expansion joints
DESCRIPTION
The presentation will include technical terminologies along with sizing of metallic and non-metallic expansion joints which are used in Steel/Cement/Minerals/Power industries.TRANSCRIPT
![Page 1: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/1.jpg)
Expansion Jointby
Nivedit Mathur & Manik DeshpandeNISH-IN MLD-IN
![Page 2: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/2.jpg)
2
This presentation consists of:- Introduction. Definition and Application. Working Principle. Metallic versus Non-Metallic types. General considerations for calculating expansion values. Case wise methodology:- I – For Straight Duct. II – For Inclined Duct. III – For Pre-heater downcomer duct. IV – For Duct with connecting equipments. V – For Duct subjected to different temperatures. VI – For Expansion Joint located nearer to process damper. VII – For Duct subjected to transverse/angular expansion. Exercises.
![Page 3: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/3.jpg)
3
Introduction:-
The reasons for organizing this presentation are:-
To minimize expansion joint problem/failure at project sites.
To minimize PL5 dependencies on Plant Utilities.
To establish a common platform interms of understanding expansion joint terminology, calculation, behavior and documentation.
![Page 4: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/4.jpg)
4
Definition and Application:-
Expansion Joint is an flexible connector designed to perform the following four major task:-
To allow expansion and contraction of the duct due to temperature changes.
To provide isolation of a component to minimize the effects of vibration and noise.
To allow movement of component during process operation.
To aid in installation or removal of large components and erection tolerances.
![Page 5: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/5.jpg)
5
Definition and Application:
Axial Elongation – Dimensional lengthening of
the expansion joint along its longitudinal axis.
Axial Compression – Dimensional shortening of
the expansion joint along its longitudinal axis.
Lateral Movement – Relative displacement of the two ends
of the expansion joint perpendicular to
its longitudinal axis.
Angular Movement – Displacement of the longitudinal axis of
the expansion joint from its initial straight
line position into a circular arc.
![Page 6: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/6.jpg)
6
Working Principle:-
Non Metallic Type – Works on the basis of fabric as flexible element formed into
one or maximum two convolution.
Metallic Type – Works on the basis of thin metallic sheets as flexible element
formed into multiple convolutions.
![Page 7: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/7.jpg)
7
Metallic versus Non-Metallic Type:
Temperature
Standard rubber joints have an upper range to 230-deg F.
Standard metal joints are designed up to 420-deg F to 1800-deg F. Movements
Rubber joints absorbs far greater lateral movements when compared to metal joints
Similar face to face dimensions. Spring Rates – Defined as the total force required to move an expansion joint
by one inch in any direction.
Rubber Joints – Low spring rate.
Metal Joints – High spring rate. Gas Tightness at all temperature
Rubber Joints – Lower
Metal Joints - Higher
![Page 8: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/8.jpg)
8
Basic Consideration:-
Temperature for calculation (T) = design - minimum ambient temperature(If not insulated) and Temperature =design (IF insulated).
Thermal coefficient (a) = 12x10^-6. Length(L):
Length can be calculated from the 1st fixed support to expansion
joint center and Expansion joint center to 2nd Fixed Support. No need to consider any margin for values of expansion joint as it is calculated for
design temperature.
![Page 9: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/9.jpg)
9
Basic Consideration:-
If movements acts in same direction then the movements value should be subtracted and vice versa...
For those expansion joints which comes with connecting equipment the movements due to corresponding Connecting equipment also has to be considered.
1. For Cyclone, Temperature should be skin temperature
2. For ESP and other Connecting equipment, movements will be specified in the OL drawings.
3. For mill and cooler as per respective department there will be no movements. For tall elevators and chain conveyors expansion values given in the respective OL/ Supplier drgs
to be considered
Formula:-Increase in length = aTL
![Page 10: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/10.jpg)
10
Case wise Methodology: I – For Straight Duct.
![Page 11: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/11.jpg)
11
II – For Inclined Duct.
![Page 12: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/12.jpg)
12
III – For Pre-heater downcomer duct.
Two different values of temperature must be
considered for calculation
For Cyclone Temperature should be skin temperature
Total axial movement is 35.145+12.48=47.625~50mm
III – For Pre-heater downcomer duct.
![Page 13: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/13.jpg)
13
IV – For Duct with connecting equipments.
Movement due to connecting equipment must be taken in to
consideration.
Resultant movement
![Page 14: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/14.jpg)
14
V – For Duct subjected to different temperatures.
Two different temperature condition on the same duct.
Two different temperature condition on the same duct.
![Page 15: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/15.jpg)
15
VI – For Expansion Joint located nearer to process damper.
During shut off condition the movements due to duct 85-10 will alone exist and movements due to
duct 85-3 will not act So maximum lateral movements is considered and axial movements due to both duct considering working condition..
![Page 16: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/16.jpg)
16
VII – For Duct subjected to transverse expansion.
As Axial movement for this expansion joint act in the same direction
the relative value Should be considered ..
As both the lateral values act in two different axis the resultant is taken
(√13.152+21.482)
Two different temperature condition
on the same duct.
Two different temperature condition
on the same duct.
![Page 17: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/17.jpg)
17
VIII – Special Case.
In cases like this where the slide support is placed you have to
check the moment acting on the fixed support.
Resultant movement
![Page 18: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/18.jpg)
18
Exercise
![Page 19: Expansion Joints](https://reader033.vdocument.in/reader033/viewer/2022052118/558b4b33d8b42a3b2a8b462b/html5/thumbnails/19.jpg)
19
Thank you.