Extending the Capabilities of Ablation Harmonics to Shorter Wavelengths and Higher Intensity Extending the Capabilities of Ablation Harmonics to Shorter Wavelengths and Higher Intensity T. Ozaki, L. Elouga Bom, R. A. Ganeev, J.-C. Kieffer INRS - EMT, Univ. Québec T. Ozaki, L. Elouga Bom, R. A. Ganeev, J.-C. Kieffer INRS - EMT, Univ. Québec

Upload: others

Post on 10-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Extending the Capabilities of

    Ablation Harmonics to Shorter Wavelengths and

    Higher Intensity

    Extending the Capabilities of

    Ablation Harmonics to Shorter Wavelengths and

    Higher Intensity

    T. Ozaki, L. Elouga Bom, R. A. Ganeev, J.-C. Kieffer

    INRS - EMT, Univ. Québec

    T. Ozaki, L. Elouga Bom, R. A. Ganeev, J.-C. Kieffer

    INRS - EMT, Univ. Québec

  • OutlineAblation Harmonics: A highly efficient method for harmonic generationSilver Harmonics: Intense sources in the plateauQuasi-monochromatic, intense harmonics using indium and tin ablationManganese Harmonics: Extending harmonics to shorter wavelengths

  • Gas Jet

    High-IntensityUltrashort Pulse Laser

    Harmonics

    High-Order HarmonicsCoherent soft x-ray beams (odd multiple orders of pump) Low-divergence (~ mrad)Ultrashort pulse (femtosecond, and even attosecond)Harmonic orders > 500, photon energy > 1000 eV, observed

    Low conversion efficiency (~10-6 to 10-7)

  • Femtosecond diffractive imaging with a soft-X-ray free-electron

    laserChapman et al., Nature Physics 2, 839 (2006)

    6 μJ, 32 nm FEL

    Φ20 μm4×1013 W cm-

    2

    1 μm

    Spatial resolution: 62 nm

    Spatial resolution: 62 nm

  • Ablation Harmonics

    Harmonics

    A New Method to Generate IntenseHarmonicsThe Idea ... use dense laser-ablation media as the

    nonlinear medium

    CCD

    MCPHitachiGrating(1200 l /mm)

    Soft X-ray Spectrometer

    Pump Pulse40 mJ, 30~150

    fs

    SolidTarget

    Prepulse~10 mJ, 200

    ps

    Setup at ALLSTwo-beam, 100 mJ, 25 fs

    outputs•Independent control of energy of the two beams

  • Ablation Harmonics are Highly Efficient

    High conversion efficiency of 10-5 demonstrated in the plateau (13th

    ~ 31st)

    Sub-μJ harmonics already obtained with 10 mJ pumpMulti- μJ harmonics envisaged with full use of ALLS 150 mJ pump

    10-9

    10-8

    10-7

    10-6

    10-5

    10-4

    300 350 400 450

    Wavelength (nm)

    40 50 60

    Boron

    Silver

    (Silver)

  • Ag Ablation Harmonic Intensityas a function of Main Pump

    Intensity

    1200

    800

    400

    0Har

    mon

    ic In

    tens

    ity [a

    rb.u

    nits

    ]

    35302520151050

    Main Pulse Intensity [1014 W cm-2]

    17th 25th 35th 47th

    10-5 conversionefficiency

    10-5 conversionefficiency

  • Prepulse Intensity has large effects on Ablation Harmonics

    2000

    1500

    1000

    500

    0

    Har

    mon

    ic In

    tens

    ity [a

    rb.u

    nits

    ]

    3.02.01.00

    Prepulse Intensity [1010 W cm-2]

    17th 25th 35th 47th

  • Higher Prepulse Intensity results in Higher Ion Density

    6

    5

    4

    3

    2

    1

    0

    Ion

    Den

    sity

    [101

    7 cm

    -3]

    3.02.01.00.0

    Prepulse Intensity [1010 W cm-2]

