FACILITIES PROGRAM – PHASE IA USF Polytechnic IX. Program Tabulation and Description Phase IA - PECO Funding A. Program Table Summary Area Name Proposed NSF CR Classroom 5,000 TL Teaching Lab 27,548 SY Study 5,010 RL Research Lab 1,250 OC Office/Computer 13,923 IM Instructional Media 4,000 CS Campus Support 0 OA Other Assignable 0 Student Student Areas 0 SUBTOTAL 56,731 Shell Shell Space 0 GRAND TOTAL 56,731 USF Polytechnic – Phase IA 7/28/08 SECTION IX 62

Upload: vanthuy

Post on 01-Apr-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

IX. Program Tabulation and DescriptionPhase IA - PECO Funding

A. Program Table Summary

Area NameProposedNSF

CR Classroom 5,000TL Teaching Lab 27,548SY Study 5,010RL Research Lab 1,250OC Office/Computer 13,923IM Instructional Media 4,000CS Campus Support 0OA Other Assignable 0Student Student Areas 0SUBTOTAL 56,731

Shell Shell Space 0

GRAND TOTAL 56,731

USF Polytechnic – Phase IA 7/28/08SECTION IX

62

Page 2: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

B. Program Area Tabulation and Description

Project Name: USF Polytechnic - Phase IA PECO FundingDepartment Name: Classroom Commons

No. Description Number of stations NSF/Station Space Area No. Spaces Total Area Total Stations

CR1 Classroom - Large 100 25 2500 2 5000 200CR Classroom Subtotal 5000 200

TL1 IT Teaching Lab 24 38 912 2 1824 48TL2 Eng Teaching Lab 12 76 912 2 1824 24TL3 Eng Lab Storage 1 350 350 1 350 1TL4 Phys Sciences T.L. 25 54 1350 2 2700 50TL5 Phys Sci. Lab Prep. 2 675 1350 1 1350 2TL6 Collaborative Learning 50 25 1250 15 18750 750TL7 Networking Lab 25 30 750 1 750 25

TL Teaching Lab Subtotal 27548 900

SY1 Writing Center 3 40 120 1 120 3SY2 TLT Storage 1 100 100 1 100 1SY3 Shared Work Commons 8 100 800 1 800 8SY4 Shared Work Room 2 75 150 1 150 2SY5 Library Storage 2 150 300 1 300 2SY6 Special Collections 3 100 300 1 300 3SY7 Learning Commons 90 36 3420 1 3420 90

SY Study Subtotal 5010 109

RL1 IT Research Lab 2 125 250 5 1250 10RL Research Lab Subtotal 1250 10

Classroom Commons Total 38808 1219

USF Polytechnic – Phase IA 7/28/08SECTION IX

63

Page 3: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

Department Name: Academic Commons

No. Description Number of Stations NSF/Station Space Area No. Spaces Total Area Total Stations

OC1 Receptionist 2 150 300 1 300 2OC2 Workroom 8 60 480 1 480 8OC3 Meeting Room 10 20 200 1 200 10OC4 Administrator/AVP 1 250 250 1 250 1OC5 Special Assistant 1 130 130 1 130 1OC6 Trash Room 1 100 100 3 300 3OC7 Library Offices 3 125 375 1 375 3OC8 TLT Offices 2 205 410 1 410 2OC9 Resource Room 1 250 250 1 250 1OC10 Career Center 1 120 120 1 120 1OC11 Student Disability 1 120 120 1 120 1OC12 Academic Commons 46 178 8188 1 8188 46OC13 Admissions/Fin Aid 1 200 200 1 200 1OC14 Admissions 1 150 150 1 150 1OC15 Cashier 1 210 210 1 210 1OC16 Financial Aid 1 150 150 1 150 1OC17 Recruitment 1 150 150 1 150 1OC18 Testing/Evaluation 1 200 200 1 200 1OC19 Photo Identification 1 110 110 1 110 1OC20 Advisor Office 1 130 130 1 130 1OC21 File Storage 1 300 300 1 300 1OC22 Campus Server Room 6 200 1200 1 1200 6

OC Office Computer Subtotal 13923 94

Department Name: Academic and Campus Support Areas

No. Description Number of Stations NSF/Station Space Area No. Spaces Total Area Total Stations

IM1 Audio Editing Room 2 80 160 1 160 2IM2 Central Machine Core 4 250 1000 1 1000 4IM3 Production Control 5 200 1000 1 1000 5

USF Polytechnic – Phase IA 7/28/08SECTION IX

64

Page 4: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

IM4 Audio Recording 2 40 80 1 80 2IM5 Equipment Check 2 300 600 1 600 2IM6 Video Editing Room 2 80 160 1 160 2IM7 Instructional TV Lab 40 25 1000 1 1000 40

IM Instructional Media Subtotal 4000 57

CS Campus Support Subtotal 0 0

OA Other Assignable Subtotal 0 0

Academic and Campus Support Subtotal 4000 57

Department: Common Areas

No. Description Number of stations NSF/Station Space Area No. Spaces Total Area Total StationsCategory or Dept. Non-Assignable

NA1 Lobby 16 45 720 1 720 16NA2 Toilet (Men or Women) 6 50 300 6 1800 36NA3 Housekeeping Closets 1 80 80 3 240 3NA4 Housekeeping Storage 1 320 320 1 320 1NA5 Communications Closet 1 100 100 3 300 3NA6 Building Systems 1 400 400 3 1200 3NA7 Elevator & Equipment 10 80 800 3 2400 30NA8 Corridors 0 0 0NA9 Lobby/Reception 1 500 500 1 500 1NA10 Campus Server 2 100 200 1 200 2NA11 Server Room IDF 2 100 200 1 200 2NA12 Building Floor IDF 2 50 100 3 300 6NA13 Building MDF 2 100 200 1 200 2NA14 Wireless Distribution 1 80 80 1 80 1

NA Non-Assignable

PECO TOTAL 56731 1370

USF Polytechnic – Phase IA 7/28/08SECTION IX

65

Page 5: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

C. Space Description Forms

Space Description Form _CR-1____

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: LARGE COLLABORATIVE LEARNING SPACE (dividable into two equal

sections) DESCRIPTION / USE: Collaborative learning SUS SPACE CATEGORY: Classroom ROOM USE CODE: 110 PERSONNEL ASSIGNED / MAX.: 200 (100 in each half) DIMENSION / AREA: 2500 NSF NUMBER REQUIRED: 2RELATIONSHIP TO OTHER AREAS

Other Classrooms

PRIMARY: Learning

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Per university standards WALLS: Comply with university standards CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: Solar control for darkening the rooms LIGHTING: Natural light and low energy light fixtures ACOUSTICAL: Very goodMECHANICAL CRITERIA HVAC: Yes, limiting noise in the classroom PLUMBING: No DATA/COMMUNICATIONS: Wireless data, phone, electric throughout on the floor to accommodate laptop

computers. Cameras and microphones for recording classes and video conferencing. Ceiling mounted projector, sound and speakers, and electronically controlled ceiling mounted screen in each half of the classroom.

ELECTRICAL: Per technology requirements and throughout the room from the floor to the table/desk top

FURNITURE/EQUIPMENT FURNITURE (OWNER): The furniture for this room needs to be rolling tables and chairs, movable to form a

variety of configurations, including rows, groups, and individual. In each configuration, there must be access to electrical sources for laptops. Chairs should have arms, be upholstered and stackable.

EQUIPMENT (OWNER): Desk level movable podium with computer, Elmo, video/DVD output. Smartboard/Sympodium technology in both halves of the classroom.

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR): Dividable wall to separate the space into two equal sections

USF Polytechnic – Phase IA 7/28/08SECTION IX

66

Page 6: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SUPPLEMENTAL INFORMATION/REQUIREMENTS

This room also needs the ability to broadcast to the smaller classrooms. (Connect through technology.)

Smart Teaching Podiums or work stations with PC and /or laptops; Symposium (if required); digital document camera; DVD player or VOD; wireless microphone for instructor; any other innovative required teaching tool.

Hanging microphones and audio wall taps are needed. One of the smaller classrooms must also be equipped as a self-contained Videoconference

room. (Same capabilities as the videoconference room listed in the Media Services Learning commons.

The rooms would have to either be raised flooring or be trenched to place all the wiring in the floor and have flush mounted cable floor boxes.

Crestron driven room technology for use with controlling all of the podium technology in the classrooms and controlling all the room lights; projector screen (if used); LCD screen (instead of projector screen & mounted projector).

Each classroom would need high bandwidth (10gig) cat 5/6 internet access. Each video feed would include: Cat 5/6; fiber; RF; HDMI All video feeds would originate and go

back to the Central Machine Core Room Each classroom should be equipped with a camera. All video feeds would originate and go back

to the Central Machine Core Room

Space Description Form _TL-1____USF Polytechnic – Phase IA 7/28/08SECTION IX

67

Page 7: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: INFORMATION TECHNOLOGY TEACHING LABS DESCRIPTION / USE: Flexible Computer Lab SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 24 DIMENSION / AREA: 912 NSF NUMBER REQUIRED: 2RELATIONSHIP TO OTHER AREAS PRIMARY: Connected to adjacent lab with collapsible wall

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Tile WALLS: Comply with university standards; wall adjacent to identical lab: collapsible CEILINGS: Acoustical DOORS: Solid Core Wood with glass window WINDOWS: Solar Control for darkening rooms LIGHTING: Natural and Low energy light fixtures ACOUSTICAL: Very goodMECHANICAL CRITERIA HVAC: Comply with University Standards PLUMBING: Non DATA/COMMUNICATIONS: Wireless data, phone, electric throughout on the floor to accommodate

laptop/desktops computers. Cameras and microphones for recording classes and video conferencing. Ceiling mounted projector, sound and speakers, and screen.

ELECTRICAL: Per technology requirements and throughout the room on the floor to meet all possible configurations of the room.

FURNITURE/EQUIPMENT FURNITURE (OWNER): The furniture for this room needs to be rolling tables and chairs, movable to form a

variety of configurations, including rows, groups, and individual. In each configuration, there must be access to electrical sources for laptops/desktops. A traditional computer lab with a much higher degree of flexibility.Chairs should have arms, be upholstered and stackable.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR): Desk level movable podium with computer, Elmo, video/DVD output. Smartboard

technology. Ceiling mounted projector, sound and speakers, and projection surface.

