evitherm evitherm bruno hay 16/09/2003 task 4.1 : best practice guides compile information on...

22
EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides Compile information on measurement methods and laboratories Direct the Evitherm user quickly to this information A user of Evitherm could find on our website : Information on measurement techniques of thermophysical properties Information on method to calibrate his own equipment a help to choose : - the measurement technique suitable to his problem - a list of laboratories using this relevant technique 1

Upload: thomas-waters

Post on 18-Jan-2018

219 views

Category:

Documents


0 download

DESCRIPTION

Scheme for guiding Evitherm user to measurement method or laboratories Physical properties Thermal diffusivity EVITherM Bruno HAY 16/09/2003 Specific heat Thermal conductivity E missivity 1 Information on measurement and calibration techniques, laboratories and equipment suppliers … Thermal expansion 3

TRANSCRIPT

Page 1: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

EVITherM

EVITherM Bruno HAY 16/09/2003

Task 4.1 : Best Practice Guides

Compile information on measurement methods and

laboratories

Direct the Evitherm user quickly to this information

A user of Evitherm could find on our website :

Information on measurement techniques of thermophysical properties

Information on method to calibrate his own equipment

a help to choose :

- the measurement technique suitable to his problem

- a list of laboratories using this relevant technique

1

Page 2: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

1

Scheme for guiding Evitherm userto measurement method or laboratories

2

 

  

Search information on measurement and calibration techniques, laboratories and equipment suppliers

Choice of a measurement technique and/or laboratories  

 

EVITherM Bruno HAY 16/09/2003

1

2

Page 3: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

  

Physical properties

Thermal diffusivity

EVITherM Bruno HAY 16/09/2003

Specific heat

Thermal conductivity

Emissivity

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

…Thermal expansion

3

Page 4: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

Measurement techniques

Guarded hot plate

EVITherM Bruno HAY 16/09/2003

Hot wire method

Flash method

Axial heat flow method

Heat flow meter

Radial flow method Comparative method

(P)

(P)

(P)

(S)

(S)

(P)

(P)

P : Primary or absolute method / S : Secondary method

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

4

Page 5: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

Flash method

EVITherM Bruno HAY 16/09/2003

Laboratories

Calibration

Measurement

Apparatus suppliers

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

5

Page 6: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

Flash method – Measurement / Calibration

- Principle of measurement (short description)

- Advantages / Disadvantages

- Range of applicability

EVITherM Bruno HAY 16/09/2003

Guides Standards Databases

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

6

Page 7: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

Laboratories and measurement providers using the flash method

Name Contact Website Country

LNE Bruno Hay www.lne.fr France PTB IKE NPL …

EVITherM Bruno HAY 16/09/2003

12345

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

7

Page 8: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

EVITherM Bruno HAY 16/09/2003

Technique Temperature Range Further information Laser flash technique 20 °C - 1500 °C Uncertainty : 3 % to 5 %

Atmosphere : vacuum, inert gas Cylindrical specimens

Diameter : 10 mm Thickness : from 1 to 4 mm

LABORATOIRE NATIONAL D’ESSAIS

Adress Contact Qualification

29, avenue Roger Hennequin Bruno HAY COFRAC 78197 Trappes Cedex [email protected] NMI France Tel: 33 1 30 69 12 20 Fax: 33 1 30 69 12 34

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

8

Page 9: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

Flash method - Suppliers of apparatus

Name Website Country

Netzsch Gerätebau GmbH www.ngb.netzsch.com Germany

EVITherM Bruno HAY 16/09/2003

1

2

3

4

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

9

Page 10: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

EVITherM Bruno HAY 16/09/2003

Netzsch Gerätebau GmbH

Adress

NETZSCH Gerätebau GmbH Tel +49 9287/881-0 Wittelsbacherstraße 42 Fax +49 9287/881-144 D-95100 Selb/Bayern E-mail:

[email protected]

1 Information on measurement and calibration techniques, laboratories and equipment suppliers

10

Page 11: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

    2 Choice of a measurement technique and/or laboratories

EVITherM Bruno HAY 16/09/2003

Physical properties

Thermal diffusivity

Specific heat

Thermal conductivity

Emissivity

…Thermal expansion

11

Page 12: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

    2 Choice of a measurement technique and/or laboratories

Type of material

Insulating material

EVITherM Bruno HAY 16/09/2003

Ceramics / Glasses

Polymers

Metals / Alloys

… …

12

Page 13: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

    2 Choice of a measurement technique and/or laboratories

Characteristics of the material

EVITherM Bruno HAY 16/09/2003

Liquid

State

Composite

Homogeneity

Porous With coating

Semi-transparent

Transparency

OpaqueSolid Homogeneous

Thin film

Furthercharacteristics

Moisture

Powder

13

Page 14: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

    2 Choice of a measurement technique and/or laboratories

Temperature range

Below RT

EVITherM Bruno HAY 16/09/2003

500 °C - 1500 °C Above 1500 °C

Above 1500 °C500 °C - 1500 °CBelow RT

Minimum

Maximum

Uncertainty

< 2% < 10 % < 15 %< 5%

RT - 500 °C

RT - 500 °C

14

Page 15: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

  

