evergreen family & womens health · evergreen family & womens health 1937 west harvard...

28
121 Lawrence Street, Eugene, OR 97401 | p: 541.342.5777 f: 541.342.6128 | www.2-form.com one people + one environment = 2 form architecture EVERGREEN FAMILY & WOMENS HEALTH 1937 West Harvard Roseburg OR 97471 ADDENDUM #1 Date Issued: April 4 2019 THIS ADDENDUM MODIFIES THE BIDDING DOCUMENTS FOR THE ABOVE PROJECT TO THE EXTENT INDICATED HEREIN AND ALL PORTIONS OF THE DOCUMENTS NOT SPECIFICALLY AFFECTED BY THIS AMENDMENT SHALL REMAIN IN FULL FORCE AND EFFECT. ALL ADDENDUM ITEMS SHALL BE ADDED TO AND FORM A PART OF THE BIDDING DOCUMENTS. SOME OF THE FOLLOWING CHANGES, NOTED BELOW, HAVE ALREADY BEEN INCLUDED IN THE BID SET OF DOCUMENTS. ________________ ARCHITECTURAL SPECIFICATIONS 1. Door hardware schedule has been added to section 08 71 00 of the Project Manual 2. Division 20 has been deleted from the table of contents in the Project Manual 3. Specification sections 32-33-01 (Site Furnishing – Benches) 32-33-02 (Site Furnishing – Trash and Litter Receptacles) & 32-33-03 (Site Furnishing – Bike Racks) Have been added to the project manual 4. Oak doors are to have a clear factory finish 5. AD exam slide doors are to match interior oak doors, Section 08-34-00 (Special Function Doors) has been added to the project manual. ARCHITECTURAL DRAWINGS 1. The countertop illustrated in elevation 10/A401 & 1/A101 is to be SS-1 2. Doors labeled as type “K” on sheet A105 are to be type “N’ 3. Wall type 3B will be changed to 3. The assembly has been updated to indicate that in some cases the plywood in the wall is existing and in other cases it will be new plywood. 4. In wall type 5, 25 gauge horizontal furring is to be changed to RC channel ADDENDUM ATTACHMENTS 1. Door hardware schedule to be inserted into spec Section 08 71 00 in the Project Manual 2. Site furnishing spec. Sections 32-33-01, 32-33-02 & 32-33-03 to be inserted in to Project Manual 3. Sheet A101, updated to include countertop tag 4. Sheet A105, with updated door types 5. Sheet A104, with updated wall types 6. Special Function Door Specification Section 08-34-00 to be inserted into project manual END ADDENDUM #1

Upload: others

Post on 20-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

121 Lawrence Street, Eugene, OR 97401 | p: 541.342.5777 f: 541.342.6128 | www.2-form.com

one people + one environment = 2 form architecture

EVERGREEN FAMILY & WOMENS HEALTH 1937 West Harvard

Roseburg OR 97471

ADDENDUM #1 Date Issued: April 4 2019

THIS ADDENDUM MODIFIES THE BIDDING DOCUMENTS FOR THE ABOVE PROJECT TO THE EXTENT INDICATED

HEREIN AND ALL PORTIONS OF THE DOCUMENTS NOT SPECIFICALLY AFFECTED BY THIS AMENDMENT SHALL

REMAIN IN FULL FORCE AND EFFECT. ALL ADDENDUM ITEMS SHALL BE ADDED TO AND FORM A PART OF THE

BIDDING DOCUMENTS.

SOME OF THE FOLLOWING CHANGES, NOTED BELOW, HAVE ALREADY BEEN INCLUDED IN THE BID SET OF

DOCUMENTS.

________________

ARCHITECTURAL SPECIFICATIONS 1. Door hardware schedule has been added to section 08 71 00 of the Project Manual

2. Division 20 has been deleted from the table of contents in the Project Manual

3. Specification sections 32-33-01 (Site Furnishing – Benches) 32-33-02 (Site Furnishing – Trash and Litter

Receptacles) & 32-33-03 (Site Furnishing – Bike Racks) Have been added to the project manual

4. Oak doors are to have a clear factory finish

5. AD exam slide doors are to match interior oak doors, Section 08-34-00 (Special Function Doors) has been

added to the project manual.

ARCHITECTURAL DRAWINGS 1. The countertop illustrated in elevation 10/A401 & 1/A101 is to be SS-1

2. Doors labeled as type “K” on sheet A105 are to be type “N’

3. Wall type 3B will be changed to 3. The assembly has been updated to indicate that in some cases the plywood

in the wall is existing and in other cases it will be new plywood.

4. In wall type 5, 25 gauge horizontal furring is to be changed to RC channel

ADDENDUM ATTACHMENTS

1. Door hardware schedule to be inserted into spec Section 08 71 00 in the Project Manual

2. Site furnishing spec. Sections 32-33-01, 32-33-02 & 32-33-03 to be inserted in to Project Manual

3. Sheet A101, updated to include countertop tag

4. Sheet A105, with updated door types

5. Sheet A104, with updated wall types

6. Special Function Door Specification Section 08-34-00 to be inserted into project manual

END ADDENDUM #1

Page 2: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 1 of 7

Manufacturer List CR Corbin Russwin HS HES MC McKinney NO Norton PE Pemko RO Rockwood SN Securitron Finish List 26D Satin Chrome 32D Satin Stainless Steel 626 Satin Chromium Plated 630 Satin Stainless Steel 689 Aluminum Painted CLEAR Clear US26D Chromium Plated, Dull US32D Stainless Steel, Dull Hardware Sets SET #1.0 - Aluminum Storefront Entrance Doors

• Doors: 101A 2 Continuous Hinge K-MCK-12HD 83” x SER12 CLEAR MC 1 Exit Device ED4800M x K157 x 6P x L4 x M110 x M92 x MELR x MK 630 CR 1 Exit Device ED4800M x M110 x M92 630 CR 2 Door Pull RM3300 48" OA. CTC TYPE 12XHD FASTENING US32D RO 1 Closer UNI-7500 689 NO 1 PowerMatic Operator 6060 D 689 NO 1 Drop Plate 7788 689 NO 1 Door Switch 505 NO 1 Power Supply AQD2 SN 2 ElectroLynx Harness QC-C012P MC 1 Vestibule Switch 504 NO

- NOTE: Balance of Hardware to be Supplied by Aluminum Storefront Supplier. Card Reader and Door Position Indicator are to be furnished by Owner/Security Contractor. Request to Exit (REX) in the form of Touchbar Monitoring is included in the Exit Device's Touch Pad. Wiring and coordination by others.

Page 3: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 2 of 7

SET #2.0 - Interior Aluminum Vestibule Door

• Doors: 101B 2 Continuous Hinge K-MCK-12HD 83” CLEAR MC 2 Dummy Bar ED5000DB 630 CR 2 Door Pull RM3300 48" OA. CTC TYPE 12XHD FASTENING US32D RO 1 Closer UNI-7500 689 NO 1 PowerMatic Operator 6060 D 689 NO 1 Drop Plate 7788 689 NO 1 Door Switch 505 NO

- NOTE: Balance of Hardware by Aluminum Storefront Supplier. SET #3.0 - Exterior Exit Pair

• Doors: 148A 2 Continuous Hinge K-MCK-12HD 95” x SER12 CLEAR MC 1 Exit Device ED4800MA x K157 x 6P x L4 x M110 x M92 x MELR x MK 630 CR 1 Exit Device ED4800MA x M110 x M92 630 CR 2 Door Pull RM3300 48" OA. CTC TYPE 12XHD FASTENING US32D RO 2 PowerMatic Operator 6060 D 689 NO 2 Door Switch 505 NO 1 Power Supply AQD2 SN 2 ElectroLynx Harness QC-C012P MC

- NOTE: Balance of Hardware by Aluminum Storefront Supplier. Card Reader and Door Position Indicator are to be furnished by Owner/Security Contractor. Request to Exit (REX) in the form of Touchbar Monitoring is included in the Exit Device's Touch Pad. Wiring and coordination by others.

SET #4.0 - Exterior HM Exit Doors with Latch Retraction

• Doors: 155C, 156, S1 2 Hinges T4A3386 4 1/2 X 4 1/2 NRP 32D MC 1 Electric Hinge T4A3386 4 1/2 X 4 1/2 QC12 32D MC 1 Exit Device ED5200 x PR959 x 6P x L4 x M110 x M92 x MELR x MK 630 CR 1 Closer UNI-7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Power Supply AQD2 SN 1 ElectroLynx Harness QC-C012P MC 1 Smoke Seal PK 55 BL 17' PE 1 Raindrip 346 C 40" PE 1 Door Bottom 345 AV 36" PE 1 Threshold 2727 A 36" WSLS10 PE

- NOTE: Card Reader and Door Position Indicator are to be furnished by Owner/Security Contractor. Request to Exit (REX) in the form of Touchbar Monitoring is included in the Exit Device's Touch Pad. Wiring and coordination by others.