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _TL-2____USF Polytechnic – Phase IA 7/28/08SECTION IX

68

Page 8: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: ENGINEERING TEACHING LAB (MANUFACTURING AND ENVIRONMENTAL) DESCRIPTION / USE: Engineering Teaching Lab SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 12 Students/ 1 Instructor DIMENSION / AREA: 912 NSF NUMBER REQUIRED: 2 (connected by a double door)RELATIONSHIP TO OTHER AREAS PRIMARY:

Identical Lab SECONDARY: Storage Space (rear of 1 lab)

ARCHITECTURAL CRITERIA FLOORS: Tile WALLS: Comply with university standards; some sound-proofing CEILINGS: Acoustical tile DOORS: Solid core wood, with a glass window: Double doors(4): entry, connector to other

lab, connector to storage space, Sliders or pocket doors could also be considered. WINDOWS: LIGHTING: Low energy Light fixtures; leveled lighting ACOUSTICAL: Very goodMECHANICAL CRITERIA HVAC: Per code PLUMBING: 1 sink per lab DATA/COMMUNICATIONS: Wireless data, phone, electric throughout on the floor to accommodate laptop

computers. Cameras and microphones for recording classes and video conferencing. Ceiling mounted projector, sound and speakers, and screen.

ELECTRICAL: Per technology and equipment requirements – minimum of two 220V outlets FURNITURE/EQUIPMENT FURNITURE (OWNER): Custom desks for computer work – minimum of 12 work stations.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): Cabinetry/Casework along 1 wall to include sink.

EQUIPMENT (CONTRACTOR): Projection surface, white boards, moveable podium with electrical and data

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form __TL-3___

USF Polytechnic – Phase IA 7/28/08SECTION IX

69

Page 9: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: ENGINEERING LAB STORAGE ROOM DESCRIPTION / USE: Storage/Instruments SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 215 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 350 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY:

Connected by double doors to 1 Engineering Teaching Lab SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Tile WALLS: Comply with University Standards CEILINGS: Acoustical DOORS: Solid Core Wood, Double WINDOWS: None LIGHTING: Overhead/Fluorescent ACOUSTICAL:MECHANICAL CRITERIA HVAC: Comply with University Standards PLUMBING: None DATA/COMMUNICATIONS: None ELECTRICAL: Outlets per codeFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): Cabinets/Casework for storage of materials

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSMostly open space to store/roll large instruments when not in use.

Space Description Form _TL-4____USF Polytechnic – Phase IA 7/28/08SECTION IX

70

Page 10: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: PHYSICAL SCIENCES LAB DESCRIPTION / USE: Physical Sciences/interdisciplinary Lab SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 25 students/1 instructor DIMENSION / AREA: 1350 NSF NUMBER REQUIRED: 2RELATIONSHIP TO OTHER AREAS PRIMARY:

Storage/Prep Area b/n 2 Labs SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Seamless Lab Floor WALLS: Comply with University Standard CEILINGS: Acoustical Tile DOORS: Solid Core Wood with glass panel WINDOWS: All windows will need blinds to provide light control LIGHTING: Fluorescent Lighting ACOUSTICAL: Transfer of noise limitedMECHANICAL CRITERIA HVAC: Per code. Enhance ventilation to meet science lab requirements. Include individual

moveable ventilation cones above each work station. Also provide a vented demonstration (glass on both sides) Fume hood

PLUMBING: Per code. 4 sinks along the walls and 4 sink in center workstations Gas, Air, Water, Vacuum to chemical fume hood, center workstations and along walls.

DATA/COMMUNICATIONS: Wireless data, phone, electric throughout from the ceiling to accommodate laptop/desktops computers. Ceiling mounted projector, sound and speakers, and screen.

ELECTRICAL: Electric (grounded) from ceiling and in strips along walls. Electrical per fume hood requirement. At least 2 additional 220v outlets.

FURNITURE/EQUIPMENT FURNITURE (OWNER): Raised chairs to allow for seating at work tables.

Flammable storage cabinet.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): 6 stationary tables (seats 4) to include chemical resistant tops. Casework with

chemical resistant tops along the perimeter of the room with storage above and below. Casework with Chemical resistant tops in the center of the room to include 4 workstations. Glassware storage and drying racks. Demo/lecture table in the front of the room with electric, sink, air, gas, water, vacuum. Emergency shutoff at the demo table.

EQUIPMENT (CONTRACTOR): Demonstration Fume hood. (Glass on both sides.)Desk level podium with computer, Elmo, video/DVD output. Ceiling mounted projector, sound and speakers, and projection surface.

Space Description Form _TL-4____Description (Continued)USF Polytechnic – Phase IA 7/28/08SECTION IX

71

Page 11: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SUPPLEMENTAL INFORMATION/REQUIREMENTS All safety codes must be implemented for a chemistry/biology/physics/geology lab and all safety equipment

provided Heating and air conditioning will be provided with no air return to classrooms or other occupied spaces. Special consideration should be given to the placement of exhaust vents to maximize the effectiveness of

the exhaust system See pictures below for ideas for this space.

USF Polytechnic – Phase IA 7/28/08SECTION IX

72

Page 12: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

USF Polytechnic – Phase IA 7/28/08SECTION IX

73

Page 13: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

Space Description Form _TL-5____

USF Polytechnic – Phase IA 7/28/08SECTION IX

74

Page 14: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: PHYSICAL SCIENCES LAB PREP ROOM DESCRIPTION / USE: Physical Sciences/interdisciplinary Prep Room SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 215 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 1350 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY:

Storage/Prep Area b/n 2 Physical Sciences Lab SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Seamless Lab Floor WALLS: Comply with University Standard CEILINGS: Acoustical Tile DOORS: Split doors that open to both labs. Entry door from hall solid wood core with glass

window. Office seating area to be separated from prep area with glass wall and door.

WINDOWS: All windows will need blinds to provide light control LIGHTING: Fluorescent Lighting ACOUSTICAL: Transfer of noise limitedMECHANICAL CRITERIA HVAC: Per code. Enhance ventilation to meet science lab requirements. Also provide a

vented Fume hood. PLUMBING: Per code. 2 large sinks, gas, Air Water vacuum in case work along walls. Gas, Air,

Water, Vacuum to chemical fume hood. DATA/COMMUNICATIONS: Wireless data, phone. ELECTRICAL: Electric (grounded) in strips along walls. Electrical per fume hood requirement. At

least 2 additional 220v outlets.FURNITURE/EQUIPMENT FURNITURE (OWNER): Raised chairs (stools with backs) in the prep area; office chairs (2) in the office/desk

area.

EQUIPMENT (OWNER): Flammable storage cabinet(s)Refrigerator

FURNITURE (CONTRACTOR): Large shelved, lockable cabinets for chemical and material storage. Stationary shelving to store instruments. Casework with chemical resistant tops, with lockable storage. Workstations required to prep samples/chemicals. Desk, seating areas for 2 staff members to include data and electrical.

EQUIPMENT (CONTRACTOR): Dishwasher

SUPPLEMENTAL INFORMATION/REQUIREMENTS All safety codes must be implemented for a chemistry/biology/physics/geology lab and all safety equipment

provided Heating and air conditioning will be provided with no air return to classrooms or other occupied spaces. Prep/storage area to be separated from desk/office area by glass wall and door.

Space Description Form _TL-6____

USF Polytechnic – Phase IA 7/28/08SECTION IX

75

Page 15: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Classroom/Lab Commons AREA: Instructional SPACE NAME: COLLABORATIVE LEARNING SPACE (dividable into two equal sections) DESCRIPTION / USE: Collaborative learning SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 50 (25 in each half) DIMENSION / AREA: 1250 NSF NUMBER REQUIRED: 15 (30 half rooms)RELATIONSHIP TO OTHER AREAS

Other Teaching Labs

PRIMARY: Learning

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Per university standards WALLS: Comply with university standards; CEILINGS: Acoustical tile DOORS: Solid core wood, with a glass window WINDOWS: Solar control for darkening the rooms LIGHTING: Natural light and low energy light fixtures ACOUSTICAL: Very goodMECHANICAL CRITERIA HVAC: Yes, limiting noise in the classroom PLUMBING: No DATA/COMMUNICATIONS: Wireless data, phone, electric throughout on the floor to accommodate laptop

computers. Cameras and microphones for recording classes and video conferencing. Ceiling mounted projector, sound and speakers, and electronically controlled ceiling mounted screen in each half of the classroom.

ELECTRICAL: Per technology requirements and throughout the room on the floor to the table/desktop to meet all possible configurations of the room.

FURNITURE/EQUIPMENT FURNITURE (OWNER): The furniture for this room needs to be rolling tables and chairs, movable to form a

variety of configurations, including rows, groups, and individual. In each configuration, there must be access to electrical sources for laptops. Chairs should have arms, be upholstered and stackable.

EQUIPMENT (OWNER): Desk level movable podium with computer, Elmo, video/DVD output. Smartboard/Sympodium technology in both halves of the classroom.

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):Dividable wall to separate the space into two equal sections

SUPPLEMENTAL INFORMATION/REQUIREMENTS

USF Polytechnic – Phase IA 7/28/08SECTION IX

76

Page 16: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

Smart Teaching Podiums or work stations with PC and /or laptops; Sympodium (if required); digital document camera; DVD player or VOD; wireless microphone for instructor; any other innovative required teaching tool.

Hanging microphones and audio wall taps are needed. One of the smaller classrooms must also be equipped as a self-contained Videoconference

room. (Same capabilities as the videoconference room listed in the Media Services Learning commons.

The rooms would have to either be raised flooring or be trenched to place all the wiring in the floor and have flush mounted cable floor boxes.

Crestron driven room technology for use with controlling all of the podium technology in the classrooms and controlling all the room lights; projector screen (if used); LCD screen (instead of projector screen & mounted projector).

Each classroom would need high bandwidth (10gig) cat 5/6 internet access. Each video feed would include: Cat 5/6; fiber; RF; HDMI All video feeds would originate and go

back to the Central Machine Core Room Each classroom should be equipped with a camera. All video feeds would originate and go back

to the Central Machine Core Room

Classroom examples:

USF Polytechnic – Phase IA 7/28/08SECTION IX

77

Page 17: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

Note: Flexibility of furniture and classroom configuration. Space Description Form _TL - 7__

USF Polytechnic – Phase IA 7/28/08SECTION IX

78

Page 18: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Information Technology AREA: Instructional SPACE NAME: NETWORKING LABORATORY DESCRIPTION / USE: For hands-on instruction in networking hardware and software SUS SPACE CATEGORY: Teaching Lab ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 25 DIMENSION / AREA: 750 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Classrooms

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Tile or static-free carpeting; grounded wireless shield underneath WALLS: Wireless shielded CEILINGS: Acoustic tile, wireless shielded above DOORS: 36”, wireless shielded WINDOWS: None LIGHTING: Non-fluorescent (to avoid wireless emissions) ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: Heavy duty due to extensive electrical equipment use PLUMBING: None required DATA/COMMUNICATIONS: Defeatable wireless access point inside room; wall and floor socket connectors ELECTRICAL: Wall and floor sockets, multiple circuitsFURNITURE/EQUIPMENT FURNITURE (OWNER): Wheeled lab benches, stools

EQUIPMENT (OWNER): Wired and wireless equipment and simulation systems; TBD later FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSThis area will be used for student experimentation in wired and wireless networking. Experimentation in wireless networking requires that the space be shielded against stray wireless signals. A combination of hardwired and simulated networking equipment will be used, the exact nature of this equipment TBD closer to construction.

