eul parameters
DESCRIPTION
Eul ParametersTRANSCRIPT
Parameter Name Value Range
Default Value
Recom- mended Value
Resolution
Unit
The EUL SchedulereulTargetRate 0 – 6016 160 128 (The
internal maximum limit is 416, and is quantized to 640 for 2 ms TTI users)
32 kbps
eulNoReschUsers 0 – 32 5 1 EUL user
eulMaxNoSchEdch 0 – 100 100 See Section 6
1 EUL user
eulNoERgchGroups 1 – 16 4 16 1 E-RGCH group
eulMaxShoRate 0 – 6016 5760 5760 32 kbpseulNonServHwRate 0 – 5760 160 128 32 kbpseulSchedulingWeight[16] 0-16 1 1 NAeulLowRate 0 – 6016 32 32
Note: this parameter should not be set to zero
32 kbps
eulMaxAllowedSchRate 0 – 6016 3968 IF IS feature is on, then 5120, If GRAKE feature is on and IS is OFF then 4480, otherwise (IS OFF, GRAKE OFF) if RAKE receiver applies then 3968
32 kbps
eul2msFirstSchedStep 20 - 160 160 160 N/A kbpseulTdSchedulingFactor 0..15 0 0 1 N/A
Note that this value means that EUL CDM and EUL TD scheduled users will be treated equally.
eulMaxTdUsers 2..8 8 8 1 N/AeulDchMaxAllowedSchRate 0..3200 1600 1600 32 1
kbps
The UL Uu Load EstimatoreulThermalLevelPrior -1150...-600 -1040 1 0.1
dBmeulSlidingWindowTime 10...864000 1800 72000 10 seulMinMarginCoverage 0...100 10 10 2 0.01
dBeulNoiseFloorLock True, False False - -eulOptimalNoiseFloorEstimate -1150 – -
600, -1-1040 1 0.1
dBmeulMaxRotCoverage 0...550 100 1 0.1
dBeulMaxOwnUuLoad 0...550 30 80 1 0.1
dBeulMaxTargetRtwp -1120..-499 -499 1 0.1
dB
CE Extension for EULeulLowUsageTime 10..1000 400 1 1 ms