Page 4: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 3 of 7

SET #5.0 - Shower Doors

• Doors: 163A, 165A 3 Hinges T4A3386 4 1/2 X 4 1/2 NRP 32D MC 1 Privacy Set ML2030 PSA x M19VN x SA114 626 CR 1 Emergency Key 398F438 N/A CRPT 1 Closer PR7500 SRI 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #6.0 - Exterior Storage Room Doors

• Doors: 152, 154, 265B, M1 3 Hinges T4A3386 4 1/2 X 4 1/2 NRP 32D MC 1 Lockset ML2059 PSA x L4 x MK x SA114 630 CR 1 Closer UNI-7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Smoke Seal PK 55 BL 17' PE 1 Raindrip 346 C 40" PE 1 Door Bottom 345 AV 36" PE 1 Threshold 2727 A 36" WSLS10 PE SET #7.0 - Exterior Receiving Man Door

• Doors: 153A 3 Hinges T4A3386 4 1/2 X 4 1/2 NRP 32D MC 1 Lockset ML2059 PSA x L4 x MK x SA114 630 CR 1 Closer w/ Hold-Open UNI-7500 H 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Smoke Seal PK 55 BL 17' PE 1 Raindrip 346 C 40" PE 1 Door Bottom 345 AV 36" PE 1 Threshold 2727 A 36" WSLS10 PE

Page 5: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 4 of 7

SET #8.0 - Exterior Cage & Storage Room Pair

• Doors: 132A 6 Hinges T4A3386 4 1/2 X 4 1/2 NRP 32D MC 1 Set Flush Bolts 2845 US32D RO 1 Lockset ML2059 PSA x L4 x MK x SA114 630 CR 1 Coordinator 2672 BLK RO 2 Closer w/ Hold-Open UNI-7500 H 689 NO 2 Protection Plate K1050 10" x 35" US32D RO 1 Dust Proof Strike 570 US26D RO 2 Mounting Bracket 2601C BLK RO 1 Smoke Seal PK 55 BL 20' PE 1 Astragal Seal S44 BL 17' PE 1 Raindrip 346 C 76" PE 2 Door Bottom 345 AV 36" PE 1 Threshold 2727 A 72" WSLS10 PE

- NOTE: Overlapping Astragal by Hollow Metal Door Manufacturer. SET #9.0 - Exterior Rollup Door By Others

• Doors: 153B

- NOTE: All hardware will be provided by the door manufacturer. SET #10.0 - Interior Stairwell Door with Exit Device

• Doors: S2 3 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Fire Exit Device ED5200A x PR910 M110 630 CR 1 Closer PR7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #11.0 - Single Entry Doors with Access Control

• Doors: 102A, 114B, 151B, 155B, 201, 259A, 259B 3 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Lockset CL3357 PZD L4 MK 626 CR 1 Electric Strike 1600-CLB 630 HS 1 Closer 7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO 1 Controller 2005M3 HS 1 Smoke Seal PK 55 BL 17' PE

- NOTE: Card Reader, Door Position Indicator, and Request to Exit Switch are to be furnished by Owner/Security Contractor. Wiring and coordination by others.

Page 6: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 5 of 7

SET #12.0 - AD Systems Sliding Doors

• Doors: 104A, 104B, 117, 118, 119, 120, 121, 125, 126, 128, 129, 131, 133B, 135, 137, 138, 139, 140, 143, 144, 145, 146, 149, 157, 209, 210, 211, 212, 213, 218, 219, 220, 221, 228, 229, 230, 231, 232, 235, 236, 238, 239, 240

1 Door Pull RM3300 24" OA. CTC US32D RO 1 Door Pull RM3300 24" OA. CTC TYPE 5HD FASTENING US32D RO

- NOTE: All Sliding Door Hardware including (but limited to) hangers, floor guide, aluminum track and surround to be provided by AD Systems. Wood Door and Pull Handles shown above to be provided by door supplier.

SET #13.0 - 2nd Floor Exits from Conference Area

• Doors: 247A, 248A 3 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Exit Device ED5200 x PR955 6P L4 M110 630 CR 1 Closer PR7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO SET #14.0 - Wrapped Drywall Opening (NO D/F/H)

• Doors: 103C, 103D, 247B, 249B, 252C, 252D

- NOTE: Openings are Cased Drywall. No Door, Frame, or Hardware for these openings. SET #15.0 - DBL Egress Hallway Entry/Exit Pairs

• Doors: 114A, 134A, 208, 224 4 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 2 Electric Hinge T4A3786 4 1/2 x 4 1/2 QC12 26D MC 2 Fire Exit Device ED5860B M110 M92 MELR 630 CR 1 Magnalock M62B US32D SN 1 PowerMatic Operator -Push Side 6070 689 NO 1 PowerMatic Operator -Pull Side 6050 689 NO 2 Protection Plate K1050 10" x 35" US32D RO 2 Wall Bumper 409 US32D RO 2 Door Switch 505 NO 1 Power Supply AQD2 SN 2 ElectroLynx Harness QC-C012P MC 2 Weatherstrip 18041 CNB 84" PE 1 Smoke Seal PK 55 BL 20' PE

- NOTE: Card Reader and Door Position Indicator are to be furnished by Owner/Security Contractor. Request to Exit (REX) in the form of Touchbar Monitoring is included in the Exit Device's Touch Pad. Wiring and coordination by others. M62B to be mounted on hallway side in order to lock the RH door if traveling from the Lobby to the treatment area. Magnet to release in case of fire alarm (Fail Safe)

Page 7: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 6 of 7

SET #16.0 - Doctor's Offices, Admin Offices, & Conf

• Doors: 103A, 103B, 110, 111, 112, 113, 115, 123, 127, 133A, 141, 147, 158, 203, 204, 205, 206, 214, 215, 216, 233, 234, 237, 249A, 252A, 252B

3 Hinges T4A3786 4 1/2 X 4 1/2 26D MC 1 Lockset CL3351 PZD L4 MK 626 CR 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #17.0 - Storage Rooms

• Doors: 102B, 106, 130, 132B, 161, 217, 242, 250 3 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Lockset CL3357 PZD L4 MK 626 CR 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #18.0 - Mortise Locks with Indicators

• Doors: 108, 109, 122, 142, 162, 202, 207, 222, 226, 251 3 Hinges T4A3786 4 1/2 X 4 1/2 26D MC 1 Privacy Set ML2030 PSA M19VN SA114 626 CR 1 Emergency Key 398F438 N/A CRPT 1 Closer 7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #19.0 - Multi-Occupant RR with Push/Pulls

• Doors: 163, 165, 243, 245 3 Hinges T4A3786 4 1/2 X 4 1/2 26D MC 1 Door Pull 110 X 70C US32D RO 1 Push Plate 70C-RKW 4 X 16 US32D RO 1 Closer 7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE

Page 8: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

201556 : Evergreen Family & Women's Health

REVISION #1 - March 11, 2019 1:40 pm Page - 7 of 7

SET #20.0 - Passage Sets

• Doors: 241 3 Hinges T4A3786 4 1/2 X 4 1/2 26D MC 1 Passage Set CL3310 PZD 626 CR 1 Wall Bumper 409 US32D RO 1 Smoke Seal PK 55 BL 17' PE SET #21.0 - Panic Devices with Access Control

• Doors: 148B, 155A, 265A 2 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Electric Hinge T4A3786 4 1/2 x 4 1/2 QC12 26D MC 1 Fire Exit Device ED5200A x PR959 6P L4 M110 M92 MELR 630 CR 1 Closer PR7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Wall Bumper 409 US32D RO 1 Power Supply AQD2 SN 1 ElectroLynx Harness QC-C012P MC 1 Smoke Seal PK 55 BL 17' PE SET #22.0 - Fire Rated Exit Pair with DBL Operator

• Doors: 114C 4 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 2 Electric Hinge T4A3786 4 1/2 x 4 1/2 QC12 26D MC 1 Elect. Exit Device w/Trim ED5470B x PR955 M110 M55 M92 MELR 630 CR 1 Exit Device w/Trim ED5470B x PR955 M110 M55 M92 630 CR 2 PowerMatic Operator 6060 689 NO 2 Protection Plate K1050 10" x 35" US32D RO 2 Wall Bumper 409 US32D RO 2 Door Switch 505 NO 1 Power Supply AQD2 SN 2 ElectroLynx Harness QC-C012P MC 2 Weatherstrip 18041 CNB 84" PE 1 Smoke Seal PK 55 BL 20' PE SET #23.0 - Fire Rated Closet Door Bio Waste

• Doors: 150 3 Hinges T4A3786 4 1/2 X 4 1/2 NRP 26D MC 1 Lockset CL3357 PZD L4 MK 626 CR 1 Closer w/Stop Arm CLP-7500 689 NO 1 Protection Plate K1050 10" x 34" US32D RO 1 Smoke Seal PK 55 BL 17' PE

Page 9: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-03

SITE FURNINSHING – BIKE RACKS 32-33-03-1

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-03-1

PART 1 GENERAL

1.1 CONTRACT CONDITIONS

A. Work of this Section is bound by the Contract Conditions and Division 1, bound

herewith, in addition to the Specification and accompanying Drawings

1.2 SUBMITTALS

A. Submit under provisions of Section 01 30 00 - Administrative Requirements.

B. Product Data: Manufacturer's data sheets on each product to be used, including full

range of standard color selections.

C. Shop Drawings: Indicate materials, dimensions, tolerances, welding, fasteners,

hardware, mounting, finish, and accessories.

D. Quality Assurance Submittals:

1. Qualifications: Proof of manufacturer qualifications.

2. Manufacturer's Installation Instructions.

E. Selection Samples: Color charts illustrating full range of colors and patterns.

1.3 QUALITY ASSURANCE

A. Manufacturer Qualifications: Minimum five years experience in producing bicycle

racks of the types specified.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer’s unopened packaging until ready to install.

