exproof lighting systems 2016
DESCRIPTION
TTAF Exproof Lighting Systems 2016TRANSCRIPT
EXPROOF LIGHTING SYSTEMS
2016 v1
TTAF Elektronik Ltd was founded in Turkey to prove cable assemblies, wiring harnesses, custom design interconnect solutions for military and civilian electronics as well as total system solutions for telecommunication applications including: wiring harnesses, cable assemblies, optical fibre, multi-branched, power, RF, moulded, electromechanical assemblies, racks, panels , control boxes and lighting systems. Servicing diverse customers worldwide from the state of the art 6,000 m2 manufacturing facilities in Istanbul , TTAF is now a global wire harness and cable assembly leader with in-house tool and die-making facility for injection and moulding capabilities. After more than 30 years in the connector marketplace, TTAF capitalised to create our wire harness and cable assembly services offering wiring harness assemblies using optimum grade wire and materials with the aid of cutting-edge machines to meet electronic industry norms. TTAF facilities are certified to meet the most demanding quality standards including ISO9001:2008, UL, CE, IPC / WHMA-A-620B, AS9100C and ISO 16949:2009.
TTAF is a 3P & ETL certified telecom system provider and a USB and HDMI certified cable assembly manufacturer.
About TTAF®
of TTAF
Join
Today!
The Expanding World
Shenzhen | CHINA
R&D Office
İstanbul | TÜRKİYE
Headquarters & Manufacturing
TTAF kablo gruplama ve bağlantı elemanları konusunda müşteriye özel ürün dizaynları ve farklı ihtiyaçlara yönelik çözümleriyle; hem Türkiye’de, hem dünya çapında güven ve beğeni kazanmış uzman bir kuruluştur. Konnektör alanında uzun yılların deneyimiyle 2003 yılında Beylikdüzü’nde 6,000 m2 kapalı alanda kablo grubu üretimine başlayan TTAF, ilk olarak kahverengi eşya sektörüne yan sanayi olarak hizmet vermiş, zaman içinde teknolojiye yapılan yatırımlarla, kazanılan bilgi, birikim ve vizyonla birlikte savunma sanayi , otomotiv, endüstriyel ve telekom sektörlerinin de ihtiyaçlarını karşılar hale gelmiştir.
TTAF fiber optikten güç ve RF bağlantılarına, plastik enjeksiyonlu kablolardan elektromekanik çözümlere, panellere, kontrol kutularına ve led aydınlatma çözümlerine uzanan geniş bir yelpazede komple sistem çözümleri sağlamakta ve an itibariyle 65 ülkeye ihracat yapmaktadır. ISO 9001:2008, IPC/WHMA-A-620B, UL, CE, AS9100C ve ISO 16949:2009 kalite belgelerine sahip olan TTAF; aynı zamanda 3P ve ETL sertifikalı bir Telekom sistem sağlayıcısı ve USB & HDMI organizasyonları tarafından onaylı bir üreticidir.
TTAF® Hakkında
WaterproofFIELD ASSEMBLY CONNECTOR SERIES
ART NO WPT-0303M15-NN/00
Voltage Rating 250 Volts AC
Current Rating 15 Amps maximum
Min Wire Size OD 6 mm
Max Wire Size OD 10 mm
Contact Resistance 10 mΩ
Insulation Structure 500 MΩ at 500 Volts DC
Temperature Rating -40 °C + 105 °C
IP Rating IP 68
Mould Material PA 66
Contact / Terminal Material Nickel plated brass
Seal Material EPDM 70Sh A
Number of Poles 3
Current Rating 15 Amps maximum
Voltage Rating 500 Volts AC
Durability Voltage 1500 Volts AC
TECHNICAL SPECIFICATIONS
Waterproof Field AssemblyJunction ‘T’ Connector
IP68
EXPROOF LIGHTING SYSTEMS
ttaf.com.tr
ART NO WPI-0302M15-NN/00
Voltage Rating 250 Volts AC
Current Rating 15 Amps maximum
Min Wire Size (OD) 6 mm
Max Wire Size (OD) 10 mm
Contact Resistance 10 mΩ
Insulation Structure 500 MΩ at 500 Volts DC
Temperature Rating -40 °C + 105 °C
IP Rating IP 68
Mould Material PA 66
Contact / Terminal Material Nickel plated brass
Seal Material EPDM 70 Sh A
Number of Poles 3
Current Rating 15 Amps maximum
Voltage Rating 500 Volts AC
Durability Voltage 1500 Volts AC
TECHNICAL SPECIFICATIONS
Waterproof Field AssemblyIn-line ‘I’ Connector
IP68
» Designed and manufactured for the oilfield, chemical, steel, power, port and petroleum industries. » Ideal for harsh environments with high levels of humidity and moisture. » Suitable for gas explosive environments to group IIA, IIB and IIC requirements. » Compliant with Zone 1, Zone2, Zone 21 and Zone 22 category areas. » Temperature class areas from T1 to T6.
