extensive range. proven design. - euro-glas

13
DURAN ® VOLUMETRIC FLASKS MEASURING AND MIXING CYLINDERS Extensive range. Proven design.

Upload: others

Post on 17-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Extensive range. Proven design. - Euro-Glas

DURAN® VOLUMETRIC FLASKSMEASURING AND MIXING CYLINDERS

Extensive range. Proven design.

Page 2: Extensive range. Proven design. - Euro-Glas

2 3Table of conTenTs

DURan® volUmeTRic glasswaRe: achieving pRecision ThRoUgh qUaliTy 03

DURan® laboRaToRy glasswaRe: enD To enD pRoDUcTion fRom a single soURce 04

foR The highesT DemanDs: qUaliTy RighT Down The line 05

gUaRanTeeD: all opTions coveReD 07

pRecise DiffeRenTiaTion: The Two accURacy classes 08

qUaliTy: expResseD in coloUR 09

ceRTificaTes: TesT ResUlTs cleaRly DemonsTRaTeD 10

DURan® volUmeTRic flasks: assisTing in measURemenT analysis 11

DefiniTive laseR maRking fRom DURan®: RUling oUT mix-Ups 18

DURan® measURing cylinDeRs: Two applicaTions in one 19

DURan® mixing cylinDeRs: cReaTing compoUnDs 21

DURan® polyeThylene sToppeR: exTRemely pRacTical solUTion 23

DURan® volUmeTRic glasswaRe: achieving pRecision ThRoUgh qUaliTy

measuring volumes is a routine task for a laboratory. it is therefore all the

more important to ensure the long term quality of the instruments required

for this, from volumetric flasks through to stoppers. Day in day out, for

every analysis.

like all DURan® laboratory glassware, DURan® volumetric glassware

exhibits excellent thermal durability, it is practically inert and is characterised

by its extremely high thermal shock resistance. it is also highly cost effective

thanks to its distinctive anti-corrosion properties.

in short, DURan® volumetric glassware ensures that undesirable influences

are minimised as much as possible, therefore ensuring constantly high

precision with every measurement.

Typical curvature of the liquid surface (meniscus)

Page 3: Extensive range. Proven design. - Euro-Glas

4 5DURan® laboRaToRy glasswaRe: enD To enD pRoDUcTion fRom a single soURce

strict guidelines are followed in the selection of raw materials and batch

preparation for borosilicate glass 3.3. moreover, the excellent quality of

DURan® laboratory glassware is guaranteed by concentrating production

fully at the company's own locations. This is the case with every phase of

production – from glass melting through to calibration.

The result: the highest possible precision when it comes to measuring

volumes.

foR The highesT DemanDs: qUaliTy RighT Down The line

whether measuring liquid amounts, diluting solutions or mixing several components – DURan®

volumetric products, such as volumetric flasks, measuring and mixing cylinders to cover all applications.

Top quality process stability for all aspects of volume measurement can therefore be guaranteed in the

laboratory. high levels can be expected for all other laboratory activities that use DURan® laboratory

glassware.

Page 4: Extensive range. Proven design. - Euro-Glas

6 77

"i am always able To balance RoUTine anD pRecision … Thanks To PERFECT GLASSWARE"

The DURan® range of volumetric measurement products is characterised by an impressive array

of advantages in addition to the products being manufactured from the chemically highly resistant

borosilicate glass 3.3 that offers chemical, thermal and mechanical stability.

for example:

Unrestricted choice – The range of products on offer covers all accuracy classes including the

associated certifi cates and glass specifi cations

excellent print image − Emphasises the most important information, such as volume specifi cation,

accuracy class and standard ground joint details

clear labelling − Batch numbers are imprinted clearly on the glass, while individual numbers are

laser-etched onto the base of the volumetric fl ask

gUaRanTeeD: all opTions coveReD

in addition, the range also includes new

ergonomically shaped stoppers for simple and

secure opening and closing (see page 23).

Page 5: Extensive range. Proven design. - Euro-Glas

8 9pRecise DiffeRenTiaTion: The Two accURacy classes

Two accuracy classes "a" and "b" are essentially available for classifying the DURan® volumetric flasks,

measuring and mixing cylinders.

accuracy class "a":

indicates the accuracy limit in accordance with Din and iso and is therefore the highest accuracy class.

