Extension for "KZE3-XS" safety relay (22.5 mm)
Extending the number of contacts in a safety relay Used to increase the breaking capacity of the main unit "CE" conforming product / BG approved Safety via redundancy and self-checking 3 "N/O" safety contacts with linked contacts -
6 A / 250 Vaa
1 "N/C" return loop
1Power supplyPower supply voltage
Operating range
On/off indication
AccuracySynchronisation differenceMaximum response time onemergency stop at Un Output specificationTypeNo. of safety circuits Return loopBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
< 25 ms50 ms
Volt-free outputs 3 "N/O" AgSnO2 contacts1 "N/C" AgSnO2 contact1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.6 VA / DC 2 W 1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.42 kV when coupled10 V/m Level 3 acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)8 kV in the air acc. to IEC 1000.4.2Common mode 1 kV according toIEC1000.4.510 V rms Level 3 acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor310 g
Technical characteristics
EMC immunity according to EN 50082-2
Standard products
To order, specify :
Part number
Example : Extension for KZE3-XS safety relay :85 100 936
1
TypePart number (and voltage)
24 V a/c40/260 V a
ConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41NF-EN 60204-1NF-EN 292-1 and 2NF-EN 954-1NF-EN 418NF-EN 1088UL 508C22-2 No. 14-M91GS-ET-20
*Available 2nd half 1999
Connections
KZE3-XS
85 100 936
* 85 100 937
UL (C) UL BG
Key
A1-A2 : Power supply Control device(s)
41 - 42 : Return contact13-14/23-24/33-34 : "N/O" safety contactsX1-X2 : Internal return loop
Example of wiring
24 V
0V
13 23KZE3-XSKNA3-XS
33
14 24 34
A1 X1 X22313 33
14 24 3441A2 42
13 23 33
14 24 34
A1 Y1 Y22313 33
14 24 3441A2 42
C4C3 C5 C6C2C1
c2
c1
Emergencystop
X1-X2 of theKZE3-XSbridged
Start
KZE3-XS controlled by a singlechannel as an extension of a KNA3-XS
13 23 33
A1 X1 X 2
13 23 33 41
14 24 41 42
A2 41 42
2414 34
KZE3-XS
OUT
PWR
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/21
11
Examples of use
Control devices :
Depending on the degree of safety required, the KZE3-XS can becontrolled by one or two channels. In most cases, control by one channelwill be sufficient. Please consult your inspection office for furtherinformation.
Control devices :
The KZE3-XS has three "N/O" safety contacts (13-14/23-24/33-34) and a return loop (X1-X2) which must be included in the "start /
validation" line (Y1-Y2) of the main unit. One or more control devices maybe wired up to the breaking capacity of the safety contacts : 1500 VA.However, to limit internal heating in the KZE3-XS, it is advisable not toexceed 10 A thermal for all three contacts.
Extending the number of contacts :
It is possible to wire several extension KZE3-XS units in cascade. All thereturn loops (X1-X2) will be in series with the "start / validation" line (Y1-Y2) of the main unit.
Dimensions Mounting - Removing see page 11/7
24 V
0V
13 23KZE3-XSKNA3-XS
33
14 24 34
A1 X1 X22313 33
14 24 3441A2 42
13 23 33
14 24 34
A1 Y1 Y22313 33
14 24 3441A2 42
13 23KZE3-XS
33
14 24 34
A1 X1 X22313 33
14 24 3441A2 42
C4C3 C5 C8C7 C9C6C2C1
c2
c1
+ 24 V
0V
Y11A1
KNA3-RS
X1 Y2 51 52 4123Y12 3313
A2 Y21Y22Y1X2 14 24 34
42
13 23 33 41
14 24 34 42
13 23KZE3-XS
33
14 24 34
A1 X1 X22313 33
14 24 3441A2 42
C4C3 C5C1 C2
c3
c2
c1
c4
c5
Emergencystop
Start
Emergencystop
Two KZE3-XS as extensions of a KNA3-XS KNA3-RS with KZE3-XS extension unit
90
22,5
90
113
68,6
118 +0,5–0
Start
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/14
11
"KSW2-RS" safety relay (45 mm)
"Zero speed monitoring" function for a single or 3-phase motor Detection of actual stopping by measuring remanent voltages "CE" conforming product / BG approved Safety via redundancy and self-checking Wiring integrity check Galvanic isolation 1 "N/O" safety contact with linked contacts - 6 A / 250 Vaa
1 "N/C" safety contact with linked contacts - 6 A / 250 Vaa
Separate return loop Can be used to obtain level 4 according to NF.EN 954-1
13 21
A1 X1
13 21
14 22
X2
A2 L1
2214 L2 L3
KSW2-RS
OUT
PWR
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeSetting for channels 1 and 2Synchronisation differenceHysteresisOutput specificationTypeNo. of safety circuits Breaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
3 s (self-test)From 20 mV to 500 mV +/- 15% < 3 s40% +/- 50%
Volt-free outputs 1 "N/O" + 1 "N/C" AgSnO2 contact1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.6 VA / DC 2 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.42 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 2 kV for 24 Vc
and 24 Va
30 V rms Level X acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor410 g
Technical characteristics
EMC immunity according to EN 50082-2
Standard products
To order, specify :
Part number
Example : KSW2-RS safety relay : 85 100 326
1
TypePart number (and voltage)
24 V a/cConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41IEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
KSW2-RS
85 100 326
Category 4
UL (C) UL BG
Key
A1-A2 : Power supplyX1-X2 : Return loopL1-L2 : Input channel 1 (motor winding)L2-L3 : Input channel 2 (motor winding)13-14 : "N/O" safety contacts21-22 : "N/C" safety contacts
1
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/15
11
Examples of use
Self-test :
When terminals A1-A2 are powered up, a test sequence is initiated : theoutput relays (terminals 13-14 and 21-22) are energised for 1.5 s thenseparate for 1.5 s. If no fault is detected, the relays reattach. This testchecks :- failure of the output contacts (terminals 13-14 and 21-22)- breaking of one of the phases (L1, L2 or L3)- the validity of the return loop (X1-X2)- the failure of an internal component
Safety function :
When an electric motor rotates while no longer supplied with power, itbehaves like a generator, supplying voltage (called remanent) to theterminals of its windings. This voltage varies according to severalparameters : speed of rotation, the motor characteristics, remanentmagnetisation, inertia of the mechanical assembly. The KSW2-RSmeasures this voltage and interprets it so that the doors and mobileguards can only be opened once the motor has actually stopped.