APPLICATIONS
EXL-01 SERIESHIGH POWER EXPLOSIONPROOF LED FLOODLIGHT
» Dual cable inlet system allowing for luminaries to be mounted in parallel or series configurations. » Employs the highest specification industry recognised components, such as Cree LED light
engines combined with a Mean-Well power supply. (PSU / driver) » Isolated LED chip-and-lens design improves thermal conductivity and ensures a market-leading
product lifespan. » Dual purpose. This unit can function as either a high bay or floodlight dependent on installation
and lens specification. » In-built heat sink balances unit efficiency with extreme structural integrity.
PRODUCT FEATURES
EXPROOF LIGHTING SYSTEMS
LED -40°C+50°CIP66
ttaf.com.tr
ART NO EXL-01050U EXL-01075U EXL-01100U EXL-01120U
LED Device Cree Cree Cree Cree
Lumen Output 4,925 lm (+/-5%) 6,015 lm (+/-5%) 9,195 lm (+/-5%) 11,440 lm (+/-5%)
Nominal Power Rating 50 Watts 75 Watts 96,5 Watts 120 Watts
Efficiency 98,5 lm / W 80,2 lm / W 95,3 lm / W 95,3 lm / W
Beam Angle (W/H) 90°(Standard), 60°, 120/140° 90°(Standard), 60°, 120/140° 90°(Standard), 60°, 120/140° 90°(Standard), 60°, 120/140°
Colour Temperature 5,000° Kelvin 5,000° Kelvin 5,000° Kelvin 5,000° Kelvin
Colour Rendering Index (CRI) > 80 Ra > 80 Ra > 80 Ra > 80 Ra
Lumen Maintenance L70 > 50,000 Hours L70 > 50,000 Hours L70 > 50,000 Hours L70 > 50,000 Hours
Input Voltage 90-305 Volts AC 90-305 Volts AC 90-305 Volts AC 90-305 Volts AC
Power Factor > 0.95 > 0.95 > 0.95 > 0.95
Input Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Anti Corrosion Grade WF2 WF2 WF2 WF2
Insulation Grade I I I I
Cable Diameter 8-14 mm 8-14 mm 8-14 mm 8-14 mm
Screw Thread G3/4” G3/4” G3/4” G3/4”
ENVIRONMENTAL
IP Rating IP66 IP66 IP66 IP66
Operational Temperature -40° to 50 °C -40° to 50 °C -40° to 50 °C -40° to 50 °C
Operational Humidity 0% to 90% RH 0% to 90% RH 0% to 90% RH 0% to 90% RH
PHYSICAL
Dimensions (φ x H) 300 x 332 x 202 mm 300 x 332 x 202 mm 300 x 332 x 202 mm 300 x 332 x 202 mm
Weight 6.3 kg 6.3 kg 6.3 kg 6.3 kg
WARRANTY
Details 5 Years comprehensive 5 Years comprehensive 5 Years comprehensive 5 Years comprehensive
TECHNICAL SPECIFICATIONS
Zone 1Gas class: IICTemperature Class: T6
EX II 2 GD*
» Designed and manufactured for the oilfield, chemical, steel, power, port and petroleum industries. » Ideal for harsh environments with high levels of humidity and moisture. » Suitable for gas explosive environments to group IIA and IIB requirements. » Compliant with Zone 1, Zone2, Zone 21 and Zone 22 category areas. » Temperature class areas from T1 to T6.
APPLICATIONS
EXL-02 SERIESEXPLOSION PROOFLED FLOODLIGHT
» Dual cable inlet system allows that the fixtures can be installed in parallel or series configurations. » Employs the highest specification industry recognised components, including Cree LED light
engines combined with a Mean-Well power supply unit. (PSU / driver) » Isolated LED chip-and-lens design improves thermal conductivity and ensures a market-leading
fixture lifespan and durability. » Multi-purpose, fit-and-forget technology for ultimate application flexibility and longevity. » In-built heat sink balances luminaire efficiency with extreme structural integrity.