    2.0

    1.5

    1.0

    0.5

    0.0

    Ionization Level

    300 µm from target surface

  • Preplasma Condition Needs to be Controlled

    CarefullyGold Harmonics

    HHG Positive HHG Negative

  • Intense Quasi-monochromatic Harmonics from Indium

    Ablation

    Intense Quasi-monochromatic Harmonics from Indium

    Ablation

    2 0 3 0 6 0 7 05 04 0

    1 0 - 5

    1 0 - 6

    1 0- 7

    W a v e l e n g th ( n m )

    1 1 t h

    1 3 t h

    1 5t h

    1 7t h

    1 9 t h2 1s t2 3

    r d2 5 t h

    2 7 t h

    2 9t h

    3 1s t

    (61.2 nm)

    Indium

    • Conversion efficiency close to 10-4

    • Energy of 13th harmonic near 1μJ

    • 10 μJ harmonics possible with ALLS

    All harmonics disappear with elliptical polarization pump

  • Other Quasi-Monochromatic Harmonics

    2) Chromiun (Cr) Intense 29 H, λ=27.58 nmIntense 29 H, λ=27.58 nm

    3) Manganese (Mn) Intense 17 H, λ=23.5 nmIntense 17 H, λ=23.5 nm

    800 nm pump

    400 nm pump

    1) Tin (Sn) Intense 17 H, λ=47.05 nmIntense 17 H, λ=47.05 nm

    Sn II4d10 5s2 5p P3/2

    - 4d9 5s2 5p2 (1D) 2D5/2

  • Spec

    tral

    Inte

    nsity

    [arb

    .uni

    ts]

    323028262422201816

    Energy [eV]

    796 nm

    782 nm

    770 nm

    Plasma

    Comparison of Harmonic Spectra with Emission from Over-ionized

    Plasma

    Calculated synthetic spectra to (a) In II 5s2 ground state, and (b) In II

    5s5p state

    Ref.: G. Duffy & P. Dunne, J. Phys. B 34, L173 (2001)

    13th

    15th

    4d105s2 1S0 → 4d95s25p(2D) 1P2(19.92 eV) : gf = 1.11

  • Improved Phase Matching due to Anomalous

    DispersionPhase-matching condition for qth harmonic

    Ne(a): electron (atom) density; re: classical electron radius; λqω: wavelength of qth harmonic; δ: neutral atom dispersion

    Idea: use anomalous dispersion near strong resonances to compensate for increased phase mis-

    match due to Ne

    C. Dölle et al., Appl. Phys. B 75, 628-634

    ... already demonstrated for third harmonic of KrF

    laser in Ar

  • Going to Shorter Wavelengths

    Extending the Cut-off with Manganese

    30mJ

    45mJ

    38mJ

    101H

    Largest cut-off (101th order, λ = 7.9nm) ever observed with this methodTwo plateaus

    Largest cut-off (101th order, λ = 7.9nm) ever observed with this methodTwo plateaus

    19mJ

    33H25HEmp

  • What makes Manganese Different ?

    Ip 1st

    [eV]2nd[eV]

    3rd[eV]

    Mn 7.4315.64

    33.67

    Au 9.2220.52

    30.05

    Mn: 3.25 x1017 cm-3

    Au: 14.2 x1017 cm-3Mn: 3.25 x1017 cm-3

    Au: 14.2 x1017 cm-3

    Electron density of Ablation

    (Ipp = 2 x1010 W/cm2)Simulated by HYADES

    Ionization potential... not that different

    Under the same prepulse condition, the electron density for Mn is unusually low

    ... reduced negative effects of free electrons

  • ConclusionsAblation harmonics: Intense sources of high-order harmonic generationSilver harmonics: intense sources in the plateau

    Quasi-monochromatic harmonics: intense, single-line harmonics

    Manganese harmonics: One step toward shorter wavelength harmonicsLow electron density of ablation medium

    Text2: Proceedings of the 3rd International Conference on the Frontiers of Plasma Physics and Technology (PC/5099)Text3: S2-4