Space Description Form _SY-1____

USF Polytechnic – Phase IA 7/28/08SECTION IX

79

Page 19: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER

USF Polytechnic – Phase IA 7/28/08SECTION IX

80

Page 20: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: Arts & Sciences - English AREA: Academic SPACE NAME: WRITING CENTER DESCRIPTION / USE: Writing Center Consultation SUS SPACE CATEGORY: Study ROOM USE CODE: 410 PERSONNEL ASSIGNED / MAX.: 3 DIMENSION / AREA: 120 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Learning Commons

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Glass CEILINGS: Acoustical tile DOORS: Glass WINDOWS: LIGHTING: Indirect, uniform, controlled/flexible; some spot; low energy fixtures ACOUSTICAL: ControlledMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110V FURNITURE/EQUIPMENT FURNITURE (OWNER): Desk and Chair

Table and 2 ChairsBookcase

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _SY-2____

SPACE NUMBER

USF Polytechnic – Phase IA 7/28/08SECTION IX

81

Page 21: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: TLT AREA: Administrative SPACE NAME: TLT STORAGE DESCRIPTION / USE: Supplies/equipment for TLT SUS SPACE CATEGORY: Study ROOM USE CODE: 455 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 100 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Work Commons

SECONDARY: TLT Director/Offices

ARCHITECTURAL CRITERIA FLOORS: Tile Slip Resistant WALLS: Acoustical tile CEILINGS: DOORS: Solid WINDOWS: No LIGHTING: Controlled at entrance, low energy light fixtures ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wireless ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER): Shelving, cabinets

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _SY-3____

SPACE NUMBER USF Polytechnic – Phase IA 7/28/08SECTION IX

82

Page 22: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: Library/ERDC /TLT/Media (Shared) AREA: Administrative SPACE NAME: SHARED WORK COMMONS DESCRIPTION / USE: Shared office space, private consultation space and reception area SUS SPACE CATEGORY: Study ROOM USE CODE: 455 PERSONNEL ASSIGNED / MAX.: 8 DIMENSION / AREA: 800 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Office suites

SECONDARY: Learning Commons

ARCHITECTURAL CRITERIA FLOORS: carpet WALLS: CEILINGS: Acoustical tile DOORS: Full WINDOWS: LIGHTING: Indirect, uniform, controlled/flexible; some spot; low energy fixtures ACOUSTICAL: goodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110V wall and floor (recessed) mountedFURNITURE/EQUIPMENT FURNITURE (OWNER): 1 reception desk

Workstations + chairs

EQUIPMENT (OWNER): 7 computers, 1 LCD FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Commons area for offices (offices along walls?) – bullpen concept6 workstations for private consultations with faculty (≠ students)

Space Description Form _SY-4____

USF Polytechnic – Phase IA 7/28/08SECTION IX

83

Page 23: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER DEPARTMENT: Library/ERDC /TLT/Media (Shared) AREA: Administrative SPACE NAME: SHARED WORKROOM DESCRIPTION / USE: Photocopying, printing and kitchen area SUS SPACE CATEGORY: Study ROOM USE CODE: 455 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 150 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Work Commons SECONDARY: Office suitesARCHITECTURAL CRITERIA FLOORS: Tile slip resistant WALLS: CEILINGS: DOORS: WINDOWS: Solid wood with window LIGHTING: low energy fixtures ACOUSTICAL: controlledMECHANICAL CRITERIA HVAC: Yes PLUMBING: Yes DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110V ; 240VFURNITURE/EQUIPMENT FURNITURE (OWNER): Lockable storage cabinet

EQUIPMENT (OWNER): Photocopier/printer/fax/scanner, fridge, microwave FURNITURE (CONTRACTOR): Counter, sink, kitchen cabinet

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _SY-5__

USF Polytechnic – Phase IA 7/28/08SECTION IX

84

Page 24: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NUMBER

USF Polytechnic – Phase IA 7/28/08SECTION IX

85

Page 25: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: Library AREA: Administrative SPACE NAME: LIBRARY STORAGE DESCRIPTION / USE: Supplies/library storage SUS SPACE CATEGORY: Study ROOM USE CODE: 455 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 300 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Work Commons SECONDARY: Learning CommonsARCHITECTURAL CRITERIA FLOORS: Tile slip resistant WALLS: Acoustical tile CEILINGS: DOORS: solid WINDOWS: No LIGHTING: Controlled at entrance; low energy light fixtures ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wireless ELECTRICAL: 110V FURNITURE/EQUIPMENT FURNITURE (OWNER): Shelving, supplies cabinets

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _SY-6__

SPACE NUMBER

USF Polytechnic – Phase IA 7/28/08SECTION IX

86

Page 26: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: Library AREA: Academic SPACE NAME: SPECIAL COLLECTIONS DESCRIPTION / USE: Special Collections storage and processing SUS SPACE CATEGORY: Study ROOM USE CODE: 420 PERSONNEL ASSIGNED / MAX.: 3 DIMENSION / AREA: 300 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Learning Commons

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet; 6” raised WALLS: Glass and painted sheetrock CEILINGS: Acoustical tile DOORS: Glass WINDOWS: LIGHTING: Indirect, uniform, controlled/flexible; some spot; low energy fixtures ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110V wall and floor (recessed) mountedFURNITURE/EQUIPMENT FURNITURE (OWNER): Stacks

Tables (2) and chairs Desk and chair (1) Display case ?

EQUIPMENT (OWNER): Climate controlled incl. FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _SY-7__

SPACE NUMBER

USF Polytechnic – Phase IA 7/28/08SECTION IX

87

Page 27: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DEPARTMENT: Shared Learning Commons AREA: Academic SPACE NAME: LEARNING COMMONS DESCRIPTION / USE: Student Reading Room SUS SPACE CATEGORY: Study ROOM USE CODE: 410 PERSONNEL ASSIGNED / MAX.: 90 DIMENSION / AREA: 3240 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Work Commons SECONDARY: SGAARCHITECTURAL CRITERIA FLOORS: Carpet tile WALLS: Glass CEILINGS: Acoustical tile DOORS: Glass – main double door is sliding WINDOWS: Natural light; treatment; some view from offices into Learning Commons LIGHTING: Indirect, uniform, controlled/flexible; some spot; low energy fixtures ACOUSTICAL: controlledMECHANICAL CRITERIA HVAC: Additional capacity due to computers and equipment PLUMBING: Yes, for restroom DATA/COMMUNICATIONS: Wired and wireless data/phone. Showcased IDF closet w/ 2 rack capacity. Per tech

recommendations & University IT Specifications ELECTRICAL: 110V wall and floor (recessed) mounted per code. Provide power for each

workstation/seat. IDF requires 120/208V power access for UPSs and should be redundant via generator.

FURNITURE/EQUIPMENT FURNITURE (OWNER): Computer pods, tables, chairs, lounge chairs, end tables EQUIPMENT (OWNER): Staff computers (4), public computers), 4 printers (BW and color),

photocopier/scanner, security gates, library stacks (compact). LAN equipment wireless equipment

FURNITURE (CONTRACTOR): Custom desks w/ built-in wire management and power. EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Multi-use dynamic space with integrated technology (tables with computers, capacity for laptops, mobile laptop stations, mobile whiteboards)

Individual and group work space Public access workstations (5 computers) Info desk, (help desk), check out desk - 4 people – secure storage space (electronic access) Book drop in wall behind circulation desk One entrance point only – with other emergency-only exits, alarmed Public restrooms – handicapped accessible Lots of natural light Glass wall to interior lobby/corridor for showcasing Sightlines open from the help desk 12” drop floor in lab area PA System Workstations (60) spread out in clusters/pods Central will be copier/fax/scanner/printers

Space Description Form _RL - 1____

SPACE NUMBER DEPARTMENT: Information Technology

USF Polytechnic – Phase IA 7/28/08SECTION IX

88

Page 28: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Instructional SPACE NAME: IT RESEARCH LABORATORY DESCRIPTION / USE: For conducting faculty research projects SUS SPACE CATEGORY: Research Lab ROOM USE CODE: 250 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 250 NSF NUMBER REQUIRED: 5RELATIONSHIP TO OTHER AREAS PRIMARY: Academic Commons

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Tile or static-free carpet WALLS: 25% whiteboard, 25% shelving, 50% blank CEILINGS: Acoustic tile DOORS: 36” WINDOWS: None LIGHTING: Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: Heavy duty due to extensive electrical equipment use PLUMBING: None required DATA/COMMUNICATIONS: wall and floor socket connectors ELECTRICAL: Wall and floor sockets, multiple circuitsFURNITURE/EQUIPMENT FURNITURE (OWNER): Wheeled lab benches, stools, two desks

EQUIPMENT (OWNER): Two desktop systems per room FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSThese areas will be used for faculty research projects

Space Description Form _OC-1__

SPACE NUMBER DEPARTMENT: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

89

Page 29: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Support SPACE NAME: RECEPTIONIST DESCRIPTION / USE: SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 300 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Lobby

SECONDARY: Elevators

ARCHITECTURAL CRITERIA FLOORS: Match lobby WALLS: Match lobby CEILINGS: Match lobby DOORS: None WINDOWS: LIGHTING: Indirect, uniform, controlled/flexible (multi-bank) ACOUSTICAL: Match lobbyMECHANICAL CRITERIA HVAC: 15 CFM/Person outside air; standard 62-04 exhaust air PLUMBING: No DATA/COMMUNICATIONS: 4 data wired and wireless data/phone ELECTRICAL: Two quadruplex outletFURNITURE/EQUIPMENT FURNITURE (OWNER): 2 Custom desks with credenzas, 2 chairs

EQUIPMENT (OWNER): 2 Phones, 2 Computers, 1 Printer FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR): Computer

SUPPLEMENTAL INFORMATION/REQUIREMENTSFacing entry doors, located within lobby area

Space Description Form _OC-2__

SPACE NUMBER DEPARTMENT: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

90

Page 30: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Support SPACE NAME: WORKROOM DESCRIPTION / USE: Small workroom SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 315 PERSONNEL ASSIGNED / MAX.: 8 DIMENSION / AREA: 480 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Meeting room

SECONDARY: Corridor and reception

ARCHITECTURAL CRITERIA FLOORS: Vinyl tile WALLS: Gypsum board; full height lam. plastic backsplash CEILINGS: Suspended washable surfaces DOORS: Solid core wood WINDOWS: Treatment LIGHTING: 20 / 50 FC indirect 2 level switch ACOUSTICAL: NoneMECHANICAL CRITERIA HVAC: 15 CFM O.A per person required by Standard 62-04 PLUMBING: Bar sink DATA/COMMUNICATIONS: 2 locations: Voices: 4 CAT6 Data: 2 CAT6 TV outlet and wireless capability ELECTRICAL: 4 duplex outlets on each wall. 2 Computer duplex IG outletsFURNITURE/EQUIPMENT FURNITURE (OWNER):

