Experion PKS R430.3 Software Change Notice EPDOC-X175-en-4303E February 2015 Release 430.3

Upload: josh334

Post on 29-Sep-2015

200 views

Category:

Documents


11 download

DESCRIPTION

Experion R430 Software Change Notice

TRANSCRIPT

  • Experion PKSR430.3 Software Change Notice

    EPDOC-X175-en-4303EFebruary 2015

    Release 430.3

  • Document Release Issue DateEPDOC-X175-en-4303E 430.3 0 February 2015

    DisclaimerThis document contains Honeywell proprietary information. Information contained herein is to be used solelyfor the purpose submitted, and no part of this document or its contents shall be reproduced, published, ordisclosed to a third party without the express permission of Honeywell International Srl.While this information is presented in good faith and believed to be accurate, Honeywell disclaims the impliedwarranties of merchantability and fitness for a purpose and makes no express warranties except as may be statedin its written agreement with and for its customer.In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The informationand specifications in this document are subject to change without notice.Copyright 2015 - Honeywell International Srl

    2 www.honeywell.com

  • Contents

    1 Introduction ............................................................................................................................................ 51.1 About the document ............................................................................................................................................ 6

    1.1.1 Revision history ................................................................................................................................... 61.2 About Experion R430.3 ...................................................................................................................................... 7

    1.2.1 Controllers and Tools resolved PARs .................................................................................................. 71.2.2 Common Components resolved PARs ................................................................................................. 81.2.3 Servers and Stations resolved PARs .................................................................................................... 91.2.4 Issues .................................................................................................................................................. 141.2.5 Limitations ......................................................................................................................................... 15

    1.3 Before you begin .............................................................................................................................................. 161.3.1 Prerequisites ....................................................................................................................................... 161.3.2 Experion PKS R430.3 installation or upgrade checklist ................................................................... 161.3.3 Applicable nodes ............................................................................................................................... 161.3.4 Applicable modules ........................................................................................................................... 171.3.5 Supported controller migration paths ................................................................................................ 171.3.6 Verifying the present version ............................................................................................................. 181.3.7 Copying the Experion PKS R430.3 ................................................................................................... 18

    1.4 Change impact .................................................................................................................................................. 201.4.1 Control change impact ....................................................................................................................... 201.4.2 Operational change impact ................................................................................................................ 201.4.3 Infrastructural change impact ............................................................................................................ 21

    2 Experion PKS R430.3 installation ....................................................................................................... 232.1 Installing the point release on non-redundant server node ............................................................................... 242.2 Installing the point release on redundant server ............................................................................................... 27

    2.2.1 Installing the point release on Server B ............................................................................................. 272.2.2 Installing the point release on Server A ............................................................................................. 30

    2.3 Installing the point release on Experion Application Server/ Console/Flex/Console Extension station/eServer/Premium Access clients ....................................................................................................................... 35

    2.4 Installing the point release on ACE or SCE ..................................................................................................... 392.5 Migrating controllers ........................................................................................................................................ 42

    2.5.1 Updating the firmware ....................................................................................................................... 422.5.2 Firmware revision .............................................................................................................................. 42

    3 Experion PKS R430.3 removal ............................................................................................................ 454 Notices .................................................................................................................................................. 47

    4.1 Documentation feedback .................................................................................................................................. 484.2 How to report a security vulnerability .............................................................................................................. 494.3 Support .............................................................................................................................................................. 504.4 Training classes ................................................................................................................................................. 51

    3

  • CONTENTS

    4 www.honeywell.com

  • 1 Introduction

    Related topicsAbout the document on page 6About Experion R430.3 on page 7Before you begin on page 16Change impact on page 20

    5

  • 1.1 About the documentThe Software Change Notice describes the prerequisites, resolved PARs, applicable nodes, and steps to install/uninstall the point release. Additionally, the SCN contains information about the change impact and additionalinformation for this point release. The latest version of this SCN is always available on the Honeywell ProcessSolutions website.

    1.1.1 Revision historyVersion Date DescriptionA November 2014 Initial version.B December 2014 Updated section 1.3.1.C December 2014 Updated ML Server version in section 1.3.1.D January 2015 Updated section 1.3.5.E February 2015 Updated section 1.3.5.

    1 INTRODUCTION

    6 www.honeywell.com

  • 1.2 About Experion R430.3Experion R430.3 addresses problems and/offers improvements requested since the release of Experion R430.2.

    Attention Controller firmware upgrade or migration is only required if the system is experiencing one or more problems

    resolved in Section 1.2.1 Controller and Tools. If you intend to upgrade or migrate controllers, ensure to contact HPS Migration helpdesk (MHD) at least four

    weeks before you install the Experion PKS R430.3 point release. Experion R430.3 Software Change Notice includes a prioritized Product Anomaly Reports (PARs) summary.

    Please contact the Honeywell TAC for assistance if you observe issues not covered in this SCN.

    1.2.1 Controllers and Tools resolved PARsPAR Subsystem Description Patch Name

    1-2C30VPX Control Builder-HART On assigning the ST800 DD to AI channel, ST800device channel does not get listed in Synchronizemaintenance mode. Functionality of Maintenancemode is not as intended, even if you change the valueof PVSOURCE to MAN, device does not changestatus to Available for Maintenance.

    Not Applicable

    1-1WLAF8S Control Builder-HART The Maintenance Mode feature is supported for ST800 device, same support is needed for new devices.

    Not Applicable

    1-2QMSC33 I/O-PMIO On loading PMIO HART IOP with channelsconfigured, the IOP stops responding.

    Not Applicable

    1-2L9TNO2* SCM-Sequential ControlModule

    After migrating Experion R301 to Experion R410,Sequential Control Module (SCM) stops respondingin the last block on passing through InterruptHandler.

    Not Applicable

    1-3216DAX Control Builder-SystemRepository

    System Repository cache does not allow concurrentaccess to multiple reader clients, resulting inperformance issues.

    Not Applicable

    1-1CJWAQU Control Builder-Listview The Listview grid is not populated if you enter wildcard characters in BlockType combo box.Additionally, you cannot enter characters manually inone attempt in BlockType combo box.

    Not Applicable

    1-32EKX13* Turbine Control In SVPM_PID block there is no method to detectmaximum Process Value (PV) between PV1 andPV2.

    Not Applicable

    1-32DTMMI* ModBus TCPInfrastructure PCDI Channel may fail on device switchover.

    Not Applicable

    1-2TMVGBP* Network-FTE Bridge FTE status Display for FTEB node displayserroneous failures. On FTE tab, the address countand node count are different than expected for systemconfiguration.

    Not Applicable

    1-387VNPT OPM-Interoperability The installation of Experion PKS R410.5 ControllerPatch Controlled Release 1 takes more than one hourto complete and you see a message displayed asfollows,Gathering required information.

    Not Applicable

    1-2Z18MCB* CF-Control Function The TypeConvert block uses the same input unionstructure and is unable to perform successfulinitialization.

    Not Applicable

    1 INTRODUCTION

    7

  • PAR Subsystem Description Patch Name1-389EDDB* SIM-FFD For the process completeness need to merge the

    SIMFFD changes already done for UNISIM-SIMFFD Project Special (R410.2) in Experionrelease R410.6.

    Not Applicable

    1-39L3HRS* C300 Controller On changing MODE to single step in control recipe,C300 controller stops responding.

    Not Applicable

    1-2USKQFZ Control Builder-Configuration Form

    Importing latest Device Description files in ControlBuilder fails.

    Not Applicable

    1-3DO00CT CDA-Control Data Access There is a delay in server switchover, on the removalof CNET cables from primary server.

    Not Applicable

    1-37KXN75 Enterprise Model Builder You face problems with EMDB/ERDB backups fromDB admin.

    Not Applicable

    1-3EBF4CF* I/O-Series C CC-PAOH51 and CC-PAIH051 fails with noresponse.

    Not Applicable

    1-3E9XZ8B Control Builder An error message is displayed on certain SCM, onswitching to the table view.

    Not Applicable

    1-3F9FGIP CDA-Control Data Access System Repository logs overflow with notificationsrelated to PMD points.

    Not Applicable

    1-3ELCVIH CDA-Control Data Access Backup System Repository loses synchronizationwith primary.

    Not Applicable

    1-3EBPQQD OPM-Upgrade Tool Some readiness checks are missing for server B, onmigrating the cluster from R400.2 to R431.1 TP2.0release.

    Not Applicable

    1-3EFPCBB* Simulation environments You cannot change the SIMCOMMAND usingAPPDEVELOPER access level for SIM-ACE.

    Not Applicable

    1-30J55WA Simulation environments USO stops responding on saving IC, OL andbacktrack snapshots.

    Not Applicable

    1-2SIJTKB SIM-FFD Issues are seen on saving USO snapshot w.r.tSIMFFD.