B. Handle parts with sufficient care to prevent scratches and other damage to the finish.

C. Materials delivered to the site shall be examined for concealed damage or defects in

shipping. Defects shall be noted and reported to the Owner's Representative in

writing.

1.5 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within

limits recommended by manufacturer for optimum results. Do not install products

under environmental conditions outside manufacturer's absolute limits.

1.6 WARRANTY

A. Warranty: Manufacturer's standard warranty.

1. Seller warranties to replace, or at seller's option, repair any product or part

thereof which is found to be defective in material or workmanship for a period

Page 10: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-03

SITE FURNINSHING – BIKE RACKS 32-33-03-2

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-03-2

of two years from date buyer accepts products. All parts and labor required

under warranty provisions shall be supplied free of charge.

2. Transportation costs of returning the products to and from repair facility or

costs involved with contractor personnel traveling to buyer's facility for the

purpose of repairing products on site shall be borne by seller during 2 year

warranty period.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Huntco Site Furnishings, which is located at: P. O. Box

10385; Portland, OR 97296; Toll Free Tel: 800-547-5909; Tel: 503-224-8700; Fax:

503-274-2055; Email: request info ([email protected]); Web: www.huntco.com

B. Requests for substitutions will be considered in accordance with provisions of

Section 01 60 00 - Product Requirements.

2.2 BICYCLE RACKS

1. Model: Rambler Wide

2. Materials

a. Mild Steel, Schedule 40 steel pipe; 2-3/8 inch OD x .154 inch wall

3. Finishes

a. Hot dipped galvanized.

b. Polyester powder coating (TGIC), 3-4 mils.

1) Colors: Black

4. Capacity

a. Bicycle Capacity: 2

5. Mounting

b. Mounting: Surface flanged for bolting to concrete.

PART 3 EXECUTION

1.1 EXAMINATION

A. Examine substrates upon which bicycle racks will be installed. Verify that surfaces

are clean, flat and level within manufacturer's recommended installation tolerances.

B. If preparation is the responsibility of another installer, notify Architect of deviations

from manufacturer's recommended installation tolerances and conditions.

C. Do not proceed with installation until substrates have been properly prepared and

deviations are corrected.

Page 11: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-03

SITE FURNINSHING – BIKE RACKS 32-33-03-3

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-03-3

D. Commencement of installation constitutes acceptance of conditions.

1.2 INSTALLATION

A. Install bicycle racks in accordance with manufacturer's installation instructions.

B. Install bicycle racks level, plumb, square, accurately aligned, correctly located per

drawings, and without warp.

C. Mounting: Hardware and fasteners in accordance with manufacturer's instructions

1. For Surface Flange Mounted Bicycle Racks: Anchor bicycle racks

securely in place with 1/2 inch x 4 inch anchor bolts through flange holes.

1.3 CLEANING AND PROTECTION

A. Clean in accordance with manufacturer's recommendations.

B. Protect installed products until completion of project.

C. Touch-up, repair or replace damaged products and finishes in accordance with

manufacturer's instructions before Substantial Completion.

END OF SECTION

Page 12: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-02

SITE FURNISHINGS-TRASH AND LITTER RECEPTACLES 32-33-02-1

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 32-33-01-1

PART 1 GENERAL

1.1 CONTRACT CONDITIONS

A. Work of this Section is bound by the Contract Conditions and Division 1, bound herewith, in

addition to the Specification and accompanying Drawings

1.2 REFERENCES

A. ASTM Testing Standards:

1. ASTM B 117 – Standard Practice for Operating Salt Spray (Fog) Apparatus.

2. ASTM D 522 – Standard Test Methods for Mandrel Bend Test of Attached Organic

Coatings.

3. ASTM D 523 – Standard Test Method for Specular Gloss.

4. ASTM D 2247 – Standard Practice for Testing Water Resistance of Coatings in 100%

Relative Humidity.

5. ASTM D 2794 – Standard Test Method for Resistance of Organic Coatings to the Effects of

Rapid Deformation (Impact).

6. ASTM D 3359 – Standard Test Methods for Measuring Adhesion by Tape Test.

7. ASTM D 3363 – Standard Test Method for Film Hardness by Pencil Test.

8. ASTM G 155 – Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of

Non-Metallic Materials.

B. ISO Testing Standards:

1. ISO 1520 – Paints and Varnishes – Cupping Test.

2. ISO 2815 – Paints and Varnishes – Buchholz Indentation Test.

1.2 SUBMITTALS

A. Product Data: Submit manufacturer’s product data, storage and handling requirements and

recommendations, installation methods and available colors, styles, patterns and textures.

B. Shop Drawings: Submit manufacturer’s shop drawings, including plans and elevations, indicating

overall dimensions.

C. Samples: Submit manufacturer’s samples of materials, finishes, and colors.

D. Warranty: Manufacturer’s standard warranty.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Manufacturer regularly engaged in manufacture of site furnishings

since 1969.

B. Product Support: Products are supported with complete engineering drawings and design patents.

C. Base Worth: An installed base of products worth in excess of one hundred million dollars.

D. Assets: Excess of twenty million dollars in assets.

E. Production: Orders are filled within a 40-day schedule.

F. Facility Operator: Welders and machine operators are certified.

Page 13: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-02

SITE FURNISHINGS-TRASH AND LITTER RECEPTACLES 32-33-02-2

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 32-33-01-2

1.4 DELIVERY, STORAGE, AND HANDLING

A. Delivery: Deliver materials to site in manufacturer’s original, unopened containers and packaging,

with labels clearly identifying product name and manufacturer.

B. Storage: Store materials in clean, dry area in accordance with manufacturer’s instructions. Keep

materials in manufacturer’s original, unopened containers and packaging until installation.

C. Handling: Protect materials and finish during handling and installation to prevent damage.

1.5 WARRANTY

A. Warranty Information:

-Products will be free from defects in material and/or workmanship for a period of three years

from the date of invoice.

-The warranty does not apply to damage resulting from accident, alteration, misuse, tampering,

negligence, or abuse.

- Landscape Forms, Inc. shall, at its option, repair, replace, or refund the purchase price of any

items found defective upon inspection by an authorized Landscape Forms service representative.

-Purchasers should be aware that normal use of these high quality products can result in

superficial damage affecting the finish. Scratches, nicks, and dents are to be considered normal

wear and tear, and are not the responsibility of the manufacturer.

PART 2 PRODUCTS

2.1 MANUFACTURER

A. Landscape Forms, Inc., 7800 E. Michigan Ave, Kalamazoo, Michigan 49048. Phone:

(800) 521-2546. Fax (269) 381-3455. Website www.landscapeforms.com E-mail:

[email protected]

2.2 TRASH AND LITTER RECEPTORS

A. “FGP” Litter Receptacle

B. Style:

1. Side opening unit

C. Mounting:

1. Freestanding/surface mount: Non-corrosive anchoring hardware not included.

2.4 MATERIAL

A. Lid and top ring: A356 or A360 cast aluminum

B. Side panel:

1. Wood for Exterior Use:

A. Domestically sourced thermally modified ash.

C. Liner: Rotationally molded linear low density polyethylene. Color is black.

Page 14: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-02

SITE FURNISHINGS-TRASH AND LITTER RECEPTACLES 32-33-02-3

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 32-33-01-3

D. Base: Rotationally molded linear low density polyethylene. Color is black. Base is filled with

concrete for stability.

E. Hardware: Wood slats are attached to base and top ring with carbon steel with Magni-coated

hardware.

F. Hinge: 5mm D-profile shaft with M4 hex head set screw, both are carbon steel with Magni-coat.

G. Lid bumpers: Nylon 6/6. Color is gray.

2.5 RECYCLED CONTENT

Post-Consumer

Content Pre-Consumer Content

Side opening litter, jarrah 0% 50%

Unit is 100% recyclable.

2.6 FABRICATION

A. Shop assembled litter receptacles.

2.7 FINISHES

A. Finish on metal: Landscape Forms, Inc. “Pangard II”.

1. Primer: Rust inhibitor.

2. Topcoat: Thermosetting polyester powdercoat. UV, chip, and flake resistant.

3. Test Results: “Pangard II”.

a. Gloss, Garner 60 Degrees, ASTM D 523: Plus or minus 5.

b. UV Resistance, Color and Gloss, ASTM G 155, Cycle 7: Delta E less than 2 at 2.0

mils and less than 20 percent loss.

c. Cross-Hatch Adhesion, ASTM D 3359, Method B: 100 percent pass.

d. Flexibility Test, Mandrel, ASTM D 522: 3 mm at 2 mils.

e. Erichsen Cupping, ISO 1520: 8 mm.

f. Impression Hardness, Buchholz, ISO 2815: 95.

g. Impact Test, ASTM D 2794: 60 inches/pound at 2.5 mils.

h. Pencil Hardness, ASTM D 3363: 2H minimum.

i. Corrosion Resistance, 1,500-Hour Test, ASTM B 117: Max undercutting 1 mm.

j. Humidity Resistance, 1,500-Hour Test, ASTM D 2247: Max blisters 1 mm.

4. Color: Matt Black

B. Finish on Wood:

1. Wood for Exterior Use: Unfinished.

PART 3 EXECUTION

Page 15: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-02

SITE FURNISHINGS-TRASH AND LITTER RECEPTACLES 32-33-02-4

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 32-33-01-4

3.1 EXAMINATION

A. Examine areas to receive litter receptacles.

B. Notify Architect of conditions that would adversely affect installation or subsequent use.

C. Do not begin installation until unacceptable conditions are corrected.

3.2 INSTALLATION

A. Install litter receptacles in accordance with manufacturer’s instructions at locations indicated on

the Drawings.