Dimensions Mounting - Removing see page 11/7
Y11A1
+ 24 V
0V
13
KZH3-RS
23 33 41
14 24 34 42
X1 Y2 S1 S2 4123Y12 3313
A2X2
Y12Y22
Y1 14 24 34Y21Y22 42
Y2
Y1
Y12Y22
C1
C2
M
13A1
KSW2-RS
X1 X221
A22214 L2 L3
L1L2L3
L1
C1
c1
c2
C2
Setting :
Both channels are set on the front of the KSW2-RS using twopotentiometers. This mitigates the effects of any imbalance between thewindings or remanent voltages. Setting is within a range of 20 mV to 500 mVin order to adapt a threshold to a slow or zero speed, which is notdangerous for the operator.
Control devices :
The KSW2-RS has one "N/O" (13-14) and one "N/C" (21-22) safety contact.One or more control devices may be wired up to the breaking capacity of thesafety contacts : 1500 VA.
Extending the number of contacts :
The number of contacts of the KSW2-XS can be extended and the breakingcapacity thus increased. To do this, use the KZE3-XS (see page 11/20).
OP
EN
ING
Start
Emergencystop
Opening
Indicator lit ifmotor running
90
45
90
113
68,6
118 +0,5–0
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/22
11
“Relevelling zone check” functions conforming to EN 81 "CE" conforming product with type-examination BG approved product Control device with two channels Safety via redundancy and self-checking Integrity check on control devices 2 "N/O" safety contacts with linked contacts - 6 A / 250 aa 1 “N/C” signalling contact - 1 A Can be used to obtain level 4 according to NF.EN 954-1
"KZHNV-XS" safety relay (22.5 mm)
To order, specify :
Technical characteristicsPower supplyPower supply voltage a 24 V 50/60 Hz
c 24 V max. ripple 10 %Operating range – 15 % / + 10 % of Un for a
– 15 % / + 15 % of Un for cOn/off indication 1 power supply voltage LED
AccuracySynchronisation difference < 500 msResponse time on release < 50 msof control deviceOutput specificationType Volt-free outputs No. of safety circuits 3 "NO" AgSnO2, contacts No. of data circuits 1 "N/C" AgSnO2, contactsBreaking capacity 1500 VA resistiveMax. current breaking capacity 6.82 AMax. voltage breaking capacity 440 VACElectrical life 105 operations at 1500 VA resistive
5.105 operations at 500 VA resistiveMechanical life 107 operationsOperation and useMax. absorbed power at UN 1.5 VA - 24 VAC / 1.5 W - 24 VDCOn/off indication 1 internal relay status LEDOperating temperature 0°C to + 50°C acc. to IEC 68-2-14Storage temperature – 20°C to + 70°C acc. to IEC CEI 68-1/2Internal voltage 24 V cEMC immunity according to EN 50082-2Rapid transients 2 kV directly acc. to IEC 1000.4.4
2 kV when coupledRadiated electromagnetic field 30 V/m level 3 acc. to IEC 1000.4.3
80 Mhz to 1 GHz / 900 MHz(ENV 50140/204)
Electrostatic discharges 15 kV in the air acc. to IEC 1000.4.2Shock waves Level 3 according to IEC 1000.4.5
Common mode 2 kV according to24 V c and 24 V a
Radio frequencies 10 V RMS on inputs /in common mode Level 3 acc. to IEC 1000.4.6
30 V RMS on power supply Level X acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11
Drop-out / short breaks / Un-30 % for 10 ms every 1 smicrobreaks Un-60 % for 100 ms every 1 s
according to IEC 61496-1/97Un-100 % for10 msevery 100 ms*Un-50 % for 20 msevery 200 ms*Un-50 % for 500 msevery 5 s**
Dielectric strength 2.95 kV according to IEC 664-1Resistance to tracking Material group IIICasingMaterial Polycarbonate
Self-extinguishing - UL94 class VODegree of protection Casing : IP40
Terminal : IP20Terminal capacity 2 x 1.5 mm2 multicore with ferrule
2 x 2.5 mm2 solid conductorWeight 230 g
Standard products Part number
Example : Safety relay KZHNV-XS : 85 100 526
1
Type KZHNV-XSPart number (and voltage)24 V a c 85 100 526
ConformityEuropean "Machinery" Directive 98/37/EEC
French Decree 92/765-766-768
European "Usage" Directive 89/655/EEC
French Decree 93/40 / 93-41
European “Usage” Directive "EMC" 89 336/EEC
IEC 61496-1
IEC 664-1
EN 50081-2
EN 50082-2
EN 60204-1
EN 292-1 and 2
EN 954-1 Category 4EN 81
EN 418
EN 1088
UL 508 ULC22-2 N° 14-M91 (C) ULGS-ET-20 BG** the device operates normally** the device has not failed dangerously
Connections
KeyA1-A2 : Power supplyY11-Y12 and Y21-Y22 : Redundant inputs with differentiated voltage
for control devices13-14/23-24 : "NO" safety contacts41-42 : "N/C" signalling contacts
13 23 41
A1 Y11 Y12
PWR
OUT
13 23 41
1+ Z+ +Z
KZHNV-XS
A2 Y21 Y22
14 24 42
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/23
11
Dimensions Mounting - Removing
13 23 41
A1 Y11 Y12
PWR
OUT
13 23 41
1+ Z+ +Z
KZHNV-XS
A2 Y21 Y22
14 24 42
Enable
Check state of safety relay
ELECTRONICCLIENT CARD
Levelsensors
High speed contactorturn-off contact(optional)
Relevelling zone
24 V
0 V
Y11
Y12
Y21
Y22Door safetyline shunt
Turn-off informationfrom the enable relay
90
22,5
90
113
68,6
118 +0,5–0
Examples of use
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/6
11
"Emergency stop" and "mobile guard monitoring"functions
"CE" conforming product / BG approved Control device with one or two channels Safety via redundancy and self-checking 3 "N/O" safety contacts with linked contacts - 6 A / 250 aa 1 "N/C" signalling contact Can be used to obtain level 3 according to NF.EN 954-1
"KNA3-XS" safety relay (22.5 mm)
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeMaximum response time onemergency stop Output specificationTypeNo. of safety circuitsNo. of data circuitsBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
< 25 ms< 50 ms