    Not Applicable

    1-3IVYNZL INS-Experion Installer R430.3 installation fails and displays the followingerror unable to read the status file forComms_Changer.

    Not Applicable

    * Requires firmware to be updated.

    1.2.2 Common Components resolved PARsPAR Subsystem Description of the problem Patch Name

    1-1RY56DF System Management On the Port status tab for C2960 CISCO switchesCANE Display, port 1 status is not displayed.

    Not applicable

    1-U16Q4K HMIWeb TPN Details The BADPVPR parameter fails to appear in theHMIWeb TPN Detail for NIM RegPV and analoginput points.

    Not applicable

    1-3EPVYK9 INS-Experion Installer An error message is displayed while installingR430.2 cumulative patch on domain controller node.

    Not applicable

    1-3GFVVVJ Safeview SafeView configures Experion multi-windowcommand window slightly too tall, leaving whitespace at the bottom of the command window.

    Not applicable

    1 INTRODUCTION

    8 www.honeywell.com

  • PAR Subsystem Description of the problem Patch Name1-US9Q99 Safeview In SafeView when two windows are configured as

    always-on-top, and then one of those is dragged ontop of the other and then closed, the underlyingDisplay does not automatically refresh to clean upthe overlapping area.

    Not applicable

    1-3J7WC2B Experion Station-Faceplate Experion TPS DIGCOMP faceplate may enterinfinite loop and Station may stop responding.

    Not applicable

    1.2.3 Servers and Stations resolved PARsStation

    PAR Subsystem Description Patch Name1-2YA12Y3 Alarm Pager Notifications from pre-R410 DSA publishers do not

    get paged on R410 subscribers.Not applicable

    1-2ZWUKGV Alarm Pager Emails generated by Alarm pager do not contain theserver machine name as part of the email subject.

    Not applicable

    1-2KWQ47Z Console Station Server logs are flooded with message"dsnotifsync_silence() .. can only be called on acluster server or console station" on a systemwithout a Console Station license.

    Not applicable

    1-3GB5B1J Console Station In rare circumstances, acknowledging an alarm on aConsole Station does not cause the alarm to beacknowledged on another Console Station.

    Not applicable

    1-2VKUPAN Displays If a channel or controller is enabled or disabled, itmay take up to 60 seconds before this change is seenon the SCADA controllers Display that is open onanother station.

    Not applicable

    1-2WT851D Displays Printing options in syscfgoperadvanced.htm file areworking in reverse.

    Not applicable

    1-3GEKLPH Displays Associated parameter name for auxiliary parametersis truncated on analog point detail Display.

    Not applicable

    1-3G8V8JL Distributed ServerArchitecture

    On DSA subscriber, alarm aggregation from SCADApoints to equipment point stops after schematic viewis opened.

    Not applicable

    1-3G99397 Equipment Manager Pipeline Flow Snapshot can occasionally not load onDSA subscriber after initial Tag Synchronization.

    Not applicable

    1-3H86HAZ Licence Management Secure Comms embedded and Windows count do notneed scaling factor and require limits of 1023 & 1270respectively.

    Not applicable

    1-3F56LNN Notifications Configuration Studio logon and lockout systemalarms incorrectly appear on the process alarmsummary.

    Not applicable

    1-2EQR3T5 Notifications Alarm help faceplate does not show alarm conditionsfor status points.

    Not applicable

    1-2MQ9CMD Notifications Alarm condition is not automatically pre-selected onthe alarm help faceplate if the type case forcondition/block text in Experion and ACM does notmatch exactly.

    Not applicable

    1 INTRODUCTION

    9

  • PAR Subsystem Description Patch Name1-2QSHAJ9 Notifications Alarm Help faceplate may show incorrect list of

    conditions if there are points in the system withsimilar names.

    Not applicable

    1-2SLZFQT Notifications Alarm Help faceplate shows conditions/boundariesthat are not configured in ACM.

    Not applicable

    1-30G9RSN Notifications Events from Assets are not displayed in EventSummary when View Without Alarm permission isgiven.

    Not applicable

    1-3268BKV Notifications Alarm tracker does not show alarms in an alarmgroup for points that have been directly added to analarm group.

    Not applicable

    1-HJIEOJ OPC/ODBC PHD logs can fill with thousands of error messagesduring history recovery of an Experion server.

    Not applicable

    1-ZXQDVD OPC/ODBC Introduce throttling into the ODBC driver to preventoverload from queries made against all points.

    Not applicable

    1-2IDCJZ7 OPC/ODBC GdaMngr may restart unexpectedly if it disconnectsfrom an OPC server.

    Not applicable

    1-2L438J9 OPC/ODBC Parameter discovery is being attempted via the OPCAdvanced Client connection associated with aSCADA OPC client channel.

    Not applicable

    1-3FDF25D OPC/ODBC Group marginal alarms are raised with a 'FAILED'condition.

    Not applicable

    1-3F91IIH OPC/ODBC During point download or server failover events canbe generated indicating OPC SCADA client pointparameter values are chattering.

    Not applicable

    1-2Q4LR5V Operational Applications Alarm aggregation does not work for someequipment as the AlarmAggregation attribute is notdefined correctly.

    Not applicable

    1-2G5YGYJ PHD Integration Experion Tag Sync Server may terminateunexpectedly when background monitors TPS tags.

    Not applicable

    1-2UCAWQ9 PHD Integration Experion Tag Sync Server to provide CMengineering units to PHD if no block engineeringunits are defined.

    Not applicable

    1-1PQEDWF SCADA Interfaces HC900 Set point trend may not be drawn if segment1 is a RAMP and ramp type is RATE.

    Not applicable

    1-20Y1IH9 SCADA Interfaces Implement transaction IDs for Modbus TCP toimprove robustness to communication delays.

    Not applicable

    1-3F60F7F SCADA Interfaces Parameters configured with 0 scan period may appearas stale.

    Not applicable

    1-3GEEIS3 SCADA Interfaces After entering a new SP or OP value to a slow OPCcontroller, station shows old value followed by thenew value.

    Not applicable

    1-3GEEITR SCADA Interfaces Values with quality 0xD8(OPC_QUALITY_GOOD_LOCAL_OVERRIDE)are shown as bad in station.

    Not applicable

    1-3GYNZW3 SCADA Interfaces Old and new values are not being output in EnronModbus events for EFM Exports to FLOWCAL.

    Not applicable

    1-3GYNTOH SCADA Interfaces There is a rare chance that some EFM records maynot get exported if the meter's laying down of recordscoincide with EFM collection.

    Not applicable

    1 INTRODUCTION

    10 www.honeywell.com

  • PAR Subsystem Description Patch Name1-3GYNTLF SCADA Interfaces History start and end date in CFX only covers history

    fields and does not include audit log events.Not applicable

    1-3GYLZ89 SCADA Interfaces After a meter has been disabled for more than asingle scheduled collection, on enabling, the meterextra collections can be performed every minute forsome period of time, based on number of collectionsmissed.

    Not applicable

    1-3GYNTTR SCADA Interfaces EFM export to CSV may show extra significantdigits for field values that were of type REAL in themeter.

    Not applicable

    1-3H8A9FT Server DatabaseEngineering

    Databld clearall def dataformat command clearsdefault value of width 16 to 0 in all the records.

    Not applicable

    1-3HAEHG9 Server DatabaseEngineering

    Equipment which have inherent controllers in themthrows warnings during downloads.

    Not applicable

    1-3H8B21T Server DatabaseEngineering

    Databld throws error on performing export fordataformat, if Data type configured as REAL8.

    Not applicable

    1-23WRRT1 TPS Interface If TPN server automatic restart is triggered, Experionserver fails over to backup.

    Not applicable

    1-31L53A3 TPS Interface With the option All TPS alarms are monitored byat least one experion station disabled, TPS alarmsdo not get acknowledged automatically on the ESVT.

    Not applicable

    1-31VJXYP Station Station may stop responding following a script errorafter right clicking on an MS Excel worksheet loadedin an Active X document element.

    Not applicable

    1-3G513MV Station Station does not annunciate alarms via the alarm lighton Orion Console.

    Not applicable

    1-VL3WCU Station Plantscape displays loaded in Experion Station maynot respect DSPZoomingAllowed setting and appearto scale incorrectly.

    Not applicable

    1-QDQ4UR Station Faceplates/popups launch via script inOnPageComplete may not load, or may not bemanaged by SafeView in multi window station.

    Not applicable

    1-1I0D4J1 Station The first tab of point detail Display gets loaded indifferent window when using back-forward toolbar inMultiwindow station with multiple command zones.

    Not applicable

    1-35VLWYF Station Station reports missing background shape in the logswhen navigating to any HMIWeb Display.

    Not applicable

    1-3H1EQ7D Station Pan and zoom displays that contain nested shapesmay not show data values.