"a" apparatus bears the conformity symbol "h", which indicates that the requirements of the german

weights and measures regulations as well as the relevant standards are fulfilled.

Tolerance for a volumetric flask in accuracy class "A"

Tolerance for a volumetric flask in accuracy class "B"

accuracy class "b"

indicates an accuracy limit that is double that of class "a".

0391701-SZ1

D U R A N

SCHO

ISO 1042A±0.15mlIn 20°C

NS 14/23250 Volumetric flask, accuracy class A

0395301-SZ1

ISO 1042B±0.3mlIn 20°C

NS 14/23250D U R A N

SCHO UKVolumetric flask, accuracy class B

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250Volumetric flask, accuracy class A, conforms with Usp <31>

aaa-0001

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

DD.mm.yy

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

0395301-SZ1

ISO 1042B±0.3mlIn 20°C

NS 14/23250D U R A N

SCHO UK

0391701-SZ1

D U R A N

SCHO

ISO 1042A±0.15mlIn 20°C

NS 14/23250

0397301-SZ1

USP

D U R A N

SCHO

ISO 1042A±0.12mlIn 20°C

NS 14/23250

All glassware is heated in an oven following printing and the colour is fired on to the glass. This procedure

guarantees the high chemical and thermal resistance of the enamel print used, and therefore their

long life and economic efficiency. Important information, such as volume, accuracy class and the

schoTT DURan® logo, should therefore remain clearly visible as quality features in the long term.

qUaliTy: expResseD in coloUR

in order to ensure better differentiation, the accuracy classes are indicated by a high contrast colour

code:

accuracy class "a",

clear glass:

printed in blue.

accuracy class "a",

amber glass:

printed in white

accuracy class "b",

clear glass only:

printed in white

2

4

4

1

1

3

2

3

individual number (lasered onto base)

United states pharmacopeia – the product fulfils the requirements specified in USP<31>

production date (lasered onto base)

nominal volume in ml

accuracy limit – the nominal volume can deviate at most by this value as specified in the standards

calibrated to contain. The quantity of liquid contained corresponds to the volume indication printed on the item.

Reference temperature – the temperature at which volumetric glassware must contain its specified nominal volume (20°C).

accuracy class – indicates the accuracy limit (see page 8)

standard ground joint size

standardised designation

country of origin

batch number, e.g. 14.01

"H" conformity symbol – confirms that the requirements of the german federal weights and measures Regulations as well as the relevant standards are fulfilled.

Page 6: Extensive range. Proven design. - Euro-Glas

d

h

10 11

conformity symbol h – The conformity symbol confirms that the apparatus fulfils the requirements of

the german weights and measures regulations as well as the relevant standards. This conformity with

Din 12 600 is printed directly on the glass.

Batch certificate – Volumetric flasks as well as measuring and mixing cylinders that are assigned to

accuracy class "A" and have a batch number come with a batch certificate. This certificate documents

the mean value derived from measuring the specified batch as well as the standard deviation and the

date of issue. The batch certificates are also available online.

The batch number comprises four digits, for example:

The first two digits indicate the batch and the second two digits indicate the year of production.

Individual certificate – Volumetric flasks that bear an individual number in addition to the batch number

come with an individual certificate. The individual number is lasered permanently onto the base of the

volumetric flask and entered on the associated certificate. Each volumetric flask is measured and test-

ed individually. This certificate documents the volume measured for the respective volumetric flask, the

uncertainty measurement and the date of issue. A batch certificate is also available as an option online.

The individual number is a consecutive number and comprises three letters and a four digit number,

for example: aaa-0001

USP individual certificate – The volumetric flasks are assigned an individual number. This number is

lasered permanently onto the base of the volumetric flask and entered on the associated certificate.

The accuracy limits for volumetric flasks that conform to USP <31> are stricter than for volumetric

flasks that conform to ISO 1042 and therefore fulfil the requirements contained in the United States

Pharmacopeia (USP). Each volumetric flask is measured and tested individually. This certificate

documents the volume measured for the respective volumetric flask, the measuring inaccuracy and

the date of issue.

DURan® volUmeTRic flask, class a, confoRms wiTh Usp <31>

blue graduation, with one graduation mark and new ergonomic polyethylene stopper

Certificate of conformity "H"

With USP individual certificate

DURan® volUmeTRic flasks: assisTing in measURemenT analysis

DURan® volumetric flasks are used to precisely measure specified amounts

of liquid in conjunction with the preparation and storage of solutions.

