Exhibit II Equipment Lists & Sample Service Sheet
Site 1 - CBJTC Post Headquarters:
Bldg. 2300 - 3 pages
Site 2 - CBJTC CSMS Buildings:
Bldg. 4100-3 pages Bldg. 4104-3 pages Bldg. 4105-2 pages Bldg. 4106-1 pages Bldg. 4114-1 page
Sample Service Sheet - 2 pages Note: Equipment specific Service sheets for equipment and sites will be available at the mandatory site visit.
CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site 1
IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I
AIR HANDLERS
AHU-1 Central Station Air Handler
with VFD, 0-15 HP
Carrier 39MN06C0190 S0780UOS016
AHU-2 Central Station Air Handler
with VFD, 0-15 HP
Carrier 39MN06C0190 708UOS018
AHU-3 Central Station Air Handler
with VFD, 0-15 HP
Carrier 39MN06C0190 708UOS019
AHU-4 Central Station Air Handler Trane CCDB
AHU-S Central Station Air Handler
with VFD, 0-15 HP
Trane CCDB
AHU-6 Central Station Air Handler Trane CCDB
AHU-7 Central Station Air Handler Carrier 39MN06C0190 S078US021
AHU-8 Central Station Air Handler Carrier 39MN06C0190 S078US022
SERVICE FREqUENCY
Operationals
Filter Changes
Comprehensive
TIMES PER YR
4
6
1
SPLIT SYSTEM
SS-l Split System Heat Pump Trane
SS-2 Split System Heat Pump York
SS-3 Split System Heat Pump Goodman
SERVICE FREqUENCY TIMES PER YR
Operationals 4
Filter Changes 6
Comprehensives 1
Condenser Coil Cleaning 1
CBJTC August 12, 2011
1
CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site 1
I EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODEL ISERIAL NUMBER I PUMPS
P-1 Circulating Pump Bell & Gossett 1510 C057694-01A80
P-2 Condenser Water Pump Bell & Gossett 2BC
P-3 Hot Water Pump Bell & Gossett 11/4BC
SERVICE FREQUENCY TIMES PER YR
Operationals 4
Comprehensives 1
CHILLER
IAC-1 I Water Cooled Chiller I Carrier I 30HXCl06 I 0508Q08739 I
SERVICE FREQUENCY TIMES PER YR
Operationals 4
Comprehensives 1
Chiller Tube Brushing 1
MISC EQUIPMENT
CT-1 Cooling Tower with Strainer I Marley 4799-1000 I HWB-1 Hot Water Boiler I Burnham PF504 I 7571160
SERVICE FREQUENCY TIMES PER YEAR
Operationals 4
Comprehensives 1
CBJTC August 12, 2011
2
CBJTC Post HQ Building 2300
IEQUIPMENT # I EQUIPMENT TYPE I Exhibit II -Covered Equipment List Site 1 MANAFACTURE I MODEL I~SE-R-IA-l-N-U-M-B-E-R""I
CONTROLS
IDDC-l I Building Automation System I Johnson Controls I Metasys G-l I I
1 Network Application Engine (NAE-4s) level one controller
13 Field Equipment controllers level two controller
26 Variable Air Volume Modular Assembly
Variable Drive
15 I Variable Drive I I I I
SERVICE FREQUENCY TIMES PER YEAR
Operationals 4
Comprehensives 1
CBHC August 12, 2011
3
CBJTC - CSMS ADMIN BLDG 4100 Exhibit II - Coverd Equipment List Site 2
IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODel ISERIAL NUMBER I AIR HANDLERS
AHU-1 Air Handler Unit, Return York XTl-102X051-FAKA046A
AHU-2 Air Handler Unit, Return York XTl-084X075-FA1A046A
SERVICE REQUIRED TIMES PER YR
Operationals 4
Filter Changes 4
Evaporator Coil Cleaning 1 Comprehensive 1
SPLIT SYSTEM
155-1 Split System 0-15TI I I I I
SERVICE REQUIRED TIMES PERYR
Operationals 4
Filter Changes 4
Comprehensives 1 Condenser Coil Cleaning 1
PUMPS
P-1 Circulating Pump B+G 1510
P-2 Circulating Pump B+G 1510
SERVICE REQUIRED TIMES PERYR
Operationals 4
Comprehensives 1
CBJTC December 2, 2011
1
CBJTC - CSMS ADMIN BLDG 4100 Exhibit II - Coverd Equipment List Site 2
~ EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I CHILLER
IAC-1 I Air Cooled Chiller I York I YCA10060EC46X I I
HEATERS
SERVICE REQUIRED
Operationals
Comprehensives
Coil Cleaning
Oil Analysis
TIMES PERYR
4
1
1
1
HG-1 Heater, Gas Infrared Robert Gordon
HG-2 Heater, Gas Infrared Robert Gordon
HG-3 Heater, Gas Infrared Robert Gordon
SERVICE REQUIRED TIMES PER YEAR