    Not applicable

    1-3FKJ1I5 Station Attempt to write a string containing invalid formatspecifier to HMIWeb log file from within displayscript may cause HSCStationWindow to stopworking.

    Not applicable

    1-1013ZU1 Station OnShapeLoad event may not fire on a shape aftercalling SetCustomProperty.

    Not applicable

    1-2YDKLRT Station Tabbed Displays may not be available whenmultiwindow station connects using auxilaryconnection file.

    Not applicable

    1-3AGY5VR Station Faceplates sometimes appear without any titlebarwhen using Tabbed Displays in Multi-WindowStation.

    Not applicable

    1 INTRODUCTION

    11

  • PAR Subsystem Description Patch Name1-2DJXPRR Station Station menus are disabled once you pass a certain

    hard coded threshold for the number of commands inthe toolbar file.

    Not applicable

    1-2PTB9IH Faceplates/Popups Occasionally more than one faceplate may getinvoked for the same point.

    Not applicable

    1-2WI8XNP Faceplates/Popups On nodes running multiple instances of singlewindow station, new faceplates may fail to launchafter a while.

    Not applicable

    1-3GTOXLP Faceplates/Popups Occassionally IKB/OEP keys don't work sometimesin Single Window Station Faceplates.

    Not applicable

    1-1VIZF5L Chart/Trend Tabular history grid displays wider columns when aTrend configured on 1280x1024 resolution is loadedon screen with 1900x1200 resolution.

    Not applicable

    1-Y3ESAR Printing Need to give focus to display after launching afaceplate for Print actions to work in single windowstation.

    Not applicable

    1-30B20GT Printing The default footer refers to PrintTemplate.html whenusing metafile printing method in station.

    Not applicable

    1-YF3SXX Printing Station must try to read the display background colorfrom HKCU registry location before reading fromHKLM to allow an operator to choose their ownpreferred color.

    Not applicable

    1-VHDOXD Printing Entries added to the Station.ini file to disable theAlarm Bar and Status Bar print options do not work.

    Not applicable

    1-1C14VOX Notification Presentation Occasionally station stops responding on doubleclicking events and tooltips shown on screen for lessthan 1 second.

    Not applicable

    1-2I1758P Notification Presentation Shelved, suppressed or disabled alarm icon may notprint on printer.

    Not applicable

    1-3ED3HVP HMIWeb Display Builder In some cases custom property references in scriptsfor display elements and shapes may not migratecorrectly.

    Not applicable

    1-1G2BAQP HMIWeb Display Builder Migrated HMIWeb displays containing combinedelements having an embedded image fail to load theimage when uncombined.

    Not applicable

    1-3H1KPBJ HMIWeb Display Builder Pan and Zoom displays containing alarm icons withscript data attached may result in script errors in thethumbnail.

    Not applicable

    1-1VBW7V3 HMIWeb Display Builder HMIWeb Display builder may stop responding whennavigating to the script data tab on a system with alarge number of points.

    Not applicable

    1-3H3FTA9 HMIWeb Display Builder Roundness attribute for HMIWeb rounded rectangleelements should be configurable via stylesheet.

    Not applicable

    1-15CEP1N Keyboard Alphanumerics on a faceplate may become non-editable after performing select and drag operation.

    Not applicable

    1-2RW99OX eServer Standard Access Page callup via eServer Standard Access may failafter some period of time.

    Not applicable

    1-11QM24P eServer Standard Access Value specified for eServer URL in eServer StandardAccess Configuration panel does not take effect onthe system.

    Not applicable

    1 INTRODUCTION

    12 www.honeywell.com

  • PAR Subsystem Description Patch Name1-19AD7AU eServer Premium Access Internet Explorer may stop working when attempting

    to login after timeout.Not applicable

    1-3GEG0C5 Quick Builder After importing special symbols in ASCII code table(like Celsius degree symbol), Quick Builder displaysthem differently that are not recognizable.

    Not applicable

    1-3H6M7DD Quick Builder Part of the text displays are truncated whenconfiguring a universal modbus channel with porttype Terminal server.

    Not applicable

    1-3H6M7GZ Quick Builder Provide configuration for Transaction ID option forModbus.

    Not applicable

    1-3H6MDJB Quick Builder Some units for a few parameters of Bristol Babcockand Bristol Babcock open BSI Controller are notdisplayed in the property panel.

    Not applicable

    1-2FRF63X Quick Builder Paste item back from Excel must ask userconfirmation if the item already exists in the QuickBuilder.

    Not applicable

    1-3H6MDKP Quick Builder Export All items relevant to file typedoes not exportsome of the controllers and points when you haveequipments in your project.

    Not applicable

    1-37OTH0B Quick Builder Quick Builder Modbus controller definition doesn'tsupport use of non-default port number.

    Not applicable

    1-3AHE8C7 Quick Builder Quick Builder cannot be launched after changing thecluster from day light saving time to normal time.

    Not applicable

    1-3H6KX3T Quick Builder Importing top of equipment template points does notupdate all relationships with multiple entries.

    Not applicable

    1-NCGHC1 Configuration Studio Cannot see block/condition dropdown and cannotload DAS configuration to DSA servers in differentsubnet where multicast cannot reach.

    Not applicable

    1-3JXDLUR HMIWeb Station -General

    Audible annunciations stop even if there are stilloutstanding active alarms on a station when anyalarm is acknowledged from a different station.

    Not applicable

    Server

    PAR Subsystem Description Patch Name1-3GEHDTJ Operational Applications Current value of Compressor Map Display

    occasionally drifts to the (0,0) point despite historynot being recorded as these values.

    Not applicable

    1-3GYMPQ5 Server History Exception History Manager process can sometimesfail to restart successfully upon a failover.

    Not applicable

    1-3GYNTVF SCADA Interfaces Gas Quality and Composition logs output in FlowCalGQSOURCE format are stored in the incorrectlocation and hence they will not be processed byFlowCal.

    Not applicable

    1-3HA2TI7 OPC/ODBC Decimal deadband values are rounded off onvalidating group.

    Not applicable

    1-3HCA923 SCADA Interfaces ANA point alarm limit 7 is not preserved duringupgrade to Experion R430, from pre R410.

    Not applicable

    1 INTRODUCTION

    13

  • 1.2.4 IssuesPARs Subsystem Description1-388NOFF System Management Description: The following error message is displayed 810 times, if the

    location containing the contents of the Experion_PKS_R430_X.zip fileexceeds 14 characters.MsiGetProperty(CustomActionData) failedRecovery: None.Workaround: Acknowledge the error message by clicking OK and proceedwith the installation.

    1-3E2990A Quick Builder Description: Quick Builder upload fails when alarm limit value is NaN.Recovery: None.Workaround: Use numeric values for alarm limit values.

    1-3FSWFYF Quick Builder Description: It is not possible to have SCADA RTU and EMDB asset withsame names.Recovery: None.Workaround: Do not use the same name for asset and controller.

    1-3IMPGMP HoneywellCommunicationsInterface

    Description: tpndss.exe leaks memory following repeated OPC clientconnection attempts when LCN connection is down.Recovery: Enable LCN connection.Workaround: Stop OPC client connection attempts to TPN Server whenLCN connection is down. OPC client connections will fail when TPN Serverhas no LCN connection thus there is no purpose in attempting connection.

    1-3HDCDNZ HMIWeb DisplayBuilder

    Description: Use of Convert scripts for Message zone prompts into Calloutsoption in Bulk Display Migrator may result in incorrect script on the migratedDisplays. This option has been disabled in R430.3.Recovery: Refer to the Priority Notification 2014-31, https://www.honeywellprocess.com/library/support/notifications/Customer/pn2014-31_bulk_display_migrator_issue_callout_script.pdf for furtherdetails.Workaround: None.

    1-3IM128N System Management Description: Analysis of the FTEProvider process shows memory leak inMicrosoft code, and Microsoft has been engaged to analyze and diagnose thememory leak. The leak is visible by observing the memory usage for theFTEProvider.exe process in Windows Task Manager.Recovery: Reboot the node when the memory usage of FTEProviderbecomes high enough to impact other processes running on the system.Workaround: Same as the recovery.

    1-3IOLFFF System Management Description: Analysis of the syncrep process displays memory leak inMicrosoft code, and Microsoft has been engaged to analyze and diagnose thememory leak. The leak is visible by observing the memory usage for theSYNCREP process in Windows Task Manager.Recovery: Reboot the node when the memory usage of syncrep gets highenough to impact other processes running on the system.Workaround: Same as the recovery.

