation with new additions and enhanced handling of protectivedevices such as differential relay (87), directional relay (67), voltage restraint / control relay (51V), voltage relay(27), fault interrupter, and recloser (79).
Features
AC & DC coordinationx
Adjust device settings graphicallyx
Comprehensive Verified & Validated device librariesx
Embedded short circuit analysisx
Embedded motor acceleration analysisx
Integrated with one-line diagramx
Multi-axis time current curvesx
User-definable plot optionsx
Adjustable magnifying-glass zoom viewx
Time difference calculatorx
Multi-function / level relaysx
Customizable device setting reportsx
Intelligent device coordination & selectivityx
View device operation sequence graphicallyx
Device failure & backup operationx
User-definable curves & fault arrowsx
Virtual animation of sequence-of-operation playback on the one-line diagramx
Normalized TCC plots with shifted curves based on fault contributionsx
Batch print TCC plots & diagrams for various paper sizesx
Automated color sequencing of curvesx
Flexible user-definable display & plot optionsx
Intelligent alert view for troubleshootingx
Acceleration curve for overload relaysx
Extensive damage curve (fixed points) modeling & plottingx
Graphical TCC curve tracker with cross lines & time difference toolsx
Relay Test Set Interface for evaluating steady-state & transient relay responsex
The Most
Comprehensive
& Easiest
Protective DeviceCoordination
& Selectivity
Analysis Solution
Device Coordination
-
8/7/2019 Etap 60 New Features
15/2415
Generator Decrement CurveETAP provides plotting of the generatordecrement curve and display both the
symmetrical and asymmetrical decrementcurve based on generator no-load or full-loadconditions. Excitation system field forcingcapability, used to speed up the response of thegenerator, is also considered when plotting thegenerator decrement curve.
Multiple Motor Starting Curves
Based on Starting VoltageA motor starting curve can be plotted on a Star view for thepurpose of determining overload settings for motor protectiondevices. Constant Terminal Voltage can be used to plot the motorstarting curve based on a constant voltage at the motor terminal.
Motor Stator Damage CurveThe motor curves have been enhanced by including stator damage curve or runninoverload curve into ETAP Star. Stator curves can be plotted based on multiples ofmachine full-load amps or actual amp values.
Device Coordination
-
8/7/2019 Etap 60 New Features
16/2416
Recloser / Fault InterrupterHydraulic recloserx
Static controllerx
Microprocessor controllerx
Detailed modeling of reclosing devicex
Device coordination curvesx
ANSI / IEC short circuit duty evaluationx
Overload alerts in Load Flow Analysisx
Recloser libraryxController libraryx
Differential RelayTotal bus, transformer, line, & cablex
Percentage differential typesx
High impedance bus differentialx
Fault zone detectionx
Differential relay librariesx
One Action
Resulting in
a Complete
Solution
Device Coordination
-
8/7/2019 Etap 60 New Features
17/2417
In-Line Overload RelayDetailed modeling of in-line overloadx
Thermal, instantaneous, jam, & ground tripxelements
Integrated curvesx
In-line overload relay libraryx
SignificantlyFaster
&
Easier
Additional EnhancementsNewly added Verified & Validated device librariesx
Enhanced device setting reportsx
Batch print Star viewsx
Star Plot Option settingsx
Star TCC plot & reference voltage optionx
Device Coordination
-
8/7/2019 Etap 60 New Features
18/2418
Load Flow Analysis
Load Flow Result AnalyzerETAP Load Flow Result Analyzer is a
time-saving tool that compares andanalyzes multiple reports in a singleview. You can compare the results ofgeneral information about the projector more specific information suchas the load flow results for buses,branches, loads, or sources.
Features
Compare & view multiple load flow results in a single viewx
Analyze & compare reports from multiple projectsx
Create a base line report & quickly identify deviations for all casesx
View multiple bus, branch, load, & source resultsx
Advanced alert & warning feature identifies & highlights overstressed componentsx
Easily find components on one-line diagrams from the analyzer viewx
Export summary view into Microsoftx Excel for maximum data flexibility & visualization
Understand
Results of
Multiple
Studies in
One Glance
-
8/7/2019 Etap 60 New Features
19/2419
Transient Stability Analysis
Transient StabilityETAP 6.0 adds numerous capabilities to transient stability, making it the most powerful stability program inthe industry hands-down. Transient Stability module is also enhanced for faster calculation speed and plotgenerations. You can simulate system disturbances and events while performing load shedding, fast bus transfe
critical clearing time, generator start-up studies, and the acceleration or re-acceleration of motors.
Features
Initial load flow using the Newton-Raphson method in addition to the Accelerated Gauss Siedel methodx
Faster calculation time by skipping tabular plotsx
New transient simulation action line-to-ground faultx
New GE Turbine-Governor Model (GGOV3)x
New Exciter (IEEE ST4B)x
Auto sync-check option for tie circuit breaker closing actionx
Enhanced synchronous machine saturation curve modelingx
Enhanced synchronous machine salient-pole modelx
-
8/7/2019 Etap 60 New Features
20/2420
Cable Systems
Cable AmpacityWith the new addition of British Standard 7671, ETAP 6.0 now calculates the current carrying capacity of cablesunder various cable installations and operating conditions based on a number of standards:
IEEE 399 IEEE Recommended Practice for Industrial & Commercial Power Systems Analysisx
ICEA P-54-440 Ampacities of Cables in Open-Top Cable Trayx
NEC NFPA 70, National Electrical Codex
BS 7671 British Standard 7671 Requirements for Electrical Installationsx
Cable SizingETAP Cable Sizing provides various options which can be used as design requirements. These designrequirements can be user-defined or automatically determined from load flow, short circuit, and protectivedevice calculation results.
