    ETAP Enterprise Solution

    ETAP is the most comprehensive analysis platform for the design,simulation, operation, control, optimization, and automation ofgeneration, transmission, distribution, and industrial power systems.

    ETAP offers a suite of fully integrated software solutions includingarc flash, load flow, short circuit, relay coordination, cable ampacity,transient stability, optimal power flow, and more. Its modularfunctionality can be tailored to fit the needs of any company, from smalto large power systems.

    Quality Assurance CommitmentETAP is Verified and Validated (V&V) against field results, real systemmeasurements, established programs, and hand calculations to ensureits technical accuracy. Each release of ETAP undergoes a complete V&Vprocess using thousands of test cases for each and every calculationmodule.

    One-Line Diagram ....................4

    Arc Flash Analysis ....................8

    Short-Circuit Analysis ............12

    Star - Device Coordination ..... 14

    Load Flow Analysis ................. 18

    Transient Stability Analysis .... 19

    Cable Systems ........................20

    Data Exchange ........................22

    ETAP Support ......................... 23

    System Requirements ............23

    ETAP Quality Assurance program is specificallydedicated to meeting the requirements of:

    ISO 9001:2000 A3147 UL10 CFR 50 Appendix B

    10 CFR 21ANSI/ASME N45.2

    ASME NQA-1ANSI/IEEE 730.1

    CAN/CSA-Q396.1.2ANSI N45.22

  • 8/7/2019 Etap 60 New Features

    3/243

    Whats New in ETAP 6.0

    ETAP 6.0 is a major release that incorporates a broad and robust set of new features and enhancementsincluding new analysis modules, time-saving capabilities as well as faster processing time, delivering

    an unmatched level of mathematical precision and professionalism. Many of the new and enhancedfunctionalities are based on user input and suggestions. These enhancements come to you as a part ofyour ETAP upgrade.

    Results You

    Can Trust

    Automated&

    Intelligent

    New FeaturesEnhanced Features

    Delivering Unmatched Speed, Precision, & Reliability

    Elements & Libraries

    Recloserx

    Differential Relayx

    In-Line Overload Relayx

    Maintenance Mode Settingx

    Analysis Modules

    Cable Ampacity - BS 7671x

    Cable Sizing - Motor Starting Voltagex

    Short-Circuit Duty - Single-Phase Systemsx

    Short-Circuit Duty - Panel Systemsx

    Short-Circuit Duty - UPS Systemsx

    Data Exchange

    Output Report Data Comparatorx

    One-Line Diagram

    Graphical Undo & Redox

    Graphical Alignment Toolsx

    Group Rotationx

    Element Mirroring & Polarityx

    Coloring Based on Voltage Levelx

    Voltage Propagation (Single-Phase)x

    User-Defined Symbol Textx

    Analysis Modules

    Load Flowx

    Arc Flashx

    Transient Stabilityx

    Star Time Current Characteristicsx

    Star Sequence-of-Operationx

    Data Exchange

    DataX - Basex

  • 8/7/2019 Etap 60 New Features

    4/244

    One-Line Diagram

    ETAP One-Line Diagram is a user-friendly interface for creating and managing the network database used forschematic network visualization. Using features such as the intelligent one-line diagram, multi-level nestingof sub-systems, multi-color symbols, interfaces for management of switching devices, and a unique multi-dimensional database you can interactively model, monitor, and manage the electrical network as well asexecute simulation scenarios and analyze their results in a simple and intuitive manner.

    ETAP 6.0 adds an extensive list of new features to the intelligent one-line diagram, propelling day-to-day systemmodeling and design tasks to a new level of speed, ease, and accuracy than ever before.

    Graphical Undo / RedoETAP One-Line Diagram manages unlimited graphical actions with the help of agraphical undo / redo feature also widely known as the Oops Command. Backtracksingle or multiple steps to correct mistakes or reverse the effect of the undo commandby using redo.

    Simply move any element from one location to another, run any calculation study, andundo an action to view the previous results.