    1 INTRODUCTION

    14 www.honeywell.com

  • PARs Subsystem Description1-3L3DW3G Network-FTE Description: FTE issue is observed during R430.2 patch installation after

    applying cumulative patch R430.2 from R430.1. The Honeywell FTE MuxAdapter does not have any IP address and the subnet mask does not allow anyvalues except 255.255.255.255. This is caused when the initial IP address ofthe Yellow adapter is set to DHCP by the Initialization Media and is thenchanged after Experion PKS installation is completed.Recovery:None.Workaround: This situation requires the Yellow adapter settings to be fixedbefore the cumulative patch is installed. To determine if this issue exists, youneed to answer the following two questions.1. Did this computer upgrade from R430.1 to R430.2 without any problems?

    If Yes, continue with the migration to R430.3 point release.2. Was the Honeywell Adapter configured to a fixed IP address from DHCP

    after the initial installation was completed?ORWas the computer initialized without configuring the IP Address? If yes,then the computer may become unstable after upgrade.

    If the answer to question 2 is Yes or unknown, contact the Migration HelpDesk (MHD) for further assistance before migrating to R430.3.

    1-33Y4ZQL CTools Description: CTools does not prevent C300 bricking when migrating toR430.1.Recovery: Contact TAC for support.Workaround: You can refer to PN 2014-21 https://www.honeywellprocess.com/library/support/notifications/Customer/pn-2014-21-r430.1-c300-controller-migration-firmware-update-issue.pdf forrecommendations and actions.

    1.2.5 LimitationsPoint release removal

    [ ] Automatic [ ] Can be done manually during next upgrade [ ] Must be done manually before next upgrade

    Localization

    [ ] Not impacted [ ] Point release may contain strings in English. A Localizationversion to be included in the next release.

    [ ] Needs localization support

    Point release distribution

    [ ] Not limited [ ] Limited

    1 INTRODUCTION

    15

  • 1.3 Before you begin

    1.3.1 PrerequisitesExperion PKS R430.3 can be installed on a node on which the following Experion release is installed: Experion PKS R430.2 Experion PKS R430.1

    AttentionBefore installing this point release, enable Windows Firewall.If you are migrating from R4xx or prior, then you MUST download and install the R430.1 Server Database MigrationUtility from the link https://www.honeywellprocess.com/library/support/software-downloads/Experion/Experion%20PKS%20R430.1%20Server%20DB%20Utility.zip.Starting R430.x ML Server versions are not forward or backward compatible, hence if you are using the Honeywell ML Server interface, ensure that you upgrade to the appropriate ML Server version. Refer the following table for more details.

    ML Server Version R430.1 R430.2 R430.31.5.0.3 Yes No No compatible version available.1.5.0.5 No Yes

    1.3.2 Experion PKS R430.3 installation or upgrade checklistUpgrading to Experion PKS R430.3Task ReferenceCheck the applicable nodes. Refer to the section Applicable nodes in this SCN.Install Experion PKS R430.3 on the applicable nodes. Refer to the section Experion PKS R430.3 installation on

    page 23 in this SCN.

    1.3.3 Applicable nodesThis Experion PKS R430.3 is applicable for the following nodes.Sl.No. Node Is Experion PKS R430.3

    applicable?1 Application Server (EAS) Yes2 Application Control Environment (ACE) Yes3 Application Control Environment TPN Connected (ACET) Yes4 Console Station (ES-C) Yes5 Console Station TPN Connected (EST) Yes6 Console Extension Station (ES-CE) Yes7 Experion Server (ESV) Yes8 eServer Yes9 Experion Server TPN Connected (ESVT) Yes10 Experion HiWay Gateway (EHG) Yes

    1 INTRODUCTION

    16 www.honeywell.com

  • Sl.No. Node Is Experion PKS R430.3applicable?

    11 Experion Application node. (E-APP) Yes12 Flex Station (ES-F) Yes13 Simulation Control Environment (SCE) Yes

    1.3.4 Applicable modulesThe Experion PKS R430.3 is applicable for the following modules.Sl.No. Module Is Experion PKS R430.3

    applicable?1 Enhanced High-Performance Process Manager (EHPM) Yes2 C200E controller Yes3 C300 controller Yes4 Fieldbus Interface Module (FIM) Yes5 Fieldbus Interface Module (FIM) 4 Yes6 Fieldbus Interface Module (FIM) 8 Yes7 Fault Tolerant Ethernet Bridge Module (FTEB) Yes8 Experion Hiway Bridge (EHB) Yes9 IO Link Interface Module (IOLIM) Yes10 PROFIBUS Gateway Module (PGM) 2 Yes

    1.3.5 Supported controller migration pathsThe following controller migration paths to Experion PKS R430.3 are supported.Item No. Controller path1 Experion R310.2 Controller Patch 12 Experion R310.3 Controller Patch 33 Experion R310.3 Controller Patch 44 Experion R310.3 Controller Patch 55 Experion R310.3 Controller Patch 66 Experion R310.3 Controller Patch 77 Experion R311.2 Controller Patch 18 Experion R311.2 Controller Patch 29 Experion R311.2 Controller Patch 310 Experion R311.311 Experion R311.3 Controller Patch 112 Experion R311.3 Controller Patch 213 Experion R311.3 Controller Patch 314 Experion R311.3 Controller Patch 415 Experion R311.3 Controller Patch 516 Experion R311.3 Controller Patch 617 Experion R311.3 Controller Patch 7

    1 INTRODUCTION

    17

  • Item No. Controller path18 Experion R400.119 Experion R400.1 Controller Patch 120 Experion R400.1 Controller Patch 221 Experion R400.1 Controller Patch 322 Experion R400.223 Experion R400.2 Controller Patch 124 Experion R400.2 Controller Patch 225 Experion R400.2 Controller Patch 326 Experion R400.2 Controller Patch 427 Experion R400.2 Controller Patch 528 Experion R400.2 Controller Patch 629 Experion R400.2 Controller Patch 730 Experion R400.2 Controller Patch 831 Experion R400.332 Experion R400.433 Experion R400.534 Experion R400.635 Experion R410.136 Experion R410 Controller Patch 337 Experion R410 Controller Patch 438 Experion R410.239 Experion R410.340 Experion R410.2 Rev241 Experion R410.442 Experion R410.543 Experion R430.144 Experion R430.2

    1.3.6 Verifying the present versionTo verify the present version1 Using Notepad, open the ProductVersion.txt file located in the following path.

    \Honeywell\Experion PKS (for example, C:\Program Files(X86)\Honeywell\Experion PKS)

    2 Verify the ProductVersion.txt for the following:Ensure that the following lines are present. If the following lines are present, the node has the appropriateproduct version to install this patch. +Experion PKS R430.1 Support Media Install completed on MM/DD/ YYYY HH:MM:SS AM/PM +Experion PKS R430.2 Install completed on MM/DD/ YYYY HH:MM:SS AM/PM

    1.3.7 Copying the Experion PKS R430.3Perform the following steps.

    1 INTRODUCTION

    18 www.honeywell.com

  • 1. Copy the Experion_PKS_R430_3.zip file to a temporary folder on your hard disk.2. Extract the Experion_PKS_R430_3.zip file.3. Copy the extracted files to a temporary folder on your hard disk.

    AttentionThe character count for the location containing the contents of the zip file must not exceed 14 characters.For example, when you copy the files to C:\temp\update the character count is 14.For more information, refer to PAR 1-388NOFF under section Issues on page 14.

    NoteIf you have installed the Whitelisting application, ensure that you follow the procedure mentioned in theWhitelisting guide prior to the patch installation.

    1 INTRODUCTION

    19

  • 1.4 Change impact

    Related topicsControl change impact on page 20Operational change impact on page 20Infrastructural change impact on page 21

    1.4.1 Control change impactNot applicable.

    1.4.2 Operational change impactTera Term to replace HyperTermStarting with R430.3, HyperTerm/HyperTerminal emulator is discontinued and Tera Term terminal emulator isincluded with Experion. You must use Tera Term for all terminal emulator needs, including communication withCisco switches. If HyperTerm is installed, discontinue its use and remove it from your system. Note thefollowing: Experion supports Tera Term version 4.82. Tera Term can be installed on any node that is used for configuring the FTE switches. Tera Term is available on the Experion media set and can be installed based on requirement. It is not

    automatically installed as part of Experion installation. Tera Term is also available on Honeywell Process Solutions website for installation and use with previous

    releases of Experion.PAR 1-YF3SXXThe resolution of this PAR allows the printing preferences to be set for each user through the HKCU registrysetting.The following registry settings if present takes preference over the settings in HKLM.[HKEY_CURRENT_USER\Software\Wow6432Node\Honeywell\Station] "PrintMethod"="Metafile""PrintBackgroundColor"="Transparent"PAR 1-2ZWUKGVAlarm pager e-mail subject now contains the server machine name. This brings Experion R430 release in linewith earlier Experion releases.PAR 1-2UCAWQ9The Experion Tag Synchronization server now provides the Control Module's engineering units to PHD if noFunction Block engineering units are applicable or configured.Previously if the engineering units were not applicable to the Function Block type or if the Function Blockengineering units were left blank, then the Experion Tag Synchronization server would have sent an emptystring to PHD as the engineering units.PAR 1-ZXQDVDCurrently ODBC Driver lists all the TPS, Point Server and Remote points while querying the Flexible pointtable. Remote points can now be excluded from the Flexible Point table query if required.

