Evidence of Performance Calculation of thermal transmittance Test Report No. 16-002433-PR01 (PB-K20-06-en-01) Ve-PB0-2203-en (01.10.2012) Basis *) EN ISO 10077-2:2012-02 EN ISO 6946:2007-12 SG 06-verpflichtend NB-CPD/SG06/11/083 2011-09 *) Correspond/s to the national standard/s (e.g. DIN EN) Representation Test specimen PK01 154.5 77 71 109 20 35 Further drawings see annex. Instructions for use The results obtained can be used as evidence in accordance with the above basis. Validity The data and results given relate solely to the tested and de- scribed specimen. This test does not allow any statement to be made on further characteristics of the present structure regarding performance and quality. Notes on publication The ift-Guidance Sheet "Condi- tions and Guidance for the Use of ift Test Documents" applies. The document may only be pub- lished in full. Contents The report contains a total of 24 page/s and annexe (24 pages). Client ALUMIL S.A. Industrial Area 61100 Kilkis Greece Product Thermal break metal profiles Profile combination: casement-frame, frame, casement-threshold, casement-mullion Designation SD77 Smart Doors Performance-relevant product details Material Aluminium alloys; Surface treatment powder coat- ed or painted; View width B in mm 71 to 226; Thermal break; Material Polyamide 6.6 with 25% glass fibre; Surface in thermal break untreated; Inlay; Material “Kingspan Kooltherm K3”; Thermal conductivity in W/(mK) 0.021; Inlay foam in glazing rebate / to structure; Material “NO- MATEC XPE Profiles”; Thermal conductivity in W/(mK) 0.038; Casement; width x thickness in mm 76 to129.5 x 77; Frame; width x thickness in mm 70 to 113 x 77; Threshold; width x thickness in mm 22 x 77; Mullion; width x thickness in mm 56 to 93 x 68 to 77; Panel; Construction in mm 3/40/2 to 3/72/2; Material Polyurethane rigid foam / “Neopor Plus EPS 100 THP”; Thermal conductivity in W/(mK) 0.024 / 0.030; Replacement panel; Edge cover in mm 0 to 22; Thickness in mm 35 to 77 Special features -/- Results Calculation of thermal transmittance according to EN ISO 10077-2:2012-02 and EN ISO 6946:2007-12 U f = 0.9 to 1.9 W/(m²K) U p = 0.32 to 0.67 W/(m²K) Ψ p = 0,0020 to 0.026 W/(mK) ift Rosenheim 12.10.2016 Konrad Huber, Dipl.-Ing. (FH) Till Stübben, Dipl.-Ing. (FH) Head of Testing Department operating testing officer Building Physics Building Physics

Upload: others

Post on 05-Mar-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Evidence of Performance Calculation of thermal transmittance

Test Report

No. 16-002433-PR01 (PB-K20-06-en-01)

Ve

-PB

0-2

203

-en

(0

1.1

0.2

012

)

Basis *)

EN ISO 10077-2:2012-02

EN ISO 6946:2007-12

SG 06-verpflichtend NB-CPD/SG06/11/083 2011-09

*) Correspond/s to the national standard/s (e.g. DIN EN)

Representation

Test specimen PK01

154.5

77

71

109

20

35 Further drawings see annex.

Instructions for use

The results obtained can be used as evidence in accordance with

the above basis.

Validity

The data and results given relate

solely to the tested and de-scribed specimen. This test does not allow any statement to be

made on further characteristics of the present structure regarding performance and quality.

Notes on publication

The ift-Guidance Sheet "Condi-tions and Guidance for the Use

of ift Test Documents" applies. The document may only be pub-lished in full.

Contents

The report contains a total of 24 page/s and annexe (24 pages).