Volt-free outputs 3 “N/O" AgSnO2 contacts 1 “N/C" AgSnO2 contacts1500 VA resistive6.82 A440 VAC105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.6 VA / DC 2 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.42 kV when coupled10 V/m Level 3 acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)8 kV in the air acc. to IEC 1000.4.2Common mode 1 kV according to IEC1000.4.510 V rms Level 3 according to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor310 g
Technical characteristics
EMC immunity according to EN 50082-2
TypePart number (and voltage)
24 V a/c40/260 V a
ConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41NF-EN 60204-1NF-EN 292-1 and 2NF-EN 954-1NF-EN 418NF-EN 1088UL 508C22-2 No. 14-M91GS-ET-20
*Available 2nd half 1999
Connections
Key
A1-A2 : Power supply Control device(s)
Y1-Y2 : Start / validation13-14/23-24/33-34 : "N/O" safety contacts41-42 : "N/C" signalling contacts
KNA3-XS
85 100 036
* 85 100 037
Category 3
UL (C) UL BG
13 23 33
A1 Y1 Y2
13 23 33 41
14 24 34 42
A2 41 42
2414 34
KNA3-XS
OUT
PWR
1
Standard products
To order, specify :
Part number
Example : KNA3-XS safety relay : 85 100 036
1
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/7
11
Examples of use
Control devices :
Depending on the degree of safety required, KNA3-XS can receive thefollowing components as inputs :
- emergency stop pushbuttons with one or two contacts (A1-A2)
- position sensors (limit switches) with one or two contacts (A1-A2)
- pushbutton for start or validation (Y1-Y2)
A positive break operation device must be used if a single channel isused. (diagram 1)
To increase the degree of safety, one "N/C" auxiliary contact per powercontactor is wired in series with the start (or validation) pushbutton, toensure self-checking in this part of the installation. (diagram 2)
Dimensions Mounting - Removing
24 V
0V
C1 C2
13 23 33
14 24 34
A1 Y1 Y22313 33
14 24 3441A2 42
24 V
0V
C1
C1
C2
C2
13 23 33
14 24 34
A1 Y1 Y22313 33
14 24 3441A2 42
KNA3-XS wiring Control device with one
channel without return loopControl device with two
channels with return loop
Emergency stop Emergency stop
Two coils percontact
One coil percontact
Validation Validation
Control devices :
The KNA3-XS has three "N/O" safety contacts (13-14/23-24/33-34) and one"N/C" signalling contact (41-42). One or more control devices may be wired(diagram 1 and 2) up to the breaking capacity of the safety contacts : 1500VA. However, to limit internal heating in the KNA3-XS, it is advisable not toexceed 10 A thermal for all three contacts. The signalling contact cannot beused as a safety contact. The signalling contact can be wired on a PLC inputor integrated into a fault signalling system.
Extending the number of contacts :
The number of contacts of the KNA3-XS can be extended and the breakingcapacity thus increased. To do this, use the KZE3-XS (see page 11/20).
Diagram 1 Diagram 2
90
22,5
90
113
68,6
118 +0,5–0
KNA3-XS wired as category 2 KNA3-XS wired as category 3
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/8
11
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeMaximum response time onemergency stopOutput specificationTypeNo. of safety circuitsNo. of data circuitsBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
< 25 ms< 50 ms
Volt-free outputs 3 "N/O" AgSnO2 contacts 1 "N/C" AgSnO2 contacts 1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.6 VA / DC 2 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.44 kV directly for the 230 Va version2 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 4 kV for 230 Va
2 kV residual current modeCommon mode 2 kV for 24 Vc
and 24 Va
30 V rms Level X acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor310 g 24 AC DC410 g 115/230 AC
"Emergency stop" and "mobile guard monitoring"functions
"CE" conforming product / BG approved Control device with one or two channels Safety via redundancy and self-checking Integrity check on control devices 3 "N/O" safety contacts with linked contacts - 6 A / 250 aa 1 "N/C" signalling contact Separate return loop Can be used to obtain level 4 according to NF.EN 954-1
"KNA3-RS" safety relay (45 mm)
TypePart number (and voltage)
24 V a/c115 Va
230 Va
ConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41IEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
Key
A1-A2 : Power supplyY11-Y12 and Y21-Y22 : Redundant inputs with differentiated voltage for
control devicesY1-Y2 : Start / validationS1-S2 : Short-circuit protection on start / validation inputX1-X2 : Return loop13-14/23-24/33-34 : "N/O" safety contacts41-42 : "N/C" signalling contacts
KNA3-RS
85 100 43685 100 43485 100 435
Category 4
UL (C) UL BG
Y11 Y12 13 23 33
A1 X1 Y2
13 23 33 41
14 24 34 42
S1 S2 41
A2 PE Y21 Y22 42
X2 Y1 14 24 34
KNA3-RS
OUT
PWR
1
Standard products
To order, specify :
Part number
Example : KNA3-RS safety relay : 85 100 434
1
Technical characteristics
EMC immunity according to EN 50082-2
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/9
11
Examples of use
Control devices :
Depending on the degree of safety required, KNA3-RS canreceive the following components as inputs :- emergency stop pushbuttons with two contacts (Y11-Y12 andY21-Y22)
- position sensors (limit switches) with one or two contacts (Y11-Y12 and Y21-Y22)
- pushbutton for start or validation (Y1-Y2)
A positive break operation device must be used if a single contactis used.To increase the degree of safety, one "N/C" auxiliary contact perpower contactor is wired on terminals X1-X2 to ensure self-checking in this part of the installation.