    1 INTRODUCTION

    20 www.honeywell.com

  • 1.4.3 Infrastructural change impactNot applicable.

    1 INTRODUCTION

    21

  • 1 INTRODUCTION

    22 www.honeywell.com

  • 2 Experion PKS R430.3 installation

    NoteIf you are using Experion Support and Maintenance (ESM) to install the point release on the Experion cluster, addthe point release to the ESM Server. For more information, refer to the Installation Builder User's Guide.

    Related topicsInstalling the point release on non-redundant server node on page 24Installing the point release on redundant server on page 27Installing the point release on Experion Application Server/ Console/Flex/Console Extension station/eServer/Premium Access clients on page 35Installing the point release on ACE or SCE on page 39Migrating controllers on page 42

    23

  • 2.1 Installing the point release on non-redundant server nodeAttentionInstalling Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool fromStart > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKSStart-Stop Services Control Panel tool to stop all services manually.

    To stop the services1 Log on to the server using an account that is part of both the Windows Administrators and Product

    Administrators group.AttentionEnsure that you log on with the mentioned required privileges.

    2 For systems with licensed QVCS only: Open the QVCS Manager application and complete the requiredQVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Managerapplication manually.

    3 Perform the following Checkpoint tasks.a Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.

    AttentionAny currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automaticor manual Checkpoint Save tasks are complete.

    b Ensure that the Checkpoint share has replicated correctly to all the Console stations.c To verify the replication of the Checkpoint shares, check the Event Summary Display page on the

    Station after the manual/auto Checkpoint Saves are completed for all controllers. If the EventSummary Display page does not display any replication failure event, the replication is successful.

    4 Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recoveryservice (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.

    AttentionYou must enable the services after completing the procedure.

    5 Close all the running applications.6 If RSLinx is installed, perform the following steps to stop RSLinx for systems using ControlNet.

    a On the desktop, right-click My Computer and select Manage.The Computer Management window appears.

    b Expand Services and Applications in the left pane.c Click Services.

    The list of services appears in the right pane.d Perform the following steps.

    1. Right-click RSLinx Classic and select Stop.2. Right-click Harmony and select Stop.

    e Close the Computer Management window.

    To install the point Release To install, perform the following steps.

    2 EXPERION PKS R430.3 INSTALLATION

    24 www.honeywell.com

  • a If you are using Experion Support and Maintenance (ESM) to install the point release, install the pointrelease from the ESM client. For more information, refer to the Installation Builder User's guide. If youare not using ESM to install the point release, go to step b.

    b Ensure that you are logged on using an account that is part of both the Windows Administrators andProduct Administrators group.

    c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKSR430.3 > supportsoftware.exe. If the installation is from the network then map the location where theinstaller folder is located to the network drive.

    Attention1. In the command prompt, as an Administrator, type the following command.

    net use : \\computername\share\ (for example, net use Z: \\199.63.5.151\temp\ExperionPKS R430.3 )Ensure that the path mapped (for example, \\199.63.5.151\temp\) has both Read andWrite permissions.

    2. Type the user name and password (must be in quotes if there is a blank).3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.

    d Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Controldialog box is displayed, click Yes to continue.The Welcome to Experion PKS Update Manager dialog box appears.

    e Click Install to start the Experion PKS R430.3 installation.Attention During the installation, when the system restarts, manually log on to the system with the required

    credentials to continue with the installation. If the installation is being performed from the network, after each system restart, map the drive to continue

    the installation. To map the drive, perform the steps as given in the Attention of Step b. You may see the following error message related to service which cause the installation to abort. Stop the

    service manually after acknowledging the message and restart the installation.Failed to stop . Installation will be aborted now.

    f Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

    To validate the installation To verify if the Experion PKS R430.3 is installed, perform the following steps:

    a Using Notepad, open the ProductVersion.txt file located in the following path.C:\Program Files(X86)\Honeywell\Experion PKS OR \Honeywell\Experion PKS.

    b Verify the ProductVersion.txt for the following:+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PMIf the above line is present, it indicates that the installation is successful.

    NoteAfter Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that thesystem is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, youmay also see previous Experion release references in the product info.

    Post-installation tasks1 Log on as a member of Windows Administrators and Product Administrators group.2 Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.3 Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery

    service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must beenabled.

    2 EXPERION PKS R430.3 INSTALLATION

    25

  • 4 Enable all the Checkpoint tasks.

    To update Common Components packages (optional step)1 Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.

    AttentionNote that these steps must be performed ONLY if you install an optional common component package afterinstalling Experion PKS R430.3. The steps must be performed to update the installed optional common componentpackage version to Experion PKS R430.3 version.

    2 Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installerExperion PKS R430.3.

    3 Browse to the respective sub folder containing the common component packages folder.4 Choose Start > All Programs > Accessories > Command Prompt.5 Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.6 In the Command Prompt, enter the path of the common components update with the update name and click

    ENTER.7 The common component update is installed. Updates to following common components are available.

    AppTPSBase Cl Server AppTPSClient AppTPSSolution Experion Remote Native Window Honeywell FTE MUX Driver Experion GUS Display Builder Experion GUS Display Runtime Experion GUS Remote displays Honeywell HCI Runtime Honeywell IKB Service Honeywell Redirection Manager Honeywell SafeView Honeywell Signon Manager Honeywell System Management Runtime Honeywell TPS Domain Console Configuration Honeywell File Transfer - Client Honeywell File Transfer - Server

    AttentionSUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It ismandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fixKB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install theMicrosoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://support2.microsoft.com/kb/2925489.

    2 EXPERION PKS R430.3 INSTALLATION

    26 www.honeywell.com

  • 2.2 Installing the point release on redundant serverFor redundant servers, you must first install the point release on Server B and then on Server A.

    2.2.1 Installing the point release on Server BAttentionInstalling Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool fromStart > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKSStart-Stop Services Control Panel tool to stop all services manually.

    To stop services1 Log on to the server using an account that is part of both the Windows Administrators and Product

    Administrators group.AttentionEnsure that you log on with the mentioned required privileges.

    2 Confirm that Server A is primary.3 If the servers are not synchronized, click Synchronize. The servers are synchronized.4 Continue with the following steps on Server B.5 Perform the following Checkpoint tasks.

    a Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.AttentionAny currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automaticor manual Checkpoint Save tasks are complete.

    b Ensure that the CPBASE and Checkpoint shares have replicated correctly between Server B and ServerA.

    c Ensure that the Checkpoint share has replicated correctly to all the Console stations.d To verify the CPBASE and the replication of the Checkpoint shares, check the Event Summary Display

    page on the Station after the manual/auto Checkpoint Saves are completed for all controllers. If theEvent Summary Display page does not display any replication failure event, the replication issuccessful.

    6 For systems with licensed QVCS only: Open the QVCS Manager application and complete the requiredQVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Managerapplication manually.

    7 Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recoveryservice (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.

    AttentionYou must enable the services after completing the procedure.

    8 Perform the following steps to disable ERDB replication.a Open Configuration Studio.b Select Administer Control Strategy Database. Perform the required steps to disable ERDB replication.

    9 Perform the following steps to disable EMDB replication.a Open Configuration Studio.b Select Administer the System Database. Perform the required steps to disable EMDB replication.

    2 EXPERION PKS R430.3 INSTALLATION

    27

  • 10 Close all the running applications.The installer automatically stops most of the required Experion services. However, certain services that arenot stopped by the installer must be stopped manually.Perform the following steps to manually stop Experion services.a Click Start > Programs > Honeywell > Experion PKS > Server > Start-Stop Experion PKS Server

    window.b Select Database Unloaded in Full mode.c Close the Start-Stop Experion PKS Server window.Perform the following steps to stop RSLinx for systems using ControlNet.a On the desktop, right-click My Computer and select Manage.

    The Computer Management window appears.b Expand Services and Applications in the left pane.c Click Services.

    The list of services appears in the right pane.d Perform the following steps.

    1. Right-click RSLinx Classic and select Stop.2. Right-click Harmony and select Stop.

    e Close the Computer Management window.

    To install the point Release To install, perform the following steps.

    a If you are using Experion Support and Maintenance (ESM) to install the point release, install the pointrelease from the ESM client. For more information, refer to the Installation Builder User's guide. If youare not using ESM to install the point release, go to step b.

    b Ensure that you are logged on using an account that is part of both the Windows Administrators andProduct Administrators group.

    c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKSR430.3 > supportsoftware.exe. If the installation is from the network then map the location where theinstaller folder is located to the network drive.