An individual or batch certificate for the volumetric flask is enclosed with

the product. The batch certificates are also available online.

ceRTificaTes: TesT ResUlTs cleaRly DemonsTRaTeD

w1 – wide neck

precise reading made simple

The liquid at the edge of the vessel is

generally higher and therefore forms what

is known as the meniscus. The difficulty this

creates with reading can be avoided by

reading off at the lowest point of the liquid

surface. This means that the lowest point of

the meniscus should touch the top edge of

the measurement mark precisely.

Batch certificate Individual certificate

Cat. No.: Capacityml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 671 09 58 5w1 0.02 70 22 10/19 9 ± 1 2

24 671 10 54 10w1 0.02 90 27 10/19 9 ± 1 2

24 671 14 57 25 0.03 110 40 10/19 9 ± 1 2

24 671 17 57 50 0.05 140 50 12/21 11 ± 1 2

24 671 25 56 100 0.08 170 60 14/23 13 ± 1 2

24 671 32 52 200 0.1 210 75 14/23 15.5 ± 1.5 2

24 671 36 55 250 0.12 220 80 14/23 15.5 ± 1.5 2

24 671 44 54 500 0.2 260 100 19/26 19 ± 2 2

24 671 54 59 1000 0.3 300 125 24/29 23 ± 2 2

24 671 63 52 2000 0.5 370 160 29/32 27.5 ± 2.5 2

Page 7: Extensive range. Proven design. - Euro-Glas

12 13DURan® volUmeTRic flask, class a

blue graduation, with one graduation mark and new ergonomic polyethylene stopper

Certificate of conformity "H"

With individual certificate

w1 – wide neck

DURan® volUmeTRic flask, class a

blue graduation, with one graduation mark and new ergonomic polyethylene stopper

Certificate of conformity "H"

With batch certificate

w1 – wide neck

Cat. No.: Capacity ml

Accuracy limit ± ml

Overall height h mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 679 01 51 1 0.025 65 13 7/16 7 ±1 2

24 679 02 54 2 0.025 70 17 7/16 7 ±1 2

24 679 09 57 5w1 0.04 70 22 10/19 9 ±1 2

24 679 10 53 10w1 0.04 90 27 10/19 9 ±1 2

24 679 12 59 20 0.04 110 39 10/19 9 ±1 2

24 679 14 56 25 0.04 110 40 10/19 9 ±1 2

24 679 17 56 50 0.06 140 50 12/21 11 ±1 2

24 679 24 52 100 0.1 170 60 12/21 13 ±1 2

24 679 25 55 100 0.1 170 60 14/23 13 ±1 2

24 679 32 51 200 0.15 210 75 14/23 15.5 ± 1.5 2

24 679 36 54 250 0.15 220 80 14/23 15.5 ± 1.5 2

24 679 44 53 500 0.25 260 100 19/26 19 ± 2 2

24 679 54 58 1000 0.4 300 125 24/29 23 ± 2 2

24 679 55 52 1000w1 0.6 300 125 29/32 27.5 ± 2.5 2

24 679 63 51 2000 0.6 370 160 29/32 27.5 ± 2.5 2

24 679 73 56 5000 1.2 475 215 34/35 38 ± 3 1

Cat. No.: Capacity ml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 678 01 59 1 0.025 65 13 7/16 7 ± 1 2

24 678 02 53 2 0.025 70 17 7/16 7 ± 1 2

24 678 09 56 5w1 0.04 70 22 10/19 9 ± 1 2

24 678 10 52 10w1 0.04 90 27 10/19 9 ± 1 2

24 678 12 58 20 0.04 110 39 10/19 9 ± 1 2

24 678 14 55 25 0.04 110 40 10/19 9 ± 1 2

24 678 17 55 50 0.06 140 50 12/21 11 ± 1 2

24 678 24 51 100 0.1 170 60 12/21 13 ± 1 2

24 678 25 54 100 0.1 170 60 14/23 13 ± 1 2

24 678 32 59 200 0.15 210 75 14/23 15.5 ± 1.5 2

24 678 36 53 250 0.15 220 80 14/23 15.5 ± 1.5 2

24 678 44 52 500 0.25 260 100 19/26 19 ± 2 2

24 678 54 57 1000 0.4 300 125 24/29 23 ± 2 2

24 678 55 51 1000w1 0.6 300 125 29/32 27.5 ± 2.5 2

24 678 63 59 2000 0.6 370 160 29/32 27.5 ± 2.5 2

24 678 73 55 5000 1.2 475 215 34/35 38 ± 3 1

Page 8: Extensive range. Proven design. - Euro-Glas

14 15 DURan® volUmeTRic flask, ambeR, class a

white graduation, with one graduation mark and new ergonomic polyethylene stopper