B. Install litter receptacles level and plumb.

C. Anchor litter receptacles securely in place, if required.

3.3 ADJUSTING

A. Finish Damage: Repair minor damages to finish in accordance with manufacturer’s instructions

and as approved by Architect.

B. Component Damage: Remove and replace damaged components that cannot be successfully

repaired as determined by Architect.

3.4 CLEANING

A. Clean litter receptacles promptly after installation in accordance with manufacturer’s instructions.

B. Do not use harsh cleaning materials or methods that could damage finish.

3.5 PROTECTION

A. Protect installed litter receptacles to ensure that, except for normal weathering, receptacles will be

without damage or deterioration at time of Substantial Completion.

END OF SECTION

Page 16: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-01

SITE FURNISHINGS-BENCHES 32-33-01-1

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-01-1

PART 1 GENERAL

1.1 CONTRACT CONDITIONS

A. Work of this Section is bound by the Contract Conditions and Division 1, bound herewith, in

addition to the Specification and accompanying Drawings

1.2 REFERENCES

A. ASTM Testing Standards:

1. ASTM B 117 – Standard Practice for Operating Salt Spray (Fog) Apparatus.

2. ASTM D 522 – Standard Test Methods for Mandrel Bend Test of Attached Organic

Coatings.

3. ASTM D 523 – Standard Test Method for Specular Gloss.

4. ASTM D 2247 – Standard Practice for Testing Water Resistance of Coatings in 100%

Relative Humidity.

5. ASTM D 2794 – Standard Test Method for Resistance of Organic Coatings to the Effects of

Rapid Deformation (Impact).

6. ASTM D 3359 – Standard Test Methods for Measuring Adhesion by Tape Test.

7. ASTM D 3363 – Standard Test Method for Film Hardness by Pencil Test.

8. ASTM G 155 – Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of

Non-Metallic Materials.

B. ISO Testing Standards:

1. ISO 1520 – Paints and Varnishes – Cupping Test.

2. ISO 2815 – Paints and Varnishes – Buchholz Indentation Test.

1.3 SUBMITTALS

A. Product Data: Submit manufacturer’s product data, storage and handling requirements and

recommendations, installation methods and available colors, styles, patterns and textures.

B. Shop Drawings: Submit manufacturer’s shop drawings, including plans and elevations, indicating

overall dimensions.

C. Samples: Submit manufacturer’s samples of materials, finishes, and colors.

D. Warranty: Manufacturer’s standard warranty.

1.4 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Manufacturer regularly engaged in manufacture of site furnishings

since 1969.

B. Product Support: Products are supported with complete engineering drawings and design patents.

C. Base Worth: An installed base of products worth in excess of one hundred million dollars.

D. Assets: Excess of twenty million dollars in assets.

E. Production: Orders are filled within a 40-day schedule.

F. Facility Operator: Welders and machine operators are certified.

1.5 DELIVERY, STORAGE, AND HANDLING

Page 17: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-01

SITE FURNISHINGS-BENCHES 32-33-01-2

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-01-2

A. Delivery: Deliver materials to site in manufacturer’s original, unopened containers and packaging,

with labels clearly identifying product name and manufacturer.

B. Storage: Store materials in clean, dry area in accordance with manufacturer’s instructions. Keep

materials in manufacturer’s original, unopened containers and packaging until installation.

C. Handling: Protect materials and finish during handling and installation to prevent damage.

1.6 WARRANTY

A. Warranty Information:

-Products will be free from defects in material and/or workmanship for a period of three years

from the date of invoice.

-The warranty does not apply to damage resulting from accident, alteration, misuse, tampering,

negligence, or abuse.

- Landscape Forms, Inc. shall, at its option, repair, replace, or refund the purchase price of any

items found defective upon inspection by an authorized Landscape Forms service representative.

-Purchasers should be aware that normal use of these high quality products can result in

superficial damage affecting the finish. Scratches, nicks, and dents are to be considered normal

wear and tear, and are not the responsibility of the manufacturer.

PART 2 PRODUCTS

2.1 MANUFACTURER

A. Landscape Forms, Inc., 7800 E. Michigan Ave, Kalamazoo, Michigan 49048. Phone:

(800) 521-2546. Fax (269) 381-3455. Website www.landscapeforms.com E-mail:

[email protected]

2.2 Benches

A. Strata Beam Bench:

1. Bench style

a. Backed straight, 80in length

2. Arm options: no arms available on 31in or 69in length benches

a. No arms

3. Mounting options:

a. Surface mount

2.3 MATERIALS

A. Seat and back panels:

1. Wood for Exterior Use:

a. Domestically sourced thermally modified ash.

Page 18: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-01

SITE FURNISHINGS-BENCHES 32-33-01-3

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-01-3

B. End frames: Ultra high performance concrete, proprietary blend. UV stable pigments are

incorporated into the concrete mixture. Attached to seat with Magni-coated steel hardware. Mix

proportions:

Material: %

Meldstone™ premix: 53.8%

Cement: 33.7%

Water: 11.8%

SP liquid: 0.5%

PVA fibers: 0.2%

Compressive strength after cure: minimum 18,000 psi (125 MPa)

Flexural strength after cure: minimum 2100 psi (14.5 MPa)

C. Backed bench straps: aluminum castings

D. Glides: Stainless steel, adjustable

E. Surface mount tabs: (2) 1/4” thick 304 stainless steel tabs per bench. Anchoring hardware not

included.

F. Embedded hardware: (4) stainless steel 3/8-16 threaded rods, included

2.4 RECYCLED CONTENT minimums shown. All units are 100% recyclable.

Post-Consumer

Content

Pre-Consumer

Content

bench, 31in, backless, no

arms 2% 4%

bench, 69in, backless, no

arms 3% 4%

bench, 80in, backless, no

arms 3% 4%

bench, 80in, backless, 2 arms 5% 5%

bench, 80in, backless, 4 arms 7% 6%

bench, backed, no arms 0% 2%

bench, backed, 2 arms 2% 3%

bench, backed, 4 arms 4% 4%

2.5 FINISHES

A. Finish on metal: Landscape Forms, Inc. “Pangard II”.

1. Primer: Rust inhibitor.

2. Topcoat: Thermosetting polyester powdercoat. UV, chip, and flake resistant.

3. Test Results: “Pangard II”.

a. Gloss, Garner 60 Degrees, ASTM D 523: Plus or minus 5.

b. UV Resistance, Color and Gloss, ASTM G 155, Cycle 7: Delta E less than 2 at 2.0

mils and less than 20 percent loss.

c. Cross-Hatch Adhesion, ASTM D 3359, Method B: 100 percent pass.

d. Flexibility Test, Mandrel, ASTM D 522: 3 mm at 2 mils.

e. Erichsen Cupping, ISO 1520: 8 mm.

f. Impression Hardness, Buchholz, ISO 2815: 95.

Page 19: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-01

SITE FURNISHINGS-BENCHES 32-33-01-4

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-01-4

g. Impact Test, ASTM D 2794: 60 inches/pound at 2.5 mils.

h. Pencil Hardness, ASTM D 3363: 2H minimum.

i. Corrosion Resistance, 1,500-Hour Test, ASTM B 117: Max undercutting 1 mm.

j. Humidity Resistance, 1,500-Hour Test, ASTM D 2247: Max blisters 1 mm.

4. Surface mount tabs (if specified): stainless steel, no finish

B. Concrete:

1. Color of bench supports, as cast finish: Natural Black

C. Finish on Wood:

1. Wood for Exterior Use: Unfinished.

PART 3 EXECUTION

3.1 EXAMINATION

A. Examine areas to receive benches.

B. Notify Architect of conditions that would adversely affect installation or subsequent use.

C. Do not begin installation until unacceptable conditions are corrected.

3.2 INSTALLATION

A. Install benches in accordance with manufacturer’s instructions at locations indicated on the

Drawings.

B. Install benches plumb and level.

3.3 ADJUSTING

A. Finish Damage: Repair minor damages to finish in accordance with manufacturer’s instructions

and as approved by Architect.

B. Component Damage: Remove and replace damaged components that cannot be successfully

repaired as determined by Architect.

3.4 CLEANING

A. Clean benches promptly after installation in accordance with manufacturer’s instructions.

B. Do not use harsh cleaning materials or methods that could damage finish.

3.5 PROTECTION

A. Protect installed benches to ensure that, except for normal weathering, benches will be without

damage or deterioration at time of Substantial Completion.