EVITherM Bruno HAY 16/09/2003

2 Choice of a measurement technique and/or laboratories

Summary of the requirements

Physical property Material StateThermal conductivity Metals / Alloys Solid,

homogeneous, opaque

Temperature range Uncertainty

RT to 1500 °C < 5 %

M

1

2

3

Results of the request

Technique Sample Geometry

Laser Flash Technique Cylindrical specimens - Flat and parallel faces Diameter 5 mm to 20 mm - Thickness : 1 mm to 5 mm

Hot Wire Technique Pair of square specimens with grooves - Flat and parallel faces L: 100 mm to 250 mm - W : 30 mm to 100 mm - T : 20 mm to 50 mm

Guarded Hot Plate Pair of cylindrical or square specimens - Flat and parallel faces Diameter or square 100 mm to 500 mm - Thickness : 20 mm to 50 mm

15

Page 16: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

    2 Choice of a measurement technique and/or laboratories

Geographical situation

EVITherM Bruno HAY 16/09/2003

All countries

Austria

England

France

Germany

…Italy

France

Qualification

All laboratories

Certified labs.

NMI’s

Qualified labs.

16

Page 17: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Scheme for guiding Evitherm userto measurement method or laboratories

   

EVITherM Bruno HAY 16/09/2003

Technique Temperature Range Further information Laser flash technique 20 °C - 1500 °C Uncertainty : 3 % to 5 %

Atmosphere : vacuum, inert gas Cylindrical specimens

Diameter : 10 mm Thickness : from 1 to 4 mm

LABORATOIRE NATIONAL D’ESSAIS

Adress Contact Qualification

29, avenue Roger Hennequin Bruno HAY COFRAC 78197 Trappes Cedex [email protected] NMI France Tel: 33 1 30 69 12 20 Fax: 33 1 30 69 12 34

2 Choice of a measurement technique and/or laboratories

17

Page 18: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Selection of measurement methods

Selection of measurement methods

  To propose to a Evitherm user the measurement method suitable to his requirements, we should :

- Fix selection criteria (sample geometry, temperature range, material …)

- Quantify these criteria for each measurement methods

- Define a method allowing to find the suitable method from the criteria

EVITherM Bruno HAY 16/09/2003

18

Page 19: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Selection of measurement methods

EVITherM Bruno HAY 16/09/2003

Table 1 Thermal Conductivity – Measurement MethodsMeasurement

MethodMain type

of materialsTemperature

range Sample geometry Measurement

rangeLaboratoriesAtm.

Flashmethod

[20 - 2000°C]Cylindrical sample

diameter : 5 to 20 mmthickness : 1 to 5 mm

[1-500 W/mK]Inert gasvacuum

air

ARCS, LNE NPL…

OpaqueHomogeneous

Guarded hotplate

OpaqueSemi-transp.

HomogeneousComposites

[20 - 500 °C]2 cylindrical or square samplesflat and parallel faces diameter : 100 to 500 mmThickness : 20 mm to 50 mm

< 1 W/mK air IKE, LNE NPL, PTB…

Hot wiremethod

Refractorymaterials

including powder[20 - 1500 °C]

2 square samples with groovesflat and parallel faces

Length : 100 mm to 250 mmWidth : 30 mm to 100 mm

Thickness : 20 mm to 50 mm

< 5 W/mK air IKE, NPL

PTB…

TemperatureWave method

OpaqueHomogeneous

[20 - 2000 °C]Cylindrical sample

Diameter : 5 mm to 10 mmThickness : 1 mm to 5 mm

[1-500 W/mK]Inert gasvacuum

air IKE

Four ProbeTechnique

ElectricConductingmaterials

[50 - 1200 °C]Cylindrical sampleDiameter : 5.5 mm,

Length : 90 mm [1-500 W/mK] IKE

19

Page 20: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Selection of measurement methods

EVITherM Bruno HAY 16/09/2003

Table 2 Thermal Conductivity – Laboratories

Labs MeasurementMethods

Temp. Range (°C)

Sample geometry

Country

LNE

Cylindrical samplediameter : 10 mm

thickness : 1 to 5 mm

Guarded hotplate

Solid materials (alloys, ceramics

polymers)20

Pair of square samplesflat and parallel facessquare : 500 mmThickness : 20 to 50 mm

Laser flashmethod

Main typeof materials

Solid materials (thermal insulation

products)

min max

1500

-10 60

Uncert. of measur.

5 %to 6 %

0.5 % to 1

%

France

Qualif.

COFRAC NMI

20

Page 21: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Selection of measurement methods

Selection of measurement methods

EVITherM Bruno HAY 16/09/2003

1 - Evitherm user expresses his requirements 

2 - Coherences between the requirements and the characteristics of each method are checked

  3 - The most relevant methods are proposed

21

Page 22: EVITherM EVITherM Bruno HAY 16/09/2003 Task 4.1 : Best Practice Guides  Compile information on measurement methods and laboratories  Direct the Evitherm

Selection of measurement methods

Selection of measurement methods

EVITherM Bruno HAY 16/09/2003

User requirementsState of material

Flash method

Guarded hot plate

Hot wire method

Solid Homog. Opaque

Temperature

1500 °C 1-5 W/mK

Total

1 111 1 5

1 011 0 3

1 011 1 4

22