Two tables (48” square); 8 stackable chairsTwo phones; coffee maker; full height 36” refrigeratorLaminate plastic cabinet – 7 ft. lower; 10 ft. upperMail Sorter with Base

EQUIPMENT (OWNER): Fax, Printer, Copier, Shredder, Postage Meter FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-3____

SPACE NUMBER DEPARTMENT: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

91

Page 31: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Support SPACE NAME: MEETING ROOM DESCRIPTION / USE: Small conference space open to CEO SUS SPACE CATEGORY: Office Computer ROOM USE CODE: 350 PERSONNEL ASSIGNED / MAX.: 10 DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: CEO Office

SECONDARY: Corridor

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Wainscot; acoustical upper surface CEILINGS: Acoustical DOORS: SC wood WINDOWS: Treatment and tinted LIGHTING: Natural light and low energy fixtures ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: 15 CFM/ person outside air; standard 62-04 exhaust air PLUMBING: No DATA/COMMUNICATIONS: 2 data/phone and wireless data ELECTRICAL: 2 quadruplex and multiple duplexFURNITURE/EQUIPMENT FURNITURE (OWNER):

Conference table; 10 Side chairs

EQUIPMENT (OWNER): One Digital Display Unit FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-4__

SPACE NUMBER DEPARTMENT: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

92

Page 32: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Support SPACE NAME: AVP/ADMINISTRATOR DESCRIPTION / USE: SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 250 NSF NUMBER REQUIRED: 2RELATIONSHIP TO OTHER AREAS PRIMARY: Special Assistant

SECONDARY: Other Offices

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: Solar control LIGHTING: Natural light and low energy light fixtures ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

Desk with credenza; two side chairs; office chair, bookcase, file cabinet, small oblong table, 6 visitor chairs

EQUIPMENT (OWNER): Computer, Laptop Computer, Printer, Phone FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-5__

SPACE NUMBER DEPARTMENT: Administration AREA: Support

USF Polytechnic – Phase IA 7/28/08SECTION IX

93

Page 33: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NAME: SPECIAL ASSISTANT DESCRIPTION / USE: SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 130 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: CEO and/or AVP

SECONDARY: Other Offices

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: Solar control LIGHTING: Natural light and low energy light fixures ACOUSTICAL: Good MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

Workstation (desk and table), chair, bookcase, file cabinet, small table, 2 visitor chairs

EQUIPMENT (OWNER): Computer, Printer, Scanner, Phone FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-6____

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: TRASH ROOM

USF Polytechnic – Phase IA 7/28/08SECTION IX

94

Page 34: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Trash disposal SUS SPACE CATEGORY: Office/Computer ROOM USE

CODE:315

PERSONNEL ASSIGNED / MAX.:

1

DIMENSION / AREA: 100 NSF NUMBER REQUIRED: 3RELATIONSHIP TO OTHER AREAS PRIMARY: Corridor SECONDARY: Academic Commons, Learning Commons and Classroom

Commons

ARCHITECTURAL CRITERIA FLOORS: Exposed WALLS: Gypsum board CEILINGS: Gypsum board DOORS: SC wood WINDOWS: LIGHTING: Vandal resistant ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Floor drain and hose bibb DATA/COMMUNICATIONS: ELECTRICAL: GFI duplex FURNITURE/EQUIPMENT FURNITURE (OWNER): Trash carts

EQUIPMENT (OWNER):

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-7___

SPACE NUMBER DEPARTMENT: Library AREA: Administrative SPACE NAME: LIBRARY OFFICE SUITE

USF Polytechnic – Phase IA 7/28/08SECTION IX

95

Page 35: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Offices SUS SPACE CATEGORY: Office Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 3 DIMENSION / AREA: 375 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Work Commons SECONDARY: Learning CommonsARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: CEILINGS: Acoustical tile DOORS: Solid wood WINDOWS: LIGHTING: Controlled at entry; spot lighting on desks; low energy fixtures ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110V FURNITURE/EQUIPMENT FURNITURE (OWNER): Director Faculty Staff

Desk, file cabinet, desk, file cabinet desk, file cabinetSeating for 2, bookcase seating for 1, bookcase seating for 1 Single-face Library stack Single-face Library stack

EQUIPMENT (OWNER): Phones, computers (5) FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-8__

SPACE NUMBER DEPARTMENT: Teaching and Learning Technologies AREA: Academic SPACE NAME: TLT SUITE

USF Polytechnic – Phase IA 7/28/08SECTION IX

96

Page 36: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Faculty development, technology integration SUS SPACE CATEGORY: Office Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 410 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Information/Learning Commons

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Comply with University Standards CEILINGS: Acoustical tile DOORS: Solid Core Wood WINDOWS: Aluminum Frame LIGHTING: Lighting shall be controlled at the entry to each space ACOUSTICAL: Per University StandardMECHANICAL CRITERIA HVAC: Per code PLUMBING: Per code DATA/COMMUNICATIONS: Wireless and hard wired data jacks (2 per each room) ELECTRICAL: Per codeFURNITURE/EQUIPMENT FURNITURE (OWNER): ? Director’s space 2 – GA space 1- support

Desk, Files, bookcase Double seating desks DeskSeating Bookcase File cabinet File cabinet Bookcase

EQUIPMENT (OWNER): ? 6 – Laptops, 6 Phones, Scanners (desktop) FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Appearance – open view between and amongst offices

Space Description Form _OC-9__

SPACE NUMBER DEPARTMENT: Student Affairs & Financial Aid/Admissions AREA: Administrative SPACE NAME: RESOURCE ROOM

USF Polytechnic – Phase IA 7/28/08SECTION IX

97

Page 37: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Provides shared workroom space for copier, fax, etc machines SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 315 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 250 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Student Affairs SECONDARY: Admissions/Financial Aid

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood with glass panels WINDOWS: Light control on all exterior windows LIGHTING: Low energy light fixtures ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): Small work table EQUIPMENT (CONTRACTOR): Copier, fax, scanner, mailboxesSUPPLEMENTAL INFORMATION/REQUIREMENTS

Shared space between Student Affairs and Student Academic Services – see space relationship bubble diagram

Space Description Form _OC-10__

SPACE NUMBER DEPARTMENT: Student Affairs AREA: Administrative SPACE NAME: CAREER CENTER OFFICE

USF Polytechnic – Phase IA 7/28/08SECTION IX

98

Page 38: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Staff member provides private, individual career counseling sessions for students SUS SPACE CATEGORY: Office Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 120 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY:

Student Health Services SECONDARY: Counseling Center

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: Light control on all exterior windows LIGHTING: Natural light & low energy light fixtures ACOUSTICAL: Better than normal acoustical so that privacy in maintained in counseling sessionsMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

Office desk & chairs & bookcase

EQUIPMENT (CONTRACTOR):Computer/printer/phone

SUPPLEMENTAL INFORMATION/REQUIREMENTS

If space is not available in the first Phase, one of the modular buildings would suffice for office space until such time that space is available. The staff member will be on campus part-time so office may be shared with other staff if needed.

Space Description Form _OC - 11__

SPACE NUMBER DEPARTMENT: Student Affairs AREA: Administrative SPACE NAME: STUDENT DISABILITY OFFICE

USF Polytechnic – Phase IA 7/28/08SECTION IX

99

Page 39: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Private office for staff member SUS SPACE CATEGORY: Office Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 120 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY:

Career Center SECONDARY: Counseling Center

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: Light control on all exterior windows LIGHTING: Natural light & low energy light fixtures ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

Desk & chairs

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

If space is not available in the Phase I, one of the modular buildings would suffice for office space until such time that space is available.

Space Description Form _OC-12__

SPACE NUMBER DEPARTMENT: Multiple AREA: Administrative SPACE NAME: ACADEMIC COMMONS DESCRIPTION / USE: Office, meeting, support & collaborative space for academic functions

USF Polytechnic – Phase IA 7/28/08SECTION IX

100

Page 40: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 46 (42 plus 4 adjuncts) DIMENSION / AREA: 8188 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Classroom and Information Commons

SECONDARY: Research Laboratories

ARCHITECTURAL CRITERIA FLOORS: Carpeting WALLS: Acoustically absorbent CEILINGS: Acoustically absorbent DOORS: See description WINDOWS: See description LIGHTING: Piped sunlight / soft fluorescents ACOUSTICAL: Acoustically absorbent, non-reflective surface where possibleMECHANICAL CRITERIA HVAC: Yes PLUMBING: Indoor DATA/COMMUNICATIONS: 10Gb wired; high data rate wireless, portable (wireless fallback) IP phones ELECTRICAL: Floor sockets for electrical and data. Wall sockets positioned for noninterference

with sliding doors. Ceiling sockets in collaborative area for installation of wireless access points ands other electronic equipment

FURNITURE/EQUIPMENT FURNITURE (OWNER): Chairs, meeting tables

EQUIPMENT (OWNER): Phones, computer systems, laptop docking stations, document storage/retrieval system, content preparation/delivery equipment suites, IP cameras, networking support equipment

FURNITURE (CONTRACTOR): Built-in faculty/staff desks, permanent shades/blinds, built-in equipment desks for course preparation/delivery areas

EQUIPMENT (CONTRACTOR): Lighting, data and electrical wiring, HVAC, plumbing

SUPPLEMENTAL INFORMATION/REQUIREMENTSSee Section IV – Introduction for descriptive narrative of Academic Commons space.

Space Description Form _OC - 13__

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: Admissions and Financial Aid SPACE NAME: ADMISSIONS AND FINANCIAL AID DESCRIPTION / USE: Provides oversight of student academic services excluding academic advising.

USF Polytechnic – Phase IA 7/28/08SECTION IX

101

Page 41: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS

Adjacent to Student Academic Services

PRIMARY: Director’s office

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid wood w/small glass panel WINDOWS: If possible include in design LIGHTING: To code ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: HOVFURNITURE/EQUIPMENT FURNITURE (OWNER): 1 desk w/chair; 2 side chairs; 1 small round table w/chairs; 2 bookcases; 2 filing

cabinets.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): Computer, printer, fax, phone and scanner.

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form __OC - 14_

SPACE NUMBER DEPARTMENT: Freshman Recruiter/Advisor AREA: Student Academic Services SPACE NAME: ADMISSIONS DESCRIPTION / USE: Freshman Admissions/Advising SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310

USF Polytechnic – Phase IA 7/28/08SECTION IX

102

Page 42: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 150 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS

Adjacent to Student Academic Services

PRIMARY:

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustic tile DOORS: Door w/glass panel WINDOWS: LIGHTING: ACOUSTICAL:MECHANICAL CRITERIA HVAC: PLUMBING: DATA/COMMUNICATIONS: ELECTRICAL:FURNITURE/EQUIPMENT FURNITURE (OWNER): 1 desk; 2 bookcases; 1 vertical three-drawer file cabinet;

1 small side table w/2 chairs. Office Chair; 2 side chairs.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

Computer; scanner; printer; fax; phone w/caller id.