PRODUCT FEATURES
EXPROOF LIGHTING SYSTEMS
ttaf.com.tr
ART NO EXL-02030U EXL-02040U EXL-02060U EXL-02075ULED Devices Cree Cree Cree Cree
Lumen Output 2,660 lm (+/-5%) 3,820 lm (+/-5%) 5,260 lm (+/-5%) 6,010 lm (+/-5%)
Nominal Power Rating 30 Watts 40 Watts 60 Watts 75 Watts
Efficiency 88,7 lm / W 95,5 lm / W 87,7 lm / W 80,1 lm / W
Beam Angle (W/H) 140 / 100° 140 / 100° 140 / 100° 140 / 100°
Colour Temperature 5,000° Kelvin 5,000° Kelvin 5,000° Kelvin 5,000° Kelvin
Colour Rendering Index (CRI) > 80 Ra > 80 Ra > 80 Ra > 80 Ra
Lumen Maintenance L70 > 100,000 Hours L70 > 100,000 Hours L70 > 100,000 Hours L70 > 100,000 Hours
Input Voltage 90-305 Volts AC 90-305 Volts AC 90-305 Volts AC 90-305 Volts AC
Power Factor > 0.98 > 0.98 > 0.98 > 0.98
Input Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Anti Corrosion Grade WF2 WF2 WF2 WF2
Insulation Grade I I I I
Cable Diameter (OD) 8-14 mm 8-14 mm 8-14 mm 8-14 mm
Screw Thread G3/4” G3/4” G3/4” G3/4”
ENVIRONMENTAL
IP Rating IP66 IP66 IP66 IP66
Operational Temperature -40° to 50 °C -40° to 50 °C -40° to 50 °C -40° to 50 °C
Operational Humidity 0% to 90% RH 0% to 90% RH 0% to 90% RH 0% to 90% RH
PHYSICAL
Dimensions (φ x H) 370 x 326 x 88 mm 370 x 326 x 88 mm 370 x 326 x 88 mm 370 x 326 x 88 mm
Weight 6.5 kg 6.5 kg 6.5 kg 6.5 kg
WARRANTY
Details 5 Years comprehensive 5 Years comprehensive 5 Years comprehensive 5 Years comprehensive
TECHNICAL SPECIFICATIONS
LED -40°C+50°CIP66
Zone 1Gas class: IICTemperature Class: T6
EX II 2 GD*
» Designed and approved for safe use in explosive environments such as underground in coal mining where dangerous levels of methane and explosive dust exist.
» The idea lighting fixture solution for the underground working in tunnels or tunnel construction.
APPLICATIONS
EXL-03 SERIESEXPLOSION PROOFPENDANT LUMINAIRE
» Dual cable inlet system allows that the fixtures can be installed in parallel or series configurations. » Employs the highest specification industry recognised components, including Cree LED light
engines combined with a Mean-Well power supply unit. (PSU / driver) » Isolated LED chip-and-lens design improves thermal conductivity and ensures a market-leading
fixture lifespan and durability. » Multi-purpose, fit-and-forget technology for ultimate application flexibility and longevity. » In-built heat sink balances luminaire efficiency with extreme structural integrity.
PRODUCT FEATURES
EXPROOF LIGHTING SYSTEMS
ttaf.com.tr
ART NO EXL-03060U
LED Devices Cree
Lumen Output 5,230 lm (+/-5%)
Nominal Power Rating 60 Watts
Efficiency 87.2 lm / W
Beam Angle (W/H) 220°
Colour Temperature 5,000° Kelvin
Colour Rendering Index (CRI) > 80 Ra
Lumen Maintenance L70 > 100,000 Hours
Input Voltage 90-264 Volts AC
Power Factor > 0.95
Input Frequency 50 / 60Hz
Anti Corrosion Grade WF2
Insulation Grade I
Cable Diameter (OD) 8-14 mm
Screw Thread G3/4”
ENVIRONMENTAL
IP Rating IP66
Operational Temperature -40° to 50 °C
Operational Humidity 0% to 90% RH
PHYSICAL
Dimensions (φ x H) 240 x 234 mm
Weight 5.0 kg
WARRANTY
Details 5 Years comprehensive
TECHNICAL SPECIFICATIONS
Zone 1Gas class: IICTemperature Class: T6
LED -40°C+50°CIP66
EX II 2 GD*
» Provides operators with a powerful and energy efficient spotlight for use in flammable environments such as coal mines, indoor and outdoor work and/or monitoring tasks.
