F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m
W i n d o w sS 70
F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m
S 70 W i n d o w s
G e r m a n E n g i n e e r e d - S y s t e m s
1/1
50
0/1
0.0
5/D
AN
/79
01
9
3
F50/F60
Table of contents
Introduction 04 - 05
References 06
System F 50 07 - 38
System F 60 39 - 55
System S 70 Windows 56 - 66
The catalogue shows a digest only out of the complete product program!
4
A Bold Idea Turns Into Elegance
Today, largescale aluminium- and glass construction is highly appreciated. The demands on curtain-wall design are
correspondingly high. The GUTMANN curtain-Wall System F50/F60 fulfils all the requirements of modern architecture.
Whether vertical or sloped, single or multi-storey – aluminium-glass curtain-walls of graceful appearance
can be designed for high-rise buildings, according to the test certificate of ”ift” Rosenheim.
The floor plan can be straight or polygonal; the GUTMANN Curtain-Wall System F50/F60 is also suitable for
manufacturing of skylights, pyramids, domes and winter gardens.
In troduc t ion
Besides the illumination of the
working and living environment,
outer environmental influences are
shielded.
The GUTMANN F50/F60
curtain-Wall System is assigned to
Framework-Material Group 1 and
2.1, respectively, as per DIN 4108.
The design principle is convincingly
simple: Everything is the same!
Matching mullion and transom
cross-sections support an efficient
manufacturing process.
This ultimately reduces production
costs considerably.
The elimination of the need for
additional milling or attachments
at mullions and transoms
underlines the economy of design
additionally. Furthermore, the
homogeneity minimises cutting
waste and optimises warehouse
management.
5
In troduc t ion
HERMANN GUTMANN WERKE AG – The Right Choice for You!
Hermann Gutmann Werke AG, with its headquarters in Weissenburg/Bavaria, has been successful in the marketpla-
ce for more than sixty years and is known both nationally and internationally for its versatile system and industry
profiles. The Gutmann Group, with roughly 950 employees, focuses on the manufacturing and selling of aluminium
frames for windows, curtain-walls and facades, aluminium system profiles, aluminium industry profiles, aluminium
wire as well as aluminium composite panels for signs, outdoor advertising and display room construction.
The products manufactured by the Gutmann Group are mainly used in the construction industry and by architects
but also in the packaging, furniture, and automobile industries, machinery and electrical branches, advertising, con-
trolling/supervision systems, and interior design.
Thanks to its commitment to innovative research and development, Hermann Gutmann Werke AG is continuously
improving its performance and product quality.
6
7reduced sca le
F50/F60 Sys tem F50
The Mullion-Transom Curtain Wall
8 reduced sca le
F50/F60 Sys tem F50
Design Description
9reduced sca le
F50/F60 Sys tem F50
Detail of Mullion-Transom Joint Assembly
10 reduced sca le
F50/F60 Sys tem F50
Basic Principle of Drainage Waterremoval
11reduced sca le
F50/F60 Sys tem F50
Inserts in the Mullion Profiles from Commercially AvailableCross-Sections (See Single Profiles)
12 reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
13reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
14 reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
15reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
16 reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
17reduced sca le
F50/F60 Sys tem F50
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
18 reduced sca le
F50/F60 Sys tem F50
Standard Cross-Section Points
19reduced sca le
F50/F60 Sys tem F50
Cross-Section Points: Mullions
20 reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, Assembly Mullions
21reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, Corner Mullion
22 reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, Transom
23reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, Outer CornerVariable 0 - 10°
24 reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, Outer CornerVariable 10 - 30°
25reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, Outer CornerVariable on One Side 10 - 30°
26 reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, Inner CornerVariable 0 - 10°
27reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, Inner CornerVariable 15 - 30°
28 reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, MullionStructural Curtain Wall
29reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, EaveVariable Eave Point 10 - 50°, with Gutter
30 reduced sca le
F50/F60 Sys tem F50
Cross-Section Point, TransomInclined Glazing
31reduced sca le
F50/F60 Sys tem F50
Cross-Section Points, TransomRoof-Ridge Connection
32 reduced sca le
F50/F60 Sys tem F50
Assembly Example: Base Point
33reduced sca le
F50/F60 Sys tem F50
Assembly Example: Ceiling Attachment
34 reduced sca le
F50/F60 Sys tem F50
Semi SG - Curtain Wall
35reduced sca le
F50/F60 Sys tem F50
Optical SG - Curtain Wall
36 reduced sca le
F50/F60 Sys tem F50
Optical SG - Curtain Wall
37reduced sca le
F50/F60 Sys tem F50
Infosection Points of Steel/Wood - Construction
38 reduced sca le
F50/F60 Sys tem F50
Cross-Section Points on Wooden Structure
39reduced sca le
F50/F60 Sys tem F60
The Mullion-Transom Curtain Wall
40 reduced sca le
F50/F60 Sys tem F60
Design Description
41reduced sca le
F50/F60 Sys tem F60
Detail of Mullion-Transom-Joint Assembly
42 reduced sca le
F50/F60 Sys tem F60
Basic Principle of Drainage Water Removal
43reduced sca le
F50/F60 Sys tem F60
Insert into Mullion Profiles, from Standard Cross-Sections (See Single Profiles)
44 reduced sca le
F50/F60 Sys tem F60
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
45reduced sca le
F50/F60 Sys tem F60
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
46 reduced sca le
F50/F60 Sys tem F60
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
47reduced sca le
F50/F60 Sys tem F60
Profiles
The statical values listed have been verified electronically. The x-x Axis is valid when considered for stress through wind and imposed loading.
48 reduced sca le
F50/F60 Sys tem F60
Standard Cross-Section Points
49reduced sca le
F50/F60 Sys tem F60
Cross-Section Points: Mullions
50 reduced sca le
F50/F60 Sys tem F60
Cross-Section Points, Assembly Mullions
51reduced sca le
F50/F60 Sys tem F60
Cross-Section Point, Corner Mullion
52 reduced sca le
F50/F60 Sys tem F60
Cross-Section Point, Transom
53reduced sca le
F50/F60 Sys tem F60
Cross-Section Point, Outer CornerVariable 0 - 10°
54 reduced sca le
F50/F60 Sys tem F60
Cross-Section Points with Base Profil on Steel or Wooden Structure
55reduced sca le
F50/F60 Sys tem F60
Cross-Section Points with Base Profil on Steel or Wooden Structure
56 reduced sca le
S70 Sys tem S70 Window
Standard Cross-Section Points
57reduced sca le
S70 Sys tem S70 Window
Standard Detail Panel Window
58 reduced sca le
S70 Sys tem S70 Window
Standard Detail Panel Window
59reduced sca le
S70 Sys tem S70 Window
Standard Detail Panel Window
Elektronic drive230 V ACArt.-Nr. 64710901
60 reduced sca le
S70 Sys tem S70 Window
Consealed Window
S70 Sys tem S70 Window
61reduced sca le
Consealed Window - Exportversion
62 reduced sca le
S70 Sys tem S70 Window
Consealed Window
63reduced sca le
S70 Sys tem S70 Window
Cross-Section Point: Dormer Window Upper
64 reduced sca le
S70 Sys tem S70 Window
Cross-Section Point: Dormer Window Lower
65reduced sca le
S70 Sys tem S70 Window
Main Door Opening Inside
66 reduced sca le
Sys tem S70 WindowS70
Cross-Section Point: Wood-Aluminium Panel Window
P R O D U C T C ATA L O G U E
PR
OD
UC
T C
AT
AL
OG
UE
H E R M A N N G U T M A N N W E R K E AG • N u e r n b e rg e r S t r. 57- 81 • 91781 We i s s e n b u rg • G e r m a n y
Ph o n e : + 49 ( 0 ) 9141 / 992 - 0 • Fa x : + 49 ( 0 ) 9141 / 992 -212 • e m a i l : i n f o @ g u t m a n n . d e • w w w. g u t m a n n . d e
GU
TM
AN
N
F5
0/F
60
/ S
70
F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m
W i n d o w sS 70
F 50 / F 60 C u r t a i n - W a l l W i t h A S y s t e m
S 70 W i n d o w s
G e r m a n E n g i n e e r e d - S y s t e m s
1/1
50
0/1
0.0
5/D
AN
/79
01
9