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 15__

SPACE NUMBER DEPARTMENT: AdmissionsAREA: AdministrativeSPACE NAME: CashierDESCRIPTION / USE:SPACE CATEGORY: Office/Computer ROOM USE CODE: 210PERSONNEL ASSIGNED / MAX.: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

103

Page 43: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DIMENSION / AREA: 210 NSFNUMBER REQUIRED: 1RELATIONSHIPSPRIMARY:SECONDARY:ARCHITECTURAL CRITERIAFLOORS: CarpetWALLS: Comply with University standardsCEILINGS: Acoustical tileDOORS: Solid with small glass panel WINDOWS: All windows shall have horizontal or vertical blinds to provide light control.LIGHTING: Lighting shall be controlled from all entrances to each space. ACOUSTICAL: Per University standardsMECHANICAL CRITERIAHVAC: Per codePLUMBING: Per codeDATA/COMMUNICATIONS: Per Tech recommendations and University Information Technologies

Specifications.. 5 outlets in the cashier area. Two phonesELECTRICAL: Per code. Provide appropriate technology and power for cashier stations.FURNITURE/EQUIPMENTFURNITURE (OWNER): 2 stools (chairs)EQUIPMENT (OWNER): 2 phonesFURNITURE (CONTRACTOR): 2 cashier stations (1 Standard, 1 Handicapped)EQUIPMENT (CONTRACTOR): Outside drop boxSUPPLEMENTAL INFORMATION/REQUIREMENTS

Layout will determine need for either pass through window transactions or counter transactions.

Space Description Form _OC - 16__

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: Admissions and Financial Aid SPACE NAME: FINANCIAL AID DESCRIPTION / USE: Provides student intake & counseling for financial aid. SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

104

Page 44: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DIMENSION / AREA: 150 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS

Adjacent to Student Academic Services

PRIMARY:

Financial Aid Office SECONDARY:

Can be rotating to accommodate other uses.ARCHITECTURAL CRITERIA FLOORS: carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood w/glass panel WINDOWS: LIGHTING: ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL:FURNITURE/EQUIPMENT FURNITURE (OWNER):

1 desk and chair; 2 side chairs, 1 file cabinet and 1 bookshelf.

EQUIPMENT (OWNER):Computer, printer, scanner (Liberty), phone

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 17__

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: Admissions and Financial Aid SPACE NAME: RECRUITMENT DESCRIPTION / USE: Provides admissions information to new transfer and freshman students SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 150 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

105

Page 45: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS

Adjacent to recruitment orientation room and student academic services.

PRIMARY: Recruitment and Admission Advising

SECONDARY: Small group orientation

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock w/some windows CEILINGS: Acoustical tile DOORS: Solid wood w/small glass panel WINDOWS: LIGHTING: ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL:FURNITURE/EQUIPMENT FURNITURE (OWNER): 1 desk w/chair; 1 small table w/chairs (3); 1 filing cabinet, 2 bookshelves.

EQUIPMENT (OWNER): Computer, printer, scanner and phone

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 18__

SPACE NUMBER DEPARTMENT: AREA: Student Academic Services SPACE NAME: TESTING AND EVALUATION DESCRIPTION / USE: Provides testing area for students seeking admission and/or to satisfy university

requirement. SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 (part time)

USF Polytechnic – Phase IA 7/28/08SECTION IX

106

Page 46: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS

Adjacent to Student Academic Services

PRIMARY:Testing Center

SECONDARY:Classroom w/computers

ARCHITECTURAL CRITERIA FLOORS: carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood WINDOWS: LIGHTING: ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL:FURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER):10 computers; phone

FURNITURE (CONTRACTOR):Computer desks/tables/bookshelf1 desk/chair/sidechair1 computer for staff

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 19__

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: SPACE NAME: PHOTO ID LAB DESCRIPTION / USE: Production of Student Identification Cards SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 315 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 110 NSF NUMBER REQUIRED: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

107

Page 47: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

RELATIONSHIP TO OTHER AREAS

Adjacent to cashier’s office

PRIMARY:

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted Sheetrock CEILINGS: Acoustical tile DOORS: Solid wood w/small glass panel WINDOWS: LIGHTING: ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL:FURNITURE/EQUIPMENT FURNITURE (OWNER): 1 desk w/chair; 1 filing cabinet w/4 drawers; 1 chair w/o arms

EQUIPMENT (OWNER): Photo ID equipment including camera, computer, printer, background screen.

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 20__

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: Academic Advising SPACE NAME: ADVISOR OFFICE DESCRIPTION / USE: Academics advising for new & continuing transfer students. SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 310 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 130 NSF NUMBER REQUIRED: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

108

Page 48: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

RELATIONSHIP TO OTHER AREAS

Adjacent to student academic services

PRIMARY:

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid wood w/glass panel WINDOWS: LIGHTING: ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110VFURNITURE/EQUIPMENT FURNITURE (OWNER): 1 desk w/chair, 2 side chairs, 2 filing cabinets, 1 bookshelf.

EQUIPMENT (OWNER): 1 computer, printer, scanner and phone

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC - 21_

SPACE NUMBER DEPARTMENT: Student Academic Services AREA: Admissions and Financial Aid/Shared with Student Affairs SPACE NAME: FILE STORAGE DESCRIPTION / USE: SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 315 PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 300 NSF NUMBER REQUIRED: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

109

Page 49: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

RELATIONSHIP TO OTHER AREAS

Adjacent to Student Academic Services and Student Affairs

PRIMARY: Storage

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: DOORS: Solid wood w/small glass panel. WINDOWS: LIGHTING: ACOUSTICAL:MECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: YesFURNITURE/EQUIPMENT FURNITURE (OWNER): Filing system to be determined, mounted wall shelves

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): 2 chairs with wheels, 1 small table, 2 filing cabinets (metal w/lock), bookshelves

EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _OC-22_

SPACE NUMBER DEPARTMENT: ERDC AREA: Administration SPACE NAME: CAMPUS SERVER ROOM DESCRIPTION / USE: Campus Server Room SUS SPACE CATEGORY: Office/Computer ROOM USE CODE: 710 PERSONNEL ASSIGNED / MAX.: 6 DIMENSION / AREA: 1200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER

USF Polytechnic – Phase IA 7/28/08SECTION IX

110

Page 50: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREAS PRIMARY: Adjacent to ERDC offices, direct corridor access, Server electrical support room,

Server Room IDF

SECONDARY: Next to core IT support (MDF)

ARCHITECTURAL CRITERIA FLOORS: Raised floor (2’) for HVAC feed WALLS: Insulated wallboard covered in ½” plywood painted with fire retardant CEILINGS: Drop ceiling plenum for HVAC return DOORS: Double 4’ wide by 8’ tall doors, secured with keycard access

Standard door to ERDC office area, secured with keycard access WINDOWS: None LIGHTING: Standard Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: (2) Redundant dedicated HVAC units, down flow chilled water fed from redundant

water sources. Energy fed redundant via generator. Perforated floor tiles for distribution utilizing hot/cold aisle distribution technique.

PLUMBING: Floor drains only DATA/COMMUNICATIONS: Cable trays below drop ceiling encircling room and over racks ELECTRICAL: (2) 200A 120/208 3 phase power sources fed into (2) 75KW 3 ph UPSs from

campus server room electrical/UPS room, UPSs feed power distribution units and electricity is fed to each rack via overhead cable trays and flexible cabling.

FURNITURE/EQUIPMENT FURNITURE (OWNER): (24) total 42U enclosed server racks.

(2) Data Center grade downflow Airhandlers (water fed)(2) Electrical distribution cabinets fed from UPS banks

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSData Center.

Gas type primary fire suppression system with water pre action secondary.

Space Description Form _IM - 1__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: AUDIO EDITING ROOM DESCRIPTION / USE: Editing of audio soundtracks for the videos or podcasts needed for faculty

instruction, public relations projects, website videos SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 535 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 160 NSF NUMBER REQUIRED: 1

USF Polytechnic – Phase IA 7/28/08SECTION IX

111

Page 51: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

RELATIONSHIP TO OTHER AREAS PRIMARY: Voice over booth

SECONDARY: Video Edit boothARCHITECTURAL CRITERIA FLOORS: Raised with carpeted squares to absorb sound WALLS: Soundproofed for sound transfer; one half glass wall on hallway side (for viewing

tours); bright paint colors on wall CEILINGS: Armstrong or Sonex ceiling tiles for soundproofing DOORS: Solid core; secured keycard access WINDOWS: One half glass wall double panned window on hallway side LIGHTING: Regressed eyeball adjustable trim cans dimmable-switch by door entrance and

dimmable switch by edit table. Direct/Indirect lights; switchable from door entrance ACOUSTICAL: Soundproofed for sound transferMECHANICAL CRITERIA HVAC: Quiet return or supply for recording purposes PLUMBING: none DATA/COMMUNICATIONS: Cat 5/6 Wired data; VC unit phone; talkback station with small camera; AV taps

(HDMI-RF-SDI-VGA-Fiber) ELECTRICAL: 110/120V isolated/dedicated with UPS protection.FURNITURE/EQUIPMENT FURNITURE (OWNER): Editing table w 2 LCD monitors; equipment rack & HD rack; 1 lockable storage

cabinet ; 2 comfortable roller chairs; file cabinet; wall shelves

EQUIPMENT (OWNER): Editing software; high-end Media Center computer with large HD storage and DVD recorder with laser scribe; 2 LCD screens; small audio board; CD recorder/player; DAT recorder/player; digital videotape decks or recording HD; CD duplicator & printer; control room monitor speakers.

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSCable trays for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio3” cable conduits for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studioImportant that electrical runs and AV runs remain separated.

Space Description Form _IM - 2__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: CENTRAL MACHINE CORE DESCRIPTION / USE: This room will function as the central distribution & switching center and house all of

the central recording & duplication decks; media servers (hosting webscasting , VC, ITV classes-faculty classes-projects); PR web videos; special project videos); digital signage server & slaves; Videoconference units & content servers; campus wide signal feed distribution; distant site VBrick encoders-decoders; Crestron distribution switchers and any other equipment necessary for video switching or operations for

USF Polytechnic – Phase IA 7/28/08SECTION IX

112

Page 52: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

the campus. SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 530 PERSONNEL ASSIGNED / MAX.: 4 DIMENSION / AREA: 1000 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Production Control Room SECONDARY: TV StudioARCHITECTURAL CRITERIA FLOORS: Raised white floor tiles; WALLS: One portion of wall to have an Insulated wall board with ½” plywood painted with fire

retardant paint (for mounted amplifiers, splitters, terminated cable feeds); one half double panned window on hallway side (for viewing tours); walls must be soundproofed for noise levels so no machine noise bleeds into other areas; Sonex foam tiles placed on top half of wall to deaden the loud machine noise. Walls painted white.