Client ALUMIL S.A. Industrial Area 61100 Kilkis Greece

Product Thermal break metal profiles Profile combination: casement-frame, frame, casement-threshold, casement-mullion

Designation SD77 Smart Doors

Performance-relevant

product details

Material Aluminium alloys; Surface treatment powder coat-ed or painted; View width B in mm 71 to 226; Thermal break; Material Polyamide 6.6 with 25% glass fibre; Surface in thermal break untreated; Inlay; Material “Kingspan Kooltherm K3”; Thermal conductivity in W/(mK) 0.021; Inlay foam in glazing rebate / to structure; Material “NO-MATEC XPE Profiles”; Thermal conductivity in W/(mK) 0.038; Casement; width x thickness in mm 76 to129.5 x 77; Frame; width x thickness in mm 70 to 113 x 77; Threshold; width x thickness in mm 22 x 77; Mullion; width x thickness in mm 56 to 93 x 68 to 77; Panel; Construction in mm 3/40/2 to 3/72/2; Material Polyurethane rigid foam / “Neopor Plus EPS 100 THP”; Thermal conductivity in W/(mK) 0.024 / 0.030; Replacement panel; Edge cover in mm 0 to 22; Thickness in mm 35 to 77

Special features -/-

Results

Calculation of thermal transmittance according to EN ISO 10077-2:2012-02 and EN ISO 6946:2007-12

Uf = 0.9 to 1.9 W/(m²K)

Up = 0.32 to 0.67 W/(m²K)

Ψp = 0,0020 to 0.026 W/(mK)

ift Rosenheim

12.10.2016

Konrad Huber, Dipl.-Ing. (FH) Till Stübben, Dipl.-Ing. (FH) Head of Testing Department operating testing officer Building Physics Building Physics

Evidence of Performance Page 2 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

1 Object

1.1 Description of test specimen

Thermal break metal profiles

Profile combination: casement-frame, frame, casement-threshold, casement-mullion

Manufacturer Alumil S.A.

System designation SD77 Smart Doors

Material aluminium alloys

Surface treatment powder coated or painted

Sealing system 1 x external, 1 x centre, 1 x internal

at bottom: 1 x centre, 1 x external or internal

Thermal break

Material Polyamide 6.6 with 25% glass fibre

Surface in thermal break untreated

Inlay foam in glazing rebate /

to structure

Material “Nomatec XPE profiles”

Item number 290.77.003.00 / 313.05.250.00

Width in mm 10 / 5

Thickness in mm 29.5 / 25

Thermal conductivity in W/(mK) 0.038

Inlay in thermal break

Material Phenolic resin hard foam “Kingspan Kooltherm K3”

Thermal conductivity in W/(mK) 0.021

Panel

Face layer

Material Aluminium alloys

Type 1

Thickness in mm 45

Construction in mm 3/40/2

Inlay

Material Polyurethane rigid foam

Thermal conductivity in W/(mK) 0,024

Type 2

Thickness in mm 77

Construction in mm 3/72/2

Inlay

Material Polyurethane rigid foam

Thermal conductivity in W/(mK) 0,024

Evidence of Performance Page 3 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Type 3

Thickness in mm 45

Construction in mm 3/40/2

Inlay

Material Expanded polystyrene “Neopor Plus EPS 100 THP”

Thermal conductivity in W/(mK) 0,030

Type 4

Thickness in mm 77

Construction in mm 3/72/2

Inlay

Material Expanded polystyrene “Neopor Plus EPS 100 THP”

Thermal conductivity in W/(mK) 0,030

Replacement panel

Length in mm 190

Edge cover in mm 20 / 22 / 0

Thickness in mm 35 / 45 / 77

Evidence of Performance Page 4 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK01 PK02 PK03

Profile combination casement-frame casement-

threshold

casement-frame

View width in mm 155 117 152

Sum b in mm 97.6 55.8 97.6

Ratio b/B 0.63 0.48 0.64

Opening direction inwards inwards inwards

Casement

Item number S77582 S77582 S77868

Profile cross section width

in mm

109 109 106

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 30 32 /30

Distance of metal shells d in mm 25 25 27 / 25

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 22 22 24

Frame / Threshold

Item number S77586 S77774 S77586

Profile cross section width

in mm

71 22 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 1 2

Thickness of bars in mm 1.6 / 1.8 0.95 + 1.2 1.6 / 1.8

Height in mm 34 / 30 34 34 / 30

Distance of metal shells d in mm 28/ 24 28 28/ 24

Inlay in thermal break

Width in mm 38 -/- 38

Thickness in mm 16 -/- 16

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 35 35 45

Evidence of Performance Page 5 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK04 PK05 PK06