Dimensions Mounting - Removing see page 11/7
Y11A1
+ 24 Vcc
0VC1 C2 C3
c3
c2
c1
13 23 33 41
14 24 34 42
X1 Y2 S1 S2 4123Y12 13 33
A2KNA3-RS
X2 Y1 14 24 34Y22PE Y21 42
Y11A1
+ 24 Vcc
0VC1 C2 C3
c3
c2
c1
13 23 33 41
14 24 34 42
X1 Y2 S1 S2 4123Y12 13 33
A2KNA3-RS
X2 Y1 14 24 34Y22Y21 42
S1 and S2 bridged forstart / validation inputprotection Compulsory :
S1 and S2 bridgedfor start / validationinput protectionEmergency stop
41-42 to PLC or faultcircuit
Start
Control devices :
The KNA3-RS has three "N/O" safety contacts (13-14/23-24/33-34) and one"N/C" signalling contact (41-42). One or more control devices may be wiredup to the breaking capacity of the safety contacts : 1500 VA. However, to limitinternal heating in the KNA3-RS, it is advisable not to exceed 10 A thermalfor all three contacts. The signalling contact cannot be used as a safetycontact.The signalling contact can be wired on a PLC input or integrated into a faultsignalling system.
Extending the number of contacts :
The number of contacts of the KNA3-RS can be extended and the breakingcapacity thus increased. To do this, use the KZE3-XS (see page 11/20).
"Light On" reflex cells
41-42 to PLC or fault circuit
90
45
90
113
68,6
118 +0,5–0
Start
KNA3-RS fitted with two cells LEVEL 2 SAFETY
KNA3-RS fitted with emergency stop with two channels + wired return loop.LEVEL 4 SAFETY
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/10
11
"KZP3-RS" safety relay (45 mm)
To order, specify :
"Emergency stop" and "mobile guard monitoring"functions
"CE" conforming product / BG approved Four input circuits for control device with one or two
channels Safety via redundancy and self-checking Integrity check on control devices 3 "N/O" safety contacts with linked contacts - 6 A / 250 aa 1 "N/C" signalling contact Can be used to obtain level 4 according to NF.EN 954-1
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeMaximum response time onemergency stopOutput specificationTypeNo. of safety circuitsNo. of data circuitsBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
< 25 ms< 50 ms
Volt-free outputs 3 "N/O" AgSnO2 contacts 1 "N/C" AgSnO2 contacts 1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 3 VA / DC 3 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.44 kV directly for the 230 Va version2 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 4 kV for 230 Va
Common mode 2 kV for 24 Vc
and 24 Va
30 V rms Level X acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor410 g
Key
A1-A2 : Power supplyY11-Y12 and Y21-Y22 : Redundant inputs with differentiated voltage for
control devicesY31-Y32 and Y41-Y42 : Redundant inputs with differentiated voltage for
control devicesY1-Y2 : Start / validationS1-S2 and S3-S4 : Short-circuit protection on start / validation input13-14/23-24/33-34 : "N/O" safety contacts41-42 : "N/C" signalling contacts
13 23 33 S3 Y32 Y42
A1 S1 S2
13 23 33 41
14 24 34 42
S4 Y31 Y41
A2 Y11 Y1 Y2 41 42
Y22Y12 Y21 14 24 34
KZP3-RS
OUT
PWR
1Technical characteristics
EMC immunity according to EN 50082-2
TypePart number (and voltage)
24 V a/cConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41IEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
KZP3-RS
85 100 536
Category 4
UL (C) UL BG
Standard products Part number
Example : KZP3-RS safety relay : 85 100 536
1
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/11
11
Examples of use
Control devices :
The KZP3-RS is used to obtain and maintain a category 4 level of safetyfor an installation with two control devices (see wiring example).Depending on the degree of safety required, KZP3-RS can receive thefollowing components as inputs :- emergency stop pushbuttons with two contacts (Y11-Y12 / Y21-Y22and Y31-Y32 / Y41-Y42)- position sensors with one or two contacts (Y11-Y12 / Y21-Y22 andY31-Y32 / Y41-Y42)- pushbutton for start or validation (Y1-Y2)A positive break operation device must be used if a single contact isused.To increase the degree of safety, one "N/C" auxiliary contact per powercontactor is cabled in series with the start (or validation) pushbutton, toensure self-checking in this part of the installation.
Dimensions Mounting - Removing see page 11/7
13A1
+ 24 V
0VC1 C2 C3
c3
c2
c1
13 23 33 41
14 24 34 42
S1 S2 S4 Y31 Y41Y3223 S3 Y4233
A2
AU1
Y22Y12 Y21 14 24 3441Y11 Y1 Y2 42
AU2
13A1
24 V
0VC1 C2 C3
c3
c2
c1
13 23 33 41
14 24 34 42
S1 S2 S4 Y31 Y41Y3223 S3 Y4233
A2Y22Y12 Y21 14 24 34
41Y11 Y1 Y2 42
S1-S2 and S3-S4 bridged for start /validation input protection
Start
Control devices :
The KZP3-RS has three "N/O" safety contacts (13-14/23-24/33-34) and one"N/C" signalling contact (41-42). One or more control devices may be wiredup to the breaking capacity of the safety contacts : 1500 VA. However, to limitinternal heating in the KZP3-RS, it is advisable not to exceed 10 A thermalfor all three contacts. The signalling contact cannot be used as a safetycontact. The signalling contact can be wired on a PLC input or integrated intoa fault signalling system.
Extending the number of contacts :
The number of contacts of the KZP3-XS can be extended and the breakingcapacity thus increased. To do this, use the KZE3-XS (see page 11/20).