Operationals 4
Comprehensives 1
CONTROLS
1 Building Automation System Metasys
C-1 VMA Controller (QTY 13) Johnson Control
C-2 DX-1900 Controller (QTY 1) Johnson Control
C-3 MIG Controller (OTY 1) Johnson Control
C-4 UNT Controller (OTY 1) Johnson Control
SERVICE REQUIRED Times PerYr
Comprehensive 1
Operationals 4
CBHC December 2, 2011
2
CBJTC - CSMS ADMIN BLDG 4100 Exhibit 1\ - Coverd Equipment List Site 2
r EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I EXHAUST FANS EF-1 Ceiling Mounted Exhaust Fan Greenheck 850-90-4
EF-2 Ceiling Mounted Exhaust Fan Greenheck 850-120-4
EF-3 Ceiling Mounted Exhaust Fan Greenheck 5BE-3H24-S
SERVICE REQUIRED TIMES PER YEAR
Operationals 2
VAVBOX
IVBX-1 VAV Box (OTY 7) TraneI I I I I
SERVICE REQUIRED TIMES PERYR
Operationals 4
Comprehensives 1
Filter Changes 6
CBJTC December 2, 2011
3
CBJTC - CSMS Allied Trades BLDG 4104 Exhibit" - Coverd Equipment List - Site 2
IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEl ISERIAL NUMBER I AIR HANDLERS
I IIAHU-1 I Air Handler Unit, Mixed Vari Volume 1 10-40HP I SERVICE REQUIRED TIMES PERYR
Operationals 4
Filter Changes 4
Evaporator Coil Cleaning 1
Comprehensive 1
AIR HANDLER
IAHU-2 IAir Handler Unit, Mixed Const Vol (QTY 5) I I 10HP 1 I
SERVICE REQUIRED TIMES PERYR
Operationals 4
Filter Changes 4
Comprehensives 1
SPLIT SYSTEM
ISS-1 I Split System (QTY 2) I 1 0-lST I 1
SERVICE REQUIRED TIMES PER YR
Operationals 4
Filter Changes 4
Condenser Coil Cleaning 1
Comprehensive 1
CBJTC December 2, 2011
1
CBJTC - CSMS Allied Trades BLDG 4104 Exhibit II - Coverd EauiDment List - Site 2
EQUIPMENT # EQUIPMENT TYPE MANAFACTURE I MODEL SERIAL NUMBER
AIR COMPRESSOR
IAC-1 Air Compressor, Commercial 1 Commercial I 5-20HPI I I
SERVICE REQUIRED TIMES PER YR Operationals 4
Comprehensives 1
AIR COMPRESSOR
IAC-1 Air Compressor, Industrial (QTY 3) Industrial 76-125 HPI I I I I SERVICE REQUIRED TIMES PER YR
Preventive Maintenance 1
Operationals 4
Comprehensives 1
HEATERS
IHG-1 Heater, Gas Infrared (QTY 11) Robert GordonI I I I I
SERVICE REQUIRED TIMES PER YEAR Operationals 4
Comprehensives 1
CONTROLS
IC-4 UNT Controller (QTY 1) Johnson Control ASC1 I I I I
SERVICE REQUIRED Times PerYr Comprehensive 1
Operationals 4
CSHC December 2, 2011
2
IEQUIPMENT # I EQUIPMENT TYPE
CBJTC - CSMS Allied Trades BLDG 4104 Exhibit II - Coverd Equipment List - Site 2
I MANAFACTURE I MODEL ISERIAL NUMBER I EXHAUST FANS
IEF-l I Wall Mounted Exhaust Fan (OTY 2) I I O-SHP I I
SERVICE REQUIRED TIMES PER YEAR
Operationals 2
EXHAUST FANS
IVAF-l Vane Axial Fan 3FT DiaI I I I I SERVICE REQUIRED Times Per Yr
Comprehensive 1
Operationals 4
VARIABLE DRIVE
IVD-l I Variable Spd Drive (Mech Lg) I Mech-Lg I I I
SERVICE REQUIRED Times PerYr
Comprehensive 1 Operationals 4
CBJTC December 2, 2011
3
CBJTC - CSMS Electronics BLDG 4105 Exhibit II - Coverd Equipment List Site 2
IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I
AIR HANDLERS AHU-1 Air Handler Unit Mixed, Const Volume I 10HP
AHU-2 Air Handler Unit, Mixed Vari Volume I 10-40HP
SERVICE REQUIRED TIMES PER YR
Operationals 4
Filter Changes 4
Evaporator Coil Cleaning 1 Comprehensive 1
AIR HANDLER
IAHU-3 IAir Handler Unit, 100% OSA Const volumel I 10HP I I SERVICE REQUIRED TIMES PER YR
Operationals 4
Filter Changes 4
Comprehensives 1
SPLIT SYSTEM
155-1 Split System 0-lSTI I I I I
SERVICE REQUIRED TIMES PER YR
Operationals 4 Filter Changes 4
Comprehensives 1
CBJTC December 2, 2011
1
I EQUIPMENT # I EQUIPMENT TYPE
CBJTC - CSMS Electronics BLDG 4105 Exhibit II - Coverd Equipment List Site 2
I MANAFACTURE I MODEL ISERIAL NUMBER I HEATERS
HG-1
HG-2 I I
Heater, Gas Infrared
Heater, Gas Infrared I I
Robert Gordon
Robert Gordon
SERVICE REQUIRED TIMES PER YEAR