Profile combination casement-frame casement-

threshold

casement-frame

View width in mm 152 114 130

Sum b in mm 97.6 55.8 97.6

Ratio b/B 0.64 0.49 0.75

Opening direction inwards inwards inwards

Casement

Item number S77868 S77868 S77030

Profile cross section width

in mm

106 106 129.5

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 32 /30 32 /30 30

Distance of metal shells d in mm 27 / 25 27 / 25 25

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 24 24 24

Frame / Threshold

Item number S77586 S77774 S77586

Profile cross section width

in mm

71 22 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 1 2

Thickness of bars in mm 1.6 / 1.8 0.95 + 1.2 1.6 / 1.8

Height in mm 34 / 30 34 34 / 30

Distance of metal shells d in mm 28/ 24 28 28/ 24

Inlay in thermal break

Width in mm 38 -/- 38

Thickness in mm 16 -/- 16

Panel

Type Type 1 -/- -/-

Replacement panel

Thickness in mm -/- 45 77

Evidence of Performance Page 6 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK07 PK08 PK09

Profile combination casement-frame casement-

threshold

casement-frame

View width in mm 130 92 155

Sum b in mm 97.6 55.8 97.6

Ratio b/B 0.75 0.61 0.63

Opening direction inwards inwards outward

Casement

Item number S77030 S77030 S77584

Profile cross section width

in mm

129.5 129.5 109

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 30 30 / 22

Distance of metal shells d in mm 25 25 25 / 17

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 24 24 14

Frame / Threshold

Item number S77586 S77774 S77586

Profile cross section width

in mm

71 22 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 1 2

Thickness of bars in mm 1.6 / 1.8 0.95 + 1.2 1.6 / 1.8

Height in mm 34 / 30 34 34 / 30

Distance of metal shells d in mm 28/ 24 28 28/ 24

Inlay in thermal break

Width in mm 38 -/- 38

Thickness in mm 16 -/- 16

Panel

Type Type 2 -/- -/-

Replacement panel

Thickness in mm -/- 77 35

Evidence of Performance Page 7 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK10 PK11 PK12

Profile combination casement-

threshold

casement-frame casement-frame

View width in mm 117 152 152

Sum b in mm 55.8 97.6 97.6

Ratio b/B 0.48 0.64 0.64

Opening direction outward outward outward

Casement

Item number S77584 S77884 S77884

Profile cross section width

in mm

109 106 106

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 / 22 30 / 22 30 / 22

Distance of metal shells d in mm 25 / 17 25 / 15 25 / 15

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 14 14 14

Frame / Threshold

Item number S77774 S77586 S77586

Profile cross section width

in mm

22 71 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 1 2 2

Thickness of bars in mm 0.95 + 1.2 1.6 / 1.8 1.6 / 1.8

Height in mm 34 34 / 30 34 / 30

Distance of metal shells d in mm 28 28/ 24 28/ 24

Inlay in thermal break

Width in mm -/- 38 38

Thickness in mm -/- 16 16

Panel

Type -/- -/- Type 1

Replacement panel

Thickness in mm 35 45 -/-

Evidence of Performance Page 8 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK13 PK14 PK15

Profile combination casement-

threshold

casement-frame casement-frame

View width in mm 114 130 130

Sum b in mm 55.8 97.6 97.6

Ratio b/B 0.49 0.75 0.75

Opening direction outward outward outward

Casement

Item number S77884 S77030 S77030

Profile cross section width

in mm

106 129.5 129.5

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 / 22 30 30

Distance of metal shells d in mm 25 / 15 25 25

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 14 24 24

Frame / Threshold

Item number S77774 S77586 S77586

Profile cross section width

in mm

22 71 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 1 2 2

Thickness of bars in mm 0.95 + 1.2 1.6 / 1.8 1.6 / 1.8

Height in mm 34 34 / 30 34 / 30

Distance of metal shells d in mm 28 28/ 24 28/ 24

Inlay in thermal break

Width in mm -/- 38 38

Thickness in mm -/- 16 16

Panel

Type -/- -/- Type 2

Replacement panel

Thickness in mm 45 77 -/-

Evidence of Performance Page 9 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK16 PK17 PK18

