DESCRIPTION
Thompson Developments Garstang Road, Poulton-Le-FyldeTRANSCRIPT
Working with
In Respect of
Un-Adopted Thompson Developments Pump Stations
Garstang Road, Poulton-Le-Fylde
Pro-Active Pump-station Adoption Scheme
Pursuant To The Provisions Of
Section 104 Of The Water Industry Act 1999
Statutory Water Company Services Ltd
t: 0844 8797131
www.wcservices.co.uk
Reference: THP01&02
Issued: August 2011
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 1
CONTENTS
Preface Page 2
Location Details Page 3
Executive Summary Page 4
Schedule of Condition Page 7
Condition Report Page 8
Appendix Page 16
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 2
PREFACE
Client Name: United Utilities
Client Address: Wastewater Adoptions
Cabin C
Warrington North Wastewater Treatment Works
Gatewarth Industrial Estate
Liverpool Road
Sankey Bridges
Warrington
WA5 1DS
Report Prepared By: Liam Howarth
Date of Inspection: 11th August 2011
Project Address: ‘Little Poulton Gardens’
Off Garstang Road East
Poulton-Le-Fylde
Lancashire
FY6
Reviewed By: Liam Melly
Review Date: 30th August 2011
Project Information
The currently unadopted foul and surface water pump stations at the
abovementioned development were constructed circa 2008/2009. Two
Emod pumps can be located in both wet wells working on a ‘Duty and
Standby’ operation. These pump stations are currently serving 199
properties including 47 houses and 152 apartment.
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 3
LOCATION DETAILS
1.0 Project Address
‘Little Poulton Gardens’
Off Garstang Road East
Poulton-Le-Fylde
Lancashire
FY6
2.0 Local Information
The development is located off Garstang Road East (A586) which
is busy commuter highway to Blackpool and the surrounding
areas.
Opposite the site entrance is the Poulton Industrial Estate
which contains an extensive number of businesses which all use
the local highways
3.0 A train station is within one mile of the scheme and is part
of the major network in and out of Blackpool.
4.0 Extracts of Construction Drawings
5.0 Extract from Ordnance Survey
Arial View Site Entrance
6.0 Other Information
Grid Reference: SD 35780 39261
Easting: 335780m / Northing: 439261m
Latitude: 53.845601 / Longitude: -2.9775770
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 4
EXECUTIVE SUMMARY
1.0 Manholes
United Utilities have confirmed that all manholes on the
scheme are satisfactory for adoption with no further works
required.
2.0 Drainage Lengths
United Utilities have confirmed that all adoptable drainage
lengths on the scheme are satisfactory for adoption with no
further works required.
3.0 Compound
United Utilities confirmed that the compound area surrounding
the pump station is not secure and have therefore requested
that the existing fencing is taken down and replaced with a
new, more secure galvanized palisade fence in order to prevent
unauthorised access. It was also noted that no provision has
been made for vehicular access to the Pump Station Compound. A
drop crossing will require constructing to the footpath in
order to allow sufficient access to the compound. A road
opening notice will be required in order to complete these
works in compliance with Lancashire County Council
regulations.
The lack of maintenance within the compound was also apparent
which will require the overgrown vegetation to be cut back in
order for the compound to be deemed of an acceptable standard
for adoption.
4.0 Kiosk
There are a minor amount of works required to the Pump Station
Kiosk. These include the replacement of the lock to the Kiosk
door.
5.0 Surface Water Wet Well
There are a moderate amount of works required to bring the
surface water Wet Well up to an adoptable standard. A number
of the items required to the Wet Well are due to incomplete
works including; the required installation of a safety grid
system, install locking bars over the Wet Well cover in order
to prevent unauthorised access, earth bonding required to the
ladder and the application of pump name plates to the pumps.
Other remedials required to the Wet Well are due to
deterioration. These include; pump lifting chains corroding
which will need to be replaced, bearing seals and rings of the
pumps require replaced, the inlet penstock requires servicing
and the impellers to Pump №1 and Pump №2 also need replacing.
