EVOJET.150kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT1350mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
150kW 740 1455 1315
FEATURES AND BENEFITS
L SIDE300mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 200
Flue Gas Mass Flow Rate kg/sec 0.07
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardCONTROL
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 150kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 510
Boiler Dimensions mm 1315 (H) x 740 (W) x 1455 (D)
Boiler Clearances mm Front: 1350 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 2.0
Furnace Volume dm³ 172
Min Burner Length mm 160
Burner Diameter mm 130
Boiler Output (80/60) kW 146
Boiler Output (50/30) kW 160.5
Boiler Input kW 111
HYDRAULICS
Pressure drop ∆T 10°C mbar 43.2
Pressure drop ∆T 20°C mbar 11.3
Nominal Flow Rate ∆T 10°C l/m 214.4
Nominal Flow Rate ∆T 20°C l/m 107
Min Flow Rate l/s 0.47
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 323
Return High Temperature DN 50
Return Low Temperature DN 65
FLOOR STANDING
** Dependent on return temperature
211182
EVOJET.210kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT1350mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
210kW 740 1455 1315
FEATURES AND BENEFITS
L SIDE300mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 200
Flue Gas Mass Flow Rate kg/sec 0.09
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 210kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 530
Boiler Dimensions mm 1315 (H) x 740 (W) x 1455 (D)
Boiler Clearances mm Front: 1350 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 96.4
Min/Max Gas pressure (Nat Gas) mbar 17.5-20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 2.7
Furnace Volume dm³ 172
Min Burner Length mm 216
Burner Diameter mm 140
Boiler Output (80/60) kW 203.9
Boiler Output (50/30) kW 224.7
Boiler Input kW 151
HYDRAULICS
Pressure drop ∆T 10°C mbar 36.0
Pressure drop ∆T 20°C mbar 10.2
Nominal Flow Rate ∆T 10°C l/m 299.5
Nominal Flow Rate ∆T 20°C l/m 149.4
Min Flow Rate l/s 0.66
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 360
Return High Temperature DN 50
Return Low Temperature DN 65
FLOOR STANDING
211183
** Dependent on return temperature
EVOJET.270kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT1620mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
270kW 850 1630 1450
FEATURES AND BENEFITS
L SIDE300mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 250
Flue Gas Mass Flow Rate kg/sec 0.12
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 270kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 677
Boiler Dimensions mm 1450 (H) x 850 (W) x 1630 (D)
Boiler Clearances mm Front: 1620 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 96.5
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 3.2
Furnace Volume dm³ 241
Min Burner Length mm 216
Burner Diameter mm 140
Boiler Output (80/60) kW 265.1
Boiler Output (50/30) kW 288.9
Boiler Input kW 211
HYDRAULICS
Pressure drop ∆T 10°C mbar 54.0
Pressure drop ∆T 20°C mbar 16.3
Nominal Flow Rate ∆T 10°C l/m 389.4
Nominal Flow Rate ∆T 20°C l/m 194.2
Min Flow Rate l/s 0.86
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 495
Return High Temperature DN 50
Return Low Temperature DN 65
FLOOR STANDING
** Dependent on return temperature
211184
EVOJET.350kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT1820mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
350kW 850 1830 1450
FEATURES AND BENEFITS
L SIDE300mm
** Dependent on return temperature
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 250
Flue Gas Mass Flow Rate kg/sec 0.15
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 350kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 753
Boiler Dimensions mm 1450 (H) x 850 (W) x 1830 (D)
Boiler Clearances mm Front: 1820 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 4.6
Furnace Volume dm³ 279
Min Burner Length mm 216
Burner Diameter mm 140
Boiler Output (80/60) kW 340.9
Boiler Output (50/30) kW 374.5
Boiler Input kW 271
HYDRAULICS
Pressure drop ∆T 10°C mbar 46.4
Pressure drop ∆T 20°C mbar 13.4
Nominal Flow Rate ∆T 10°C l/m 500.7
Nominal Flow Rate ∆T 20°C l/m 249.8
Min Flow Rate l/s 1.11
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 555
Return High Temperature DN 65
Return Low Temperature DN 80
FLOOR STANDING
211185
EVOJET.450kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT1930mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
450kW 900 2035 1630
FEATURES AND BENEFITS
L SIDE300mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 300
Flue Gas Mass Flow Rate kg/sec 0.20
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 450kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 1095
Boiler Dimensions mm 1630 (H) x 900 (W) x 2035 (D)
Boiler Clearances mm Front: 1930 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 5.0
Furnace Volume dm³ 442
