experimental and numerical energy performance analysis of...

34
Experimental and Numerical Energy Performance Analysis of PCM-Enhanced Building Envelope Products and Systems Jan Kosny, Nitin Shukla, and Ali Fallahi, Fraunhofer CSE Elisabeth Kossecka, Polish Academy of Sciences Contacts: Bryan Urban (Presenter) Dr. Jan Kosny (PI) [email protected] [email protected] © Fraunhofer USA [email protected] [email protected] CESBP 2013 Tuesday, Sept. 10, 2013 Vienna, Austria

Upload: others

Post on 20-Jan-2020

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Experimental and Numerical Energy Performance Analysis of PCM -Enhanced Building Envelope Products and SystemsJan Kosny, Nitin Shukla, and Ali Fallahi, Fraunhofer CSE

Elisabeth Kossecka, Polish Academy of Sciences

Contacts:

Bryan Urban (Presenter) Dr. Jan Kosny (PI)

[email protected] [email protected]

© Fraunhofer USA

[email protected] [email protected]

CESBP 2013

Tuesday, Sept. 10, 2013

Vienna, Austria

Page 2: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Agenda

� Introduction: A need for proper

performance data for PCMs used in

building applications – Major

Motivation

� PCM Application Tactics

� Laboratory Testing of PCM Thermal

First successful application of PCMs in buildings

© Fraunhofer USA

� Laboratory Testing of PCM Thermal

Characteristics

� Challenges with Computer Simulations

� Whole building Energy Analysis of PCM

Attic Insulation

� Conclusions

Page 3: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Major Motivation:

Performance Problems of

Conventional Insulation

© Fraunhofer USA

Conventional Insulation

Page 4: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Insulation Effectiveness Drops Quickly with Initial Assembly R-Value

Energy Savings: GJ/year

10

12

14

16

18

20

X

R-4

© Fraunhofer USA

0

2

4

6

8Atlanta

Bakersfield

Chicago

Denver

Houston

Knoxville

Miami

Minneapolis

Phoenix

Seattle

Washington DC

X � starting attic R-Value

20x difference !

Page 5: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

PCM Application Tactics:

Different PCM Configurations

© Fraunhofer USA

Page 6: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

European Approach – PCM Impregnated Gypsum Board

� PCM Charged by:

� Interior temperature swings

� Solar gains through glazing

� PCM Discharged by:

Distribution of Heating and Cooling Loads in Old PCM Applications

Exterior Finish

Exterior

Peak Loads Energy Transferred

Back to the

Environment

© Fraunhofer USA

� PCM Discharged by:

� Building HVAC system

Energy Discharged Later

by HVAC System

Cavity

Insulation

PCMPCM--Gypsum BoardGypsum Board

Interior

Energy Transferred into the Building Solar Gains

Energy stored

by PCM

Page 7: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

30

45[J/g]

Freezing

Problem with PCM Gypsum Board in Air Conditioned Buildings

Thermostat temperature control ± 2°F

[J/g-K] Enthalpy of Common Organic PCM

© Fraunhofer USA

-45

-30

-15

0

15

16 17 18 19 20 21 22 23 24 25 26 [°C]

Melting

Page 8: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

New Approach for PCM Installations in the U.S.

� PCM Charged and Discharged by:

� Fluctuations in exterior

temperature

� Solar radiation

Peak Hour Energy Transferred

Back to the Environment

Exterior Finish

Exterior

Peak Loads

Distribution of Heating and Cooling Loads in PCM-Enhanced Envelopes

© Fraunhofer USA

� PCM materials must be able to

fully charge and discharge during

24-hour dynamic cycle. Thermally Active Core

LOW HEAT TRANSFER

ZONE

Gypsum Board

Low Delta T

Min. Heat Transfer

Interior

Thermal insulation

Energy stored

by PCM

Page 9: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Laboratory Testing of PCM:

Thermal Characteristics

© Fraunhofer USA

Page 10: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Numerous Dynamic Test Methods are Used Today in Analysis of

Complex PCMs and PCM-enhanced Products

� DSC – only for uniform PCMs

� T-history method

� Dynamic Heat Flow Apparatus

� Symmetrical Process

� Non-symmetrical Process

© Fraunhofer USA

� Non-symmetrical Process

� Dynamic Guarded Hot Plate Method (speculation so far)

� Dynamic Hot Box Method

Page 11: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

DSC Method is Most Commonly Used but Has Limitations

© Fraunhofer USA

Page 12: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Large Selection of Non-Uniform PCMs Cannot be Tested by

Differential Scanning Calorimeter (DSC)

© Fraunhofer USA

PCM BlendPCM Blend

Page 13: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Major Thermal Analysis Problem for PCM Systems:

DSC data generated for pure (uniform) PCMs is often

used in analysis of complex PCM products or PCM

© Fraunhofer USA

used in analysis of complex PCM products or PCM

blends.