Certificate of conformity "H"

With individual certificate

w1 – wide neck

DURan® volUmeTRic flask, class a

white graduation, with one graduation mark and polyethylene octagonal stopper

With batch certificate

Cat. No.: Capacity ml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

21 678 07 04 5 0.025 70 22 7/16 7 ± 1 2

21 678 08 07 10 0.025 90 27 7/16 7 ± 1 2

21 678 12 03 20 0.04 110 39 10/19 9 ± 1 2

21 678 14 09 25 0.04 110 40 10/19 9 ± 1 2

21 678 17 09 50 0.06 140 50 12/21 11 ± 1 2

21 678 24 05 100 0.1 170 60 12/21 13 ± 1 2

21 678 25 08 100 0.1 170 60 14/23 13 ± 1 2

21 678 32 04 200 0.15 210 75 14/23 15.5 ± 1.5 2

21 678 36 07 250 0.15 220 80 14/23 15.5 ± 1.5 2

21 678 44 06 500 0.25 260 100 19/26 19 ± 2 2

21 678 54 02 1000 0.4 300 125 24/29 23 ± 2 2

21 678 63 04 2000 0.6 370 160 29/32 27.5 ± 2.5 2

21 678 73 09 5000 1.2 475 215 34/35 38 ± 3 1

Cat. No.: Capacityml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 677 09 55 5w1 0.04 70 22 10/19 9 ± 1 2

24 677 10 51 10w1 0.04 90 27 10/19 9 ± 1 2

24 677 12 57 20 0.04 110 39 10/19 9 ± 1 2

24 677 14 54 25 0.04 110 40 10/19 9 ± 1 2

24 677 17 54 50 0.06 140 50 12/21 11 ± 1 2

24 677 24 59 100 0.1 170 60 12/21 13 ± 1 2

24 677 25 53 100 0.1 170 60 14/23 13 ± 1 2

24 677 32 58 200 0.15 210 75 14/23 15.5 ± 1.5 2

24 677 36 52 250 0.15 220 80 14/23 19 ± 2 2

24 677 44 51 500 0.25 260 100 19/26 23 ± 2 2

24 677 54 56 1000 0.4 300 125 24/29 27.5 ± 2.5 2

24 677 63 58 2000 0.6 370 160 29/32 38 ± 3 2

Page 9: Extensive range. Proven design. - Euro-Glas

16 17 DURan® volUmeTRic flask, class b

white graduation, with one graduation mark and new ergonomic polyethylene stopper

w1 – wide neck

DURan® volUmeTRic flask, ambeR, class a

white graduation, with one graduation mark and new ergonomic polyethylene stopper

Certificate of conformity "H"

With batch certificate

w1 – wide neck

Cat. No.: Capacity ml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 676 09 54 5w1 0.04 70 22 10/19 9 ± 1 2

24 676 10 59 10w1 0.04 90 27 10/19 9 ± 1 2

24 676 12 56 20 0.04 110 39 10/19 9 ± 1 2

24 676 14 53 25 0.04 110 40 10/19 9 ± 1 2

24 676 17 53 50 0.06 140 50 12/21 11 ± 1 2

24 676 24 58 100 0.1 170 60 12/21 13 ± 1 2

24 676 25 52 100 0.1 170 60 14/23 13 ± 1 2

24 676 32 57 200 0.15 210 75 14/23 15.5 ± 1.5 2

24 676 36 51 250 0.15 220 80 14/23 19 ± 2 2

24 676 44 59 500 0.25 260 100 19/26 23 ± 2 2

24 676 54 55 1000 0.4 300 125 24/29 27.5 ± 2.5 2

24 676 63 57 2000 0.6 370 160 29/32 38 ± 3 2

Cat. No.: Capacity ml

Accuracy limit ± ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Inner neck diameter