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 5
6.0 Surface Water Valve Chamber
Although the Valve Chamber is currently unsatisfactory for
adoption purposes, there were no major remedials that were
identified during the inspection. The remedials required to
the surface water Valve Chamber include; the installation of
locking bars over the Valve Chamber cover in order to prevent
unauthorised access, installation of thrust blocks and the
replacement of gate valve №1.
7.0 Foul Water Wet Well
There were only a small number of defects identified to the
Foul Water Wet Well which require remedy works which entail
the following; installation of locking bars over the Wet Well
cover to prevent unauthorised access, testing of the Davit
Socket and arm ensuring it functions correctly, application of
pump name plates to the pumps, earth bonding to the metal
surfaces within the Wet Well and the servicing of the inlet
penstock.
8.0 Foul Water Valve Chamber
As with the Surface Water Valve Chamber, the Foul Water Valve
Chamber although currently unsatisfactory for adoption
purposes, there were no major remedials that were identified
during the inspection. The main item to be completed is the
replacement of the non-return valve ensuring it is functioning
satisfactorily. Apart from the replacement of the non-return
valve, the only other remedy works required to the Foul Water
Valve Chamber include; installation of locking bars over the
Foul Water Valve Chamber cover to prevent unauthorised access,
application of earth bonding to the metal surfaces and also
cleansing of the Valve Chamber via jetting and manual methods
ensuring it is left tidy for re-inspection.
9.0 Documentation
A comprehensive documentation pack detailing design criteria,
operations, maintenance guides and testing certificates will
need to be compiled and submitted prior to the Pump Station
hand over. Specific items to be included are:
• 2 Sets of Operations & Maintenance Packs, including; User
guides, electrical schematics, operation philosophy and
parts list
• 6 copies of a 1:500 plan of the pump station indicating
land that is to be transferred
• Completion of the asset register form.
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 6
10.0 Legal Issues
A land registry check will need to be completed prior to
adoption of the Pump Station in order to indicate the areas
and boundaries of the land that is subject to be transferred.
The ownership of this area along with the pump station itself
will need to be transferred to United Utilities to allow
subsequent handover prior to adoption.
11.0 Health and Safety
With the specialist nature of the works it will be necessary
to satisfy all health and safety requirements. All persons
undertaking the works within the wet well and valve chamber
must be approved, confined space qualified and have all the
necessary health and safety equipment such as gas detector,
harness etc to ensure safe entry and working conditions are
satisfied.
12.0 Potential Hindrances
Aside from the issues detailed within the report there are no
known issues that will prevent the adoption of the sewers on
the scheme.
13.0 Summary
There are a moderate amount of works required to the pump
station and compound in order to meet the requirements of
United Utilities. A number if items identified relate to the
security of the pump station including the replacement of the
perimeter fencing of the compound and the requirement to
install locking bars over the Wet Wells and Valve Chambers.
The completion of these items ensures no unauthorised access
can be achieved and ultimately ensures the safety of the
public.
Although there are a moderate amount of works required to the
pump station and surrounding compound, the works can be
carried out with relative ease following relevant resident
liaison and engineering supervision / organisation. Following
the completion of these works, as stated within our
recommendations, we foresee no major hindrances to prevent the
progress of adoption.
A re-inspection will be organised to follow these works to
ensure all items detailed within the report have been
completed to United Utilities specifications.
14.0 Works Valuation
The estimated cost to complete all the required works to bring
the pump stations to an adoptable standard is £25,014.00.