Page 14: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Need for Development of Enthalpy Charts for PCM-Enhanced

Materials and Systems

� Initial DSC testing results for pure PCMs or PCM microcapsules can be misleading

� Additives to PCM-blends make a difference: Fire retardants, Adhesives, Non-functional PCM pellets

10

12 DSC

80%

© Fraunhofer USA

0

2

4

6

8

10

18 20 22 24 26 28

Temp [deg C]

J/g-K

67%

Page 15: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Basic Heat Transfer Equations

The one-dimensional heat transport equation for such a case is as follows:

( ) Th

t x x

∂ ∂ρ λ∂ ∂ ∂ = ∂

ρ = densityλ = thermal conductivityT = temperatureh = enthalpy per unit mass

( ) ( ),,

T x tq x t

∂= −

Heat flux q is given by:

© Fraunhofer USA

( )eff

hc T

T

∂=∂

ceff = effective heat capacity Effective heat capacity is given by:

( )1eff ins effPCMc c cα α= − + α = percent of PCM

cins = heat capacity of pure insulation

ceffPCM = effective heat capacity of PCM

For a blend of insulation and PCM, effective heat capacity may be expressed as:

Page 16: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

DSC Output for Bio-Based PCM. Melting and Freezing Cycles

Show sub-cooling of 5°C

0.00

2000.00

4000.00

6000.00

8000.00

10000.00

DSC

uW

ou

tpu

t

DSC uW - 0.3C/min

Bio-PCM - 29degC

© Fraunhofer USA

-10000.00

-8000.00

-6000.00

-4000.00

-2000.00

17.0

19.0

21.0

23.0

25.0

27.0

29.0

31.0

33.0

35.0

37.0

DSC

uW

ou

tpu

t

Temperature [oC]

Two different enthalpy change profiles

for melting and freezing processes

Two different temperature peaks

Page 17: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Volumetric Heat Capacity for Cellulose-PCM Insulation Sample

using Bio-Based Micro-encapsulated PCMs

1000

2000

Melting

kJ/m3K-

© Fraunhofer USA

0

1000

10 12 14 16 18 20 22 24 26 28 30 32 34

Temperature (°C)

Freezing

Page 18: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

DSC Rate of Temperature Change Affects Enthalpy Profiles

Due to lack of clear eng. guidelines or code regulations, incorrect DSC data is very often used in whole building computer simulations

DSC Melting DSC Freezing

Heating rate Heating rate

Lower temperature limit

of PCM freezing range Upper temperature limit

of PCM melting range

© Fraunhofer USA

Temp. deg CTemp. deg C

J/KgK

J/KgK

Freezing threshold temp.

is a moving target

Page 19: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

A Standard Heat Flow Meter Apparatus (HFMA) Can Be Modified

To Perform Dynamic Testing of PCM-enhanced Products

5.0E+06

6.0E+06

7.0E+06

Vo

lum

etric

H P

rofil

e, J

/(m

3 )

Volumetric H (A)

Volumetric H (B)

Normally the HFMAs are used to measure the apparent thermal conductivity of materials as specified in ASTM C518.

© Fraunhofer USA

0.0E+00

1.0E+06

2.0E+06

3.0E+06

4.0E+06

4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

Vo

lum

etric

H P

rofil

e, J

/(m

Temperature, C

Volumetric H (B)

Volumetric H (C)

Page 20: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

M-value – New Energy Performance Label for

PCM-Enhanced Products

Expresses only the phase-change related enthalpy

© Fraunhofer USA

Expresses only the phase-change related enthalpy

change

Page 21: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

30

45[J/g]

Potential Misuse of Experimental Performance Data of

PCM-enhanced Products (likely for marketing purposes)

For what temperature range should PCM enthalpy be calculated if cp-related

effects are included together with phase transition–related effects?

This one?

[J/g-K] Enthalpy of commonly-used organic PCM

© Fraunhofer USA

-45

-30

-15

0

15

16 17 18 19 20 21 22 23 24 25 26 [°C]

Or, this one ???