mm

Packaging unit

24 670 09 57 5w1 0.08 70 22 10/19 9 ± 1 2

24 670 10 53 10w1 0.08 90 27 10/19 9 ± 1 2

24 670 12 59 20 0.08 110 39 10/19 9 ± 1 2

24 670 14 56 25 0.08 110 40 10/19 9 ± 1 2

24 670 17 56 50 0.12 140 50 12/21 11 ± 1 2

24 670 25 55 100 0.2 170 60 14/23 13 ± 1 2

24 670 32 51 200 0.3 210 75 14/23 15.5 ± 1.5 2

24 670 36 54 250 0.3 220 80 14/23 15.5 ± 1.5 2

24 670 44 53 500 0.5 260 100 19/26 19 ± 2 2

24 670 54 58 1000 0.8 300 125 24/29 23 ± 2 2

24 670 63 51 2000 1.2 370 160 29/32 27.5 ± 2.5 2

24 670 73 56 5000 2.4 475 215 34/35 38 ± 3 1

Page 10: Extensive range. Proven design. - Euro-Glas

d

h

18 19DefiniTive laseR maRking fRom DURan®: RUling oUT mix-Ups

Volumetric flasks can be marked permanently in the description field without damaging the glass. This

allows errors to be avoided when performing routine tasks. in addition, the vessels can be integrated

automatically into the complete workflow using a scanner, saving time and money.

The font size is predefined and the contents can be selected freely: markings can include barcodes,

serial numbers, texts, digits or logos. This is even possible regardless of the order quantity. The service

therefore applies equally to small and large batches.

for more information, please visit www.duran-group.com/lasermarking

DURan® measURing cylinDeRs: Two applicaTions in one

DURan® measuring cylinders are used for holding and simultaneously

measuring different amounts of liquid. The tolerances of the measuring and

mixing cylinders in relation to the capacity correspond to the accuracy limits

under DIN and ISO. The batch certificates for the measuring cylinders are

enclosed with the product and are also available online.

DURan® measURing cylinDeR, class a

blue graduation, with main points ring graduation, hexagonal base

Certificate of conformity "H"

With batch certificate

Sample layout of a laser marked description field

Description field without laser marking

Description field with laser marking

Cat. No.: Capacity ml

Accuracy limit ± ml

Graduation divisions

ml

Overall heighth mm

Outer diameter

d mm

Packaging unit

21 390 07 01 5 0.05 0.1 112 12 2

21 390 08 04 10 0.10 0.2 137 14 2

21 390 14 06 25 0.25 0.5 167 21 2

21 390 17 06 50 0.5 1 196 25 2

21 390 24 02 100 0.5 1 256 29 2

21 390 36 04 250 1 2 331 39 2

21 390 44 03 500 2.5 5 360 53 2

21 390 54 08 1000 5 10 460 65 1

21 390 63 01 2000 10 20 500 85 1

Page 11: Extensive range. Proven design. - Euro-Glas

20 21

DURan® mixing cylinDeR class a

blue graduation, with main points ring graduation, new ergonomic polyethylene stopper and

hexagonal base

Certificate of conformity "H"

With batch certificate

DURan® measURing cylinDeR, class b

white line graduation, hexagonal base

DURan® mixing cylinDeR: cReaTing compoUnDs

DURan® mixing cylinders are used for diluting solutions and mixing several

components in a given quantity ratio. The tolerances of the measuring and

mixing cylinders in relation to the capacity correspond to the accuracy limits

under DIN and ISO. The batch certificates for the mixing cylinders are

enclosed with the product and are also available online.