Min Burner Length mm 216
Burner Diameter mm 152
Boiler Output (80/60) kW 438.3
Boiler Output (50/30) kW 481.5
Boiler Input kW 351
HYDRAULICS
Pressure drop ∆T 10°C mbar 33.8
Pressure drop ∆T 20°C mbar 9.0
Nominal Flow Rate ∆T 10°C l/m 643.8
Nominal Flow Rate ∆T 20°C l/m 321.1
Min Flow Rate l/s 1.41
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 743
Return High Temperature DN 80
Return Low Temperature DN 100
FLOOR STANDING
** Dependent on return temperature
211186
EVOJET.600kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT2140mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
600kW 900 2235 1630
FEATURES AND BENEFITS
L SIDE300mm
** Dependent on return temperature
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 300
Flue Gas Mass Flow Rate kg/sec 0.26
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 600kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 1250
Boiler Dimensions mm 1630 (H) x 900 (W) x 2235 (D)
Boiler Clearances mm Front: 2140 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 5.5
Furnace Volume dm³ 496
Min Burner Length mm 250
Burner Diameter mm 179
Boiler Output (80/60) kW 584.4
Boiler Output (50/30) kW 642
Boiler Input kW 451
HYDRAULICS
Pressure drop ∆T 10°C mbar 30.2
Pressure drop ∆T 20°C mbar 8.5
Nominal Flow Rate ∆T 10°C l/m 858.3
Nominal Flow Rate ∆T 20°C l/m 428.2
Min Flow Rate l/s 1.88
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 770
Return High Temperature DN 80
Return Low Temperature DN 100
FLOOR STANDING
211187
EVOJET.800kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT2400mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
800kW 1060 2560 1910
FEATURES AND BENEFITS
L SIDE300mm
** Dependent on return temperature
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 350
Flue Gas Mass Flow Rate kg/sec 0.33
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 800kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 1870
Boiler Dimensions mm 1910 (H) x 1060 (W) x 2560 (D)
Boiler Clearances mm Front: 2400 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 5.7
Furnace Volume dm³ 753
Min Burner Length mm 250
Burner Diameter mm 179
Boiler Output (80/60) kW 779.2
Boiler Output (50/30) kW 856
Boiler Input kW 601
HYDRAULICS
Pressure drop ∆T 10°C mbar 128.7
Pressure drop ∆T 20°C mbar 28.7
Nominal Flow Rate ∆T 10°C l/m 1144.5
Nominal Flow Rate ∆T 20°C l/m 570.9
Min Flow Rate l/s 2.52
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 1320
Return High Temperature DN 80
Return Low Temperature DN 125
FLOOR STANDING
211188
EVOJET.1000kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT2700mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
1000kW 1060 2810 1910
FEATURES AND BENEFITS
L SIDE300mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 350
Flue Gas Mass Flow Rate kg/sec 0.43
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 1000kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 2085
Boiler Dimensions mm 1910 (H) x 1060 (W) x 2810 (D)
Boiler Clearances mm Front: 2700 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 6.3
Furnace Volume dm³ 845.0
Min Burner Length mm 250
Burner Diameter mm 179
Boiler Output (80/60) kW 974
Boiler Output (50/30) kW 1070
Boiler Input kW 801
HYDRAULICS
Pressure drop ∆T 10°C mbar 121.5
Pressure drop ∆T 20°C mbar 30.6
Nominal Flow Rate ∆T 10°C l/m 1430.6
Nominal Flow Rate ∆T 20°C l/m 713.6
Min Flow Rate l/s 3.16
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 1395
Return High Temperature DN 80
Return Low Temperature DN 125
FLOOR STANDING
** Dependent on return temperature
211189
EVOJET.1250kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE300mm
REAR1000mm
FRONT2920mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
1250kW 1180 3010 2030
FEATURES AND BENEFITS
L SIDE300mm
** Dependent on return temperature
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 400
Flue Gas Mass Flow Rate kg/sec 0.54
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 1250kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 2515
Boiler Dimensions mm 2030 (H) x 1180 (W) x 3010 (D)
Boiler Clearances mm Front: 2920 Left Side: 300 Right Side: 300 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 6.8
Furnace Volume dm³ 1037.0
Min Burner Length mm 280
Burner Diameter mm 189
Boiler Output (80/60) kW 1217.5
Boiler Output (50/30) kW 1337.5
Boiler Input kW 1001
HYDRAULICS
Pressure drop ∆T 10°C mbar 100.4
Pressure drop ∆T 20°C mbar 28.4
Nominal Flow Rate ∆T 10°C l/m 1788.2
Nominal Flow Rate ∆T 20°C l/m 892.1
Min Flow Rate l/s 3.94
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 1825
Return High Temperature DN 80
Return Low Temperature DN 125
FLOOR STANDING
211190
EVOJET.1450kWCONDENSING PRESSURE JET
The Evojet condensing range of pressure jet boilers are available in 10 models with outputs from 150-1450kW. Floor standing boilers for applications in either single or multiple configurations.