    Attention1. In the command prompt, as an Administrator, type the following command.

    net use : \\computername\share\ (for example, net use Z: \\199.63.5.151\temp\ExperionPKS R430.3 )Ensure that the path mapped (for example, \\199.63.5.151\temp\) has both Read andWrite permissions.

    2. Type the user name and password (must be in quotes if there is a blank).3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.

    d Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Controldialog box is displayed, click Yes to continue.The Welcome to Experion PKS Update Manager dialog box appears.

    e Click Install to start the Experion PKS R430.3 installation.

    2 EXPERION PKS R430.3 INSTALLATION

    28 www.honeywell.com

  • Attention During the installation, when the system restarts, manually log on to the system with the required

    credentials to continue with the installation. If the installation is being performed from the network, after each system restart, map the drive to continue

    the installation. To map the drive, perform the steps as given in the Attention of Step b. You may see the following error message related to service which cause the installation to abort. Stop the

    service manually after acknowledging the message and restart the installation.Failed to stop . Installation will be aborted now.

    f Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

    To validate the point release installation To verify if the Experion PKS R430.3 is installed, perform the following steps:

    a Using Notepad, open the ProductVersion.txt file located in the following path.C:\Program Files(X86)\Honeywell\Experion PKS OR \Honeywell\Experion PKS.

    b Verify the ProductVersion.txt for the following:+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PMIf the above line is present, it indicates that the installation is successful.

    NoteAfter Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that thesystem is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, youmay also see previous Experion release references in the product info.

    Post-installation tasks1 Log on as a member of Windows Administrators and Product Administrators group.2 Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.3 If the servers are not synchronized, click Synchronize. The servers are synchronized.4 Click Manual Failover. The server failover takes place.

    AttentionServer B becomes primary.

    5 Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recoveryservice (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must beenabled.

    To update Common Components packages (optional step)1 Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.

    AttentionNote that these steps must be performed ONLY if you install an optional common component package afterinstalling Experion PKS R430.3. The steps must be performed to update the installed optional common componentpackage version to Experion PKS R430.3 version.

    2 Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installerExperion PKS R430.3.

    3 Browse to the respective sub folder containing the common component packages folder.4 Choose Start > All Programs > Accessories > Command Prompt.5 Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.6 In the Command Prompt, enter the path of the common components update with the update name and click

    ENTER.

    2 EXPERION PKS R430.3 INSTALLATION

    29

  • 7 The common component update is installed. Updates to following common components are available. AppTPSBase Cl Server AppTPSClient AppTPSSolution Experion Remote Native Window Honeywell FTE MUX Driver Experion GUS Display Builder Experion GUS Display Runtime Experion GUS Remote displays Honeywell HCI Runtime Honeywell IKB Service Honeywell Redirection Manager Honeywell SafeView Honeywell Signon Manager Honeywell System Management Runtime Honeywell TPS Domain Console Configuration Honeywell File Transfer - Client Honeywell File Transfer - Server

    AttentionSUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It ismandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fixKB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install theMicrosoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://support2.microsoft.com/kb/2925489.

    2.2.2 Installing the point release on Server AAttentionInstalling Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool fromStart > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKSStart-Stop Services Control Panel tool to stop all services manually.

    To stop the services1 Log on to the server using an account that is part of both the Windows Administrators and Product

    Administrators group.AttentionEnsure that you log on with the mentioned required privileges.

    2 Confirm that Server B is primary.3 If the servers are not synchronized, click Synchronize. The servers are synchronized.4 Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery

    service (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.

    2 EXPERION PKS R430.3 INSTALLATION

    30 www.honeywell.com

  • AttentionYou must enable the services after completing the procedure.

    5 Turn off file replication of the mapping files .a In Station, click Configure > File Replication. Do not change the Send check box in this display.b Click mapping entry.

    The configuration page for mapping file replication entry appears.c Clear Replicate files from this path check box.d Click Save.

    6 Close all the running applications.The installer automatically stops most of the required Experion services. However, certain services that arenot stopped by the installer must be stopped manually.Perform the following steps to manually stop Experion services.a Click Start > Programs > Honeywell > Experion PKS > Server > Start-Stop Experion PKS Server

    window.b Select Database Unloaded in Full mode.c Close the Start-Stop Experion PKS Server window.

    7 Disable the Experion PKS Server System service. To disable the Experion PKS Server System service,perform the following steps.a Choose Start > All Programs > Accessories > Command Prompt.b Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.c In the Command Prompt, type the following command sc config HSCSERVER_System start= disabled

    and click ENTER (the command must have a space after the equal sign).d Ensure that you see the following message once the Experion PKS Server System service is disabled

    successfully [SC] ChangeServiceConfig SUCCESS.8 Perform the following steps to stop RSLinx for systems using ControlNet.

    a On the desktop, right-click My Computer and select Manage.The Computer Management window appears.

    b Expand Services and Applications in the left pane.c Click Services.

    The list of services appears in the right pane.d Perform the following steps.

    1. Right-click RSLinx Classic and select Stop.2. Right-click Harmony and select Stop.

    e Close the Computer Management window.

    To install the point Release To install, perform the following steps.

    a If you are using Experion Support and Maintenance (ESM) to install the point release, install the pointrelease from the ESM client. For more information, refer to the Installation Builder User's guide. If youare not using ESM to install the point release, go to step b.

    b Ensure that you are logged on using an account that is part of both the Windows Administrators andProduct Administrators group.

    c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKSR430.3 > supportsoftware.exe. If the installation is from the network then map the location where theinstaller folder is located to the network drive.

    2 EXPERION PKS R430.3 INSTALLATION

    31

  • Attention1. In the command prompt, as an Administrator, type the following command.

    net use : \\computername\share\ (for example, net use Z: \\199.63.5.151\temp\ExperionPKS R430.3 )Ensure that the path mapped (for example, \\199.63.5.151\temp\) has both Read andWrite permissions.

    2. Type the user name and password (must be in quotes if there is a blank).3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.

    d Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Controldialog box is displayed, click Yes to continue.The Welcome to Experion PKS Update Manager dialog box appears.

    e Click Install to start the Experion PKS R430.3 installation.Attention During the installation, when the system restarts, manually log on to the system with the required

    credentials to continue with the installation. If the installation is being performed from the network, after each system restart, map the drive to continue

    the installation. To map the drive, perform the steps as given in the Attention of Step b. You may see the following error message related to service which cause the installation to abort. Stop the

    service manually after acknowledging the message and restart the installation.Failed to stop . Installation will be aborted now.

    f Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.g Start the Experion PKS Server System service. To start the Experion PKS Server System service,

    perform the following steps.1. Choose Start > All Programs > Accessories > Command Prompt.2. Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to

    continue.3. In the Command Prompt, type the following command sc config HSCSERVER_System start= auto

    and click ENTER (the command must have a space after the equal sign).4. Ensure that you see the following message [SC] ChangeServiceConfig SUCCESS.5. In the Command Prompt, type the following command hscserver /start /y and click ENTER.6. Ensure that you see the following message once the Experion PKS Server System service is started

    successfully Starting Server.hsc_Server_Control_s -stateRequired=4 ...................hsc_Server_Control_s - Exiting, at end with returnval 4Completed successfully.

    To validate the point release installation To verify if the Experion PKS R430.3 is installed, perform the following steps:

    a Using Notepad, open the ProductVersion.txt file located in the following path.C:\Program Files(X86)\Honeywell\Experion PKS OR \Honeywell\Experion PKS.

    b Verify the ProductVersion.txt for the following:+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PMIf the above line is present, it indicates that the installation is successful.

    NoteAfter Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that thesystem is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, youmay also see previous Experion release references in the product info.

    2 EXPERION PKS R430.3 INSTALLATION

    32 www.honeywell.com

  • Post-installation tasks1 Log on as a member of Windows Administrators and Product Administrators group.2 Perform the following steps to enable ERDB replication.

    AttentionThis step must be performed from Server B.

    a Open Configuration Studio.b Select Administer Control Strategy Database. Perform the required steps to enable ERDB replication.

    3 Perform the following steps to enable EMDB replication.AttentionThis step must be performed from Server B.

    a Open Configuration Studio.b Select Administer the System Database. Perform the required steps to enable EMDB replication.

    4 Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.5 If the servers are not synchronized, click Synchronize. The servers are synchronized.6 Click Manual Failover. The server failover takes place.

    AttentionServer A becomes primary.

    7 If the servers are not synchronized, click Synchronize. The servers are synchronized.8 Turn on file replication of the mapping files .

    a In Station, click Configure > File Replication. Do not change Send check box in this display.b Click mapping entry.

    The configuration page for mapping file replication entry appears.c Select Replicate files from this path check box.d Click Save.