Cat. No.: Capacity ml

Accuracy limit ± ml

Graduation divisions

ml

Overall heighth mm

Outer diameter

d mm

Packaging unit

21 396 07 07 5 0.1 0.1 112 12 2

21 396 08 01 10 0.2 0.2 137 14 2

21 396 14 03 25 0.5 0.5 167 21 2

21 396 17 03 50 1 1 196 25 2

21 396 24 08 100 1 1 256 29 2

21 396 36 01 250 2 2 331 39 2

21 396 44 09 500 5 5 360 53 2

21 396 54 05 1000 10 10 460 65 1

21 396 63 07 2000 20 20 500 85 1

Cat. No.: Capacity ml

Accuracy limit± ml

Graduation divisions

ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Packaging unit

24 618 08 56 10 0.10 0.2 156 14 10/19 2

24 618 14 58 25 0.25 0.5 190 21 14/23 2

24 618 17 58 50 0.5 1 222 25 19/26 2

24 618 24 54 100 0.5 1 287 29 24/29 2

24 618 36 56 250 1 2 363 39 29/32 2

24 618 44 55 500 2.5 5 395 53 34/35 2

24 618 54 51 1000 5 10 500 65 45/40 1

24 618 63 53 2000 10 20 540 85 45/40 1

Page 12: Extensive range. Proven design. - Euro-Glas

h d1

d2

DURANPE

24/29

PE 04

1 2 3 4 5 6 7 8 9

10

11 12

1 31 2 3

4 5 6 7 8 9 10

11

12

1 3

PE 04

h d1

d2

DURANPE

24/29

PE 04

1 2 3 4 5 6 7 8 9

10

11 12

1 31 2 3

4 5 6 7 8 9 10

11

12

1 3

PE 04

h d1

d2

DURANPE

24/29

PE 04

1 2 3 4 5 6 7 8 9

10

11 12

1 31 2 3

4 5 6 7 8 9 10

11

12

1 3

PE 04

h d1

d2

DURANPE

24/29

PE 04

1 2 3 4 5 6 7 8 9

10

11 12

1 31 2 3

4 5 6 7 8 9 10

11

12

1 3

PE 04

h d1

d2

DURANPE

24/29

PE 04

1 2 3 4 5 6 7 8 9

10

11 12

1 31 2 3

4 5 6 7 8 9 10

11

12

1 3

PE 04

22 23DURan® mixing cylinDeR class b

white line graduation, polyethylene octagonal stopper and hexagonal base

DURan® polyeThylene sToppeR: exTRemely pRacTical solUTion

DURan® polyethylene stoppers are ergonomically shaped, therefore guaranteeing simple and secure

opening and closing of volumetric fl asks, mixing cylinders and reagent bottles. In addition, a cone with

several ring grooved fl anges ensures optimal leak tightness. Differently coloured stopper inserts ensure

simple and fast assignment of the ns size. The colour code is identical to that of the removable keck™

clips. Batch certifi cates for the DURAN® polyethylene stoppers are available at www.duran-group.com.

batch time: production details at a glance

The batch time located underneath every stopper comprises two concentric circles. The inner circle

indicates the year of production and also has an arrow pointing to one of the digits in the outer circle,

which indicates the month of production, for example a 1 for the month of January. The text "pe04"

can also be found on the underside of each stopper, which is the material designation for polyethylene.

view from belowDimensions

Cat. No.: Capacity ml

Accuracy limit ± ml

Graduation divisions

ml

Overall heighth mm

Outer diameter

d mm

Stopper size NS

Packaging unit

21 618 08 01 10 0.2 0.2 156 14 10/19 2

21 618 14 03 25 0.5 0.5 190 21 14/23 2

21 618 17 03 50 1 1 222 25 19/26 2

21 618 24 08 100 1 1 287 29 24/29 2

21 618 36 01 250 2 2 363 39 29/32 2

21 618 44 09 500 5 5 395 53 34/35 2

21 618 54 05 1000 10 10 500 65 45/40 1

21 618 63 07 2000 20 20 540 85 45/40 1

Cat. No.: NS size Insert colour

Overall heighth mm

Outer diameter d1 mm

Outer diameter d2 mm

Packaging unit

29 205 02 01 7/16 blue 28 29.5 17.5 10

29 205 03 04 10/19 green 32 32.5 20 10

29 205 04 07 12/21 violet 35 36.5 22 10

29 205 06 04 14/23 yellow 38 40 25 10

29 205 07 07 19/26 blue 42 44.5 31 10

29 205 08 01 24/29 green 46 51.5 38 10

29 205 09 04 29/32 red 50 61 45.5 10

29 205 11 03 34/45 orange 54 71 54.5 1

29 205 12 06 45/40 brown 60 81.5 65.5 1

Page 13: Extensive range. Proven design. - Euro-Glas

DURAN Group GmbH

hattenbergstraße 10

D-55122 mainz

Tel. +49 6131 1445-4131

fax +49 6131 1445-4016

[email protected]

www.duran-group.com

6040

403

e 02

14 5

.0 b

a/sc

h pr

inte

d in

ger

man

y