CEILINGS: Armstrong or Sonex soundproof ceiling tiles DOORS: Solid core; keycard access WINDOWS: one half double panned window on hallway side (for viewing tours) LIGHTING: Direct/Indirect work lights with switch at entrance door. ACOUSTICAL: Sound proofMECHANICAL CRITERIA HVAC: Additional cooled air for the drastic heat levels that will be produced by multiple

machines. ( imperative that machines do not overheat for optimal functionality & warranties)

PLUMBING: none DATA/COMMUNICATIONS: High-bandwidth in/out; wired cat 5/6 data; wireless; talkback station; AV taps

(HDMI-SDI-VGA-Fiber-RF); 3 phones ELECTRICAL: 110V/120V/220V isolated/dedicated 3 phase with UPS protection.FURNITURE/EQUIPMENT FURNITURE (OWNER): 2 rolling chairs; 10 winsted equipment racks with rear panels for cable & equipment

entrance and work stations; 1 lockable storage cabinet; 1 file cabinet.

EQUIPMENT (OWNER): Media servers; VBrick encoder/decoders; videoconference codec & content server/ (3-4) 4panel LCD monitors at every work station (3); 4 LCD signal monitoring stations; encoding station; 4 computers.

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _IM - 3__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: PRODUCTION CONTROL CENTER DESCRIPTION / USE: To facilitate switching, recording and encoding of TV studio productions,

Instructional TV classroom and monitoring/switching videoconferences SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 535 PERSONNEL ASSIGNED / MAX.: 5 DIMENSION / AREA: 1000 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

113

Page 53: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: TV studio

SECONDARY: Central machine roomARCHITECTURAL CRITERIA FLOORS: Raised; WALLS: One-half double panned glass opening on hallway side (for viewing tours); main

wall adjacent to central machine room area; Acoustic absorbers on top half of walls to deaden noise levels

CEILINGS: Armstrong or Sonex ceiling tiles for sound proofing DOORS: (2) Solid core doors that lead into TV studio & into hallway; with keycard access on

hallway side WINDOWS: (2) One-half wall with double panned glass opening (for viewing tours) on hallway

side and one into the TV studio LIGHTING: Regressed eyeball adjustable trim cans with dimmable switch by door entrance and

by the control room console switching area ACOUSTICAL: Sound proof for sound transferMECHANICAL CRITERIA HVAC: Extra for the cooling of equipment that generates heat (and for the amount of bodies

present for long periods of time). PLUMBING: none DATA/COMMUNICATIONS: Wired cat 5/6 data; 5-6 phones( lines); talkback primary station; AV taps (HDMI-

SDI-VGA-Fiber) ELECTRICAL: 110v/120V isolated /dedicated with UPS protection; “On Air” light mounted outside

any entrance doorsFURNITURE/EQUIPMENT FURNITURE (OWNER): 5-6 rolling chairs; equipment racks EQUIPMENT (OWNER): equipment racks; TV studio digital (HD) video switcher; digital audio board;

graphics generator; DVE-Still store controller; 6 LCD monitors; ITV digital switcher; digital audio board; Videoconference (VC) switching.

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR): Special designed Control center console with multiple switching & monitoring

stations

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Cable trays for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio3” cable conduits for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio.Important that electrical runs and AV runs remain separated.“On Air” light mounted outside any door.

Space Description Form _IM - 4____

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: AUDIO RECORDING BOOTH DESCRIPTION / USE: Recording of vocal tracks used in the videos for faculty instruction, public relations

projects, website videos SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 530 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 80 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

114

Page 54: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Video Editing room

SECONDARY: Audio Editing roomARCHITECTURAL CRITERIA FLOORS: Raised with carpeted squares WALLS: Isolated/Soundproofed for sound transfer; walls covered in Sonex acoustical foam

absorbers & diffusers to deaden sound transfer for recording. CEILINGS: Sonex Alpha sculpted ceiling tiles; DOORS: Solid core with acoustical airtight door seals; secured keycard access WINDOWS: none LIGHTING: Canned regress eyeball adjustable trim can lights and Direct/Indirect lights work

lights; 2 separate switches that are switchable from door entrance and by recording board

ACOUSTICAL: Soundproofed for sound transferMECHANICAL CRITERIA HVAC: Quiet return or supply for recording purposes; possible isolation or no vents to keep

noise down. PLUMBING: none DATA/COMMUNICATIONS: Cat 5/6 Wired data; phone; audio talkback station; AV taps (RF-HDMI-SDI-VGA-

fiber); ELECTRICAL: 110/120V isolated/dedicated with UPS protectionFURNITURE/EQUIPMENT FURNITURE (OWNER): Recording table w audio recording decks; 1 lockable supply cabinet ; 2 comfortable

roller chairs; wall shelves

EQUIPMENT (OWNER): Digital audio board; CD recorder/player; DAT recorder/player; digital Hard drive recorder; control room monitor speakers; recording microphone with low cut filter; studio headphones

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSCable trays for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio3” cable conduits for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio

Important that electrical runs and AV runs remain separated.

Sonex acoustical foam room absorbers and bafflers for sound proofing and acousticsArmstrong or Sonex ceiling tiles for soundproofing

Space Description Form _IM - 5__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: EQUIPMENT CHECKOUT AND STORAGE ROOM DESCRIPTION / USE: To provide faculty and students with media/AV equipment checkout and media/AV

storage equipment area. SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 535 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 600 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

115

Page 55: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: All media services offices

SECONDARY: Unified Work Commons

ARCHITECTURAL CRITERIA FLOORS: Per code WALLS: Per code; one wall is a counter with a lockable cage screen for equipment checkout. CEILINGS: Per code DOORS: Solid core; keycard access WINDOWS: none LIGHTING: Direct/Indirect room lights with switch at door entrance ACOUSTICAL: Per codeMECHANICAL CRITERIA HVAC: Per code PLUMBING: none DATA/COMMUNICATIONS: Wired cat 5/6 data; wireless; 1 desk phone; AV taps (HDMI-Fiber-SDI-RF) ELECTRICAL: 110V/120V with UPS protectionFURNITURE/EQUIPMENT FURNITURE (OWNER): (1)workspace desk with lockable file; 1 chair with wheels; 1 large lockable file

cabinet ; multiple ceiling to floor wall mounted shelving to store equipment. EQUIPMENT (OWNER): (1)desktop computer or laptop with TV monitoring; all-in-one color printer

(scan/fax/copy/print); (1) large cork board; (1) large whiteboard (1) wall mounted LCD for Media system monitoring.

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _IM - 6__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: VIDEO EDITING ROOM DESCRIPTION / USE: Editing of video for the videos needed for faculty instruction, public relations

projects, website videos SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 530 PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 160 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

116

Page 56: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Voice over booth

SECONDARY: Audio Edit boothARCHITECTURAL CRITERIA FLOORS: Raised with carpeted squares to absorb sound WALLS: Soundproofed for sound transfer; one half double paned glass wall on hallway side

(for viewing tours); bright paint colors on wall CEILINGS: Armstrong or Sonex ceiling tiles for soundproofing DOORS: Solid core ; secured keycard access WINDOWS: one half double paned glass window on hallway side (for viewing tours) LIGHTING: Regressed eyeball adjustable trim cans dimmable-switch by door entrance and

dimmable switch by edit table. Direct/Indirect lights; switchable from door entrance ACOUSTICAL: Soundproofed for sound transferMECHANICAL CRITERIA HVAC: Quiet return or supply for recording purposes PLUMBING: none DATA/COMMUNICATIONS: Wired data; phone (VC unit); audio talkback station; AV taps; ELECTRICAL: 110/120V isolated/dedicated with UPS protectionFURNITURE/EQUIPMENT FURNITURE (OWNER): 6’ Editing table w equipment rack & HD rack; 1 lockable storage cabinet ; 2

comfortable roller chairs; file cabinet; wall shelves

EQUIPMENT (OWNER): HD Editing software; high-end Media Center computer with large HD storage and DVD recorder with laser scribe; 2 LCD screens; small audio board; CD recorder/player; DAT recorder/player; digital (HD) videotape decks or HD recording HD; DVD-CD duplicator & printer; control room monitor speakers; UPS unit.

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSCable trays for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studio3” cable conduits for AV runs from/to Central machine room, Production Control rooms, Video editing, audio booth & studioImportant that electrical runs and AV runs remain separated.

Space Description Form _IM - 7__

SPACE NUMBER DEPARTMENT: Instructional Media Services AREA: Media Services Suite SPACE NAME: INSTRUCTIONAL TV LAB DESCRIPTION / USE: For Instructional TV classes that provide webcasts and classes to other USF

campus and off site students. SUS SPACE CATEGORY: Instructional Media ROOM USE CODE: 210 PERSONNEL ASSIGNED / MAX.: 40 (with handicap access) DIMENSION / AREA: 1000 NSF

USF Polytechnic – Phase IA 7/28/08SECTION IX

117

Page 57: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Learning Commons

SECONDARY: Production Control RoomARCHITECTURAL CRITERIA FLOORS: Raised with carpeted squares; flush floor cable input boxes for podium operation. WALLS: Soundproofed for recording purposes; CEILINGS: Armstrong or Sonex tiles for soundproofing. DOORS: Solid core with viewing window; keycard access WINDOWS: none LIGHTING: Brightline dimmable lighting with control on Crestron wallplate at door entrance and

at instructors Crestron controller unit-podium; ACOUSTICAL: soundproofMECHANICAL CRITERIA HVAC: Special noiseless returns/supplies for recording purposes. PLUMBING: none DATA/COMMUNICATIONS: Wired Hi-bandwidth Cat 5/6; fiber; wireless; phone ( instructor podium); ELECTRICAL: 110V/120V isolated /dedicated with UPS protection; various flush (covered) floor

plugs for student laptop power.FURNITURE/EQUIPMENT FURNITURE (OWNER): Student movable tables & chairs; multi-media instructor multi-media podium w table

wing & chair; lockable storage cabinet in back of room.

EQUIPMENT (OWNER): (2) ceiling mounted 50” LCD monitors or (2) ceiling suspended 3M film plexiglass projection sheets (for student viewing) with (2) ceiling mounted projectors (1) back wall mounted 46” LCD confidence monitor(for faculty viewing); DVD player; Computer w LCD screen; wireless microphone; student ceiling microphones; surround sound room speakers; Crestron control unit; Crestron device switcher; room amp; (4) HD robotic cameras; digital document camera; Sympodium, cable cubby for laptop input.

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSBrightlines (dimmable) mounted in T-Bar ceilingsCrestron system devicesSmart Podium4 HD Robotic camerasCable trays for AV runs from/to Central machine room, Production Control rooms, ITV classroom3” cable conduits for AV runs from/to Central machine room, Production Control rooms, ITV classroomImportant that electrical runs and AV runs remain separated.