Page 22: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Proposed Energy Performance Label for PCMs

M-value �TU

MT[J/g]

© Fraunhofer USA

M-value MTL

[J/g]

TU – upper temperature limit of the phase transition

TL – lower temperature limit of the phase transition

Page 23: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Practical Determination of M-value

1.4E+06

1.6E+06

1.8E+06

2.0E+06

2.2E+06

2.4E+06

2.6E+06

Vol

umet

ric s

peci

fic h

eat,

J/(m

^3 K

)

Volumetric Heat Capacity A

Volumetric Heat Capacity B

Volumetric Heat Capacity C

Subtract cp

related change

for melted PCM

Subtract cp

related change

for frozen PCM

© Fraunhofer USA

0.0E+00

2.0E+05

4.0E+05

6.0E+05

8.0E+05

1.0E+06

1.2E+06

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

Vol

umet

ric s

peci

fic h

eat,

J/(m

^3 K

)

Temperature, C

cp

related change for frozen PCM

Phase transition range>5% enthalpy change

per temperature step

cp

related change for melted PCM

Page 24: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Computer Simulation Challenges

Most whole building simulation tools

use one simplified enthalpy curve

© Fraunhofer USA

use one simplified enthalpy curve

(usually for melting)

Page 25: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

PCM Subcooling Effect is Not Properly Represented

Two independent enthalpy curves and upper and lower temperature limits generated by DSC tests for PCM-enhanced materials or composites still cannot be used today in whole building energy simulations (organic PCM data shown).

4,000

6,000

8,000

10,000DSC uW

27.2 oC (81.0 oF) 24.0 oC (75.2 oF)

© Fraunhofer USA

-10,000

-8,000

-6,000

-4,000

-2,000

0

2,000

4,000

10 15 20 25 30 35 40

24.0 oC (75.2 oF)

31.8 oC (89.2 oF)

oC

25.7 oC (78.3 oF)

Page 26: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Computer Simulation Challenges

Most whole building simulation tools

do not properly represent PCM

© Fraunhofer USA

do not properly represent PCM

thermal characteristics

Page 27: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Complex Arrays of PCM Containers Are Difficult To Test in

Conventional Equipment, Even More Difficult Numerical Analysis

Measure area needs to contain representative

geometry of the measured array of PCM containers

Example estimation of the measure area for arrays of PCM pouches

© Fraunhofer USA

Measure AreaMeasure Area

Page 28: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Computer Simulation Challenges

Complex 3D geometries for packaged

PCM products are not properly

© Fraunhofer USA

PCM products are not properly

represented by 1D algorithms used in

whole building simulation tools.

Page 29: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Whole building Energy Analysis of PCM Attic Insulations

Single Story Residential Building Modeled Using ESP-r

© Fraunhofer USA

Page 30: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Four Simulation Configurations

As a case study to demonstrate a practical

application of the ESP-r PCM model

SPMCMP56, we modeled a residential

single-story house in a hot climate with

PCM-enhanced cellulose ceilings.

Four Attic Assemblies:

PCM PCM

30cm

© Fraunhofer USA

Two zones:

conditioned space and

unconditioned attic PCMPCM

30cm

Page 31: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Underside Surface Temperature of Ceiling for Different PCM

Configurations

© Fraunhofer USA

Page 32: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Annual Cooling Load Simulation Results

Savings Are Relative to the Non-PCM Ceiling Case

© Fraunhofer USA

Page 33: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Conclusions

� During the last several decades, simple PCM applications like PCM-gypsum boards have dominated the

thermal storage market for building envelope applications. Today the focus has slowly begun to shift to

more complex PCM applications (i.e. PCM blends with insulations, PCM containers, etc.).

� A new dynamic testing procedure utilizing symmetrical step changes of temperature, and whole building

energy simulations using ESP-r model were utilized in this paper.

� A conventional heat-flow meter apparatus was used to obtain transient heat flux data for fiber insulation

© Fraunhofer USA

� A conventional heat-flow meter apparatus was used to obtain transient heat flux data for fiber insulation

material containing microencapsulated PCM.

� The routinely used DSC method for dynamic thermal property measurement of a PCM is valid only for small

quantities of pure PCM and is not appropriate for large-scale PCM-enhanced building components

� In this work, we employed a novel method based on HFMA to measure dynamic thermal properties.

� In this PCM study, we used earlier validated ESP-r PCM model SPMCMP56, for the energy modeling and PCM

performance analysis.

� Simulation result showed PCM-enhanced cellulose yields a whole-building cooling load energy saving from

3.6% to 5.7% depending on the PCM configuration for the Phoenix, AZ climate. These savings correspond to

approximately a 38.0% to 47.5% reduction in the attic-generated cooling loads.

Page 34: Experimental and Numerical Energy Performance Analysis of ...info.tuwien.ac.at/cesbp/presentations/M-4.1/05... · Experimental and Numerical Energy Performance Analysis of PCM-Enhanced

Thank You!

© Fraunhofer USA

Author Contact: Jan Kosny

[email protected]

Ph: +1-865-607-6962

Presenter: Bryan Urban

[email protected]

Ph: +1-617-588-0618