Page 20: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 32-33-01

SITE FURNISHINGS-BENCHES 32-33-01-5

EVERGREEN FAMILY & WOMENS HEALTH CLINIC REMODEL 32-33-01-5

END OF SECTION

Page 21: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

UP

UP

UP

DW

UP

A2012

A201

A201

A201

1

4

3

1

1

2

2

4

4

5

5

6

6

7

7

A A

B B

C C

D D

E E

(E) STAIR

AMBULANCE

ENTRANCE

3

A302

3

A302

SHWR

SHWR

2

A302

2

A302

4

A302

4

A302

5

A302

5

A302

3

A3013

A301

2

A301

2

A301

1

A301

1

A301

4

A301

4

A301

3

1A

2

6

3

3

3

2

3

3

3

3

99

9

4

44

4

4

4446

6

2

4 4

4 4 4

4

4

9

4

1A

5 3 5 5 5 5 5 5 5

5 5

4

5

5

4

54

5

5

9

5 5 5 5

6

6

5

3

4

4

4

7

6

6

6

6

6

6

6

6

1

A302

1

A302

4

ELEVATOR

D1042

D104

1

D104

3

D104 4

A401 7

A403

1

2

ADMIN

111

ADMIN

110

ADMIN

112

IT

113

STOR & MECH

106

BEHAVIORAL

HEALTH

115

TREATMENT

117

TREATMENT

119

CHECKOUT

116

CHECKOUT

136

ADMIN

104

PROCEDURE

121

DR. OFFICE

123

TREATMENT

125

DR. OFFICE

127

TREATMENT

129

TREATMENT

131

CAGE AND

STORAGE

132

LAUNDRY

130

TREATMENT

128

TREATMENT

146

TREATMENT

126

TREATMENT

144

IT RACK &

ELECTRICAL

151

RECEIVING

153

FS RISER

154

TRASH

152

TREATMENT

149

DR OFFICE

147

TREATMENT

145

PROCEDURE

143

DR OFFICE

141

TREATMENT

139

TREATMENT

137

TREATMENT

135

VACCINE

133

BREAK ROOM

159

LACTATION

162

TREATMENT

138

TREATMENT

140

R.R.

122TREATMENT

120

TREATMENT

118

BILLING MGR

OFFICE

158

MN'S LCKRS

165

MN'S R.R.

166

STRG.

161

WMN'S R.R.

164

WMN'S LCKRS

163

BILLING

156

CALL CENTER

157

NURSE STATION

124

NORTH HALLWAY

114

SOUTH HALLWAY

134

3

3

9

1B

1A

1B

1A

1B 1A 1A 1A

1A

1A

1B

1A

1A

1B

1A

1A

1A

1B

1D1D

1D

1D

1D

1D 1D

1D1D

1D

1D

1A

1D

1D

1D

1A

1D

1B

1A

1B

1A1A1B

1A1B1A1B

6

6

6

6

6

6

R.R.

108

R.R.

109

WASTE

150

A403

3

4STRG

250

101A 101B

102A

102B

110111

112 113

108

250

109

133A 133B 135 137 139 141 143 145 147 149

152

154

153A

151B

LOUNGE

155

WAITING AREA

107

144 146

134A

138 140

142

126 128

130

132A

132B

131129127125123121119117115

114B

162

161163

165

155A

155B

156

158

M1 S1

157

103A

103B

148A

LOBBY

148

114C

150

106

122120118

104B

104A

153B

10' - 0

"2' - 0

"

8

RECEPTION

103

LOBBY

102

A401

11

A504

8TYP

5' - 0" 5' - 0"

10

A402

1

A402

8

A404

1

A405

1

A405

6TYP

A405

11TYP

A405

13TYP

A405

15

A406

6

A405

8

A406

1

A406

9

A407

1

5' - 11"

18' - 4 3/4"

16' - 5"

2' - 2

3/4

"

4

4

6' - 0"

1' - 10

"

6' - 6

1/2"

5' - 2

"

5' - 3" 5' - 10 1/2" 2' - 1 1/2"

R.R.

142

2' - 2"

2' - 0

"

2' - 7 1/2"13' - 2 1/4"

2' - 1"

2' - 8"

10' - 3

1/2"

6' - 6

" 114A 24' - 0 1/4" 12' - 7 1/2"

5' - 0"

17' - 6 1/2"

ALIGN W/ (E)

EXTERIOR

WALL

A401

14

A401

6

9

ALIGN

6

4' - 3" 4' - 2 1/2" 5' - 2 1/2" 3' - 0" 4' - 3" 3' - 0" 4' - 0 1/2" 4' - 3"

3' - 2

"

ALIGN

3' - 0 1/4"

10' - 6 3/4"

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

8' - 9 3/4" 10' - 2" 10' - 1"

4' - 2 1/2" 4' - 3"

5' - 9"

7' - 0 1/2"9' - 8 1/2" 10' - 4 1/4" 10' - 2 1/2"

ALIG

N

4' - 2 1/2" 4' - 3"

3' - 0

"

4' - 2 1/2"4' - 3"

7' - 8

3/4

"7' - 8

3/4

"

4

7

7

3' - 0"

3' - 0"4' - 3"4' - 2 1/2"

4' - 2 1/2"

3' - 0

"

3' - 0"4' - 2 1/2"5' - 2 1/2"3' - 0"4' - 0 1/2"4' - 2 1/2"4' - 3"4' - 11"2' - 0 1/2"

9' - 4 1/4" 8' - 4 1/4" 12' - 7 3/4" 12' - 4 1/2" 12' - 4 1/2" 13' - 4" 18' - 4 3/4" 12' - 2" 12' - 0 1/2"

6' - 6

1/2"

ALIGN

2' - 10"

9' - 2

1/2"

4' - 1 3

/4

"8

' - 0

"4

' - 1 3

/4

"

9' - 2

1/2"

2' - 4 1/4" 3' - 0"

3' - 0"2' - 4 1/4"

14' - 10

1/4

"

ALIG

N

5' - 1 1/4

"

1' - 10

3/4

"

2' - 8

1/2"

2' - 0"

2' - 0"

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

3' - 11 1/4" 5' - 11 1/2"

2' - 2

"

4

4

8' - 4

"4

' - 1 1/2"

5' - 0

1/2"

8' - 1 1/4

"

6' - 10 3/4"

5' - 11 1/

2"

3' - 0

"

7' - 9"

10' - 3

1/2"

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS ALIGN

ALIGN

W/EDGE OF

SOFFIT

ABOVE

CENTER WALL

BETWEEN (E)

WINDOW

OPENINGS

5

3

A401 4

KITCHENETTE

160

103C

103D

A405

20

2221

2

(E) ROOF DRAIN

EXTEND (E) WALL

FOR HANDRAIL RETURN

4"

1' - 0

"

3' - 0

"

12

3

3

36" HT WALLS

6

6

155C

A4012

1

A401 13

2'-0"VERIFY THAT DOOR SWING

WILL NOT INTERFERE

W/EXISTING METER BASE

163A

165A

10

10

1E

FEC

FEC

FE

FEC

FEC

FE

FEC

33

3

3

3

4

4

4

3

ALIG

N

3

3A

4

2

3

2

2

2

4

10

33A

A609

2

8'-

8"

4'-

0"

5 3

/4

"

1 3/4" 22' - 11"

5

A611

1

A402

8

SIM

5' - 0" 5' - 0"

A401 7

Sim

6" 6'-1 1/4"

7' - 0 3/4" 5' - 6 1/4" 7' - 5"

10' - 2

1/4

"

1 1 1 1 1 1 1 1 1 1 1 1 1 1

111111111

1

1

11

1

1

1

1

11

1

1

1

1

1

1

1

1

1

1 1 1 1

2

2

6 6 6 6

6666

ALIGN W/

STRUCTURE

ALIGN W/ OUTSIDE

OF SHEATHING

CLCL

ALIG

N W

/

STR

UC

TUR

E

A501

3

A501

2

MIN.

1' - 6"

SEE INT. ELEVATIONS FOR

WALL OPENING LOCATION

17' - 7 1/2"

1'-0"

6

A611

TYP. FOR

HALF WALLS

4" CONC. PAD W/

#4 REBAR @2' O.C.

EA. WAY

5' - 8 1/4"

CANOPY

(N) STEEL

DOOR & STEEL

DOOR FRAME

A303

1

1'-3

"

EQ 5'-5 3/4" EQ

12'-0" 5'-5 3/4" 12'-0"

148B

2'-

4"

7

7

7

7

7

7

7

7

CENTER SCREENS

BETWEEN (E) WINDOW

OPENINGS (TYP)

SS-1

1

SHEET NOTES

1. ALL EXISTING BUILDING STRUCTURE TO REMAIN U.N.O.

2. ALL DIMENSIONS FROM THE FACE OF FRAMING, UNLESS NOTED

OTHERWISE.

3. FOR ALL EQUIPMENT DESIGNATIONS REFER TO EQUIPMENT SCHEDULE

ON A120.

4. FILLED-IN WALL CAVITIES SHALL BE EXEMPT FROM THE

REQUIREMENTS BY THE OREGON ENERGY CODE, ACCORDING TO

SECTION 101.4.2, EXCEPTION 4.

KEY NOTES

1 (N) WINDOW AT EXISTING OPENING

2 REPLACE (E) GLAZING WITH INSULATED GLAZING UNITS

3 FIRE EXTINGUISHER CABINET: HANDLE OF FIRE EXTINGUISHER

MAX. 4'-0" A.F.F.

4SURFACE MOUNTED FIRE EXTINGUISHER: HANDLE OF FIRE

EXTINGUISHER MAX. 4'-0" A.F.F.