Following is a description of the space/service requirements of the Instructional Media Services area:Media Services provides support for all faculty classroom instruction, online instructional components, research, student and administrative staff on the USF Polytechnic campus as well as to its educational distant site partners. The Media Services area will be a component of the technical support commons where access to the USF Polytechnic faculty, students and staff will be facilitated. The primary offices of Media Services will be housed adjacent to the unified work commons areas so that the technical work areas can support one another. Additional facilities of Media Services will be located adjacent to the learning commons area for the convenience of students and faculty.

The Learning Commons Media rooms will include:

USF Polytechnic – Phase IA 7/28/08SECTION IX

118

Page 58: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

Instructional TV classroom (ITV) - This room will provide the faculty the opportunity to conduct and send live classes to the other USF campuses as well as via webcast with an encoded linkage in Blackboard.

Videoconference Room - This high end room will provide for faculty videoconferencing classes to the other USF campuses and other outlying educational site partners. The room would also provide administrative opportunities for videoconference meetings with other post-secondary education institutions and community partners, as well as providing the Lakeland Campus Board and the USF President a central Florida meeting place.

Equipment Storage and Checkout - This room will house all of the Media equipment for student and faculty checkout and also a storage area for all of the AV/Media equipment needed for the support of the entire campus operation.

The Work Commons area media rooms will include: The Media Services Offices- These offices will house all of the Media Services personnel needed for an

operation on a polytechnic campus. The Media Specialists will work in a collaborative environment for sharing innovative ideas, resolutions to issues and the monitoring of the campus media systems.

Central Machine Core Room - This room will be the operation center for the distribution (monitoring) of all the video/audio signals in and out of the campus and will house all of the central machines for recording, duplication, media servers, VBrick encoders/decoders, videoconference codecs/content servers, Crestron distribution, cable/satellite distribution, digital signage server & slaves, and any other equipment needed for distribution around the campus and to distant educational sites.

Editing Suites & Audio Recording Booth - These areas are for producing the final product of video shoots for faculty instructional projects and administrative special video projects. The audio recording booth & editing rooms will allow for the audio recording and mixing of soundtracks, podcasts, web announcements, radio shows and radio commercials. The video editing booth will allow for the final product editing of videos for faculty instruction for the classroom and online. Final video productions can also be produced for the web, podcasts, TV commercials, TV information shows, student news shows, public relations projects, and administrative special projects with community partners. The editing suite will also provide for interactive DVD production & duplication.

Production Control & TV studio - The production control room will provide the video switching, audio and graphics recording for the TV studio productions. This room will also provide the switching area for the Instructional TV classroom. The TV studio will be able to produce interactive videos for faculty instruction and other special projects.

TV Workroom & Storage - This room will provide for the storage of TV sets (backdrops), furniture and equipment for faculty instruction or special productions. This area will also be used for the building of these sets.

Space Description Form _NA-1__

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: LOBBY DESCRIPTION / USE: Reception SUS SPACE CATEGORY: Non-Assignable ROOM USE

CODE:WWW

PERSONNEL ASSIGNED / 16USF Polytechnic – Phase IA 7/28/08SECTION IX

119

Page 59: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

MAX.: DIMENSION / AREA: 720 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Conference room, break room, toilets, Learning Commons and

Classroom Commons SECONDARY: Academic Commons

ARCHITECTURAL CRITERIA FLOORS: Terrazzo WALLS: Gypsum wall board CEILINGS: Acoustical DOORS: SC wood WINDOWS: Storefront LIGHTING: Architectural ACOUSTICAL: Hanging panelsMECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Adjacent break sink DATA/COMMUNICATIONS: Wireless, four data/two phones ELECTRICAL: Two quadraplex, multiple duplexFURNITURE/EQUIPMENT FURNITURE (OWNER): Soft lounging furniture:

Four soft chairs, two sofas, coffee table and three side tables.One four-top with four side chairs.Track racks.Two desks and chairs.

EQUIPMENT (OWNER): Refrigerator.TV Monitor at Visitor Management Desk.

FURNITURE (CONTRACTOR): Reception desk and break counter Visitor Management Desk for sign-in/sign-out and security control

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

The space should be inviting for new visitors. Provide adequate signage for directions and adjacent break room.

Space Description Form _NA-2__

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: TOILET DESCRIPTION / USE: Toilet SUS SPACE CATEGORY: Non-Assignable ROOM USE

CODE:YWC

USF Polytechnic – Phase IA 7/28/08SECTION IX

120

Page 60: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

PERSONNEL ASSIGNED / MAX.:

6

DIMENSION / AREA: 300 NSF NUMBER REQUIRED: 6RELATIONSHIP TO OTHER AREAS PRIMARY: Janitor and reception SECONDARY: Academic Commons, Learning Commons and Classroom

Commons

ARCHITECTURAL CRITERIA FLOORS: Ceramic tile WALLS: Ceramic tile CEILINGS: Gypsum board DOORS: SC wood WINDOWS: Translucent LIGHTING: Vandal resistant ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Six toilets women, four toilets/two urinals men, four lavatories,

floor hose bibb, floor drains DATA/COMMUNICATIONS: Wireless ELECTRICAL: GFI duplexFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER):

FURNITURE (CONTRACTOR): Lavatory counter EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA-3__

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: HOUSEKEEPING CLOSETS DESCRIPTION / USE: Storage of cleaning items; sink for housekeeping use SUS SPACE CATEGORY: Non-Assignable ROOM USE XXX

USF Polytechnic – Phase IA 7/28/08SECTION IX

121

Page 61: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

CODE: PERSONNEL ASSIGNED / MAX.:

1

DIMENSION / AREA: 80 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Central location

SECONDARY: Toilets

ARCHITECTURAL CRITERIA FLOORS: Ceramic tile WALLS: Gypsum wall board CEILINGS: Gypsum board DOORS: SC wood WINDOWS: LIGHTING: Vandal proof ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Typical for housekeeping mop sink; floor drain DATA/COMMUNICATIONS: ELECTRICAL: GFI duplexFURNITURE/EQUIPMENT FURNITURE (OWNER): EQUIPMENT (OWNER): Mop hanger and hose

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA-4____

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: HOUSEKEEPING STORAGE DESCRIPTION / USE: Storage of cleaning items, stocking items, & maintenance tools

USF Polytechnic – Phase IA 7/28/08SECTION IX

122

Page 62: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE:

XXX

PERSONNEL ASSIGNED / MAX.:

1

DIMENSION / AREA: 320 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Corridor

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: VCT WALLS: Gypsum wall board CEILINGS: Acoustical DOORS: SC wood WINDOWS: LIGHTING: Troffers ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Floor drain; double work sink DATA/COMMUNICATIONS: Four data/two phones ELECTRICAL: Two GFI quadraplex, multiple GFI duplexFURNITURE/EQUIPMENT FURNITURE (OWNER): Staff desk and chair; workbench and stool. EQUIPMENT (OWNER): One computer CPU stations FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR): Sink accessories

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA-5__

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas SPACE NAME: COMMUNICATIONS CLOSETS

USF Polytechnic – Phase IA 7/28/08SECTION IX

123

Page 63: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

DESCRIPTION / USE: Communications equipment location SUS SPACE CATEGORY: Non-Assignable ROOM USE

CODE:YYE

PERSONNEL ASSIGNED / MAX.:

1

DIMENSION / AREA: 100 NSF NUMBER REQUIRED: 3RELATIONSHIP TO OTHER AREAS PRIMARY: Corridor

SECONDARY: Classroom, Academic & Learning Commons

ARCHITECTURAL CRITERIA FLOORS: VCT WALLS: Gypsum wall board CEILINGS: Acoustical DOORS: SC wood WINDOWS: LIGHTING: Troffers ACOUSTICAL:MECHANICAL CRITERIA HVAC: 64-75 dF; dedicated HVAC; 30-55% relative humidity PLUMBING: DATA/COMMUNICATIONS: 8’ x 10’ MDF; voice protectors; cross-connect panels; data; fiber

data cross-connect panels; CATV; protectors, splitters & amplifiers ELECTRICAL: 8’ x 10’ MDF; multiple IG quadraplex at 6’ OC at 84” AFF; 10’ x 7’

MDF voice; cross-connect panels; data; fiber data cross-connect panels

FURNITURE/EQUIPMENT FURNITURE (OWNER): EQUIPMENT (OWNER): FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA-6____

SPACE NUMBER DEPARTMENT: Support Spaces AREA: Common Areas

USF Polytechnic – Phase IA 7/28/08SECTION IX

124

Page 64: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NAME: BUILDING SYSTEMS DESCRIPTION / USE: Mechanical and Electrical building support spaces SUS SPACE CATEGORY: Non-Assignable ROOM USE

CODE:YYY

PERSONNEL ASSIGNED / MAX.:

1

DIMENSION / AREA: 400 NSF NUMBER REQUIRED: 3RELATIONSHIP TO OTHER AREAS PRIMARY: Corridor SECONDARY: Academic Commons, Learning Commons and Classroom

Commons

ARCHITECTURAL CRITERIA FLOORS: Exposed WALLS: Gypsum wall board CEILINGS: Gypsum board DOORS: SC wood WINDOWS: Translucent LIGHTING: Vandal resistant ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air PLUMBING: Floor drain

DATA/COMMUNICATIONS: Two data ports ELECTRICAL: Multiple GFI duplexFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER):

FURNITURE (CONTRACTOR): Plywood mounting for electrical equipment EQUIPMENT (CONTRACTOR): HVAC equipment

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA-7__

SPACE NUMBER DEPARTMENT: Support Spaces

USF Polytechnic – Phase IA 7/28/08SECTION IX

125

Page 65: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Common Areas SPACE NAME: ELEVATOR/ELEVATOR EQUIPMENT DESCRIPTION / USE: Elevator cab and equipment SUS SPACE CATEGORY: Non-Assignable ROOM USE

CODE:WWL

PERSONNEL ASSIGNED / MAX.:

10

DIMENSION / AREA: 800 NSF NUMBER REQUIRED: 3RELATIONSHIP TO OTHER AREAS PRIMARY: Corridor SECONDARY: Academic Commons, Learning Commons and Classroom

Commons

ARCHITECTURAL CRITERIA FLOORS: Ceramic tile WALLS: Laminate plastic in cab; gypsum board in shaft and equipment. CEILINGS: Translucent over stainless steel in cab; Gyp Bd. in equip room DOORS: SC wood WINDOWS: LIGHTING: Vandal resistant ACOUSTICAL:MECHANICAL CRITERIA HVAC: 15 CFM/person outside air ; Standard 62-04 exhaust air; NFPA

required exhaust in hoist way PLUMBING: None DATA/COMMUNICATIONS: Cab phone ELECTRICAL: GFI duplex and light in hoist way; lights in cabFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER):

FURNITURE (CONTRACTOR): Move-in pads EQUIPMENT (CONTRACTOR): Elevator equipment

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Three 4500 lb. rated elevators, each doubling as freight elevators Reverse door at first floor for freight access