Profile combination casement-

threshold

casement-

mullion

casement-

mullion

View width in mm 92 223 217

Sum b in mm 55.8 135.3 135.3

Ratio b/B 0.61 0.61 0.62

Opening direction outward inwards inwards

Casement 2 x 2 x

Item number S77030 S77582 S77868

Profile cross section width

in mm

129.5 109 106

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 30 32 /30

Distance of metal shells d in mm 25 24.6 27 / 25

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 24 22 24

Frame / Threshold / Mullion

Item number S77774 S77656 S77656

Profile cross section width

in mm

22 56 56

Profile cross section thickness

in mm

77 68 68

Thermal break

Number of bars 1 2 2

Thickness of bars in mm 0.95 + 1.2 1.6 / 1.8 1.6 / 1.8

Height in mm 34 34 / 30 34 / 30

Distance of metal shells d in mm 28 28 / 24 28 / 24

Inlay in thermal break

Width in mm -/- 20 20

Thickness in mm -/- 16 16

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 77 35 45

Evidence of Performance Page 10 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK19 PK20 PK21

Profile combination casement-

mullion

casement-

mullion

casement-

mullion

View width in mm 173 223 217

Sum b in mm 135.3 130.4 130.4

Ratio b/B 0.94 0.58 0.60

Opening direction inwards outward outward

Casement

Item number S77030 S77584 S77884

Profile cross section width

in mm

129.5 109 106

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 1.8 + 0.9

Height in mm 30 30 / 22 30 / 22

Distance of metal shells d in mm 25 25 / 17 25 / 15

Inlay in thermal break

Width in mm 46 46 46

Thickness in mm 24 14 14

Frame / Threshold / Mullion

Item number S77656 S77656 S77656

Profile cross section width

in mm

56 56 56

Profile cross section thickness

in mm

68 68 68

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.6 / 1.8 1.6 / 1.8 1.6 / 1.8

Height in mm 34 / 30 34 / 30 34 / 30

Distance of metal shells d in mm 28 / 24 28 / 24 28 / 24

Inlay in thermal break

Width in mm 20 20 20

Thickness in mm 16 16 16

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 77 35 45

Evidence of Performance Page 11 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK22 PK23 PK24

Profile combination casement-

mullion

frame Casement-

mullion-frame

View width in mm 173 71 226

Sum b in mm 130.4 36 133.8

Ratio b/B 0.75 0.51 0.59

Opening direction outward -/- inwards

Casement

Item number S77030 -/- S77582

Profile cross section width

in mm

129.5 -/- 109

Profile cross section thickness

in mm

77 -/- 77

Thermal break

Number of bars 2 -/- 2

Thickness of bars in mm 1.8 + 0.9 -/- 1.8 + 0.9

Height in mm 30 -/- 30

Distance of metal shells d in mm 25 -/- 25

Inlay in thermal break

Width in mm 46 -/- 46

Thickness in mm 24 -/- 22

Frame / Threshold / Mullion 2 x

Item number S77656 S77514 S77514 / S77586

Profile cross section width

in mm

56 71 71

Profile cross section thickness

in mm

68 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.6 / 1.8 1.8 1.8 / 1.6

Height in mm 34 / 30 40 40 / 34 /30

Distance of metal shells d in mm 28 / 24 34 34 / 28 / 24

Inlay in thermal break

Width in mm 20 33 33 / 38

Thickness in mm 16 26 26 / 16

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 77 35 35

Evidence of Performance Page 12 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK25 PK26 PK27

Profile combination casement-frame frame casement-

mullion

View width in mm 153 113 178

Sum b in mm 76.9 78.2 82.3

Ratio b/B 0.50 0.69 0.46

Opening direction inwards -/- inwards

Casement

Item number S77582 -/- S77582

Profile cross section width

in mm

109 -/- 109

Profile cross section thickness

in mm

77 -/- 77

Thermal break

Number of bars 2 -/- 2

Thickness of bars in mm 1.8 + 0.9 -/- 1.8 + 0.9

Height in mm 30 -/- 30

Distance of metal shells d in mm 25 -/- 25

Inlay in thermal break

Width in mm 46 -/- 46

Thickness in mm 22 -/- 22

Frame / Threshold / Mullion

Item number S77510+S77982 S77906 S77564+S77982

Profile cross section width

in mm

70 113 95

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 3 2 3

Thickness of bars in mm 1.8 /1.6 1.8 1.8 / 1.6

Height in mm 40 / 34 40 40 / 34

Distance of metal shells d in mm 34 / 28 34 34 / 28

Inlay in thermal break

Width in mm 23 75 23

Thickness in mm 26 26 26

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 35 35 35

Evidence of Performance Page 13 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK28 PK29 PK30