5 EXTERIOR FACE OF (E) BEAM ABOVE

6 INTERIOR RE-LITE, REFER TO INTERIOR ELEVATIONS FOR SIZE

AND LOCATION

7 4x4 HSS POSTS NW/"GREENSCREEN" INFILL

8 KNOX BOX 3200, RECESS MOUNT, BLACK

ROOM

150 SF

KEYNOTE REFERENCE

DETAIL REFERENCEX

A50X

X

A30XSECTION REFERENCE

A20XELEVATION REFERENCE

DOOR TAG

X

X WALL TAG

WINDOW TAG

ROOM TAG

X

A40X INTERIOR ELEVATION REFERENCEX

X

30

WOOD STUD WALL

EXISTING (E) WALL

WALL KEY

STEEL STUD WALL

DRAWING LEGEND

121 Lawrence St. Eugene OR 97401

www.2−form.com

p. 541.342.5777f. 541.342.6128

2FORM ARCHITECTURE EXPRESSLY

RESERVES ITS COMMON LAW

COPYRIGHT AND OTHER

PROPERTY RIGHTS IN THESE

PLANS. THESE PLANS ARE NOT TO

BE REPRODUCED, CHANGED, OR

COPIED IN ANY FORM OR MANNER

WHATSOEVER, NOR ARE THEY TO

BE ASSIGNED TO A THIRD PARTY

WITHOUT FIRST OBTAINING THE

WRITTEN PERMISSION AND

CONSENT OF 2FORM

ARCHITECTURE. IN THE EVENT OF

AN UNAUTHORIZED REUSE OF THESE

PLANS BY A THIRD PARTY, THE

THIRD PARTY SHALL HOLD 2FORM

ARCHITECTURE HARMLESS.

PROJECT TITLE

REVISIONS

SYM DATE REFERENCE

DRAWING BY:

REVIEWED BY:

PROJECT NO.

DATE:

DRAWING TITLE

DRAWING NUMBER

R. SHUGAR

121 Lawrence St.Eugene, OR 97401

p. 541.342.5777f. 541.342.6158

1 4/4/19 Bid Addendum 1

EV

ER

GR

EE

N F

AM

ILY

& W

OM

EN

'S H

EA

LT

H1937 W

ES

T H

AR

VA

RD

AV

E.

RO

SE

BU

RG

, O

R 9

7471

PERMIT SET

Author

18003

3/22/2019

FIRST FLOOR PLAN

A1011/8" = 1'-0"1 FIRST FLOOR PLAN

Page 22: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

1A 2X6 EXTERIOR WALL W/STEEL SIDING

5/8" GWB

VAPOR RETARDER

(E) 2X6" STUDS

(E) 1/2" CDX PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

STEEL SIDING, SEE ELEVATIONS FOR TYPE & FINISH

1B 2X6 EXTERIOR WALL W/FLUSH PLANK SIDING

5/8" GWB

VAPOR RETARDER

(E) 2X6" STUDS

(E) 1/2" CDX PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

1X3" P.T. FURRING @ 24" O.C., VERTICAL

1X3" P.T. FURRING @ 24" O.C., HORIZONTAL

3" WIDE EPDM RUBBER @ FURRING

TRESPA "PURA" FLUSH SIDING, VERTICAL,

1C 2X6 EXTERIOR PARAPET WALL W/STEEL SIDING ON BOTH SIDES

"QUADRO" STEEL SHINGLE PANEL SIDING

WEATHERSMART DRAINABLE WRB

(E) 1/2" CDX PLYWOOD SHEATHING

(E) 2X6" STUDS

(E) 1/2" CDX PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

STEEL SIDING, SEE ELEVATIONS FOR TYPE & FINISH

1c1D 2X10 EXTERIOR FIN WALL W/STEEL SIDING ON BOTH SIDES

"QUADRO" STEEL SHINGLE PANEL SIDING

WEATHERSMART DRAINABLE WRB

(E) 1/2" CDX PLYWOOD SHEATHING

(E) 2X10" STUDS

(E) 1/2" CDX PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

"QUADRO" STEEL SHINGLE PANEL SIDING

1E 2X6 EXTERIOR SHEAR WALL W/STEEL SIDING

5/8" GWB

VAPOR RETARDER

1/2" CDX PLYWOOD SHEATHING

(E) 2X6" STUDS

(E) 1/2" CDX PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

STEEL SHINGLE PANEL SIDING

* SEE ELEVATIONS FOR SIDING TYPE AND FINISH

3 2X6 INTERIOR SHEAR WALL UL U327, 1 HR RATED, STC 45

5/8" TYPE X GWB

1/2" RESILIENT CHANNEL

(E) OR NEW 2X6" STUDS

3 1/2" MIN. FIBERGLASS INSULATION

(E) OR NEW 1/2" CDX PLYWOOD SHEATHING

5/8" TYPE X GWB

5 3 5/8" STEEL STUD INTERIOR WALL, UL U419, STC 54

5/8" GWB

3 5/8" STEEL STUDS @ 24" O.C.

3" MINERAL WOOL BATTS

1/2" RESILIENT CHANNEL

5/8" GWB

6 3 5/8" STEEL STUD INTERIOR WALL

5/8" GWB

3 5/8" STEEL STUDS @ 24" O.C.

5/8" GWB

9 2X6 INTERIOR SHEAR WALL W/ PLY ON BOTH SIDES

5/8" GWB

1/2" PLYWOOD SHEATHING

2X6" STUDS

3" MINERAL WOOL BATTS

1/2" PLYWOOD SHEATHING

5/8" TYPE X GWB

4 3 5/8" STEEL STUD INTERIOR WALL, UL U423, STC 45

5/8" GWB

3 5/8" STEEL STUDS @ 24" O.C.

3" MINERAL WOOL BATTS

5/8" GWB

2X4 INTERIOR SHEAR WALL

5/8" GWB

2X4" STUDS

1/2" PLYWOOD SHEATHING

5/8" TYPE X GWB

8

7

2 2X6 WALL UL U344, 1 HR RATED

5/8" TYPE X GWB

(E) 2X6" STUDS

5/8" TYPE X GWB

2X6 WALL W/ EXPOSED PLYWOOD

5/8" GWB

(E) 2X6" STUDS

R-21 INSULATION

(E) 1/2" PLYWOOD SHEATHING

WEATHERSMART DRAINABLE WRB

5/8" EXTERIOR GRADE PLYWOOD FINISH

10

6" STEEL STUD INTERIOR WALL, UL U423, STC 45

5/8" GWB

6" STEEL STUDS @ 24" O.C.

3" MINERAL WOOL BATTS

5/8" GWB

1

1

1A1 ROOF ASSEMBLY

(E) PVC ROOF MEMBRANE

(E) UNDERLAYMENT

(E) 3" RIGID INSULATION

(E) 1/2" CDX PLYWOOD SHEATHING

(E) 18" TJI @ 24" O.C.

A2 ROOF ASSEMBLY

(E) PVC ROOF MEMBRANE

(E) UNDERLAYMENT

(E) 3" RIGID INSULATION

(E) 1/2" CDX PLYWOOD SHEATHING

(E) 18" TJI @ 12" O.C.

B1 SECOND FLOOR ASSEMBLY

FLOOR FINISH & UNDERLAYMENT PER FINISH SCHEDULE

(E) 3/4" CDX PLYWOOD SUBFLOOR

(E) 24" TJI @ 16" O.C.

B2 SECOND FLOOR ASSEMBLY

FLOOR FINISH & UNDERLAYMENT PER FINISH SCHEDULE

(E) 3/4" CDX PLYWOOD SUBFLOOR

(E) 11 7/8" TJI @ 16" O.C.

C GROUND FLOOR ASSEMBLY

FLOOR FINISH & UNDERLAYMENT PER FINISH SCHEDULE

CONCRETE SEALANT

(E) 4" REINFORCED CONCRETE SLAB

D ENTRY CANOPY ASSEMBLY

STEEL ROOFING

(2) LAYERS ROOFING UNDERLAYMENT

3/4" P.T. PLYWOOD

P.T. CEILING JOISTS

EPDM RUBBER

TRESPA "PURA" FLUSH PLANK SIDING

121 Lawrence St. Eugene OR 97401

www.2−form.com

p. 541.342.5777f. 541.342.6128

2FORM ARCHITECTURE EXPRESSLY

RESERVES ITS COMMON LAW

COPYRIGHT AND OTHER

PROPERTY RIGHTS IN THESE

PLANS. THESE PLANS ARE NOT TO

BE REPRODUCED, CHANGED, OR

COPIED IN ANY FORM OR MANNER

WHATSOEVER, NOR ARE THEY TO

BE ASSIGNED TO A THIRD PARTY

WITHOUT FIRST OBTAINING THE

WRITTEN PERMISSION AND

CONSENT OF 2FORM

ARCHITECTURE. IN THE EVENT OF

AN UNAUTHORIZED REUSE OF THESE

PLANS BY A THIRD PARTY, THE

THIRD PARTY SHALL HOLD 2FORM

ARCHITECTURE HARMLESS.

PROJECT TITLE

REVISIONS

SYM DATE REFERENCE

DRAWING BY:

REVIEWED BY:

PROJECT NO.

DATE:

DRAWING TITLE

DRAWING NUMBER

R. SHUGAR

121 Lawrence St.Eugene, OR 97401

p. 541.342.5777f. 541.342.6158

1 4/4/19 Bid Addendum 1

EV

ER

GR

EE

N F

AM

ILY

& W

OM

EN

'S H

EA

LT

H1937 W

ES

T H

AR

VA

RD

AV

E.