Cable load ampacity requirement based on operating current, FLA of load, branch, or user-defined valuesx
Maximum voltage drop requirementx
Minimum starting voltage requirement for motor feeder cablex
Short circuit requirement based on system calculationx
Requirement to be compatible with protective devicesx
A Powerful
&
Easy-to-Use
Tool
Ampacity
VoltageDrop
ShortCircuit
Motor StartVoltage
ProtectiveDevice
Cable Sizing Requirements
-
8/7/2019 Etap 60 New Features
21/2421
Cable Systems
Cable Installations
-
8/7/2019 Etap 60 New Features
22/2422
Data Exchange
Data ExchangeETAP Data Exchange is used to import, export, and synchronize data betweenexternal data sources and ETAP. DataX provides many utilities including:
Legacy data transformation into ETAPx
Interface with external architecture databasesx
Customizable data mappingx
Intelligent error checkingx
Automatic one-line diagram generationx
DataX includes several new conversion programs that allow for conversionof third party electrical power system databases to ETAP. The conversionprogram will automatically generate a multi-layered graphical one-linediagram. A list of available conversion programs are available upon request.
DataX Base
In addition to the standard data exchangecapabilities such as import IEEE and RAWdata formats, DataX has been enhanced toread SEQ and DYR file formats for importingunbalanced impedance data as well asdynamic data for transient stability studies.
Output Report Data ComparatorThe Output Report Data Comparator can be used to compare any two output report databases of ETAP analysismodules. This application interfaces with the Scenario Wizard allowing exhaustive comparison of output reportsfrom the latest version against a previously saved benchmark output report database. The benchmark results
could have been generated using a previous version or the same version of ETAP.
Features
Compare any ETAP output report databasex
Compare any Microsoftx Access database (MDB files)
Compare results of different ETAP releasesx
Flexible database instruction file with default settingsx
Available Command Line instructionx
Automatic validations with user-defined deviation limitx
Summary & detailed comparison with Pass / Fail stampingx
DXFx
Metafilex
XMLx
IEEE Formatx
RAW Formatx
MS Accessx
MS Excelx
e-DPPx
SmartPlant Electricalx
Third Party Programsx
-
8/7/2019 Etap 60 New Features
23/2423
ETAP Support
Keep Up-to-Date with ETAP Product UpdatesImproving and expanding our products is a continual process for theETAP development team. These ongoing product updates ensure thatETAP continues to not only meet, but exceed our customer requirements.
ETAP Upgrade & User-Support Contract (UUC)One of the best ways to get the most out of your software investment is tomaintain a current maintenance contract. This ensures that your powersystem design, simulation, and analysis is always based on the newest,most advanced technology available. ETAP UUC includes:
All upgrades & new releasesx
Unlimited software supportx
Unlimited engineering supportx
Access to the ETAP User FTP download sitex
Receive prerelease & beta versions of new product upgradesx
Full access to OTIs engineering expertise by your entire engineeringxstaff
FeedbackOperation Technology, Inc. is dedicated to providing our customers witha superior product experience, and user feedback is one of the centralelements of this commitment. In fact, ETAP is designed based on 95% ofuser suggestions and requests! Tell us how we are doing by:
Filling out a short survey at etap.com (click on User Feedback Form)x
E-mailing ETAP Technical Support at supportx @etap.com
Sharing your comments with your local ETAP AuthorizedxRepresentative
ETAP License OptionsTo meet the different needs of our varied customers, ETAP can bepurchased via three licensing options, each of which has been tailoredto meet specific customer needs. The newest license option is ETAPAdvantage, which meets the requirements for quality assurancedocumentation and performance reporting. Visit etap.com for more
details on the license options available.
Visit ETAP.comThe ETAP web site is your best resource for up-to-the minute informationabout ETAP products and services. The site includes the latest productupdate announcements, a worldwide training calendar, video tutorials,frequently asked questions, archived webinars, ETAP downloads, whitepapers and articles, information about ETAP User Groups, and muchmore. Click on the Request ETAP News link to receive periodic e-mailsinforming you of whats new in ETAP.
ETAP 6.0 System Requirement
Operating System
Microsoft Windows Vista
Microsoft Windows XP (SP2)Professional or Home Edition
Microsoft Server 2003 (SP2), MicrosoServer 2003 R2 (SP2)
Other Software Requirements
Microsoft Internet Explorer 5.01 orhigher (or minimum version level asspecified by the operating system in u
Microsoft .NET Framework v1.1 (SP1
Microsoft .NET Framework v2.0 (SP1
PC Configuration Requirements
Parallel port, USB port, or serial port stand-alone licensing only)
CD-ROM or DVD drive
5 to 80 GB hard disk space (based onproject size, number of buses)
19 monitors recommended (dualmonitors highly recommended)
Minimum display resolution 1024x76
Recommended Hardware Requiremen
500 Bus Projects:
Intel Pentium 4 2.0 GHz (or duaquad core E6600) or better
1 GB RAM
2000 Bus Projects:(Highly Recommended)
Intel Pentium 4 3.2 GHz with HyThreading Technology (or dual/quadcore - E6700) or better with high spebus or equivalent
2 GB of RAM (high speed)
10000 Bus Projects and Higher:
Intel Xeon 3.2 GHz with Hyper-Threading (or dual/quad core X680or better with high speed system buAMD equivalent
2 to 4 GB RAM (high speed)
-
8/7/2019 Etap 60 New Features
24/24
17 Goodyear, Suite 100 Irvine, CA 92618
(800) 477-ETAP (949) 462-0100 Fax (949) 462-0200