    Features

    Unlimited graphical undo / redo actionsx

    Undo / Redo actions within composite networksx

    Undo / Redo show / hide protective devicesx

    Undo / Redo movement of any devicex

    Undo / Redo moving, adding, or deleting a connectionx

    Standard keyboard shortcuts (undo - Ctrl+Z, redo - Ctrl+Y)x

    Extremely

    Easy-to-Use

  • 8/7/2019 Etap 60 New Features

    5/245

    One-Line Diagram

    Graphical Alignment ToolsSelect a portion of the one-line diagram

    and use any of the ten available alignmentfeatures to automatically arrange elements.

    Group RotationSelect a group of elements and rotate in one-click.

    Features

    Straight & space alignment for loadsx

    Branch alignmentx

    Horizontal alignment (middle, top, bottom)x

    Vertical alignment (left, center, right)x

    Distribute spacing (horizontal, vertical)x

    Intelligent alignment designed for electrical systemsx

    Arrange Motor

    ControlCenters in

    One-Click

  • 8/7/2019 Etap 60 New Features

    6/246

    One-Line Diagram

    Theme ManagerTheme Manager allows you to create and recall templates for the graphical display of elements, connectors,annotations, results, alerts, and background colors on the one-line diagram. The ETAP One-Line Diagram cannow be automatically color coded based on nominal system voltages.

    Features

    Up to 20 user-defined voltage levels & colorsx

    Instantly create or switch between multiple color schemes using theme templatesx

    Set different themes for individual one-line diagramsx

    Select a background color for the best contrast when viewing one-line diagrams, performingx

    system studies, or real-time monitoringFlexible coloring for AC & DC elements, annotations, & composite networksx

    Assign visible color codes to alerts, alarms, & warningsx

    Easily differentiate between 1-phase, 2-phase, & 3-phase systemsx

    Modify the element, grid, & background colors for specific presentationsx

  • 8/7/2019 Etap 60 New Features

    7/247

    One-Line Diagram

    Relay & Current Transformer MirroringMirror current transformer & connected relays with one-clickx

    Current Transformer PolarityReverse current transformer polarity based onxdirectional settings

    Set correct polarity for current sensing forxdifferential, directional, & reverse power relays

    User-Defined Symbol Text

    User-defined symbol text, size, & font stylex

    Label protective relays with device functionxnumbers

    Voltage PropagationIn addition to the existing voltage propagation onthree-phase networks, the voltage propagationis now capable of detecting single-phase

    connections and propagating voltage throughsingle-phase two-wire and three-wire systemsas well as panel systems.

    Intuitive

    One-Line

    Diagram

  • 8/7/2019 Etap 60 New Features

    8/248

    Arc Flash Analysis

    Enhance Personnel SafetyETAP 6.0 brings you new and enhanced capabilities which allow for faster and easierperformance of arc flash hazard analysis. Identify and analyze high risk arc flash areas

    in your electrical system with greater flexibility by simulating various incident energymitigation methods.

    Arc Flash is a completely integrated module that solves multiple scenarios todetermine worst case incident energy levels and it also produces professional reportsand high quality arc flash labels at a press of a button.

    The Most

    Comprehensive

    Arc Flash Hazard

    Assessment

    Solution

    Load Terminal Arc FaultETAP Arc Flash Analysis provides the flexibility to analyze hundreds of possible arc fault locations withoutthe need for additional buses. This simple One-Click & Fault performs arc fault analysis at load terminalswithout the need for terminal buses or nodes.

    Produce detailed analysis reports for every faulted locationx

    Automatically generate arc flash labels for every incoming main circuit breaker cubicle, load circuitx

    breaker, & motor starter bucketAutomatically generate arc flash labels for every load terminal point including induction motors,xsynchronous motors, capacitor banks, & static loads

    Evaluates incident energy for devices equipped with maintenance mode settingx

    IEEE 1584a-2004 methodx

    NFPA 70E-2000 & 2004 methodsx

    Cubic box & open air calculationsx

    Integrated with ANSI & IEC Short-Circuitx

    Integrated with Star device coordinationx

  • 8/7/2019 Etap 60 New Features

    9/249

    Arc Flash Analysis

    Simulate Multiple

    Arc Fault Locations

    including Motor

    Load Terminals

    in One-Click

  • 8/7/2019 Etap 60 New Features

    10/2410

    Arc Flash Analysis

    Labels in Multiple LanguagesArc Flash analyses are quickly becoming

    a requirement in many countries. ETAPhas a wide variety of professional qualitylabels in multiple languages.