RO

SE

BU

RG

, O

R 9

7471

PERMIT SET

Author

18003

3/22/2019

ASSEMBLIES

A104

1" = 1'-0"2 WALL ASSEMBLIES1" = 1'-0"1 HORIZONTAL ASSEMBLIES

Page 23: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

A

INTERIOR DOORS

EXTERIOR DOORS

(ENTRY)

7' - 0

"

6' - 0"

B

7' - 0

"

6' - 0"

C

(ENTRY)

6' - 5"

8' - 0

"

D

(ENTRY)

7' - 6

1/4

"

3' - 2"

E

AS

SC

HED

ULED

3' - 0"

F

(OVERHEAD)

13' - 4 1/4"

8' - 0

"

7' - 0

"

AS SCHEDULED

G H I J N

(MEDICAL ROOMS)

1' - 8"

2" HM FRAME

3' - 0"3'-0"

7' - 0

"

3'-5 1/4" 2'-0"

2" HM FRAME

3'-0"

7'-

0"

7'-

0"

6'-

11 3

/4

"

L

7' - 0

"

6' - 0"

121 Lawrence St. Eugene OR 97401

www.2−form.com

p. 541.342.5777f. 541.342.6128

2FORM ARCHITECTURE EXPRESSLY

RESERVES ITS COMMON LAW

COPYRIGHT AND OTHER

PROPERTY RIGHTS IN THESE

PLANS. THESE PLANS ARE NOT TO

BE REPRODUCED, CHANGED, OR

COPIED IN ANY FORM OR MANNER

WHATSOEVER, NOR ARE THEY TO

BE ASSIGNED TO A THIRD PARTY

WITHOUT FIRST OBTAINING THE

WRITTEN PERMISSION AND

CONSENT OF 2FORM

ARCHITECTURE. IN THE EVENT OF

AN UNAUTHORIZED REUSE OF THESE

PLANS BY A THIRD PARTY, THE

THIRD PARTY SHALL HOLD 2FORM

ARCHITECTURE HARMLESS.

PROJECT TITLE

REVISIONS

SYM DATE REFERENCE

DRAWING BY:

REVIEWED BY:

PROJECT NO.

DATE:

DRAWING TITLE

DRAWING NUMBER

R. SHUGAR

121 Lawrence St.Eugene, OR 97401

p. 541.342.5777f. 541.342.6158

1 4/4/19 Bid Addendum 1

EV

ER

GR

EE

N F

AM

ILY

& W

OM

EN

'S H

EA

LT

H1937 W

ES

T H

AR

VA

RD

AV

E.

RO

SE

BU

RG

, O

R 9

7471

PERMIT SET

Author

18003

3/22/2019

WINDOW & DOOR

SCHEDULE

A105

DOOR SCHEDULE

MARK WIDTH HEIGHT

DOOR

ELEVATION

Door

Material

Frame

Material FUNCTION COMMENTS

163A 2' - 10" 7' - 0" G WD/RIFT OAK HM WMNS SHOWER

165 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

165A 2' - 10" 7' - 0" G WD/RIFT OAK HM MENS SHOWER

201 3' - 0" 7' - 0" G WD/RIFT OAK HM ADMIN.

202 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

203 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

204 3' - 0" 7' - 0" G WD/RIFT OAK HM ADMIN.

205 3' - 0" 7' - 0" G WD/RIFT OAK HM ADMIN.

206 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

207 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

208 6' - 0" 7' - 0" L WD/RIFT OAK HM HALLWAY

209 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

210 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

211 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

212 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

213 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

214 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

215 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

216 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

217 3' - 0" 7' - 0" G WD/PAINT HM STORAGE

218 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

219 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

220 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

221 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

222 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

224 6' - 0" 7' - 0" L WD/RIFT OAK HM HALLWAY

226 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

228 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

229 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

230 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

231 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

232 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

233 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

234 3' - 0" 7' - 0" G WD/PAINT HM OFFICE

235 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

236 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

237 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

238 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

239 3' - 5 1/4" 6' - 11 1/2" I MAPLE OFFICE AD SYSTEMS EXAM SLIDE

240 3' - 5 1/4" 6' - 11 1/2" I MAPLE OFFICE AD SYSTEMS EXAM SLIDE

242 2' - 10" 7' - 0" G WD/RIFT OAK HM CUSTODIAL

243 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

245 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

247A 3' - 0" 7' - 0" G WD/RIFT OAK HM CONFERENCE

247B 21' - 0" 9' - 0" WALL OPENING CONFERENCE WRAP DRYWALL

248A 3' - 0" 7' - 0" G WD/RIFT OAK HM CONFERENCE

248F 3' - 0" 7' - 0" WALL OPENING

249A 3' - 0" 7' - 0" G WD/RIFT OAK HM CONFERENCE

249B 21' - 0" 9' - 0" WALL OPENING CONFERENCE WRAP DRYWALL

250 2' - 8" 7' - 0" G WD/RIFT OAK HM STORAGE

251 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

252A 3' - 0" 7' - 0" G WD/RIFT OAK HM RECEPTION

252B 3' - 0" 7' - 0" G WD/RIFT OAK HM RECEPTION

252C 3' - 7" 7' - 0" WALL OPENING RECEPTION WRAP DRYWALL

252D 3' - 7" 7' - 0" WALL OPENING RECEPTION WRAP DRYWALL

259A 3' - 0" 7' - 0" G WD/PAINT HM HALLWAY

259B 3' - 0" 7' - 0" G WD/RIFT OAK HM HALLWAY

265A 3' - 0" 7' - 0" H WD/RIFT OAK HM STAIR FLUSH SQUARE LIGHT MOULDING

265B 3' - 0" 6' - 8" EMETAL

HM ROOFTOP EXIT (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

M1 3' - 0" 6' - 8" EMETAL

HM MECH. (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

S1 3' - 0" 7' - 0" EMETAL

HM STAIR (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

S2 3' - 0" 6' - 8" EMETAL

HM STAIR (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

DOOR SCHEDULE

MARK WIDTH HEIGHT

DOOR

ELEVATION

Door

Material

Frame

Material FUNCTION COMMENTS

101A 6' - 0" 7' - 0" A ALUMINUM ALUMINUM ENTRY STOREFRONT, BLACK ANODIZED

101B 6' - 0" 7' - 0" A ALUMINUM ALUMINUM ENTRY STOREFRONT, BLACK ANODIZED

102A 3' - 0" 7' - 0" G WD/RIFT OAK HM ADMIN.

102B 3' - 0" 7' - 0" G WD/RIFT OAK HM STORAGE

103A 3' - 0" 7' - 0" G WD/RIFT OAK HM RECEPTION

103B 3' - 0" 7' - 0" G WD/RIFT OAK HM RECEPTION

103C 4' - 1" 7' - 0" WALL OPENING RECEPTION WRAP DRYWALL

103D 4' - 1" 7' - 0" WALL OPENING RECEPTION WRAP DRYWALL

104A 3' - 5 1/4" 6' - 11 1/2" I MAPLE ADMIN. AD SYSTEMS EXAM SLIDE

104B 3' - 5 1/4" 6' - 11 1/2" I MAPLE ADMIN. AD SYSTEMS EXAM SLIDE

106 3' - 0" 7' - 0" G WD/PAINT HM MECH.

108 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

109 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

110 3' - 0" 7' - 0" N WD/RIFT OAK HM ADMIN.

111 3' - 0" 7' - 0" N WD/RIFT OAK HM ADMIN.

112 3' - 0" 7' - 0" N WD/RIFT OAK HM ADMIN.

113 3' - 0" 7' - 0" N WD/RIFT OAK HM ADMIN.

114A 6' - 0" 7' - 0" L WD/RIFT OAK HM HALLWAY

114B 3' - 0" 7' - 0" G WD/RIFT OAK HM BREAK RM

114C 6' - 0" 7' - 0" L WD/RIFT OAK HM HALLWAY

115 3' - 0" 7' - 0" G WD/RIFT OAK HM MEDICAL

117 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

118 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

119 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

120 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

121 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

122 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

123 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

125 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

126 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

127 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

128 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

129 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

130 3' - 0" 7' - 0" G WD/PAINT HM LAUNDRY

131 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

132A 6' - 0" 7' - 0" BWD/RIFT OAK

HM STORAGE FLUSH SQUARE LIGHT MOULDING, FINISH TO MATCH FINISH OF OVERHEAD

DOOR

132B 3' - 0" 7' - 0" G WD/PAINT HM STORAGE

133A 3' - 0" 7' - 0" G WD/RIFT OAK HM MEDICAL

133B 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

134A 6' - 0" 7' - 0" L WD/RIFT OAK HM HALLWAY

135 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

137 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

138 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

139 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

140 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

141 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

142 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

143 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

144 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

145 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

146 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

147 3' - 0" 7' - 0" G WD/RIFT OAK HM OFFICE

148A 6' - 0" 8' - 0" C ALUMINUM ALUMINUM ENTRY STOREFRONT

148B 3' - 0" 7' - 0" H WD/RIFT OAK HM BACK LOBBY FLUSH SQUARE LIGHT MOULDING

149 3' - 5 1/4" 6' - 11 1/2" I MAPLE MEDICAL AD SYSTEMS EXAM SLIDE

150 3' - 0" 7' - 0" G WD/PAINT HM STORAGE

151B 3' - 0" 7' - 0" G WD/PAINT HM ADMIN.

152 3' - 0" 7' - 0" G WD/RIFT OAK HM ADMIN.