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 7
SCHEDULE OF CONDITION
1.0 Compound
1.1 Entrance
1.2 Boundary Fence
1.3 Surrounding Environment
2.0 Kiosk
2.1 Entrance
3.0 Surface Water Wet Well
3.1 Health and Safety
3.2 Lifting Equipment
3.3 Access
3.4 Pumps
3.5 Penstock
3.6 Dirt / Debris
4.0 Surface Water Valve Chamber
4.1 Health and Safety
4.2 Thrust Blocks
4.3 Gate Valves
4.4 Dirt / Debris
5.0 Foul Water Wet Well
5.1 Health and Safety
5.2 Lifting Equipment
5.3 Access
5.4 Pumps
5.5 Penstock
5.6 Dirt / Debris
6.0 Foul Water Valve Chamber
6.1 Health and Safety
6.2 Non-Return Valves
6.3 Dirt / Debris
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 8
Condition Report
1.0 Compound
1.1 Defect
No provision has been made for vehicular access to the
Pump Station Compound
1.2 Defect
A. No secure fencing to the perimeter of the Pump Station
Compound
B. Insufficient access into Pump Station Compound due to
bolted access fence
1.3 Defect
Overgrown shrubbery evident within Pump Station Compound
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 9
1.3 Defect
Trip hazards evident within the compound due to low spots
surrounding Wet Well and Valve Chamber cover slabs
2.0 Kiosk
2.1 Defect
No key available for Yale lock
3.0 Surface Water Wet Well
3.1 Defect
No safety grid system fitted within Wet Well
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 10
3.1 Defect
Locking bars have not been installed over the Wet Well to
prevent unauthorised access
3.2 Defect
Pump lifting chains on both pumps corroding
3.2 Defect
Davit Socket requires testing
3.3 Defect
Access ladder requires earth bonding
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 11
3.4 Defect
Pump №1 not sealed sufficiently consequently allowing
water into oil housing
3.4 Defect
No pump indication plates shown on the pumps
3.4 Defect
Impellers to Pump №1 and Pump №2 not functioning
satisfactorily
3.5 Defect
Inlet penstock requires servicing
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 12
3.6 Defect
Dirt / Debris OK
4.0 Surface Water Valve Chamber
4.1 Defect
Locking bars have not been installed over the Valve
Chamber to prevent unauthorised access
4.2 Defect
No thrust blocks constructed within Valve Chamber
4.3 Defect
Gate valve №1 not functioning satisfactorily
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 13
4.4 Defect
Dirt / Debris OK
5.0 Foul Water Wet Well
5.1 Defect
Locking bars have not been installed over the Wet Well
cover to prevent unauthorised access
5.1 Defect
Metal surfaces including ladder requires earth bonding
5.2 Defect
Davit Socket requires testing
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 14
5.3 Defect
Access OK
5.4 Defect
No pump indication plates shown on the pumps
5.5 Defect
Inlet penstock requires servicing
5.6 Defect
Dirt / Debris OK
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 15
6.0 Foul Water Valve Chamber
6.1 Defect
Locking bars have not been installed over the Valve
Chamber to prevent unauthorised access
6.1 Defect
Metal surfaces require earth bonding
6.2 Defect
Non-return valve not functioning satisfactorily
6.3 Defect
Build up of dirt and debris within Valve Chamber
Pro-Active Pump-station Adoption Scheme August 2011
Garstang Road, Poulton-Le-Fylde Page 16
APPENDIX
1.0 Surface Water Pump Station Inspection Sheets
1.1 Civils
1.1.1 General Health and Safety
1.1.2 Grounds
1.1.3 Kiosk
1.1.4 Valve Chamber
1.1.5 Wet Well
1.1.6 Additional Notes / Comments
1.1.7 Locks
1.2 Mechanical & Electrical
1.2.1 Wet Well
1.2.2 Valve Chamber
1.2.3 Kiosk
1.2.4 Panel
1.2.5 Pump Details
1.2.6 Summary of Defects
2.0 Foul Water Pump Station Inspection Sheets
2.1 Civils
2.1.1 General Health and Safety
2.1.2 Grounds
2.1.3 Kiosk
2.1.4 Valve chamber
2.1.5 Wet Well
2.1.6 Additional Notes / Comments
2.1.7 Locks
2.2 Mechanical & Electrical
2.2.1 Wet Well
2.2.2 Valve Chamber
2.2.3 Kiosk
2.2.4 Panel
2.2.5 Pup Details
2.2.6 Summary of Defects