events wcdma-rough sheet

2
 1a-1I(Intrafreq reporting events( 1a to 1f FDD & 1g to 1I TDD) 2a-2f inter-freq 3a-3d inter-rat 4a-4b traffic volume 5a- quality reporting events 6a-6e UE internal msrmnt reporting events 7A-7C UE positioning reporting events 1-Events =============== FDD 1a-A primary CPICH enters reporting range( addition of a cell to AS). 1b- A primary cpich leaves the reporting range(removal of cell from AS). 1c-A non-active primary cpich becomes betterthan active primary cpich(replacemnt  of a cell within the AS). 1d-change of best cell in AS. 1e-a primary CPICH becomes better tha an absolute threshold 1f-a primary CPICH becomes worse than an absolute threshold TDD 1g-Change best cell in TDD 1h-DL timeslot ISCP is below a certain threshold 1I-DL timeslot ISCP aboev a certain threshold ==================== 2a-change best freq 2b-estimated quality of currently used freq is below certains threshold and esti mated quality of non used frew is above certain threshold 2c- estimated quality of non used freq is bettaethan certain threshold 2d-estimated quality of currently used freq is below certains threshold(start co mpressmode) 2e- estimated quality of non used freq is below than certain threshold 2f-estimated quality of currently used freq is above certains threshold(start co mpressmode) ===================== 3a-estimated quality of currently used system is below certain threshold and est imated quality of other system is above certain threshold(i-RAT HO0 3b-estimated quality of other system is below certain threshold 3c-estimated quality of other system is above certain threshold 3d-change of best cell ================== 4a-traffic volume is exceed the abosulte threshold 4b-traffic volume is below the absolute threshold ===================== 5a-the predefined no of bad CRC exceeded the ========================== 6a-the UE Tx power is exceeded certain threshold(start compress mode) 6b-the UE Tx power is below certain threshold(end compress mode) 6c-the UE Tx power is minimum 6b-the UE xt power is maximum 6e-the noise UE dynamic receiver range ===================== 7a-UE position changes more than an absolute threshold 7b-SFN-SFN

Upload: naveen-vengaldas

Post on 14-Jan-2016

213 views

Category:

Documents


0 download

DESCRIPTION

events_3G

TRANSCRIPT

7/18/2019 Events Wcdma-rough Sheet

http://slidepdf.com/reader/full/events-wcdma-rough-sheet 1/1

1a-1I(Intrafreq reporting events( 1a to 1f FDD & 1g to 1I TDD)2a-2f inter-freq3a-3d inter-rat4a-4b traffic volume5a- quality reporting events6a-6e UE internal msrmnt reporting events7A-7C UE positioning reporting events

1-Events===============FDD1a-A primary CPICH enters reporting range( addition of a cell to AS).1b- A primary cpich leaves the reporting range(removal of cell from AS).1c-A non-active primary cpich becomes betterthan active primary cpich(replacemnt of a cell within the AS).1d-change of best cell in AS.1e-a primary CPICH becomes better tha an absolute threshold1f-a primary CPICH becomes worse than an absolute thresholdTDD1g-Change best cell in TDD1h-DL timeslot ISCP is below a certain threshold1I-DL timeslot ISCP aboev a certain threshold====================2a-change best freq

2b-estimated quality of currently used freq is below certains threshold and estimated quality of non used frew is above certain threshold2c- estimated quality of non used freq is bettaethan certain threshold2d-estimated quality of currently used freq is below certains threshold(start compressmode)2e- estimated quality of non used freq is below than certain threshold2f-estimated quality of currently used freq is above certains threshold(start compressmode)=====================3a-estimated quality of currently used system is below certain threshold and estimated quality of other system is above certain threshold(i-RAT HO03b-estimated quality of other system is below certain threshold3c-estimated quality of other system is above certain threshold

3d-change of best cell==================4a-traffic volume is exceed the abosulte threshold4b-traffic volume is below the absolute threshold=====================5a-the predefined no of bad CRC exceeded the==========================6a-the UE Tx power is exceeded certain threshold(start compress mode)6b-the UE Tx power is below certain threshold(end compress mode)6c-the UE Tx power is minimum6b-the UE xt power is maximum6e-the noise UE dynamic receiver range=====================

7a-UE position changes more than an absolute threshold7b-SFN-SFN