153A 3' - 0" 6' - 8" EMETAL

HM ENTRY (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

153B 10' - 0" 7' - 0" F METAL ROLL UP

154 3' - 0" 7' - 0" E METAL HM FS RISER

155A 3' - 0" 7' - 0" G MAPLE HM HALLWAY

155B 3' - 0" 7' - 0" J WD/RIFT OAK HM OFFICE

155C 3' - 0" 7' - 6" D HM HM ENTRY FINISH TO MATCH WINDOW FINSH

156 3' - 0" 7' - 0" EMETAL

HM ENTRY (E) MTL DOOR TO BE REFINISHED. FINISH TO MATCH FINISH OF OVERHEAD

DOORS

157 3' - 5 1/4" 6' - 11 1/2" I MAPLE CALL CENTER AD SYSTEMS EXAM SLIDE

158 3' - 0" 7' - 0" N WD/RIFT OAK HM OFFICE

161 3' - 0" 7' - 0" G WD/PAINT HM STORAGE

162 3' - 0" 7' - 0" G WD/PAINT HM NURSING RM

163 3' - 0" 7' - 0" G WD/RIFT OAK HM RESTROOM

WINDOW + RELITE SCHEDULE

TYPE COUNT TYPE HEIGHT WIDTH COMMENTS

A 14 PICTURE 8' - 9" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

B 26 PICTURE 6' - 3" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

C 52 PICTURE 2' - 6" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

D 17 PICTURE 6' - 4 3/4" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

E 26 PICTURE 3' - 10 3/4" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

H 1 PICTURE 5' - 6" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

J 2 PICTURE 5' - 3 1/2" 5' - 3 1/2" HEAD HEIGHT 9'-0", TYP.

K 3 PICTURE 8' - 8 3/4" 4' - 0" HEAD HEIGHT 9'-0", TYP.

L 2 PICTURE 8' - 9" 4' - 6" HEAD HEIGHT 9'-0", TYP.

M 2 PICTURE 8' - 9" 7' - 0" HEAD HEIGHT 9'-0", TYP.

N 1 PICTURE 6' - 4 3/4" 7' - 0" HEAD HEIGHT 9'-0", TYP.

O 2 PICTURE 6' - 4 3/4" 4' - 0" HEAD HEIGHT 9'-0", TYP.

P 1 PICTURE 8' - 7 3/4" 5' - 3" HEAD HEIGHT 9'-0", TYP.

R1 2 RELITE 1' - 6" 5' - 3" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

R2 3 RELITE 1' - 6" 5' - 4" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

R3 46 RELITE 1' - 6" 6' - 6 1/2" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

R4 18 RELITE 3' - 0" 3' - 0" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

R5 10 RELITE 1' - 6" 3' - 3" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

R6 3 RELITE 3' - 9" 4' - 9" HEAD HEIGHT: SEE INTERIOR ELEVATIONS

1

Page 24: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 08-34-00

SPECIAL FUNCTION DOORS 08-34-00-1

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 08-34-00-1

PART 1 GENERAL

1.01 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and

Supplementary Conditions and Division 01 Specification Sections, apply to this

Section.

1.02 SUMMARY

A. Section includes:

1. Interior Aluminum-Framed Top-Hung Sliding Doors

B. Related Sections:

1. Section 08 14 16 – Flush Wood Door

2. Section 08 13 16 – Aluminum Doors

1.03 REFERENCES

A. ANSI – American National Standards Institute

1. ANSI 156.18 Materials and Finishes

2. ANSI A117.1 Specifications for making buildings and facilities usable by

physically handicapped people.

B. BHMA – Builders Hardware Manufacturers Association

C. DHI – Door and Hardware Institute

D. NFPA – National Fire Protection Association

1. NFPA 80 – Fire Doors and Windows

2. NFPA 101 – Life Safety code

3. NFPA 105 – Smoke and Draft Control Door Assemblies

4. NFPA 252 – Fire Tests of Doors Assemblies

E. AWS – Architectural Woodwork Standards

1.04 SUBMITTALS

A. Comply with Section 01 33 00 – Submittal Procedures

Page 25: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 08-34-00

SPECIAL FUNCTION DOORS 08-34-00-2

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 08-34-00-2

B. Product Data: Submit manufacturer’s product data, including installation instructions.

C. Shop Drawings: Submit manufacturer’s shop drawings, including plans, elevations,

sections, and details, indicating dimensions, tolerances, materials, components,

hardware, finish, options, and accessories. Shop Drawings to show required blocking

by others.

D. Samples: Submit manufacturer’s samples of the following sliding door components:

1. Door veneer or laminate sample.

2. Aluminum Frame finish sample.

E. Manufacturer’s Certification: Submit manufacturer’s certification that materials

comply with specified requirements and are suitable for intended application.

F. Warranty Documentation: Submit manufacturer’s standard warranty.

G. Test Reports: Submit acoustical reports or UL1784 as applicable.

1.05 QUALITY ASSURANCE

A. Product Options: Drawings indicate size, profiles, and dimensional requirements of

interior aluminum frames and doors.

B. Source: Obtain sliding aluminum framed doors and hardware from single source.

C. Manufacturer's Qualifications: Manufacturer regularly engaged for past 5 years in

manufacture of sliding doors similar to that specified.

1.06 PERFORMANCE

A. Aluminum perimeter frames with integral acoustic seals.

B. Soft self-closing mechanism integrated with top track.

C. Concealed door guide.

1.07 DELIVERY, STORAGE, AND HANDLING

A. Delivery and Acceptance Requirements: Deliver materials to site in manufacturer’s

original, unopened containers and packaging, with labels clearly identifying product

name and manufacturer.

B. Notify manufacturer immediately of any shipping damage.

C. Storage and Handling Requirements:

Page 26: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 08-34-00

SPECIAL FUNCTION DOORS 08-34-00-3

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 08-34-00-3

1. Store and handle materials in accordance with manufacturer’s instructions.

2. Keep materials in manufacturer’s original, unopened containers and

packaging until installation.

3. Store materials in clean, dry area indoors.

4. Protect materials and finish during storage, handling, and installation to

prevent damage.

PART 2 PRODUCTS

1.08 MANUFACTURERS

A. AD SYSTEMS 2201 100th St. SW, Everett, WA 98204 | Website:

http://specADsystems.com | Phone: 425-374-1360 | Attn: Estimating:

[email protected]

1.09 INTERIOR SLIDING ALUMINUM-FRAMED DOORS AND PARTITIONS

A. Manufacturer:

1. Scheduled Manufacturer: ExamSlide™ High Performance Barn (Sliding)

Door System by AD Systems.

2. Acceptable Substitute: No Substitution.

B. Specified Wall Thickness: 4-7/8”

C. Frame Profiles: Extruded aluminum frame “wrap” frame with integral vertical jamb

(stile pocket).

D. Finish:

1. Standard: Painted Hardcoat (Kynar) Finish. Meets AAMA 2604 Standard

Colors: Light Sequin 789G048

E. Door Leafs. All Doors to be factory machined for hardware including pilot and

function holes.

1. 1-3/4" Flush Wood Door: Reference Spec Section 08 21 00 Wood Doors.

F. Door Components:

1. Single Top Track: AD Systems extruded aluminum track by AD Systems

2. Valances: Extruded aluminum with integral end caps

a. Valance painted to match frame Light Sequin

3. Top Rollers: tandem nylon roller sized to match door weight.

Page 27: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 08-34-00

SPECIAL FUNCTION DOORS 08-34-00-4

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 08-34-00-4

4. Concealed Floor Guide: Integral Jamb floor guide by AD Systems.

5. Soft-Closer: Soft and self-closing damper mechanism at both sides of door

leaf

6. Pull Handles:

a. AD Systems Standard Ladder Pull: 16” long x 1” diameter. Finish: US32D

Satin Stainless Steel.

G. Automatic Door Bottom for improved acoustical performance.

H. Additional hardware functionality can be accommodated. Please contact AD Systems

with your hardware requirements and we evaluate system compatibility and create

specification language.

PART 2 EXECUTION

1.10 EXAMINATION

A. Examine wall openings to receive sliding doors for plumb, level, and square. Note:

Finish door operation will be affected by out of tolerance framing.

B. Verify dimensions of wall openings.

C. Examine surfaces to receive top and bottom guide.

D. Notify Architect of conditions that would adversely affect installation or subsequent

use of sliding doors.

E. Do not begin installation until unacceptable conditions are corrected.

F. Base of door side to be flush or minimal. Rubber Base acceptable.

1.11 INSTALLATION

A. Install sliding doors in accordance with manufacturer’s instructions at locations

indicated on the Drawings.

B. Install sliding doors plumb, level, square, and in proper alignment.

C. Install sliding doors to close against walls without gaps.

D. Install sliding doors to open and close smoothly.

E. Anchor sliding doors securely in place to supports. Required: Fire treated 2 x 6

blocking required full length of track.

Page 28: EVERGREEN FAMILY & WOMENS HEALTH · evergreen family & womens health 1937 west harvard roseburg or 97471 addendum #1 date issued: april 4 2019 this addendum modifies the bidding documents

SECTION 08-34-00

SPECIAL FUNCTION DOORS 08-34-00-5

EVERGREEN FAMILY & WOMENS HEALTH CLINIC 08-34-00-5

1.12 ADJUSTING

A. Adjust sliding doors for proper operation in accordance with manufacturer’s

instructions.

B. Adjust sliding doors to operate smoothly without binding.

C. Repair minor damages to finish in accordance with manufacturer’s instructions and as

approved by Architect.

1.13 CLEANING

A. Clean sliding doors promptly after installation in accordance with manufacturer’s

instructions.

B. Do not use harsh cleaning materials or methods that could damage materials or finish.

1.14 PROTECTION

A. Protect installed sliding doors from damage during construction.

END OF SECTION