Space Description Form _NA-8_

SPACE NUMBER DEPARTMENT:

USF Polytechnic – Phase IA 7/28/08SECTION IX

126

Page 66: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Support Spaces SPACE NAME: Common Areas DESCRIPTION / USE: Corridors SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: WWL PERSONNEL ASSIGNED / MAX.: n/a DIMENSION / AREA: Minimum 6 feet width NUMBER REQUIRED: n/aRELATIONSHIP TO OTHER AREAS PRIMARY:

SECONDARY:

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Gypsum Wall Board CEILINGS: Suspended Acoustical Tile DOORS: Solid Core Wood WINDOWS: LIGHTING: 20 foot candle Troffers ACOUSTICAL: CeilingMECHANICAL CRITERIA HVAC: Minimum 50 cubic feet per minute PLUMBING: DATA/COMMUNICATIONS: Data display at public areas; Minimum 24 inch cable tray in all corridors ELECTRICAL: Duplex at 25 feet on centerFURNITURE/EQUIPMENT FURNITURE (OWNER):

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA - 9_

SPACE NUMBER DEPARTMENT: Student Affairs & Financial Aid/Admissions

USF Polytechnic – Phase IA 7/28/08SECTION IX

127

Page 67: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Administrative SPACE NAME: LOBBY/RECEPTION DESCRIPTION / USE: Provides reception area for Student Affairs and Student Academic Services SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: WWW PERSONNEL ASSIGNED / MAX.: 1 DIMENSION / AREA: 500 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY:

Counseling Center SECONDARY: Career Center/Student Disability

ARCHITECTURAL CRITERIA FLOORS: Carpet WALLS: Painted sheetrock CEILINGS: Acoustical tile DOORS: Solid core wood with glass panels WINDOWS: Light control on all exterior windows LIGHTING: Natural light & low energy light fixtures ACOUSTICAL: GoodMECHANICAL CRITERIA HVAC: Yes PLUMBING: No DATA/COMMUNICATIONS: Wired and wireless data/phone ELECTRICAL: 110 VFURNITURE/EQUIPMENT FURNITURE (OWNER):

Receptionist desk, comfortable seating with small tables, 1 file cabinet and bookcase

EQUIPMENT (OWNER): Computer/printer/phone & copierKioskLCD Monitor – for information feed1 Multi-line telephone console for receptionist

FURNITURE (CONTRACTOR): EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Shared space with Student Academic Services – see space relationship bubble diagram

Space Description Form _NA-10_

SPACE NUMBER DEPARTMENT: ERDC

USF Polytechnic – Phase IA 7/28/08SECTION IX

128

Page 68: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Administration SPACE NAME: CAMPUS SERVER ROOM ELECTRICAL/UPS ROOM DESCRIPTION / USE: Campus Server Room Electrical/UPS Room SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: YYE PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Adjacent to ERDC campus server room, direct corridor access

SECONDARY: Next to core IT support (MDF, Server electrical support room)

ARCHITECTURAL CRITERIA FLOORS: Raised floor (2’) for HVAC feed WALLS: Insulated wallboard covered in ½” plywood painted with fire retardant CEILINGS: Drop ceiling plenum for HVAC return DOORS: Single 4’ wide by 8’ tall door, secured with keycard access

Single 4’ wide by 8’ tall door to Campus Server Room with keycard access WINDOWS: None LIGHTING: Standard Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: (2) Redundant dedicated HVAC units from campus server room, down flow chilled

water fed from redundant water sources. Energy fed redundant via generator. Perforated floor tiles for distribution utilizing hot/cold aisle distribution technique.

PLUMBING: Floor drains only DATA/COMMUNICATIONS: Cable trays below drop ceiling encircling room and over racks ELECTRICAL: (2) 200A 120/208 3 phase power sources fed into (2) 75KW 3 ph UPSs, UPSs feed

power distribution units and electricity is fed to each rack via overhead cable trays and flexible cabling.

FURNITURE/EQUIPMENT FURNITURE (OWNER): EQUIPMENT (OWNER): (2) Central UPS banks

FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSData Center.

Gas type primary fire suppression system with water pre action secondary.

Space Description Form _NA-11_

SPACE NUMBER DEPARTMENT: ERDC

USF Polytechnic – Phase IA 7/28/08SECTION IX

129

Page 69: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

AREA: Administration SPACE NAME: SERVER ROOM IDF DESCRIPTION / USE: Server Room IDF SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: YYE PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Adjacent to ERDC campus server room, direct corridor access

SECONDARY: Next to core IT support (MDF, Server electrical support room)

ARCHITECTURAL CRITERIA FLOORS: Raised floor (2’) for HVAC feed WALLS: Insulated wallboard covered in ½” plywood painted with fire retardant CEILINGS: Drop ceiling plenum for HVAC return DOORS: Single 4’ wide by 8’ tall door, secured with keycard access

Single 4’ wide by 8’ tall door to Campus Server Room with keycard access WINDOWS: None LIGHTING: Standard Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: (2) Redundant dedicated HVAC units from campus server room, down flow chilled

water fed from redundant water sources. Energy fed redundant via generator. Perforated floor tiles for distribution utilizing hot/cold aisle distribution technique.

PLUMBING: Floor drains only DATA/COMMUNICATIONS: Cable trays below drop ceiling encircling room and over racks ELECTRICAL: (2) 200A 120/208 3 phase power sources fed into (2) 75KW 3 ph UPSs, UPSs feed

power distribution units and electricity is fed to each rack via overhead cable trays and flexible cabling.

FURNITURE/EQUIPMENT FURNITURE (OWNER): (6) total 42U enclosed network racks.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA - 12__

SPACE NUMBER DEPARTMENT: ERDC AREA: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

130

Page 70: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NAME: BUILDING FLOOR IDF (MIN 1 PER FLOOR) DESCRIPTION / USE: Building Floor IDF SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: YYE PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 100 NSF NUMBER REQUIRED: 3RELATIONSHIP TO OTHER AREAS PRIMARY: Located each floor next central support core.

SECONDARY:ARCHITECTURAL CRITERIA FLOORS: Standard tile or concrete finish WALLS: Insulated wallboard covered in ½” plywood painted with fire retardant CEILINGS: Drop ceiling DOORS: Single 4’ wide by 8’ tall door, secured with keycard access WINDOWS: None LIGHTING: Standard Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: Additional HVAC for data/networking equipment PLUMBING: Floor drains only DATA/COMMUNICATIONS: Cable trays below drop ceiling encircling room and over racks ELECTRICAL: 120/208 3 phase power sources for UPS units fed by redundant Generator feed.FURNITURE/EQUIPMENT FURNITURE (OWNER): (3) total 42U enclosed network racks.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTSData Center.

Prefer stacked design (one on top of another)

Space Description Form _NA - 13__

SPACE NUMBER DEPARTMENT: ERDC AREA: Administration

USF Polytechnic – Phase IA 7/28/08SECTION IX

131

Page 71: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NAME: BUILDING MDF DESCRIPTION / USE: Building MDF SUS SPACE CATEGORY: Non-Assignable ROOM USE CODE: YYE PERSONNEL ASSIGNED / MAX.: 2 DIMENSION / AREA: 200 NSF NUMBER REQUIRED: 1RELATIONSHIP TO OTHER AREAS PRIMARY: Located on ground floor with direct corridor access. SECONDARY:ARCHITECTURAL CRITERIA FLOORS: Raised floor (2’) WALLS: Insulated wallboard covered in ½” plywood painted with fire retardant CEILINGS: Drop ceiling DOORS: Single 4’ wide by 8’ tall door, secured with keycard access WINDOWS: None LIGHTING: Standard Fluorescent ACOUSTICAL: n/aMECHANICAL CRITERIA HVAC: Additional HVAC for data/networking equipment redundant unit fed from generator PLUMBING: Floor drains only DATA/COMMUNICATIONS: Cable trays below drop ceiling encircling room and over racks, 4” conduits to IDFs

and outside plant access. ELECTRICAL: 120/208 3 phase power sources for UPS units fed by redundant Generator feed.FURNITURE/EQUIPMENT FURNITURE (OWNER):

(6) total 42U enclosed network racks.

EQUIPMENT (OWNER): FURNITURE (CONTRACTOR):

EQUIPMENT (CONTRACTOR):

SUPPLEMENTAL INFORMATION/REQUIREMENTS

Space Description Form _NA - 14__

SPACE NUMBER DEPARTMENT: ERDCAREA:

USF Polytechnic – Phase IA 7/28/08SECTION IX

132

Page 72: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

SPACE NAME: WIRELESS DISTRIBUTION ROOMDESCRIPTION / USE:SPACE CATEGORY: Non-Assignable ROOM USE CODE: YYEPERSONNEL ASSIGNED / MAX.: 1DIMENSION / AREA: 80 NSFNUMBER REQUIRED: 1RELATIONSHIPSPRIMARY: Roof top access via stairwell not ladder SECONDARY: Top floor IDFARCHITECTURAL CRITERIAFLOORS: No carpetWALLS: Comply with University standardsCEILINGS: Acoustical tileDOORS: Key card access. Main door is sliding double doorWINDOWS: NoneLIGHTING: Indirect lightingACOUSTICAL: Block noise going outMECHANICAL CRITERIAHVAC: Chilled air and secondary backup access, returned air ducks and

secondary vent with roof access for secondary HVACPLUMBING: Floor drain for HVAC secondaryDATA/COMMUNICATIONS: Per Tech recommendations and University Information Technologies

Specifications. Conduits directly to weatherproof roof access tubes and conduits feeding back to floors man IDF. Fiber optics connections on roof with protected power and lightning protection.

ELECTRICAL: 120/208V access for UPSs with redundant generator feedFURNITURE/EQUIPMENTFURNITURE (OWNER):EQUIPMENT (OWNER): LAN equipment

Wireless equipmentFURNITURE (CONTRACTOR):EQUIPMENT (CONTRACTOR):SUPPLEMENTAL INFORMATION/REQUIREMENTS

Used to distribute USF licensed software/hardware and give faculty staff students similar access to discounts as their Tampa counterparts

USF Polytechnic – Phase IA 7/28/08SECTION IX

133

Page 73: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

D. Space Relationship Diagrams

USF Polytechnic – Phase IA 7/28/08SECTION IX

134

Classroom/LabCommons

Page 74: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

USF Polytechnic – Phase IA 7/28/08SECTION IX

135

Learning Commons

Page 75: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

USF Polytechnic – Phase IA 7/28/08SECTION IX

136

Student Affairs/Student Academic Services Commons

Page 76: Facilities Program - University of South Floridausfweb2.usf.edu/LakelandBOT/content/docs/facilities... · Web viewfacilities Program – phase ia USF Polytechnic facilities Program

FACILITIES PROGRAM – PHASE IA USF Polytechnic

USF Polytechnic – Phase IA 7/28/08SECTION IX

137

ERDC Data Closet Interconnects