Profile combination casement-frame casement-

mullion

casement-frame

View width in mm 117 177 150

Sum b in mm 66.8 97.6 109.9

Ratio b/B 0.57 0.55 0.73

Opening direction -/- inward -/-

Casement

Item number S77880 S77582 S77644

Profile cross section width

in mm

115 109 76

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.4 1.8 + 0.9 1.8 / 2.0

Height in mm 28 30 40 / 38

Distance of metal shells d in mm 22 25 34 / 32

Inlay in thermal break

Width in mm 64 46 42

Thickness in mm 13 22 24

Frame / Threshold / Mullion

Item number S77774 S77586 S77886

Profile cross section width

in mm

22 93 74

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 1 2 2

Thickness of bars in mm 0.95 + 1.2 1.6 / 1.8 1.8

Height in mm 34 34 / 30 40

Distance of metal shells d in mm 28 28/ 24 34

Inlay in thermal break

Width in mm -/- 38 61

Thickness in mm -/- 16 26

Panel

Type -/- -/- -/-

Replacement panel

Thickness in mm 35 35 35

Evidence of Performance Page 14 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK31 PK32 PK33

Profile combination casement-frame casement-frame casement-frame

View width in mm 99 152 130

Sum b in mm 64.2 97.6 97.6

Ratio b/B 0.65 0.64 0.75

Opening direction -/- inwards inwards

Casement

Item number -/- S77868 S77030

Profile cross section width

in mm

-/- 106 129.5

Profile cross section thickness

in mm

-/- 77 77

Thermal break

Number of bars -/- 2 2

Thickness of bars in mm -/- 1.8 + 0.9 1.8 + 0.9

Height in mm -/- 32 /30 30

Distance of metal shells d in mm -/- 27 / 25 25

Inlay in thermal break

Width in mm -/- 46 46

Thickness in mm -/- 24 24

Frame / Threshold / Mullion

Item number S77886 S77586 S77586

Profile cross section width

in mm

99 71 71

Profile cross section thickness

in mm

77 77 77

Thermal break

Number of bars 2 2 2

Thickness of bars in mm 1.8 1.6 / 1.8 1.6 / 1.8

Height in mm 40 34 / 30 34 / 30

Distance of metal shells d in mm 34 28/ 24 28/ 24

Inlay in thermal break

Width in mm 61 38 38

Thickness in mm 26 16 16

Panel

Type -/- Type 3 Type 4

Replacement panel

Thickness in mm 35 -/-

Evidence of Performance Page 15 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK34 PK35 PK36

Profile combination casement-frame casement-frame Panel

View width in mm 152 130 -/-

Sum b in mm 97.6 97.6 -/-

Ratio b/B 0.64 0.75 -/-

Opening direction outward outward -/-

Casement

Item number S77884 S77030 -/-

Profile cross section width

in mm

106 129.5 -/-

Profile cross section thickness

in mm

77 77 -/-

Thermal break

Number of bars 2 2 -/-

Thickness of bars in mm 1.8 + 0.9 1.8 + 0.9 -/-

Height in mm 30 / 22 30 -/-

Distance of metal shells d in mm 25 / 15 25 -/-

Inlay in thermal break

Width in mm 46 46 -/-

Thickness in mm 14 24 -/-

Frame / Threshold

Item number S77586 S77586 -/-

Profile cross section width

in mm

71 71 -/-

Profile cross section thickness

in mm

77 77 -/-

Thermal break

Number of bars 2 2 -/-

Thickness of bars in mm 1.6 / 1.8 1.6 / 1.8 -/-

Height in mm 34 / 30 34 / 30 -/-

Distance of metal shells d in mm 28/ 24 28/ 24 -/-

Inlay in thermal break

Width in mm 38 38 -/-

Thickness in mm 16 16 -/-

Panel

Type Type 3 Type 4 Type 1

Replacement panel

Thickness in mm -/- -/- -/-

Evidence of Performance Page 16 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Test specimen PK37 PK38 PK39