• Up to 109.3% part load efficiency
• Dedicated low temp return
• Stainless steel heat exchanger
• Natural gas & LPG compatible
• Triple flue pass for high operating efficiencies
• Natural gas / LPG burner options - modulating or high / low operation
• Modulation via 0-10 volt BMS, or RWF controller
• Twin return water connections
• High water content
• Pressurised combustion chamber for smooth burner operation
• Stainless steel turbulator for maximum heat transfer and increased efficiency
• Double insulated boiler housing
• Front door inspection without removing burner
• Complete with control panel
IDEAL COMMERCIAL BOILERS
PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN
T: 0844 5436060F: 0844 5436181E: [email protected]
IDEALCOMMERCIALBOILERS.COM
DIMENSIONS AND CLEARANCES
All dimensions in mm* Minimum recommended is the burner length.
The following minimum clearances must be maintained for operation and servicing:
R SIDE600mm
REAR1000mm
FRONT3100mm
For full details of all configurations & specifications, please refer to the Evojet installation manual.
BOILER DIM A DIM B DIM C
1450kW 1225 3080 2180
FEATURES AND BENEFITS
L SIDE600mm
TECHNICAL SPECIFICATIONS.
FLUE/AIR INLET
Flue Size mm 450
Flue Gas Mass Flow Rate kg/sec 0.63
Min-Max Flue Gas Temperature °C 45-75**
ELECTRICAL
Electrical Supply 230 ± 10% 50Hz 1 Ph
Current (Max No Pump) amp 6.3
Power Consumption watt 250
Fuse Rating amp 6.3T
Insulation Class IP X4D
CONTROL/BOILER/BURNER OPERATION
0-10V DC BMS or Siemens RWF Optional
High Limit Protection Standard
Boiler Temperature Gauge Standard
Control Thermostat Sensor Standard
Safety Thermostat Sensor Standard
Two Stage Thermostat StandardBURNER
BURNER MATCHING OPTIONS
NG
LPG
Low NOx
Pre-mix
Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification.
EVOJET 1450kW
W: IDEALCOMMERCIALBOILERS.COM E: [email protected]: 0844 5436060
GET A QUOTE.
*2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation.
GENERAL
Dry Weight kg 3050
Boiler Dimensions mm 2180 (H) x 1225 (W) x 3080 (D)
Boiler Clearances mm Front: 3100 Left Side: 600 Right Side: 600 Rear: 1000
Seasonal Efficiency % 95.7
Min/Max Gas pressure (Nat Gas) mbar 17.5 - 20
BURNER
Fuel Natural Gas / LPG
Furnace Pressure mbar 7.4
Furnace Volume dm³ 1249.0
Min Burner Length mm 350
Burner Diameter mm 222
Boiler Output (80/60) kW 1412.3
Boiler Output (50/30) kW 1551.5
Boiler Input kW 1251
HYDRAULICS
Pressure drop ∆T 10°C mbar 150.1
Pressure drop ∆T 20°C mbar 36.3
Nominal Flow Rate ∆T 10°C l/m 2074.3
Nominal Flow Rate ∆T 20°C l/m 1034.8
Min Flow Rate l/s 4.58
Min Working Temperature °C 30
Max Working Temperature °C 90
Min Working Pressure bar 1
Max Working Pressure bar 6
Max Static Head Of Water metres 60
Condensate Connection inches 1.25
High Limit Set Point °C 110
Flow Size G2”
Water Content litres 1900
Return High Temperature DN 100
Return Low Temperature DN 150
FLOOR STANDING
** Dependent on return temperature
211191