90
45
90
113
68,6
118 +0,5–0
Start
PLCoutputs
PLC input
S1-S2 and S3-S4 bridged for short-circuitprotection on the validation line
Include an "N/C" contactfrom each power contactorin the start/validation line(return loop)
Cover
N/O N/C
LEVEL 4 LEVEL 4
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/12
11
"Emergency stop" and "mobile guard monitoring"functions
Safety timer function from 0.5 s to 30 s "CE" conforming product / BG approved Safety via redundancy and self-checking Integrity check on control devices 1 "N/O" instantaneous safety contact with linked contacts - 6 A / 250 Vaa
1 "N/O" timed safety contact with linked contacts - 6 A / 250 Vaa
1 "N/C" timed safety contact with linked contacts- 6 A / 250 Vaa
1 "N/C" timed signalling contact Can be used to obtain level 4 according to NF.EN 954-1
"KZR3-RS" safety relay (45 mm)
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeMaximum response time onemergency stopOutput specificationTypeNo. of instantaneous safetycircuitsNo. of timed safety circuits
No. of data circuitsBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-15% / +15% of Un for c1 power supply voltage LED
< 25 ms< 50 ms
Volt-free outputs 1 "N/O" AgSnO2 contact
1 "N/O" + 1 "N/C" AgSnO2 contact
1 "N/C" AgSnO2 contact1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.6 VA / DC 2 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.42 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 4 kV for 230 Va
Common mode 2 kV for 24 Vc
and 24 Va
30 V rms Level X acc. to IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor410 g
Technical characteristics
EMC immunity according to EN 50082-2
Y11 Y12 13 23 31
A1 Y1
13 23 41 31
14 24 32
K1 K3
K2 K4
42
Y2 41
A2 42
Y22Y21 14 24 32
KZR3-RS
OUT
PWR
1TypePart number (and voltage)
24 V a/cConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41IEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
KZR3-RS
85 100 736
Category 4
UL (C) UL BG
Standard products
To order, specify :
Part number
Example : KZR3-RS safety relay : 85 100 736
1
Key
A1-A2 : Power supply Y11-Y12 and Y21-Y22: Redundant inputs with differentiated voltage for
control devices
Y1-Y2 : Start / validation 13-14 : "N/O" instantaneous safety contact23-24 : "N/O" timed safety contact31-32 : "N/C" timed safety contact41-42 : "N/C" timed data contact
A1-A2
Y1-Y2
Y11-Y12Y21-Y2213-14
27-2835-36
45-46
Power-up
Timed
* instantaneous outputs. Category 3 according to EN 954 1 on timed outputs
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/13
11
Examples of use
Control devices :
Depending on the degree of safety required, KZR3-RS can receive thefollowing components as inputs :
- emergency stop pushbuttons with two contacts (Y11-Y12 and Y21-Y22)
- position sensors (limit switches) with one or two contacts (Y11-Y12 and Y21-Y22)
- auxiliary contact for electromagnetic lock (Y11-Y12 and Y21-Y22)
- pushbutton for start or validation (Y1-Y2)
A positive break operation device must be used if a single contact isused.
Dimensions Mounting - Removing see page 11/7
Y11A1
24 V C1
C2
0V
c2
c113
KZR3-RS
23 3141
14 24 32K4
K3
K2
Y1
Y2
K1
42
Y1 Y2 4123Y12 3113
A2Y22Y21
Y12
Y22
14 24 32M42
Y21
C1 C2Y12
OP
EN
ING
Start
Emergencystop
Opening
Control devices :
The KZR3-RS has one "N/O" instantaneous safety category 4 contact(13-14), one "N/O" timed safety category 3 contact (23-24) and one "N/C"(31-32) timed safety category 3 contact, and one "N/C" (41-42) signallingcontact. One or more control devices may be wired (diagram 1 and 2) upto the breaking capacity of the safety contacts : 1500 VA.
Extending the number of contacts :
The number of contacts of the KZR3-XS can be extended and thebreaking capacity thus increased. To do this, use the KZE3-XS (see page11/20).
Y11A1
C1
C3
13
KZR3-RS
23 3141
14 24 32K4
K3
K2
Y2
K1
42
Y1 Y2 4123Y12 3113
A2Y22Y21
Y12Y22
14 24 32M142Y1
Y11Y21
C1 C2 C4C3
C3
C2 C4
M2
c3
c2
c1
c4
90
45
90
113
68,6
118 +0,5–0
KZR3-RS used for deferred access KZR3-RS used for breaking M1 and M2 in sequence
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/16
11
"KZH2-XS" safety relay (22.5 mm)
Type III C "2-hand control" functions according to EN 574/97 "CE" conforming product with type-examination BG approved product INRS certification : Q3.99 Control device with two channels Safety via redundancy and self-checking Integrity check on control devices 2 "N/O" safety contacts with linked contacts - 6 A / 250 Vaa
Can be used to obtain level 4 according to NF.EN 954-1
13 23 Y11
A1 Y12 Y13
13 23
14 24
A2 Y22 Y23
2414 Y21
KZH2-XS
OUT
PWR
Power supplyPower supply voltage
Operating range
On/off indication
AccuracySynchronisation differenceResponse time on release ofcontrol device
Output specificationTypeNo. of safety circuits Breaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed powerOn/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-10% / +15% of Un for c1 power supply voltage LED
< 500 ms< 20 ms
Volt-free outputs 2 "N/O" AgSnO2 contacts1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
AC 1.5 VA / DC 1.5 W1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.42 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 2 kV for 24 Vc
and 24 Va
10 V rms on inputs / Level 3 accordingto IEC 1000.4.630 V rms on supp. / Level X accordingto IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor230 g
Technical characteristics
EMC immunity according to EN 50082-2
Standard products
To order, specify :
Part number
Example : KZH2-XS safety relay : 85 100 626
1
TypePart number (and voltage)
24 V a/cConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41European "EMC" Directive 89 336/EECIEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 574 / 97EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
KZH2-XS
85 100 626
Type III C Category 4
UL (C) UL BG
Key
A1-A2 : Power supplyY11-Y12-Y13 and : Redundant inputs with differentiated voltageY21-Y22-Y23 for control devices13-14 / 23-24 : "N/O" safety contacts
1
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/17
11
Examples of use
Control devices :
The KZH2-XS can receive the following components as inputs :
- two pushbuttons with two positions "N/O" + "N/C" (Y11-Y12-Y13 andY21-Y22-Y23)
- one or two emergency stop pushbuttons with one or two channels (A1-A2).
Control devices :
The KZH2-XS has two "N/O" safety contacts (13-14/23-24). One or morecontrol devices may be wired up to the breaking capacity of the safetycontacts : 1500 VA. However, to limit internal heating in the KZH2-XS, it isadvisable not to exceed 8 A thermal for both contacts.