Profile combination Panel Panel Panel

View width in mm -/- -/- -/-

Sum b in mm -/- -/- -/-

Ratio b/B -/- -/- -/-

Opening direction -/- -/- -/-

Casement

Item number -/- -/- -/-

Profile cross section width

in mm

-/- -/- -/-

Profile cross section thickness

in mm

-/- -/- -/-

Thermal break

Number of bars -/- -/- -/-

Thickness of bars in mm -/- -/- -/-

Height in mm -/- -/- -/-

Distance of metal shells d in mm -/- -/- -/-

Inlay in thermal break

Width in mm -/- -/- -/-

Thickness in mm -/- -/- -/-

Frame / Threshold

Item number -/- -/- -/-

Profile cross section width

in mm

-/- -/- -/-

Profile cross section thickness

in mm

-/- -/- -/-

Thermal break

Number of bars -/- -/- -/-

Thickness of bars in mm -/- -/- -/-

Height in mm -/- -/- -/-

Distance of metal shells d in mm -/- -/- -/-

Inlay in thermal break

Width in mm -/- -/- -/-

Thickness in mm -/- -/- -/-

Panel

Type Type 2 Type 3 Type 4

Replacement panel

Thickness in mm -/- -/- -/-

Evidence of Performance Page 17 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

The description is based on specifications provided by the client and on inspection of the test specimen at the ift. (Item des-ignations/ numbers as well as material specifications were provided by the client, unless designated as „ift-tested“.)

Test specimen are described in the annex "Product/Sample description".

1.2 Sampling

The following data for sampling have been presented to ift:

Sampler: ALUMIL S.A., 61100 Kilkis (Greece)

Datum: 14.09.2016

Documentation: ift Rosenheim did not receive a sampling report.

ift-test specimen-No.: 16-002433-PK01

Evidence of Performance Page 18 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

2 Procedure

2.1 Basic documents *) of the processes

EN ISO 10077-2:2012-02

Thermal performance of windows, doors and shutters - Calculation of thermal transmit-

tance - Part 2 - Numerical method for frames

EN ISO 6946:2007-12

Building components and building elements - Thermal resistance and thermal transmit-

tance - Calculation method

SG 06-verpflichtend NB-CPD/SG06/11/083 2011-09

EN 14351-1:2006 Treatment of unventilated rectangular cavities when calculating thermal

properties to EN ISO 10077-2

*) correspond/s to the national standard/s, e.g. DIN EN

2.2 Short description of process

Calculation of thermal transmittance and linear thermal transmittance Uf / Ψ

The profile section is subdivided into a sufficient number of elements; with subdivision into smaller elements not having any effect on the total heat flow. The relevant mate-rials / boundary conditions are determined and the total heat flow calculated. The heat flow is used to determine the thermal transmittance and the linear thermal transmit-tance. Calculation of thermal transmittance Up

The thermal transmittance of a panel with several homogeneous layers, lying in a row, is calculated from the inverse of the sum of the thermal resistance of the individ-ual layers and the internal and external surface resistance.

Evidence of Performance Page 19 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

3 Detailed results

Evidence of Performance Page 20 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Evidence of Performance Page 21 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Evidence of Performance Page 22 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Evidence of Performance Page 23 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

Evidence of Performance Page 24 of 24

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

1-3

314

-en

()0

1.0

7.2

013

3.1 Summary of test results

Annex 1: Product illustration Page 1 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

154.5

77

71

109

20

35

Figure 01: Cross section test specimen PK01 Figure 02: Simulation model test specimen PK01

35

20

117

22

77

109

Figure 03: Cross section test specimen PK02 Figure 04: Simulation model test specimen PK02

Annex 1: Product illustration Page 2 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

71

22

152

45

106

Figure 05: Cross section test specimen PK03 Figure 06: Simulation model test specimen PK03

Figure 07: Simulation model test specimen PK04

Ψ - calculation

Figure 08: Simulation model test specimen PK32

Ψ - calculation

Annex 1: Product illustration Page 3 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

22

45

106

114

22

Figure 09: Cross section test specimen PK05 Figure 10: Simulation model test specimen PK05

Annex 1: Product illustration Page 4 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

77

84

130

71

Figure 11: Cross section test specimen PK06 Figure 12: Simulation model test specimen PK06

Uf – calculation

Figure 13: Simulation model test specimen PK07

Ψ - calculation

Figure 14: Simulation model test specimen PK33

Ψ - calculation

Annex 1: Product illustration Page 5 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