    Arc Flash labels can easily be printedto Brady Label printers, DuraLabelPro printers, or to high quality materialAvery Labels.

    Automatically

    Considers

    Operating Zones

    Automatically

    Generate & Print

    Arc Flash Labels in

    English, Spanish,Portuguese,

    & more...

    Protective Device HandlingProtective device actions of differential relay, in-line overloadrelay, directional relay, and recloser have been includedin ETAP Arc Flash Analysis. Bus, feeder, and transformerdifferential relays are modeled to determine incident energyfor an internal arc fault while considering locations that maybe outside the protection zone.

    Differential Relays

    In-Line Overload Relays

    Reclosers

    Directional Relay

  • 8/7/2019 Etap 60 New Features

    11/2411

    Arc Flash Analysis

    Maintenance Mode SwitchSome trip units are equipped with maintenance mode switcheswhich allow for an alternative setting with a faster operationbased on a lower pickup value. ETAP Arc Flash reports incidentenergy under normal trip unit settings as well as maintenancemode settings.

    Automatic Source & User-DefinedProtective Device Search AlgorithmThe automatic source and user-defined protectivedevice features have been significantly enhancedincluding:

    Extended search of several levels past the pointxof multiple upstream source contributions

    Handling of source protective devices on differentxsides of three-winding transformers

    Simulate Zone Selective Interlocking (ZSI)xprotection scheme

    Simulate Arc Flash Light Sensor operationx

  • 8/7/2019 Etap 60 New Features

    12/2412

    UPS Systems

    Panel Systems

    Multi-Phase Systems

    Short-Circuit Analysis

    Single-Phase, Panel, & UPS Systems

    Short-Circuit Device Duty Calculation & Evaluation ANSI / IECIn addition to 3-phase systems, the Short-Circuit Analysis module has been enhanced to include device dutycalculation and evaluation.

    ANSI and IEC standards are available for calculating short circuit current for parts of the networkbelow main panels, sub panels, UPS, and phase adapters. Device duty calculation compares thecalculated fault current from these networks for evaluation of protective devices and automaticallygenerates critical and marginal alerts based on user-defined alarm limits.

  • 8/7/2019 Etap 60 New Features

    13/2413

    Short-Circuit Analysis

    Benefits of Equipment Cables for Loads

    Eliminate the need for adding cables (load feeder) & load terminal buses to one-line diagramsx

    Faster & easier system modelingx

    Cleaner (less cluttered) one-line diagramsx

    Reduce bus numbers (MCC with hundreds of loads is modeled with only one bus)x

    Automatic cable sizing based on normal load, motor starting voltage drop, ampacity, & short circuitxrequirements

    Display results of loading, voltage drop, & load terminal voltage based on bus or load rated voltage on one-linexdiagrams

    Load Equipment Cables apply to induction motors, synchronous motors, capacitor banks, static loads, motorxoperated valves, & others with multiple quantities

    Display & reporting of the load terminal fault currents under maximum, 1 - 4 cycle, & minimum conditionsxfor three-phase, double-phase, & single-phase loads on the one-line diagram

    Load Terminal Fault Current ReportingShort-Circuit Analysis gives you the flexibility to analyze all possible fault locations within the same equipmentwithout the need for additional buses.

    Setup time of the one-line diagram is dramatically

    reduced by eliminating nodes used to represent everyfault location. This capability works seamlessly with theLoad Equipment Cable feature requiring fewer buses inyour ETAP license. This feature has virtually eliminatedthe need to insert nodes in the one-line diagram modelof motor control centers and large switchgear lineups.