Dimensions Mounting - Removing see page 11/7
24 V
0V
C1 C2
13 23
14 24
A1 Y12 Y132313 Y11
14 24 Y21
KZH2-XS
Y22A2 Y23
Emergency stop
2-handcontrolconsole
Extending the number of contacts :
The number of contacts of the KZH2-XS can be extended and thebreaking capacity thus increased. To do this, use the KZE3-XS (see page 11/20
90
22,5
90
113
68,6
118 +0,5–0
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/18
11
Type III C "2-hand control" functions according to EN 574/97 "CE" conforming product with type-examination BG approved product INRS certification : Q3.99 Control device with two channels Safety via redundancy and self-checking Integrity check on control devices 3 "N/O" safety contacts with linked contacts - 6 A / 250 Vaa
1 "N/C" signalling contact Can be used to obtain level 4 according to NF.EN 954-1
"KZH3-RS" safety relay (45 mm)
Power supplyPower supply voltage
Operating range
On/off indication
AccuracyReset timeMaximum response time onemergency stop at UnOutput specificationTypeNo. of safety circuitsNo. of data circuitsBreaking capacityMax. current breaking capacityMax. voltage breaking capacityElectrical life
Mechanical lifeOperation and useMax. absorbed power
On/off indicationOperating temperatureStorage temperatureInternal voltageDielectric strengthResistance to tracking
Rapid transients
Radiated electromagnetic field
Electrostatic dischargesShock waves
Radio frequencies in commonmode
Drop-out / short breaks /microbreaks
* the device operates normally** the device has not faileddangerouslyCasingMaterial
Degree of protection
Terminal capacity
Weight
a 24 V 50/60 Hzc 24 V max. ripple 10%-15% / +10% of Un for a-10% / +15% of Un for c1 power supply voltage LED
< 500 ms< 20 ms
Volt-free outputs 3 "N/O" AgSnO2 contacts 1 "N/C" AgSnO2 contacts 1500 VA resistive6.82 A440 Va
105 operations at 1500 VA resistive5.105 operations at 500 VA resistive107 operations
24 AC 1.5 VA / 24 DC 1.5 W / 115-230 AC 3.2 VA1 internal relay status LED0°C to +50°C acc. to IEC 68-2-14-20°C to +70°C acc. to IEC 68-1/224 Vc
2.95 kV according to IEC 664-1Material group III
2 kV directly acc. to IEC 1000.4.44 kV directly for the 230 Va version2 kV when coupled30 V/m Level X acc. to IEC 1000.4.380 MHz to 1 GHz / 900 MHz (ENV 50140/204)15 kV in the air acc. to IEC 1000.4.2Level 3 according to IEC 1000.4.5Common mode 4 kV for 230 Va
2 kV residual current modeCommon mode 2 kV for 24 Vc
and 24 Va
10 V rms on inputs / Level 3 accordingto IEC 1000.4.630 V rms on supp. / Level X accordingto IEC 1000.4.6150 kHz to 80 MHz (ENV 50141)according to IEC 1000.4.11Un-30% for 10 ms every 1 sUn-60% for 100 ms every 1 saccording to IEC 61496-1/97Un-100% for 10 ms every 100 ms*
Un-50% for 20 ms every 200 ms*
Un-50% for 500 ms every 5 s**
PolycarbonateSelf-extinguishing - UL94 class VOCasing : IP40Terminal : IP202 X 1.5 mm2 multicore with ferrule2 X 2.5 mm2 solid conductor310 g 24 AC/DC410 g 115-230 AC
TypePart number (and voltage)
24 V a/c115 Va
230 Va
ConformityEuropean "Machinery" Directive 89/392/EECFrench Decree 92/765-766-768European "Usage" Directive 89/655/EECFrench Decree 93-40 / 93-41European "EMC" Directive 89 336/EECIEC 61496-1IEC 664-1EN 50081-2EN 50082-2EN 60204-1EN 292-1 and 2EN 574 / 97EN 954-1EN 418EN 1088UL 508C22-2 No. 14-M91GS-ET-20
Connections
Key
A1-A2 : Power supplyY11-Y12-Y13 and : Redundant inputs with differentiated voltageY21-Y22-Y23 for control devices13-14/23-24/33-34 : "N/O" safety contacts41-42 : "N/C" signalling contacts
KZH3-RS
85 100 63685 100 63485 100 635
Type III C Category 4
UL (C) UL BG
Y12 Y11 Y13 13 23 33
A1 N1 N1
13 23 33 41
14 24 34 42
41
A2 PE 42
Y21Y22 Y23 14 24 34
KZH3-RS
OUT
PWR
1
Standard products
To order, specify :
Part number
Example : KZH3-RS safety relay : 85 100 634
1
Technical characteristics
EMC immunity according to EN 50082-2
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/19
11
Examples of use
Control devices :
The KZH3-RS can receive the following components as inputs :
- two pushbuttons with two positions "N/O" + "N/C" (Y11-Y12-Y13 andY21-Y22-Y23)
- one or two emergency stop pushbuttons with one or two channels (A1-A2).
Control devices :
The KZH3-RS has three "N/O" safety contacts (13-14/23-24/33-34) and one "N/C" signalling contact (41-42). One or more controldevices may be wired up to the breaking capacity of the safety contacts :1500 VA. However, to limit internal heating in the KZH3-RS, it is advisablenot to exceed 10 A thermal for all three contacts.
Dimensions Mounting - Removing see page 11/7
+ 24 V
S1
S2
0V
Y12A1
KZH3-RS
N1 N1 4123Y11 Y13 3313
A2Y21Y22 Y23 14 24 34PE 42
13 23 33 41
14 24 34 42
C1 C2 C3
Emergencystop
Sig
nalli
ng
Extending the number of contacts :
The number of contacts of the KZH3-RS can be extended and thebreaking capacity thus increased. To do this, use the KZE3-XS.