84

22

92

Figure 15: Cross section test specimen PK08

Figure 16: Simulation model test specimen PK08

20

77

71

155

35

109

Figure 17: Cross section test specimen PK09 Figure 18: Simulation model test specimen PK09

Annex 1: Product illustration Page 6 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

35

20

117

109

77

22

Figure 19: Cross section test specimen PK10 Figure 20: Simulation model test specimen PK10

Annex 1: Product illustration Page 7 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

22

45

71

152

106

Figure 21: Cross section test specimen PK11 Figure 22: Simulation model test specimen PK11

Uf - calculation

Figure 23: Simulation model test specimen PK12

Ψ - calculation

Figure 24: Simulation model test specimen PK34

Ψ - calculation

Annex 1: Product illustration Page 8 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

78

22

45

114

22

106

Figure 25: Cross section test specimen PK13 Figure 26: Simulation model test specimen PK13

Annex 1: Product illustration Page 9 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

77

84

129

71

Figure 27: Cross section test specimen PK14

Figure 28: Simulation model test specimen PK14

Uf - calculation

Figure 29: Simulation model test specimen PK15

Ψ - calculation

Figure 30: Simulation model test specimen PK35

Ψ - calculation

Annex 1: Product illustration Page 10 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

84

92

22

Figure 31: Cross section test specimen PK16 Figure 32: Simulation model test specimen PK16

Annex 1: Product illustration Page 11 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

20

35

223

56

77

109 109

20

68

Figure 33: Cross section test specimen PK17

Figure 34: Simulation model test specimen PK17

Annex 1: Product illustration Page 12 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

22

56

217

106

77

22

106

45

68

Figure 35: Cross section test specimen PK18

Figure 36: Simulation model test specimen PK18

Annex 1: Product illustration Page 13 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

56

84

77

173

84

68

Figure 37: Cross section test specimen PK19

Figure 38: Simulation model test specimen PK19

Annex 1: Product illustration Page 14 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

20

35

223

109

77

56

68

20

Figure 39: Cross section test specimen PK20

Figure 40: Simulation model test specimen PK20

Annex 1: Product illustration Page 15 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

84

22 56

45

78

217

106

68

22

Figure 41: Cross section test specimen PK21

Figure 42: Simulation model test specimen PK21

Annex 1: Product illustration Page 16 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

84

56

77

173

84

68

Figure 43: Cross section test specimen PK22

Figure 44: Simulation model test specimen PK22

Annex 1: Product illustration Page 17 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

7 7

35

15

71

Figure 45: Cross section test specimen PK23 Figure 46: Simulation model test specimen PK23

Annex 1: Product illustration Page 18 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

15

71

20

35

77

109

226

71

35

Figure 47: Cross section test specimen PK24

Figure 48: Simulation model test specimen PK24

Annex 1: Product illustration Page 19 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

77

70

35

20

109

153

Figure 49: Cross section test specimen PK25 Figure 50: Simulation model test specimen PK25

35

15

77

113

Figure 51: Cross section test specimen PK26 Figure 52: Simulation model test specimen PK26

Annex 1: Product illustration Page 20 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

35

15 20

178

109

95

77

35

Figure 53: Cross section test specimen PK27

Figure 54: Simulation model test specimen PK27

Annex 1: Product illustration Page 21 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

35

20

77

117

Figure 55: Cross section test specimen PK28 Figure 56: Simulation model test specimen PK28

Annex 1: Product illustration Page 22 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

17 20

109

93

176

35

77

Figure 57: Cross section test specimen PK29

Figure 58: Simulation model test specimen PK29

Annex 1: Product illustration Page 23 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

35

77

20

150

74

76

Figure 59: Cross section test specimen PK30 Figure 60: Simulation model test specimen PK30

35

15

99

77

Figure 61: Cross section test specimen PK31 Figure 62: Simulation model test specimen PK31

Annex 1: Product illustration Page 24 of 24

Evidence of Performance

Calculation of thermal transmittance

Test Report No. 16-002433-PR01 (PB-K20-06-en-01) dated 12.10.2016

Client: ALUMIL S.A., 61100 Kilkis (Greece)

Ve

-PB

5-3

316

-en

(01

.07

.201

3)

3

40

2

45

3

72

2

77

Figure 63: Cross section test specimen PK36 / PK38

Figure 64: Cross section test specimen PK37 / PK39