Protons - Superior Dose Distribution
The Bragg Peak is representative of a delivery of a full, localized, and uniform dose of energy in the target R
elat
ive
Dos
e 3
2
1
0 10 20 30Depth in Tissue (cm)
4
60
Experience, Expertise and a Commitment to Excellence™
System Components
The Synchrotron Accelerator
The Beam Transport System
The Stationary Beam Gantries (Isocentric
Gantries) Patient Alignment and
Digital Imaging Systems Facility Control System
Experience, Expertise and a Commitment to Excellence™
Facility LayoutThe Loma Linda University Medical Center Proton Treatment CenterStationary Beam:
Has two branches: •Eye Tumors •Head and Neck Tumors
The Injector:Protons are stripped out of the nucleus of hydrogen atoms and sent to the accelerator.
Synchrotron: (Accelerator)A ring of magnets, 20 ft. in diameter, through which protons circulate in a vacuum tube.
Beam Transport System:Carries the beam from the accelerator to one of four treatment rooms. This system consists of several bending and focusing magnets which guide the beam around corners and focus it to the desired location.
The Gantries:Resembling giant ferris wheels can rotate around the patient and direct the proton beam to a precise point. Each gantry weights about 90 tons and stands 3 stories tall. It supports the bending and focusing magnets to direct the beam.
Steel-reinforced concrete walls are up to 15 feet thick.
Experience, Expertise and a Commitment to Excellence™
Proton Accelerator Control System
Conforma 3000 Integrated Solution Treatment Control
System (TCS) Accelerator Control
System (ACS) Treatment Workstation Integrated and
Automated
“The Brain”Software & Electronics for Treatment Precision
AccelerateDeliverControl
Experience, Expertise and a Commitment to Excellence™
Accelerator Control - Advantages
Automatic Beam Centering in Treatment Nozzle Key to Active Beam Scanning
Rapid Beam Line Switching <10 sec.
Accurate, Reproducible Beam Energy Within 0.1 MeV
Patented Safety Systems Ensure Beam is Delivered at the Right Place & Time
Experience, Expertise and a Commitment to Excellence™
Gantry Treatment Room
Integrated and automated Rotates >360o
Treatment from multiple “portals” or angles
Isocenter is contained within a sphere to 1.0 mm in radius
Automated set up Designed for functionality
Experience, Expertise and a Commitment to Excellence™
Conforma 3000 Passive Scattering Beam Delivery System
Compensator (Bolus) and
Block (Aperture)
Range Modulation
WheelSecond
ScattererFirst
Scatterer
Dose andFlatness
Monitor(s)
X-rayTube Profile
Monitor
MovableSnout
(cones)
Beam
Experience, Expertise and a Commitment to Excellence™
Conforma 3000 Active Beam SystemIntensity Modulated Proton Therapy
OptionalCompensator (Bolus) and
Block (Aperture)
MovableSnout
(cones)
Redundant Dose
Detectors
Radiographic Imaging
Panels (2)
Scanning Magnets
Beam
IMPT or Active Beam Scanning (ABS)
Supports Compensator-less treatments
Variable energy controls penetration depth
Capable of continuous (raster scanning) &
discrete point based (“Spot” scanning)
Experience, Expertise and a Commitment to Excellence™
Intensity Modulated Proton Therapy
Ability to Treat Complex Volumes & Multiple Target Areas
“Spot Scanning” Technique Beam scans from the
top down Radiation deposited
from side to side
Experience, Expertise and a Commitment to Excellence™
Modular Design (4 gantry, 2 Stationary)
Experience, Expertise and a Commitment to Excellence™
Treatment Planning Software
Experience, Expertise and a Commitment to Excellence™
Contact Information
Jon Slater,
President & CEO
909.799.8333
Daryl Anderson
Chief Financial Officer
909.799.8342
David Lesyna
VP Engineering
909.799.8312
Mike Martin
VP of Sales
513.518.8037
Ken Rice
Director of Computer Science
909.799.8318
www.optivus.com