+ 24 V
S1
S2
0V
Y12A1
KZH3-RS
KZE3-XS
N1 N1 4123Y11 Y13 3313
A2Y21Y22 Y23 14 24 34PE 42
13 23 33 41
14 24 34 42
A1 X1 X223 3313
A2 4114 24 34
42
13 23 33
14 24 34
C3C1 C2 C4 C5
90
45
90
113
68,6
118 +0,5–0
Emergencystop
KZH3-RS KZH3-RS with KZE3-X3 extension module
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/24
11
Safety component
CertificationMechanical lifeElectrical life
Working current
(A) 1410 62
Insulation voltage
Voltage for withstanding shocksElectrical A.C.performance Working voltage
(50 -60 Hz)
Ue (V)230400440500690D.C.Working voltage
Ue (V) 24 V 48 V60 V110 V220 V
Protection against short-circuits
Temperature limits UseStorage
Terminal capacity
Connection
Protection indices PushbuttonBox
Technical characteristics of contacts TypePart numbers1 "N/C" contact1 "N/O" contact Contact mounting bracketMetal label, diameter 80, yellowPush-pull head with 2 stable positionsPush-turn head with 2 stable positionsLocking head with key (supplied)Mushroom head D = 70 black 1 "N/C + 1 "N/O"Mushroom head D = 70 blackSymbol
ConformityEuropean "Machinery" Directive 89/392/EECFrench Decrees 92/765-766-767-768European "Usage" Directive 89/655/EECFrench Decrees 93-40 and 93-41European standard NF EN 60204-1(Machine safety - Electrical equipment)
European standards NF EN 292-1 and 2(Machine safety - Basic concepts
European standard NF EN 418(Machine safety - Emergency stop devices)
Emergency stop pushbuttons for safety applications
Ø 22 control unit with mechanical latch
"CE" conforming product
Positive opening contacts
Pushbutton with positive mechanical action acc. to EN 418
Dimensions
Mushroom head
79 697 003 79 697 00479 697 00579 697 00679 697 00879 697 00979 697 01079 697 10179 697 011
Cut-outs for consoles and cabinets
45
Ø22,3
40
+0,4-0
4030
34
5025
Ø 40
Standard products
Standard products,non stocked
To order, specify :
Part number
Example : Emergency stop pushbuttons for safety applications 79 697 003
1
1Positive openingcontactsUL, CSA3 x 106 operationsOperating categoryAC21 230 V/50 - 60Hzconforms to IEC 947-3Number of operations
(x 106)0.20.513
Degree of pollution3-690 V conforms toUTE, VDE, IEC forflush-mountingU impulse : 6 kV
Working current
(IEC 947-3) (IEC 947-5-1)AC21 AC15Ie (A) Ie (A)14 612 4.511 3.510 2.56 1
Working current
(IEC 947-5-1)DC13Ie (A) 1.5 A1 A0.7 A0.3 A0.2 AHPC fuse 10 A gl - gGconforms to IEC 269- 30 to + 60 °C- 50 to + 80 °C2 x 2.5 mm2 with cableendsVia captive screw terminals IP 65IP 657 double insulation
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/25
11
To order, specify :
30 40
34
5024
,5
Ø 70210
400 25
45
80
130
100
85 100 293 85 100 292
79 697 001
79 697 101
Part numbersKSP2 two-hand control consoleKSP console fixing foot
Mushroom head Emergency stop
Spring-return pushbuttons
Dimensions
Can be ordered separately
Two-hand control console
Used in conjunction with a "KZH3" safety startmodule for two-hand control applications : folding,clipping, punching, rail-cutting, bending, drilling,presses, etc.
Supplied with an emergency stop button and 2 spring-return mushroom head pushbuttons.
Conforms to EN 574 concerning safety applications
Push-pull 2 "N/C" + 1 "N/O"(red pushbutton + contacts + Ø 80 metal yellow label)Mushroom head Ø 70 black 1 "N/C" + 1 "N/O"
Standard products
Standard products,non stocked
Part number
Example : 2-hand control console - 85 100 293
1
1
85 100 291 85 100 292 79 697 101
~ 8
00
500 to 1000
250 to 500
Range of limit switches to standard EN 50041
Metal case and actuator head Snap action contact NC+NO with positive break
operation Conforms to IEC 947.5.1. A300 AC15 6A 250 VAC UL / CSA approved IP 66 Temperature range : -25 +80°C
Limit switches see page 7/8
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/42
11
Type of contact1 “NC+NO”2 “NC+NO”1 “NC+NO”PlasticMetal
To order, specify :
Standard products
Standard products,non stocked
1
Part numberExample : Metal foot switch 83 895 1011
Foot switch for machine tools, wood workingmachines, rubber and plastics machines, mouldingpresses
Plastic foot switch :without interlock at rest position
Metal foot switch :with interlock at rest position and protective cover
Plastic or metal foot switches, with or without interlock at rest position
EnvironmentConforming to standards
CertificationsProtective treatmentTemperature Use
StoredVibration resistanceShock resistance
Degree of protection
Mechanical life
Cable entry
Plastic MetalIEC 947-5-1, IEC 947-5-1,EN 60 947-5-1, EN 60 947-5-1,VDE 0660-200, VDE 0660-200,UL 508, UL 508,CSA C22-2 no. 14 CSA C22-2 no. 14
With protective cover :NFE 09-031
FI FI, CSA"TC"-25°C, +70°C-40°C, +70°C15 gn (10…150 Hz)25 gn 20 gn acc. to IEC 68-2-27 acc. to IEC 68-2-27
(150 gn acc. to NF E 09-031)
IP 43 IP 66acc. to IEC 529 acc. to IEC 5292 million 5 millionoperations operations2 untapped 2 threaded holes for cable holes for cablegland gland
General characteristics Part numbers
Assigned working characteristics
Assigned insulation voltage
Assigned impulse voltage
Electric shock protection
Resistance between terminalsShort-circuit protection
AC 15 A300 Ue = 240 V, Ie = 3 ADC 13 Q300 Ue = 250 V, Ie = 0.27 AUi = 500 V, degree of pollution 3according to IEC 947-5-1Ui = 300 V according to UL 508, CSA C22-2 no. 14Uimp = 6 KV according to IEC 947-5-1Class 2 Class 1,acc. to IEC 536 acc. to IEC 536and NF C 20-030 and NF C 20-030≤ 25 mΩ according to IEC 954-5-4Cartridge fuse 10 A gG (gl)
Electrical characteristics
83 895 001
83 895 030
83 895 101
1
Part numberExample : Plastic foot switch 83 895 001
Operating principleOperating frequency (maximum)
Weight
1 step 2 steps 1 step600 / hr 600 / hr 600 / hr
0.275 kg 0.295 kg 2.570 kg
Additional characteristics
Plastic Metal
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/43
11
Other information
Presentation83 895 0 and 83 895 101 foot switches are an ideal solution forcontrolling starting and stopping of numerous industrial machines withmany different operating modes : pulsed, step-by-step, continuous.
The range comprises metal foot switches (for heavy loads where thereis an increased risk) for heavy duty requirements, and plastic footswitches (for lighter loads where there is a reduced risk).