    9 Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recoveryservice (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must beenabled.

    10 Enable all the Checkpoint tasks.

    To update Common Components packages (optional step)1 Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.

    AttentionNote that these steps must be performed ONLY if you install an optional common component package afterinstalling Experion PKS R430.3. The steps must be performed to update the installed optional common componentpackage version to Experion PKS R430.3 version.

    2 Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installerExperion PKS R430.3.

    3 Browse to the respective sub folder containing the common component packages folder.4 Choose Start > All Programs > Accessories > Command Prompt.5 Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.6 In the Command Prompt, enter the path of the common components update with the update name and click

    ENTER.

    2 EXPERION PKS R430.3 INSTALLATION

    33

  • 7 The common component update is installed. Updates to following common components are available. AppTPSBase Cl Server AppTPSClient AppTPSSolution Experion Remote Native Window Honeywell FTE MUX Driver Experion GUS Display Builder Experion GUS Display Runtime Experion GUS Remote displays Honeywell HCI Runtime Honeywell IKB Service Honeywell Redirection Manager Honeywell SafeView Honeywell Signon Manager Honeywell System Management Runtime Honeywell TPS Domain Console Configuration Honeywell File Transfer - Client Honeywell File Transfer - Server

    AttentionSUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It ismandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fixKB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install theMicrosoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://support2.microsoft.com/kb/2925489.

    2 EXPERION PKS R430.3 INSTALLATION

    34 www.honeywell.com

  • 2.3 Installing the point release on Experion Application Server/ Console/Flex/Console Extension station/eServer/Premium Access clients

    AttentionInstalling Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool fromStart > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKSStart-Stop Services Control Panel tool to stop all services manually.

    To stop the services1 Log on to the server using an account that is part of both the Windows Administrators and Product

    Administrators group.AttentionEnsure that you log on with the mentioned required privileges.

    2 For systems with licensed QVCS only: Open the QVCS Manager application and complete the requiredQVCS operations (for example: Check in, Check out, revert, and so on). Close the QVCS Managerapplication manually.

    3 Perform the following Checkpoint tasks.a Disable all Checkpoint tasks; click Stop for all the scheduled Checkpoint tasks.

    AttentionAny currently executing Checkpoint tasks must be complete before continuing. Ensure that all the automaticor manual Checkpoint Save tasks are complete.

    b Ensure that the Checkpoint share has replicated correctly to all the Console stations.c To verify the replication of the Checkpoint shares, check the Event Summary Display page on the

    Station after the manual/auto Checkpoint Saves are completed for all controllers. If the EventSummary Display page does not display any replication failure event, the replication is successful.

    4 Disable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recoveryservice (Experion Backup and Restore) and the DVM Logger service, if present, must be disabled.

    AttentionYou must enable the services after completing the procedure.

    5 Close all the running applications.6 If RSLinx is installed, perform the following steps to stop RSLinx for systems using ControlNet.

    a On the desktop, right-click My Computer and select Manage.The Computer Management window appears.

    b Expand Services and Applications in the left pane.c Click Services.

    The list of services appears in the right pane.d Perform the following steps.

    1. Right-click RSLinx Classic and select Stop.2. Right-click Harmony and select Stop.

    e Close the Computer Management window.

    To install the point Release To install, perform the following steps.

    2 EXPERION PKS R430.3 INSTALLATION

    35

  • a If you are using Experion Support and Maintenance (ESM) to install the point release, install the pointrelease from the ESM client. For more information, refer to the Installation Builder User's guide. If youare not using ESM to install the point release, go to step b.

    b Ensure that you are logged on using an account that is part of both the Windows Administrators andProduct Administrators group.

    c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKSR430.3 > supportsoftware.exe. If the installation is from the network then map the location where theinstaller folder is located to the network drive.

    Attention1. In the command prompt, as an Administrator, type the following command.

    net use : \\computername\share\ (for example, net use Z: \\199.63.5.151\temp\ExperionPKS R430.3 )Ensure that the path mapped (for example, \\199.63.5.151\temp\) has both Read andWrite permissions.

    2. Type the user name and password (must be in quotes if there is a blank).3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.

    d Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Controldialog box is displayed, click Yes to continue.The Welcome to Experion PKS Update Manager dialog box appears.

    e Click Install to start the Experion PKS R430.3 installation.Attention During the installation, when the system restarts, manually log on to the system with the required

    credentials to continue with the installation. If the installation is being performed from the network, after each system restart, map the drive to continue

    the installation. To map the drive, perform the steps as given in the Attention of Step b. You may see the following error message related to service which cause the installation to abort. Stop the

    service manually after acknowledging the message and restart the installation.Failed to stop . Installation will be aborted now.

    f Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

    To install the point release on Premium Access clients Perform the following steps to install the point release on Premium Access clients.

    a Ensure that the eServer that is associated with the Premium Access client is already updated.b Log on to the server using an account with membership in the Local Administrators group and the

    Product Administrators group.c From the Start > Control Panel > Add or Remove Programs, select and remove the following

    programs. HMIWeb Browser Runtime Experion PKS Server Client Components

    d Open eServer home page and click on the link - Click here to install Premium Access components.e Click the appropriate link to install the Premium Access components.f Click the appropriate link to install the server client components.

    To validate the point release installation To verify if the Experion PKS R430.3 is installed, perform the following steps:

    a Using Notepad, open the ProductVersion.txt file located in the following path.C:\Program Files(X86)\Honeywell\Experion PKS OR \Honeywell\Experion PKS.

    2 EXPERION PKS R430.3 INSTALLATION

    36 www.honeywell.com

  • b Verify the ProductVersion.txt for the following:+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PMIf the above line is present, it indicates that the installation is successful.

    NoteAfter Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that thesystem is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, youmay also see previous Experion release references in the product info.

    Post-installation tasks1 Log on as a member of Windows Administrators and Product Administrators group.2 Click Start > All Programs > Honeywell Experion PKS > Server > Station to start the station.3 Enable all virus scan/protection/backup applications or services. Both the Symantec LiveState Recovery

    service (Experion Backup and Restore) and the DVM Logger service, if present and disabled, must beenabled.

    4 Enable all the Checkpoint tasks.

    To update Common Components packages (optional step)1 Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.

    AttentionNote that these steps must be performed ONLY if you install an optional common component package afterinstalling Experion PKS R430.3. The steps must be performed to update the installed optional common componentpackage version to Experion PKS R430.3 version.

    2 Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installerExperion PKS R430.3.

    3 Browse to the respective sub folder containing the common component packages folder.4 Choose Start > All Programs > Accessories > Command Prompt.5 Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.6 In the Command Prompt, enter the path of the common components update with the update name and click

    ENTER.7 The common component update is installed. Updates to following common components are available.

    AppTPSBase Cl Server AppTPSClient AppTPSSolution Experion Remote Native Window Honeywell FTE MUX Driver Experion GUS Display Builder Experion GUS Display Runtime Experion GUS Remote displays Honeywell HCI Runtime Honeywell IKB Service Honeywell Redirection Manager Honeywell SafeView Honeywell Signon Manager Honeywell System Management Runtime Honeywell TPS Domain Console Configuration

    2 EXPERION PKS R430.3 INSTALLATION

    37

  • Honeywell File Transfer - Client Honeywell File Transfer - Server

    AttentionSUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It ismandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fixKB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install theMicrosoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://support2.microsoft.com/kb/2925489.

    2 EXPERION PKS R430.3 INSTALLATION

    38 www.honeywell.com

  • 2.4 Installing the point release on ACE or SCEAttentionInstalling Experion PKS R430.3 from removable drives (CD, DVD, USB drives) is not supported.Before installing the point release, you must stop the SNMP services. If PMD is installed, use PDS Server tool fromStart > All Programs > PMD > Start Or Stop PDS Server and stop the PMD services. Use the Experion PKSStart-Stop Services Control Panel tool to stop all services manually.

    To stop the services1 Perform the following steps.

    AttentionPerform step a through step d on Control Builder from Server B (redundant server) or Experion server (non-redundant).

    a From Control Builder Monitoring view, right-click the node FB and select Upload.The Upload box is displayed.

    b Clear Upload Server Configuration Information check box and click Continue.The tuning constants are uploaded from the controller to the Monitoring view of ERDB.

    c Right-click the node FB and select Update to Project.The Update dialog box is displayed.

    d Click Continue to ensure that the updated tuning constants on the Monitoring view are updated into theProject view of the ERDB.

    e Perform a manual Checkpoint Save of the controller.f Ensure that the Checkpoint shares have replicated correctly between the server and all the Console

    stations.g To verify the replication of the Checkpoint shares, check the Event Summary Display page on the

    Station once the manual Checkpoint Save is completed for this controller. If the Event SummaryDisplay page does not display any replication failure event, the replication is successful.