    Simulate Load

    Terminal Faultsat Multiple

    Locations with

    One-Click

    MCC with

    Hundreds of

    Loads is Modeled

    with Only

    One Bus

  • 8/7/2019 Etap 60 New Features

    14/2414

    Graphical Animation of Protective Device OperationETAP 6.0 includes an extensive list of enhancements for the ETAP Star module. Using these new user-orientedcapabilities, the process of design and evaluation of protective device coordination is significantly faster and

    easier. Among them is Star Sequence-of-Operation with new additions and enhanced handling of protectivedevices such as differential relay (87), directional relay (67), voltage restraint / control relay (51V), voltage relay(27), fault interrupter, and recloser (79).

    Features

    AC & DC coordinationx

    Adjust device settings graphicallyx

    Comprehensive Verified & Validated device librariesx

    Embedded short circuit analysisx

    Embedded motor acceleration analysisx

    Integrated with one-line diagramx

    Multi-axis time current curvesx

    User-definable plot optionsx

    Adjustable magnifying-glass zoom viewx

    Time difference calculatorx

    Multi-function / level relaysx

    Customizable device setting reportsx

    Intelligent device coordination & selectivityx

    View device operation sequence graphicallyx

    Device failure & backup operationx

    User-definable curves & fault arrowsx

    Virtual animation of sequence-of-operation playback on the one-line diagramx

    Normalized TCC plots with shifted curves based on fault contributionsx

    Batch print TCC plots & diagrams for various paper sizesx

    Automated color sequencing of curvesx

    Flexible user-definable display & plot optionsx

    Intelligent alert view for troubleshootingx

    Acceleration curve for overload relaysx

    Extensive damage curve (fixed points) modeling & plottingx

    Graphical TCC curve tracker with cross lines & time difference toolsx

    Relay Test Set Interface for evaluating steady-state & transient relay responsex

    The Most

    Comprehensive

    & Easiest

    Protective DeviceCoordination

    & Selectivity

    Analysis Solution

    Device Coordination

  • 8/7/2019 Etap 60 New Features

    15/2415

    Generator Decrement CurveETAP provides plotting of the generatordecrement curve and display both the

    symmetrical and asymmetrical decrementcurve based on generator no-load or full-loadconditions. Excitation system field forcingcapability, used to speed up the response of thegenerator, is also considered when plotting thegenerator decrement curve.

    Multiple Motor Starting Curves

    Based on Starting VoltageA motor starting curve can be plotted on a Star view for thepurpose of determining overload settings for motor protectiondevices. Constant Terminal Voltage can be used to plot the motorstarting curve based on a constant voltage at the motor terminal.

    Motor Stator Damage CurveThe motor curves have been enhanced by including stator damage curve or runninoverload curve into ETAP Star. Stator curves can be plotted based on multiples ofmachine full-load amps or actual amp values.

    Device Coordination

  • 8/7/2019 Etap 60 New Features

    16/2416

    Recloser / Fault InterrupterHydraulic recloserx

    Static controllerx

    Microprocessor controllerx

    Detailed modeling of reclosing devicex

    Device coordination curvesx

    ANSI / IEC short circuit duty evaluationx

    Overload alerts in Load Flow Analysisx

    Recloser libraryxController libraryx

    Differential RelayTotal bus, transformer, line, & cablex

    Percentage differential typesx

    High impedance bus differentialx

    Fault zone detectionx

    Differential relay librariesx

    One Action

    Resulting in

    a Complete

    Solution

    Device Coordination

  • 8/7/2019 Etap 60 New Features

    17/2417

    In-Line Overload RelayDetailed modeling of in-line overloadx

    Thermal, instantaneous, jam, & ground tripxelements

    Integrated curvesx

    In-line overload relay libraryx

    SignificantlyFaster

    &

    Easier

    Additional EnhancementsNewly added Verified & Validated device librariesx

    Enhanced device setting reportsx

    Batch print Star viewsx

    Star Plot Option settingsx

    Star TCC plot & reference voltage optionx

    Device Coordination

  • 8/7/2019 Etap 60 New Features

    18/2418

    Load Flow Analysis

    Load Flow Result AnalyzerETAP Load Flow Result Analyzer is a

    time-saving tool that compares andanalyzes multiple reports in a singleview. You can compare the results ofgeneral information about the projector more specific information suchas the load flow results for buses,branches, loads, or sources.