Fitted with a protective cover, metal foot switch83 895 101 should be used whenever astart/stop command could pose a danger(increased risk).
83 895 0 foot switches without covers aresuitable for start commands which pose areduced risk and for machine stopcommands.
Safety contactsDevices with snap action positive break type contacts.
Metal foot switches can have one or two “NC + NO” contact blocks.These foot switches are in positive operation when released : positiveactuation is required to maintain the machine in rest mode or cause it tostop (machine stop).
TerminologyPositive break operationA device meets the requirements of this specification when all its normallyclosed contact elements can be safely set to their opening position.
All foot switches fitted with a snap action “NC+NO” contact element arepositive break type and meet all the requirements of standard IEC 947-5-1,section 3.
Snap action contactThe linear speed of the moving contacts is independent of the speed of thecontrol device. This feature enables high levels of electrical performance,even with low control device linear speeds.
2-step pedalsPedals with two steps are ideal for machines with two operating speeds.
Examples :- first speed : slow (used for tool adjustment or maintenance),- second speed : fast (used for normal machine operation).
The first step, connected to an “NC + NO” contact, is achieved by brieflyapplying gentle pressure to the foot switch (6 mm and 2 daN depression).
The second step, connected to a second “NC + NO” contact, is achievedby applying maximum pressure to the foot switch (12 mm and 9 daN fordepression up to the end stop).
172,5
152
146,510,5
137
16,5
14,5
29
186
3XØ9
31=
89,5
=
135
==
160
54
154
6
11
23
94
==
161
Ø6,4
28
2 threaded holesfor cable entry
maximum capacity14 mm
1 untapped hole for cable entrymaximum capacity 12 mm
1 untapped hole for cable entrymaximum capacity 8 mm
6 mm
12 mm
1st step
2nd step
Dimensions83 895 101 with protective cover 83 895 0
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/44
11
To order, specify :
Accessory
100 mm tube, supplied withclamping system on base
Pedestal on horizontal support, fortube mounting
Pedestal on vertical support Direct mounting on base orpedestal
Base with axial or lateral cableentry and cover
83 895 207
83 895 208
83 895 209
83 895 210
Illuminated lens unitsGreenRedOrangeBlueClearYellow
Standard products,non stocked
1 2 Bulb3
Illuminated indicator banks
EnvironmentCertifications
Protective treatment
Ambient air Usetemperature StoredElectric shock protection
Degree of protection
Materials Lens unitsBase and coverTubePedestal
In normal operation : CSA,UL : a 240 V maximumIn normal operation : "TC" treatment
-10°C, +55°C-20°C, +70°CDirect mounting : class II.Tube mounting : class I according toIEC 536 and NF C 20-030IP 42 according to IEC 529 andNF C 20-010, vertical, base unitunderneathPolycarbonateGlass polyamideAnodised aluminiumPolycarbonate or aluminium
General characteristics Part numbers
Mounting accessories
Assigned insulation voltage
Assigned impulse voltage
Type of bulb
Terminal labelling
Connection
Ui = 250 V according to IEC 947-1
Uimp = 4 kV according to IEC 947-1
Fixed signalling lens unit : BA15dbase fitting bulbs, power 10 W
1 terminal labelled “NC” (C) commonto the 5 units, 1 or 5 terminalslabelled from 1 to 5 according to thenumber of unitsOn protected and open terminalswith captive screw clamps : max.clamping capacity : 2 x 2.5 mm2
Electrical characteristics
83 895 20183 895 20283 895 20383 895 20483 895 20583 895 206
1
2
BA 15 d base fitting, 10 W 24 VBA 15 d base fitting, 10 W 120 VBA 15 d base fitting, 10 W 230 V
79 214 58679 214 58779 214 588
Incandescent bulbs 3
Modular illuminated indicator banks
1 to 5 lens units
Connection diagram
45
53
1
1
2
N
Part numberExample : Blue lens unit 83 895 204 - Pedestal 83 895 209 - Bulb 79 214 588
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com
11/45
11Other information
General informationType 83 895 2 indicator banks are optical signalling devices used inparticular for 360° remote signalling of the various states and sequencesof a machine or installation.Examples : operation, machine stop, missing materials, paging personnel,fault signalling, etc
The indicator bank is modularIt forms an assembly which can be constructed to form several differentversions with between one and five lens units, and is not assembled ondelivery (to be assembled by the customer).It comprises :1 - A base with a removable connection terminal block and an axial orlateral cable entry.2 - One to five green, red, orange, blue, clear or yellow lens units.3 - A cover on the top section.The lens units fit together easily by stacking one on top of the another andcan be locked and unlocked using a built-in peripheral nut.Electrical connection of the various parts is automatic.Accessories :4 - 100 mm tube.5 - Pedestal screwed onto the tube for fixing it to the horizontal support.6 - Pedestal for fixing to the vertical support.
InstallationFixing : direct fixing of the base to the support using 2 screws or using apedestal screwed onto the tube.Wiring : this is carried out on the removable connection terminal blockwhich is built into the base (to make wiring easier). The terminals areprotected to make the screw clamps captive and to avoid any contact withlive parts.
DimensionsTube 83 895 207 and pedestal 83 895 208 Pedestal 83 895 209, direct mounting on base
Drilling of horizontal support forfixing on pedestal 83 895 208
Mounting using pedestal 83 895 208screwed onto tube 83 895 207
Drilling of verticalsupport for fixing onpedestal 83 895 207
3
2
1
4
5
6
2
1
100
Ø70
==
68
51,5
25,5
114
1
2 10
0
114 25
,5 50
41,5
3xØ5 ou M5
54
54
Ø27 4xØ5,5 ou M5
1 Tube 83 895 207, Ø 25 mm2 Pedestal on horizontal support 83 895 208
1 Tube Ø 25 mm2 Pedestal on vertical support 83 895 209
C
ourte
sy o
f Ste
ven
Eng
inee
ring,
Inc.
2
30 R
yan
Way
, Sou
th S
an F
ranc
isco
, CA
, 940
80-6
370
Mai
n O
ffice
: (65
0) 5
88-9
200
Out
side
Loc
al A
rea:
(800
) 258
-920
0
ww
w.s
teve
neng
inee
ring.
com