Operationals 4
Comprehensives 1
CONTROLS
IC-4 I UNT Controller (QTY 1) I Johnson Control I ASC 1 1
SERVICE REQUIRED Times PerYr
Comprehensive 1
Operationals 4
EXHAUST FANS
EF-1 Wall Mounted Exhaust Fan I O-SHP
VAF-1 Vane Axial Fan I SFT Dia
SERVICE REQUIRED TIMES PER YEAR
Operationals 2
VARIABLE DRIVE
I I IIVD-1 1 Variable Spd Drive (Mech Sm) Mech-Sm 1
SERVICE REQUIRED Times PerYr
Comprehensive 1
Operationals 4
CBJTC December 2, 2011
2
IEQUIPMENT # I EQUIPMENT TYPE
CBJTC CSMS Auto Service BLDG 4106 Exhibit II - Coverd Equipment List Site 2
I MANAFACTURE I MODEl ISERIAl NUMBER I AIR COMPRESSOR
IAC-1 I Air Compressor, Commercial (QTY 2) I Commercial I S-20HP I I
SERVICE REQUIRED TIMES PER YEAR
Operationals 4 Comprehensives 1
HEATERS
IHG-1 Heater, Gas Infrared (QTY 2) 1 Robert Gordon I 1 1I
SERVICE REQUIRED TIMES PER YEAR
Operationals 4 Comprehensives 1
CONTROLS
IC-1 UNT Controller Johnson Control ASC II I I I
SERVICE REQUIRED Times PerYr
Comprehensive 1 Operationals 4
SPLIT SYSTEM
155-1 1 Split System (QTY 2) I I 0-lST I I
SERVICE REQUIRED TIMES PER YR
Operationals 4
Filter Changes 4
Condenser Coil Cleaning 1 Comprehensive 1
CBJTC December 2, 2011
1
CBJTC - CSMS Storage BLDG 4114 Exhibit II -Coverd Equipment List Site 2
IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAl NUMBER I EXHAUST FANS
EF-l
EF-2
Wall Mounted Exhaust Fan
Wall Mounted Exhaust Fan
SERVICE REQUIRED TIMES PERYR
Operationals 4
Comprehensive 1
HEATER
IUH-l Unit Heater I I I I I
SERVICE REQUIRED TIMES PER YR
Operationals 4
Condenser Coil Cleaning 1
CBJTC December 2,2011
1
0
Sample Service Sheet
> >J::. ..... l0
t: OJ> 0 -elo ro~ ro
I :JSample -Type of Equipment OJ c:e>Comprehensives
Contact customer representative for performance issues X Check starter and contactor X Check and tighten electrical connections X Inspect pilot and safeties (as applicable) X Check flame quality X Check coil conditions X Check filter condition X Check and clean condensate pan and drain If accessible X Check safety control set points X Check damper operation and lubricate as required X Change belt(s) X LnecK vaIVe{S} }\
Check and lubricate fan and motor bearings X Check for proper fan rotation X Check condition of blower assembly X Check for unusual noises, vibration and wear Report recommendations X Check overall condition of unit X Clean area around equipment X Complete any required maintenance checklists, report observations to
Xappropriate customer representative
Operationals Complete any required maintenance checklists, report observations to
appropriate customer representative X Clean area around equipment X
Check overall condition of unit X
Check for unusual noises, vibration and wear Report recommendations X Check fan operation X Visually Inspect damper(s) X Check filter condition X
1
Sample Service Sheet
>""C Q)
-+oJ
>..c -+oJ c
> 0 ""C
~ L
ro ro Sample -Type of Equipment Q) I ::J
> co (j
Operationals continued
Check with appropriate customer representative for operational deficiencies X Check belt(s) (if applicable) X Check coil conditions X Secure and check all electrical connectors X Inspect fan wheel for free movement, excessive play and debris X
Confirm that all mounting hardware is tight X Clean and Paint corroded areas as necessary X Check condensate pan and drain If accessible X
Filters, Misc.
Dispose of dirty filter appropriately X Turn equipment on X Install new filters X Remove dirty filters X Turn equipment off X Lubricate & inspect fan bearings. X Replace air filters per agreement X
Check with appropriate customer representative for operational deficiencies X IComplete any required maintenance checklists, report observations to
appropriate customer representative X
2