    Features

    Compare & view multiple load flow results in a single viewx

    Analyze & compare reports from multiple projectsx

    Create a base line report & quickly identify deviations for all casesx

    View multiple bus, branch, load, & source resultsx

    Advanced alert & warning feature identifies & highlights overstressed componentsx

    Easily find components on one-line diagrams from the analyzer viewx

    Export summary view into Microsoftx Excel for maximum data flexibility & visualization

    Understand

    Results of

    Multiple

    Studies in

    One Glance

  • 8/7/2019 Etap 60 New Features

    19/2419

    Transient Stability Analysis

    Transient StabilityETAP 6.0 adds numerous capabilities to transient stability, making it the most powerful stability program inthe industry hands-down. Transient Stability module is also enhanced for faster calculation speed and plotgenerations. You can simulate system disturbances and events while performing load shedding, fast bus transfe

    critical clearing time, generator start-up studies, and the acceleration or re-acceleration of motors.

    Features

    Initial load flow using the Newton-Raphson method in addition to the Accelerated Gauss Siedel methodx

    Faster calculation time by skipping tabular plotsx

    New transient simulation action line-to-ground faultx

    New GE Turbine-Governor Model (GGOV3)x

    New Exciter (IEEE ST4B)x

    Auto sync-check option for tie circuit breaker closing actionx

    Enhanced synchronous machine saturation curve modelingx

    Enhanced synchronous machine salient-pole modelx

  • 8/7/2019 Etap 60 New Features

    20/2420

    Cable Systems

    Cable AmpacityWith the new addition of British Standard 7671, ETAP 6.0 now calculates the current carrying capacity of cablesunder various cable installations and operating conditions based on a number of standards:

    IEEE 399 IEEE Recommended Practice for Industrial & Commercial Power Systems Analysisx

    ICEA P-54-440 Ampacities of Cables in Open-Top Cable Trayx

    NEC NFPA 70, National Electrical Codex

    BS 7671 British Standard 7671 Requirements for Electrical Installationsx

    Cable SizingETAP Cable Sizing provides various options which can be used as design requirements. These designrequirements can be user-defined or automatically determined from load flow, short circuit, and protectivedevice calculation results.

    Cable load ampacity requirement based on operating current, FLA of load, branch, or user-defined valuesx

    Maximum voltage drop requirementx

    Minimum starting voltage requirement for motor feeder cablex

    Short circuit requirement based on system calculationx

    Requirement to be compatible with protective devicesx

    A Powerful

    &

    Easy-to-Use

    Tool

    Ampacity

    VoltageDrop

    ShortCircuit

    Motor StartVoltage

    ProtectiveDevice

    Cable Sizing Requirements

  • 8/7/2019 Etap 60 New Features

    21/2421

    Cable Systems

    Cable Installations

  • 8/7/2019 Etap 60 New Features

    22/2422

    Data Exchange

    Data ExchangeETAP Data Exchange is used to import, export, and synchronize data betweenexternal data sources and ETAP. DataX provides many utilities including:

    Legacy data transformation into ETAPx

    Interface with external architecture databasesx

    Customizable data mappingx

    Intelligent error checkingx

    Automatic one-line diagram generationx

    DataX includes several new conversion programs that allow for conversionof third party electrical power system databases to ETAP. The conversionprogram will automatically generate a multi-layered graphical one-linediagram. A list of available conversion programs are available upon request.

    DataX Base

    In addition to the standard data exchangecapabilities such as import IEEE and RAWdata formats, DataX has been enhanced toread SEQ and DYR file formats for importingunbalanced impedance data as well asdynamic data for transient stability studies.

    Output Report Data ComparatorThe Output Report Data Comparator can be used to compare any two output report databases of ETAP analysismodules. This application interfaces with the Scenario Wizard allowing exhaustive comparison of output reportsfrom the latest version against a previously saved benchmark output report database. The benchmark results

    could have been generated using a previous version or the same version of ETAP.