APPLICATIONS
EXL-O4 SERIESEXPLOSION PROOF MINING SPOTLIGHT
» Dual cable inlet system allows that the fixtures can be installed in parallel or series configurations. » Employs the highest specification industry recognised components, including Cree LED light
engines combined with a Mean-Well power supply unit. (PSU/driver) » Isolated LED chip-and-lens design improves thermal conductivity and ensures a market-leading
fixture lifespan and durability. » Multi-purpose, fit-and-forget technology for ultimate application flexibility and longevity. » In-built heat sink balances luminaire efficiency with extreme structural integrity.
PRODUCT FEATURES
EXPROOF LIGHTING SYSTEMS
ttaf.com.tr
LED -40°C+50°CIP66
ART NO EXL-04060U
LED Devices Cree
Lumen Output 5,500 lm / W (+/-5%)
Nominal Power Rating 60 Watts
Efficiency 91.7 lm / W
Beam Angle (W/H) 25° (45°-60°)
Colour Temperature 5,000° Kelvin
Colour Rendering Index (CRI) > 80 Ra
Lumen Maintenance L70 > 100,000 hours
Input Voltage 90-264 Volts AC
Power Factor > 0.95
Input Frequency 50 / 60Hz
Anti Corrosion Grade WF2
Insulation Grade I
Cable Diameter 8-14 mm
Screw Thread G3/4”
ENVIRONMENTAL
IP Rating IP66
Operational Temperature -40° to 50 °C
Operational Humidity 0% to 90% RH
PHYSICAL
Dimensions (φ x H) 180 x 243 mm
Weight 3.8 kg
WARRANTY
Details 5 Years comprehensive
TECHNICAL SPECIFICATIONS
Zone 1Gas class: IICTemperature Class: T6
EX II 2 GD*
» Designed and manufactured for widespread uses within the petroleum, chemical, transport, aerospace, aviation, military, processing and other industries.
» Ideal for harsh environments with high levels of humidity and moisture. » Suitable for gas explosive environments to group IIA, IIB and IIC requirements. » Compliant with Zone 1, Zone2, Zone 21 and Zone 22 category areas. » Temperature class areas from T1 to T6.
APPLICATIONS
EXL-05 SERIESEXPLOSION PROOF LINEAR LED LUMINAIRE
» Dual cable inlet system allows that the fixtures can be installed in parallel or series configurations. » Employs the highest specification industry recognised components, including Cree LED light engines
combined with a Mean-Well power supply unit. (PSU / driver) » Isolated LED chip-and-lens design improves thermal conductivity and ensures a market-leading
fixture lifespan and durability. » Multi-purpose, fit-and-forget technology for ultimate application flexibility and longevity. » In-built heat sink balances luminaire efficiency with extreme structural integrity.
PRODUCT FEATURES
EXPROOF LIGHTING SYSTEMS
ttaf.com.tr
LED -40°C+45°CIP66
ART NO EXL-05040U
LED Devices Cree
Lumen Output 2,590 lm (+/-5%)
Nominal Power Rating 40 Watts
Efficiency 65 lm / W
Beam Angle (W/H) 25° (45° - 60°)
Colour Temperature 5, 500° Kelvin
Colour Rendering Index (CRI) > 70 Ra
Lumen Maintenance L70 > 50,000 Hours
Input Voltage 90-264 Volts AC
Power Factor > 0.95
Input Frequency 50 / 60 Hz
Anti Corrosion Grade WF2
Insulation Grade I
Cable Diameter 8-14 mm
Screw Thread G3/4”
ENVIRONMENTAL
IP Rating IP66
Operational Temperature -40° to 45 °C
Operational Humidity 0% to 90% RH
PHYSICAL
Dimensions (φ x H) 1370 x 215 x 110 mm
Weight 12 kg
WARRANTY
Details 5 Years comprehensive
TECHNICAL SPECIFICATIONS
Zone 1Gas class: IICTemperature Class: T6
EX II 2 GD*
HEADQUARTERS & MANUFACTURING FACILITY Kavaklı Mah İstanbul Cad. No:21 Beylikdüzü İstanbul / TÜRKİYE - Tel +90 212 855 82 20 | Fax +90 212 855 82 21