    2 Modify the node FB CEESTATE to IDLE.3 Change the node FB ACE / SIM command to SHUTDOWN. For more information, refer to the Control

    Building Users Guide.4 Shutdown the node FB from the Control Builder.

    To install the point Release To install, perform the following steps.

    a If you are using Experion Support and Maintenance (ESM) to install the point release, install the pointrelease from the ESM client. For more information, refer to the Installation Builder User's guide. If youare not using ESM to install the point release, go to step b.

    b Ensure that you are logged on using an account that is part of both the Windows Administrators andProduct Administrators group.

    c Browse to the folder (downloaded and extracted in section 1.3.7) containing the installer Experion PKSR430.3 > supportsoftware.exe. If the installation is from the network then map the location where theinstaller folder is located to the network drive.

    2 EXPERION PKS R430.3 INSTALLATION

    39

  • Attention1. In the command prompt, as an Administrator, type the following command.

    net use : \\computername\share\ (for example, net use Z: \\199.63.5.151\temp\ExperionPKS R430.3 )Ensure that the path mapped (for example, \\199.63.5.151\temp\) has both Read andWrite permissions.

    2. Type the user name and password (must be in quotes if there is a blank).3. In the same command prompt window, change to the above mapped drive and run supportsoftware.exe.

    d Right-click supportsoftware.exe and then click Run as Administrator. If the User Account Controldialog box is displayed, click Yes to continue.The Welcome to Experion PKS Update Manager dialog box appears.

    e Click Install to start the Experion PKS R430.3 installation.Attention During the installation, when the system restarts, manually log on to the system with the required

    credentials to continue with the installation. If the installation is being performed from the network, after each system restart, map the drive to continue

    the installation. To map the drive, perform the steps as given in the Attention of Step b. You may see the following error message related to service which cause the installation to abort. Stop the

    service manually after acknowledging the message and restart the installation.Failed to stop . Installation will be aborted now.

    f Follow the on-screen instructions and click Finish. The node restarts after the installation is complete.

    To validate the point release installation To verify if the Experion PKS R430.3 is installed, perform the following steps:

    a Using Notepad, open the ProductVersion.txt file located in the following path.C:\Program Files(X86)\Honeywell\Experion PKS OR \Honeywell\Experion PKS.

    b Verify the ProductVersion.txt for the following:+Experion PKS R430.3 Install completed on MM/DD/YYYY HH:MM:SS AM/PMIf the above line is present, it indicates that the installation is successful.

    NoteAfter Experion PKS R430.3 point release is installed, an entry is made in the registry to indicate that thesystem is upgraded to Experion PKS R430.3. However, no other references are being updated. Hence, youmay also see previous Experion release references in the product info.

    Post-installation tasks1 Perform a Checkpoint Restore for the node and correct any errors that are observed during the Checkpoint

    Restore.2 From the Control Builder Monitoring view, perform a COLDSTART or WARMSTART of ACE-CEE and

    SCE-CEE as follows:a Open the ACE-CEE Configuration form.b Click WARMSTART/COLDSTART (as applicable) from the CEE Command. For more information

    about COLDSTART and WARMSTART, refer to the Control Building Users Guide.3 Perform a Checkpoint Save after the node is successfully started. The CMs/SCMs are made active (in case

    of a COLDSTART only). This ensures that the necessary runtime information and the correct executionstates of the CMs/SCMs is available in the latest .cp file of ACE node.

    2 EXPERION PKS R430.3 INSTALLATION

    40 www.honeywell.com

  • To update Common Components packages (optional step)1 Ensure that you are logged on as a member of Windows Administrators and Product Administrators group.

    AttentionNote that these steps must be performed ONLY if you install an optional common component package afterinstalling Experion PKS R430.3. The steps must be performed to update the installed optional common componentpackage version to Experion PKS R430.3 version.

    2 Browse to the folder (downloaded and extracted in section 1.3.7) containing the point release installerExperion PKS R430.3.

    3 Browse to the respective sub folder containing the common component packages folder.4 Choose Start > All Programs > Accessories > Command Prompt.5 Right-click Command Prompt and click Run as Administrator. Click Yes in the prompt to continue.6 In the Command Prompt, enter the path of the common components update with the update name and click

    ENTER.7 The common component update is installed. Updates to following common components are available.

    AppTPSBase Cl Server AppTPSClient AppTPSSolution Experion Remote Native Window Honeywell FTE MUX Driver Experion GUS Display Builder Experion GUS Display Runtime Experion GUS Remote displays Honeywell HCI Runtime Honeywell IKB Service Honeywell Redirection Manager Honeywell SafeView Honeywell Signon Manager Honeywell System Management Runtime Honeywell TPS Domain Console Configuration Honeywell File Transfer - Client Honeywell File Transfer - Server

    AttentionSUIT October-ISO is devised to install the hot fix KB2925489 automatically on Experion R430.3 nodes. It ismandatory for other users who do not use SUIT- ISO to deploy security updates, to manually install hot fixKB2925489 before installing Anti-Virus patches, on Experion R430.3 nodes. Download and install theMicrosoft Hotfix KB2925489 available on request basis from the Microsoft vendor- http://support2.microsoft.com/kb/2925489.

    2 EXPERION PKS R430.3 INSTALLATION

    41

  • 2.5 Migrating controllers

    Related topicsUpdating the firmware on page 42Firmware revision on page 42

    2.5.1 Updating the firmware1. Perform the upgrade readiness checks using the Upgrade Tool (UT).

    For more information about UT, refer to the Experion Migration Planning Guide and Upgrade Tool UsersGuide.

    2. Migrate the controllers and modules using the Controller Migration wizard (CMW).CMW can be used for both on-process and off-process migration in an automated way. NTools and CToolscan be used for manual firmware upgrade.For more information about CMW, refer to Controller Migration in the respective Scenario-specificmigration guide.

    2.5.2 Firmware revisionThe following table provides details about the firmware versions.Module Module number Firmware version FileC200E TC-PRS022 EXP430.1-92.120 cee50e.pcm

    cpmboote.pcmC300 Cx-PCNT01 EXP430.1-92.120 c300.lcf

    c300app2.pcmc300app2_20.pcmc300boot2.pcmc300boot2_20.pcm

    EHPM EC-THPM01 EXP430.1-92.120 ehpm.lcfehpmapp1.pcmehpmboot1.pcm

    EHB EC-EHB01 EXP430.1-92.120 ehb.lcfehbapp1.pcmehbboot1.pcm

    FIM TK-FFIF01 EXP430.1-92.120 fimboot.nvsfimboot.pcmfimrex.nvsfimrex.pcm

    FIM4 Cx-PFB401 EXP430.1-92.120 fim4.lcffim4app2.pcmfim4boot2.pcm

    2 EXPERION PKS R430.3 INSTALLATION

    42 www.honeywell.com

  • Module Module number Firmware version FileFIM8 Cx-PFB801 EXP430.1-92.120 fim8.lcf

    fim8app2.pcmfim8boot2.pcm

    FTEB TC-FTEB01 EXP430.1-92.120 ftebboot.nvsftebboot.pcmftebrex.nvsftebrex.pcm

    PGM2 Cx-IP0101 EXP430.1-92.120 pgm2.lcfpgm2app1.pcmpgm2boot1.pcm

    IOLIM TC-IOLI01 EXP430.1-92.120 iolimapp.nvsiolimapp.pcmiolimboot.nvsiolimboot.pcm

    2 EXPERION PKS R430.3 INSTALLATION

    43

  • 2 EXPERION PKS R430.3 INSTALLATION

    44 www.honeywell.com

  • 3 Experion PKS R430.3 removal

    AttentionUninstallation of Experion PKS R430.3 is not supported.Contact Honeywell TAC to uninstall Experion PKS R430.3.

    45

  • 3 EXPERION PKS R430.3 REMOVAL

    46 www.honeywell.com

  • 4 Notices

    TrademarksExperion, PlantScape, SafeBrowse, TotalPlant, and TDC 3000 are registered trademarks of HoneywellInternational, Inc.OneWireless is a trademark of Honeywell International, Inc.

    Other trademarksMicrosoft and SQL Server are either registered trademarks or trademarks of Microsoft Corporation in theUnited States and/or other countries.Trademarks that appear in this document are used only to the benefit of the trademark owner, with no intentionof trademark infringement.

    Third-party licensesThis product may contain or be derived from materials, including software, of third parties. The third partymaterials may be subject to licenses, notices, restrictions and obligations imposed by the licensor. The licenses,notices, restrictions and obligations, if any, may be found in the materials accompanying the product, in thedocuments or files accompanying such third party materials, in a file named third_party_licenses on the mediacontaining the product, or at http://www.honeywell.com/ps/thirdpartylicenses.

    47

  • 4.1 Documentation feedbackYou can find the most up-to-date documents on the