    Features

    Compare any ETAP output report databasex

    Compare any Microsoftx Access database (MDB files)

    Compare results of different ETAP releasesx

    Flexible database instruction file with default settingsx

    Available Command Line instructionx

    Automatic validations with user-defined deviation limitx

    Summary & detailed comparison with Pass / Fail stampingx

    DXFx

    Metafilex

    XMLx

    IEEE Formatx

    RAW Formatx

    MS Accessx

    MS Excelx

    e-DPPx

    SmartPlant Electricalx

    Third Party Programsx

  • 8/7/2019 Etap 60 New Features

    23/2423

    ETAP Support

    Keep Up-to-Date with ETAP Product UpdatesImproving and expanding our products is a continual process for theETAP development team. These ongoing product updates ensure thatETAP continues to not only meet, but exceed our customer requirements.

    ETAP Upgrade & User-Support Contract (UUC)One of the best ways to get the most out of your software investment is tomaintain a current maintenance contract. This ensures that your powersystem design, simulation, and analysis is always based on the newest,most advanced technology available. ETAP UUC includes:

    All upgrades & new releasesx

    Unlimited software supportx

    Unlimited engineering supportx

    Access to the ETAP User FTP download sitex

    Receive prerelease & beta versions of new product upgradesx

    Full access to OTIs engineering expertise by your entire engineeringxstaff

    FeedbackOperation Technology, Inc. is dedicated to providing our customers witha superior product experience, and user feedback is one of the centralelements of this commitment. In fact, ETAP is designed based on 95% ofuser suggestions and requests! Tell us how we are doing by:

    Filling out a short survey at etap.com (click on User Feedback Form)x

    E-mailing ETAP Technical Support at supportx @etap.com

    Sharing your comments with your local ETAP AuthorizedxRepresentative

    ETAP License OptionsTo meet the different needs of our varied customers, ETAP can bepurchased via three licensing options, each of which has been tailoredto meet specific customer needs. The newest license option is ETAPAdvantage, which meets the requirements for quality assurancedocumentation and performance reporting. Visit etap.com for more

    details on the license options available.

    Visit ETAP.comThe ETAP web site is your best resource for up-to-the minute informationabout ETAP products and services. The site includes the latest productupdate announcements, a worldwide training calendar, video tutorials,frequently asked questions, archived webinars, ETAP downloads, whitepapers and articles, information about ETAP User Groups, and muchmore. Click on the Request ETAP News link to receive periodic e-mailsinforming you of whats new in ETAP.

    ETAP 6.0 System Requirement

    Operating System

    Microsoft Windows Vista

    Microsoft Windows XP (SP2)Professional or Home Edition

    Microsoft Server 2003 (SP2), MicrosoServer 2003 R2 (SP2)

    Other Software Requirements

    Microsoft Internet Explorer 5.01 orhigher (or minimum version level asspecified by the operating system in u

    Microsoft .NET Framework v1.1 (SP1

    Microsoft .NET Framework v2.0 (SP1

    PC Configuration Requirements

    Parallel port, USB port, or serial port stand-alone licensing only)

    CD-ROM or DVD drive

    5 to 80 GB hard disk space (based onproject size, number of buses)

    19 monitors recommended (dualmonitors highly recommended)

    Minimum display resolution 1024x76

    Recommended Hardware Requiremen

    500 Bus Projects:

    Intel Pentium 4 2.0 GHz (or duaquad core E6600) or better

    1 GB RAM

    2000 Bus Projects:(Highly Recommended)

    Intel Pentium 4 3.2 GHz with HyThreading Technology (or dual/quadcore - E6700) or better with high spebus or equivalent

    2 GB of RAM (high speed)

    10000 Bus Projects and Higher:

    Intel Xeon 3.2 GHz with Hyper-Threading (or dual/quad core X680or better with high speed system buAMD equivalent

    2 to 4 GB RAM (high speed)

  • 8/7/2019 Etap 60 New Features

    24/24

    17 Goodyear, Suite 100 Irvine, CA 92618

    (800) 477-ETAP (949) 462-0100 Fax (949) 462-0200

    OperatiOn technOlOgy, inc.

    http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/http://etap.com/